DF-G3 Long Range Expert™ Dual Display
Fiber Amplifier
Instruction Manual
Original Instructions
187436 Rev. G
10 September 2021
© Banner Engineering Corp. All rights reserved
187436
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Contents
1 Product Description
...................................................................................................................................................... 3
1.1 Models
.............................................................................................................................................................................................3
1.2 Overview
......................................................................................................................................................................................... 4
1.3 Top Panel Interface
.........................................................................................................................................................................4
2 Installation Instructions
............................................................................................................................................... 6
2.1 Mounting Instructions
......................................................................................................................................................................6
2.2 Installing the Fibers in a DF-Gx Sensor
........................................................................................................................................... 6
2.3 Fiber Adapters
.................................................................................................................................................................................7
2.4 Wiring Diagrams
..............................................................................................................................................................................7
3 Operating Instructions
................................................................................................................................................. 9
3.1 Run Mode
........................................................................................................................................................................................9
3.2 Program Mode
.............................................................................................................................................................................. 10
3.2.1 Output Selection
.................................................................................................................................................................... 11
3.2.2 TEACH Selection
...................................................................................................................................................................12
3.2.3 Response Speed
................................................................................................................................................................... 12
3.2.4 Offset Percent
........................................................................................................................................................................12
3.2.5 Auto Thresholds
.................................................................................................................................................................... 12
3.2.6 Delays/Timers
........................................................................................................................................................................13
3.2.7 Sensitivity Selection
...............................................................................................................................................................13
3.2.8 Input Wire Function
............................................................................................................................................................... 13
3.2.9 Display Readout
.................................................................................................................................................................... 13
3.2.10 Gain Selection
..................................................................................................................................................................... 14
3.2.11 Factory Defaults
.................................................................................................................................................................. 14
3.3 Remote Input
..................................................................................................................................................................................14
3.4 Sync Master/Slave
........................................................................................................................................................................ 15
3.5 Adjust Mode
.................................................................................................................................................................................. 16
3.5.1 Two-Point TEACH
.................................................................................................................................................................. 16
3.5.2 Dynamic TEACH
.................................................................................................................................................................... 17
3.5.3 Window SET
...........................................................................................................................................................................19
3.5.4 Light SET
................................................................................................................................................................................21
3.5.5 Dark SET
............................................................................................................................................................................... 22
3.5.6 Calibration SET
...................................................................................................................................................................... 24
3.6 Troubleshooting
............................................................................................................................................................................ 25
3.6.1 Manual Adjustments Disabled
............................................................................................................................................... 25
3.6.2 Percent Minimum Difference after TEACH
............................................................................................................................25
3.6.3 Percent Offset after SET
....................................................................................................................................................... 25
3.6.4 Threshold Alert or Threshold Error
........................................................................................................................................ 26
4 Specifications
............................................................................................................................................................. 27
4.1 Excess Gain Curves
......................................................................................................................................................................29
4.2 Beam Patterns
............................................................................................................................................................................... 31
4.3 Dimensions
.................................................................................................................................................................................... 33
5 Accessories
.................................................................................................................................................................34
5.1 Quick-Disconnect Cordsets—Single Output Models
.....................................................................................................................34
5.2 Quick-Disconnect Cordsets—Dual Output Models
....................................................................................................................... 35
5.3 Banner Engineering Corp. Limited Warranty
................................................................................................................................ 37
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
1 Product Description
Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies; single or dual discrete output
models are available.
•
•
•
•
•
World-class long-range sensing capability, more than 6 m (20 ft) with opposed mode fibers
Models with high visibility red, extreme high-power infrared and water-detecting long infrared sensing beams available
Cross-talk avoidance function allows seven inspections in dense sensing point applications
Energy efficient light resistance enables stable detection in industrial lighting environments
High power amplifier with small core fibers enables precise position sensing of small components
•
•
•
•
•
•
•
•
Easy to read dual digital displays show both signal level and threshold simultaneously
Lever action fiber clamp provides stable, reliable, and trouble-free fiber clamping
Simple user interface ensures easy sensor set-up and programming via displays and switches/
buttons or remote input teach wire
Expert TEACH and SET methods ensure optimal gain and threshold for all applications,
especially for high speed or low contrast applications
User has full control over all operating parameters: threshold, Light Operate or Dark Operate,
output timing functions, gain level, and response speed
Thermally stable electronics shorten start-up time and maintain signal stability during operation
ECO (economy) display mode reduces amplifier power consumption by 25%
Sleek 10 mm wide housing mounts to 35 mm DIN rail
WARNING:
• Do not use this device for personnel protection
• Using this device for personnel protection could result in serious injury or death.
• This device does not include the self-checking redundant circuitry necessary to allow its use in
personnel safety applications. A device failure or malfunction can cause either an energized (on)
or de-energized (off) output condition.
1.1 Models
Model
Sensing Beam Color
Reference Sensing Range 1
Outputs
DF-G3-NS-2M
Single NPN
DF-G3-PS-2M
Single PNP
Connector 2
2 m (6.5 ft) cable, 4-wire
Visible Red
3000 mm
DF-G3-ND-2M
Dual Independent NPN
DF-G3-PD-2M
Dual Independent PNP
2 m (6.5 ft) cable, 5-wire
DF-G3IR-NS-2M
Single NPN
DF-G3IR-PS-2M
Single PNP
2 m (6.5 ft) cable, 4-wire
Infrared, 850 nm
6000 mm
DF-G3IR-ND-2M
Dual Independent NPN
DF-G3IR-PD-2M
Dual Independent PNP
2 m (6.5 ft) cable, 5-wire
Water Detection Models
DF-G3LIR-NS-2M
Single NPN
Long infrared, 1450 nm
DF-G3LIR-PS-2M
900 mm
2 m (6.5 ft) cable, 4-wire
Single PNP
1 Excess gain = 1 (high sensitivity), opposed mode sensing. PIT46U plastic fiber used for visible LED models, IT.83.3ST5M6 glass fiber used for IR
models.
