0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BXRC-30G4000-C-72

BXRC-30G4000-C-72

  • 厂商:

    BRIDGELUX

  • 封装:

    -

  • 描述:

    LEDCOBVERO183000KROUND

  • 数据手册
  • 价格&库存
BXRC-30G4000-C-72 数据手册
Bridgelux Gen 7 Vero 18 Array ® ® Product Data Sheet DS92 1 Vero® Series Introduction Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and typical R9 value of 98, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen lamps. Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series Food products are a must have for any butcher counter or bakery. Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these industries. Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. Features • Efficacy of 170 lm/W typical for 3000K 80 CRI • Lumen output performance ranges from 1,455 to 13,600 lumens • Broad range of CCT options from 1750K to 6500K • CRI options include minimum 65, 70, 80, 90, 95 and Class A Benefits • Broad application coverage for interior and exterior lighting • Flexibility for application driven lighting design requirements • High quality true color reproduction • Uniform consistent white light • Reliable operation at up to 2X nominal drive current • Flexibility in design optimization • Radial die pattern and improved lumen density • Enhanced ease of use and assembly • Thermally isolated solder pads • Solderless connectivity enables plug & play installation and field upgradability • Onboard connector port • Top side part number markings • Vf bin code backside marking • Improved inventory management and quality control Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 10 Electrical Characteristics 20 Eye Safety 21 Absolute Maximum Ratings 22 Performance Curves 23 Typical Radiation Pattern 27 Typical Color Spectrum 28 Mechanical Dimensions 29 Color Binning Information 30 Packaging and Labeling 31 Design Resources 33 Precautions 33 Disclaimers 33 About Bridgelux 34 1 Product Feature Map Vero 18 is the second largest form factor in the Vero family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. Thermally isolated solder pads reduce manufacturing cycle time and complexity 2D Bar code provides full manufacturing traceability Polarity indication marks simplify manufacturing operator instructions Tc Measurement point Optics location/mounting features Mounting holes Radial die configuration improves lumen density and beam control Zhaga Book 3 compatible mounting locations Top side part number marking improves inventory management and outgoing quality control Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Optional Molex Pico-EZmate™ connector harness (sold separately) Product Nomenclature The part number designation for Bridgelux Vero LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 BXRC – 30 E 400 0 – C – 7 3 CCT Bin Options Product Family Nominal CCT 17 = 1,750K 20 = 2,000K 25 = 2,500K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 56 = 5,600K 57 = 5,700K 65 = 6,500K Gen. 7 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Array Configuration CRI B = 65 CRI min. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Flux Indicator 400x = 4000 lm 2 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-17E4000-B-74 1750 80 900 2881 2593 34.8 31.3 92 BXRC-17E4000-C-74 1750 80 1170 3624 3261 34.8 40.7 89 BXRC-17E4000-D-74 1750 80 1050 2710 2439 29.0 30.5 89 157 BXRC-20B4001-C-73 2000 65 1170 6392 5753 34.8 40.7 BXRC-20B4001-D-73 2000 65 1050 4781 4303 29.0 30.5 157 BXRC-25E4000-B-74 2500 80 900 4792 4313 34.8 31.3 153 153 BXRC-25E4000-C-74 2500 80 1170 6230 5607 34.8 40.7 BXRC-25E4000-D-74 2500 80 1050 4659 4193 29.0 30.5 153 BXRC-27E4000-B-7x 2700 80 900 5011 4510 34.8 31.3 160 BXRC-27E4000-C-7x 2700 80 1170 6515 5863 34.8 40.7 160 BXRC-27E4000-D-7x 2700 80 1050 4872 4385 29.0 30.5 160 BXRC-27G40H0-B-7x 2700 90 900 4291 3862 34.8 31.3 137 BXRC-27G40H0-C-7x 2700 90 1170 5578 5020 34.8 40.7 137 BXRC-27G40H0-D-7x 2700 90 1050 4172 3754 29.0 30.5 137 BXRC-27G4000-B-7x 2700 90 900 4134 3721 34.8 31.3 132 BXRC-27G4000-C-7x 2700 90 1170 5375 4837 34.8 40.7 132 BXRC-27G4000-D-7x 2700 90 1050 4019 3617 29.0 30.5 132 BXRC-27H4000-B-7x 2700 97 900 3664 3298 34.8 31.3 117 BXRC-27H4000-C-7x 2700 97 1170 4764 4287 34.8 40.7 117 BXRC-27H4000-D-7x 2700 97 1050 3563 3206 29.0 30.5 117 BXRC-30C4001-B-74 