0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BXRE-35E1000-C-73

BXRE-35E1000-C-73

  • 厂商:

    BRIDGELUX

  • 封装:

    -

  • 描述:

    LEDCOBV103500KSQUARE

  • 数据手册
  • 价格&库存
BXRE-35E1000-C-73 数据手册
Bridgelux Gen 7 V10 Array Series ® Product Data Sheet DS100 1 V Series Introduction The V Series™ LED Array products deliver high quality light in a compact and cost-effective solid-state lighting package. These chip on board (CoB) arrays can be efficiently driven at twice the nominal drive current, enabling design flexibility not previously possible. This high flux density light source is designed to support a wide range of high quality, low cost directional luminaires and replacement lamps for commercial and residential applications. The V10 LED array is available in a variety of electrical, CCT and CRI combinations providing substantial design flexibility and energy efficiencies. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and longer service life. Typical applications include, replacement lamps, and task, accent, spot, track, wide area, security, wall pack and down lights. Bridgelux Décor Series is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and H Series™. Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 93, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen. Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. Features Benefits • Efficacy of 167 lm/W typical • Enhanced optical control • Compact high flux density light source • Clean white light without pixilation • Uniform high quality illumination • High quality true color reproduction • Minimum 65, 70, 80 and 90 and 95 CRI options • Significantly reduced thermal resistance and increased operating temperatures • Streamlined thermal path • ENERGY STAR® / ANSI compliant color binning structure with 2, 3 and 4 SDCM options • Uniform consistent white light • Lower operating costs • More energy efficient than incandescent, halogen and fluorescent lamps • Easy to use with daylight and motion detectors to enable increased energy savings • Low voltage DC operation • Reduced maintenance costs • Instant light with unlimited dimming • Environmentally friendly, no disposal issue • Vf bin code backside marking Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 8 Electrical Characteristics 14 Eye Safety 15 Absolute Maximum Ratings 16 Performance Curves 17 Typical Radiation Pattern 20 Typical Color Spectrum 21 Mechanical Dimensions 22 Color Binning Information 23 Packaging and Labeling 24 Design Resources 26 Precautions 26 Disclaimers 26 About Bridgelux 25 1 Product Feature Map Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series arrays are the most compact chip-on-board devices across all of Bridgelux’s LED Array products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series family of products. Polarity symbols Designed to comply with global safety standards for creepage and clearance distances Fully engineered substrate for consistent thermal, mechanical and optical properties White ring around LES Yellow phosphor Light Emitting Surface (LES) Case Temperature (Tc) Measurement Point Solder Pads Note: Part number and lot codes are scribed on back of array Product Nomenclature The part number designation for Bridgelux V Series LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 BXRE – 30 E 100 0 – C – 7 3 CCT Bin Options Product Family Nominal CCT 20 = 2,000K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K Gen. 7 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Array Configuration CRI B = 63 CRI typ. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Décor Series Showcase Target Flux Indicator 100x = 1000 lm 2 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) BXRE-20B1000-B-73 2000 65 BXRE-27E1000-B-7x 2700 80 CRI2 Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) 270 1439 1266 34.8 9.5 152 270 1458 1283 34.8 9.4 155 Nominal Drive Current3 (mA) Typical Efficacy (lm/W) BXRE-27E1000-C-7x 2700 80 360 1944 1711 34.8 12.5 155 BXRE-27G10H0-B-7x 2700 90 270 1249 1099 34.8 9.4 133 BXRE-27G10H0-C-7x 2700 90 360 1665 1465 34.8 12.5 133 BXRE-27G1000-B-7x 2700 90 270 1203 1059 34.8 9.4 128 BXRE-27G1000-C-7x 2700 90 360 1604 1412 34.8 12.5 128 BXRE-27H1000-B-7x 2700 97 270 1066 938 34.8 9.4 113 173 BXRE-30C1001-B-74 3000 70 270 1622 1428 34.8 9.4 BXRE-30C1001-C-74 3000 70 360 2163 1904 34.8 12.5 173 BXRE-30E1000-B-7x 3000 80 270 1549 1363 34.8 9.4 165 BXRE-30E1000-C-7x 3000 80 360 2066 1818 34.8 12.5 165 BXRE-30G10H0-B-7x 3000 90 270 1312 1155 34.8 9.4 140 BXRE-30G10H0-C-7x 3000 90 360 1750 1540 34.8 12.5 140 BXRE-30G1000-B-7x 3000 90 270 1258 1107 34.8 9.4 134 BXRE-30G1000-C-7x 3000 90 360 1677 1476 34.8 12.5 134 BXRE-30G100C-B-73 3000 90 270 1212 1067 34.8 9.4 129 BXRE-30G100C-C-73 3000 90 360 1616 1422 34.8 12.5 129 BXRE-30A1001-B-738,9 3000 93 270 1130 995 34.8 9.4 120 BXRE-30A1001-C-738,9 3000 93 360 1507 1326 34.8 12.5 120 BXRE-30H1000-B-7x 3000 97 270 1139 1003 34.8 9.4 121 BXRE-35E1000-B-7x 3500 80 270 1586 1396 34.8 9.4 169 BXRE-35E1000-C-7x 3500 80 360 2114 1861 34.8 12.5 169 BXRE-35G1000-B-7x 3500 90 270 1303 1147 34.8 9.4 139 BXRE-35G1000-C-7x 3500 90 360 1738 1529 34.8 12.5 139 BXRE-35A1001-B-738,9 3500 93 270 1203 1059 34.8 9.4 128 BXRE-35A1001-C-73 3500 93 360 1604 1412 34.8 12.5 128 BXRE-40C1001-B-74 4000 70 270 1668 1468 34.8 9.4 178 8,9 BXRE-40C1001-C-74 4000 70 360 2224 1957 34.8 12.5 178 BXRE-40E1000-B-7x 4000 80 270 1595 1404 34.8 9.4 170 BXRE-40E1000-C-7x 4000 80 360 2127 1871 34.8 12.5 170 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-40G1000-B-7x 4000 90 270 1331 1171 34.8 9.4 142 BXRE-40G1000-C-7x 4000 90 360 1774 1561 34.8 12.5 142 BXRE-50C1001-B-7x 5000 70 270 1677 1476 34.8 9.4 178 BXRE-50C1001-C-7x 5000 70 360 2236 1968 34.8 12.5 178 BXRE-50E1001-B-7x 5000 80 270 1613 1420 34.8 9.4 172 BXRE-50E1001-C-7x 5000 80 360 2151 1893 34.8 12.5 172 BXRE-50G1001-B-7x 5000 90 270 1394 1227 34.8 9.4 148 BXRE-50G1001-C-7x 5000 90 360 1859 1636 34.8 12.5 148 174 BXRE-57C1001-B-7x 5700 70 270 1631 1436 34.8 9.4 BXRE-57C1001-C-7x 5700 70 360 2175 1914 34.8 12.5 174 BXRE-57E1001-B-7x 5700 80 270 1549 1363 34.8 9.4 165 BXRE-57E1001-C-7x 5700 80 360 2066 1818 34.8 12.5 165 BXRE-65C1001-B-7x 6500 70 270 1631 1436 34.8 9.4 174 BXRE-65C1001-C-7x 6500 70 360 2175 1914 34.8 12.5 174 BXRE-65E1001-B-7x 6500 80 270 1568 1380 34.8 9.4 167 BXRE-65E1001-C-7x 6500 80 360 2090 1839 34.8 12.5 167 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 4 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-30A1001-B-73 3000 80 93 270 1051 925 34.3 9.3 113 BXRE-30A1001-C-73 3000 80 93 360 1401 1233 34.3 12.3 113 BXRE-35A1001-B-73 3500 80 93 270 1119 985 34.3 9.3 121 BXRE-35A1001-C-73 3500 80 93 360 1492 1313 34.3 12.3 121 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3. All CRI values are measured at Tj = Tc = 25°C. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 5 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-20B1001-B-73 2000 65 270 1295 1140 33.8 9.1 142 BXRE-27E1000-B-7x 2700 80 270 1312 1155 33.8 9.1 144 BXRE-27E1000-C-7x 2700 80 360 1750 1540 33.8 12.2 144 BXRE-27G10H0-B-7x 2700 90 270 1124 989 33.8 9.1 123 BXRE-27G10H0-C-7x 2700 90 360 1498 1319 33.8 12.2 123 BXRE-27G1000-B-7x 2700 90 270 1083 953 33.8 9.1 119 BXRE-27G1000-C-7x 2700 90 360 1444 1270 33.8 12.2 119 BXRE-27H1000-B-7x 2700 97 270 960 845 33.8 9.1 105 BXRE-30C1001-B-74 3000 70 270 1460 1285 33.8 9.1 160 BXRE-30C1001-C-74 3000 70 360 1947 1713 33.8 12.2 160 BXRE-30E1000-B-7x 3000 80 270 1394 1227 33.8 9.1 153 BXRE-30E1000-C-7x 3000 80 360 1859 1636 33.8 12.2 153 BXRE-30G10H0-B-7x 3000 90 270 1181 1039 33.8 9.1 129 BXRE-30G10H0-C-7x 3000 90 360 1575 1386 33.8 12.2 129 BXRE-30G1000-B-7x 3000 90 270 1132 996 33.8 9.1 124 BXRE-30G1000-C-7x 3000 90 360 1509 1328 33.8 12.2 124 BXRE-30G100C-B-73 3000 90 270 1091 960 33.8 9.1 120 BXRE-30G100C-C-73 3000 90 360 1455 1280 33.8 12.2 120 BXRE-30A1001-B-737,8 3000 93 270 1017 895 33.8 9.1 111 BXRE-30A1001-C-737,8 3000 93 360 1356 1193 33.8 12.2 111 BXRE-30H1000-B-7x 3000 97 270 1025 902 33.8 9.1 112 BXRE-35E1000-B-7x 3500 80 270 1427 1256 33.8 9.1 156 BXRE-35E1000-C-7x 3500 80 360 1903 1675 33.8 12.2 156 BXRE-35G1000-B-7x 3500 90 270 1173 1032 33.8 9.1 128 BXRE-35G1000-C-7x 3500 90 360 1564 1376 33.8 12.2 128 BXRE-35A1001-B-737,8 3500 93 270 1083 953 33.8 9.1 119 BXRE-35A1001-C-737,8 3500 93 360 1444 1270 33.8 12.2 119 BXRE-40C1001-B-74 4000 70 270 1501 1321 33.8 9.1 164 BXRE-40C1001-C-74 4000 70 360 2001 1761 33.8 12.2 164 BXRE-40E1000-B-7x 4000 80 270 1435 1263 33.8 9.1 157 BXRE-40E1000-C-7x 4000 80 360 1914 1684 33.8 12.2 157 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 6 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 131 BXRE-40G1000-B-7x 4000 90 270 1198 1054 33.8 9.1 BXRE-40G1000-C-7x 4000 90 360 1597 1405 33.8 12.2 131 BXRE-50C1001-B-7x 5000 70 270 1509 1328 33.8 9.1 165 BXRE-50C1001-C-7x 5000 70 360 2012 1771 33.8 12.2 165 BXRE-50E1001-B-7x 5000 80 270 1452 1278 33.8 9.1 159 BXRE-50E1001-C-7x 5000 80 360 1936 1704 33.8 12.2 159 BXRE-50G1001-B-7x 5000 90 270 1255 1104 33.8 9.1 137 BXRE-50G1001-C-7x 5000 90 360 1673 1473 33.8 12.2 137 BXRE-57C1001-B-7x 5700 70 270 1468 1292 33.8 9.1 161 BXRE-57C1001-C-7x 5700 70 360 1958 1723 33.8 12.2 161 BXRE-57E1001-B-7x 5700 80 270 1394 1227 33.8 9.1 153 BXRE-57E1001-C-7x 5700 80 360 1859 1636 33.8 12.2 153 161 BXRE-65C1001-B-7x 6500 70 270 1468 1292 33.8 9.1 BXRE-65C1001-C-7x 6500 70 360 1958 1723 33.8 12.2 161 BXRE-65E1001-B-7x 6500 80 270 1411 1242 33.8 9.1 154 BXRE-65E1001-C-7x 6500 80 360 1881 1655 33.8 12.2 154 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 7 Performance at Commonly Used Drive Currents V Series LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series LED Arrays may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1 & 2 and the flux vs. current characteristics shown in Figures 3 & 4. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI BXRE-20B1001-B-73 65 BXRE-27E1000-B-7X 80 BXRE-27E1000-C-7X 80 BXRE-27G10H0-B-7x 90 BXRE-27G10H0-C-7x 90 BXRE-27G1000-B-7x 90 BXRE-27G1000-C-7x 90 BXRE-27H1000-B-7x 97 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 4.5 6.1 9.4 14.4 19.5 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 767 1006 1439 2111 2705 777 1019 1458 2139 2741 1034 1354 1944 2831 3617 665 872 1249 1832 2347 885 1160 1665 2424 3097 641 841 1203 1765 2261 853 1117 1604 2336 2984 568 745 1066 1564 2004 689 902 1295 1878 2394 698 914 1312 1903 2426 922 1203 1750 2460 3096 598 783 1124 1630 2077 790 1030 1498 2106 2651 576 754 1083 1570 2001 761 993 1444 2029 2554 511 668 960 1392 1774 171 164 153 146 139 173 166 155 148 140 173 166 155 147 139 148 143 133 127 120 148 142 133 126 119 143 137 128 122 116 143 137 128 121 115 127 122 113 108 103 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-30C1001-B-74 70 BXRE-30C1001-C-74 70 BXRE-30E1000-B-7x 80 BXRE-30E1000-C-7x 80 BXRE-30G10H0-B-7x 90 BXRE-30G10H0-C-7x 90 BXRE-30G1000-B-7x 90 BXRE-30G1000-C-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 864 1134 1622 2380 3049 1150 1507 2163 3150 4023 826 1083 1549 2273 2912 1098 1439 2066 3008 3843 699 917 1312 1925 2467 930 1219 1750 2548 3255 670 879 1258 1845 2364 892 1168 1677 2442 3119 777 1017 1460 2117 2699 1026 1338 1947 2736 3444 742 971 1394 2022 2577 980 1278 1859 2613 3289 628 823 1181 1713 2183 830 1083 1575 2214 2786 602 788 1132 1641 2092 796 1038 1509 2121 2670 193 185 173 165 156 192 185 173 164 155 184 177 165 157 149 184 176 165 156 148 156 150 140 133 126 156 149 140 132 125 149 144 134 128 121 149 143 134 127 120 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 9 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-30G100C-B-73 90 BXRE-30G100C-C-73 90 BXRE-30A1001-B-73 93 BXRE-30A1001-C-73 93 BXRE-30H1000-B-7x 97 BXRE-35E1000-B-7x 80 BXRE-35E1000-C-7x 80 BXRE-35G1000-B-7x 90 BXRE-35G1000-C-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 646 847 1212 1778 2278 859 1126 1616 2353 3006 602 790 1130 1658 2124 801 1050 1507 2194 2803 607 796 1139 1671 2141 845 1108 1586 2327 2981 1124 1473 2114 3079 3933 695 911 1303 1912 2450 924 1210 1738 2530 3232 580 760 1091 1582 2016 767 1000 1455 2045 2573 541 708 1017 1475 1880 715 932 1356 1906 2399 546 714 1025 1487 1895 759 994 1427 2070 2638 1003 1308 1903 2675 3367 624 817 1173 1701 2168 824 1075 1564 2198 2767 144 138 129 123 117 144 138 129 122 116 134 129 120 115 109 134 129 120 114 108 135 130 121 116 110 188 181 169 161 153 188 180 169 160 151 155 149 139 132 126 155 148 139 131 124 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-35A1001-B-73 93 BXRE-35A1001-C-73 93 BXRE-40C1001-B-74 70 BXRE-40C1001-C-74 70 BXRE-40E1000-B-7x 80 BXRE-40E1000-C-7x 80 BXRE-40G1000-B-7x 90 BXRE-40G1000-C-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 641 841 1203 1765 2261 853 1117 1604 2336 2984 889 1165 1668 2447 3135 1182 1549 2224 3238 4136 850 1114 1595 2340 2998 1131 1481 2127 3097 3956 709 930 1331 1952 2501 943 1236 1774 2584 3300 576 754 1083 1570 2001 761 993 1444 2029 2554 799 1045 