2 Connector options:
•
A model with a QD connector requires a mating cordset (see Quick-Disconnect Cordsets—Single Output Models on p. 34)
•
For 9 m (29.5 ft) cable, change the suffix 2M to 9M in the 2 m model number (DF-G3-NS-9M)
•
For 150 mm (6 in) PVC cable with a M8/Pico-style QD model, change the suffix 2M to Q3 in the 2 m model number (DF-G3-NS-Q3)
•
For 150 mm (6 in) PVC cable with a M12/Euro-style model, change the suffix 2M to Q5 in the 2 m model number (DF-G3-NS-Q5)
•
For integral M8/Pico-style model, change the suffix 2M to Q7 in the 2 m model number (DF-G3-NS-Q7)
•
For Q3 and Q7 Dual Output models, use a 5-pin M8/Pico-style or a 6-pin M8/Pico-style mating cordset
www.bannerengineering.com - Tel: + 1 888 373 6767
3
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Model
Sensing Beam Color
Reference Sensing Range 1
Connector 2
Outputs
DF-G3LIR-ND-2M
Dual Independent NPN
DF-G3LIR-PD-2M
Dual Independent PNP
2 m (6.5 ft) cable, 5-wire
1.2 Overview
Figure 1. DF-G3 Single Output
Figure 2. DF-G3 Dual Output
1
Single Output LED or Dual Output LEDs
2
LO/DO Switch (Single Output) or CH1/CH2
Switch (Dual Output)
3
RUN/PRG/ADJ Mode Switch
4
Lever Action Fiber Clamp
5
Red Signal Level
6
Green Threshold
7
+/SET/- Rocker Button
1.3 Top Panel Interface
Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ
mode switch, LO/DO or CH1/CH2 switch, +/SET/- rocker button, dual red/green digital displays, and output LED(s).
RUN/PRG/ADJ Mode Switch
The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode.
• RUN mode allows the sensor to operate normally and prevents unintentional programming
changes via the +/SET/- rocker button.
• PRG mode allows the sensor to be programmed through the display-driven programming menu
(see Program Mode).
• ADJ mode allows the user to perform Expert TEACH/SET methods and Manual Adjust (see Adjust
Mode on p. 16).
1 Excess gain = 1 (high sensitivity), opposed mode sensing. PIT46U plastic fiber used for visible LED models, IT.83.3ST5M6 glass fiber used for IR
models.
2 Connector options:
•
A model with a QD connector requires a mating cordset (see Quick-Disconnect Cordsets—Single Output Models on p. 34)
•
For 9 m (29.5 ft) cable, change the suffix 2M to 9M in the 2 m model number (DF-G3-NS-9M)
•
For 150 mm (6 in) PVC cable with a M8/Pico-style QD model, change the suffix 2M to Q3 in the 2 m model number (DF-G3-NS-Q3)
•
For 150 mm (6 in) PVC cable with a M12/Euro-style model, change the suffix 2M to Q5 in the 2 m model number (DF-G3-NS-Q5)
•
For integral M8/Pico-style model, change the suffix 2M to Q7 in the 2 m model number (DF-G3-NS-Q7)
•
For Q3 and Q7 Dual Output models, use a 5-pin M8/Pico-style or a 6-pin M8/Pico-style mating cordset
4
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
LO/DO Switch (Single Output Models)
The LO/DO switch selects Light Operate or Dark Operate mode.
• In Light Operate mode, the output is ON when the sensing condition is above the threshold. (For
Window SET, the output is ON when the sensing condition is inside the window.)
• In Dark Operate mode, the output is ON when the sensing condition is below the threshold. (For
Window SET, the output is ON when the sensing condition is outside the window.)
CH1/CH2 Switch (Dual Output Models)
The CH1/CH2 switch selects which output's parameters can be accessed and changed in the interface of
the display.
+/SET/- Rocker Button
The +/SET/- rocker button is a 3-way button. The +/- positions are engaged by rocking the button left/right.
The SET position is engaged by clicking down the button while the rocker is in the middle position. All
three button positions are used during PRG mode to navigate the display-driven programming menu.
During ADJ mode, SET is used to perform TEACH/SET methods and +/- are used to manually adjust the
threshold(s). The rocker button is disabled during RUN mode, except when using Window SET (see
Window SET).
Red/Green Digital Displays
During RUN and ADJ modes, the Red display shows the signal level, and the Green display shows the
threshold or the total counts. During PRG mode, both displays are used to navigate the display-driven
programming menu.
Single Output LED
The output LED provides a visible indication when the output is activated.
Dual Output LEDs
The output LEDs provide a visible indication when the associated output is active.
• 1 represents the Channel 1 output.
• 2 represents the Channel 2 output.
www.bannerengineering.com - Tel: + 1 888 373 6767
5
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
2 Installation Instructions
2.1 Mounting Instructions
Mount on a DIN Rail
1. Hook the DIN rail clip on the bottom of the DF-G3
over the edge of the DIN rail (1).
2. Push the DF-G3 up on the DIN rail (1).
3. Pivot the DF-G3 onto the DIN rail, pressing until it
snaps into place (2).
Mount to the Accessory Bracket (SA-DIN-BRACKET)
1. Position the DF-G3 in the SA-DIN-BRACKET.
2. Insert the supplied M3 screws.
3. Tighten the screws.
Remove from a DIN rail
1. Push the DF-G3 up on the DIN rail (1).
2. Pivot the DF-G3 away from the DIN rail and remove
it (2).
2.2 Installing the Fibers in a DF-Gx Sensor
Follow these steps to install glass or plastic fibers.
1.
2.
3.
4.
5.
Open the dust cover.
Move the fiber clamp forward to unlock it.
Insert the fiber(s) into the fiber port(s) until they stop.
Move the fiber clamp backward to lock the fiber(s).
Close the dust cover.
Move forward
to release the
fibers
Fiber Clamp
Fiber Receiver
Port
Fiber Emitter
Port
Note: For optimum performance of IR models, if applicable, glass fibers must be used.
6
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
2.3 Fiber Adapters
Note: If a thin fiber with less than 2.2 mm outer diameter is used, install the fiber adapter provided with the
fiber assembly to ensure a reliable fit in the fiber holder. Align the fibers to the end of the adaptors. Banner
includes the adapters with all fiber assemblies.