3000 70 900 5575 5017 34.8 31.3 178 178 BXRC-30C4001-C-74 3000 70 1170 7247 6523 34.8 40.7 BXRC-30C4001-D-74 3000 70 1050 5420 4878 29.0 30.5 178 BXRC-30E4000-B-7x 3000 80 900 5324 4792 34.8 31.3 170 170 BXRC-30E4000-C-7x 3000 80 1170 6922 6230 34.8 40.7 BXRC-30E4000-D-7x 3000 80 1050 5177 4659 29.0 30.5 170 BXRC-30G40H0-B-7x 3000 90 900 4322 3890 34.8 31.3 138 BXRC-30G40H0-C-7x 3000 90 1170 5619 5057 34.8 40.7 138 BXRC-30G40H0-D-7x 3000 90 1050 4202 3782 29.0 30.5 138 BXRC-30G4000-B-7x 3000 90 900 4510 4059 34.8 31.3 144 BXRC-30G4000-C-7x 3000 90 1170 5863 5277 34.8 40.7 144 BXRC-30G4000-D-7x 3000 90 1050 4385 3946 29.0 30.5 144 BXRC-30G400C-B-73 3000 90 900 4166 3749 34.8 31.3 133 BXRC-30G400C-D-73 3000 90 1050 4050 3645 29.0 30.5 133 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary 3 depending on fixture design and performance. Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30H4000-B-7x 3000 97 900 3915 3524 34.8 31.3 125 BXRC-30H4000-C-7x 3000 97 1170 5090 4581 34.8 40.7 125 BXRC-30H4000-D-7x 3000 97 1050 3806 3426 29.0 30.5 125 BXRC-30A4001-B-738,9 3000 93 900 3884 3495 34.8 31.3 124 BXRC-30A4001-C-738,9 3000 93 1170 5049 4544 34.8 40.7 124 BXRC-30A4001-D-738,9 3000 93 1050 3776 3398 29.0 30.5 124 BXRC-35E4000-B-7x 3500 80 900 5450 4905 34.8 31.3 174 BXRC-35E4000-C-7x 3500 80 1170 7085 6376 34.8 40.7 174 BXRC-35E4000-D-7x 3500 80 1050 5298 4768 29.0 30.5 174 BXRC-35G4000-B-7x 3500 90 900 4479 4031 34.8 31.3 143 BXRC-35G4000-C-7x 3500 90 1170 5822 5240 34.8 40.7 143 BXRC-35G4000-D-7x 3500 90 1050 4354 3919 29.0 30.5 143 BXRC-35A4001-B-738,9 3500 93 900 4134 3721 34.8 31.3 132 BXRC-35A4001-C-738,9 3500 93 1170 5375 4837 34.8 40.7 132 BXRC-35A4001-D-73 3500 93 1050 4019 3617 29.0 30.5 132 BXRC-40C4001-B-74 4000 70 900 5732 5158 34.8 31.3 183 8,9 BXRC-40C4001-C-74 4000 70 1170 7451 6706 34.8 40.7 183 BXRC-40C4001-D-74 4000 70 1050 5572 5015 29.0 30.5 183 BXRC-40E4000-B-7x 4000 80 900 5481 4933 34.8 31.3 175 BXRC-40E4000-C-7x 4000 80 1170 7125 6413 34.8 40.7 175 BXRC-40E4000-D-7x 4000 80 1050 5329 4796 29.0 30.5 175 BXRC-40G4000-B-7x 4000 90 900 4573 4115 34.8 31.3 146 BXRC-40G4000-C-7x 4000 90 1170 5945 5350 34.8 40.7 146 BXRC-40G4000-D-7x 4000 90 1050 4446 4001 29.0 30.5 146 BXRC-40H4000-B-73 4000 97 900 4134 3721 34.8 31.3 132 BXRC-40H4000-C-73 4000 97 1170 5375 4837 34.8 40.7 132 BXRC-40H4000-D-73 4000 97 1050 4019 3617 29.0 30.5 132 BXRC-40A4001-B-738,9 4000 93 900 4479 4031 34.8 31.3 143 BXRC-40A4001-C-738,9 4000 93 1170 5822 5240 34.8 40.7 143 BXRC-40A4001-D-738,9 4000 93 1050 4354 3919 29.0 30.5 143 BXRC-50C4001-B-7x 5000 70 900 5763 5187 34.8 31.3 184 BXRC-50C4001-C-7x 5000 70 1170 7492 6743 34.8 40.7 184 BXRC-50C4001-D-7x 5000 70 1050 5603 5043 29.0 30.5 184 BXRC-50E4001-B-7x 5000 80 900 5544 4989 34.8 31.3 177 BXRC-50E4001-C-7x 5000 80 1170 7207 6486 34.8 40.7 177 BXRC-50E4001-D-7x 5000 80 1050 5390 4851 29.0 30.5 177 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 4 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-50G4001-B-7x 5000 90 900 4792 4313 34.8 31.3 153 BXRC-50G4001-C-7x 5000 90 1170 6230 5607 34.8 40.7 153 BXRC-50G4001-D-7x 5000 90 1050 4659 4193 29.0 30.5 153 BXRC-56G4000-B-74 5600 90 900 4823 4341 34.8 31.3 154 BXRC-56G4000-C-74 5600 90 1170 6270 5643 34.8 40.7 154 BXRC-56G400x-D-74 5600 90 1050 4689 4220 29.0 30.5 154 BXRC-56H4000-D-74 5600 97 1050 4233 3809 29.0 30.5 139 BXRC-57C4001-B-7x 5700 70 900 5606 5046 34.8 31.3 179 BXRC-57C4001-C-7x 5700 70 1170 7288 6559 34.8 40.7 179 BXRC-57C4001-D-7x 5700 70 1050 5451 4905 29.0 30.5 179 BXRC-57E4001-B-7x 5700 80 900 5324 4792 34.8 31.3 170 BXRC-57E4001-C-7x 5700 80 1170 6922 6230 34.8 40.7 170 BXRC-57E4001-D-7x 5700 80 1050 5177 4659 29.0 30.5 170 BXRC-65C4001-B-7x 6500 70 900 5606 5046 34.8 31.3 179 BXRC-65C4001-C-7x 6500 70 1170 7288 6559 34.8 40.7 179 BXRC-65C4001-D-7x 6500 70 1050 5451 4905 29.0 30.5 179 BXRC-65E4001-B-7x 6500 80 900 5387 4848 34.8 31.3 172 BXRC-65E4001-C-7x 6500 80 1170 7003 6303 34.8 40.7 172 BXRC-65E4001-D-7x 6500 80 1050 5237 4714 29.0 30.5 172 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 5 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A4001-B-73 3000 80 93 900 3612 3251 34.3 30.9 116 BXRC-30A4001-C-73 3000 80 93 1170 4695 4226 34.3 40.2 116 BXRC-30A4001-D-73 3000 