0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DF-G1-NS-2M

DF-G1-NS-2M

  • 厂商:

    BANNER

  • 封装:

    -

  • 描述:

    FIBER AMPLIFIER 1 NPN OUT

  • 数据手册
  • 价格&库存
DF-G1-NS-2M 数据手册
DF-G1 Expert™ Dual Display Fiber Amplifier Instruction Manual Original Instructions 161999 Rev. G 22 March 2019 © Banner Engineering Corp. All rights reserved 161999 DF-G1 Expert™ Dual Display Fiber Amplifier Contents 1 Product Description ........................................................................................................................................................3 1.1 Models ............................................................................................................................................................................................ 3 1.2 Overview .......................................................................................................................................................................................... 4 1.3 Top Panel Interface ..........................................................................................................................................................................4 2 Installation Instructions ...................................................................................................................................................5 2.1 Mounting Instructions ..................................................................................................................................................................... 5 2.2 Installing the Fibers .........................................................................................................................................................................5 2.3 Fiber Adapters ................................................................................................................................................................................ 6 2.4 Wiring Diagrams ..............................................................................................................................................................................6 3 Operating Instructions .................................................................................................................................................... 8 3.1 Run Mode ....................................................................................................................................................................................... 8 3.2 Program Mode ................................................................................................................................................................................ 8 3.2.1 TEACH Selection ...................................................................................................................................................................10 3.2.2 Response Speed ................................................................................................................................................................... 10 3.2.3 Offset Percent ....................................................................................................................................................................... 10 3.2.4 Auto Thresholds .................................................................................................................................................................... 10 3.2.5 Delays/Timers ........................................................................................................................................................................11 3.2.6 Display Readout .................................................................................................................................................................... 11 3.2.7 Gain Selection ....................................................................................................................................................................... 11 3.2.8 Factory Defaults .................................................................................................................................................................... 11 3.3 Remote Input (not available on IO-Link models) ............................................................................................................................11 3.4 Adjust Mode ..................................................................................................................................................................................12 3.4.1 Two-Point TEACH .................................................................................................................................................................. 13 3.4.2 Dynamic TEACH .....................................................................................................................................................................14 3.4.3 Window SET ........................................................................................................................................................................... 16 3.4.4 Light SET ................................................................................................................................................................................ 17 3.4.5 Dark SET ............................................................................................................................................................................... 19 3.4.6 Calibration SET .......................................................................................................................................................................21 3.4.7 Troubleshooting .................................................................................................................................................................... 22 4 IO-Link Interface ............................................................................................................................................................ 