0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BXRC-40G10K0-B-72

BXRC-40G10K0-B-72

  • 厂商:

    BRIDGELUX

  • 封装:

    -

  • 描述:

    LEDCOBVERO294000KROUND

  • 数据手册
  • 价格&库存
BXRC-40G10K0-B-72 数据手册
Bridgelux Gen 7 Vero 29 Array ® ® Product Data Sheet DS93 1 Vero® Series Introduction Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and typical R9 value of 98, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen lamps Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series Food products are a must have for any butcher counter or bakery. Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these industries. Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Features • Efficacy of 170 lm/W typical • Lumen output performance ranges from 3,850 to 38,400 lumens • Broad range of CCT options from 1750K to 6500K • CRI options include minimum 65, 70, 80, and 90, 2 and 3 SDCM color control for 2700K-4000K CCT Benefits • Broad application coverage for interior and exterior lighting • Flexibility for application driven lighting design requirements • High quality true color reproduction • Uniform consistent white light • Reliable operation at up to 2X nominal drive current • Flexibility in design optimization • Radial die pattern and improved lumen density • Enhanced ease of use and assembly • Thermally isolated solder pads • Solderless connectivity enables plug & play installation and field upgradability • Onboard connector port • Top side part number markings • Vf bin code backside marking • Improved inventory management and quality control Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 10 Electrical Characteristics 20 Eye Safety 21 Absolute Maximum Ratings 22 Performance Curves 23 Typical Radiation Pattern 27 Typical Color Spectrum 28 Mechanical Dimensions 29 Color Binning Information 30 Packaging and Labeling 31 Design Resources 33 Precautions 33 Disclaimers 33 About Bridgelux 34 1 Product Feature Map Vero 29 is the largest form factor in the Vero family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. Mounting holes Thermally isolated solder pads reduce manufacturing cycle time and complexity Polarity indication marks simplify manufacturing operator instructions Tc Measurement point 2D Bar code provides full manufacturing traceability Top side part number marking improves inventory management and outgoing quality control Radial die configuration improves lumen density and beam control Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Optional Molex Pico-EZmate™ connector harness (sold separately) Product Nomenclature The part number designation for Bridgelux Vero LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 BXRC – 30 E 10K 0 – C – 7 3 CCT Bin Options Product Family Nominal CCT 17 = 1,750K 20 = 2,000K 25 = 2,500K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 56 = 5,600K 57 = 5,700K 65 = 6,500K Gen. 7 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Array Configuration CRI B = 65 CRI min. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted Flux Indicator 10Kx = 10,000 lm 2 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) BXRC-17E10K0-B-74 1750 80 1800 8611 7750 BXRC-17E10K0-C-74 1750 80 1710 10918 9826 Typical Power (W) Typical Efficacy (lm/W) 52.0 93.6 92 69.4 118.7 92 Typical Vf (V) BXRC-17E10K0-D-74 1750 80 2100 7264 6538 37.6 79.0 92 BXRC-20B10K1-C-73 2000 65 1710 18632 16769 69.4 118.7 157 BXRC-20B10K1-D-73 2000 65 2100 12397 11157 37.6 79.0 157 BXRC-25E10K0-B-74 2500 80 1800 14321 12889 52.0 93.6 153 153 BXRC-25E10K0-C-74 2500 80 1710 18157 16341 69.4 118.7 BXRC-25E10K0-D-74 2500 80 2100 12081 10873 37.6 79.0 153 BXRC-27E10K0-B-7x 2700 80 1800 14976 13478 52.0 93.6 160 BXRC-27E10K0-C-7x 2700 80 1710 18988 17089 69.4 118.7 160 BXRC-27E10K0-D-7x 2700 80 2100 12634 11370 37.6 79.0 160 BXRC-27G1KH0-B-7x 2700 90 1800 12823 11541 52.0 93.6 137 BXRC-27G1KH0-C-7x 2700 90 1710 16258 14633 69.4 118.7 137 BXRC-27G1KH0-D-7x 2700 90 2100 10818 9736 37.6 79.0 137 BXRC-27G10K0-B-7x 2700 90 1800 12355 11120 52.0 93.6 132 BXRC-27G10K0-C-7x 2700 90 1710 15665 14098 69.4 118.7 132 BXRC-27G10K0-D-7x 2700 90 2100 10423 9380 37.6 79.0 132 BXRC-27H10K0-D-7x 2700 97 2100 9243 8319 37.6 79.0 117 