CXM-32-50-90-54-AC30-F4-5

CXM-32-50-90-54-AC30-F4-5

  • 厂商:

    LUMINUS(朗明纳斯)

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
CXM-32-50-90-54-AC30-F4-5 数据手册
CXM-32 Product Datasheet Generation 3 CXM-32 COB Arrays White LED Features: Table of Contents • High lumen output and efficacy typical • Over 17,295 lm, 154 LPW @ 3000K, 80 CRI, Tj = 85ºC Technology Overview. . . . . . 2 • Over 19,675 lm, 176 LPW @ 5000K, 70 CRI, Tj = 85ºC Test Specifications . . . . . . . . . 2 • CCT 2700K, 3000K, 3500K, 4000K, 5000K, 5700K and 6500K Chromaticity Bins. . . . . . . . . . 3 • CRI Ra 80, 90 and 95 min. in all colors (except 5000K, 5700K and 6500K) Product Ordering & Shipping Part Numbers. . . . . . . . . . . . . . 4 Product Typical Flux Range. 5 • CRI Ra 70 in 4000K, 5000K, 5700K and 6500K • R9 up to 85 min. CRI 98 typical in 2700K, 3000K, 3500K and 4000K • 3 SDCM color binning accuracy • Excellent optical emission uniformity and color over angle consistency Product Flux Bins. . . . . . . . . . . 6 • Exceptional long term color stability Operating Characteristics . . 6 • Package thermal conductivity more than twice the industry average Optical and Electrical Characteristics. . . . . . . . . . . . . . . . . . . . . . . 7 • Environmentally friendly: RoHS and REACH compliant • UL reconigized, file # E465703 Spectra. . . . . . . . . . . . . . . . . . . . 8 Mechanical Dimensions. . . . 9 Packaging Information. . . . . 9 Handling Notes. . . . . . . . . . . 10 Applications • Architectural and Specialty • Parking Lot and Area Lighting • Street Lighting • Tunnel Lighting 1 PDS-002858 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CXM-32 Product Datasheet Technology Overview Luminus Chip-on-Board (COB) LED series offers a complete lighting class solution designed for high performance illumination applications. The selection covers a wide lumen range from less than 400lm to over 10,000lm, all major color temperatures and can deliver Reliability Designed from the ground up, the Luminus COB LED is one of the most reliable light sources in the world today. Having passed a rigorous suite of environmental and mechanical stress tests, including mechanical shock, vibration, temperature cycling and humidity. Only then are the devices qualified for use in a wide range of lighting application including some of the most demanding commercial applications. Delivered with fully qualified LM80 test data and TM21 lifetime results that certify lumen maintenance at 35,000 hours or more, Luminus COB LEDs are ready for the toughest challenges. UL Recognized Compliance Luminus COB arrays are tested in accordance with ANSI/UL 8750 to ensure safe operation for their intended applications. REACH & RoHS Compliance All LED products manufactured by Luminus are REACH and RoHS compliant and free of hazardous materials, including lead and mercury. Understanding Luminus COB LED Test Specifications Every Luminus LED is fully tested to ensure it meets the high quality standards customers have come to expect from Luminus’ products. Traceability Chromaticity Bin Range Each Luminus COB LED is marked with a 2D bar code that contains a unique serial number. With this serial number, Luminus has the ability to provide customers with actual test data measurements for a specific LED. In addition, the 2D bar code is linked to manufacturing date codes that enables traceability of production processes and materials. Chromaticity binning delivers color consistency for every order. Standard products are delivered with a 3-step MacAdam ellipse. This ensures color performance matching in the application. For the most demanding application, Luminus is one of only a few companies that can provide a 2-step ellipse bin. These tightly controlled, small distribution bins provide customers predictable, repeatable colors. Testing Temperature Luminus COB products are measured at temperatures typical for the LED operating in the fixture. Each device is tested at 85ºC junction temperature eliminating the need to scale datasheet specifications to real world situations. 