0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BXRC-30E2000-D-72

BXRC-30E2000-D-72

  • 厂商:

    BRIDGELUX

  • 封装:

    -

  • 描述:

    LEDCOBVERO133000KROUND

  • 数据手册
  • 价格&库存
BXRC-30E2000-D-72 数据手册
Bridgelux Gen 7 Vero 13 Array ® ® Product Data Sheet DS91 1 Vero® Series Introduction Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and minimum R9 value of 93, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is also designed as a replacement for halogen lamps. Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. Features • Efficacy of 160 lm/W typical • Lumen output performance ranges from 460 to 7,300 lumens • Broad range of CCT options from 2700K to 6500K • CRI options include; minimum 70, 80, and 90 • 2 and 3 SDCM color control for 2700K-4000K CCT • Reliable operation at up to 2X nominal drive current • Radial die pattern and improved lumen density • Thermally isolated solder pads • Onboard connector port • Top side part number markings • Vf bin code backside marking Benefits • Broad application coverage for interior and exterior lighting • Flexibility for application driven lighting design requirements • High quality true color reproduction • Uniform consistent white light • Flexibility in design optimization • Enhanced ease of use and assembly • Solderless connectivity enables plug & play installation and field upgradability • Improved inventory management and quality control Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 10 Electrical Characteristics 19 Eye Safety 20 Absolute Maximum Ratings 21 Performance Curves 22 Typical Radiation Pattern 25 Typical Color Spectrum 26 Mechanical Dimensions 27 Color Binning Information 28 Packaging and Labeling 29 Design Resources 31 Precautions 31 Disclaimers 31 About Bridgelux 32 1 Product Feature Map Vero 13 is the second smallest form factor in the Vero family of the next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. 2D Bar code provides full manufacturing traceability Thermally isolated solder pads reduce manufacturing cycle time and complexity Polarity indication marks simplify manufacturing operator instructions Tc Measurement point Optics location/mounting features Correlates to the true case temperature on the back surface of the LED array Mounting holes Radial die configuration improves lumen density and beam control Zhaga Book 3 compatible mounting locations Top side part number marking improves inventory management and outgoing quality control Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Optional Molex Pico-EZmate™ connector harness (sold separately) Product Nomenclature The part number designation for Bridgelux Vero LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 BXRC – 30 E 200 0 – C – 7 3 CCT Bin Options Product Family Nominal CCT 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K Gen. 7 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Array Configuration CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Flux Indicator 200x = 2000 lm 2 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E2000-B-7x 2700 80 450 2403 2163 34.8 15.7 153 BXRC-27E2000-C-7x 2700 80 630 3365 3028 34.8 21.9 153 BXRC-27E2000-D-7x 2700 80 500 2440 2196 31.8 15.9 153 BXRC-27G20H0-B-7x 2700 90 450 2083 1875 34.8 15.7 133 BXRC-27G20H0-C-7x 2700 90 630 2916 2624 34.8 21.9 133 BXRC-27G20H0-D-7x 2700 90 500 2115 1903 31.8 15.9 133 BXRC-27G2000-B-7x 2700 90 450 2000 1800 34.8 15.7 128 BXRC-27G2000-C-7x 2700 90 630 2800 2520 34.8 21.9 128 BXRC-27G2000-D-7x 2700 90 500 2031 1828 31.8 15.9 128 BXRC-27H2000-B-7x 2700 97 450 1742 1568 34.8 15.7 111 BXRC-27H2000-C-7x 