BXRC-30C10K1-B-74 3000 70 1800 16661 14995 52.0 93.6 178 BXRC-30C10K1-C-74 3000 70 1710 21124 19012 69.4 118.7 178 BXRC-30C10K1-D-74 3000 70 2100 14055 12649 37.6 79.0 178 BXRC-30E10K0-B-7x10 3000 80 1800 15912 14321 52.0 93.6 170 BXRC-30E10K0-C-7x10 3000 80 1710 20175 18157 69.4 118.7 170 BXRC-30E10K0-D-7x10 3000 80 2100 13423 12081 37.6 79.0 170 BXRC-30G1KH0-B-7x 3000 90 1800 13478 12131 52.0 93.6 144 BXRC-30G1KH0-C-7x 3000 90 1710 17089 15380 69.4 118.7 144 BXRC-30G1KH0-D-7x 3000 90 2100 11370 10233 37.6 79.0 144 BXRC-30G10K0-B-7x 3000 90 1800 12917 11625 52.0 93.6 138 BXRC-30G10K0-C-7x 3000 90 1710 16377 14739 69.4 118.7 138 BXRC-30G10K0-D-7x 3000 90 2100 10896 9807 37.6 79.0 138 BXRC-30H10K0-D-7x 3000 97 2100 9870 8883 37.6 79.0 125 BXRC-30A10K1-B-738,9 3000 93 1800 11606 10446 52.0 93.6 124 BXRC-30A10K1-C-73 8,9 3000 93 1710 14716 13244 69.4 118.7 124 BXRC-30A10K1-D-738,9 3000 93 2100 9791 8812 37.6 79.0 124 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions. 3 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E10K0-B-7x10 3500 80 1800 16286 14658 52.0 93.6 174 BXRC-35E10K0-C-7x10 3500 80 1710 20649 18584 69.4 118.7 174 BXRC-35E10K0-D-7x10 3500 80 2100 13739 12365 37.6 79.0 174 BXRC-35G10K0-B-7x 3500 90 1800 13385 12046 52.0 93.6 143 BXRC-35G10K0-C-7x 3500 90 1710 16970 15273 69.4 118.7 143 BXRC-35G10K0-D-7x 3500 90 2100 11291 10162 37.6 79.0 143 BXRC-35A10K1-B-738,9 3500 93 1800 12355 11120 52.0 93.6 132 BXRC-35A10K1-C-738,9 3500 93 1710 15665 14098 69.4 118.7 132 BXRC-35A10K1-D-738,9 3500 93 2100 10423 9380 37.6 79.0 132 BXRC-40C10K1-B-74 4000 70 1800 17129 15416 52.0 93.6 183 BXRC-40C10K1-C-74 4000 70 1710 21717 19546 69.4 118.7 183 BXRC-40C10K1-D-74 4000 70 2100 14450 13005 37.6 79.0 183 BXRC-40E10K0-B-7x10 4000 80 1800 16380 14742 52.0 93.6 175 BXRC-40E10K0-C-7x10 4000 80 1710 20768 18691 69.4 118.7 175 BXRC-40E10K0-D-7x10 4000 80 2100 13818 12436 37.6 79.0 175 BXRC-40G10K0-B-7x 4000 90 1800 13666 12299 52.0 93.6 146 BXRC-40G10K0-C-7x 4000 90 1710 17326 15594 69.4 118.7 146 BXRC-40G10K0-D-7x 4000 90 2100 11528 10375 37.6 79.0 146 BXRC-40H10K0-D-7x 4000 97 2100 10423 9380 37.6 79.0 132 BXRC-40A10K1-B-738,9 4000 93 1800 13385 12046 52.0 93.6 143 143 BXRC-40A10K1-C-738,9 4000 93 1710 16970 15273 69.4 118.7 BXRC-40A10K1-D-738,9 4000 93 2100 11291 10162 37.6 79.0 143 BXRC-50C10K1-B-7x10 5000 70 1800 17222 15500 52.0 93.6 184 BXRC-50C10K1-C-7x10 5000 70 1710 21836 19652 69.4 118.7 184 BXRC-50C10K1-D-7x10 5000 70 2100 14529 13076 37.6 79.0 184 BXRC-50E10K1-B-7x 5000 80 1800 16567 14910 52.0 93.6 177 BXRC-50E10K1-C-7x 5000 80 1710 21005 18905 69.4 118.7 177 BXRC-50E10K1-D-7x 5000 80 2100 13976 12578 37.6 79.0 177 BXRC-50G10K1-B-7x 5000 90 1800 14321 12889 52.0 93.6 153 BXRC-50G10K1-C-7x 5000 90 1710 18157 16341 69.4 118.7 153 BXRC-50G10K1-D-7x 5000 90 2100 12081 10873 37.6 79.0 153 BXRC-56G10K0-B-74 5600 90 1800 14414 12973 52.0 93.6 154 154 BXRC-56G10K0-C-74 5600 90 1710 18276 16448 69.4 118.7 BXRC-56G10K0-D-74 5600 90 2100 12160 10944 37.6 79.0 154 BXRC-56H10K1-D-74 5600 97 2100 10975 9878 37.6 79.0 139 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions. 4 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C10K1-B-7x10 5700 70 1800 16754 15079 52.0 93.6 179 BXRC-57C10K1-C-7x10 5700 70 1710 21243 19118 69.4 118.7 179 BXRC-57C10K1-D-7x10 5700 70 2100 14134 12720 37.6 79.0 179 BXRC-57E10K1-B-7x10 5700 80 1800 15912 14321 52.0 93.6 170 BXRC-57E10K1-C-7x10 5700 80 1710 20175 18157 69.4 118.7 170 BXRC-57E10K1-D-7x10 5700 80 2100 13423 12081 37.6 79.0 170 BXRC-65C10K1-B-7x10 6500 70 1800 16754 15079 52.0 93.6 179 BXRC-65C10K1-C-7x10 6500 70 1710 21243 19118 69.4 118.7 179 BXRC-65C10K1-D-7x10 6500 70 2100 14134 12720 37.6 79.0 179 BXRC-65E10K1-B-7x10 6500 80 1800 16099 14489 52.0 93.6 172 BXRC-65E10K1-C-7x10 6500 80 1710 20412 18371 69.4 118.7 172 BXRC-65E10K1-D-7x10 6500 80 2100 13581 12223 37.6 79.0 172 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions. 5 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A10K1-B-73 3000 80 93 1800 10794 9715 50.9 91.6 118 118 BXRC-30A10K1-C-73 3000 80 93 1710 13685 12317 67.9 116.1 BXRC-30A10K1-D-73 3000 80 93 2100 9106 8195 36.8 77.3 118 BXRC-35A10K1-B-73 3500 80 