80 93 1050 3511 3160 28.5 29.9 116 BXRC-35A4001-B-73 3500 80 93 900 3845 3460 34.3 30.9 123 BXRC-35A4001-C-73 3500 80 93 1170 4998 4498 34.3 40.2 123 BXRC-35A4001-D-73 3500 80 93 1050 3738 3364 28.5 29.9 123 BXRC-40A4001-B-73 4000 80 93 900 4165 3749 34.3 30.9 133 BXRC-40A4001-C-73 4000 80 93 1170 5415 4873 34.3 40.2 133 BXRC-40A4001-D-73 4000 80 93 1050 4050 3645 28.5 29.9 133 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 85 BXRC-17E4000-B-74 1750 80 900 2593 2334 33.9 30.5 BXRC-17E4000-C-74 1750 80 1170 3261 2935 33.9 39.7 82 BXRC-17E4000-D-74 1750 80 1050 2439 2195 28.1 29.5 83 BXRC-20B4001-C-73 2000 65 1170 5753 5178 33.9 39.7 145 BXRC-20B4001-D-73 2000 65 1050 4303 3872 28.1 29.5 146 BXRC-25E4000-B-74 2500 80 900 4313 3881 33.9 30.5 141 BXRC-25E4000-C-74 2500 80 1170 5607 5046 33.9 39.7 141 BXRC-25E4000-D-74 2500 80 1050 4193 3774 28.1 29.5 142 BXRC-27E4000-B-7x 2700 80 900 4510 4059 33.9 30.5 148 BXRC-27E4000-C-7x 2700 80 1170 5863 5277 33.9 39.7 148 BXRC-27E4000-D-7x 2700 80 1050 4385 3946 28.1 29.5 149 BXRC-27G40H0-B-7x 2700 90 900 3862 3476 33.9 30.5 127 BXRC-27G40H0-C-7x 2700 90 1170 5020 4518 33.9 39.7 127 BXRC-27G40H0-D-7x 2700 90 1050 3754 3379 28.1 29.5 127 BXRC-27G4000-B-7x 2700 90 900 3721 3349 33.9 30.5 122 BXRC-27G4000-C-7x 2700 90 1170 4837 4353 33.9 39.7 122 BXRC-27G4000-D-7x 2700 90 1050 3617 3256 28.1 29.5 123 BXRC-27H4000-B-7x 2700 97 900 3298 2968 33.9 30.5 108 BXRC-27H4000-C-7x 2700 97 1170 4287 3859 33.9 39.7 108 BXRC-27H4000-D-7x 2700 97 1050 3206 2886 28.1 29.5 109 164 BXRC-30C4001-B-74 3000 70 900 5017 4516 33.9 30.5 BXRC-30C4001-C-74 3000 70 1170 6523 5870 33.9 39.7 164 BXRC-30C4001-D-74 3000 70 1050 4878 4390 28.1 29.5 165 157 BXRC-30E4000-B-7x 3000 80 900 4792 4313 33.9 30.5 BXRC-30E4000-C-7x 3000 80 1170 6230 5607 33.9 39.7 157 BXRC-30E4000-D-7x 3000 80 1050 4659 4193 28.1 29.5 158 BXRC-30G40H0-B-7x 3000 90 900 3890 3501 33.9 30.5 127 BXRC-30G40H0-C-7x 3000 90 1170 5057 4551 33.9 39.7 127 BXRC-30G40H0-D-7x 3000 90 1050 3782 3404 28.1 29.5 128 133 BXRC-30G4000-B-7x 3000 90 900 4059 3653 33.9 30.5 BXRC-30G4000-C-7x 3000 90 1170 5277 4749 33.9 39.7 133 BXRC-30G4000-D-7x 3000 90 1050 3946 3552 28.1 29.5 134 BXRC-30G400C-B-73 3000 90 900 3749 3374 33.9 30.5 123 BXRC-30G400C-D-73 3000 90 1050 3645 3280 28.1 29.5 124 BXRC-30H4000-B-7x 3000 97 900 3524 3171 33.9 30.5 115 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 7 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30H4000-C-7x 3000 97 1170 4581 4122 33.9 39.7 115 BXRC-30H4000-D-7x 3000 97 1050 3426 3083 28.1 29.5 116 BXRC-30A4001-B-738,9 3000 93 900 3495 3146 33.9 30.5 115 BXRC-30A4001-C-738,9 3000 93 1170 4544 4090 33.9 39.7 115 BXRC-30A4001-D-738,9 3000 93 1050 3398 3058 28.1 29.5 115 161 BXRC-35E4000-B-7x 3500 80 900 4905 4414 33.9 30.5 BXRC-35E4000-C-7x 3500 80 1170 6376 5739 33.9 39.7 161 BXRC-35E4000-D-7x 3500 80 1050 4768 4292 28.1 29.5 162 132 BXRC-35G4000-B-7x 3500 90 900 4031 3628 33.9 30.5 BXRC-35G4000-C-7x 3500 90 1170 5240 4716 33.9 39.7 132 BXRC-35G4000-D-7x 3500 90 1050 3919 3527 28.1 29.5 133 BXRC-35A4001-B-738,9 3500 93 900 3721 3349 33.9 30.5 122 BXRC-35A4001-C-738,9 3500 93 1170 4837 4353 33.9 39.7 122 BXRC-35A4001-D-738,9 3500 93 1050 3617 3256 28.1 29.5 123 BXRC-40C4001-B-74 4000 70 900 5158 4643 33.9 30.5 169 BXRC-40C4001-C-74 4000 70 1170 6706 6035 33.9 39.7 169 BXRC-40C4001-D-74 4000 70 1050 5015 4514 28.1 29.5 170 BXRC-40E4000-B-7x 4000 80 900 4933 4440 33.9 30.5 162 BXRC-40E4000-C-7x 4000 80 1170 6413 5771 33.9 39.7 162 BXRC-40E4000-D-7x 4000 80 1050 4796 4316 28.1 29.5 163 135 BXRC-40G4000-B-7x 4000 90 900 4115 3704 33.9 30.5 BXRC-40G4000-C-7x 4000 90 1170 5350 4815 33.9 39.7 135 BXRC-40G4000-D-7x 4000 90 1050 4001 3601 28.1 29.5 136 BXRC-40H4000-B-7x 4000 97 900 3721 3349 33.9 30.5 122 BXRC-40H4000-C-7x 4000 97 1170 4837 4353 33.9 39.7 122 BXRC-40H4000-D-7x 4000 97 1050 3617 3256 28.1 29.5 123 BXRC-40A4001-B-737,8 4000 93 900 4031 3628 33.9 30.5 132 BXRC-40A4001-C-737,8 4000 93 1170 5240 4716 33.9 39.7 132 BXRC-40A4001-D-737,8 4000 93 1050 3919 3527 28.1 29.5 133 BXRC-50C4001-B-74 5000 70 900 5187 4668 33.9 30.5 170 BXRC-50C4001-C-74 5000 70 1170 6743 6068 33.9 39.7 170 BXRC-50C4001-D-74 5000 70 1050 5043 4538 28.1 29.5 171 BXRC-50E4001-B-74 5000 80 900 4989 4490 33.9 30.5 164 