23 ................................................................................................................................................................ 24 5 Specifications 5.1 Excess Gain Curves ......................................................................................................................................................................25 5.2 Beam Patterns ............................................................................................................................................................................... 28 5.3 Dimensions .................................................................................................................................................................................... 30 6 Accessories .................................................................................................................................................................. 31 6.1 Quick-Disconnect Cordsets ..........................................................................................................................................................31 7 Banner Engineering Corp. Limited Warranty ................................................................................................................ 33 DF-G1 Expert™ Dual Display Fiber Amplifier 1 Product Description Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies • • • • • • • • • • • Easy to read dual digital displays show both signal level and threshold simultaneously Lever action fiber clamp provides stable, reliable, and trouble-free fiber clamping Simple user interface ensures easy sensor set-up and programming via displays and switches/buttons, remote input teach wire, or IO-Link Expert TEACH and SET methods ensure optimal gain and threshold for all applications, especially low contrast applications User has full control over all operating parameters: threshold, Light Operate or Dark Operate, output timing functions, gain level, and response speed Thermally stable electronics minimize warm-up drift and the effect of sideby-side mounting of multiple fiber amplifiers ECO (economy) display mode reduces amplifier power consumption by 25% Cross talk avoidance algorithm allows two sensors to operate in close proximity for many applications Response speeds of: 200 µs (High Speed), 500 µs (Standard), 2 ms (Long Range), and 5 ms (Extra Long Range) allow the operator to optimize for fast or long distance applications Sleek 10 mm wide housing mounts to 35 mm DIN rail Visible red LED sensing beam WARNING: • Do not use this device for personnel protection • Using this device for personnel protection could result in serious injury or death. • This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A device failure or malfunction can cause either an energized (on) or de-energized (off) output condition. 1.1 Models Connector1 Model Outputs DF-G1-NS-2M Single NPN DF-G1-PS-2M Single PNP DF-G1-KS-2M Dual outputs, 1 push-pull IO-Link and 1 PNP (complementary outputs) DF-G1-NS-Q5 Single NPN DF-G1-PS-Q5 Single PNP DF-G1-KS-Q5 Dual outputs, 1 push-pull IO-Link and 1 PNP (complementary outputs) DF-G1-NS-Q7 Single NPN DF-G1-PS-Q7 Single PNP DF-G1-KS-Q7 Dual outputs, 1 push-pull IO-Link and 1 PNP (complementary outputs) 1 2 m (6.5 ft) cable, 4-wire 150 mm (6 in) PVC pigtail, M12 Euro QD connector, 4-pin Integral M8 Pico QD connector, 4-pin Connector options: • A model with a QD connector requires a mating cordset (see Quick-Disconnect Cordsets on page 31). • For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G1-NS-9M). • For 150 mm (6 in) PVC pigtail, M8 Pico QD connector, 4-pin change the suffix 2M to Q3 in the 2 m model number (example, DF-G1-NSQ3). www.bannerengineering.com - Tel: + 1 888 373 6767 3 DF-G1 Expert™ Dual Display Fiber Amplifier 1.2 Overview The DF-G1 is an easy-to-use, DIN-rail-mountable fiber optic device. It provides high-performance sensing in low-contrast applications. The sensor’s compact housing has dual digital displays (Red/Green) and a bright output LED for easy programming and status monitoring during operation. The sensor features a single discrete output, either NPN or PNP, by model. The DF-G1 features increased temperature compensation compared with previous fiber optic sensors. An accessory clamp is available to secure a bank of connected sensors together on a DIN rail (see Accessories on page 31). Figure 1. DF-G1 Model Features 1 Output LED 2 LO/DO Switch 3 RUN/PRG/ADJ Mode Switch 4 Lever Action Fiber Clamp 5 Red Signal Level 6 Green Threshold 7 +/SET/- Rocker Button 1.3 Top Panel Interface Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ mode switch, LO/DO switch, +/SET/- rocker button, dual red/green digital displays, and output LED. RUN/PRG/ADJ Mode Switch The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode. RUN mode allows the sensor to operate normally and prevents unintentional programming changes via the +/SET/button. PRG mode allows the sensor to be programmed through the display driven programming menu (see Program Mode on page 8 ). ADJ mode allows the user to perform Expert TEACH/SET methods and Manual Adjust (see Adjust Mode on page 12 ). LO/DO Switch The LO/DO switch is used to select Light Operate or Dark Operate mode. In Light Operate mode, the output is ON when the sensing condition is above the threshold (for Window SET, the output is ON when the sensing condition is inside the window). In Dark Operate mode, the output is ON when the sensing condition is below the threshold (for Window SET, the output is ON when the sensing condition is outside the window). +/SET/- Rocker Button The +/SET/- rocker button is a 3-way button. The +/- positions are engaged by rocking the button left/right. The SET position is engaged by clicking down the button while the rocker is in the middle position. All three button positions are used during PRG mode to navigate the display driven programming menu. During ADJ mode, SET is used to perform TEACH/SET methods and +/- are used to manually adjust the threshold(s). The rocker button is disabled during RUN mode, except when using Window SET, see Window SET on page 16. Red/Green Digital Displays During RUN and ADJ mode, the Red display shows the signal level and the Green display shows the threshold. During PRG mode, both displays are used to navigate the display driven programming menu. Output LED The output LED provides a visible indication when the output is activated. 