TO
FIBERS
TO
SENSOR
Fiber Outer Diameter (mm)
Adapter Color
Ø 1.0
Black
Ø 1.3
Red
Ø 2.2
No adapter needed
When connecting coaxial-type fiber assemblies to the amplifier, install the single-core (center) fiber to the Transmitter port,
and the multi-core (outer) fiber to the Receiver port. This will result in the most reliable detection.
RECEIVER
Multi-core fiber
Single-core fiber
TRANSMITTER
2.4 Wiring Diagrams
Single Output
NPN Models
PNP Models
Key
10–30 V dc
10-30V dc
Load
Load
1 = Brown
2 = White
3 = Blue
4 = Black
Input Wire
Input Wire
Note: Open lead wires must be connected to a terminal block.
www.bannerengineering.com - Tel: + 1 888 373 6767
7
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Dual Output
NPN Models
3
–
10–30 V dc
+
1
4
2
5
PNP Models
1
2
Out 1
Input Wire
+
10–30 V dc
–
3
4
Out 2
5
Key
Out 2
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
(6 = no connection)
Out 1
Input Wire
Note: Open lead wires must be connected to a terminal block.
Note: When using multiple sensors in Master/Slave mode, the gray wires from each sensor should be
connected together. The remote programming function cannot be used.
8
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
3 Operating Instructions
3.1 Run Mode
Run mode allows the sensor to operate normally and prevents unintentional programming changes. The +/SET/- rocker
button is disabled during RUN mode, except when using Window SET.
www.bannerengineering.com - Tel: + 1 888 373 6767
9
Menu
List
diSP 1234
GAin SEL
Auto
Note: The LO/DO
selection is not available
in the Single Output
menu.
10
Return to Menu List
diSP rEAd
www.bannerengineering.com - Tel: + 1 888 373 6767
Menu available
in Lt, dr or wind
set only
oFF
Click SET
to enter choice list
Click SET
to set value
to set value
to set value
Click SET
to set value
Click SET
Click SET
to set value
Click SET
to set value
Click SET
on display represents a “w”
DISPLAY
LOOP
Click SET
to enter choice list
DISPLAY
LOOP
Click SET
to enter choice list
on display represents a “m”
Click SET to select and save a choice in any list
Menu not
available when
in cal set
inPt SEL
to set value
Std
DISPLAY
LOOP
SEnS SEL1
DISPLAY
LOOP
oFF
DISPLAY
LOOP
dLY SEL1
DISPLAY
LOOP
oFF
DISPLAY
LOOP
Auto Thr1
to set value
Click SET
to set value
Click SET
(display flips 180˚)
DISPLAY
LOOP
Fixed Gain Set
DISPLAY
LOOP
Click SET
to enter choice list
10 Pct
Click SET
to enter choice list
OFSt Pct1
Click SET
to enter choice list
2 ms
Click SET
to enter choice list
rESP SPd
Click SET
to enter choice list
2-pt tch
Click SET
to enter choice list
tch SEL1
setting-specific
CH1 Factory Default Settings:
Click SET
to enter choice list
default setting
rocker button
LO
To scroll through menu lists: Press “+” or “-”
To enter a choice list or to select and save: Click SET
To exit a choice list without saving: Press and hold SET for 2 seconds
Out SEL1 (dual
only)
Switch Mode
to “PRG”
DISPLAY
LOOP
Click SET
to enter choice list
Channel 1 Menu
Program (PRG) mode allows the following
settings to be programmed in the DF-G3.
Press and hold SET to exit
choice list without saving
PROGRAM MODE
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
3.2 Program Mode
on display represents a “m”
on display represents a “w”
Return to Menu List
Click SET to select and save a choice in any list
(+) or (-)
to set value
(+) or (-)
to set value
Available in
Lt, dr or wind
set only
(+) or (-)
to set value
Not available
in CAL Set
DISPLAY
LOOP
Click SET
(+) or (-)
to set value
(+) or (-)
to set value
Click SET
Click SET
Click SET
to set value
to set value
(+) or (-)
(+) or (-)
DISPLAY
LOOP
Click SET
to enter choice list
Click SET
Click SET
setting-specific
Menu
List
Switch Mode
to “PRG”
PROGRAM MODE
The factory default settings for CH2 and CH1
are the same.
DISPLAY
LOOP
std
DISPLAY
LOOP
SenS CH2
DISPLAY
LOOP
oFF
DISPLAY
LOOP
dLY SEL2
Click SET
to enter choice list
oFF
Click SET
to enter choice list
Auto Thr2
Click SET
to enter choice list
10 pct
Click SET
to enter choice list
OFSt Pct2
Click SET
to enter choice list
2-pt tch
other menus hidden
tch SEL2
default setting
LO
rocker button
Out SEL2
Press and hold SET to exit
choice list without saving
Channel 2 Menu
Program (PRG) mode allows the following
settings to be programmed in the DF-G3.
The LO/DO switch is replaced with the
CH1/CH2 selection switch. LO/DO is
selected via the Program Mode menu.
Setting the switch to CH1 allows the settings
in the Program Mode chart to be
programmed globally for CH1 and CH2.
When CH2 is selected in Program mode, the
settings below can be configured for CH2
and are independent from CH1 settings.
CH2 Factory Default Settings:
To scroll through menu lists: Press “+” or “-”
To enter a choice list or to select and save: Click SET
To exit a choice list without saving: Press and
hold SET for 2 seconds
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
3.2.1 Output Selection
Both CH1 and CH2 can be programmed for either light operate (LO) or dark operate (DO). The Channel 2 menu includes two
additional menus: Health (Health Mode Alarm) and Comp (Complementary Programming).
Health Mode Alarm
The Health Mode Alarm alerts you when preventative maintenance becomes necessary to ensure reliable sensing. The
Health Mode output 2 is Active when the system is OK and operating normally. Health Mode output 2 becomes Inactive when
the system is in a marginal state because of contamination. The system still operates normally and can detect small objects,
but is nearing the alarm state. When the system is completely contaminated and unable to ensure reliable sensing, the
system goes into the alarm state. In the alarm state, the discrete output 1 is forced to the blocked state and can no longer be
used to detect small objects.