2700 97 630 2439 2195 34.8 21.9 111 BXRC-27H2000-D-7x 2700 97 500 1769 1592 31.8 15.9 111 BXRC-30C2001-B-74 3000 70 450 2756 2481 34.8 15.7 176 176 BXRC-30C2001-C-74 3000 70 630 3859 3473 34.8 21.9 BXRC-30C2001-D-74 3000 70 500 2798 2519 31.8 15.9 176 BXRC-30E2000-B-7x 3000 80 450 2500 2250 34.8 15.7 160 BXRC-30E2000-C-7x 3000 80 630 3500 3150 34.8 21.9 160 BXRC-30E2000-D-7x 3000 80 500 2538 2285 31.8 15.9 160 BXRC-30G20H0-B-7x 3000 90 450 2177 1959 34.8 15.7 139 BXRC-30G20H0-C-7x 3000 90 630 3047 2743 34.8 21.9 139 BXRC-30G20H0-D-7x 3000 90 500 2210 1989 31.8 15.9 139 BXRC-30G2000-B-7x 3000 90 450 2081 1873 34.8 15.7 133 BXRC-30G2000-C-7x 3000 90 630 2913 2622 34.8 21.9 133 BXRC-30G2000-D-7x 3000 90 500 2113 1901 31.8 15.9 133 BXRC-30G200C-B-73 3000 90 450 1947 1752 35.0 15.8 124 BXRC-30G200C-D-73 3000 90 500 1965 1769 31.8 15.9 124 BXRC-30H2000-B-7x 3000 97 450 1855 1669 34.8 15.7 118 BXRC-30H2000-C-7x 3000 97 630 2597 2337 34.8 21.9 118 BXRC-30H2000-D-7x 3000 97 500 1883 1695 31.8 15.9 118 BXRC-30A2001-B-738,9 3000 93 450 1879 1691 34.8 15.7 120 BXRC-30A2001-C-738,9 3000 93 630 2631 2368 34.8 21.9 120 BXRC-30A2001-D-738,9 3000 93 500 1908 1717 31.8 15.9 120 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E2000-B-7x 3500 80 450 2581 2323 34.8 15.7 165 BXRC-35E2000-C-7x 3500 80 630 3613 3252 34.8 21.9 165 BXRC-35E2000-D-7x 3500 80 500 2620 2358 31.8 15.9 165 BXRC-35G2000-B-7x 3500 90 450 2145 1931 34.8 15.7 137 BXRC-35G2000-C-7x 3500 90 630 3003 2703 34.8 21.9 137 BXRC-35G2000-D-7x 3500 90 500 2178 1960 31.8 15.9 137 BXRC-35A2001-B-738,9 3500 93 450 2020 1818 34.8 15.7 129 BXRC-35A2001-C-738,9 3500 93 630 2828 2545 34.8 21.9 129 BXRC-35A2001-D-73 3500 93 500 2051 1846 31.8 15.9 129 BXRC-40C2001-B-74 4000 70 450 2803 2523 34.8 15.7 179 179 8,9 BXRC-40C2001-C-74 4000 70 630 3924 3532 34.8 21.9 BXRC-40C2001-D-74 4000 70 500 2846 2561 31.8 15.9 179 BXRC-40E2000-B-7x 4000 80 450 2597 2337 34.8 15.7 166 BXRC-40E2000-C-7x 4000 80 630 3636 3272 34.8 21.9 166 BXRC-40E2000-D-7x 4000 80 500 2637 2373 31.8 15.9 166 BXRC-40G2000-B-7x 4000 90 450 2226 2003 34.8 15.7 142 BXRC-40G2000-C-7x 4000 90 630 3116 2805 34.8 21.9 142 BXRC-40G2000-D-7x 4000 90 500 2260 2034 31.8 15.9 142 BXRC-40H2000-B-73 4000 97 450 1911 1719 34.8 15.7 122 BXRC-40H2000-C-73 4000 97 630 2675 2407 34.8 21.9 122 BXRC-40H2000-D-73 4000 97 500 1940 1746 31.8 15.9 122 BXRC-40A2001-B-738,9 4000 93 450 2161 1945 34.8 15.7 138 BXRC-40A2001-C-738,9 4000 93 630 3026 2723 34.8 21.9 138 BXRC-40A2001-D-738,9 4000 93 500 2194 1975 31.8 15.9 138 BXRC-50C2001-B-7x 5000 70 450 2855 2569 34.8 15.7 182 BXRC-50C2001-C-7x 5000 70 630 3997 3597 34.8 21.9 182 BXRC-50C2001-D-7x 5000 70 500 2899 2609 31.8 15.9 182 BXRC-50E2001-B-7x 5000 80 450 2678 2410 34.8 15.7 171 BXRC-50E2001-C-7x 5000 80 630 3749 3374 34.8 21.9 171 BXRC-50E2001-D-7x 5000 80 500 2719 2447 31.8 15.9 171 BXRC-50G2001-B-7x 5000 90 450 2274 2047 34.8 15.7 145 BXRC-50G2001-C-7x 5000 90 630 3184 2866 34.8 21.9 145 BXRC-50G2001-D-7x 5000 90 500 2309 2078 31.8 15.9 145 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 4 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C2001-B-7x 5700 70 450 2758 2482 34.8 15.7 176 176 BXRC-57C2001-C-7x 5700 70 630 3861 3475 34.8 21.9 BXRC-57C2001-D-7x 5700 70 500 2800 2520 31.8 15.9 176 BXRC-57E2001-B-7x 5700 80 450 2647 2382 34.8 15.7 169 BXRC-57E2001-C-7x 5700 80 630 3705 3335 34.8 21.9 169 BXRC-57E2001-D-7x 5700 80 500 2687 2418 31.8 15.9 169 BXRC-65C2001-B-7x 6500 70 450 2807 2526 34.8 15.7 179 BXRC-65C2001-C-7x 6500 70 630 3929 3536 34.8 21.9 179 BXRC-65C2001-D-7x 6500 70 500 2850 2565 