0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BXRC-50E10K1-B-74

BXRC-50E10K1-B-74

  • 厂商:

    BRIDGELUX

  • 封装:

    -

  • 描述:

    LEDCOBVERO295000KROUND

  • 数据手册
  • 价格&库存
BXRC-50E10K1-B-74 数据手册
Bridgelux Gen 7 Vero 29 Array ® ® Product Data Sheet DS93 1 Vero® Series Introduction Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and typical R9 value of 98, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen lamps Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series Food products are a must have for any butcher counter or bakery. Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these industries. Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Features • Efficacy of 170 lm/W typical • Lumen output performance ranges from 3,850 to 38,400 lumens • Broad range of CCT options from 1750K to 6500K • CRI options include minimum 65, 70, 80, and 90, 2 and 3 SDCM color control for 2700K-4000K CCT Benefits • Broad application coverage for interior and exterior lighting • Flexibility for application driven lighting design requirements • High quality true color reproduction • Uniform consistent white light • Reliable operation at up to 2X nominal drive current • Flexibility in design optimization • Radial die pattern and improved lumen density • Enhanced ease of use and assembly • Thermally isolated solder pads • Solderless connectivity enables plug & play installation and field upgradability • Onboard connector port • Top side part number markings • Vf bin code backside marking • Improved inventory management and quality control Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 10 Electrical Characteristics 20 Eye Safety 21 Absolute Maximum Ratings 22 Performance Curves 23 Typical Radiation Pattern 27 Typical Color Spectrum 28 Mechanical Dimensions 29 Color Binning Information 30 Packaging and Labeling 31 Design Resources 33 Precautions 33 Disclaimers 33 About Bridgelux 34 1 Product Feature Map Vero 29 is the largest form factor in the Vero family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. Mounting holes Thermally isolated solder pads reduce manufacturing cycle time and complexity Polarity indication marks simplify manufacturing operator instructions Tc Measurement point 2D Bar code provides full manufacturing traceability Top side part number marking improves inventory management and outgoing quality control Radial die configuration improves lumen density and beam control Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Optional Molex Pico-EZmate™ connector harness (sold separately) Product Nomenclature The part number designation for Bridgelux Vero LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 BXRC – 30 E 10K 0 – C – 7 3 CCT Bin Options Product Family Nominal CCT 17 = 1,750K 20 = 2,000K 25 = 2,500K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 56 = 5,600K 57 = 5,700K 65 = 6,500K Gen. 7 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Array Configuration CRI B = 65 CRI min. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted Flux Indicator 10Kx = 10,000 lm 2 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) BXRC-17E10K0-B-74 1750 80 1800 8611 7750 BXRC-17E10K0-C-74 1750 80 1710 10918 9826 Typical Power (W) Typical Efficacy (lm/W) 52.0 93.6 92 69.4 118.7 92 Typical Vf (V) BXRC-17E10K0-D-74 1750 80 2100 7264 6538 37.6 79.0 92 BXRC-20B10K1-C-73 2000 65 1710 18632 16769 69.4 118.7 157 BXRC-20B10K1-D-73 2000 65 2100 12397 11157 37.6 79.0 157 BXRC-25E10K0-B-74 2500 80 1800 14321 12889 52.0 93.6 153 BXRC-25E10K0-C-74 2500 80 1710 18157 16341 69.4 118.7 153 BXRC-25E10K0-D-74 2500 80 2100 12081 10873 37.6 79.0 153 BXRC-27E10K0-B-7x 2700 80 1800 14976 13478 52.0 93.6 160 BXRC-27E10K0-C-7x 2700 80 1710 18988 17089 69.4 118.7 160 BXRC-27E10K0-D-7x 2700 80 2100 12634 11370 37.6 79.0 160 BXRC-27G1KH0-B-7x 2700 90 1800 12823 11541 52.0 93.6 137 BXRC-27G1KH0-C-7x 2700 90 1710 16258 14633 69.4 118.7 137 BXRC-27G1KH0-D-7x 2700 90 2100 10818 9736 37.6 79.0 137 BXRC-27G10K0-B-7x 2700 90 1800 12355 11120 52.0 93.6 132 BXRC-27G10K0-C-7x 2700 90 1710 15665 14098 69.4 118.7 132 BXRC-27G10K0-D-7x 2700 90 2100 10423 9380 37.6 79.0 132 BXRC-27H10K0-D-7x 2700 97 2100 9243 8319 37.6 79.0 117 