•
Threshold Alert
displays when Health Mode output 2 is inactive because of contamination. The system
operates normally but is nearing the alarm state.
•
Threshold Error
used to detect small objects.
displays when discrete output 1 is forced to the blocked state and can no longer be
The sensor may enter Health Mode Alarm for any of these reasons:
1. When first powered up; the fiber optic array may already be contaminated
www.bannerengineering.com - Tel: + 1 888 373 6767
11
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
2. If the Window SET procedure fails, indicating the fiber optic array is contaminated and the sensor could not set a
valid clear-state light level for reliable detection
3. If the fiber optic array is contaminated enough that the auto compensation tracking algorithm cannot sufficiently adjust
the thresholds to ensure reliable detection
4. If the fiber optic array is blocked for more than 2 seconds
Return the system to normal operation by cleaning the fiber optic array and performing a Window SET to reset the clear-state
light level (see Window SET on p. 19).
Complementary Programming
When CH2 is selected for Comp (Complementary) operation, its output always switches to the opposite state of CH1.
3.2.2 TEACH Selection
The DF-G3 can be programmed for one of the following TEACH/SET methods:
• Two-Point TEACH
• Dynamic TEACH
• Window SET
• Light SET
• Dark SET
• Calibration SET
Note: A TEACH Selection must be selected by programming before TEACH/SET methods can be used.
3.2.3 Response Speed
The DF-G3 can be programmed for one of the following Response Speeds:
Description
Response
Speed
Repetition
Period
Repeatability
Cross-Talk
Avoidance
Energy Efficient
Light Resistance
Maximum
Range, Red 3
Maximum
Range, IR850 4
High Speed
500 µs
100 µs
100 µs
No
No
1200 mm
2400 mm
Fast
1000 µs
100 µs
150 µs
Yes
No
1500 mm
3000 mm
Standard
2 ms
100 µs
180 µs
Yes
Yes
1500 mm
3000 mm
Long Range
8 ms
100 µs
180 µs
Yes
Yes
1950 mm
3900 mm
Extra Long Range
24 ms
100 µs
180 µs
Yes
Yes
3000 mm
6000 mm
3.2.4 Offset Percent
The Offset Percent is used during the Window, Light, or Dark SET methods. The threshold(s) are positioned a programmable
% offset from the taught condition.
The allowable range is 5% minimum to 95% maximum for all response speeds.
The offset percent can also be programmed to Minimum Offset. This allows the DF-G3 to set the
threshold(s) as close as possible to the presented condition, but still provide for reliable sensing.
Note: Offset Percent MUST be programmed to Minimum Offset for Dark SET to accept conditions of no
signal (0 counts).
3.2.5 Auto Thresholds
Auto Thresholds can be programmed to be ON/OFF. The Auto Thresholds algorithm continuously tracks slow changes in the
taught condition(s), and optimizes the threshold(s) to provide for reliable sensing. For Two-Point and Dynamic TEACH, the
algorithm optimizes the threshold to be centered between the light and dark conditions. For Window, Light, and Dark SET,
the algorithm optimizes the threshold(s) to maintain the programmed Offset Percent from the taught condition.
• After programming Auto Thresholds to ON, it is highly recommended to re-perform the TEACH/SET method
• Manual Adjustments are disabled when Auto Thresholds are ON
3 Excess gain = 1 (high sensitivity), opposed mode sensing. PIT46U plastic fiber used for visible LED models.
4 Excess gain = 1 (high sensitivity), opposed mode sensing. IT.83.3ST5M6 glass fiber used for IR models.
12
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
•
•
Auto Thresholds are automatically disabled in Calibration SET (see Calibration SET on p. 24)
Severe contamination/changes in the taught condition can prevent the Auto Thresholds algorithm from optimizing the
threshold(s). If this occurs, the DF-G3 enters a Threshold Alert or Threshold Error state. See Troubleshooting on p.
25 for more explanation.
3.2.6 Delays/Timers
ON/OFF Delays and ON/OFF One-Shot
timers can be programmed independently for
both CH1 and CH2 for a time period
between between 1 - 9999 ms (a value of 0
disables the delay/timer). Figure 3 on p. 13
defines how the delays/timers affect the
output behavior.
Some combinations of delays/timers are not
allowed. The DF-G3 programming menu
automatically disables invalid combinations
of delays/timers. The following table shows
the allowable combinations of delays/timers:
Figure 3. DF-G3 Delays/Timers
ON
Output
OFF
OFF Delay
OFF 1-Shot
D
D
D
D
ON Delay
D
D
ON 1-Shot
D
D
Time
(D = 1 - 9999 ms)
OFF Delay
OFF One-Shot Timer
ON Delay
ON One-Shot Timer
-
OK
OK
N/A
OFF One-Shot Timer
OK
-
N/A
N/A
ON Delay
OK
N/A
-
OK
ON One-Shot Timer
N/A
N/A
OK
-
OFF Delay
3.2.7 Sensitivity Selection
The Sensitivity Selection can be programmed independently for CH1 and CH2. Use this setting to increase (lo) or decrease
(high) the switch-point hysteresis from the default (std) setting.
• high—High sensitivity. Use this setting for low contrast sensing
• Std—Standard sensitivity
• Lo—Low sensitivity. Use this setting to stabilize the output in high vibration applications
3.2.8 Input Wire Function
The DF-G3 can be programmed for one of the following input wire functions:
• Off—Ignore all pulses
• Set—Remote TEACH input
• Master—Master sync line output for multi-sensor cross-talk avoidance
• Slave—Slave sync line output for multi-sensor cross-talk avoidance
• LED off—When the input wire is active the emitter LED turns off
• LED on—When the input wire is active the emitter LED turns on
• Gate—When the input wire is active the outputs are locked in their present state; any active delay timers are paused
For remote programming in Set Mode see Remote Input on p. 14.
To configure sensors for master-slave operation, see Sync Master/Slave on p. 15.