4 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G1 Expert™ Dual Display Fiber Amplifier 2 Installation Instructions 2.1 Mounting Instructions Mount on a DIN Rail 1. Hook the DIN rail clip on the bottom of the DF-G1 over the edge of the DIN rail (1). 2. Push the DF-G1 up on the DIN rail (1). 3. Pivot the DF-G1 onto the DIN rail, pressing until it snaps into place (2). Mount to the Accessory Bracket (SA-DIN-BRACKET) 1. Position the DF-G1 in the SA-DIN-BRACKET. 2. Insert the supplied M3 screws. 3. Tighten the screws. Remove from a DIN rail 1. Push the DF-G1 up on the DIN rail (1). 2. Pivot the DF-G1 away from the DIN rail and remove it (2). 2.2 Installing the Fibers Follow these steps to install glass or plastic fibers. 1. 2. 3. 4. 5. Open the dust cover. Move the fiber clamp forward to unlock it. Insert the fiber(s) into the fiber port(s) until they stop. Move the fiber clamp backward to lock the fiber(s). Close the dust cover. www.bannerengineering.com - Tel: + 1 888 373 6767 Move forward to release the fibers Fiber Clamp Fiber Receiver Port Fiber Emitter Port 5 DF-G1 Expert™ Dual Display Fiber Amplifier 2.3 Fiber Adapters Note: If a thin fiber with less than 2.2 mm outer diameter is used, install the fiber adapter provided with the fiber assembly to ensure a reliable fit in the fiber holder. Align the fibers to the end of the adaptors. Banner includes the adapters with all fiber assemblies. TO FIBERS TO SENSOR Fiber Outer Diameter (mm) Adapter Color Ø 1.0 Black Ø 1.3 Red Ø 2.2 No adapter needed When connecting coaxial-type fiber assemblies to the amplifier, install the single-core (center) fiber to the Transmitter port, and the multi-core (outer) fiber to the Receiver port. This will result in the most reliable detection. RECEIVER Multi-core fiber Single-core fiber TRANSMITTER 2.4 Wiring Diagrams NPN Models PNP Models 1 1 10-30V dc 3 4 2 6 Key 4 Load Remote Programming (N.O.) 10-30V dc 3 2 Load Remote Programming (N.O.) www.bannerengineering.com - Tel: + 1 888 373 6767 1 = Brown 2 = White 3 = Blue 4 = Black DF-G1 Expert™ Dual Display Fiber Amplifier Open lead wires must be connected to a terminal block. PUSH-PULL IO-Link Models Load 18–30 V dc Load www.bannerengineering.com - Tel: + 1 888 373 6767 7 DF-G1 Expert™ Dual Display Fiber Amplifier 3 Operating Instructions 3.1 Run Mode Run mode allows the sensor to operate normally and prevents unintentional programming changes. The +/SET/- rocker button is disabled during RUN mode, except when using Window SET. 3.2 Program Mode Program (PRG) mode allows the following settings to be programmed in the DF-G1 (refer to Program Mode Flowchart and and Remote Input Flowchart for programming). 8 www.bannerengineering.com - Tel: + 1 888 373 6767 + SET - On dLY On 1Sho Click SET to enter choice list FctY dEF Click SET to enter choice list GAin SEL Click SET to enter choice list no DISPLAY LOOP Auto GAin DISPLAY LOOP diSP 1234 1234 Gn 1 Fixed Gain Set Eco 1234 1234 Gn 2 diSP 123P Eco 123P 1234 Gn 8 yES DISPLAY LOOP diSP rEAd To scroll through menu lists: Press “+” or “-” To enter a choice list or to select and save: Click SET To exit a choice list without saving: Press and hold SET for 2 seconds OFF 1Sho 0 ms Click SET to enter choice list 0 ms (+) or (-) to set value Click SET to enter choice list 0 ms (+) or (-) to set value 9999 ms Click SET to enter choice list 0 ms (+) or (-) to set value 9999 ms Click SET to enter choice list OFF dLY rocker button Auto thr Click SET to enter choice list (+) or (-) to set value 9999 ms diSP 1234 Click SET to enter choice list DISPLAY LOOP oFF On 9999 ms (display flips 180˚) Eco 1234 Mode Switch to “PRG” Click SET to enter choice list DISPLAY LOOP min OFSt OFSt Pct DISPLAY LOOP 200 uS 10 Pct tcH SEL 2Pt tcH 500 uS 999 Pct on display represents a “m” Click SET to select and save a choice in any list diSP 123P Press and hold SET to exit choice list without saving rESP SPd PROGRAM MODE Menu List dYn tcH 2000 uS Click SET to enter choice list wind SEt 5000 uS (+) or (-) to set value Lt SEt dr SEt CAL SEt Return to Menu List on display represents a “w” Eco 123P DF-G1 Expert™ Dual Display Fiber Amplifier Figure 2. 9 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G1 Expert™ Dual Display Fiber Amplifier 3.2.1 TEACH Selection The DF-G1 can be programmed for one of the following TEACH/SET methods: • Two-Point TEACH • Dynamic TEACH • Window SET • Light SET • Dark SET • Calibration SET Note: A TEACH Selection must be selected by programming before TEACH/SET methods can be used. 3.2.2 Response Speed The DF-G1 can be programmed for one of the following Response Speeds: Response Speed Display Range Crosstalk Avoidance Algorithm 200 µs (High Speed) 0 - 4000 Disabled 500 µs (Standard) 0 - 4000 Enabled 2000 µs (Long Range) 0 - 9999 Enabled 5000 µs (Extra Long Range) 0 - 9999 Enabled 3.2.3 Offset Percent The Offset Percent is used during the Window, Light, or Dark SET methods. The threshold(s) are positioned a programmable % offset from the taught condition. The allowable range depends upon the Response Speed Mode, as shown below: Response Speed MIN % MAX % 200 µs (High Speed) 10 999 500 µs (Standard) 10 999 2000 µs (Long Range) 2 999 5000 µs (Extra Long Range) 2 999 The offset percent can also be programmed to Minimum Offset. This allows the DF-G1 to set the threshold(s) as close as possible to the presented condition, but still provide for reliable sensing. Note: Offset Percent MUST be programmed to Minimum Offset for Dark SET to accept conditions of no signal (0 counts). 