2 PDS-002858 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CXM-32 Product Datasheet Chromaticity Bins Chromaticity Bins: 1931 CIE Curve 0.46 0.46 ANSI ANSIC78.377-2008 C78.377-2008 2-step 3-stepEllipse Ellipse 3-step Ellipse 5-step Ellipse 5-step Ellipse 0.44 0.44 2700K 2700K 3000K 3000K 3500K 3500K 0.42 0.42 Black Body 4000K 4000K CIE CIE y y 0.4 0.4 Black Body 5000K 5000K 0.38 0.38 5700K 0.36 0.36 6500K 6500K 0.34 0.34 0.32 0.32 0.3 0.3 0.3 0.3 0.32 0.34 0.32 0.36 0.34 0.36 0.38 0.38 0.4 0.42 0.4 0.44 0.42 CIE x CIE x 0.44 0.46 0.48 0.46 0.5 0.48 0.5 The following tables describe the ANSI bin center points, the orientation angle for the MacAdam ellipse (θ °), and the maximum radii for the ellipses. The ANSI Bin is provided for reference. CCT Center Point Angle 3-step Bin 5-step Bin CIEx CIEy θ (°) a b 2700K 0.4578 0.4101 53.7 0.0081 0.0042 3000K 0.4338 0.403 53.2 0.00834 0.00408 3500K 0.4073 0.3917 54 0.00927 0.00414 4000K 0.3818 0.3797 53.7 0.00939 0.00402 5000K 0.3447 0.3553 59.6 0.00822 5700K 0.3287 0.3417 59.09 6500K 0.3123 0.3282 58.57 *Note: a b 0.00354 0.0137 0.0059 0.00746 0.0032 0.0124 0.0053 0.00669 0.00285 0.01115 0.00475 Luminus maintains a +/- 0.005 tolerance on chromaticity (CIEx and CIEy) measurements. 3 PDS-002858 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CXM-32 Product Datasheet Part Number Nomenclature All CXM-32 products are packaged and labeled with part numbers as outlined in the table on page 5. Luminus may include any smaller chromaticity bin that is contained in the larger bin as part of the ordered part. When shipped, each package will contain only a single flux and chromaticity bin. The part number designation is as follows: CXM 32 NN Product Family Light Emitting Surface Diameter CXM: Chip on Board 32: LES Diameter (mm) XX 54 QQPP FG W Color Temperature Color Rendering Index (CRI) Voltage (typical) Package Configurator Flux Bin Chromaticity Bin Color See Note 1 Below CRI See Table Below Volts AC00 (Basic package) Lumens See page 3 for bins Note 1: NN nomenclature corresponds to the following: 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K 50 = 5000K 57 = 5700K 65 = 6500K Color Temperature, CRI and R9 Values Color Temperatures XX Value CRI R9 4000K, 5000K, 5700K, 6500K 70 >70 - 2700K, 3000K, 3500K, 4000K, 5000K, 5700K, 6500K 80 >80 >0 2700K, 3000K, 3500K, 4000K, 5000K 90 >90 >50 95 >95 2700K, 3000K 3500K, 4000K Note: >85 >75 Luminus part numbers may be accompanied by prefixes or suffixes. The most common is the “Rev01” suffix indicating a part is fully released and carries a full warranty. These additional characters may appear on shipping labels, packing slips and invoices. In all cases the basic part number described above will always be included. 4 PDS-002858 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CXM-32 Product Datasheet CXM-32 Part Numbers The following tables describe products with typical flux and minimum flux measured at 2,200mA and specified at Tj = 85ºC. The values at 25ºC are calculated and shown for reference only. Luminus may choose to ship a smaller chromaticity bin in an order for a larger. Output Flux (lm) CCT 3000K 3500K 4000K 3-step MacAdam Ellipse 15,225 18,005 80 CXM-32-27-80-54-AC30-F4-3 13,490 12,545 14,840 90 CXM-32-27-90-54-AC30-F4-3 12,905 12,000 14,195 95 CXM-32-27-95-54-AC30-F4-3 17,295 16,085 19,025 80 CXM-32-30-80-54-AC30-F4-3 14,550 13,530 16,005 90 CXM-32-30-90-54-AC30-F4-3 13,585 12,635 14,945 95 CXM-32-30-95-54-AC30-F4-3 17,810 16,565 19,590 80 CXM-32-35-80-54-AC30-F4-3 14,840 13,800 16,320 90 CXM-32-35-90-54-AC30-F4-3 14,190 13,200 15,610 95 CXM-32-35-95-54-AC30-F4-3 19,350 18,000 21,285 70 CXM-32-40-70-54-AC30-F4-3 18,045 16,780 19,850 80 CXM-32-40-80-54-AC30-F4-3 15,655 14,560 17,220 90 CXM-32-40-90-54-AC30-F4-3 14,530 13,515 15,675 95 CXM-32-40-95-54-AC30-F4-3 Reference Color Rendering