93 1800 11490 10341 50.9 91.6 125 126 BXRC-35A10K1-C-73 3500 80 93 1710 14568 13112 67.9 116.1 BXRC-35A10K1-D-73 3500 80 93 2100 9693 8724 36.8 77.3 125 BXRC-40A10K1-B-73 4000 80 93 1800 12448 11203 50.9 91.6 136 BXRC-40A10K1-C-73 4000 80 93 1710 15782 14204 67.9 116.1 136 BXRC-40A10K1-D-73 4000 80 93 2100 10501 9451 36.8 77.3 136 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 85 BXRC-17E10K0-B-74 1750 80 1800 7750 6975 50.7 91.2 BXRC-17E10K0-C-74 1750 80 1710 9826 8844 68.1 116.4 84 BXRC-17E10K0-D-74 1750 80 2100 6538 5884 36.6 76.8 85 BXRC-20B10K0-C-73 2000 65 1710 16769 15092 68.1 116.4 144 BXRC-20B10K0-D-73 2000 65 2100 11157 10041 36.6 76.8 145 BXRC-25E10K0-B-74 2500 80 1800 12889 11600 50.7 91.2 141 BXRC-25E10K0-C-74 2500 80 1710 16341 14707 68.1 116.4 140 BXRC-25E10K0-D-74 2500 80 2100 10873 9786 36.6 76.8 142 BXRC-27E10K0-B-7x 2700 80 1800 13478 12131 50.7 91.2 148 BXRC-27E10K0-C-7x 2700 80 1710 17089 15380 68.1 116.4 147 BXRC-27E10K0-D-7x 2700 80 2100 11370 10233 36.6 76.8 148 BXRC-27G1KH0-B-7x 2700 90 1800 11541 10387 51.0 91.7 126 BXRC-27G1KH0-C-7x 2700 90 1710 14633 13169 68.4 116.9 125 BXRC-27G1KH0-D-7x 2700 90 2100 9736 8762 36.6 76.8 127 121 BXRC-27G10K0-B-7x 2700 90 1800 11120 10008 51.0 91.7 BXRC-27G10K0-C-7x 2700 90 1710 14098 12689 68.4 116.9 121 BXRC-27G10K0-D-7x 2700 90 2100 9380 8442 36.6 76.8 122 BXRC-27H10K0-D-7x 2700 97 2100 8319 7487 36.6 76.8 108 BXRC-30C10K1-B-74 3000 70 1800 14995 13495 51.0 91.7 163 BXRC-30C10K1-C-74 3000 70 1710 19012 17110 68.4 116.9 163 BXRC-30C10K1-D-74 3000 70 2100 12649 11384 36.6 76.8 165 BXRC-30E10K0-B-7x 3000 80 1800 14321 12889 51.0 91.7 156 BXRC-30E10K0-C-7x 3000 80 1710 18157 16341 68.4 116.9 155 BXRC-30E10K0-D-7x 3000 80 2100 12081 10873 36.6 76.8 157 BXRC-30G1KH0-B-7x 3000 90 1800 12131 10918 51.0 91.7 132 BXRC-30G1KH0-C-7x 3000 90 1710 15380 13842 68.4 116.9 132 BXRC-30G1KH0-D-7x 3000 90 2100 10233 9210 36.6 76.8 133 127 BXRC-30G10K0-B-7x 3000 90 1800 11625 10463 50.7 91.2 BXRC-30G10K0-C-7x 3000 90 1710 14739 13265 68.1 116.4 127 BXRC-30G10K0-D-7x 3000 90 2100 9807 8826 36.6 76.8 128 BXRC-30H10K0-D-7X 3000 97 2100 8883 7995 36.6 76.9 116 BXRC-30A10K1-B-737,8 3000 93 1800 10446 9401 50.7 91.2 115 BXRC-30A10K1-C-737,8 3000 93 1710 13244 11920 68.1 116.4 114 BXRC-30A10K1-D-737,8 3000 93 2100 8812 7931 36.6 76.8 115 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 7 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E10K0-B-7X 3500 80 1800 14658 13192 50.7 91.2 161 BXRC-35E10K0-C-7X 3500 80 1710 18584 16726 68.1 116.4 160 BXRC-35E10K0-D-7X 3500 80 2100 12365 11129 36.6 76.8 161 BXRC-35G10K0-B-7X 3500 90 1800 12046 10842 50.7 91.2 132 BXRC-35G10K0-C-7X 3500 90 1710 15273 13746 68.1 116.4 131 BXRC-35G10K0-D-7X 3500 90 2100 10162 9146 36.6 76.8 132 BXRC-35A10K1-B-737,8 3500 93 1800 11120 10008 50.7 91.2 122 BXRC-35A10K1-C-737,8 3500 93 1710 14098 12689 68.1 116.4 121 BXRC-35A10K1-D-73 3500 93 2100 9380 8442 36.6 76.8 122 BXRC-40C10K1-B-74 4000 70 1800 15416 13874 51.0 91.7 168 7,8 BXRC-40C10K1-C-74 4000 70 1710 19546 17591 68.4 116.9 167 BXRC-40C10K1-D-74 4000 70 2100 13005 11704 36.6 76.8 169 162 BXRC-40E10K0-B-7X 4000 80 1800 14742 13268 50.7 91.2 BXRC-40E10K0-C-7X 4000 80 1710 18691 16822 68.1 116.4 161 BXRC-40E10K0-D-7X 4000 80 2100 12436 11193 36.6 76.8 162 135 BXRC-40G10K0-B-7X 4000 90 1800 12299 11069 50.7 91.2 BXRC-40G10K0-C-7X 4000 90 1710 15594 14034 68.1 116.4 134 BXRC-40G10K0-D-7X 4000 90 2100 10375 9338 36.6 76.8 135 BXRC-40H10K0-D-7x 4000 97 2100 9380 8442 36.6 76.9 122 BXRC-40A10K1-B-737,8 4000 93 1800 12046 10842 50.7 91.2 132 BXRC-40A10K1-C-737,8 4000 93 1710 15273 13746 68.1 116.4 131 BXRC-40A10K1-D-737,8 4000 93 2100 10162 9146 36.6 76.8 132 BXRC-50C10K1-B-7x 5000 70 1800 15500 13950 50.7 91.2 170 BXRC-50C10K1-C-7x 5000 70 1710 19652 17687 68.1 116.4 169 BXRC-50C10K1-D-7x 5000 70 2100 13076 11768 36.6 76.8 170 BXRC-50E10K1-B-7x 5000 80 1800 14910 13419 50.7 91.2 163 BXRC-50E10K1-C-7x 5000 80 1710 18905 17014 68.1 116.4 162 BXRC-50E10K1-D-7x 5000 80 2100 12578 11320 36.6 76.8 164 BXRC-50G10K1-B-7x 5000 90 1800 12889 11600 50.7 91.2 141 BXRC-50G10K1-C-7x 5000 90 1710 16341 14707 68.1 116.4 140 BXRC-50G10K1-D-7x 5000 90 2100 10873 9786 36.6 76.8 