3.2.9 Display Readout
The readout of the digital displays can be programmed for the following options:
• Signal/Threshold readout - Numeric (1234) or % (123P)
www.bannerengineering.com - Tel: + 1 888 373 6767
13
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
•
•
ECO mode - Enabled or Disabled (ECO mode dims the displays to reduce current consumption)
Display Orientation - Normal (
) or Flipped (
)
3.2.10 Gain Selection
The DF-G3 can operate in Auto Gain mode or the Gain can be fixed to be in Gain 1...7. In Auto Gain, the DF-G3 optimizes
the gain during a TEACH/SET method for the presented condition(s). While viewing the fixed gains in the Gain Selection
choice list, the DF-G3 will automatically switch to the selected gain and display the measured signal on the Red display. This
allows for easy and quick evaluation of the fixed gain mode.
3.2.11 Factory Defaults
The Factory Defaults menu allows the DF-G3 to be easily restored back to original factory default settings (see Factory
Default Settings in Specifications).
3.3 Remote Input
Use the input wire to program the sensor remotely. To program the sensor using the input wire, remote input must be
enabled (inPt SEL = SEt, see Input Wire Function on p. 13). The remote input provides limited programming options (see the
figure below). Pulse the remote input according to the figures and the instructions provided in this manual.
Note: For NPN models, the remote input pulses are active low as shown in the following figures. For PNP
models, the remote input pulses are active high and are inverted from the following figures.
Figure 4. Single Output—Remote Input Flowchart
REMOTE TEACH
Remote
Input
NOTE: Follow procedure for the selected TEACH/SET method
(highlighted in black box) chosen in the TEACH Selection menu
1x
Starts Selected Teach
Remote Setup
REMOTE SETUP
1x
Teach Selection
1x
Two-Point
2x
Dynamic
3x
One-Point Window
4x
One-Point Light Set
5x
One-Point Dark Set
6x
CAL Set
Button Lock (loc) or Unlock (uloc)
4x
8x
14
Completes Teach
1x
3x
Pulse Timing (T)
0.04 seconds < T < 0.8 seconds
Timing between Pulse groups > 1 second
1x
Button Unlock (uloc)
2x
Button Lock (loc)
Factory Default Settings
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Figure 5. Dual Output—Remote Input Flowchart
REMOTE TEACH
Remote
Input
NOTE: Follow procedure for the selected TEACH/SET method
(highlighted in black box) chosen in the TEACH Selection menu
1x
Starts Selected Teach for CH1
1x
Completes Teach for CH1
2x
Starts Selected Teach for CH2
1x
Completes Teach for CH2
3x
Remote Setup
REMOTE SETUP
1x
2x
Teach Selection CH1
1x
Two-Point
2x
Dynamic
3x
One-Point Window
3x
One-Point Light Set
5x
One-Point Dark Set
6x
Cal SET
LO/DO Selection CH1
LO
DO
1x
2x
3x
Teach Selection CH2
1x
Two-Point
2x
Dynamic
3x
One-Point Window
4x
One-Point Light Set
5x
One-Point Dark Set
Cal SET
6x
4x
LO/DO Selection CH2
LO
DO
1x
2x
Button Lock (loc) or Unlock (uloc)
4x
8x
Pulse Timing (T)
0.04 seconds < T < 0.8 seconds
Timing between Pulse groups > 1 second
1x
Button Unlock (uloc)
2x
Button Lock (loc)
Factory Default Settings
3.4 Sync Master/Slave
Up to seven DF-G3 Long Range Expert Dual Display Fiber Amplifier sensors may be used together in a single sensing
application. To eliminate crosstalk between the sensors, configure one sensor to be the master and the remaining sensors to
be the slaves. In this mode, the sensors alternate taking measurements and the response speed is 2 ms.
Note: Note: In this mode, all sensors must either be NPN or PNP output models.
www.bannerengineering.com - Tel: + 1 888 373 6767
15
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
1.
2.
3.
4.
5.
Configure the first sensor as the Master (inPt SEL = MAST).
In the Master sensor set-up, enter the total number of Slave sensors you will be using (tOtL SLAV = 1 - 6).
For each Slave sensor used, configure the input as a Slave (inPt SEL = SLVE).
Give each Slave its own identifying address (SLAV Addr = 1 - 6).
Connect the Input wires of the Master and all of the Slaves together.
Note: Note: Giving two Slave sensors the same address will cause them to fire their emitters at the same
time in the firing sequence.
3.5 Adjust Mode
Sliding the RUN/PRG/ADJ mode switch to the ADJ position allows the user to perform Expert TEACH/SET methods and
Manual Adjustment of the threshold(s).
Note: For the Dual Output models, when teaching CH2, the gain setting will be the same as the gain
setting made during the CH1 teach. Reteaching CH1 may invalidate the previous CH2 teach.
3.5.1 Two-Point TEACH
•
•
Establishes a single switching threshold
Threshold can be adjusted by using the "+" and "-" rocker button (Manual Adjust)
Two-Point TEACH is used when two conditions can be presented statically to the sensor. The sensor locates a single
sensing threshold (the switch point) midway between the two taught conditions, with the Output ON condition on one side,
and the Output OFF condition on the other.
Figure 6. Two-Point TEACH (Light Operate shown)
Darkest Taught
Condition
Lightest Taught
Condition
Sensor positions
threshold midway
between taught conditions
Output OFF
Darkest
(no signal)
Output ON
Position
adjusted by
Manual Adjust
Most Light
(saturated
signal)
The Output ON and OFF conditions can be reversed by using the LO/DO (Light Operate/ Dark Operate) switch or through
the program interface for the dual output model.
Two-Point TEACH and Manual Adjust
Moves switching threshold value up or down to make adjustments
•
•
•
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
◦ GREEN display shows the switching threshold value
◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Two-Point TEACH:
Note: TEACH Selection must be programmed to 2Pt tcH.
1. Enter Adjust mode.
16
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Method
Action
Result
SET Button 5
Set the Mode switch to ADJ.
Display: Red - Signal Level; Green Threshold
Remote Input 6
No action is required; sensor is ready for
the Two-Point TEACH method
2. Teach the first condition.
Method
Action
Result
SET Button
a. Present the first condition.
b. Click the SET rocker button.