1501 2177 2775 1055 1376 2001 2813 3541 764 1000 1435 2082 2653 1009 1316 1914 2690 3386 637 834 1198 1737 2214 842 1098 1597 2244 2825 143 137 128 122 116 143 137 128 121 115 198 190 178 170 161 198 190 178 168 159 190 182 170 162 154 189 181 170 161 152 158 152 142 135 128 158 151 142 134 127 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-50C1001-B-7x 70 BXRE-50C1001-C-7x 70 BXRE-50E1001-B-7x 80 BXRE-50E1001-C-7x 80 BXRE-50G1001-B-7x 90 BXRE-50G1001-C-7x 90 BXRE-57C1001-B-7x 70 BXRE-57C1001-C-7x 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 894 1172 1677 2460 3152 1189 1557 2236 3256 4159 860 1127 1613 2367 3032 1144 1498 2151 3132 4001 743 974 1394 2046 2621 989 1295 1859 2707 3458 869 1140 1631 2393 3066 1156 1515 2175 3167 4046 803 1051 1509 2189 2790 1061 1384 2012 2828 3560 773 1011 1452 2105 2684 1020 1331 1936 2721 3425 668 874 1255 1820 2320 882 1150 1673 2352 2960 781 1022 1468 2129 2714 1032 1346 1958 2752 3463 199 191 178 170 161 199 191 178 169 160 192 184 172 164 155 191 184 172 163 154 166 159 148 142 134 165 159 148 141 133 194 186 174 166 157 193 186 174 165 155 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-57E1001-B-7x 80 BXRE-57E1001-C-7x 80 BXRE-65C1001-B-7x 70 BXRE-65C1001-C-7x 70 BXRE-65E1001-B-7x 80 BXRE-65E1001-C-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 135 180 270 405 540 180 240 360 540 720 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 826 1083 1549 2273 2912 1098 1439 2066 3008 3843 869 1140 1631 2393 3066 1156 1515 2175 3167 4046 835 1095 1568 2300 2946 1111 1456 2090 3044 3888 742 971 1394 2022 2577 980 1278 1859 2613 3289 781 1022 1468 2129 2714 1032 1346 1958 2752 3463 751 982 1411 2046 2608 992 1293 1881 2644 3328 184 177 165 157 149 184 176 165 156 148 194 186 174 166 157 193 186 174 165 155 186 179 167 159 151 186 178 167 158 149 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 13 Electrical Characteristics Table 5: Electrical Characteristics Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Part Number BXRE-xxx100x-B-7x BXRE-xxx100x-C-7x Drive Current (mA) Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) 0.49 30.9 38.5 -16.1 0.56 32.1 39.9 37.4 -16.1 0.37 30.9 38.5 38.8 -16.1 0.45 32.1 39.9 Minimum Typical Maximum 270 32.2 34.8 37.4 -16.1 540 33.4 36.1 38.8 360 32.2 34.8 720 33.4 36.1 Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. 14 Eye Safety Table 6: Eye Safety Risk Group (RG) Classifications Part Number BXRE-xxx100x-B-7x BXRE-xxx100x-C-7x CCT1,5 Drive Current 5 (mA) 2700K/3000K 4000K2 5000K3 6500K4 270 RG1 RG1 RG1 RG1 405 RG1 RG1 RG1 RG2 540 RG1 RG1 RG2 RG2 360 RG1 RG1 RG1 RG2 540 RG1 RG1 RG2 RG2 720 RG1 RG2 RG2 RG2 Notes for Table 6: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. 15 Absolute Maximum Ratings Table 7: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRE-xxx100x-B-7x BXRE-xxx100x-C-7x Maximum Drive Current3 540mA 720mA Maximum Peak Pulsed Drive Current4 770mA 1030mA Maximum Reverse Voltage5 -60V -60V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 16 Performance Curves Figure 1: V10B Drive Current vs. Voltage Figure 2: V10C Drive Current vs. Voltage 600 800 700 Forward Current (mA) Forward Current (mA) 500 400 300 200 100 0 600 500 400 300 200 100 32 33 34 35 36 37 0 38 