3.2.4 Auto Thresholds Auto Thresholds can be programmed to be ON/OFF. The Auto Thresholds algorithm continuously tracks slow changes in the taught condition(s), and optimizes the threshold(s) to provide for reliable sensing. For Two-Point and Dynamic TEACH, the algorithm optimizes the threshold to be centered between the light and dark conditions. For Window, Light, and Dark SET, the algorithm optimizes the threshold(s) to maintain the programmed Offset Percent from the taught condition. • After programming Auto Thresholds to ON, it is highly recommended to re-perform the TEACH/SET method • Manual Adjustments are disabled when Auto Thresholds are ON • Auto Thresholds are automatically disabled in Calibration SET (see Calibration SET on page 21) • Severe contamination/changes in the taught condition can prevent the Auto Thresholds algorithm from optimizing the threshold(s). If this occurs, the DF-G1 enters a Threshold Alert or Threshold Error state. See Troubleshooting on page 22 for more explanation. 10 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G1 Expert™ Dual Display Fiber Amplifier 3.2.5 Delays/Timers ON/OFF Delays and ON/OFF One-Shot timers can be programmed between 1 9999 ms (a value of 0 disables the delay/ timer). Figure 3 on page 11 defines how the delays/timers affect the output behavior. Some combinations of delays/timers are not allowed. The DF-G1 programming menu automatically disables invalid combinations of delays/timers. The following table shows the allowable combinations of delays/timers: ON Output OFF OFF Delay OFF 1-Shot D D D D ON Delay D D ON 1-Shot D D (D = 1 - 9999 ms) Time Figure 3. DF-G1 Delays/Timers OFF Delay OFF One-Shot Timer ON Delay ON One-Shot Timer - OK OK N/A OFF One-Shot Timer OK - N/A N/A ON Delay OK N/A - OK ON One-Shot Timer N/A N/A OK - OFF Delay 3.2.6 Display Readout The readout of the digital displays can be programmed for the following options: • Signal/Threshold readout - Numeric (1234) or % (123P) • ECO mode - Enabled or Disabled (ECO mode dims the displays to reduce current consumption) • Display Orientation - Normal ( ) or Flipped ( ) 3.2.7 Gain Selection The DF-G1 can operate in Auto Gain mode or the Gain can be fixed to be in Gain 1..8. In Auto Gain, the DF-G1 optimizes the gain during a TEACH/SET method for the presented condition(s). While viewing the fixed gains in the Gain Selection choice list, the DF-G1 will automatically switch to the selected gain and display the measured signal on the Red display. This allows for easy and quick evaluation of the fixed gain mode. 3.2.8 Factory Defaults The Factory Defaults menu allows the DF-G1 to be easily restored back to original factory default settings (see Factory Default Settings in Specifications). 3.3 Remote Input (not available on IO-Link models) The remote input may be used to perform TEACH/SET methods and to program the sensor remotely. Connect the white input wire of the sensor to ground (0 V dc), with a remote switch connected between them. Pulse the remote input according to the diagram shown in Figure 4 on page 12. Follow the instructions in the TEACH/SET sections in Adjust Mode on page 12 to perform a TEACH/SET method. The sensor exits TEACH and remote programming modes after a 60 second timeout. Users may exit TEACH and remote programming modes by setting the remote input low for more than 2 seconds. In either case, the sensor returns to Run mode without saving any new settings. www.bannerengineering.com - Tel: + 1 888 373 6767 11 DF-G1 Expert™ Dual Display Fiber Amplifier Figure 4. Remote Input Flowchart 3.4 Adjust Mode Sliding the RUN/PRG/ADJ mode switch to the ADJ position allows the user to perform Expert TEACH/SET methods and Manual Adjustment of the threshold(s). 12 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G1 Expert™ Dual Display Fiber Amplifier 3.4.1 Two-Point TEACH • • Establishes a single switching threshold Threshold can be adjusted by using the "+" and "-" rocker button (Manual Adjust) Two-Point TEACH is used when two conditions can be presented statically to the sensor. The sensor locates a single sensing threshold (the switch point) midway between the two taught conditions, with the Output ON condition on one side, and the Output OFF condition on the other. Darkest Taught Condition Lightest Taught Condition Sensor positions threshold midway between taught conditions Output OFF Darkest (no signal) Output ON Position adjusted by Manual Adjust Most Light (saturated signal) Figure 5. Two-Point TEACH (Light Operate shown) The Output ON and OFF conditions can be reversed by using the LO/DO (Light Operate/ Dark Operate) switch. Two-Point TEACH and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember: Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Two-Point TEACH: Note: TEACH Selection must be programmed to 2Pt tcH. 1. Enter Adjust mode. Method Action Result SET Button 2 Set the Mode switch to ADJ. Display: Red - Signal Level; Green Threshold Remote Input 3 No action is required; sensor is ready for the Two-Point TEACH method 2. Teach the first condition. Method Action Result SET Button a. Present the first condition. Display: Flashes "2Pt tch" then holds on "1234 2nd" b. Click the SET rocker button. Remote Input a. Present the first condition. T b. Single-pulse the remote input. 2 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 3 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds www.bannerengineering.com - Tel: + 1 888 373 6767 13 DF-G1 Expert™ Dual Display Fiber Amplifier 3. Teach the second condition. Method Action Result SET Button a. Present the second condition. TEACH Accepted b. Click the SET rocker button. Displays alternate "PASS" and % Minimum Difference4; Sensor returns to Adjust mode Remote Input a. Present the second condition. T b. Single-pulse the remote input. TEACH Not Accepted Displays alternate "FAIL" and % Minimum Difference4; Sensor returns to Adjust mode 4. Return to Run mode. Method Action Result SET Button Move the Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action is required; sensor returns to RUN mode automatically 3.4.2 Dynamic TEACH • • • Teaches on-the-fly Establishes a single switching threshold Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust) Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actual sensing conditions, taking multiple samples of the light and dark conditions and automatically setting the threshold at the optimum level. Darkest Taught Condition Lightest Taught Condition Sensor positions threshold midway between taught conditions Output OFF Darkest (no signal) Output ON Position adjusted by Manual Adjust Most Light (saturated signal) Figure 6. Dynamic TEACH (Light Operate shown) The output ON and OFF conditions can be reversed using the LO/DO switch. Dynamic TEACH and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation 4 See Troubleshooting on page 22 for more explanation of the % Minimum Difference displayed after the Two-Point TEACH method. 