31.8 15.9 179 BXRC-65E2001-B-7x 6500 80 450 2694 2424 34.8 15.7 172 BXRC-65E2001-C-7x 6500 80 630 3771 3394 34.8 21.9 172 BXRC-65E2001-D-7x 6500 80 500 2735 2461 31.8 15.9 172 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 5 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 113 BXRC-30A2001-B-73 3000 80 93 450 1748 1573 34.4 15.5 BXRC-30A2001-C-73 3000 80 93 630 2447 2202 34.4 21.6 113 BXRC-30A2001-D-73 3000 80 93 500 1774 1597 31.2 15.6 114 121 BXRC-35A2001-B-73 3500 80 93 450 1879 1691 34.4 15.5 BXRC-35A2001-C-73 3500 80 93 630 2630 2367 34.4 21.6 121 BXRC-35A2001-D-73 3500 80 93 500 1908 1717 31.2 15.6 122 BXRC-40A2001-B-73 4000 80 93 450 2010 1809 34.4 15.5 130 BXRC-40A2001-C-73 4000 80 93 630 2814 2532 34.4 21.6 130 BXRC-40A2001-D-73 4000 80 93 500 2041 1837 31.2 15.6 131 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E2000-B-7x 2700 80 450 2163 1947 33.9 15.3 142 BXRC-27E2000-C-7x 2700 80 630 3028 2725 33.9 21.4 142 BXRC-27E2000-D-7x 2700 80 500 2196 1977 30.9 15.5 142 BXRC-27G20H0-B-7x 2700 90 450 1875 1687 33.9 15.3 123 BXRC-27G20H0-C-7x 2700 90 630 2624 2362 33.9 21.4 123 BXRC-27G20H0-D-7x 2700 90 500 1903 1713 30.9 15.5 123 BXRC-27G2000-B-7x 2700 90 450 1800 1620 33.9 15.3 118 BXRC-27G2000-C-7x 2700 90 630 2520 2268 33.9 21.4 118 BXRC-27G2000-D-7x 2700 90 500 1828 1645 30.9 15.5 118 BXRC-27H2000-B-7x 2700 97 450 1568 1411 33.9 15.3 103 BXRC-27H2000-C-7x 2700 97 630 2195 1975 33.9 21.4 103 BXRC-27H2000-D-7x 2700 97 500 1592 1433 30.9 15.5 103 BXRC-30C2001-B-74 3000 70 450 2481 2232 33.9 15.3 163 BXRC-30C2001-C-74 3000 70 630 3473 3125 33.9 21.4 163 BXRC-30C2001-D-74 3000 70 500 2519 2267 30.9 15.5 163 BXRC-30E2000-B-7x 3000 80 450 2250 2025 33.9 15.3 147 BXRC-30E2000-C-7x 3000 80 630 3150 2835 33.9 21.4 147 BXRC-30E2000-D-7x 3000 80 500 2285 2056 30.9 15.5 148 BXRC-30G20H0-B-7x 3000 90 450 1959 1763 33.9 15.3 128 BXRC-30G20H0-C-7x 3000 90 630 2743 2468 33.9 21.4 128 BXRC-30G20H0-D-7x 3000 90 500 1989 1790 30.9 15.5 129 BXRC-30G2000-B-7x 3000 90 450 1873 1685 33.9 15.3 123 BXRC-30G2000-C-7x 3000 90 630 2622 2360 33.9 21.4 123 BXRC-30G2000-D-7x 3000 90 500 1901 1711 30.9 15.5 123 BXRC-30G200C-B-73 3000 90 450 1752 1577 34.1 15.3 114 BXRC-30G200C-D-73 3000 90 500 1769 1592 30.9 15.5 114 BXRC-30H2000-B-7x 3000 97 450 1669 1502 33.9 15.3 109 BXRC-30H2000-C-7x 3000 97 630 2337 2103 33.9 21.4 109 BXRC-30H2000-D-7x 3000 97 500 1695 1526 30.9 15.5 110 BXRC-30A2001-B-7x 7,8 3000 93 450 1691 1522 33.9 15.3 111 BXRC-30A2001-C-7x7,8 3000 93 630 2368 2131 33.9 21.4 111 BXRC-30A2001-D-7x7,8 3000 93 500 1717 1545 30.9 15.5 111 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 7 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E2000-B-7x 3500 80 450 2323 2090 33.9 15.3 152 BXRC-35E2000-C-7x 3500 80 630 3252 2927 33.9 21.4 152 BXRC-35E2000-D-7x 3500 80 500 2358 2122 30.9 15.5 152 BXRC-35G2000-B-7x 3500 90 450 1931 1738 33.9 15.3 127 BXRC-35G2000-C-7x 3500 90 630 2703 2433 33.9 21.4 127 BXRC-35G2000-D-7x 3500 90 500 1960 1764 30.9 15.5 127 BXRC-35A2001-B-737,8 3500 93 450 1818 1636 33.9 15.3 119 BXRC-35A2001-C-737,8 3500 93 630 2545 2291 33.9 21.4 119 BXRC-35A2001-D-737,8 3500 93 500 1846 1661 30.9 15.5 119 BXRC-40C2001-B-74 4000 70 450 2523 2271 33.9 15.3 165 BXRC-40C2001-C-74 4000 70 630 3532 3179 33.9 21.4 165 BXRC-40C2001-D-74 4000 70 500 2561 2305 30.9 15.5 166 BXRC-40E2000-B-7x 4000 80 450 2337 2103 33.9 15.3 153 BXRC-40E2000-C-7x 4000 80 630 3272 2945 33.9 21.4 153 BXRC-40E2000-D-7x 4000 80 500 2373 2136 30.9 15.5 153 BXRC-40G2000-B-7x 4000 90 450 2003 1803 33.9 15.3 131 BXRC-40G2000-C-7x 4000 90 630 2805 2524 33.9 