Display: Flashes "2Pt tch" then holds
on "1234 2nd"
Remote Input
a. Present the first condition.
b. Single-pulse the remote input.
T
3. Teach the second condition.
Method
Action
Result
SET Button
a. Present the second condition.
b. Click the SET rocker button.
TEACH Accepted
Remote Input
a. Present the second condition.
b. Single-pulse the remote input.
Displays alternate "PASS" and %
Minimum Difference 7; Sensor returns
to Adjust mode
T
TEACH Not Accepted
Displays alternate "FAIL" and %
Minimum Difference 7; Sensor returns
to Adjust mode
4. Return to Run mode.
Method
Action
Result
SET Button
Move the Mode switch to RUN
Display: Red - Signal Level; Green Threshold
Remote Input
No action is required; sensor returns to
RUN mode automatically
3.5.2 Dynamic TEACH
•
•
•
Teaches on-the-fly
Establishes a single switching threshold
Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actual
sensing conditions, taking multiple samples of the light and dark conditions and automatically setting the threshold at the
optimum level.
5 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
6 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
7 See Troubleshooting on p. 25 for more explanation of the % Minimum Difference displayed after the Two-Point TEACH method.
www.bannerengineering.com - Tel: + 1 888 373 6767
17
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Figure 7. Dynamic TEACH (Light Operate shown)
Darkest Taught
Condition
Lightest Taught
Condition
Sensor positions
threshold midway
between taught conditions
Output OFF
Darkest
(no signal)
Output ON
Position
adjusted by
Manual Adjust
Most Light
(saturated
signal)
The Output ON and OFF conditions can be reversed by using the LO/DO (Light Operate/ Dark Operate) switch or through
the program interface for the dual output model.
Dynamic TEACH and Manual Adjust
Moves switching threshold value up or down to make adjustments
•
•
•
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
◦ GREEN display shows the switching threshold value
◦ 2 seconds after adjustment, GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform Dynamic TEACH:
Note: TEACH Selection must be programmed to dYn tcH.
1. Enter Adjust Mode.
Method
Action
Result
SET Button 8
Set Mode switch to ADJ
Display: Red - Signal Level; Green Threshold
Remote Input 9
No action required; sensor is ready for
Dynamic TEACH method
2. Enter Dynamic TEACH.
Method
Action
Result
SET Button
Click the SET rocker button
Display: Flashes "dYn tch" then holds
on "1234 dYn"
Remote Input
Single-pulse remote input
T
3. Present ON and OFF Conditions.
Method
Action
Result
SET Button
Present ON and OFF conditions
Display: Red - Signal Level; Green Threshold
8 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
9 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
18
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Method
Action
Result
Remote Input
Present ON and OFF conditions
4. Exit Dynamic TEACH.
Method
Action
Result
SET Button
Click the SET rocker button
TEACH Accepted
Displays alternate "PASS" with %
Minimum Difference 10, Sensor returns
to Adjust mode
Remote Input
Single-pulse remote input
T
TEACH Not Accepted
Displays alternate "FAIL" with %
Minimum Difference 10, Sensor returns
to Adjust mode
5. Return to RUN Mode.
Method
Action
Result
SET Button
Move Mode switch to RUN
Display: Red - Signal Level; Green Threshold
Remote Input
No action required; sensor returns to
RUN mode automatically
3.5.3 Window SET
•
•
•
•
•
Sets window thresholds that extend a programmable % offset above and below the presented condition
All other conditions (lighter or darker) cause the output to change state
Sensing window center can be adjusted using "+" and "-" rocker button (Manual Adjust)
Recommended for applications where a product may not always appear in the same place, or when other signals
may appear
See Program Mode for programming the Offset Percent setting
A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and
below the presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside
the window, and the Output OFF conditions outside the window.
Figure 8. Window SET (Light Operate shown)
Sensing window
center adjusted by
Manual Adjust
Output OFF
Darkest
(no signal)
Output ON
Condition
Presented
Sensor positions
window thresholds
a programmable %
offset from the
presented condition
Output OFF
Most Light
(saturated
signal)
The Output ON and OFF conditions can be reversed by using the LO/DO (Light Operate/ Dark Operate) switch or through
the program interface for the dual output model.
10 See Troubleshooting on p. 25 for more explanation of the % Minimum Difference displayed after the Dynamic TEACH method.
www.bannerengineering.com - Tel: + 1 888 373 6767
19
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Window SET and Manual Adjust
Moves sensing window center value up or down to make adjustments
•
•
•
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
◦ GREEN display shows the sensing window center value
◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Window SET:
Note: TEACH Selection must be programmed to wind SEt.
1. Enter Adjust Mode
Method
Action
Result
SET Button 11
Set Mode switch to ADJ
Display: Red - Signal Level; Green Threshold
Remote Input 12
No action required; sensor is ready for
Window SET method
2. SET Sensing Condition
Method
Action
Result
SET Button
•
•
Present sensing condition
Click the SET rocker button
Remote Input
•
•
Present sensing condition
Single-pulse the remote input
Threshold Condition Accepted
Displays read "wInd SEt" then
alternate "PASS" with % Offset 13;
Sensor returns to Adjust mode
T
Threshold Condition Not Accepted
Displays read "wInd SEt" then
alternate "FAIL" with minimum %
Offset 13 for sensing condition; Sensor
returns to Adjust mode
3. Return to RUN Mode
Method
Action
Result
SET Button
Move Mode switch to Run
Remote Input
No action required; sensor returns to
Run mode automatically
Display: Red - Signal Level; Green Window Center (see Figure 9 on p.
21 for instructions on how to display
upper and lower thresholds)
11 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
12 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
13 See Troubleshooting on p. 25 for more explanation of the % Offset displayed after the Window SET method
20
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Figure 9. Upper and Lower Thresholds
Window SET (during RUN mode)
Upon sensor power-up, Window Center is displayed
Upper
Threshold
Displayed
Lower
Threshold
Displayed
Window
Center
Displayed
3.5.4 Light SET
•
•
•
•
Sets a threshold a programmable % offset below the presented condition
Changes output state on any condition darker than the threshold condition
Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
Recommended for applications where only one condition is known, for example a stable light background with
varying darker targets
• See Program Mode for programming the Offset Percent setting
A single sensing condition is presented, and the sensor positions a threshold a programmable % offset below the presented
condition. When a condition darker than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO
setting.