14 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G1 Expert™ Dual Display Fiber Amplifier Remember: Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform Dynamic TEACH: Note: TEACH Selection must be programmed to dYn tcH. 1. Enter Adjust Mode. Method Action Result SET Button 5 Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold Remote Input 6 No action required; sensor is ready for Dynamic TEACH method 2. Enter Dynamic TEACH. Method Action Result SET Button Click the SET rocker button Display: Flashes "dYn tch" then holds on "1234 dYn" Remote Input Single-pulse remote input T 3. Present ON and OFF Conditions. Method Action Result SET Button Present ON and OFF conditions Display: Red - Signal Level; Green Threshold Remote Input Present ON and OFF conditions 4. Exit Dynamic TEACH. Method Action Result SET Button Click the SET rocker button TEACH Accepted Remote Input Single-pulse remote input Displays alternate "PASS" with % Minimum Difference7, Sensor returns to Adjust mode T TEACH Not Accepted Displays alternate "FAIL" with % Minimum Difference7, Sensor returns to Adjust mode 5. Return to RUN Mode. 5 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 6 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds 7 See Troubleshooting on page 22 for more explanation of the % Minimum Difference displayed after the Dynamic TEACH method. www.bannerengineering.com - Tel: + 1 888 373 6767 15 DF-G1 Expert™ Dual Display Fiber Amplifier Method Action Result SET Button Move Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action required; sensor returns to RUN mode automatically 3.4.3 Window SET • • • • • Sets window thresholds that extend a programmable % offset above and below the presented condition All other conditions (lighter or darker) cause the output to change state Sensing window center can be adjusted using "+" and "-" rocker button (Manual Adjust) Recommended for applications where a product may not always appear in the same place, or when other signals may appear See Program Mode for programming the Offset Percent setting A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and below the presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside the window, and the Output OFF conditions outside the window. Sensing window center adjusted by Manual Adjust Output OFF Darkest (no signal) Output ON Sensor positions window thresholds a programmable % offset from the presented condition Output OFF Condition Presented Most Light (saturated signal) Figure 7. Window SET (Light Operate shown) Output ON and OFF conditions can be reversed using the LO/DO switch. Window SET and Manual Adjust Moves sensing window center value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the sensing window center value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember: Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Window SET: Note: TEACH Selection must be programmed to wind SEt. 1. Enter Adjust Mode 16 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G1 Expert™ Dual Display Fiber Amplifier Method Action Result SET Button 8 Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold Remote Input 9 No action required; sensor is ready for Window SET method 2. SET Sensing Condition Method Action Result SET Button • • Present sensing condition Click the SET rocker button Remote Input • • Present sensing condition Single-pulse the remote input Threshold Condition Accepted Displays read "wInd SEt" then alternate "PASS" with % Offset10; Sensor returns to Adjust mode T Threshold Condition Not Accepted Displays read "wInd SEt" then alternate "FAIL" with minimum % Offset10 for sensing condition; Sensor returns to Adjust mode 3. Return to RUN Mode Method Action Result SET Button Move Mode switch to Run Remote Input No action required; sensor returns to Run mode automatically Display: Red - Signal Level; Green Window Center (see Figure 8 on page 17 for instructions on how to display upper and lower thresholds) Window SET (during RUN mode) Upon sensor power-up, Window Center is displayed Upper Threshold Displayed Window Center Displayed Lower Threshold Displayed Figure 8. Upper and Lower Thresholds 3.4.4 Light SET • • • Sets a threshold a programmable % offset below the presented condition Changes output state on any condition darker than the threshold condition Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust) 8 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 9 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds 10 See Troubleshooting on page 22 for more explanation of the % Offset displayed after the Window SET method www.bannerengineering.com - Tel: + 1 888 373 6767 17 DF-G1 Expert™ Dual Display Fiber Amplifier • • Recommended for applications where only one condition is known, for example a stable light background with varying darker targets See Program Mode for programming the Offset Percent setting A single sensing condition is presented, and the sensor positions a threshold a programmable % offset below the presented condition. When a condition darker than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting. Threshold position adjusted by Manual Adjust Sensor positions threshold a programmable % offset below the presented condition Output OFF Darkest (no