21.4 131 BXRC-40G2000-D-7x 4000 90 500 2034 1831 30.9 15.5 132 BXRC-40H2000-B-73 4000 97 450 1719 1548 33.9 15.3 113 BXRC-40H2000-C-73 4000 97 630 2407 2167 33.9 21.4 113 BXRC-40H2000-D-73 4000 97 500 1746 1571 30.9 15.5 113 BXRC-40A2001-B-737,8 4000 93 450 1945 1750 33.9 15.3 127 BXRC-40A2001-C-737,8 4000 93 630 2723 2451 33.9 21.4 127 BXRC-40A2001-D-737,8 4000 93 500 1975 1777 30.9 15.5 128 BXRC-50C2001-B-7x 5000 70 450 2569 2313 33.9 15.3 168 BXRC-50C2001-C-7x 5000 70 630 3597 3238 33.9 21.4 168 BXRC-50C2001-D-7x 5000 70 500 2609 2348 30.9 15.5 169 BXRC-50E2001-B-7x 5000 80 450 2410 2169 33.9 15.3 158 BXRC-50E2001-C-7x 5000 80 630 3374 3036 33.9 21.4 158 BXRC-50E2001-D-7x 5000 80 500 2447 2202 30.9 15.5 158 BXRC-50G2001-B-7x 5000 90 450 2047 1842 33.9 15.3 134 BXRC-50G2001-C-7x 5000 90 630 2866 2579 33.9 21.4 134 BXRC-50G2001-D-7x 5000 90 500 2078 1870 30.9 15.5 134 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 8 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C2001-B-7x 5700 70 450 2482 2234 33.9 15.3 163 BXRC-57C2001-C-7x 5700 70 630 3475 3128 33.9 21.4 163 BXRC-57C2001-D-7x 5700 70 500 2520 2268 30.9 15.5 163 BXRC-57E2001-B-7x 5700 80 450 2382 2144 33.9 15.3 156 BXRC-57E2001-C-7x 5700 80 630 3335 3001 33.9 21.4 156 BXRC-57E2001-D-7x 5700 80 500 2418 2177 30.9 15.5 156 BXRC-65C2001-B-7x 6500 70 450 2526 2273 33.9 15.3 166 BXRC-65C2001-C-7x 6500 70 630 3536 3183 33.9 21.4 166 BXRC-65C2001-D-7x 6500 70 500 2565 2308 30.9 15.5 166 BXRC-65E2001-B-7x 6500 80 450 2424 2182 33.9 15.3 159 BXRC-65E2001-C-7x 6500 80 630 3394 3054 33.9 21.4 159 BXRC-65E2001-D-7x 6500 80 500 2461 2215 30.9 15.5 159 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 9 Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI BXRC-27E2000-B-7x 80 BXRC-27E2000-C-7x 80 BXRC-27E2000-D-7x 80 BXRC-27G20H0-B-7x 90 BXRC-27G20H0-C-7x 90 BXRC-27G20H0-D-7x 90 BXRC-27G2000-B-7x 90 BXRC-27G2000-C-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 655 1267 2403 3473 4430 909 1760 3365 4829 6164 646 1252 2440 3448 4409 567 1098 2083 3010 3839 788 1525 2916 4185 5342 560 1085 2115 2988 3821 545 1054 2000 2890 3687 757 1465 2800 4019 5130 600 1149 2163 3042 3805 859 1657 3028 4515 5743 617 1193 2196 3267 4167 520 996 1875 2636 3298 745 1436 2624 3913 4977 535 1034 1903 2831 3611 499 956 1800 2531 3167 715 1379 2520 3757 4779 175 166 153 144 136 174 164 153 143 135 175 165 153 139 128 152 143 133 125 118 151 142 133 124 117 152 143 133 120 111 146 138 128 120 113 145 137 128 119 113 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27G2000-D-7x 90 BXRC-27H2000-B-7x 97 BXRC-27H2000-C-7x 97 BXRC-27H2000-D-7x 97 BXRC-30C2001-B-74 70 BXRC-30C2001-C-74 70 BXRC-30C2001-D-74 70 BXRC-30E2000-B-7x 80 BXRC-30E2000-C-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 538 1042 2031 2870 3669 474 918 1742 2517 3211 659 1276 2439 3500 4468 468 908 1769 2499 3196 751 1453 2756 3983 5081 1043 2018 3859 5538 7069 741 1436 2798 3955 5056 681 1318 2500 3613 4609 946 1831 3500 5024 6412 513 993 1828 2719 3468 435 833 1568 2205 2758 623 1201 2195 3272 4163 447 864 1592 2368 3020 688 1318 2481 3488 4364 986 1901 3473 5177 6586 707 1368 2519 3746 4778 624 1195 2250 3164 3959 894 1724 3150 4697 5974 146 137 128 115 107 127 120 111 105 99 126 119 111 104 98 127 120 111 100 93 201 190 176 166 156 199 188 176 164 155 201 189 176 159 147 182 172 160 150 142 181 171 160 149 141 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30E2000-D-7x 80 BXRC-30G20H0-B-7x 90 BXRC-30G20H0-C-7x 90 BXRC-30G20H0-D-7x 90 BXRC-30G2000-B-7x 90 BXRC-30G2000-C-7x 90 BXRC-30G2000-D-7x 90 BXRC-30G200C-B-73 