32 33 34 Forward Voltage (V) 36 37 38 Figure 4: V10C Typical Relative Flux vs. Current Figure 3: V10B Typical Relative Flux vs. Current 200% 200% 180% 180% 160% 160% 140% 140% Relative Luminous Flux Relative Luminous Flux 35 Forward Voltage (V) 120% 100% 80% 60% 120% 100% 80% 60% 40% 40% 20% 20% 0% 0% 0 100 200 300 Forward Current (mA) 400 500 600 0 100 200 300 400 500 600 700 800 Forward Current (mA) Notes for Figures 1-4: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 17 Performance Curves Figure 5: Typical DC Flux vs. Case Temperature5 103% 0 Warm White Cool White 50 75 100 125 0.000 25°C Pulsed 97% 25 0.003 Neutral White 100% -0.003 94% ccy Shift Relative Luminous Flux Figure 6: Typical DC ccy Shift vs. Case Temperature 91% -0.006 88% -0.009 85% -0.012 Warm White 82% 0 25 50 75 100 125 -0.015 Neutral White Cool White 25°C Pulsed Case Temperature (°C) Case Temperature (°C) Figure 7: Typical DC ccx Shift vs. Case Temperature 0 25 50 75 100 125 0.000 -0.002 ccx Shift -0.004 -0.006 -0.008 Warm White -0.010 -0.012 Neutral White Cool White 25°C Pulsed Case Temperature (°C) Notes for Figures 5-7: 1. Characteristics shown for warm white based on 3000K and 80 CRI. 2. Characteristics shown for neutral white based on 4000K and 80 CRI. 3. Characteristics shown for cool white based on 5000K and 70 CRI. 4. Characteristics shown for warm white includes Decor Series Class A 5. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information. 18 Performance Curves Figure 8: 2000K, 65 CRI Color Shift vs. Case Temperature Figure 9: 3000K, 90 CRI Color Shift vs. Case Temperature1,3 0.403 0.4101 0.41 0.4099 0.4098 15°C 0.4097 45°C 0.4 45°C ccy ccy Pulsed Center Point Tc=25°C 25°C 0.401 25°C 0.4096 0.4095 65°C 0.399 65°C 0.398 0.4094 85°C 0.4093 0.397 85°C 0.4092 0.526 0.527 0.528 0.529 0.53 0.531 105°C 0.396 105°C 0.4091 0.409 0.525 15°C 0.402 Pulsed Center Point Tc=25°C 0.395 0.444 0.532 0.4445 0.445 0.4455 0.446 0.4465 0.447 ccx ccx Figure 10: 2700K, 97 CRI Color Shift vs. Case Temperature1 Figure 11: 3000K, 97 CRI Color Shift vs. Case Temperature1 0.4110 0.4050 15°C Pulsed Center Point Tc = 25°C 0.4100 25°C 25°C 0.4090 45°C 0.4010 45°C ccy ccy 0.4080 Pulsed Center Point Tc = 25°C 15°C 0.4030 0.4070 65°C 70°C 0.3990 0.4060 85°C 85°C 0.4050 0.3970 105°C 0.4040 105°C 0.4030 0.457 0.3950 0.4323 0.4572 0.4574 0.4576 0.4578 0.4328 0.4333 ccx 0.4343 0.4348 0.4353 ccx Figure 12: 3000K Class A Color Shift vs. Case Temperature1 Figure 13: 3500K Class A Color Shift vs. Case Temperature1 0.37 0.369 15°C 0.368 25°C 0.367 0.366 15°C Pulsed Center Point Tc=25°C 0.368 25°C 0.366 45°C Pulsed Center Point Tc=25°C 45°C 0.365 ccy ccy 0.4338 0.458 0.364 0.364 70°C 0.363 70°C 0.362 85°C 85°C 0.362 0.361 0.36 0.416 0.36 105°C 0.4165 105°C 0.417 ccx 0.4175 0.418 0.4185 0.358 0.392 0.393 0.394 0.395 0.396 0.397 ccx Note for Figures 8-13: 1. Measurements made under DC test conditions at the nominal drive current. 2. Typical color shift is shown with a tolerance of ±0.002. 