Bridgelux Gen 7 Vero 18 Array
®
®
Product Data Sheet DS92
1
Vero® Series
Introduction
Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light
sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four
LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents.
Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color
control standard for clean and consistent uniform lighting.
Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting
features for plug-and-play installation.
Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing unmatched
LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color points are
available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD.
Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric.
Décor Series™ Ultra products provide a high CRI of 97 and typical R9 value of 98, which emphasizes the reds and color tones
to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor
Series Ultra is designed as a replacement for halogen lamps.
Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and
restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series
Food products are a must have for any butcher counter or bakery.
Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment
industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these
industries.
Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps.
Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white
light with enhanced spectrum coverage and higher efficacy.
Features
• Efficacy of 170 lm/W typical for 3000K 80 CRI
• Lumen output performance ranges from 1,455 to
13,600 lumens
• Broad range of CCT options from 1750K to 6500K
• CRI options include minimum 65, 70, 80, 90, 95 and
Class A
Benefits
• Broad application coverage for interior and exterior
lighting
• Flexibility for application driven lighting design
requirements
• High quality true color reproduction
• Uniform consistent white light
• Reliable operation at up to 2X nominal drive current
• Flexibility in design optimization
• Radial die pattern and improved lumen density
• Enhanced ease of use and assembly
• Thermally isolated solder pads
• Solderless connectivity enables plug & play
installation and field upgradability
• Onboard connector port
• Top side part number markings
• Vf bin code backside marking
• Improved inventory management and quality control
Contents
Product Feature Map
2
Product Nomenclature
2
Product Selection Guide
3
Performance at Commonly Used Drive Currents
10
Electrical Characteristics
20
Eye Safety
21
Absolute Maximum Ratings
22
Performance Curves
23
Typical Radiation Pattern
27
Typical Color Spectrum
28
Mechanical Dimensions
29
Color Binning Information
30
Packaging and Labeling
31
Design Resources
33
Precautions
33
Disclaimers
33
About Bridgelux
34
1
Product Feature Map
Vero 18 is the second largest form factor in the Vero
family of next generation solid state light sources. In
addition to delivering the performance and light quality
required for many lighting applications, Vero incorporates
several features to simplify the design integration and
manufacturing process, accelerate time to market and
reduce system costs. Please visit www.bridgelux.com for
more information on the Vero Series family of products.
Thermally isolated solder pads reduce
manufacturing cycle time and complexity
2D Bar code provides full manufacturing traceability
Polarity indication marks simplify
manufacturing operator instructions
Tc Measurement point
Optics location/mounting features
Mounting holes
Radial die configuration improves lumen
density and beam control
Zhaga Book 3 compatible
mounting locations
Top side part number marking improves
inventory management and outgoing
quality control
Solderless connector port enables simplified
manufacturing processes, reduced inventory
carrying costs and can enable field upgradability
Optional Molex Pico-EZmate™ connector harness
(sold separately)
Product Nomenclature
The part number designation for Bridgelux Vero LED arrays is explained as follows:
1 2 3 4
5 6
7 8 9 10 11
–
12
– 13 14
BXRC – 30 E 400 0 – C – 7 3
CCT Bin Options
Product Family
Nominal CCT
17 = 1,750K
20 = 2,000K
25 = 2,500K
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
56 = 5,600K
57 = 5,700K
65 = 6,500K
Gen. 7
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
Array Configuration
CRI
B = 65 CRI min.
C = 70 CRI min.
E = 80 CRI min.
G = 90 CRI min.
H = 97 CRI typ.
A = Class A
Color Targeting Designator
0 = Cold Targeted
1 = Hot Targeted
C = Decor Series Showcase Target
Flux Indicator
400x = 4000 lm
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-17E4000-B-74
1750
80
900
2881
2593
34.8
31.3
92
BXRC-17E4000-C-74
1750
80
1170
3624
3261
34.8
40.7
89
BXRC-17E4000-D-74
1750
80
1050
2710
2439
29.0
30.5
89
157
BXRC-20B4001-C-73
2000
65
1170
6392
5753
34.8
40.7
BXRC-20B4001-D-73
2000
65
1050
4781
4303
29.0
30.5
157
BXRC-25E4000-B-74
2500
80
900
4792
4313
34.8
31.3
153
153
BXRC-25E4000-C-74
2500
80
1170
6230
5607
34.8
40.7
BXRC-25E4000-D-74
2500
80
1050
4659
4193
29.0
30.5
153
BXRC-27E4000-B-7x
2700
80
900
5011
4510
34.8
31.3
160
BXRC-27E4000-C-7x
2700
80
1170
6515
5863
34.8
40.7
160
BXRC-27E4000-D-7x
2700
80
1050
4872
4385
29.0
30.5
160
BXRC-27G40H0-B-7x
2700
90
900
4291
3862
34.8
31.3
137
BXRC-27G40H0-C-7x
2700
90
1170
5578
5020
34.8
40.7
137
BXRC-27G40H0-D-7x
2700
90
1050
4172
3754
29.0
30.5
137
BXRC-27G4000-B-7x
2700
90
900
4134
3721
34.8
31.3
132
BXRC-27G4000-C-7x
2700
90
1170
5375
4837
34.8
40.7
132
BXRC-27G4000-D-7x
2700
90
1050
4019
3617
29.0
30.5
132
BXRC-27H4000-B-7x
2700
97
900
3664
3298
34.8
31.3
117
BXRC-27H4000-C-7x
2700
97
1170
4764
4287
34.8
40.7
117
BXRC-27H4000-D-7x
2700
97
1050
3563
3206
29.0
30.5
117
BXRC-30C4001-B-74
3000
70
900
5575
5017
34.8
31.3
178
178
BXRC-30C4001-C-74
3000
70
1170
7247
6523
34.8
40.7
BXRC-30C4001-D-74
3000
70
1050
5420
4878
29.0
30.5
178
BXRC-30E4000-B-7x
3000
80
900
5324
4792
34.8
31.3
170
170
BXRC-30E4000-C-7x
3000
80
1170
6922
6230
34.8
40.7
BXRC-30E4000-D-7x
3000
80
1050
5177
4659
29.0
30.5
170
BXRC-30G40H0-B-7x
3000
90
900
4322
3890
34.8
31.3
138
BXRC-30G40H0-C-7x
3000
90
1170
5619
5057
34.8
40.7
138
BXRC-30G40H0-D-7x
3000
90
1050
4202
3782
29.0
30.5
138
BXRC-30G4000-B-7x
3000
90
900
4510
4059
34.8
31.3
144
BXRC-30G4000-C-7x
3000
90
1170
5863
5277
34.8
40.7
144
BXRC-30G4000-D-7x
3000
90
1050
4385
3946
29.0
30.5
144
BXRC-30G400C-B-73
3000
90
900
4166
3749
34.8
31.3
133
BXRC-30G400C-D-73
3000
90
1050
4050
3645
29.0
30.5
133
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary 3
depending on fixture design and performance.