BXRC-30C10K1-B-74 3000 70 1800 16661 14995 52.0 93.6 178 BXRC-30C10K1-C-74 3000 70 1710 21124 19012 69.4 118.7 178 BXRC-30C10K1-D-74 3000 70 2100 14055 12649 37.6 79.0 178 BXRC-30E10K0-B-7x10 3000 80 1800 15912 14321 52.0 93.6 170 BXRC-30E10K0-C-7x10 3000 80 1710 20175 18157 69.4 118.7 170 BXRC-30E10K0-D-7x10 3000 80 2100 13423 12081 37.6 79.0 170 BXRC-30G1KH0-B-7x 3000 90 1800 13478 12131 52.0 93.6 144 BXRC-30G1KH0-C-7x 3000 90 1710 17089 15380 69.4 118.7 144 BXRC-30G1KH0-D-7x 3000 90 2100 11370 10233 37.6 79.0 144 BXRC-30G10K0-B-7x 3000 90 1800 12917 11625 52.0 93.6 138 BXRC-30G10K0-C-7x 3000 90 1710 16377 14739 69.4 118.7 138 BXRC-30G10K0-D-7x 3000 90 2100 10896 9807 37.6 79.0 138 BXRC-30H10K0-D-7x 3000 97 2100 9870 8883 37.6 79.0 125 BXRC-30A10K1-B-738,9 3000 93 1800 11606 10446 52.0 93.6 124 BXRC-30A10K1-C-73 8,9 3000 93 1710 14716 13244 69.4 118.7 124 BXRC-30A10K1-D-738,9 3000 93 2100 9791 8812 37.6 79.0 124 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions. 3 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E10K0-B-7x10 3500 80 1800 16286 14658 52.0 93.6 174 BXRC-35E10K0-C-7x10 3500 80 1710 20649 18584 69.4 118.7 174 BXRC-35E10K0-D-7x10 3500 80 2100 13739 12365 37.6 79.0 174 BXRC-35G10K0-B-7x 3500 90 1800 13385 12046 52.0 93.6 143 BXRC-35G10K0-C-7x 3500 90 1710 16970 15273 69.4 118.7 143 BXRC-35G10K0-D-7x 3500 90 2100 11291 10162 37.6 79.0 143 BXRC-35A10K1-B-738,9 3500 93 1800 12355 11120 52.0 93.6 132 BXRC-35A10K1-C-738,9 3500 93 1710 15665 14098 69.4 118.7 132 BXRC-35A10K1-D-738,9 3500 93 2100 10423 9380 37.6 79.0 132 BXRC-40C10K1-B-74 4000 70 1800 17129 15416 52.0 93.6 183 BXRC-40C10K1-C-74 4000 70 1710 21717 19546 69.4 118.7 183 BXRC-40C10K1-D-74 4000 70 2100 14450 13005 37.6 79.0 183 BXRC-40E10K0-B-7x10 4000 80 1800 16380 14742 52.0 93.6 175 BXRC-40E10K0-C-7x10 4000 80 1710 20768 18691 69.4 118.7 175 BXRC-40E10K0-D-7x10 4000 80 2100 13818 12436 37.6 79.0 175 BXRC-40G10K0-B-7x 4000 90 1800 13666 12299 52.0 93.6 146 BXRC-40G10K0-C-7x 4000 90 1710 17326 15594 69.4 118.7 146 BXRC-40G10K0-D-7x 4000 90 2100 11528 10375 37.6 79.0 146 BXRC-40H10K0-D-7x 4000 97 2100 10423 9380 37.6 79.0 132 BXRC-40A10K1-B-738,9 4000 93 1800 13385 12046 52.0 93.6 143 143 BXRC-40A10K1-C-738,9 4000 93 1710 16970 15273 69.4 118.7 BXRC-40A10K1-D-738,9 4000 93 2100 11291 10162 37.6 79.0 143 BXRC-50C10K1-B-7x10 5000 70 1800 17222 15500 52.0 93.6 184 BXRC-50C10K1-C-7x10 5000 70 1710 21836 19652 69.4 118.7 184 BXRC-50C10K1-D-7x10 5000 70 2100 14529 13076 37.6 79.0 184 BXRC-50E10K1-B-7x 5000 80 1800 16567 14910 52.0 93.6 177 BXRC-50E10K1-C-7x 5000 80 1710 21005 18905 69.4 118.7 177 BXRC-50E10K1-D-7x 5000 80 2100 13976 12578 37.6 79.0 177 BXRC-50G10K1-B-7x 5000 90 1800 14321 12889 52.0 93.6 153 BXRC-50G10K1-C-7x 5000 90 1710 18157 16341 69.4 118.7 153 BXRC-50G10K1-D-7x 5000 90 2100 12081 10873 37.6 79.0 153 BXRC-56G10K0-B-74 5600 90 1800 14414 12973 52.0 93.6 154 154 BXRC-56G10K0-C-74 5600 90 1710 18276 16448 69.4 118.7 BXRC-56G10K0-D-74 5600 90 2100 12160 10944 37.6 79.0 154 BXRC-56H10K1-D-74 5600 97 2100 10975 9878 37.6 79.0 139 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions. 4 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C10K1-B-7x10 5700 70 1800 16754 15079 52.0 93.6 179 BXRC-57C10K1-C-7x10 5700 70 1710 21243 19118 69.4 118.7 179 BXRC-57C10K1-D-7x10 5700 70 2100 14134 12720 37.6 79.0 179 BXRC-57E10K1-B-7x10 5700 80 1800 15912 14321 52.0 93.6 170 BXRC-57E10K1-C-7x10 5700 80 1710 20175 18157 69.4 118.7 170 BXRC-57E10K1-D-7x10 5700 80 2100 13423 12081 37.6 79.0 170 BXRC-65C10K1-B-7x10 6500 70 1800 16754 15079 52.0 93.6 179 BXRC-65C10K1-C-7x10 6500 70 1710 21243 19118 69.4 118.7 179 BXRC-65C10K1-D-7x10 6500 70 2100 14134 12720 37.6 79.0 179 BXRC-65E10K1-B-7x10 6500 80 1800 16099 14489 52.0 93.6 172 BXRC-65E10K1-C-7x10 6500 80 1710 20412 18371 69.4 118.7 172 BXRC-65E10K1-D-7x10 6500 80 2100 13581 12223 37.6 79.0 172 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions. 5 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A10K1-B-73 3000 80 93 1800 10794 9715 50.9 91.6 118 118 BXRC-30A10K1-C-73 3000 80 93 1710 13685 12317 67.9 116.1 BXRC-30A10K1-D-73 3000 80 93 2100 9106 8195 36.8 77.3 118 BXRC-35A10K1-B-73 3500 80 93 1800 