142 BXRC-56G10K0-B-74 5600 90 1800 12973 11676 50.7 91.2 142 BXRC-56G10K0-C-74 5600 90 1710 16448 14803 68.1 116.4 141 BXRC-56G10K0-D-74 5600 90 2100 10944 9849 36.6 76.8 143 BXRC-56H10K1-D-74 5600 97 2100 9878 8890 36.6 76.9 129 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 8 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 165 BXRC-57C10K1-B-7x 5700 70 1800 15079 13571 50.7 91.2 BXRC-57C10K1-C-7x 5700 70 1710 19118 17207 68.1 116.4 164 BXRC-57C10K1-D-7x 5700 70 2100 12720 11448 36.6 76.8 166 BXRC-57E10K1-B-7x 5700 80 1800 14321 12889 50.7 91.2 157 BXRC-57E10K1-C-7x 5700 80 1710 18157 16341 68.1 116.4 156 BXRC-57E10K1-D-7x 5700 80 2100 12081 10873 36.6 76.8 157 165 BXRC-65C10K1-B-7x 6500 70 1800 15079 13571 50.7 91.2 BXRC-65C10K1-C-7x 6500 70 1710 19118 17207 68.1 116.4 164 BXRC-65C10K1-D-7x 6500 70 2100 12720 11448 36.6 76.8 166 BXRC-65E10K1-B-7x 6500 80 1800 14489 13040 50.7 91.2 159 BXRC-65E10K1-C-7x 6500 80 1710 18371 16534 68.1 116.4 158 BXRC-65E10K1-D-7x 6500 80 2100 12223 11001 36.6 76.8 159 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 9 Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI BXRC-17E10K0-B-74 80 BXRC-17E10K0-C-74 80 BXRC-17E10K0-D-74 80 BXRC-20B10K0-C-73 65 BXRC-20B10K0-D-73 65 BXRC-25E10K0-B-74 80 BXRC-25E10K0-C-74 80 BXRC-25E10K0-D-74 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.7 78.9 124.4 173.0 56.6 76.7 118.7 185.0 254.6 37.2 50.7 78.9 124.4 173.0 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.7 78.9 124.4 173.0 4470 5886 8611 12413 15887 5665 7473 10918 15717 20113 3670 4854 7264 10608 13861 9667 12752 18632 26822 34323 6263 8283 12397 18102 23654 7434 9789 14321 20643 26421 9421 12427 18157 26138 33448 6103 8072 12081 17641 23051 4081 5350 7750 11070 13998 5176 6794 9826 13846 17281 3353 4413 6538 9345 11910 8832 11594 16769 23628 29491 5722 7530 11157 15947 20324 6786 8898 12889 18410 23279 8607 11298 16341 23026 28739 5576 7339 10873 15540 19806 100 97 92 85 79 100 97 92 85 79 99 96 92 85 80 171 166 157 145 135 168 163 157 145 137 166 162 153 141 131 167 162 153 141 131 164 159 153 142 133 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27E10K0-B-7x 80 BXRC-27E10K0-C-7x 80 BXRC-27E10K0-D-7x 80 BXRC-27G1KH0-B-7x 90 BXRC-27G1KH0-C-7x 90 BXRC-27G1KH0-D-7x 90 BXRC-27G10K0-B-7x 90 BXRC-27G10K0-C-7x 90 BXRC-27G10K0-D-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 7774 10237 14976 21588 27630 9852 12996 18988 27334 34979 6382 8441 12634 18448 24106 6657 8765 12823 18484 23658 8436 11128 16258 23405 29951 5465 7228 10818 15796 20641 6414 8445 12355 17810 22795 8128 10721 15665 22551 28857 5265 6964 10423 15220 19888 7097 9305 13478 19252 24344 9001 11815 17089 24080 30054 5831 7674 11370 16251 20712 6076 7968 11541 16485 20844 7707 10117 14633 20618 25734 4993 6571 9736 13915 17735 5855 7677 11120 15883 20084 7426 9747 14098 19866 24795 4811 6331 9380 13407 17088 174 169 160 148 137 174 169 160 148 137 172 167 160 148 139 149 145 137 127 118 149 145 137 127 118 147 143 137 127 119 144 139 132 122 113 144 140 132 122 113 142 138 132 122 115 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27H10K0-D-7x 97 BXRC-30C10K1-B-74 70 BXRC-30C10K1-C-74 70 BXRC-30C10K1-D-74 70 BXRC-30E10K0-B-7x 80 BXRC-30E10K0-C-7x 80 BXRC-30E10K0-D-7x 80 BXRC-30G1KH0-B-7X 90 BXRC-30G1KH0-C-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 4669 6176 9243 13497 17637 9464 12029 16661 23635 29625 10960 14458 21124 30409 38914 7100 9391 14055 20523 26818 8260 10876 15912 22937 29357 10468 13808 20175 29043 37165 6781 8969 13423 19601 25613 6997 9213 13478 19429 24867 8867 11696 17089 24601 31481 4266 5615 8319 11890 15154 9006 11096 14995 20328 24893 10014 13144 19012 26789 33435 6487 8538 12649 18080 23042 7540 9887 14321 20455 25865 9564 12554 18157 25585 31933 6195 8154 12081 17267 22007 6387 8375 12131 17327 21909 8101 10634 15380 21672 27049 125 122 117 109 102 212 199 178 162 147 194 188 178 164 153 191 185 178 165 155 185 180 170 157 146 185 180 170 157 146 182 177 170 158 148 157 152 144 133 124 157 152 144 133 124 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30G1KH0-D-7x 90 BXRC-30G10K0-B-7x 90 BXRC-30G10K0-C-7x 90 BXRC-30G10K0-D-7x 90 BXRC-30H10K0-D-7x 97 