signal) Output ON Condition Presented Most Light (saturated signal) Figure 9. Light SET (Light Operate shown) Light SET and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember: Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Light SET: Note: TEACH Selection must be programmed to Lt SEt. 1. Enter Adjust Mode Method Action Result SET Button 11 Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold Remote Input 12 No action is required; sensor is ready for Light SET method 2. SET Sensing Condition 11 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 12 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds 18 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G1 Expert™ Dual Display Fiber Amplifier Method Action Result SET Button • • Present sensing condition Click the SET rocker button Remote Input • • Present sensing condition Single-pulse the remote input Threshold Condition Accepted Displays read "Lt SEt" then alternate "PASS" with % Offset13; Sensor returns to Adjust mode T Threshold Condition Not Accepted Displays read "Lt SEt" then alternate "FAIL" with minimum % Offset13 for sensing condition; Sensor returns to Adjust mode 3. Return to RUN Mode Method Action Result SET Button Move Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action required; sensor returns to RUN mode automatically 3.4.5 Dark SET • • • • • Sets a threshold a programmable % offset above the presented condition Any condition lighter than the threshold condition causes the output to change state Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust) Recommended for applications where only one condition is known, for example a stable dark background with varying lighter targets See Program Mode for programming the Offset Percent setting Note: Offset Percent MUST be programmed to Minimum Offset to accept conditions of no signal (0 counts). A single sensing condition is presented, and the sensor positions a threshold a programmable % offset above the presented condition. When a condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting. Threshold position adjusted by Manual Adjust Sensor positions threshold a programmable % offset above the presented condition Output OFF Darkest (no signal) Condition Presented Output ON Most Light (saturated signal) Figure 10. Dark SET (Light Operate shown) 13 See Troubleshooting on page 22 for more explanation of the % Offset displayed after the Light SET method www.bannerengineering.com - Tel: + 1 888 373 6767 19 DF-G1 Expert™ Dual Display Fiber Amplifier Dark SET and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember: Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Dark SET: Note: TEACH Selection must be programmed to dr SEt. 1. Enter Adjust Mode. Method Action Result SET Button 14 Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold Remote Input 15 No action required; sensor is ready for Dark SET method 2. SET Sensing Condition. Method Action Result SET Button • • Present sensing condition Click the SET rocker button Remote Input • • Present sensing condition Single-pulse the remote input Threshold Condition Accepted Displays read "dr SEt" then alternate "PASS" with % Offset16; Sensor returns to Adjust mode T Threshold Condition Not Accepted Displays read "dr SEt" then alternate "FAIL" with minimum % Offset16 for sensing condition; Sensor returns to Adjust mode 3. Return to RUN Mode. Method Action Result SET Button Move Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action required; sensor returns to RUN mode automatically 14 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 15 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds 16 See Troubleshooting on page 22 for more explanation of the % Offset displayed after the Dark SET method 20 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G1 Expert™ Dual Display Fiber Amplifier 3.4.6 Calibration SET • • Sets a threshold exactly at the presented condition Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust) A single sensing condition is presented, and the sensor positions a threshold exactly at the presented condition. When a condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting. Threshold position adjusted by Manual Adjust Sensor positions threshold exactly at the presented condition Output OFF Darkest (no signal) Output ON Condition Presented Most Light (saturated signal) Figure 11. Calibration SET (Light Operate shown) Calibration SET and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember: Auto Thresholding is automatically disabled in Calibration SET Follow these steps to perform a Calibration SET: Note: TEACH Selection must be programmed to CAL SEt. 1. Enter Adjust Mode Method Action SET Button 17 Remote Input 18 • Result Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold No action required; sensor is ready for Calibration SET method 2. SET Sensing Condition Method Action Result SET Button • • Present sensing condition Click the SET rocker button Remote Input • • Present sensing condition Single-pulse the remote input Threshold Condition Accepted Displays read "cAL SEt" then flashes "PASS"; Sensor returns to Adjust mode T Threshold Condition Unacceptable Displays read "cAL SEt" then flashes "FAIL"; Sensor returns to Adjust mode 17 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 18 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds www.bannerengineering.com - Tel: + 1 888 373 6767 21 DF-G1 Expert™ Dual Display Fiber Amplifier 3. Return to RUN Mode Method Action Result SET Button Move Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action required; sensor returns to RUN mode automatically 3.4.7 Troubleshooting Manual Adjustments Disabled Manual adjustments are disabled when Auto Thresholds are ON. If a manual adjustment is attempted while Auto Thresholds are ON, the Green display will flash . Percent Minimum Difference after TEACH The Two-Point and Dynamic TEACH methods will flash a % minimum difference on the displays after a PASS or FAIL. Value PASS/FAIL Description 0 to 99% FAIL The difference of the taught conditions does not