3. Characteristics shown for Decor Series Showcase products, BXRE-30G100C-x-73 19 Typical Radiation Pattern Figure 14: Typical Spatial Radiation Pattern Note for Figure 14: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value. Figure 15: Typical Polar Radiation Pattern 20 Typical Color Spectrum Figure 16: Typical Color Spectrum 110% 3000K 100% 4000K 5000K Relative Spectral Power Distribution 90% 6500K 80% 70% 60% 50% 40% 30% 20% 10% 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 16: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. Figure 17: Typical Color Spectrum for Décor Series 1 20B 27H 0.9 30H 30G (Décor Series Showcase) Relative Spectral Power Distribution 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 400 450 500 550 600 Wavelength (nm) 650 700 750 800 Note for Figure 17: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 21 Mechanical Dimensions Figure 18: Drawing for V10 LED Array Notes for Figure 18: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Solder pad labeled “+” denotes positive contact. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 22 Color Binning Information Figure 19: Warm and Neutral White Test Bins in xy Color Figure 20: Cool White Test Bins in xy Color Space Space 0.39 0.44 4 SDCM 3 SDCM 2000K 3SDCM 2 SDCM 0.42 3 SDCM 0.38 2700K 0.37 5000K 3000K 0.36 3500K 0.4 5700K 0.35 Y Y 4000K 0.34 0.38 6500K 0.33 0.36 0.32 0.31 0.34 0.36 0.39 0.42 0.45 X 0.48 0.51 0.54 0.3 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 2000K 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.5280, 0.4100) (0.4578, 0.4101) (0.4338, 0.403) (0.4465, 0.4024)2 (0.4073, 0.3917) (0.3818, 0.3797) Note for Table 8: 1. Color Binning information excludes Décor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5481K - 5829K) (6270K - 6765K) 73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (6250K - 6745K) Center Point (x,y) (0.3447, 0.3553) (0.3287, 0.3417) (0.3123, 0.3282) 23 Packaging and Labeling Figure 21: V10 Packaging Tube Notes for Figure 21: 1. Each tube holds 30 V10 COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. 4. Dimensions for each tube are 8.3 (W) x 15.4 (H) x 430 (L). Dimensions for the anti-static bag are 75 (W) x 615 (L) x 3.1 (T) mm. Dimensions for the shipping box are 58.7 x 13.3 x 7.9 cm 24 Packaging and Labeling Figure 22: Gen. 7 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E4000C 73 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 25 Design Resources Application Notes 3D CAD Models Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com. Three dimensional CAD models depicting the product outline of all Bridgelux V Series LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. Optical Source Models LM80 Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. Precautions CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN101 for additional information. CAUTION: RISK OF BURN Do not touch the V Series LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Disclaimers MINOR PRODUCT CHANGE POLICY STANDARD TEST CONDITIONS The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Unless otherwise stated, array testing is performed at the nominal drive current. 26 About Bridgelux: Bridging Light and Life™ At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com © 2016-2019 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. V Bridgelux Gen 7 V10 Array Series Product Data Sheet DS100 Rev. N (03/2019) 27
BXRE-35E1000-C-73 价格&库存

很抱歉,暂时无法提供与“BXRE-35E1000-C-73”相匹配的价格&库存,您可以联系我们找货

免费人工找货