BXRC-30A10K1-B-73 93 BXRC-30A10K1-C-73 93 BXRC-30A10K1-D-73 93 BXRC-35E10K0-B-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 5744 7597 11370 16603 21695 6705 8829 12917 18619 23831 8497 11209 16377 23576 30169 5505 7280 10896 15911 20792 4986 6595 9870 14412 18833 6025 7933 11606 16730 21413 7635 10072 14716 21184 27109 4946 6542 9791 14297 18682 8455 11132 16286 23477 30047 5248 6907 10233 14626 18641 6121 8026 11625 16605 20997 7763 10191 14739 20769 25922 5029 6619 9807 14017 17864 4555 5996 8883 12696 16182 5500 7212 10446 14920 18867 6976 9157 13244 18662 23292 4519 5948 8812 12595 16052 7718 10119 14658 20937 26474 154 150 144 134 125 150 146 138 127 119 150 146 138 127 119 148 144 138 128 120 134 130 125 116 109 135 131 124 115 107 135 131 124 115 106 133 129 124 115 108 189 184 174 161 149 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 13 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-35E10K0-C-7x 80 BXRC-35E10K0-D-7x 80 BXRC-35G10K0-B-7x 90 BXRC-35G10K0-C-7x 90 BXRC-35G10K0-D-7x 90 BXRC-35A10K1-B-73 93 BXRC-35A10K1-C-73 93 BXRC-35A10K1-D-73 93 BXRC-40C10K1-B-74 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 10714 14133 20649 29726 38039 6941 9180 13739 20062 26215 6948 9149 13385 19294 24694 8805 11615 16970 24430 31262 5704 7544 11291 16488 21545 6414 8445 12355 17810 22795 8128 10721 15665 22551 28857 5265 6964 10423 15220 19888 8892 11708 17129 24691 31602 9789 12849 18584 26187 32684 6341 8346 12365 17673 22525 6343 8317 12046 17207 21757 8045 10560 15273 21521 26861 5211 6859 10162 14525 18512 5855 7677 11120 15883 20084 7426 9747 14098 19866 24795 4811 6331 9380 13407 17088 8117 10643 15416 22020 27843 189 184 174 161 149 187 181 174 161 152 156 151 143 132 123 156 151 143 132 123 153 149 143 133 125 144 139 132 122 113 144 140 132 122 113 142 138 132 122 115 199 193 183 169 157 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 14 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40C10K1-C-74 70 BXRC-40C10K1-D-74 70 BXRC-40E10K0-B-7x 80 BXRC-40E10K0-C-7x 80 BXRC-40E10K0-D-7x 80 BXRC-40G10K0-B-7X 90 BXRC-40G10K0-C-7X 90 BXRC-40G10K0-D-7X 90 BXRC-40H10K0-D-7x 97 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 1050 1400 2100 3150 4200 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 35.4 36.2 37.6 39.5 41.2 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 37.2 50.6 79.0 124.4 172.9 11268 14864 21717 31263 40007 7300 9654 14450 21100 27571 8503 11196 16380 23611 30220 10776 14214 20768 29897 38258 6981 9232 13818 20177 26366 7094 9341 13666 19699 25212 8990 11859 17326 24942 31918 5824 7702 11528 16834 21997 5265 6964 10423 15220 19888 10295 13514 19546 27541 34375 6669 8777 13005 18587 23690 7762 10178 14742 21057 26626 9845 12923 18691 26337 32872 6378 8394 12436 17775 22654 6476 8491 12299 17568 22214 8213 10781 15594 21973 27425 5321 7003 10375 14829 18900 4811 6331 9380 13407 17088 199 194 183 169 157 196 191 183 170 159 190 185 175 162 150 190 185 175 162 150 188 182 175 162 152 159 154 146 135 125 159 155 146 135 125 157 152 146 135 127 142 138 132 122 115 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 15 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40A10K1-B-73 93 BXRC-40A10K1-C-73 93 BXRC-40A10K1-D-73 93 BXRC-50C10K1-B-7x 70 BXRC-50C10K1-C-7x 70 BXRC-50C10K1-D-7x 70 BXRC-50E10K1-B-7x 80 BXRC-50E10K1-C-7x 80 BXRC-50E10K1-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 6948 9149 13385 19294 24694 8805 11615 16970 24430 31262 5704 7544 11291 16488 21545 8941 11772 17222 24826 31774 11330 14945 21836 31434 40226 7340 9707 14529 21215 27722 8600 11324 16567 23881 30565 10899 14376 21005 30238 38695 7060 9338 13976 20408 26667 6343 8317 12046 17207 21757 8045 10560 15273 21521 26861 5211 6859 10162 14525 18512 8161 10701 15500 22140 27995 10351 13587 19652 27691 34562 6706 8825 13076 18689 23819 7851 10294 14910 21298 26930 9957 13070 18905 26638 33248 6450 8490 12578 17978 22913 156 151 143 132 123 156 151 143 132 123 153 149 143 133 125 200 194 184 170 158 200 195 184 170 158 197 192 184 171 160 193 187 177 164 152 193 187 177 163 152 190 184 177 164 154 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 16 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-50G10K1-B-7x 