90 BXRC-30G200C-D-73 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 125 250 500 750 1000 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 3.7 7.6 15.9 24.9 34.4 672 1303 2538 3587 4587 593 1147 2177 3146 4013 823 1594 3047 4374 5583 585 1134 2210 3123 3993 567 1097 2081 3007 3836 787 1524 2913 4181 5336 559 1084 2113 2985 3817 530 1026 1947 2813 3589 520 1008 1965 2777 3551 642 1241 2285 3398 4334 543 1041 1959 2755 3447 778 1501 2743 4089 5202 559 1080 1989 2959 3774 519 995 1873 2633 3295 744 1435 2622 3909 4972 534 1033 1901 2828 3607 486 931 1752 2464 3082 497 961 1769 2631 3356 182 172 160 144 133 159 150 139 131 123 157 149 139 130 123 158 150 139 125 116 152 143 133 125 118 150 142 133 124 117 151 143 133 120 111 142 134 124 117 110 141 133 124 112 103 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30H2000-B-7x 97 BXRC-30H2000-C-7x 97 BXRC-30H2000-D-7x 97 BXRC-30A2001-B-73 93 BXRC-30A2001-C-73 93 BXRC-30A2001-D-73 93 BXRC-35E2000-B-7x 80 BXRC-35E2000-C-7x 80 BXRC-35E2000-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 505 978 1855 2681 3419 702 1358 2597 3727 4757 499 966 1883 2661 3403 512 991 1879 2716 3464 711 1376 2631 3776 4819 505 979 1908 2696 3448 703 1360 2581 3730 4757 976 1890 3613 5186 6619 694 1345 2620 3703 4735 463 887 1669 2348 2937 663 1279 2337 3485 4433 476 920 1695 2521 3216 469 898 1691 2378 2976 672 1296 2368 3530 4491 482 933 1717 2554 3258 644 1234 2323 3266 4086 923 1780 3252 4848 6167 662 1281 2358 3508 4474 135 128 118 111 105 134 127 118 111 104 135 127 118 107 99 137 129 120 113 106 136 128 120 112 106 137 129 120 108 100 188 178 165 155 146 187 176 165 154 145 188 177 165 149 138 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 13 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-35G2000-B-7x 90 BXRC-35G2000-C-7x 90 BXRC-35G2000-D-7x 90 BXRC-35A2001-B-73 93 BXRC-35A2001-C-73 93 BXRC-35A2001-D-73 93 BXRC-40C2001-B-74 70 BXRC-40C2001-C-74 70 BXRC-40C2001-D-74 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 584 1131 2145 3100 3955 811 1571 3003 4311 5502 577 1118 2178 3078 3936 550 1065 2020 2919 3724 764 1479 2828 4059 5181 543 1053 2051 2899 3706 763 1478 2803 4051 5167 1060 2053 3924 5633 7189 753 1460 2846 4022 5143 535 1026 1931 2715 3397 767 1479 2703 4030 5126 551 1065 1960 2916 3719 504 966 1818 2557 3199 722 1393 2545 3795 4827 519 1002 1846 2746 3502 700 1340 2523 3548 4438 1002 1933 3532 5266 6698 720 1391 2561 3810 4860 156 148 137 129 122 155 147 137 128 121 156 147 137 124 114 147 139 129 121 114 146 138 129 121 114 147 139 129 116 108 204 193 179 168 159 203 192 179 167 158 204 193 179 162 149 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 14 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40E2000-B-7x 80 BXRC-40E2000-C-7x 80 BXRC-40E2000-D-7x 80 BXRC-40G2000-B-7x 90 BXRC-40G2000-C-7x 90 BXRC-40G2000-D-7x 90 BXRC-40H2000-B-7x 97 BXRC-40H2000-C-7x 97 BXRC-40H2000-D-7x 97 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 707 1369 2597 3753 4787 982 1902 3636 5218 6660 698 1353 2637 3726 4764 606 1173 2226 3217 4103 842 1630 3116 4473 5709 598 1160 2260 3194 4084 520 1007 1911 2761 3522 723 1399 2675 3839 4900 513 995 1940 2741 3505 648 1242 2337 3287 4112 929 1791 3272 4878 6206 667 1289 2373 3530 4502 556 1064 2003 2817 3525 796 1535 2805 4181 5319 571 1105 2034 3026 3859 477 913 1719 2418 3025 683 1317 2407 3589 4565 490 948 1746 2597 3312 189 179 166 156 147 188 178 166 155 146 189 178 166 150 138 162 153 142 134 126 161 152 142 133 125 162 153 142 128 119 139 132 122 115 108 138 131 122 114 108 139 131 122 110 102 