Index Part Number (25ºC) Typ. Min.. (85ºC) (calculated) 19,675 18,300 18,170 Typ. (85ºC) 6500K CRI (min.) Typ. 16,370 CCT 5700K Ordering Part Number (calculated) Output Flux (lm) 5000K Color Rendering Index Min. (85ºC) Typ. (85ºC) 2700K Reference CRI (min.) 5-step MacAdam Ellipse 3-step MacAdam Ellipse 21,645 70 CXM-32-50-70-54-AC30-F4-5 CXM-32-50-70-54-AC30-F4-3 16,895 19,985 80 CXM-32-50-80-54-AC30-F4-5 CXM-32-50-80-54-AC30-F4-3 15,730 14,630 17,305 90 CXM-32-50-90-54-AC30-F4-5 CXM-32-50-90-54-AC30-F4-3 19,690 18,310 21,660 70 CXM-32-57-70-54-AC30-F4-5 CXM-32-57-70-54-AC30-F4-3 18,140 16,865 19,950 80 CXM-32-57-80-54-AC30-F4-5 CXM-32-57-80-54-AC30-F4-3 19,700 18,320 21,670 70 CXM-32-65-70-54-AC30-F4-5 CXM-32-65-70-54-AC30-F4-3 18,100 16,835 19,910 80 CXM-32-65-80-54-AC30-F4-5 CXM-32-65-80-54-AC30-F4-3 (25ºC) *Note: Luminus maintains a +/- 6% tolerance on flux measurements. Luminus maintains a +/- 2% tolerance on CRI measurements. 5 PDS-002858 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CXM-32 Product Datasheet CXM-32 Operating Characteristics1 Optical and Electrical Characteristics Parameter Forward Current Symbol 2 If Forward Voltage3 Vf Minimum 48 Power Operating Case Temperature4 Typical Maximum Unit 2,200 4,400 mA 51 56 V 112 240 W 105 ºC Tc Light Emitting Surface Diameter LES 32 mm Thermal Resistance (junction-to-case) Qjc 0.11 ºC/W Junction Temperature Tj Viewing Angle 140 120 ºC Degree Note 1: Ratings are based on operation at a constant junction temperature of Tj = 85ºC. Note 2: To prevent damage refer to operating conditions and derating curves for appropriate maximum operating conditions Note 3: Voltage is rated at typical forward current. For voltage at higher drive current, refer to performance graphs. Note 4: CXM-32 COB LEDs are designed for operation up to an absolute maximum forward drive current as specified above. Refer to the current vs. case temperature derating curves for further information. Note 5: Caution must be taken not to stare at the light emitted from these LEDs. Under special circumstances, the high intensity could damage the eye. 6 PDS-002858 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CXM-32 Product Datasheet CXM-32 Optical & Electrical Characteristics Relative Output Flux vs. Forward Current @ 85ºC Forward Current vs. Forward Voltage @ 85ºC 200% 4400 180% 3900 160% 3400 Forward Current (mA) Relative Luminous Flux 140% 120% 100% 80% 60% 2900 2400 1900 1400 40% 900 20% 0% 400 900 1400 1900 2400 2900 Forward Current (mA) 3400 3900 400 4400 Relative Output Flux vs. Junction Temperature 47 48 49 50 51 52 Forward Voltage (V) 53 54 55 Change in Voltage vs. Junction Temperature 120% 60 Forward Voltage (V) Relative Luminous Flux 58 100% 80% 56 54 52 60% 50 40% 5 15 25 35 45 55 65 75 85 95 105 48 5 15 25 35 55 65 75 85 95 105 Change in CIEy vs. Junction Temp. (3000K, 80CRI) 0.02 0.02 0.01 0.01 Δ CIEy Δ CIEx Change in CIEx vs. Junction Temp. (3000K, 80CRI) 0 0 -0.01 -0.01 -0.02 45 Junction Temperature (ºC) Junction Temperature (ºC) 5 15 25 35 45 55 65 75 Junction Temperature (ºC) 7 PDS-002858 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved 85 95 105 -0.02 5 15 25 35 45 55 65 Junction Temperature (ºC) 75 85 95 105 CXM-32 Product Datasheet CXM-32 Optical & Electrical Characteristics Typical Spectrum 120.00% 100.00% Relative Intensity 80.00% Warm White 60.00% Neutral White Cool White 40.00% 3000K-90CRI 3000K-97CRI 20.00% 0.00% 400 450 500 -20.00% 550 600 650 700 750 800 Wavelength (nm) Typical Polar Radiation Pattern Typical Angular Radiation Pattern 120% 100% Relative Intensity (%) 80% 60% 40% 20% 0% -80 -60 -40 -20 0 20 Anglular Displacement (Degrees) 8 PDS-002858 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved 40 60 80 CXM-32 Product Datasheet Mechanical Dimensions Shipping Container 60 pcs per box Each bag is boxed for easier storage/ stacking 20 pcs per tray 3 trays are stacked together with separate cover Trays are sealed in an anti-static