90 BXRC-50G10K1-C-7x 90 BXRC-50G10K1-D-7x 90 BXRC-56G10K0-B-7x 80 BXRC-56G10K0-C-7x 80 BXRC-56G10K0-D-7x 80 BXRC-56H10K1-D-74 97 BXRC-57C10K1-B-7x 70 BXRC-57C10K1-C-7x 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 7434 9789 14321 20643 26421 9421 12427 18157 26138 33448 6103 8072 12081 17641 23051 7483 9853 14414 20778 26594 9483 12508 18276 26309 33667 6143 8125 12160 17756 23202 5545 7333 10975 16027 20942 8698 11452 16754 24151 30911 11022 14539 21243 30580 39132 6786 8898 12889 18410 23279 8607 11298 16341 23026 28739 5576 7339 10873 15540 19806 6831 8956 12973 18530 23431 8663 11372 16448 23177 28927 5612 7386 10944 15642 19936 5066 6667 9878 14118 17994 7939 10410 15079 21538 27235 10070 13218 19118 26939 33623 166 162 153 141 131 167 162 153 141 131 164 159 153 142 133 168 163 154 142 132 168 163 154 142 132 165 160 154 143 134 149 145 139 129 121 195 189 179 165 154 195 190 179 165 154 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 17 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-57C10K1-D-7x 70 BXRC-57E10K1-B-7x 80 BXRC-57E10K1-C-7x 80 BXRC-57E10K1-D-7x 80 BXRC-65C10K1-B-7x 70 BXRC-65C10K1-C-7x 70 BXRC-65C10K1-D-7x 70 BXRC-65E10K1-B-7x 80 BXRC-65E10K1-C-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 7140 9443 14134 20639 26969 8260 10876 15912 22937 29357 10468 13808 20175 29043 37165 6781 8969 13423 19601 25613 8698 11452 16754 24151 30911 11022 14539 21243 30580 39132 7140 9443 14134 20639 26969 8357 11004 16099 23207 29702 10591 13970 20412 29384 37602 6523 8586 12720 18181 23172 7540 9887 14321 20455 25865 9564 12554 18157 25585 31933 6195 8154 12081 17267 22007 7939 10410 15079 21538 27235 10070 13218 19118 26939 33623 6523 8586 12720 18181 23172 7629 10003 14489 20696 26170 9676 12701 18371 25886 32308 192 186 179 166 156 185 180 170 157 146 185 180 170 157 146 182 177 170 158 148 195 189 179 165 154 195 190 179 165 154 192 186 179 166 156 187 182 172 159 148 187 182 172 159 148 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 18 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number BXRC-65E10K1-D-7x CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 80 1050 1400 2100 3150 4200 35.4 36.2 37.6 39.5 41.2 37.2 50.6 79.0 124.4 172.9 6861 9074 13581 19831 25914 6268 8250 12223 17470 22266 184 179 172 159 150 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 19 Electrical Characteristics Table 5: Electrical Characteristics Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Part Number BXRC-xxx10Kx-B-7x BXRC-xxx10Kx-C-7x BXRC-xxx10Kx-D-7x Drive Current (mA) Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) 0.06 46.1 57.5 -24.9 0.07 49.7 61.6 74.6 -33.2 0.04 61.5 76.8 74.4 80.0 -33.2 0.05 66.2 82.2 34.8 37.6 40.4 -17.4 0.06 33.4 41.6 38.1 41.2 44.3 -17.4 0.07 36.7 45.4 Minimum Typical Maximum 1800 48.1 52.0 55.9 -24.9 3600 51.7 55.8 60.0 1710 64.2 69.4 3420 68.8 2100 4200 Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. 20 Eye Safety Table 6: Eye Safety Risk Group (RG) Classifications Part Number BXRC-xxx10Kx-B-7x BXRC-xxx10Kx-C-7x BXRC-xxx10Kx-D-7x CCT1,5 Drive Current 5 (mA) 2700K/3000K 4000K2 5000K3 6500K4 1800 RG1 RG1 RG1 RG1 2700 RG1 RG1 RG2 RG2 3600 RG1 RG1 RG2 RG2 1710 RG1 RG1 RG1 RG2 2565 RG1 RG1 RG2 RG2 3420 RG1 RG2 RG2 RG2 2100 RG1 RG1 RG1 RG1 3150 RG1 RG1 RG1 RG2 4200 RG1 RG1 RG2 RG2 Notes for Table 6: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed . 21 Absolute Maximum Ratings Table 7: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx10Kx-B-7x BXRC-xxx10Kx-C-7x BXRC-xxx10Kx-D-7x Maximum Drive Current3 3600mA 3420mA 4200mA Maximum Peak Pulsed Drive Current4,5 5140mA 4890mA 6000mA Maximum Reverse Voltage6 -90V -120V -65V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Per IEC 62031, LED Modules for General Lighting - Safety Specifications, the maximum allowable current when using the Molex Pico Connector is 3150mA. 5. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 6. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 22 Performance Curves Figure 2: Vero 29C Drive Current vs. Voltage 4000 4000 3500 3500 3000 3000 Forward Current (mA) Forward Current (mA) Figure 1: Vero 29B Drive Current vs. Voltage 2500 2000 1500 1000 2500 2000 1500 1000 500 0 500 47 48 49 50 51 52 53 54 55 56 57 0 58 63 64 65 66 67 68 Forward Voltage (V) Figure 3: Vero 29D Drive Current vs. Voltage 71 72 73 74 75 76 200% 180% 4000 160% Relative Luminous Flux 3500 Forward Current (mA) 70 Figure 4: Vero 29B Typical Relative Flux vs. Current 4500 3000 2500 2000 1500 1000 140% 120% 100% 80% 60% 40% 500 0 69 Forward Voltage (V) 20% 33 34 35 36 37 38 39 40 41 42 0% 0 Forward Voltage (V) 500 1000 1500 2000 2500 3000 3500 4000 Forward Current (mA) Figure 6: Vero 29D Typical Relative Flux vs. Current 200% 200% 180% 180% 160% 160% 140% 140% Relative Luminous Flux Relative Luminous Flux Figure 5: Vero 29C Typical Relative Flux vs. Current 120% 100% 80% 60% 120% 100% 80% 60% 40% 40% 20% 20% 0% 0 400 800 1200 1600 2000 2400 Forward Current (mA) 2800 3200 3600 4000 0% 0 500 1000 1500 2000 2500 3000 3500 4000 4500 Forward Current (mA) Notes for Figures 1-6: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 23 Performance Curves Figure 8: Typical DC ccy Shift vs. Case Temperature Figure 7: Typical DC Flux vs. Case Temperature 103% Neutral White 100% 25°C Pulsed 25 50 75 100 125 -0.003 94% 91% -0.006 -0.009 88% Warm White -0.012 85% 82% 0 0.000 Cool White 97% ccy Shift Relative Luminous Flux 0.003 Warm White -0.015 0 25 50 75 100 Neutral White Cool White 25°C Pulsed 125 Case Temperature (°C) Case Temperature (°C) Figure 10: 2000K, 65 CRI Color Shift vs. Case Temperature Figure 9: Typical DC ccx Shift vs. Case Temperature 0.4101 0.000 0 25 50 75 100 0.41 125 0.4099 0.4098 -0.002 Pulsed Center Point Tc=25°C 15°C 25°C 0.4097 ccy ccx Shift -0.004 -0.006 65°C 0.4093 Warm White -0.012 0.4095 0.4094 -0.008 -0.010 45°C 0.4096 Neutral White 85°C 0.4092 Cool White 25°C Pulsed 105°C 0.4091 Case Temperature (°C) 0.409 0.525 0.526 0.527 0.528 0.529 0.53 0.531 0.532 ccx Notes for Figures 7 - 9: 1. Characteristics shown for warm white based on 3000K and 80 CRI. 2. Characteristics shown for neutral white based on 4000K and 80 CRI. 3. Characteristics shown for cool white based on 5000K and 70 CRI. 4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information. 24 Performance Curves Figure 12: 2500K Color Shift vs. Case Temperature1 Figure 11: 1750K Color Shift vs. Case Temperature1 0.3705 0.4145 Pulsed Center Point Tc = 25°C 15°C 0.37 15°C 0.414 25°C 0.4135 25°C 0.413 0.3695 0.369 ccy ccy 45°C 85°C 0.411 105°C 0.5198 0.52 70°C 85°C 0.4115 0.3685 0.368 0.5196 45°C 0.4125 0.412 70°C 0.5202 0.5204 105°C 0.4105 0.468 0.5206 0.47 0.472 0.474 0.369 15°C 0.342 0.34 0.367 0.332 70°C 0.33 0.365 0.364 70°C 0.363 85°C 0.328 Pulsed Center Point Tc=25°C 45°C 45°C 0.334 ccy ccy 25°C 0.366 0.336 0.326 0.368 Pulsed Center Point Tc = 25°C 25°C 0.338 0.478 Figure 14: 3000K, Class A Color Shift vs. Case Temperature1 0.344 15°C 0.476 ccx ccx Figure 13: 5600K Color Shift vs. Case Temperature1,3 Pulsed Center Point Tc = 25°C 85°C 0.362 105°C 0.361 0.324 0.322 0.32 0.322 0.324 0.326 0.328 105°C 0.36 0.416 0.33 0.4165 0.417 ccx Figure 15: 3500K, Class A Color Shift vs. Case Temperature1 ccx 0.4175 0.418 0.4185 Figure 16: 4000K, Class A Color Shift vs. Case Temperature1 0.37 0.3760 15°C 0.368 Pulsed Center Point Tc=25°C 25°C 0.366 15°C 0.3740 25°C 0.3720 45°C 45°C ccy 0.3700 ccy Pulsed Center Point Tc=25°C 0.364 0.3680 70°C 0.362 85°C 0.36 85°C 0.3640 105°C 0.358 0.392 70°C 0.3660 105°C 0.393 0.394 0.395 0.396 0.397 ccx 0.3620 0.373 0.374 0.375 0.376 ccx 0.377 0.378 0.379 Note for Figures 10-16: 1. Measurements made under DC test conditions at the nominal drive current. 2. Typical color shift is shown with a tolerance of ±0.002. 3. Color shift shown for product hot targeted at Tc=85°C 25 Performance Curves Figure 17: Vero 29D Drive Current Derating Curve 4400 Drive Current (mA) 4200 4000 3960 3800 3600 3400 Max Drive Current LM-80 Max Drive Current 3200 0 10 20 30 40 50 60 70 80 90 100 110 Case Temperature (⁰C) Notes for Figure 17: 1. The maximum allowable drive current for the Vero 29D product is dependent on the operating case temperature. Please refer to the Product Feature Map (page 2) for the location of the Tc Point 2. LM-80 Max Drive Current must not be exceeded in order to meet LM-80 lifetime projections. 