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30H4000-B-7x
3000
97
900
3915
3524
34.8
31.3
125
BXRC-30H4000-C-7x
3000
97
1170
5090
4581
34.8
40.7
125
BXRC-30H4000-D-7x
3000
97
1050
3806
3426
29.0
30.5
125
BXRC-30A4001-B-738,9
3000
93
900
3884
3495
34.8
31.3
124
BXRC-30A4001-C-738,9
3000
93
1170
5049
4544
34.8
40.7
124
BXRC-30A4001-D-738,9
3000
93
1050
3776
3398
29.0
30.5
124
BXRC-35E4000-B-7x
3500
80
900
5450
4905
34.8
31.3
174
BXRC-35E4000-C-7x
3500
80
1170
7085
6376
34.8
40.7
174
BXRC-35E4000-D-7x
3500
80
1050
5298
4768
29.0
30.5
174
BXRC-35G4000-B-7x
3500
90
900
4479
4031
34.8
31.3
143
BXRC-35G4000-C-7x
3500
90
1170
5822
5240
34.8
40.7
143
BXRC-35G4000-D-7x
3500
90
1050
4354
3919
29.0
30.5
143
BXRC-35A4001-B-738,9
3500
93
900
4134
3721
34.8
31.3
132
BXRC-35A4001-C-738,9
3500
93
1170
5375
4837
34.8
40.7
132
BXRC-35A4001-D-73
3500
93
1050
4019
3617
29.0
30.5
132
BXRC-40C4001-B-74
4000
70
900
5732
5158
34.8
31.3
183
8,9
BXRC-40C4001-C-74
4000
70
1170
7451
6706
34.8
40.7
183
BXRC-40C4001-D-74
4000
70
1050
5572
5015
29.0
30.5
183
BXRC-40E4000-B-7x
4000
80
900
5481
4933
34.8
31.3
175
BXRC-40E4000-C-7x
4000
80
1170
7125
6413
34.8
40.7
175
BXRC-40E4000-D-7x
4000
80
1050
5329
4796
29.0
30.5
175
BXRC-40G4000-B-7x
4000
90
900
4573
4115
34.8
31.3
146
BXRC-40G4000-C-7x
4000
90
1170
5945
5350
34.8
40.7
146
BXRC-40G4000-D-7x
4000
90
1050
4446
4001
29.0
30.5
146
BXRC-40H4000-B-73
4000
97
900
4134
3721
34.8
31.3
132
BXRC-40H4000-C-73
4000
97
1170
5375
4837
34.8
40.7
132
BXRC-40H4000-D-73
4000
97
1050
4019
3617
29.0
30.5
132
BXRC-40A4001-B-738,9
4000
93
900
4479
4031
34.8
31.3
143
BXRC-40A4001-C-738,9
4000
93
1170
5822
5240
34.8
40.7
143
BXRC-40A4001-D-738,9
4000
93
1050
4354
3919
29.0
30.5
143
BXRC-50C4001-B-7x
5000
70
900
5763
5187
34.8
31.3
184
BXRC-50C4001-C-7x
5000
70
1170
7492
6743
34.8
40.7
184
BXRC-50C4001-D-7x
5000
70
1050
5603
5043
29.0
30.5
184
BXRC-50E4001-B-7x
5000
80
900
5544
4989
34.8
31.3
177
BXRC-50E4001-C-7x
5000
80
1170
7207
6486
34.8
40.7
177
BXRC-50E4001-D-7x
5000
80
1050
5390
4851
29.0
30.5
177
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all
other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products
is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
4
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-50G4001-B-7x
5000
90
900
4792
4313
34.8
31.3
153
BXRC-50G4001-C-7x
5000
90
1170
6230
5607
34.8
40.7
153
BXRC-50G4001-D-7x
5000
90
1050
4659
4193
29.0
30.5
153
BXRC-56G4000-B-74
5600
90
900
4823
4341
34.8
31.3
154
BXRC-56G4000-C-74
5600
90
1170
6270
5643
34.8
40.7
154
BXRC-56G400x-D-74
5600
90
1050
4689
4220
29.0
30.5
154
BXRC-56H4000-D-74
5600
97
1050
4233
3809
29.0
30.5
139
BXRC-57C4001-B-7x
5700
70
900
5606
5046
34.8
31.3
179
BXRC-57C4001-C-7x
5700
70
1170
7288
6559
34.8
40.7
179
BXRC-57C4001-D-7x
5700
70
1050
5451
4905
29.0
30.5
179
BXRC-57E4001-B-7x
5700
80
900
5324
4792
34.8
31.3
170
BXRC-57E4001-C-7x
5700
80
1170
6922
6230
34.8
40.7
170
BXRC-57E4001-D-7x
5700
80
1050
5177
4659
29.0
30.5
170
BXRC-65C4001-B-7x
6500
70
900
5606
5046
34.8
31.3
179
BXRC-65C4001-C-7x
6500
70
1170
7288
6559
34.8
40.7
179
BXRC-65C4001-D-7x
6500
70
1050
5451
4905
29.0
30.5
179
BXRC-65E4001-B-7x
6500
80
900
5387
4848
34.8
31.3
172
BXRC-65E4001-C-7x
6500
80
1170
7003
6303
34.8
40.7
172
BXRC-65E4001-D-7x
6500
80
1050
5237
4714
29.0
30.5
172
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all
other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products
is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
5
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8
Part Number
Nominal
CCT1
(K)
GAI2
CRI3
Nominal
Drive
Current4
(mA)
Typical DC
Flux5,6
Tc = 70ºC
(lm)
Minimum DC
Flux6,9
Tc = 70ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30A4001-B-73
3000
80
93
900
3612
3251
34.3
30.9
116
BXRC-30A4001-C-73
3000
80
93
1170
4695
4226
34.3
40.2
116
BXRC-30A4001-D-73
3000
80
93
1050
3511
3160
28.5
29.9
116
BXRC-35A4001-B-73
3500
80
93
900
3845
3460
34.3
30.9
123
BXRC-35A4001-C-73
3500
80
93
1170
4998
4498
34.3
40.2
123
BXRC-35A4001-D-73
3500
80
93
1050
3738
3364
28.5
29.9
123
BXRC-40A4001-B-73
4000
80
93
900
4165
3749
34.3
30.9
133
BXRC-40A4001-C-73
4000
80
93
1170
5415
4873
34.3
40.2
133
BXRC-40A4001-D-73
4000
80
93
1050
4050
3645
28.5
29.9
133
Notes for Table 2:
1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on
fixture design and performance.