11490 10341 50.9 91.6 125 126 BXRC-35A10K1-C-73 3500 80 93 1710 14568 13112 67.9 116.1 BXRC-35A10K1-D-73 3500 80 93 2100 9693 8724 36.8 77.3 125 BXRC-40A10K1-B-73 4000 80 93 1800 12448 11203 50.9 91.6 136 BXRC-40A10K1-C-73 4000 80 93 1710 15782 14204 67.9 116.1 136 BXRC-40A10K1-D-73 4000 80 93 2100 10501 9451 36.8 77.3 136 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 85 BXRC-17E10K0-B-74 1750 80 1800 7750 6975 50.7 91.2 BXRC-17E10K0-C-74 1750 80 1710 9826 8844 68.1 116.4 84 BXRC-17E10K0-D-74 1750 80 2100 6538 5884 36.6 76.8 85 BXRC-20B10K0-C-73 2000 65 1710 16769 15092 68.1 116.4 144 BXRC-20B10K0-D-73 2000 65 2100 11157 10041 36.6 76.8 145 BXRC-25E10K0-B-74 2500 80 1800 12889 11600 50.7 91.2 141 BXRC-25E10K0-C-74 2500 80 1710 16341 14707 68.1 116.4 140 BXRC-25E10K0-D-74 2500 80 2100 10873 9786 36.6 76.8 142 BXRC-27E10K0-B-7x 2700 80 1800 13478 12131 50.7 91.2 148 BXRC-27E10K0-C-7x 2700 80 1710 17089 15380 68.1 116.4 147 BXRC-27E10K0-D-7x 2700 80 2100 11370 10233 36.6 76.8 148 BXRC-27G1KH0-B-7x 2700 90 1800 11541 10387 51.0 91.7 126 BXRC-27G1KH0-C-7x 2700 90 1710 14633 13169 68.4 116.9 125 BXRC-27G1KH0-D-7x 2700 90 2100 9736 8762 36.6 76.8 127 121 BXRC-27G10K0-B-7x 2700 90 1800 11120 10008 51.0 91.7 BXRC-27G10K0-C-7x 2700 90 1710 14098 12689 68.4 116.9 121 BXRC-27G10K0-D-7x 2700 90 2100 9380 8442 36.6 76.8 122 BXRC-27H10K0-D-7x 2700 97 2100 8319 7487 36.6 76.8 108 BXRC-30C10K1-B-74 3000 70 1800 14995 13495 51.0 91.7 163 BXRC-30C10K1-C-74 3000 70 1710 19012 17110 68.4 116.9 163 BXRC-30C10K1-D-74 3000 70 2100 12649 11384 36.6 76.8 165 BXRC-30E10K0-B-7x 3000 80 1800 14321 12889 51.0 91.7 156 BXRC-30E10K0-C-7x 3000 80 1710 18157 16341 68.4 116.9 155 BXRC-30E10K0-D-7x 3000 80 2100 12081 10873 36.6 76.8 157 BXRC-30G1KH0-B-7x 3000 90 1800 12131 10918 51.0 91.7 132 BXRC-30G1KH0-C-7x 3000 90 1710 15380 13842 68.4 116.9 132 BXRC-30G1KH0-D-7x 3000 90 2100 10233 9210 36.6 76.8 133 127 BXRC-30G10K0-B-7x 3000 90 1800 11625 10463 50.7 91.2 BXRC-30G10K0-C-7x 3000 90 1710 14739 13265 68.1 116.4 127 BXRC-30G10K0-D-7x 3000 90 2100 9807 8826 36.6 76.8 128 BXRC-30H10K0-D-7X 3000 97 2100 8883 7995 36.6 76.9 116 BXRC-30A10K1-B-737,8 3000 93 1800 10446 9401 50.7 91.2 115 BXRC-30A10K1-C-737,8 3000 93 1710 13244 11920 68.1 116.4 114 BXRC-30A10K1-D-737,8 3000 93 2100 8812 7931 36.6 76.8 115 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 7 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E10K0-B-7X 3500 80 1800 14658 13192 50.7 91.2 161 BXRC-35E10K0-C-7X 3500 80 1710 18584 16726 68.1 116.4 160 BXRC-35E10K0-D-7X 3500 80 2100 12365 11129 36.6 76.8 161 BXRC-35G10K0-B-7X 3500 90 1800 12046 10842 50.7 91.2 132 BXRC-35G10K0-C-7X 3500 90 1710 15273 13746 68.1 116.4 131 BXRC-35G10K0-D-7X 3500 90 2100 10162 9146 36.6 76.8 132 BXRC-35A10K1-B-737,8 3500 93 1800 11120 10008 50.7 91.2 122 BXRC-35A10K1-C-737,8 3500 93 1710 14098 12689 68.1 116.4 121 BXRC-35A10K1-D-73 3500 93 2100 9380 8442 36.6 76.8 122 BXRC-40C10K1-B-74 4000 70 1800 15416 13874 51.0 91.7 168 7,8 BXRC-40C10K1-C-74 4000 70 1710 19546 17591 68.4 116.9 167 BXRC-40C10K1-D-74 4000 70 2100 13005 11704 36.6 76.8 169 162 BXRC-40E10K0-B-7X 4000 80 1800 14742 13268 50.7 91.2 BXRC-40E10K0-C-7X 4000 80 1710 18691 16822 68.1 116.4 161 BXRC-40E10K0-D-7X 4000 80 2100 12436 11193 36.6 76.8 162 135 BXRC-40G10K0-B-7X 4000 90 1800 12299 11069 50.7 91.2 BXRC-40G10K0-C-7X 4000 90 1710 15594 14034 68.1 116.4 134 BXRC-40G10K0-D-7X 4000 90 2100 10375 9338 36.6 76.8 135 BXRC-40H10K0-D-7x 4000 97 2100 9380 8442 36.6 76.9 122 BXRC-40A10K1-B-737,8 4000 93 1800 12046 10842 50.7 91.2 132 BXRC-40A10K1-C-737,8 4000 93 1710 15273 13746 68.1 116.4 131 BXRC-40A10K1-D-737,8 4000 93 2100 10162 9146 36.6 76.8 132 BXRC-50C10K1-B-7x 5000 70 1800 15500 13950 50.7 91.2 170 BXRC-50C10K1-C-7x 5000 70 1710 19652 17687 68.1 116.4 169 BXRC-50C10K1-D-7x 5000 70 2100 13076 11768 36.6 76.8 170 BXRC-50E10K1-B-7x 5000 80 1800 14910 13419 50.7 91.2 163 BXRC-50E10K1-C-7x 5000 80 1710 18905 17014 68.1 116.4 162 BXRC-50E10K1-D-7x 5000 80 2100 12578 11320 36.6 76.8 164 BXRC-50G10K1-B-7x 5000 90 1800 12889 11600 50.7 91.2 141 BXRC-50G10K1-C-7x 5000 90 1710 16341 14707 68.1 116.4 140 BXRC-50G10K1-D-7x 5000 90 2100 10873 9786 36.6 76.8 142 