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 15 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40A2001-B-73 93 BXRC-40A2001-C-73 93 BXRC-40A2001-D-73 93 BXRC-50C2001-B-7x 70 BXRC-50C2001-C-7x 70 BXRC-50C2001-D-7x 70 BXRC-50E2001-B-7x 80 BXRC-50E2001-C-7x 80 BXRC-50E2001-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 589 1139 2161 3123 3984 817 1583 3026 4343 5542 581 1126 2194 3101 3965 778 1505 2855 4126 5263 1080 2091 3997 5737 7322 767 1487 2899 4096 5238 729 1411 2678 3869 4936 1013 1961 3749 5380 6867 720 1395 2719 3842 4912 539 1033 1945 2735 3422 773 1490 2723 4060 5164 555 1072 1975 2937 3747 713 1365 2569 3613 4521 1021 1969 3597 5363 6822 733 1417 2609 3881 4950 668 1280 2410 3389 4240 958 1846 3374 5030 6398 687 1329 2447 3640 4642 158 149 138 130 122 156 148 138 129 122 157 148 138 125 115 208 197 182 172 162 206 195 182 170 161 208 196 182 165 152 195 184 171 161 152 194 183 171 160 151 195 184 171 154 143 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 16 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-50G2001-B-7x 90 BXRC-50G2001-C-7x 90 BXRC-50G2001-D-7x 90 BXRC-57C2001-B-7x 70 BXRC-57C2001-C-7x 70 BXRC-57C2001-D-7x 70 BXRC-57E2001-B-7x 80 BXRC-57E2001-C-7x 80 BXRC-57E2001-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 619 1199 2274 3287 4192 860 1665 3184 4570 5833 611 1185 2309 3263 4172 751 1454 2758 3986 5084 1043 2020 3861 5542 7074 741 1437 2800 3957 5060 721 1395 2647 3825 4879 1001 1938 3705 5318 6787 711 1379 2687 3797 4855 568 1087 2047 2878 3601 813 1568 2866 4272 5435 584 1129 2078 3091 3943 688 1319 2482 3491 4367 986 1902 3475 5181 6591 708 1369 2520 3749 4782 661 1265 2382 3349 4191 946 1825 3335 4972 6324 679 1313 2418 3597 4588 166 157 145 137 129 164 155 145 136 128 165 156 145 131 121 201 190 176 166 156 199 189 176 165 155 201 189 176 159 147 193 182 169 159 150 191 181 169 158 149 193 182 169 153 141 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 17 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-65C2001-B-7x 70 BXRC-65C2001-C-7x 70 BXRC-65C2001-D-7x 70 BXRC-65E2001-B-7x 80 BXRC-65E2001-C-7x 80 BXRC-65E2001-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 764 1479 2807 4056 5174 1062 2055 3929 5640 7198 754 1462 2850 4027 5149 734 1420 2694 3893 4965 1019 1972 3771 5412 6908 724 1403 2735 3865 4942 700 1342 2526 3552 4444 1004 1935 3536 5272 6707 720 1393 2565 3815 4866 672 1288 2424 3409 4265 963 1857 3394 5060 6437 691 1337 2461 3661 4670 205 193 179 169 159 203 192 179 167 158 204 193 179 162 150 196 186 172 162 153 195 184 172 161 152 196 185 172 155 144 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 18 Electrical Characteristics Table 5: Electrical Characteristics Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Part Number BXRC-xxx200x-B-7x BXRC-xxx200x-C-7x BXRC-xxx200x-D-7x Drive Current (mA) Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) 0.28 31.0 38.3 -14.3 0.35 32.2 39.7 37.4 -14.3 0.20 31.0 38.3 36.1 38.8 -14.3 0.24 32.2 39.7 29.4 31.8 34.2 -13.3 0.34 28.4 35.0 31.8 34.4 37.0 -13.3 0.41 30.8 37.9 Minimum Typical Maximum 450 32.2 34.8 37.4 -14.3 900 33.4 36.1 38.8 630 32.2 34.8 1260 33.4 500 1000 Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. 19 Eye Safety Table 6: Eye Safety Risk Group (RG) Classifications Part Number BXRC-xxx200x-B-7x BXRC-xxx200x-C-7x BXRC-xxx200x-D-7x CCT1,5 Drive Current 5 (mA) 2700K/3000K 4000K2 5000K3 6500K4 450 RG1 RG1 RG1 RG1 675 RG1 RG1 RG1 RG2 900 RG1 RG1 RG2 RG2 630 RG1 RG1 RG1 RG1 945 RG1 RG1 RG2 RG2 1260 RG1 RG2 RG2 RG2 500 RG1 RG1 RG1 RG1 750 RG1 RG1 RG1 RG2 1000 RG1 RG1 RG2 RG2 Notes for Table 6: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. 