3. CRI Values are specified as typical.
4. Drive current is referred to as nominal drive current.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material
and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
6
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
85
BXRC-17E4000-B-74
1750
80
900
2593
2334
33.9
30.5
BXRC-17E4000-C-74
1750
80
1170
3261
2935
33.9
39.7
82
BXRC-17E4000-D-74
1750
80
1050
2439
2195
28.1
29.5
83
BXRC-20B4001-C-73
2000
65
1170
5753
5178
33.9
39.7
145
BXRC-20B4001-D-73
2000
65
1050
4303
3872
28.1
29.5
146
BXRC-25E4000-B-74
2500
80
900
4313
3881
33.9
30.5
141
BXRC-25E4000-C-74
2500
80
1170
5607
5046
33.9
39.7
141
BXRC-25E4000-D-74
2500
80
1050
4193
3774
28.1
29.5
142
BXRC-27E4000-B-7x
2700
80
900
4510
4059
33.9
30.5
148
BXRC-27E4000-C-7x
2700
80
1170
5863
5277
33.9
39.7
148
BXRC-27E4000-D-7x
2700
80
1050
4385
3946
28.1
29.5
149
BXRC-27G40H0-B-7x
2700
90
900
3862
3476
33.9
30.5
127
BXRC-27G40H0-C-7x
2700
90
1170
5020
4518
33.9
39.7
127
BXRC-27G40H0-D-7x
2700
90
1050
3754
3379
28.1
29.5
127
BXRC-27G4000-B-7x
2700
90
900
3721
3349
33.9
30.5
122
BXRC-27G4000-C-7x
2700
90
1170
4837
4353
33.9
39.7
122
BXRC-27G4000-D-7x
2700
90
1050
3617
3256
28.1
29.5
123
BXRC-27H4000-B-7x
2700
97
900
3298
2968
33.9
30.5
108
BXRC-27H4000-C-7x
2700
97
1170
4287
3859
33.9
39.7
108
BXRC-27H4000-D-7x
2700
97
1050
3206
2886
28.1
29.5
109
164
BXRC-30C4001-B-74
3000
70
900
5017
4516
33.9
30.5
BXRC-30C4001-C-74
3000
70
1170
6523
5870
33.9
39.7
164
BXRC-30C4001-D-74
3000
70
1050
4878
4390
28.1
29.5
165
157
BXRC-30E4000-B-7x
3000
80
900
4792
4313
33.9
30.5
BXRC-30E4000-C-7x
3000
80
1170
6230
5607
33.9
39.7
157
BXRC-30E4000-D-7x
3000
80
1050
4659
4193
28.1
29.5
158
BXRC-30G40H0-B-7x
3000
90
900
3890
3501
33.9
30.5
127
BXRC-30G40H0-C-7x
3000
90
1170
5057
4551
33.9
39.7
127
BXRC-30G40H0-D-7x
3000
90
1050
3782
3404
28.1
29.5
128
133
BXRC-30G4000-B-7x
3000
90
900
4059
3653
33.9
30.5
BXRC-30G4000-C-7x
3000
90
1170
5277
4749
33.9
39.7
133
BXRC-30G4000-D-7x
3000
90
1050
3946
3552
28.1
29.5
134
BXRC-30G400C-B-73
3000
90
900
3749
3374
33.9
30.5
123
BXRC-30G400C-D-73
3000
90
1050
3645
3280
28.1
29.5
124
BXRC-30H4000-B-7x
3000
97
900
3524
3171
33.9
30.5
115
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50,
the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
7
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30H4000-C-7x
3000
97
1170
4581
4122
33.9
39.7
115
BXRC-30H4000-D-7x
3000
97
1050
3426
3083
28.1
29.5
116
BXRC-30A4001-B-738,9
3000
93
900
3495
3146
33.9
30.5
115
BXRC-30A4001-C-738,9
3000
93
1170
4544
4090
33.9
39.7
115
BXRC-30A4001-D-738,9
3000
93
1050
3398
3058
28.1
29.5
115
161
BXRC-35E4000-B-7x
3500
80
900
4905
4414
33.9
30.5
BXRC-35E4000-C-7x
3500
80
1170
6376
5739
33.9
39.7
161
BXRC-35E4000-D-7x
3500
80
1050
4768
4292
28.1
29.5
162
132
BXRC-35G4000-B-7x
3500
90
900
4031
3628
33.9
30.5
BXRC-35G4000-C-7x
3500
90
1170
5240
4716
33.9
39.7
132
BXRC-35G4000-D-7x
3500
90
1050
3919
3527
28.1
29.5
133
BXRC-35A4001-B-738,9
3500
93
900
3721
3349
33.9
30.5
122
BXRC-35A4001-C-738,9
3500
93
1170
4837
4353
33.9
39.7
122
BXRC-35A4001-D-738,9
3500
93
1050
3617
3256
28.1
29.5
123
BXRC-40C4001-B-74
4000
70
900
5158
4643
33.9
30.5
169
BXRC-40C4001-C-74
4000
70
1170
6706
6035
33.9
39.7
169
BXRC-40C4001-D-74
4000
70
1050
5015
4514
28.1
29.5
170
BXRC-40E4000-B-7x
4000
80
900
4933
4440
33.9
30.5
162
BXRC-40E4000-C-7x
4000
80
1170
6413
5771
33.9
39.7
162
BXRC-40E4000-D-7x
4000
80
1050
4796
4316
28.1
29.5
163
135
BXRC-40G4000-B-7x
4000
90
900
4115
3704
33.9
30.5
BXRC-40G4000-C-7x
4000
90
1170
5350
4815
33.9
39.7
135
BXRC-40G4000-D-7x
4000
90
1050
4001
3601
28.1
29.5
136
BXRC-40H4000-B-7x
4000
97
900
3721
3349
33.9
30.5
122
BXRC-40H4000-C-7x
4000
97
1170
4837
4353
33.9
39.7
122
BXRC-40H4000-D-7x
4000
97
1050
3617
3256
28.1
29.5
123
BXRC-40A4001-B-737,8
4000
93
900
4031
3628
33.9
30.5
132
BXRC-40A4001-C-737,8
4000
93
1170
5240
4716
33.9
39.7
132
BXRC-40A4001-D-737,8
4000
93
1050
3919
3527
28.1
29.5
133
BXRC-50C4001-B-74
5000
70
900
5187
4668
33.9
30.5
170
BXRC-50C4001-C-74
5000
70
1170
6743
6068
33.9
39.7
170
BXRC-50C4001-D-74
5000
70
1050
5043
4538
28.1
29.5
171
BXRC-50E4001-B-74
5000
80
900
4989
4490
33.9
30.5
164
BXRC-50E4001-C-74
5000
80
1170
6486
5837
33.9
39.7
164
BXRC-50E4001-D-74
5000
80
1050
4851
4366
28.1
29.5
164
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50,
the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
8
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-50G4001-B-7x
5000
90
900
4313
3881
33.9
30.5
141
BXRC-50G4001-C-7x