Figure 10. Light SET (Light Operate shown)
Threshold position
adjusted by
Manual Adjust
Sensor positions
threshold a programmable
% offset below the
presented condition
Output OFF
Darkest
(no signal)
Output ON
Condition
Presented
Most Light
(saturated
signal)
Light SET and Manual Adjust
Moves switching threshold value up or down to make adjustments
•
•
•
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
◦ GREEN display shows the switching threshold value
◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Light SET:
Note: TEACH Selection must be programmed to Lt SEt.
1. Enter Adjust Mode
www.bannerengineering.com - Tel: + 1 888 373 6767
21
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Method
Action
Result
SET Button 14
Set Mode switch to ADJ
Display: Red - Signal Level; Green Threshold
Remote Input 15
No action is required; sensor is ready for
Light SET method
2. SET Sensing Condition
Method
Action
Result
SET Button
•
•
Present sensing condition
Click the SET rocker button
Remote Input
•
•
Present sensing condition
Single-pulse the remote input
Threshold Condition Accepted
Displays read "Lt SEt" then alternate
"PASS" with % Offset 16; Sensor
returns to Adjust mode
T
Threshold Condition Not Accepted
Displays read "Lt SEt" then alternate
"FAIL" with minimum % Offset 16 for
sensing condition; Sensor returns to
Adjust mode
3. Return to RUN Mode
Method
Action
Result
SET Button
Move Mode switch to RUN
Display: Red - Signal Level; Green Threshold
Remote Input
No action required; sensor returns to
RUN mode automatically
3.5.5 Dark SET
•
•
•
•
•
Sets a threshold a programmable % offset above the presented condition
Any condition lighter than the threshold condition causes the output to change state
Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
Recommended for applications where only one condition is known, for example a stable dark background with
varying lighter targets
See Program Mode for programming the Offset Percent setting
Note: Offset Percent MUST be programmed to Minimum Offset to accept conditions of no signal (0
counts).
A single sensing condition is presented, and the sensor positions a threshold a programmable % offset above the presented
condition. When a condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO
setting.
14 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
15 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
16 See Troubleshooting on p. 25 for more explanation of the % Offset displayed after the Light SET method
22
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Figure 11. Dark SET (Light Operate shown)
Threshold position
adjusted by
Manual Adjust
Sensor positions
threshold a programmable
% offset above the
presented condition
Output OFF
Darkest
(no signal)
Output ON
Condition
Presented
Most Light
(saturated
signal)
Dark SET and Manual Adjust
Moves switching threshold value up or down to make adjustments
•
•
•
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
◦ GREEN display shows the switching threshold value
◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Dark SET:
Note: TEACH Selection must be programmed to dr SEt.
1. Enter Adjust Mode.
Method
Action
Result
SET Button 17
Set Mode switch to ADJ
Display: Red - Signal Level; Green Threshold
Remote Input 18
No action required; sensor is ready for
Dark SET method
2. SET Sensing Condition.
Method
Action
Result
SET Button
•
•
Present sensing condition
Click the SET rocker button
Remote Input
•
•
Present sensing condition
Single-pulse the remote input
Threshold Condition Accepted
Displays read "dr SEt" then alternate
"PASS" with % Offset 19; Sensor
returns to Adjust mode
T
Threshold Condition Not Accepted
Displays read "dr SEt" then alternate
"FAIL" with minimum % Offset 19 for
sensing condition; Sensor returns to
Adjust mode
17 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
18 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
19 See Troubleshooting on p. 25 for more explanation of the % Offset displayed after the Dark SET method
www.bannerengineering.com - Tel: + 1 888 373 6767
23
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
3. Return to RUN Mode.
Method
Action
Result
SET Button
Move Mode switch to RUN
Display: Red - Signal Level; Green Threshold
Remote Input
No action required; sensor returns to
RUN mode automatically
3.5.6 Calibration SET
• Sets a threshold exactly at the presented condition
• Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
A single sensing condition is presented, and the sensor positions a threshold exactly at the presented condition. When a
condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting.
Figure 12. Calibration SET (Light Operate shown)
Threshold position
adjusted by
Manual Adjust
Sensor positions
threshold exactly at
the presented condition
Output OFF
Darkest
(no signal)
Output ON
Condition
Presented
Most Light
(saturated
signal)
Calibration SET and Manual Adjust
Moves switching threshold value up or down to make adjustments
•
•
•
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
◦ GREEN display shows the switching threshold value
◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Auto Thresholding is automatically disabled in Calibration SET
Follow these steps to perform a Calibration SET:
Note: TEACH Selection must be programmed to CAL SEt.
1. Enter Adjust Mode
Method
Action
SET Button 20
Remote Input 21
•
Result
Set Mode switch to ADJ
No action required; sensor is ready for
Calibration SET method
2. SET Sensing Condition
20 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
21 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
24
www.bannerengineering.com - Tel: + 1 888 373 6767
Display: Red - Signal Level; Green Threshold
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Method
Action
Result
SET Button
•
•
Present sensing condition
Click the SET rocker button
Remote Input
•
•
Present sensing condition
Single-pulse the remote input
Threshold Condition Accepted
Displays read "cAL SEt" then flashes
"PASS"; Sensor returns to Adjust mode
T
Threshold Condition Unacceptable
Displays read "cAL SEt" then flashes
"FAIL"; Sensor returns to Adjust mode
3. Return to RUN Mode
Method
Action
Result
SET Button
Move Mode switch to RUN
Display: Red - Signal Level; Green Threshold
Remote Input
No action required; sensor returns to
RUN mode automatically
3.6 Troubleshooting
3.6.1 Manual Adjustments Disabled
Manual adjustments are disabled when Auto Thresholds are ON. If a manual adjustment is attempted while Auto Thresholds
are ON, the Green display will flash
.