20 Absolute Maximum Ratings Table 7: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx200x-B-7x BXRC-xxx200x-C-7x BXRC-xxx200x-D-7x Maximum Drive Current3 900mA 1260mA 1000mA Maximum Peak Pulsed Drive Current4 1290mA 1800mA 1430mA Maximum Reverse Voltage5 -60V -60V -55V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 21 Performance Curves Figure 1: Vero 13B Drive Current vs. Voltage Figure 2: Vero 13C Drive Current vs. Voltage 1000 1400 900 1200 700 Forward Current (mA) Forward Current (mA) 800 600 500 400 300 1000 800 600 400 200 200 100 0 32 33 34 35 36 37 0 38 32 33 34 Forward Voltage (V) 35 36 37 38 Forward Voltage (V) Figure 3: Vero 13D Drive Current vs. Voltage Figure 4: Vero 13B Typical Relative Flux vs. Current 200% 1100 180% 1000 160% Relative Luminous Flux Forward Current (mA) 900 800 700 600 500 400 300 120% 100% 80% 60% 40% 200 20% 100 0 140% 0% 29 30 31 32 33 34 0 35 100 200 300 200% 200% 180% 180% 160% 160% 140% 140% 120% 100% 80% 60% 850 Forward Current (mA) 900 1000 60% 20% 0% 700 800 80% 40% 550 700 100% 20% 400 600 120% 40% 250 500 Figure 6 Vero 13D Typical Relative Flux vs. Current Relative Luminous Flux Relative Luminous Flux Figure 5: Vero 13C Typical Relative Flux vs. Current 100 400 Forward Current (mA) Forward Voltage (V) 1000 1150 1300 0% 0 100 200 300 400 500 600 700 800 900 1000 1100 Forward Current (mA) Note for Figure 1-6: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 22 Performance Curves Figure 7: Typical DC Flux vs. Case Temperature 0 103% 25 50 75 100 125 0.003 Warm White Neutral White 100% Cool White 0.000 25°C Pulsed 97% -0.003 94% ccy Shift Relative Luminous Flux Figure 8: Typical DC ccy Shift vs. Case Temperature 91% -0.006 88% -0.009 85% -0.012 Warm White 82% 0 25 50 75 100 125 Case Temperature (°C) -0.015 Neutral White Cool White 25°C Pulsed Case Temperature (°C) Figure 9: Typical DC ccx Shift vs. Case Temperature 0 25 50 75 100 125 0.000 -0.002 ccx Shift -0.004 -0.006 -0.008 Warm White -0.010 -0.012 Neutral White Cool White 25°C Pulsed Case Temperature (°C) Notes for Figures 7-9: 1. Characteristics shown for warm white based on 3000K and 80 CRI. 2. Characteristics shown for neutral white based on 4000K and 80 CRI. 3. Characteristics shown for cool white based on 5000K and 70 CRI. 4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information. 23 Performance Curves Figure 10: 2700K, 97 CRI Color Shift vs. Case Temperature1 Figure 11: 3000K, 97 CRI Color Shift vs. Case Temperature1 0.4110 0.4050 15°C Pulsed Center Point Tc = 25°C 0.4100 25°C 25°C 45°C 0.4010 45°C ccy ccy 0.4080 Pulsed Center Point Tc = 25°C 15°C 0.4030 0.4090 0.4070 65°C 70°C 0.3990 0.4060 85°C 85°C 0.4050 0.3970 105°C 0.4040 105°C 0.4030 0.457 0.4572 0.4574 0.4576 0.4578 0.3950 0.4323 0.458 0.4328 0.4333 ccx Figure 12: 3000K, 90 CRI Color Shift vs. Case Temperature3 0.4343 0.369 15°C 0.402 Pulsed Center Point Tc=25°C 25°C 15°C 0.368 25°C 0.367 0.401 0.366 0.399 ccy 45°C 0.4 0.4348 0.4353 Figure 13: 3000K Class A Color Shift vs. Case Temperature1 0.403 ccy 0.4338 ccx 65°C 0.398 45°C 0.365 0.364 70°C 0.363 85°C 0.397 Pulsed Center Point Tc=25°C 85°C 0.362 105°C 0.396 0.395 0.444 0.361 0.4445 0.445 0.4455 0.446 0.4465 105°C 0.36 0.416 0.447 0.4165 0.417 ccx 0.4175 0.418 0.4185 ccx Figure 14: 3500K Class A Color Shift vs. Case Temperature1 Figure 15: 4000K Class A Color Shift vs. Case Temperature1 0.37 0.3760 15°C 0.368 25°C 0.366 Pulsed Center Point Tc=25°C 15°C 0.3740 25°C 0.3720 45°C 45°C ccy 0.3700 ccy Pulsed Center Point Tc=25°C 0.364 0.3680 70°C 0.362 70°C 0.3660 85°C 0.36 85°C 0.3640 105°C 0.358 0.392 105°C 0.393 0.394 0.395 0.396 0.397 ccx Note for Figures 10-15: 1. Measurements made under DC test conditions at the nominal drive current. 