3. Lumen maintenance (L70) and lifetime predictions are valid for drive current and case temperature conditions used for LM-80 testing as included in the applicable LM-80 test report for these products. Contact your Bridgelux sales representative for LM-80 report. 26 Typical Radiation Pattern Figure 18: Typical Spatial Radiation Pattern Note for Figure 18: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value. Figure 19: Typical Polar Radiation Pattern 27 Typical Color Spectrum Figure 20: Typical Color Spectrum 110% 3000K 100% 4000K 5000K Relative Spectral Power Distribution 90% 6500K 80% 70% 60% 50% 40% 30% 20% 10% 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 20: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. Figure 21: Typical Color Spectrum for Vero 29 with Décor Series 1 17E 20B 0.9 25E 27H Relative Spectral Power Distribution 0.8 30H 56G 0.7 56H 0.6 0.5 0.4 0.3 0.2 0.1 0 400 450 500 550 600 Wavelength (nm) 650 700 750 800 Note for Figure 21: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 28 Mechanical Dimensions Figure 22: Drawing for Vero 29 LED Array Notes for Figure 22: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ± 0.10mm. 4. Mounting holes (4X) are for M3 screws. 5. Bridgelux recommends four tapped holes for mounting screws with 43.0 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 29 Color Binning Information Figure 23: Graph of Warm and Neutral White Test Bins in xy Color Space 0.44 2500K 4SDCM 3 SDCM 4 SDCM 2000K 3SDCM 2700K 0.42 3000K 3500K 0.4 Y 4000K 1750K 4SDCM 0.38 0.36 0.34 0.36 0.39 0.42 0.45 X 0.48 0.51 0.54 Note: Pulsed Test Conditions, Tc = 25°C Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 1750K 2000K 2500K 2700K ANSI Bin (for reference only) - - - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - - - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - - - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.5167, 0.366) (0.5280, 0.4100) (0.4765, 0.4137) (0.4578, 0.4101) 3000K1 (0.4338, 0.403) 3500K1 4000K1 (0.4073, 0.3917) (0.3818, 0.3797) Note for Table 8: 1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information. Figure 24: Graph of Cool White Test Bins in xy Color Space 0.39 4 SDCM 3 SDCM 0.38 0.37 5000K 0.36 5700K Y 0.35 0.34 6500K 0.33 0.32 0.31 0.3 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Bin Code 5000K 5600K1 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5310K - 6020K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5475K - 5830K) (5829K - 5481K) (6270K - 6765K) 73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (5490K - 5820K) (6250K - 6745K) Center Point (x,y) (0.3447, 0.3553) (0.3293, 0.3423) (0.3287, 0.3417) (0.3123, 0.3282) Note for Table 9: 1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C. 30 Packaging and Labeling Figure 25: Drawing for Vero 29 Packaging Tray Notes for Figure 25: 1. Dimensions are in millimeters. 2. Drawings are not to scale. 31 Packaging and Labeling Figure 26: Vero Series Packaging and Labeling Notes for Figure 26: 1. Each tray holds 50 COBs. 2. Each tray is vacuum sealed in an anti-static bag and placed in its own box. 3. Each tray, bag and box is to be labeled as shown above. Figure 27: Gen. 7 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E10K0C 73 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 32 Design Resources Application Notes 3D CAD Models Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. Optical Source Models LM80 Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. Precautions CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN31 for additional information. CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. Disclaimers MINOR PRODUCT CHANGE POLICY STANDARD TEST CONDITIONS The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Unless otherwise stated, array testing is performed at the nominal drive current. 33 About Bridgelux: Bridging Light and Life™ At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com © 2016-2019 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.. Bridgelux Gen 7 Vero 29 Array Series Product Data Sheet DS93 Rev. R (09/2020) 34
BXRC-40G10K0-B-72 价格&库存

很抱歉,暂时无法提供与“BXRC-40G10K0-B-72”相匹配的价格&库存,您可以联系我们找货

免费人工找货