meet the required minimum 100 to 300% PASS The difference of the taught conditions just meets/exceeds the required minimum, minor sensing variables may affect sensing reliability 300 to 600% PASS The difference of the taught conditions sufficiently exceeds the required minimum, minor sensing variables will not affect sensing reliability 600% + PASS The difference of the taught conditions greatly exceeds the required minimum, very stable operation Percent Offset after SET The Window, Dark, and Light SET methods will flash a % offset on the displays after a PASS or FAIL. SET Result % Offset Meaning PASS (with % Offset) Displays the % offset used for the SET method FAIL (with % Offset) Displays the minimum required % offset necessary to PASS the SET method FAIL (without % Offset) Presented condition cannot be used for the SET method Threshold Alert or Threshold Error Severe contamination/changes in the taught condition can prevent the Auto Thresholds algorithm from optimizing the threshold(s). State Display Description Corrective Action Threshold Alert Alternates The threshold(s) cannot be optimized, but the sensor's output will still continue to function Cleaning/correcting the sensing environment and/or a re-teach of the sensor is highly recommended The threshold(s) cannot be optimized, and the sensor's output will stop functioning Cleaning/correcting the sensing environment and/or a re-teach of the sensor is required and Threshold Error 22 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G1 Expert™ Dual Display Fiber Amplifier 4 IO-Link Interface IO-Link is a point-to-point communication link between a master device and sensor. Use IO-Link to parameterize sensors and transmit process data automatically. For the latest IO-Link protocol and specifications, see www.io-link.com. Each IO-Link device has an IODD (IO Device Description) file that contains information about the manufacturer, article number, functionality etc. This information can be easily read and processed by the user. Each device can be unambiguously identified via the IODD as well as via an internal device ID. Download the DF-G1 Expert Fiber Amplifier's IOLink IODD package (p/n 18491) from Banner Engineering's website at www.bannerengineering.com. Banner has also developed Add On Instruction (AOI) files to simplify ease-of-use between the DF-G1 Expert Fiber Amplifier, multiple third-party vendors' IO-Link masters, and the Logix Designer software package for Rockwell Automation PLCs. Three types of AOI files for Rockwell Allen-Bradley PLCs are listed below. These files and more information can be found at www.bannerengineering.com. Process Data AOIs—These files can be used alone, without the need for any other IO‐Link AOIs. The job of a Process Data AOI is to intelligently parse out the Process Data word(s) in separate pieces of information. All that is required to make use of this AOI is an EtherNet/IP connection to the IO‐Link Master and knowledge of where the Process Data registers are located for each port. Parameter Data AOIs—These files require the use of an associated IO‐Link Master AOI. The job of a Parameter Data AOI, when working in conjunction with the IO‐Link Master AOI, is to provide quasi‐realtime read/write access to all IO‐Link parameter data in the sensor. Each Parameter Data AOI is specific to a given sensor or device. IO‐Link Master AOIs—These files require the use of one or more associated Parameter Data AOIs. The job of an IO‐Link Master AOI is to translate the desired IO‐Link read/write requests, made by the Parameter Data AOI, into the format a specific IO‐Link Master requires. Each IO‐Link Master AOI is customized for a given brand of IO‐Link Master. Add and configure the relevant Banner IO‐Link Master AOI in your ladder logic program first; then add and configure Banner IO‐Link Device AOIs as desired, linking them to the Master AOI as shown in the relevant AOI documentation. www.bannerengineering.com - Tel: + 1 888 373 6767 23 DF-G1 Expert™ Dual Display Fiber Amplifier 5 Specifications Sensing Beam 660 nm visible red Supply Voltage NPN/PNP models: 10 to 30 V dc Class 2 (10% maximum ripple) IO-Link models: 18 to 30 V dc (10% maximum ripple) Power and Current Consumption (exclusive of load) Standard display mode: 960 mW, Current consumption < 40 mA at 24 V dc ECO display mode: 720 mW, Current consumption < 30 mA at 24 V dc Supply Protection Circuitry Protected against reverse polarity and transient overvoltages Delay at Power-Up 500 milliseconds maximum; outputs do not conduct during this time Output Configuration NPN/PNP models: 1 current sinking (NPN) or 1 current sourcing (PNP) output, depending on model IO-Link models: 1 push-pull and 1 PNP (complementary outputs) Repeatability High Speed: 66 µs, Standard/Long Range/Extra Long Range: 100 µs Connections PVC-jacketed 2 m or 9 m (6.5 ft. or 30 ft.) 4-wire integral cable; or integral 4-pin M8/Pico-style quick disconnect; or 150 mm (6 in.) cable with a 4-pin M12/Euro-style quick disconnect; or 150 mm (6 in.) cable with a 4-pin M8/ Pico-style quick disconnect. Output Rating 100 mA maximum load (derate 1 mA per °C above 30 °C) OFF-state leakage current: NPN/PNP models: < 5 μA at 30 V dc; IOLink models: < 50 μA at 30 V dc ON-state saturation voltage: NPN: < 1.5 V; PNP /IO-Link: < 2 V Output Protection Protected against output short-circuit, continuous overload, transient overvoltages, and false pulse on power-up Output Response Time High Speed: 200 µs Standard: 500 µs Long Range: 2 ms Extra Long Range: 5 ms Adjustments 3-way RUN/PRG/ADJ Mode Switch 2-way LO/DO Switch 3-way +/SET/- Rocker Button • Expert-style teaching (Two-Point and Dynamic TEACH, Light/Dark/Window/Calibration SET) • Manually adjust sensitivity (from "+" and "-" rocker button only) • Response Speed, TEACH Selection, Offset Percent, Auto Thresholds, Delays/Timers, Display Readout, Gain Selection, Factory Defaults (from top panel or remote input) • Top panel interface lockout (from remote input only) Factory Default Settings: Setting Factory Default