BXRC-50E4001-C-74 5000 80 1170 6486 5837 33.9 39.7 164 BXRC-50E4001-D-74 5000 80 1050 4851 4366 28.1 29.5 164 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 8 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-50G4001-B-7x 5000 90 900 4313 3881 33.9 30.5 141 BXRC-50G4001-C-7x 5000 90 1170 5607 5046 33.9 39.7 141 BXRC-50G4001-D-7x 5000 90 1050 4193 3774 28.1 29.5 142 142 BXRC-56G4000-B-74 5600 90 900 4341 3907 33.9 30.5 BXRC-56G4000-C-74 5600 90 1170 5643 5079 33.9 39.7 142 BXRC-56G400x-D-74 5600 90 1050 4220 3798 28.1 29.5 143 BXRC-56H4000-D-74 5600 97 1050 3809 3428 28.1 29.5 129 BXRC-57C4001-B-7x 5700 70 900 5046 4541 33.9 30.5 165 BXRC-57C4001-C-7x 5700 70 1170 6559 5903 33.9 39.7 165 BXRC-57C4001-D-7x 5700 70 1050 4905 4415 28.1 29.5 166 157 BXRC-57E4001-B-7x 5700 80 900 4792 4313 33.9 30.5 BXRC-57E4001-C-7x 5700 80 1170 6230 5607 33.9 39.7 157 BXRC-57E4001-D-7x 5700 80 1050 4659 4193 28.1 29.5 158 BXRC-65C4001-B-7x 6500 70 900 5046 4541 33.9 30.5 165 BXRC-65C4001-C-7x 6500 70 1170 6559 5903 33.9 39.7 165 BXRC-65C4001-D-7x 6500 70 1050 4905 4415 28.1 29.5 166 BXRC-65E4001-B-7x 6500 80 900 4848 4364 33.9 30.5 159 BXRC-65E4001-C-7x 6500 80 1170 6303 5673 33.9 39.7 159 BXRC-65E4001-D-7x 6500 80 1050 4714 4242 28.1 29.5 160 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 9 Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI BXRC-17E4000-B-7x 80 BXRC-17E4000-C-7x 80 BXRC-17E4000-D-7x 80 BXRC-20B4001-C-73 65 BXRC-20B4001-D-73 65 BXRC-25E4000-B-74 80 BXRC-25E4000-C-74 80 BXRC-25E4000-D-74 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 1488 1955 2881 4157 5241 1872 2458 3624 5228 6592 1402 1831 2710 4006 5161 3302 4336 6392 9222 11628 2474 3230 4781 7067 9104 2475 3250 4792 6913 8717 3218 4226 6230 8987 11332 2411 3148 4659 6887 8872 1360 1777 2593 3662 4504 1710 2235 3261 4606 5664 1281 1665 2439 3529 4434 3016 3942 5753 8124 9991 2260 2936 4303 6226 7822 2261 2955 4313 6090 7490 2940 3842 i102 7917 9736 2203 2862 4193 6067 7623 100 96 92 86 81 96 93 89 84 78 96 93 89 84 78 170 163 157 147 137 170 163 157 147 137 166 159 153 144 134 166 159 153 144 134 166 159 153 144 134 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27E4000-B-7x 80 BXRC-27E4000-C-7x 80 BXRC-27E4000-D-7x 80 BXRC-27G40H0-B-7x 90 BXRC-27G40H0-C-7x 90 BXRC-27G40H0-D-7x 90 BXRC-27G4000-B-7x 90 BXRC-27G4000-C-7x 90 BXRC-27G4000-D-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 2588 3399 5011 7230 9116 3365 4419 6515 9399 11850 2521 3292 4872 7202 9277 2216 2911 4291 6190 7805 2881 3784 5578 8048 10147 2159 2818 4172 6167 7944 2135 2804 4134 5965 7520 2776 3646 5375 7754 9776 2080 2716 4019 5942 7654 2365 3090 4510 6369 7832 3074 4017 5863 8280 10182 2303 2993 4385 6345 7971 2025 2646 3862 5453 6706 2632 3440 5020 7089 8718 1972 2562 3754 5433 6825 1951 2550 3721 5254 6462 2536 3314 4837 6831 8400 1900 2469 3617 5234 6576 173 167 160 150 140 173 167 160 150 140 173 167 160 150 140 148 143 137 129 120 148 143 137 129 120 148 143 137 129 120 143 137 132 124 116 143 137 132 124 116 143 137 132 124 116 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27H4000-B-7x 97 BXRC-27H4000-C-7x 97 BXRC-27H4000-D-7x 97 BXRC-30C4001-B-74 70 BXRC-30C4001-C-74 70 BXRC-30C4001-D-74 70 BXRC-30E4000-B-7x 80 BXRC-30E4000-C-7x 80 BXRC-30E4000-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 1893 2486 3664 5287 6666 2460 3231 4764 6873 8665 1844 2407 3563 5267 6784 2879 3782 5575 8043 10141 3743 4916 7247 10456 13183 2805 3662 5420 8013 10321 2750 3612 5324 7682 9685 3575 4695 6922 9986 12591 2679 3497 5177 7653 9857 1729 2260 3298 4657 5727 2248 2938 4287 6054 7446 1684 2188 3206 4640 5829 2631 3438 5017 7085 8713 3420 4469 6523 9211 11327 2563 3329 4878 7059 8868 2512 3283 4792 6767 8322 3266 4269 6230 8797 10818 2447 3180 4659 6741 8470 127 122 117 110 102 127 122 117 110 102 127 122 117 110 102 193 185 178 167 156 193 185 178 167 156 193 185 178 167 156 184 177 170 160 149 184 177 170 160 149 184 177 170 160 149 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30G40H0-B-7x 90 BXRC-30G40H0-C-7x 90 BXRC-30G40H0-D-7x 90 BXRC-30G4000-B-7x 90 BXRC-30G4000-C-7x 90 BXRC-30G4000-D-7x 90 BXRC-30G400C-B-73 90 BXRC-30G400C-D-73 BXRC-30H4000-B-7x 90 97 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 525 700 1050 1575 2100 450 600 900 