BXRC-56G10K0-B-74 5600 90 1800 12973 11676 50.7 91.2 142 BXRC-56G10K0-C-74 5600 90 1710 16448 14803 68.1 116.4 141 BXRC-56G10K0-D-74 5600 90 2100 10944 9849 36.6 76.8 143 BXRC-56H10K1-D-74 5600 97 2100 9878 8890 36.6 76.9 129 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 8 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 165 BXRC-57C10K1-B-7x 5700 70 1800 15079 13571 50.7 91.2 BXRC-57C10K1-C-7x 5700 70 1710 19118 17207 68.1 116.4 164 BXRC-57C10K1-D-7x 5700 70 2100 12720 11448 36.6 76.8 166 BXRC-57E10K1-B-7x 5700 80 1800 14321 12889 50.7 91.2 157 BXRC-57E10K1-C-7x 5700 80 1710 18157 16341 68.1 116.4 156 BXRC-57E10K1-D-7x 5700 80 2100 12081 10873 36.6 76.8 157 165 BXRC-65C10K1-B-7x 6500 70 1800 15079 13571 50.7 91.2 BXRC-65C10K1-C-7x 6500 70 1710 19118 17207 68.1 116.4 164 BXRC-65C10K1-D-7x 6500 70 2100 12720 11448 36.6 76.8 166 BXRC-65E10K1-B-7x 6500 80 1800 14489 13040 50.7 91.2 159 BXRC-65E10K1-C-7x 6500 80 1710 18371 16534 68.1 116.4 158 BXRC-65E10K1-D-7x 6500 80 2100 12223 11001 36.6 76.8 159 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 9 Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI BXRC-17E10K0-B-74 80 BXRC-17E10K0-C-74 80 BXRC-17E10K0-D-74 80 BXRC-20B10K0-C-73 65 BXRC-20B10K0-D-73 65 BXRC-25E10K0-B-74 80 BXRC-25E10K0-C-74 80 BXRC-25E10K0-D-74 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.7 78.9 124.4 173.0 56.6 76.7 118.7 185.0 254.6 37.2 50.7 78.9 124.4 173.0 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.7 78.9 124.4 173.0 4470 5886 8611 12413 15887 6202 7883 10918 15489 19413 3996 5142 7264 10342 13034 10584 13452 18632 26432 33129 6819 8776 12397 17649 22243 7434 9789 14321 20643 26421 10315 13110 18157 25758 32285 6645 8552 12081 17199 21677 4081 5350 7750 11070 13998 5902 7272 9826 13321 16313 3893 4786 6538 8714 10644 10072 12409 16769 22733 27838 6644 8167 11157 14870 18164 6786 8898 12889 18410 23279 9815 12093 16341 22154 27129 6475 7959 10873 14492 17701 100 97 92 85 79 110 103 92 84 76 107 101 92 83 75 187 175 157 143 130 183 173 157 142 129 166 162 153 141 131 182 171 153 139 127 179 169 153 138 125 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27E10K0-B-7x 80 BXRC-27E10K0-C-7x 80 BXRC-27E10K0-D-7x 80 BXRC-27G1KH0-B-7x 90 BXRC-27G1KH0-C-7x 90 BXRC-27G1KH0-D-7x 90 BXRC-27G10K0-B-7x 90 BXRC-27G10K0-C-7x 90 BXRC-27G10K0-D-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 7774 10237 14976 21588 27630 10786 13709 18988 26937 33762 6949 8943 12634 17986 22668 6657 8765 12823 18484 23658 9236 11739 16258 23064 28909 5950 7658 10818 15400 19410 6414 8445 12355 17810 22795 8899 11310 15665 22223 27854 5733 7378 10423 14838 18701 7097 9305 13478 19252 24344 10264 12646 17089 23168 28370 6771 8323 11370 15155 18511 6076 7968 11541 16485 20844 8789 10828 14633 19837 24292 5798 7127 9736 12976 15850 5855 7677 11120 15883 20084 8468 10433 14098 19113 23405 5586 6866 9380 12503 15271 174 169 160 148 137 191 179 160 146 133 187 177 160 145 131 149 145 137 127 118 163 153 137 125 114 160 151 137 124 112 144 139 132 122 113 157 147 132 120 109 154 146 132 119 108 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27H10K0-D-7x 97 BXRC-30C10K1-B-74 70 BXRC-30C10K1-C-74 70 BXRC-30C10K1-D-74 70 BXRC-30E10K0-B-7x 80 BXRC-30E10K0-C-7x 80 BXRC-30E10K0-D-7x 80 BXRC-30G1KH0-B-7X 90 BXRC-30G1KH0-C-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 5084 6543 9243 13159 16585 9464 12029 16661 23635 29625 11619 14954 21124 30073 37903 7731 9949 14055 20009 25219 8260 10876 15912 22937 29357 11461 14566 20175 28620 35873 7383 9502 13423 19110 24085 6997 9213 13478 19429 24867 9708 12339 17089 24243 30386 4954 6089 8319 11087 13543 9006 11096 14995 20328 24893 11321 13916 19012 25339 30951 7533 9259 12649 16860 20593 7540 9887 14321 20455 25865 10906 13437 18157 24615 30143 7194 8843 12081 16102 19668 6387 8375 12131 17327 21909 9238 11382 15380 20851 25533 137 129 117 106 96 212 199 178 162 147 205 195 178 163 149 208 196 178 161 146 185 180 170 157 146 203 190 170 155 141 198 188 170 154 139 157 152 144 133 124 172 161 144 131 119 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30G1KH0-D-7x 90 BXRC-30G10K0-B-7x 90 BXRC-30G10K0-C-7x 90 BXRC-30G10K0-D-7x 90 BXRC-30H10K0-D-7x 97 