bag Label Luminus Label Model: XXXXXX-XX-XX (Manufacturer Part Number & Bin Kits) XXX-XX-XX-XX-XX-XXXX-XX-X XXXXXXXXXXXXXX Bar code 9 PDS-002858 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved Rev XX Bar code Bar code (Box ID) (Customer Part Number) Qty: XX Bar code RoHS Compliant Luminus Devices Inc CXM-32 Product Datasheet (Part #) Product Handling Notes for Luminus COBs Luminus products are designed for robust performance in general lighting application. However, care must be taken when handling and assembling the LEDs into their fixtures. To avoid damaging Luminus COBs please follow these guidelines. The following is an overview of the application notes detailing some of the practices to follow when working with these devices. More detailed information is available on the Luminus web site at www.luminus.com. General Handling Electrical Contact Devices are made to be lifted or carried with tweezers on two adjacent corners opposite the contact pads. At no time should the devices be handled by or should anything come in contact with the light emitting surface (LES) area. This area includes the yellow colored circular area and the ring surrounding it. There are electrical connections under the LES which if damaged will cause the device to fail. Luminus COBs are designed with contact pads on their top surface. These pads are clearly marked with + and – polarity. Wires can be soldered to the contact pads for electrical connections or other solderless connector products are available. In addition, the ring frame itself should not be used for moving, lifting or carrying the device. Also do not attach any optics or mechanical holders to the ring as it is not capable to handle the mechanical stress. If wires are being soldered to the COB product, we recommend attaching these wires prior to mounting the devices to a heat sink. Please contact Luminus for specific recommendations on how to solder wires if not familiar with the standard practice. Luminus can also offer design recommendations for jigs to allow easily soldering multiple products in rapid succession. Static Electricity Chemical Compatibility Luminus COBs are electronic devices which can be damaged by electrostatic discharge (ESD). Please use appropriate measures to assure the devices do not experience ESD during their handling and or storage. ESD protection guidelines should be used at all times when working with Luminus COBs. The resin material used to form the LES can getter hydrocarbons from the surrounding environment. As a results, certain chemical compounds are not recommended for use with the Luminus products. Use of these compounds can cause damage to the light output of the device and may permanently damage the device. Please refer to www.luminus.com for a list of the compounds not recommended for use with the Luminus COB products. Storage: Luminus products are delivered in ESD shielded bags and should be stored in these bags until used. Assembly: Individuals handling Luminus COBs during assembly should be trained in ESD protection practices. Assemblers should maintain constant conductive contact with a path to ground by means of a wrist strap, ankle straps, mat or other ESD protection system. Transporting: When transporting the devices from one assembly area to another, ESD shielded carts and carriers should be used. 10 PDS-002858 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved Thermal Interface Material (TIM) Proper thermal management is critical for successful operation of any LED system. Excess operating temperature can reduce the light output of the device. And excessive heating can cause permanent damage to the device. Proper TIM material is a crucial component for effective heat transfer away from the LED during normal operation. Please refer to www.luminus.com for specific recommendations for TIM solutions.
CXM-32-50-90-54-AC30-F4-5 价格&库存

很抱歉,暂时无法提供与“CXM-32-50-90-54-AC30-F4-5”相匹配的价格&库存,您可以联系我们找货

免费人工找货