5000
90
1170
5607
5046
33.9
39.7
141
BXRC-50G4001-D-7x
5000
90
1050
4193
3774
28.1
29.5
142
142
BXRC-56G4000-B-74
5600
90
900
4341
3907
33.9
30.5
BXRC-56G4000-C-74
5600
90
1170
5643
5079
33.9
39.7
142
BXRC-56G400x-D-74
5600
90
1050
4220
3798
28.1
29.5
143
BXRC-56H4000-D-74
5600
97
1050
3809
3428
28.1
29.5
129
BXRC-57C4001-B-7x
5700
70
900
5046
4541
33.9
30.5
165
BXRC-57C4001-C-7x
5700
70
1170
6559
5903
33.9
39.7
165
BXRC-57C4001-D-7x
5700
70
1050
4905
4415
28.1
29.5
166
157
BXRC-57E4001-B-7x
5700
80
900
4792
4313
33.9
30.5
BXRC-57E4001-C-7x
5700
80
1170
6230
5607
33.9
39.7
157
BXRC-57E4001-D-7x
5700
80
1050
4659
4193
28.1
29.5
158
BXRC-65C4001-B-7x
6500
70
900
5046
4541
33.9
30.5
165
BXRC-65C4001-C-7x
6500
70
1170
6559
5903
33.9
39.7
165
BXRC-65C4001-D-7x
6500
70
1050
4905
4415
28.1
29.5
166
BXRC-65E4001-B-7x
6500
80
900
4848
4364
33.9
30.5
159
BXRC-65E4001-C-7x
6500
80
1170
6303
5673
33.9
39.7
159
BXRC-65E4001-D-7x
6500
80
1050
4714
4242
28.1
29.5
160
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50,
the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
9
Performance at Commonly Used Drive Currents
Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also
be driven at other drive currents dependent on specific application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current
characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4.
Table 4: Product Performance at Commonly Used Drive Currents
Part Number
CRI
BXRC-17E4000-B-7x
80
BXRC-17E4000-C-7x
80
BXRC-17E4000-D-7x
80
BXRC-20B4001-C-73
65
BXRC-20B4001-D-73
65
BXRC-25E4000-B-74
80
BXRC-25E4000-C-74
80
BXRC-25E4000-D-74
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
1488
1955
2881
4157
5241
1872
2458
3624
5228
6592
1402
1831
2710
4006
5161
3302
4336
6392
9222
11628
2474
3230
4781
7067
9104
2475
3250
4792
6913
8717
3218
4226
6230
8987
11332
2411
3148
4659
6887
8872
1360
1777
2593
3662
4504
1710
2235
3261
4606
5664
1281
1665
2439
3529
4434
3016
3942
5753
8124
9991
2260
2936
4303
6226
7822
2261
2955
4313
6090
7490
2940
3842
i102
7917
9736
2203
2862
4193
6067
7623
100
96
92
86
81
96
93
89
84
78
96
93
89
84
78
170
163
157
147
137
170
163
157
147
137
166
159
153
144
134
166
159
153
144
134
166
159
153
144
134
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
10
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27E4000-B-7x
80
BXRC-27E4000-C-7x
80
BXRC-27E4000-D-7x
80
BXRC-27G40H0-B-7x
90
BXRC-27G40H0-C-7x
90
BXRC-27G40H0-D-7x
90
BXRC-27G4000-B-7x
90
BXRC-27G4000-C-7x
90
BXRC-27G4000-D-7x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
2588
3399
5011
7230
9116
3365
4419
6515
9399
11850
2521
3292
4872
7202
9277
2216
2911
4291
6190
7805
2881
3784
5578
8048
10147
2159
2818
4172
6167
7944
2135
2804
4134
5965
7520
2776
3646
5375
7754
9776
2080
2716
4019
5942
7654
2365
3090
4510
6369
7832
3074
4017
5863
8280
10182
2303
2993
4385
6345
7971
2025
2646
3862
5453
6706
2632
3440
5020
7089
8718
1972
2562
3754
5433
6825
1951
2550
3721
5254
6462
2536
3314
4837
6831
8400
1900
2469
3617
5234
6576
173
167
160
150
140
173
167
160
150
140
173
167
160
150
140
148
143
137
129
120
148
143
137
129
120
148
143
137
129
120
143
137
132
124
116
143
137
132
124
116
143
137
132
124
116
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
11
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27H4000-B-7x
97
BXRC-27H4000-C-7x
97
BXRC-27H4000-D-7x
97
BXRC-30C4001-B-74
70
BXRC-30C4001-C-74
70
BXRC-30C4001-D-74
70
BXRC-30E4000-B-7x
80
BXRC-30E4000-C-7x
80
BXRC-30E4000-D-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
1893
2486
3664
5287
6666
2460
3231
4764
6873
8665
1844
2407
3563
5267
6784
2879
3782
5575
8043
10141
3743
4916
7247
10456
13183
2805
3662
5420
8013
10321
2750
3612
5324
7682
9685
3575
4695
6922
9986
12591
2679
3497
5177
7653
9857
1729
2260
3298
4657
5727
2248
2938
4287
6054
7446
1684
2188
3206
4640
5829
2631
3438
5017
7085
8713
3420
4469
6523
9211
11327
2563
3329
4878
7059
8868
2512
3283
4792
6767
8322
3266
4269
6230
8797
10818
2447
3180
4659
6741
8470
127
122
117
110
102
127
122
117
110
102
127
122
117
110
102
193
185
178
167
156
193
185
178
167
156
193
185
178
167
156
184
177
170
160
149
184
177
170
160
149
184
177
170
160
149
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
12
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30G40H0-B-7x
90
BXRC-30G40H0-C-7x
90
BXRC-30G40H0-D-7x
90
BXRC-30G4000-B-7x
90
BXRC-30G4000-C-7x
90
BXRC-30G4000-D-7x
90
BXRC-30G400C-B-73
90
BXRC-30G400C-D-73
BXRC-30H4000-B-7x
90
97
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