1350 1800 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 2232 2932 4322 6236 7862 2902 3811 5619 8106 10221 2175 2839 4202 6212 8002 2329 3059 4510 6507 8204 3028 3977 5863 8459 10665 2269 2962 4385 6482 8350 2152 2826 4166 6010 7577 2096 2736 4050 5987 7712 2022 2656 3915 5648 7122 2040 2665 3890 5493 6755 2651 3465 5057 7141 8782 1987 2581 3782 5472 6875 2128 2781 4059 5732 7049 2767 3616 5277 7452 9164 2073 2693 3946 5710 7174 1966 2569 3749 5294 6511 1915 2488 3645 5274 6626 1847 2414 3524 4976 6119 149 144 138 130 121 149 144 138 130 121 149 144 138 130 121 156 150 144 135 126 156 150 144 135 126 156 150 144 135 126 144 138 133 125 116 144 138 133 125 116 135 130 125 117 109 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 13 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30H4000-C-7x 97 BXRC-30H4000-D-7x 97 BXRC-30A4001-B-73 93 BXRC-30A4001-C-73 93 BXRC-30A4001-D-73 93 BXRC-35E4000-B-7x 80 BXRC-35E4000-C-7x 80 BXRC-35E4000-D-7x 80 BXRC-35G4000-B-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.3 33.9 35.0 36.7 38.0 33.4 34.0 35.0 36.8 38.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 15.0 20.4 31.2 49.5 68.4 19.5 26.5 40.6 64.5 89.3 14.6 19.8 30.4 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 2629 3452 5090 7343 9258 1970 2572 3806 5627 7248 2006 2634 3884 5603 7065 2608 3425 5049 7284 9184 1954 2551 3776 5582 7190 2815 3697 5450 7862 9913 3659 4806 7085 10221 12887 2742 3580 5298 7833 10089 2313 3038 4479 6462 8147 2402 3139 4581 6468 7955 1800 2338 3426 4957 6228 1833 2395 3495 4936 6070 2382 3114 4544 6417 7891 1785 2319 3398 4917 6178 2572 3361 4905 6926 8518 3343 4369 6376 9004 11073 2505 3254 4768 6900 8669 2113 2762 4031 5692 7000 135 130 125 117 109 135 130 125 117 109 134 129 124 113 103 134 129 124 113 103 134 129 124 116 109 188 181 174 163 152 188 181 174 163 152 188 181 174 163 152 155 149 143 134 125 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 14 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-35G4000-C-7x 90 BXRC-35G4000-D-7x 90 BXRC-35A4001-B-73 80 BXRC-35A4001-C-73 80 BXRC-35A4001-D-73 80 BXRC-40C4001-B-74 80 BXRC-40C4001-C-74 80 BXRC-40C4001-D-74 80 BXRC-40E4000-B-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 3007 3949 5822 8400 10591 2253 2942 4354 6437 8292 2135 2804 4134 5965 7520 2776 3646 5375 7754 9776 2080 2716 4019 5942 7654 2960 3888 5732 8269 10426 3848 5054 7451 10750 13554 2884 3765 5572 8238 10611 2831 3718 5481 7908 9970 2747 3591 5240 7400 9100 2059 2675 3919 5671 7124 1951 2550 3721 5254 6462 2536 3314 4837 6831 8400 1900 2469 3617 5234 6576 2705 3535 5158 7284 8958 3516 4595 6706 9470 11646 2635 3423 5015 7257 9117 2586 3380 4933 6966 8566 155 149 143 134 125 155 149 143 134 125 143 137 132 124 116 143 137 132 124 116 143 137 132 124 116 198 191 183 172 160 198 191 183 172 160 198 191 183 172 160 189 182 175 164 153 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 15 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40E4000-C-7x 80 BXRC-40E4000-D-7x 80 BXRC-40G4000-B-7x 90 BXRC-40G4000-C-7x 90 BXRC-40G4000-D-7x 90 BXRC-40H4000-B-7x 97 BXRC-40H4000-C-7x 97 BXRC-40H4000-D-7x 97 BXRC-40A4001-B-73 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 3680 4833 7125 10280 12961 2758 3600 5329 7878 10147 2362 3102 4573 6597 8318 3070 4032 5945 8576 10813 2301 3004 4446 6572 8466 2135 2804 4134 5965 7520 2776 3646 5375 7754 9776 2080 2716 4019 5942 7654 2313 3038 4479 6462 8147 3362 4394 6413 9056 11136 2519 3273 4796 6940 8719 2158 2820 4115 5812 7147 2805 3666 5350 7555 9291 2102 2731 4001 5790 7274 1951 2550 3721 5254 6462 2536 3314 4837 6831 8400 1900 2469 3617 5234 6576 2113 2762 4031 5692 7000 189 182 175 164 153 189 182 175 164 153 158 152 146 137 128 158 152 146 137 128 158 152 146 137 128 143 137 132 124 116 143 137 132 124 116 143 137 132 124 116 155 149 143 134 125 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 16 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40A4001-C-73 80 BXRC-40A4001-D-73 80 BXRC-50C4001-B-74 70 BXRC-50C4001-C-74 70 BXRC-50C4001-D-74 70 BXRC-50E4001-B-74 80 BXRC-50E4001-C-7x 80 BXRC-50E4001-D-7x 80 BXRC-50G4001-B-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 3007 3949 5822 8400 10591 2253 2942 4354 6437 8292 2977 3909 5763 8314 10483 3869 5082 7492 10808 