Construction Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear polycarbonate cover Threshold 2026 TEACH Selection Two-Point TEACH IO-Link Interface Supports Smart Sensor Profile: Yes Baud Rate: 38,400 bps (COM2) Process Data Width: 16 bits IODD files: Provide all programming options of top panel interface, plus additional functionality, see IO-Link Interface on page 23 Response Speed Standard: 500 µs Offset Percent 10% Auto Thresholds OFF OFF Delay 0 (Disabled) OFF One-Shot 0 (Disabled) ON Delay 0 (Disabled) Indicators Red 4-digit Display: Signal Level Green 4-digit Display: Threshold (In Program Mode, Red and Green displays are used for programming menus) Yellow LED: Output conducting 24 ON One-Shot 0 (Disabled) Display Readout Numeric, ECO disabled, Normal Orientation Gain Selection Auto Gain www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G1 Expert™ Dual Display Fiber Amplifier Environmental Rating IEC IP50, NEMA 1 Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Operating Conditions Temperature: –10 °C to +55 °C (+14 °F to +131 °F) Storage Temperature: –20 °C to +85 °C (–4 °F to +185 °F) Humidity: 90% at +60 °C maximum relative humidity (noncondensing) Certifications Industrial Control Equipment 3TJJ 5.1 Excess Gain Curves Opposed Mode Diffuse Mode 0.25 mm (0.01 in) Diameter Fibers PIT16U PBT16U 1000 10000 XLR LR HS/STD XLR LR HS/STD EXCESS GAIN EXCESS GAIN 1000 100 100 10 10 1 1 0.1 1 10 100 0.1 DISTANCE (mm) 1 10 100 DISTANCE (mm) 0.51 mm (0.02 in) Diameter Fibers www.bannerengineering.com - Tel: + 1 888 373 6767 25 DF-G1 Expert™ Dual Display Fiber Amplifier Opposed Mode Diffuse Mode PIT26U PBT26U 100000 EXCESS GAIN 10000 EXCESS GAIN 10000 XLR LR HS/STD 1000 100 XLR LR HS/STD 1000 100 10 10 1 0.1 1 1 10 100 1000 0 DISTANCE (mm) 26 www.bannerengineering.com - Tel: + 1 888 373 6767 1 10 DISTANCE (mm) 100 DF-G1 Expert™ Dual Display Fiber Amplifier Opposed Mode Diffuse Mode 1.02 mm (0.04 in) Diameter Fibers PIT46U PBT46U 10000 100000 XLR LR HS/STD XLR LR HS/STD 1000 EXCESS GAIN EXCESS GAIN 10000 1000 100 10 10 1 100 1 10 100 1 1000 0.1 1 DISTANCE (mm) 10 100 1000 DISTANCE (mm) 1.52 mm (0.06 in) Diameter Fibers PIT66U PBT66U 100000 10000 10000 1000 1000 EXCESS GAIN EXCESS GAIN XLR LR HS/STD XLR LR HS/STD 100 10 100 10 1 1 1 10 100 1000 0.1 DISTANCE (mm) 1 10 100 1000 DISTANCE (mm) www.bannerengineering.com - Tel: + 1 888 373 6767 27 DF-G1 Expert™ Dual Display Fiber Amplifier 5.2 Beam Patterns Opposed Mode Diffuse Mode 0.25 mm (0.01 in) Diameter Fibers PIT16U 4 30 XLR LR HS/STD 10 0 -10 -20 -30 XLR LR HS/STD 3 BEAM WIDTH (mm) 20 BEAM WIDTH (mm) PBT16U 2 1 0 -1 -2 -3 -4 0 5 10 15 20 25 30 35 40 45 50 0 2 4 6 8 10 12 DISTANCE (mm) DISTANCE (mm) 0.51 mm (0.02 in) Diameter Fibers PIT26U PBT26U 150 15 XLR LR HS/STD 50 0 -50 5 0 -5 -10 -100 -150 XLR LR HS/STD 10 BEAM WIDTH (mm) BEAM WIDTH (mm) 100 0 20 40 60 80 100 120 140 -15 0 10 20 DISTANCE (mm) 28 www.bannerengineering.com - Tel: + 1 888 373 6767 30 40 50 DISTANCE (mm) 60 70 80 DF-G1 Expert™ Dual Display Fiber Amplifier Opposed Mode Diffuse Mode 1.02 mm (0.04 in) Diameter Fibers PIT46U PBT46U 80 400 XLR LR HS/STD XLR LR HS/STD 60 40 200 BEAM WIDTH (mm) BEAM WIDTH (mm) 300 100 0 -100 -200 20 0 -20 -40 -60 -300 -80 -400 0 100 200 300 400 500 600 700 0 800 20 40 60 80 100 120 140 160 180 200 DISTANCE (mm) DISTANCE (mm) 1.52 mm (0.06 in) Diameter Fibers PIT66U 200 600 XLR LR HS/STD 500 400 100 300 200 100 0 -100 -200 -300 -400 50 0 -50 -100 -150 -500 -600 XLR LR HS/STD 150 BEAM WIDTH (mm) BEAM WIDTH (mm) PBT66U -200 0 100 200 300 400 500 600 700 800 0 900 1000 40 80 120 160 200 240 280 320 DISTANCE (mm) DISTANCE (mm) 0 www.bannerengineering.com - Tel: + 1 888 373 6767 29 DF-G1 Expert™ Dual Display Fiber Amplifier 5.3 Dimensions 30 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G1 Expert™ Dual Display Fiber Amplifier 6 Accessories DIN-35-.. 35 mm DIN Rail Model Length DIN-35-70 70 DIN-35-105 105 DIN-35-140 140 L 35 SA-DIN-CLAMP • Pair of metal DIN rail end stops; slide onto DIN rail at either side of the sensor stack • Combination (#2 Phillips, #8 standard slotted) set screw L = 70, 105 or 140 mm Hole center spacing: 35.1 9.1 mm (0.63") Hole size: 25.4 x 5.3 9.1 mm (0.36") 45.0 mm (1.77") SA-DIN-BRACKET • Plastic bracket with mounting screws 10 SA-DIN-BRACKET-10 • Package of 10 plastic brackets with mounting screws 35 10 35 Hole center spacing: A = 16, B = 25.4, C = 15.2 Hole center spacing: A = 16, B = 25.4, C = 15.2 Hole size: A = ø 3.2, B = ø 3.3, C = ø 4.4 Hole size: A = ø 3.2, B = ø 3.3, C = ø 4.4 6.1 Quick-Disconnect Cordsets All measurements are listed in millimeters, unless noted otherwise. 4-Pin Threaded M12/Euro-Style Cordsets—Single Ended Model Length MQDC-406 1.83 m (6 ft) MQDC-415 4.57 m (15 ft) MQDC-430 9.14 m (30 ft) MQDC-450 15.2 m (50 ft) MQDC-406RA 1.83 m (6 ft) MQDC-415RA 4.57 m (15 ft) MQDC-430RA 9.14 m (30 ft) MQDC-450RA 15.2 m (50 ft) Style Dimensions Pinout (Female) 44 Typ. Straight M12 x 1 ø 14.5 1 4 2 3 32 Typ. [1.26"] 30 Typ. [1.18"] Right-Angle M12 x 1 ø 14.5 [0.57"] www.bannerengineering.com - Tel: + 1 888 373 6767 1 = Brown 2 = White 3 = Blue 4 = Black 31 DF-G1 Expert™ Dual Display Fiber Amplifier 4-Pin Threaded M8/Pico-Style Cordsets—Single Ended Model Length PKG4M-2 2 m (6.56 ft) PKG4M-5 5 m (16.4 ft) Style Dimensions 35 Typ. Straight PKG4M-9 9 m (29.5 ft) PKW4M-2 2 m (6.56 ft) PKW4M-5 ø 9.5 M8 x 1 4 2 1 3 28 Typ. 5 m (16.4 ft) 9 m (29.5 ft) 1 = Brown 2 = White 3 = Blue 4 = Black 20 Typ. Right Angle PKW4M-9 Pinout (Female) M8 x 1 ø 9.5 4-Pin Snap-on M8/Pico-Style Cordsets—Single Ended Model Length PKG4-2 2 m (6.6 ft) PKG4-5 5 m (16.4 ft) Style Dimensions Pinout (Female) 32 Typ. Straight PKG4-10 10 m (32.8 ft) PKW4Z-2 2 m (6.6 ft) PKW4Z-5 5 m (16.4 ft) ø 9.0 15 Typ. ø 10.9 32 www.bannerengineering.com - Tel: + 1 888 373 6767 2 1 3 29 Typ. Right-Angle 4 1 = Brown 2 = White 3 = Blue 4 = Black DF-G1 Expert™ Dual Display Fiber Amplifier 7 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. www.bannerengineering.com - Tel: + 1 888 373 6767 33
DF-G1-NS-2M 价格&库存

很抱歉,暂时无法提供与“DF-G1-NS-2M”相匹配的价格&库存,您可以联系我们找货

免费人工找货