525
700
1050
1575
2100
450
600
900
1350
1800
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
2232
2932
4322
6236
7862
2902
3811
5619
8106
10221
2175
2839
4202
6212
8002
2329
3059
4510
6507
8204
3028
3977
5863
8459
10665
2269
2962
4385
6482
8350
2152
2826
4166
6010
7577
2096
2736
4050
5987
7712
2022
2656
3915
5648
7122
2040
2665
3890
5493
6755
2651
3465
5057
7141
8782
1987
2581
3782
5472
6875
2128
2781
4059
5732
7049
2767
3616
5277
7452
9164
2073
2693
3946
5710
7174
1966
2569
3749
5294
6511
1915
2488
3645
5274
6626
1847
2414
3524
4976
6119
149
144
138
130
121
149
144
138
130
121
149
144
138
130
121
156
150
144
135
126
156
150
144
135
126
156
150
144
135
126
144
138
133
125
116
144
138
133
125
116
135
130
125
117
109
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
13
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30H4000-C-7x
97
BXRC-30H4000-D-7x
97
BXRC-30A4001-B-73
93
BXRC-30A4001-C-73
93
BXRC-30A4001-D-73
93
BXRC-35E4000-B-7x
80
BXRC-35E4000-C-7x
80
BXRC-35E4000-D-7x
80
BXRC-35G4000-B-7x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.3
33.9
35.0
36.7
38.0
33.4
34.0
35.0
36.8
38.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
15.0
20.4
31.2
49.5
68.4
19.5
26.5
40.6
64.5
89.3
14.6
19.8
30.4
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
2629
3452
5090
7343
9258
1970
2572
3806
5627
7248
2006
2634
3884
5603
7065
2608
3425
5049
7284
9184
1954
2551
3776
5582
7190
2815
3697
5450
7862
9913
3659
4806
7085
10221
12887
2742
3580
5298
7833
10089
2313
3038
4479
6462
8147
2402
3139
4581
6468
7955
1800
2338
3426
4957
6228
1833
2395
3495
4936
6070
2382
3114
4544
6417
7891
1785
2319
3398
4917
6178
2572
3361
4905
6926
8518
3343
4369
6376
9004
11073
2505
3254
4768
6900
8669
2113
2762
4031
5692
7000
135
130
125
117
109
135
130
125
117
109
134
129
124
113
103
134
129
124
113
103
134
129
124
116
109
188
181
174
163
152
188
181
174
163
152
188
181
174
163
152
155
149
143
134
125
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
14
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-35G4000-C-7x
90
BXRC-35G4000-D-7x
90
BXRC-35A4001-B-73
80
BXRC-35A4001-C-73
80
BXRC-35A4001-D-73
80
BXRC-40C4001-B-74
80
BXRC-40C4001-C-74
80
BXRC-40C4001-D-74
80
BXRC-40E4000-B-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
3007
3949
5822
8400
10591
2253
2942
4354
6437
8292
2135
2804
4134
5965
7520
2776
3646
5375
7754
9776
2080
2716
4019
5942
7654
2960
3888
5732
8269
10426
3848
5054
7451
10750
13554
2884
3765
5572
8238
10611
2831
3718
5481
7908
9970
2747
3591
5240
7400
9100
2059
2675
3919
5671
7124
1951
2550
3721
5254
6462
2536
3314
4837
6831
8400
1900
2469
3617
5234
6576
2705
3535
5158
7284
8958
3516
4595
6706
9470
11646
2635
3423
5015
7257
9117
2586
3380
4933
6966
8566
155
149
143
134
125
155
149
143
134
125
143
137
132
124
116
143
137
132
124
116
143
137
132
124
116
198
191
183
172
160
198
191
183
172
160
198
191
183
172
160
189
182
175
164
153
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
15
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40E4000-C-7x
80
BXRC-40E4000-D-7x
80
BXRC-40G4000-B-7x
90
BXRC-40G4000-C-7x
90
BXRC-40G4000-D-7x
90
BXRC-40H4000-B-7x
97
BXRC-40H4000-C-7x
97
BXRC-40H4000-D-7x
97
BXRC-40A4001-B-73
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
3680
4833
7125
10280
12961
2758
3600
5329
7878
10147
2362
3102
4573
6597
8318
3070
4032
5945
8576
10813
2301
3004
4446
6572
8466
2135
2804
4134
5965
7520
2776
3646
5375
7754
9776
2080
2716
4019
5942
7654
2313
3038
4479
6462
8147
3362
4394
6413
9056
11136
2519
3273
4796
6940
8719
2158
2820
4115
5812
7147
2805
3666
5350
7555
9291
2102
2731
4001
5790
7274
1951
2550
3721
5254
6462
2536
3314
4837
6831
8400
1900
2469
3617
5234
6576
2113
2762
4031
5692
7000
189
182
175
164
153
189
182
175
164
153
158
152
146
137
128
158
152
146
137
128
158
152
146
137
128
143
137
132
124
116
143
137
132
124
116
143
137
132
124
116
155
149
143
134
125
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
16
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40A4001-C-73
80
BXRC-40A4001-D-73
80
BXRC-50C4001-B-74
70
BXRC-50C4001-C-74
70
BXRC-50C4001-D-74
70
BXRC-50E4001-B-74
80
BXRC-50E4001-C-7x
80
BXRC-50E4001-D-7x
80
BXRC-50G4001-B-7x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
3007
3949
5822
8400
10591
2253
2942
4354
6437
8292
2977
3909
5763
8314
10483
3869
5082
7492
10808
13628
2899
3785
5603
8283
10669
2863
3760
5544
7998
10084
3722
4888
7207
10397
13109
2789
3641
5390
7968
10263
2475
3250
4792
6913
8717
2747
3591
5240
7400
9100
2059
2675
3919
5671
7124
2719