13628 2899 3785 5603 8283 10669 2863 3760 5544 7998 10084 3722 4888 7207 10397 13109 2789 3641 5390 7968 10263 2475 3250 4792 6913 8717 2747 3591 5240 7400 9100 2059 2675 3919 5671 7124 2719 3554 5187 7324 9007 3535 4620 6743 9521 11709 2649 3441 5043 7297 9167 2616 3419 4989 7046 8664 3401 4444 6486 9159 11264 2548 3311 4851 7019 8818 2261 2955 4313 6090 7490 155 149 143 134 125 155 149 143 134 125 199 192 184 173 161 199 192 184 173 161 199 192 184 173 161 192 184 177 166 155 192 184 177 166 155 192 184 177 166 155 166 159 153 144 134 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 17 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-50G4001-C-7x 90 BXRC-50G4001-D-7x 90 BXRC-56G4000-B-74 90 BXRC-56G4000-C-74 90 BXRC-56G400x-D-74 90 BXRC-56H4000-D-74 97 BXRC-57C4001-B-7x 70 BXRC-57C4001-C-7x 70 BXRC-57C4001-D-7x 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 3218 4226 6230 8987 11332 2411 3148 4659 6887 8872 2491 3272 4823 6959 8774 3239 4253 6270 9046 11406 2427 3168 4689 6932 8930 2190 2860 4233 6257 8060 2896 3803 5606 8088 10198 3764 4944 7288 10515 13257 2821 3682 5451 8058 10379 2940 3842 5607 7917 9736 2203 2862 4193 6067 7623 2276 2974 4341 6130 7539 2959 3867 5643 7969 9800 2217 2880 4220 6107 7672 2001 2600 3809 5512 6925 2646 3457 5046 7125 8762 3439 4495 6559 9263 11391 2577 3348 4905 7098 8918 166 159 153 144 134 166 159 153 144 134 167 160 154 145 135 167 160 154 145 135 167 160 154 145 135 150 145 139 131 122 194 186 179 168 157 194 186 179 168 157 194 186 179 168 157 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 18 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-57E4001-B-7x 80 BXRC-57E4001-C-7x 80 BXRC-57E4001-D-7x 80 BXRC-65C4001-B-7x 70 BXRC-65C4001-C-7x 70 BXRC-65C4001-D-7x 70 BXRC-65E4001-B-7x 80 BXRC-65E4001-C-7x 80 BXRC-65E4001-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 450 600 900 1350 1800 585 780 1170 1755 2340 525 700 1050 1575 2100 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 27.7 28.2 29.0 30.4 31.5 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 14.9 20.4 31.3 48.1 65.1 19.4 26.5 40.7 62.5 84.6 14.6 19.8 30.5 47.9 66.2 2750 3612 5324 7682 9685 3575 4695 6922 9986 12591 2679 3497 5177 7653 9857 2896 3803 5606 8088 10198 3764 4944 7288 10515 13257 2821 3682 5451 8058 10379 2782 3654 5387 7772 9799 3617 4750 7003 10104 12739 2710 3538 5237 7743 9973 2512 3283 4792 6767 8322 3266 4269 6230 8797 10818 2447 3180 4659 6741 8470 2646 3457 5046 7125 8762 3439 4495 6559 9263 11391 2577 3348 4905 7098 8918 2542 3322 4848 6847 8420 3305 4319 6303 8901 10946 2476 3217 4714 6821 8569 184 177 170 160 149 184 177 170 160 149 184 177 170 160 149 194 186 179 168 157 194 186 179 168 157 194 186 179 168 157 186 179 172 162 151 186 179 172 162 151 186 179 172 162 151 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 19 Electrical Characteristics Table 5: Electrical Characteristics Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Part Number BXRC-xxx400x-B-7x BXRC-xxx400x-C-7x BXRC-xxx400x-D-7x Drive Current (mA) Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) 0.15 31.0 38.4 -14.9 0.19 32.2 39.8 37.4 -14.9 0.11 31.0 38.4 36.1 38.8 -14.9 0.13 32.2 39.8 26.8 29.0 31.2 -12.2 0.16 25.8 32.0 29.2 31.5 33.9 -12.2 0.19 28.2 34.7 Minimum Typical Maximum 900 32.2 34.8 37.4 -14.9 1800 33.4 36.1 38.8 1170 32.2 34.8 2340 33.4 1050 2100 Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. 20 Eye Safety Table 6: Eye Safety Risk Group (RG) Classifications Part Number BXRC-xxx400x-B-7x BXRC-xxx400x-C-7x BXRC-xxx400x-D-7x CCT1,5 Drive Current 5 (mA) 2700K/3000K 4000K2 5000K3 6500K4 900 RG1 RG1 RG1 RG1 1350 RG1 RG1 RG1 RG2 1800 RG1 RG1 RG2 RG2 1170 RG1 RG1 RG1 RG1 1755 RG1 RG1 RG2 RG2 2340 RG1 RG1 RG2 RG2 1050 RG1 RG1 RG1 RG1 1575 RG1 RG1 RG1 RG2 2100 RG1 RG1 RG2 RG2 Notes for Table 6: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. 