BXRC-30A10K1-B-73 93 BXRC-30A10K1-C-73 93 BXRC-30A10K1-D-73 93 BXRC-35E10K0-B-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 6254 8049 11370 16187 20402 6705 8829 12917 18619 23831 9303 11824 16377 23233 29120 5994 7714 10896 15513 19552 5429 6987 9870 14051 17710 6025 7933 11606 16730 21413 8359 10625 14716 20876 26166 5386 6931 9791 13939 17568 8455 11132 16286 23477 30047 6094 7491 10233 13639 16660 6121 8026 11625 16605 20997 8853 10907 14739 19982 24469 5840 7179 9807 13071 15966 5290 6502 8883 11840 14462 5500 7212 10446 14920 18867 7955 9801 13244 17955 21987 5248 6450 8812 11745 14346 7718 10119 14658 20937 26474 168 159 144 130 118 150 146 138 127 119 164 154 138 126 114 161 152 138 125 113 146 138 125 113 102 135 131 124 115 107 148 139 124 113 103 145 137 124 112 102 189 184 174 161 149 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 13 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-35E10K0-C-7x 80 BXRC-35E10K0-D-7x 80 BXRC-35G10K0-B-7x 90 BXRC-35G10K0-C-7x 90 BXRC-35G10K0-D-7x 90 BXRC-35A10K1-B-73 93 BXRC-35A10K1-C-73 93 BXRC-35A10K1-D-73 93 BXRC-40C10K1-B-74 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 11730 14909 20649 29294 36717 7557 9726 13739 19560 24652 6948 9149 13385 19294 24694 9640 12253 16970 24075 30175 6211 7993 11291 16075 20260 6414 8445 12355 17810 22795 8899 11310 15665 22223 27854 5733 7378 10423 14838 18701 8892 11708 17129 24691 31602 11162 13753 18584 25195 30852 7363 9051 12365 16481 20130 6343 8317 12046 17207 21757 9174 11302 15273 20706 25356 6052 7439 10162 13544 16544 5855 7677 11120 15883 20084 8468 10433 14098 19113 23405 5586 6866 9380 12503 15271 8117 10643 15416 22020 27843 207 194 174 158 144 203 192 174 157 143 156 151 143 132 123 170 160 143 130 119 167 158 143 129 117 144 139 132 122 113 157 147 132 120 109 154 146 132 119 108 199 193 183 169 157 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 14 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40C10K1-C-74 70 BXRC-40C10K1-D-74 70 BXRC-40E10K0-B-7x 80 BXRC-40E10K0-C-7x 80 BXRC-40E10K0-D-7x 80 BXRC-40G10K0-B-7X 90 BXRC-40G10K0-C-7X 90 BXRC-40G10K0-D-7X 90 BXRC-40H10K0-D-7x 97 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 1050 1400 2100 3150 4200 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 35.4 36.2 37.6 39.5 41.2 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 37.2 50.6 79.0 124.4 172.9 12337 15680 21717 30809 38616 7948 10229 14450 20571 25927 8503 11196 16380 23611 30220 11798 14995 20768 29462 36928 7601 9782 13818 19672 24794 7094 9341 13666 19699 25212 9843 12510 17326 24580 30808 6341 8161 11528 16412 20685 5733 7378 10423 14838 18701 11740 14464 19546 26498 32448 7744 9519 13005 17333 21172 7762 10178 14742 21057 26626 11227 13832 18691 25339 31030 7406 9103 12436 16575 20246 6476 8491 12299 17568 22214 9366 11540 15594 21140 25888 6179 7595 10375 13829 16891 5586 6866 9380 12503 15271 218 204 183 167 152 214 202 183 165 150 190 185 175 162 150 209 195 175 159 145 204 193 175 158 143 159 154 146 135 125 174 163 146 133 121 170 161 146 132 120 154 146 132 119 108 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 15 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40A10K1-B-73 93 BXRC-40A10K1-C-73 93 BXRC-40A10K1-D-73 93 BXRC-50C10K1-B-7x 70 BXRC-50C10K1-C-7x 70 BXRC-50C10K1-D-7x 70 BXRC-50E10K1-B-7x 80 BXRC-50E10K1-C-7x 80 BXRC-50E10K1-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 6948 9149 13385 19294 24694 9640 12253 16970 24075 30175 6211 7993 11291 16075 20260 8941 11772 17222 24826 31774 12404 15766 21836 30977 38827 7991 10285 14529 20684 26069 8600 11324 16567 23881 30565 11932 15166 21005 29799 37350 7687 9894 13976 19897 25077 6343 8317 12046 17207 21757 9174 11302 15273 20706 25356 6052 7439 10162 13544 16544 8161 10701 15500 22140 27995 11804 14543 19652 26643 32625 7787 9571 13076 17428 21287 7851 10294 14910 21298 26930 11355 13990 18905 25629 31384 7490 9207 12578 16765 20478 156 151 143 132 123 170 160 143 130 119 167 158 143 129 117 200 194 184 170 158 219 206 184 167 153 215 203 184 166 151 193 187 177 164 152 211 198 177 161 147 207 195 177 160 145 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 16 