3554
5187
7324
9007
3535
4620
6743
9521
11709
2649
3441
5043
7297
9167
2616
3419
4989
7046
8664
3401
4444
6486
9159
11264
2548
3311
4851
7019
8818
2261
2955
4313
6090
7490
155
149
143
134
125
155
149
143
134
125
199
192
184
173
161
199
192
184
173
161
199
192
184
173
161
192
184
177
166
155
192
184
177
166
155
192
184
177
166
155
166
159
153
144
134
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
17
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-50G4001-C-7x
90
BXRC-50G4001-D-7x
90
BXRC-56G4000-B-74
90
BXRC-56G4000-C-74
90
BXRC-56G400x-D-74
90
BXRC-56H4000-D-74
97
BXRC-57C4001-B-7x
70
BXRC-57C4001-C-7x
70
BXRC-57C4001-D-7x
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
3218
4226
6230
8987
11332
2411
3148
4659
6887
8872
2491
3272
4823
6959
8774
3239
4253
6270
9046
11406
2427
3168
4689
6932
8930
2190
2860
4233
6257
8060
2896
3803
5606
8088
10198
3764
4944
7288
10515
13257
2821
3682
5451
8058
10379
2940
3842
5607
7917
9736
2203
2862
4193
6067
7623
2276
2974
4341
6130
7539
2959
3867
5643
7969
9800
2217
2880
4220
6107
7672
2001
2600
3809
5512
6925
2646
3457
5046
7125
8762
3439
4495
6559
9263
11391
2577
3348
4905
7098
8918
166
159
153
144
134
166
159
153
144
134
167
160
154
145
135
167
160
154
145
135
167
160
154
145
135
150
145
139
131
122
194
186
179
168
157
194
186
179
168
157
194
186
179
168
157
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
18
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-57E4001-B-7x
80
BXRC-57E4001-C-7x
80
BXRC-57E4001-D-7x
80
BXRC-65C4001-B-7x
70
BXRC-65C4001-C-7x
70
BXRC-65C4001-D-7x
70
BXRC-65E4001-B-7x
80
BXRC-65E4001-C-7x
80
BXRC-65E4001-D-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
27.7
28.2
29.0
30.4
31.5
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
14.9
20.4
31.3
48.1
65.1
19.4
26.5
40.7
62.5
84.6
14.6
19.8
30.5
47.9
66.2
2750
3612
5324
7682
9685
3575
4695
6922
9986
12591
2679
3497
5177
7653
9857
2896
3803
5606
8088
10198
3764
4944
7288
10515
13257
2821
3682
5451
8058
10379
2782
3654
5387
7772
9799
3617
4750
7003
10104
12739
2710
3538
5237
7743
9973
2512
3283
4792
6767
8322
3266
4269
6230
8797
10818
2447
3180
4659
6741
8470
2646
3457
5046
7125
8762
3439
4495
6559
9263
11391
2577
3348
4905
7098
8918
2542
3322
4848
6847
8420
3305
4319
6303
8901
10946
2476
3217
4714
6821
8569
184
177
170
160
149
184
177
170
160
149
184
177
170
160
149
194
186
179
168
157
194
186
179
168
157
194
186
179
168
157
186
179
172
162
151
186
179
172
162
151
186
179
172
162
151
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
19
Electrical Characteristics
Table 5: Electrical Characteristics
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8
Part Number
BXRC-xxx400x-B-7x
BXRC-xxx400x-C-7x
BXRC-xxx400x-D-7x
Drive Current
(mA)
Typical
Coefficient
of Forward
Voltage4
∆Vf/∆Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
0.15
31.0
38.4
-14.9
0.19
32.2
39.8
37.4
-14.9
0.11
31.0
38.4
36.1
38.8
-14.9
0.13
32.2
39.8
26.8
29.0
31.2
-12.2
0.16
25.8
32.0
29.2
31.5
33.9
-12.2
0.19
28.2
34.7
Minimum
Typical
Maximum
900
32.2
34.8
37.4
-14.9
1800
33.4
36.1
38.8
1170
32.2
34.8
2340
33.4
1050
2100
Notes for Table 5:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface
material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and
selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The
working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product
application.
20
Eye Safety
Table 6: Eye Safety Risk Group (RG) Classifications
Part Number
BXRC-xxx400x-B-7x
BXRC-xxx400x-C-7x
BXRC-xxx400x-D-7x
CCT1,5
Drive
Current 5
(mA)
2700K/3000K
4000K2
5000K3
6500K4
900
RG1
RG1
RG1
RG1
1350
RG1
RG1
RG1
RG2
1800
RG1
RG1
RG2
RG2
1170
RG1
RG1
RG1
RG1
1755
RG1
RG1
RG2
RG2
2340
RG1
RG1
RG2
RG2
1050
RG1
RG1
RG1
RG1
1575
RG1
RG1
RG1
RG2
2100
RG1
RG1
RG2
RG2
Notes for Table 6:
1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the
assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx.
3. For products classified as RG2 at 5000K Ethr= 1315.8 lx.
4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
21
Absolute Maximum Ratings
Table 7: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
150°C
Storage Temperature
-40°C to +105°C
Operating Case Temperature1 (Tc)
105°C
Soldering Temperature2
300°C or lower for a maximum of 6 seconds
BXRC-xxx400x-B-7x
BXRC-xxx400x-C-7x
BXRC-xxx400x-D-7x
Maximum Drive Current3
1800mA
2340mA
2100mA
Maximum Peak Pulsed Drive Current4
2570mA
3340mA
3000mA
Maximum Reverse Voltage5
-60V
-60V
-50V
Notes for Table 7:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays.