21 Absolute Maximum Ratings Table 7: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx400x-B-7x BXRC-xxx400x-C-7x BXRC-xxx400x-D-7x Maximum Drive Current3 1800mA 2340mA 2100mA Maximum Peak Pulsed Drive Current4 2570mA 3340mA 3000mA Maximum Reverse Voltage5 -60V -60V -50V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 22 Performance Curves Figure 2: Vero 18C Drive Current vs. Voltage 2000 2700 1800 2400 1600 2100 1400 Forward Current (mA) Forward Current (mA) Figure 1: Vero 18B Drive Current vs. Voltage 1200 1000 800 600 1800 1500 1200 900 600 400 300 200 0 32 33 34 35 36 37 38 0 39 32 33 34 200% 2000 180% 1750 160% 1500 140% Relative Luminous Flux Forward Current (mA) 2250 1250 1000 750 500 38 39 100% 80% 60% 40% 20% 26 27 28 29 30 31 0% 32 0 200 400 600 Forward Voltage (V) 800 1000 1200 1400 1600 1800 2000 Forward Current (mA) Figure 5: Vero 18C Typical Relative Flux vs. Current Figure 6 Vero 18D Typical Relative Flux vs. Current y = -7E-08x + 0.001x + 0.027 2 200% 200% 180% 180% 160% 160% 140% 140% Relative Luminous Flux Relative Luminous Flux 37 120% 250 120% 100% 80% 60% 40% 120% 100% 80% 60% 40% 20% 0% 36 Figure 4: Vero 18B Typical Relative Flux vs. Current Figure 3: Vero 18D Drive Current vs. Voltage 0 35 Forward Voltage (V) Forward Voltage (V) 20% 100 400 700 1000 1300 1600 Forward Current (mA) 1900 2200 2500 0% 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Forward Current (mA) Notes for Figures 1-6: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 23 Performance Curves Figure 8: Typical DC ccy Shift vs. Case Temperature Figure 7: Typical DC Flux vs. Case Temperature 103% Neutral White 100% 25°C Pulsed 25 50 75 100 125 -0.003 94% 91% -0.006 -0.009 88% Warm White -0.012 85% 82% 0 0.000 Cool White 97% ccy Shift Relative Luminous Flux 0.003 Warm White -0.015 0 25 50 75 100 125 Neutral White Cool White 25°C Pulsed Case Temperature (°C) Case Temperature (°C) Figure 9: Typical DC ccx Shift vs. Case Temperature 0.000 0 25 50 75 100 125 -0.002 ccx Shift -0.004 -0.006 -0.008 Warm White -0.010 -0.012 Neutral White Cool White 25°C Pulsed Case Temperature (°C) Notes for Figures 7-9: 1. Characteristics shown for warm white based on 3000K and 80 CRI. 2. Characteristics shown for neutral white based on 4000K and 80 CRI. 3. Characteristics shown for cool white based on 5000K and 70 CRI. 4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information. 24 Performance Curves Figure 11: 2000K, 65 CRI Color Shift vs. Case Temperature Figure 10: 1750K Color Shift vs. Case Temperature1 0.3705 0.37 0.4101 Pulsed Center Point Tc = 25°C 15°C 0.41 0.4099 25°C 0.4098 Pulsed Center Point Tc=25°C 15°C 25°C 0.4097 0.3695 0.369 ccy ccy 45°C 45°C 0.4096 0.4095 65°C 0.4094 70°C 0.4093 85°C 85°C 0.4092 0.3685 105°C 0.368 0.5196 105°C 0.4091 0.5198 0.52 0.5202 0.5204 0.409 0.525 0.5206 0.526 0.527 0.528 Figure 12: 2500K Color Shift vs. Case Temperature1 25°C 0.4135 0.413 Pulsed Center Point Tc = 25°C 0.532 0.4125 0.399 85°C 0.397 105°C 0.396 0.47 65°C 0.398 85°C 0.4105 0.468 45°C 0.4 70°C 0.4115 Pulsed Center Point Tc=25°C 25°C 0.401 45°C 0.412 15°C 0.402 ccy ccy 0.531 0.403 15°C 0.414 0.472 0.474 0.476 0.395 0.444 0.478 105°C 0.4445 0.445 0.4455 Figure 14: 2700K, 97 CRI Color Shift vs. Case Temperature1 0.446 0.4465 0.447 ccx ccx Figure 15: 3000K, 97 CRI Color Shift vs. Case Temperature1 0.4110 0.4050 15°C Pulsed Center Point Tc = 25°C 0.4100 25°C 0.4080 Pulsed Center Point Tc = 25°C 15°C 0.4030 25°C 0.4090 45°C 0.4010 45°C ccy ccy 0.53 Figure 13: 3000K, 90 CRI Color Shift vs. Case Temperature1,3 0.4145 0.411 0.529 ccx ccx 0.4070 65°C 70°C 0.3990 0.4060 85°C 85°C 0.4050 0.3970 105°C 0.4040 105°C 0.4030 0.457 0.4572 0.4574 0.4576 0.4578 0.458 ccx Note for Figures 10-15: 1. Measurements made under DC test conditions at the nominal drive current. 2. Typical color shift is shown with a tolerance of ±0.002. 3. Characteristics shown for Decor Series Showcase products, BXRC-30G400C-x-73 0.3950 0.4323 0.4328 0.4333 0.4338 0.4343 0.4348 0.4353 ccx 25 Performance Curves Figure 16: 5600K Color Shift vs. Case Temperature1,3 Figure 17: 3000K Class A Color Shift vs. Case Temperature1 0.344 0.369 15°C 0.342 0.34 25°C 0.338 0.367 0.332 70°C 0.33 0.365 0.364 70°C 0.363 85°C 0.328 Pulsed Center Point Tc=25°C 45°C 45°C 0.334 ccy ccy 25°C 0.366 0.336 0.326 0.368 Pulsed Center Point Tc = 25°C 15°C 85°C 0.362 105°C 0.361 0.324 0.322 0.32 0.322 0.324 0.326 0.328 105°C 0.36 0.416 0.33 0.4165 0.417 ccx Figure 18: 3500K Class A Color Shift vs. Case Temperature1 ccx 0.4175 0.418 0.4185 Figure 19: 4000K Class A Color Shift vs. Case Temperature1 0.37 0.3760 15°C 0.368 Pulsed Center Point Tc=25°C 25°C 0.366 15°C 0.3740 25°C 0.3720 45°C 45°C ccy 0.3700 ccy Pulsed Center Point Tc=25°C 0.364 0.3680 70°C 0.362 85°C 0.3660 0.36 85°C 0.3640 105°C 0.358 0.392 70°C 105°C 0.393 0.394 0.395 0.396 0.397 ccx 0.3620 0.373 0.374 0.375 0.376 ccx 0.377 0.378 0.379 Note for Figures 16-19: 1. Measurements made under DC test conditions at the nominal drive current. 