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-50G10K1-B-7x 90 BXRC-50G10K1-C-7x 90 BXRC-50G10K1-D-7x 90 BXRC-56G10K0-B-7x 80 BXRC-56G10K0-C-7x 80 BXRC-56G10K0-D-7x 80 BXRC-56H10K1-D-74 97 BXRC-57C10K1-B-7x 70 BXRC-57C10K1-C-7x 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 7434 9789 14321 20643 26421 10315 13110 18157 25758 32285 6645 8552 12081 17199 21677 7483 9853 14414 20778 26594 10382 13195 18276 25926 32496 6689 8608 12160 17311 21818 6037 7770 10975 15625 19693 8698 11452 16754 24151 30911 12067 15337 21243 30135 37772 6786 8898 12889 18410 23279 9815 12093 16341 22154 27129 6475 7959 10873 14492 17701 6831 8956 12973 18530 23431 9879 12172 16448 22299 27306 6517 8011 10944 14586 17817 5882 7231 9878 13166 16081 7939 10410 15079 21538 27235 11483 14148 19118 25919 31739 166 162 153 141 131 182 171 153 139 127 179 169 153 138 125 168 163 154 142 132 183 172 154 140 128 180 170 154 139 126 162 153 139 126 114 195 189 179 165 154 213 200 179 163 148 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 17 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-57C10K1-D-7x 70 BXRC-57E10K1-B-7x 80 BXRC-57E10K1-C-7x 80 BXRC-57E10K1-D-7x 80 BXRC-65C10K1-B-7x 70 BXRC-65C10K1-C-7x 70 BXRC-65C10K1-D-7x 70 BXRC-65E10K1-B-7x 80 BXRC-65E10K1-C-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 7774 10005 14134 20122 25360 8260 10876 15912 22937 29357 11461 14566 20175 28620 35873 7383 9502 13423 19110 24085 8698 11452 16754 24151 30911 12067 15337 21243 30135 37772 7774 10005 14134 20122 25360 8357 11004 16099 23207 29702 11595 14738 20412 28957 36295 7575 9311 12720 16954 20709 7540 9887 14321 20455 25865 10906 13437 18157 24615 30143 7194 8843 12081 16102 19668 7939 10410 15079 21538 27235 11483 14148 19118 25919 31739 7575 9311 12720 16954 20709 7629 10003 14489 20696 26170 11034 13595 18371 24905 30498 209 198 179 162 147 185 180 170 157 146 203 190 170 155 141 198 188 170 154 139 195 189 179 165 154 213 200 179 163 148 209 198 179 162 147 187 182 172 159 148 205 192 172 157 143 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 18 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number BXRC-65E10K1-D-7x CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 80 1050 1400 2100 3150 4200 35.4 36.2 37.6 39.5 41.2 37.2 50.6 79.0 124.4 172.9 7470 9614 13581 19335 24369 7279 8947 12223 16291 19899 201 190 172 155 141 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 19 Electrical Characteristics Table 5: Electrical Characteristics Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Part Number BXRC-xxx10Kx-B-7x BXRC-xxx10Kx-C-7x BXRC-xxx10Kx-D-7x Drive Current (mA) Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) 0.06 46.1 57.5 -24.9 0.07 49.7 61.6 74.6 -33.2 0.04 61.5 76.8 74.4 80.0 -33.2 0.05 66.2 82.2 34.8 37.6 40.4 -17.4 0.06 33.4 41.6 38.1 41.2 44.3 -17.4 0.07 36.7 45.4 Minimum Typical Maximum 1800 48.1 52.0 55.9 -24.9 3600 51.7 55.8 60.0 1710 64.2 69.4 3420 68.8 2100 4200 Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. 20 Eye Safety Table 6: Eye Safety Risk Group (RG) Classifications Part Number BXRC-xxx10Kx-B-7x BXRC-xxx10Kx-C-7x BXRC-xxx10Kx-D-7x CCT1,5 Drive Current 5 (mA) 2700K/3000K 4000K2 5000K3 6500K4 1800 RG1 RG1 RG1 RG1 2700 RG1 RG1 RG2 RG2 3600 RG1 RG1 RG2 RG2 1710 RG1 RG1 RG1 RG2 2565 RG1 RG1 RG2 RG2 3420 RG1 RG2 RG2 RG2 2100 RG1 RG1 RG1 RG1 3150 RG1 RG1 RG1 RG2 4200 RG1 RG1 RG2 RG2 Notes for Table 6: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed . 21 Absolute Maximum Ratings Table 7: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx10Kx-B-7x BXRC-xxx10Kx-C-7x BXRC-xxx10Kx-D-7x Maximum Drive Current3 3600mA 3420mA 4200mA Maximum Peak Pulsed Drive Current4,5 5140mA 4890mA 6000mA Maximum Reverse Voltage6 -90V -120V -65V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Per IEC 62031, LED Modules for General Lighting - Safety Specifications, the maximum allowable current when using the Molex Pico Connector is 3150mA. 5. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 6. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 22 Performance Curves Figure 2: Vero 29C Drive Current vs. Voltage 4000 4000 3500 3500 3000 3000 Forward Current (mA) Forward Current (mA) Figure 1: Vero 29B Drive Current vs. Voltage 2500 2000 1500 1000 2500 2000 1500 1000 500 0 500 47 48 49 50 51 52 53 54 55 56 57 0 58 63 64 65 66 67 68 Forward Voltage (V) Figure 3: Vero 29D Drive Current vs. Voltage 71 72 73 74 75 76 200% 180% 4000 160% Relative Luminous Flux 3500 Forward Current (mA) 70 Figure 4: Vero 29B Typical Relative Flux vs. Current 4500 3000 2500 2000 1500 1000 140% 120% 100% 80% 60% 40% 500 0 69 Forward Voltage (V) 20% 33 34 35 36 37 38 39 40 41 42 0% 0 Forward Voltage (V) 500 1000 1500 2000 2500 3000 3500 4000 Forward Current (mA) Figure 6: Vero 29D Typical Relative Flux vs. Current 200% 200% 180% 180% 160% 160% 140% 140% Relative Luminous Flux Relative Luminous Flux Figure 5: Vero 29C Typical Relative Flux vs. Current 120% 100% 80% 60% 120% 100% 80% 60% 40% 40% 20% 20% 0% 0 400 800 1200 1600 2000 2400 Forward Current (mA) 2800 3200 3600 4000 0% 0 500 1000 1500 2000 2500 3000 3500 4000 4500 Forward Current (mA) Notes for Figures 1-6: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 23 Performance Curves Figure 8: Typical DC ccy Shift vs. Case Temperature Figure 7: Typical DC Flux vs. Case Temperature 0 103% Neutral White 50 75 100 125 0.000 Cool White 25°C Pulsed 97% -0.003 ccy Shift Relative Luminous Flux 100% 25 0.003 Warm White 94% 91% -0.006 -0.009 88% Warm White -0.012 85% -0.015 82% 0 25 50 75 100 Neutral White Cool White 25°C Pulsed 125 Case Temperature (°C) Case Temperature (°C) Figure 10: 2000K, 65 CRI Color Shift vs. Case Temperature Figure 9: Typical DC ccx Shift vs. Case Temperature 0.4101 0 25 50 75 100 0.41 125 0.4099 0.000 0.4098 -0.002 Pulsed Center Point Tc=25°C 15°C 25°C 0.4097 ccy ccx Shift -0.004 -0.006 65°C 0.4093 Warm White -0.012 0.4095 0.4094 -0.008 -0.010 45°C 0.4096 Neutral White 85°C 0.4092 Cool White 25°C Pulsed 105°C 0.4091 Case Temperature (°C) 0.409 0.525 0.526 0.527 0.528 0.529 0.53 0.531 0.532 ccx Notes for Figures 7 - 9: 1. Characteristics shown for warm white based on 3000K and 80 CRI. 2. Characteristics shown for neutral white based on 4000K and 80 CRI. 3. Characteristics shown for cool white based on 5000K and 70 CRI. 4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information. 24 Performance Curves Figure 11: 1750K Color Shift vs. Case Temperature1 Figure 12: 2500K Color Shift vs. Case Temperature1 0.3705 0.4145 Pulsed Center Point Tc = 25°C 15°C 0.37 15°C 0.414 25°C 0.4135 25°C 0.413 0.3695 0.369 ccy ccy 45°C 85°C 0.411 105°C 0.5198 0.52 70°C 85°C 0.4115 0.3685 0.368 0.5196 45°C 0.4125 0.412 70°C 0.5202 0.5204 105°C 0.4105 0.468 0.5206 0.47 0.472 0.474 0.369 15°C 0.342 0.34 0.367 0.332 70°C 0.33 0.365 0.364 70°C 0.363 85°C 0.328 Pulsed Center Point Tc=25°C 45°C 45°C 0.334 ccy ccy 25°C 0.366 0.336 0.326 0.368 Pulsed Center Point Tc = 25°C 25°C 0.338 0.478 Figure 14: 3000K, Class A Color Shift vs. Case Temperature1 0.344 15°C 0.476 ccx ccx Figure 13: 5600K Color Shift vs. Case Temperature1,3 Pulsed Center Point Tc = 25°C 85°C 0.362 105°C 0.361 0.324 0.322 0.32 0.322 0.324 0.326 0.328 105°C 0.36 0.416 0.33 0.4165 0.417 ccx Figure 15: 3500K, Class A Color Shift vs. Case Temperature1 ccx 0.4175 0.418 0.4185 Figure 16: 4000K, Class A Color Shift vs. Case Temperature1 0.37 0.3760 15°C 0.368 Pulsed Center Point Tc=25°C 25°C 0.366 15°C 0.3740 25°C 0.3720 45°C 45°C ccy 0.3700 ccy Pulsed Center Point Tc=25°C 0.364 0.3680 70°C 0.362 85°C 0.36 85°C 0.3640 105°C 0.358 0.392 70°C 0.3660 105°C 0.393 0.394 0.395 0.396 0.397 ccx 0.3620 0.373 0.374 0.375 0.376 ccx 0.377 0.378 0.379 Note for Figures 10-16: 1. Measurements made under DC test conditions at the nominal drive current. 2. Typical color shift is shown with a tolerance of ±0.002. 3. Color shift shown for product hot targeted at Tc=85°C 25 Performance Curves Figure 17: Vero 29D Drive Current Derating Curve 4400 Drive Current (mA) 4200 4000 3960 3800 3600 3400 Max Drive Current LM-80 Max Drive Current 3200 0 10 20 30 40 50 60 70 80 90 100 110 Case Temperature (⁰C) Notes for Figure 17: 1. The maximum allowable drive current for the Vero 29D product is dependent on the operating case temperature. Please refer to the Product Feature Map (page 2) for the location of the Tc Point 2. LM-80 Max Drive Current must not be exceeded in order to meet LM-80 lifetime projections. 