3. Arrays may be driven at higher currents however lumen maintenance may be reduced.
4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
22
Performance Curves
Figure 2: Vero 18C Drive Current vs. Voltage
2000
2700
1800
2400
1600
2100
1400
Forward Current (mA)
Forward Current (mA)
Figure 1: Vero 18B Drive Current vs. Voltage
1200
1000
800
600
1800
1500
1200
900
600
400
300
200
0
32
33
34
35
36
37
38
0
39
32
33
34
200%
2000
180%
1750
160%
1500
140%
Relative Luminous Flux
Forward Current (mA)
2250
1250
1000
750
500
38
39
100%
80%
60%
40%
20%
26
27
28
29
30
31
0%
32
0
200
400
600
Forward Voltage (V)
800
1000
1200
1400
1600
1800
2000
Forward Current (mA)
Figure 5: Vero 18C Typical Relative Flux vs. Current
Figure 6 Vero 18D Typical Relative Flux vs. Current
y = -7E-08x + 0.001x + 0.027
2
200%
200%
180%
180%
160%
160%
140%
140%
Relative Luminous Flux
Relative Luminous Flux
37
120%
250
120%
100%
80%
60%
40%
120%
100%
80%
60%
40%
20%
0%
36
Figure 4: Vero 18B Typical Relative Flux vs. Current
Figure 3: Vero 18D Drive Current vs. Voltage
0
35
Forward Voltage (V)
Forward Voltage (V)
20%
100
400
700
1000
1300
1600
Forward Current (mA)
1900
2200
2500
0%
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
Forward Current (mA)
Notes for Figures 1-6:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
23
Performance Curves
Figure 8: Typical DC ccy Shift vs. Case Temperature
Figure 7: Typical DC Flux vs. Case Temperature
103%
Neutral White
100%
25°C Pulsed
25
50
75
100
125
-0.003
94%
91%
-0.006
-0.009
88%
Warm White
-0.012
85%
82%
0
0.000
Cool White
97%
ccy Shift
Relative Luminous Flux
0.003
Warm White
-0.015
0
25
50
75
100
125
Neutral White
Cool White
25°C Pulsed
Case Temperature (°C)
Case Temperature (°C)
Figure 9: Typical DC ccx Shift vs. Case Temperature
0.000
0
25
50
75
100
125
-0.002
ccx Shift
-0.004
-0.006
-0.008
Warm White
-0.010
-0.012
Neutral White
Cool White
25°C Pulsed
Case Temperature (°C)
Notes for Figures 7-9:
1. Characteristics shown for warm white based on 3000K and 80 CRI.
2. Characteristics shown for neutral white based on 4000K and 80 CRI.
3. Characteristics shown for cool white based on 5000K and 70 CRI.
4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.
24
Performance Curves
Figure 11: 2000K, 65 CRI Color Shift vs. Case Temperature
Figure 10: 1750K Color Shift vs. Case Temperature1
0.3705
0.37
0.4101
Pulsed Center Point
Tc = 25°C
15°C
0.41
0.4099
25°C
0.4098
Pulsed Center
Point Tc=25°C
15°C
25°C
0.4097
0.3695
0.369
ccy
ccy
45°C
45°C
0.4096
0.4095
65°C
0.4094
70°C
0.4093
85°C
85°C
0.4092
0.3685
105°C
0.368
0.5196
105°C
0.4091
0.5198
0.52
0.5202
0.5204
0.409
0.525
0.5206
0.526
0.527
0.528
Figure 12: 2500K Color Shift vs. Case Temperature1
25°C
0.4135
0.413
Pulsed
Center Point
Tc = 25°C
0.532
0.4125
0.399
85°C
0.397
105°C
0.396
0.47
65°C
0.398
85°C
0.4105
0.468
45°C
0.4
70°C
0.4115
Pulsed Center
Point Tc=25°C
25°C
0.401
45°C
0.412
15°C
0.402
ccy
ccy
0.531
0.403
15°C
0.414
0.472
0.474
0.476
0.395
0.444
0.478
105°C
0.4445
0.445
0.4455
Figure 14: 2700K, 97 CRI Color Shift vs. Case Temperature1
0.446
0.4465
0.447
ccx
ccx
Figure 15: 3000K, 97 CRI Color Shift vs. Case Temperature1
0.4110
0.4050
15°C
Pulsed Center
Point
Tc = 25°C
0.4100
25°C
0.4080
Pulsed Center
Point
Tc = 25°C
15°C
0.4030
25°C
0.4090
45°C
0.4010
45°C
ccy
ccy
0.53
Figure 13: 3000K, 90 CRI Color Shift vs. Case Temperature1,3
0.4145
0.411
0.529
ccx
ccx
0.4070
65°C
70°C
0.3990
0.4060
85°C
85°C
0.4050
0.3970
105°C
0.4040
105°C
0.4030
0.457
0.4572
0.4574
0.4576
0.4578
0.458
ccx
Note for Figures 10-15:
1. Measurements made under DC test conditions at the nominal drive current.
2. Typical color shift is shown with a tolerance of ±0.002.
3. Characteristics shown for Decor Series Showcase products, BXRC-30G400C-x-73
0.3950
0.4323
0.4328
0.4333
0.4338
0.4343
0.4348
0.4353
ccx
25
Performance Curves
Figure 16: 5600K Color Shift vs. Case Temperature1,3
Figure 17: 3000K Class A Color Shift vs. Case Temperature1
0.344
0.369
15°C
0.342
0.34
25°C
0.338
0.367
0.332
70°C
0.33
0.365
0.364
70°C
0.363
85°C
0.328
Pulsed
Center Point
Tc=25°C
45°C
45°C
0.334
ccy
ccy
25°C
0.366
0.336
0.326
0.368
Pulsed Center
Point
Tc = 25°C
15°C
85°C
0.362
105°C
0.361
0.324
0.322
0.32
0.322
0.324
0.326
0.328
105°C
0.36
0.416
0.33
0.4165
0.417
ccx
Figure 18: 3500K Class A Color Shift vs. Case Temperature1
ccx
0.4175
0.418
0.4185
Figure 19: 4000K Class A Color Shift vs. Case Temperature1
0.37
0.3760
15°C
0.368
Pulsed
Center Point
Tc=25°C
25°C
0.366
15°C
0.3740
25°C
0.3720
45°C
45°C
ccy
0.3700
ccy
Pulsed
Center Point
Tc=25°C
0.364
0.3680
70°C
0.362
85°C
0.3660
0.36
85°C
0.3640
105°C
0.358
0.392
70°C
105°C
0.393
0.394
0.395
0.396
0.397
ccx
0.3620
0.373
0.374
0.375
0.376
ccx
0.377
0.378
0.379
Note for Figures 16-19:
1. Measurements made under DC test conditions at the nominal drive current.
2. Typical color shift is shown with a tolerance of ±0.002.
3. Color shift shown for product hot targeted at Tc=85°C
26
Typical Radiation Pattern
Figure 20: Typical Spatial Radiation Pattern
Note for Figure 20:
1. Typical viewing angle is 120⁰.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
Figure 21: Typical Polar Radiation Pattern
27
Typical Color Spectrum
Figure 22: Typical Color Spectrum
110%
3000K
100%
4000K
5000K
Relative Spectral Power Distribution
90%
6500K
80%
70%
60%
50%
40%
30%
20%
10%
0%
400
450
500
550
600
650
700
750
800
Wavelength (nm)
Note for Figure 22:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
2. Color spectra shown is 3000K and 80 CRI.
3. Color spectra shown is 4000K and 80 CRI.
4. Color spectra shown is 5000K and 70 CRI.
4. Color spectra shown is 6500K and 70 CRI.
Figure 23: Typical Color Spectrum for Vero 18 with Décor Series
1
17E
20B
0.9
25E
27H
30G (Décor Series Showcase)
0.8
30H
Relative Spectral Power Distribution
56G
56H
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
400
450
500
550
600
Wavelength (nm)
650
700
750
800
Note for Figure 23:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
28
Mechanical Dimensions
Figure 24: Drawing for Vero 18 LED Array
Notes for Figure 24:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ±0.1mm.
4. Mounting holes (2X) are for M2.5 screws.
5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing.
6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat,
countersink, or raised head screws.
7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively.
8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used
depending on application specific design requirements.
9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations.
10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
29
Color Binning Information
Figure 25: Warm and Neutral White Test Bins in xy Color Space
0.44
2500K
4SDCM
3 SDCM
4 SDCM
2000K
3SDCM
2700K
0.42
3000K
3500K
0.4
Y
4000K
1750K
4SDCM
0.38
0.36
0.34
0.36
0.39
0.42
0.45
X
0.48
0.51
0.54
Note: Pulsed Test Conditions, Tc = 25°C
Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT
Bin Code
1750K
2000K
2500K
2700K
3000K1
3500K1
4000K1
ANSI Bin
(for reference only)
-
-
-
(2580K - 2870K)
(2870K - 3220K)
(3220K - 3710K)
(3710K - 4260K)
73 (3 SDCM)
-
-
-
(2651K - 2794K)
(2968K - 3136K)
(3369K - 3586K)
(3851K - 4130K)
72 (2 SDCM)
-
-
-
(2674K - 2769K)
(2995K - 3107K)
(3404K - 3548K)
(3895K - 4081K)
Center Point (x,y)
(0.5167, 0.366)
(0.5280, 0.4100)
(0.4765, 0.4137)
(0.4578, 0.4101)
(0.4338, 0.403)
(0.4465, 0.4024)2
(0.4073, 0.3917)
(0.3818, 0.3797)
Note for Table 8:
1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information.
2. Center Point for Decor Series Showcase.
Figure 26: Cool White Test Bins in xy Color Space
0.39
4 SDCM
3 SDCM
0.38
0.37
5000K
0.36
5700K
Y
0.35
0.34
6500K
0.33
0.32
0.31
0.3
0.3
0.31
0.32
0.33
0.34
0.35
0.36
X
Note: Pulsed Test Conditions, Tc = 25°C
Note: Pulsed Test Conditions, Tc = 25°C
Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)
Bin Code
5000K
5600K
5700K
6500K
ANSI Bin (for reference only)
(4745K - 5311K)
(5310K - 6020K)
(5312K - 6022K)
(6022K - 7042K)
74 (4 SDCM)
(4801K - 5282K)
(5475K - 5830K)
(5481K - 5829K)
(6270K - 6765K)
73 (3 SDCM)
(4835K - 5215K)
(5490K - 5820K)
(5490K - 5820K)
(6250K - 6745K)
Center Point (x,y)
(0.3447, 0.3553)
(0.3293, 0.3423)
(0.3287, 0.3417)
(0.3123, 0.3282)
Note for Table 9:
1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C.
30
Packaging and Labeling
Figure 27: Drawing for Vero 18 Packaging Tray
Notes for Figure 27:
1. Dimensions are in millimeters.
2. Drawings are not to scale.
31
Packaging and Labeling
Figure 28: Vero Series Packaging and Labeling
Notes for Figure 28:
1. Each tray holds 100 COBs.
2. Each tray is vacuum sealed in an anti-static bag and placed in its own box.
3. Each tray, bag and box is to be labeled as shown above.
Figure 29: Gen. 7 Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number
30E4000C 73 2F
Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin code
definitions.
32
Design Resources
Application Notes
3D CAD Models
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the Vero
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Three dimensional CAD models depicting the product
outline of all Bridgelux Vero LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
Optical Source Models
LM80
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales representative for LM-80 report.
Precautions
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN31 for additional information.
CAUTION: RISK OF BURN
Do not touch the Vero LED array during operation. Allow
the array to cool for a sufficient period of time before
handling. The Vero LED array may reach elevated
temperatures such that could burn skin when touched.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area). Optical
devices may be mounted on the top surface of the
plastic housing of the Vero LED array. Use the
mechanical features of the LED array housing, edges
and/or mounting holes to locate and secure optical
devices as needed.
Disclaimers
MINOR PRODUCT CHANGE POLICY
STANDARD TEST CONDITIONS
The rigorous qualification testing on products offered
by Bridgelux provides performance assurance. Slight
cosmetic changes that do not affect form, fit, or function
may occur as Bridgelux continues product optimization.
Unless otherwise stated, array testing is performed
at the nominal drive current.
33
About Bridgelux: Bridging Light and Life™
At Bridgelux, we help companies, industries and people experience the power and possibility
of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient,
cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and
financial. And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux-inc-_2
WeChat ID: BridgeluxInChina
46430 Fremont Boulevard
Fremont, CA 94538 U.S.A.
Tel (925) 583-8400
www.bridgelux.com
© 2016-2019 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and
V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.
Bridgelux Gen 7 Vero 18 Array Series Product Data Sheet DS92 Rev. Q (09/2020)
34