2. Typical color shift is shown with a tolerance of ±0.002. 3. Characteristics shown for Decor Series Showcase products, BXRC-30G200C-x-73 0.3620 0.373 0.374 0.375 0.376 ccx 0.377 0.378 0.379 24 Typical Radiation Pattern Figure 16: Typical Spatial Radiation Pattern Note for Figure 16: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value. Figure 17: Typical Polar Radiation Pattern 25 Typical Color Spectrum Figure 18: Typical Color Spectrum 110% 3000K 100% 4000K 5000K Relative Spectral Power Distribution 90% 6500K 80% 70% 60% 50% 40% 30% 20% 10% 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 18: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. Figure 19: Typical Color Spectrum for Vero 13 with Décor Series 1 27H 0.9 30H 30G (Décor Series Showcase) Relative Spectral Power Distribution 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 400 450 500 550 600 Wavelength (nm) 650 700 750 800 Note for Figure 19: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 26 Mechanical Dimensions Figure 20: Drawing for Vero 13 LED Array Notes for Figure 20: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Mounting holes (2X) are for M2.5 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 27 Color Binning Information Figure 21: Warm and Neutral White Test Bins in xy Color Figure 22: Cool White Test Bins in xy Color Space Space 0.44 0.39 4 SDCM 3 SDCM 3 SDCM 0.38 2 SDCM 2700K 0.42 0.37 3000K 0.4 5000K 0.36 3500K 5700K 0.35 Y Y 4000K 0.34 0.38 6500K 0.33 0.36 0.32 0.31 0.34 0.36 0.39 0.42 X 0.45 0.3 0.48 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.4578, 0.4101) (0.4338, 0.403) (0.4465, 0.4024)2 (0.4073, 0.3917) (0.3818, 0.3797) Note for Table 8: 1. Color Binning information excludes Décor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5829K - 5481K) (6270K - 6765K) 73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (6250K - 6745K) Center Point (x,y) (0.3447, 0.3553) (0.3287, 0.3417) (0.3123, 0.3282) 28 Packaging and Labeling Figure 23: Drawing for Vero 13 Packaging Tray Notes for Figure 23: 1. Dimensions are in millimeters. 2. Drawings are not to scale. 29 Packaging and Labeling Figure 24: Vero Series Packaging and Labeling Notes for Figure 24: 1. Each tray holds 100 COBs. 2. Each tray is vacuum sealed in an anti-static bag and placed in its own box. 3. Each tray, bag and box is to be labeled as shown above. Figure 25: Gen. 7 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E2000C 73 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 30 Design Resources Application Notes 3D CAD Models Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. Optical Source Models LM80 Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. Precautions CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN31 for additional information. CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. Disclaimers MINOR PRODUCT CHANGE POLICY STANDARD TEST CONDITIONS The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Unless otherwise stated, array testing is performed at the nominal drive current. 31 About Bridgelux: Bridging Light and Life™ At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com © 2016-2018 Bridgelux, Inc. All rights reserved 2018. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 7 Vero 13 Array Series Product Data Sheet DS91 Rev. N (10/2018) 32
BXRC-30E2000-D-72 价格&库存

很抱歉,暂时无法提供与“BXRC-30E2000-D-72”相匹配的价格&库存,您可以联系我们找货

免费人工找货