2. Typical color shift is shown with a tolerance of ±0.002. 3. Color shift shown for product hot targeted at Tc=85°C 26 Typical Radiation Pattern Figure 20: Typical Spatial Radiation Pattern Note for Figure 20: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value. Figure 21: Typical Polar Radiation Pattern 27 Typical Color Spectrum Figure 22: Typical Color Spectrum 110% 3000K 100% 4000K 5000K Relative Spectral Power Distribution 90% 6500K 80% 70% 60% 50% 40% 30% 20% 10% 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 22: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. Figure 23: Typical Color Spectrum for Vero 18 with Décor Series 1 17E 20B 0.9 25E 27H 30G (Décor Series Showcase) 0.8 30H Relative Spectral Power Distribution 56G 56H 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 400 450 500 550 600 Wavelength (nm) 650 700 750 800 Note for Figure 23: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 28 Mechanical Dimensions Figure 24: Drawing for Vero 18 LED Array Notes for Figure 24: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Mounting holes (2X) are for M2.5 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 29 Color Binning Information Figure 25: Warm and Neutral White Test Bins in xy Color Space 0.44 2500K 4SDCM 3 SDCM 4 SDCM 2000K 3SDCM 2700K 0.42 3000K 3500K 0.4 Y 4000K 1750K 4SDCM 0.38 0.36 0.34 0.36 0.39 0.42 0.45 X 0.48 0.51 0.54 Note: Pulsed Test Conditions, Tc = 25°C Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 1750K 2000K 2500K 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) - - - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - - - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - - - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.5167, 0.366) (0.5280, 0.4100) (0.4765, 0.4137) (0.4578, 0.4101) (0.4338, 0.403) (0.4465, 0.4024)2 (0.4073, 0.3917) (0.3818, 0.3797) Note for Table 8: 1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. Figure 26: Cool White Test Bins in xy Color Space 0.39 4 SDCM 3 SDCM 0.38 0.37 5000K 0.36 5700K Y 0.35 0.34 6500K 0.33 0.32 0.31 0.3 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Bin Code 5000K 5600K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5310K - 6020K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5475K - 5830K) (5481K - 5829K) (6270K - 6765K) 73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (5490K - 5820K) (6250K - 6745K) Center Point (x,y) (0.3447, 0.3553) (0.3293, 0.3423) (0.3287, 0.3417) (0.3123, 0.3282) Note for Table 9: 1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C. 30 Packaging and Labeling Figure 27: Drawing for Vero 18 Packaging Tray Notes for Figure 27: 1. Dimensions are in millimeters. 2. Drawings are not to scale. 31 Packaging and Labeling Figure 28: Vero Series Packaging and Labeling Notes for Figure 28: 1. Each tray holds 100 COBs. 2. Each tray is vacuum sealed in an anti-static bag and placed in its own box. 3. Each tray, bag and box is to be labeled as shown above. Figure 29: Gen. 7 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E4000C 73 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 32 Design Resources Application Notes 3D CAD Models Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. Optical Source Models LM80 Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. Precautions CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN31 for additional information. CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. Disclaimers MINOR PRODUCT CHANGE POLICY STANDARD TEST CONDITIONS The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Unless otherwise stated, array testing is performed at the nominal drive current. 33 About Bridgelux: Bridging Light and Life™ At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com © 2016-2019 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 7 Vero 18 Array Series Product Data Sheet DS92 Rev. Q (09/2020) 34
BXRC-30G4000-C-72 价格&库存

很抱歉,暂时无法提供与“BXRC-30G4000-C-72”相匹配的价格&库存,您可以联系我们找货

免费人工找货