3. Lumen maintenance (L70) and lifetime predictions are valid for drive current and case temperature conditions used for LM-80 testing as included in the applicable LM-80 test report for these products. Contact your Bridgelux sales representative for LM-80 report. 26 Typical Radiation Pattern Figure 18: Typical Spatial Radiation Pattern Note for Figure 18: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value. Figure 19: Typical Polar Radiation Pattern 27 Typical Color Spectrum Figure 20: Typical Color Spectrum 110% 3000K 100% 4000K 5000K Relative Spectral Power Distribution 90% 6500K 80% 70% 60% 50% 40% 30% 20% 10% 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 20: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. Figure 21: Typical Color Spectrum for Vero 29 with Décor Series 1 17E 20B 0.9 25E 27H Relative Spectral Power Distribution 0.8 30H 56G 0.7 56H 0.6 0.5 0.4 0.3 0.2 0.1 0 400 450 500 550 600 Wavelength (nm) 650 700 750 800 Note for Figure 21: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 28 Mechanical Dimensions Figure 22: Drawing for Vero 29 LED Array Notes for Figure 22: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ± 0.10mm. 4. Mounting holes (4X) are for M3 screws. 5. Bridgelux recommends four tapped holes for mounting screws with 43.0 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 29 Color Binning Information Figure 23: Graph of Warm and Neutral White Test Bins in xy Color Space 0.44 2500K 4SDCM 3 SDCM 4 SDCM 2000K 3SDCM 2700K 0.42 3000K 3500K 0.4 Y 4000K 1750K 4SDCM 0.38 0.36 0.34 0.36 0.39 0.42 0.45 X 0.48 0.51 0.54 Note: Pulsed Test Conditions, Tc = 25°C Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 1750K 2000K 2500K 2700K ANSI Bin (for reference only) - - - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - - - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - - - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.5167, 0.336) (0.5280, 0.4100) (0.4765, 0.4137) (0.4578, 0.4101) 3000K1 (0.4338, 0.403) 3500K1 4000K1 (0.4073, 0.3917) (0.3818, 0.3797) Note for Table 8: 1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information. Figure 24: Graph of Cool White Test Bins in xy Color Space 0.39 4 SDCM 3 SDCM 0.38 0.37 5000K 0.36 5700K Y 0.35 0.34 6500K 0.33 0.32 0.31 0.3 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Bin Code 5000K 5600K1 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5310K - 6020K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5475K - 5830K) (5829K - 5481K) (6270K - 6765K) 73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (5490K - 5820K) (6250K - 6745K) Center Point (x,y) (0.3447, 0.3553) (0.3293, 0.3423) (0.3287, 0.3417) (0.3123, 0.3282) Note for Table 9: 1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C. 30 Packaging and Labeling Figure 25: Drawing for Vero 29 Packaging Tray Notes for Figure 25: 1. Dimensions are in millimeters. 2. Drawings are not to scale. 31 Packaging and Labeling Figure 26: Vero Series Packaging and Labeling Notes for Figure 26: 1. Each tray holds 50 COBs. 2. Each tray is vacuum sealed in an anti-static bag and placed in its own box. 3. Each tray, bag and box is to be labeled as shown above. Figure 27: Gen. 7 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E10K0C 73 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 32 Design Resources Application Notes 3D CAD Models Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. Optical Source Models LM80 Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. Precautions CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN31 for additional information. CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. Disclaimers MINOR PRODUCT CHANGE POLICY STANDARD TEST CONDITIONS The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Unless otherwise stated, array testing is performed at the nominal drive current. 33 About Bridgelux: Bridging Light and Life™ At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com © 2016-2019 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.. Bridgelux Gen 7 Vero 29 Array Series Product Data Sheet DS93 Rev. Q (03/2019) 34
BXRC-50E10K1-B-74 价格&库存

很抱歉,暂时无法提供与“BXRC-50E10K1-B-74”相匹配的价格&库存,您可以联系我们找货

免费人工找货