3.6.2 Percent Minimum Difference after TEACH
The Two-Point and Dynamic TEACH methods will flash a % minimum difference on the displays after a PASS or FAIL.
Value
PASS/FAIL
Description
0 to 99%
FAIL
The difference of the taught conditions does not meet the required minimum
100 to 300%
PASS
The difference of the taught conditions just meets/exceeds the required minimum, minor
sensing variables may affect sensing reliability
300 to 600%
PASS
The difference of the taught conditions sufficiently exceeds the required minimum, minor
sensing variables will not affect sensing reliability
600% +
PASS
The difference of the taught conditions greatly exceeds the required minimum, very
stable operation
3.6.3 Percent Offset after SET
The Window, Dark, and Light SET methods will flash a % offset on the displays after a PASS or FAIL.
SET Result
% Offset Meaning
PASS (with % Offset)
Displays the % offset used for the SET method
FAIL (with % Offset)
Displays the minimum required % offset necessary to PASS the SET method
FAIL (without % Offset)
Presented condition cannot be used for the SET method
www.bannerengineering.com - Tel: + 1 888 373 6767
25
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
3.6.4 Threshold Alert or Threshold Error
Severe contamination/changes in the taught condition can prevent the Auto Thresholds algorithm from optimizing the
threshold(s).
State
Display
Description
Corrective Action
Threshold Alert
Alternates
The threshold(s) cannot be
optimized, but the sensor's output
will still continue to function
Cleaning/correcting the sensing
environment and/or a re-teach of the
sensor is highly recommended
The threshold(s) cannot be
optimized, and the sensor's output
will stop functioning
Cleaning/correcting the sensing
environment and/or a re-teach of the
sensor is required
and
Threshold Error
26
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
4 Specifications
Sensing Beam
DF-G3: Visible red, 635 nm
DF-G3IR: Infrared, 850 nm
DF-G3LIR: Long infrared, 1450 nm
Supply Voltage
10 V DC to 30 V DC Class 2 (10% maximum ripple)
Power and Current Consumption (exclusive of load)
Standard display mode: 840 mW, Current consumption < 35 mA at 24 V DC
ECO display mode: 672 mW, Current consumption < 28 mA at 24 V DC
Supply Protection Circuitry
Protected against reverse polarity, overvoltage, and transient voltages
Delay at Power Up
500 milliseconds maximum; outputs do not conduct during this time
Output Configuration
1 or 2 NPN or PNP outputs, depending on model
Output Rating
100 mA maximum combined load (derate 1 mA per °C above 30 °C)
OFF-state leakage current: < 5 µA at 30 V DC;
ON-state saturation voltage: NPN: < 1.5 V; PNP: < 2 V
Output Protection
Protected against output short-circuit, continuous overload, transient overvoltages, and false pulse on power-up
Response Speed and Features
Description
Response
Speed
Repetition
Period
Repeatability
High Speed
500 µs
100 µs
Fast
1000 µs
100 µs
2 ms
100 µs
Long Range
8 ms
100 µs
180 µs
Yes
Yes
1950 mm
3900 mm
Extra Long Range
24 ms
100 µs
180 µs
Yes
Yes
3000 mm
6000 mm
Standard
Cross-Talk
Avoidance
Energy Efficient Light
Resistance
Maximum
Range, Red 22
Maximum
Range, IR850 23
100 µs
No
No
1200 mm
2400 mm
150 µs
Yes
No
1500 mm
3000 mm
180 µs
Yes
Yes
1500 mm
3000 mm
Indicators
Red 4-digit Display: Signal Level
Green 4-digit Display: Threshold
(In Program Mode, Red and Green displays are used for programming menus)
Yellow LED: Output conducting
Operating Conditions
Temperature: –10 °C to +55 °C (+14 °F to +131 °F)
Storage Temperature: –20 °C to +85 °C (–4 °F to +185 °F)
Humidity: 50% at +50 °C maximum relative humidity (non-condensing)
Environmental Rating
IP50, NEMA 1
Connections
PVC-jacketed 2 m or 9 m (6.5 ft or 30 ft) 4-wire or 5-wire integral cable; or integral 4-pin or 5-pin M8 quick disconnect; or 150 mm (6 in) cable with a 4pin or 5-pin M8 quick disconnect; or 150 mm (6 in) cable with a 4-pin or 5-pin M12 quick disconnect
For Q3 or Q7 5-pin models, either a 5-pin M8 or a 6-pin M8 mating cordset may be used
Construction
Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear polycarbonate cover
22 Excess gain = 1 (high sensitivity), opposed mode sensing. PIT46U plastic fiber used for visible LED models.
23 Excess gain = 1 (high sensitivity), opposed mode sensing. IT.83.3ST5M6 glass fiber used for IR models.
www.bannerengineering.com - Tel: + 1 888 373 6767
27
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Adjustments
3-way RUN/PRG/ADJ Mode Switch
2-way LO/DO Switch or CH1/CH2 Switch
3-way +/SET/- Rocker Button
•
Expert-style teaching (Two-Point and Dynamic TEACH, Light/Dark/Window/Calibration SET)
•
Manually adjust sensitivity (from "+" and "-" rocker button only)
•
Output Selection, TEACH Selection, Response Speed, Offset Percent, Auto Thresholds, Delays/Timers, Sensitivity Selection, Input Selection,
Display Readout, Gain Selection, Factory Defaults (from top panel)
•
Top panel interface lockout (from remote input only)
Factory Default Settings: (Single Output Model)
Setting
Threshold
Factory Default
5024
TEACH Selection
Two-Point TEACH
Output Response Time
Standard: 2000 µs
Offset Percent
10%
Auto Thresholds
OFF
OFF Delay
0 (Disabled)
OFF One-Shot
0 (Disabled)
ON Delay
0 (Disabled)
ON One-Shot
0 (Disabled)
Display Readout
Numeric, ECO disabled, Normal Orientation
Gain Selection
Auto Gain
Factory Default Settings: (Dual Output Model)
Setting
Factory Default
Output
Lo
Threshold
5024
TEACH Selection
Two-Point TEACH
Output Response Time
Standard: 2000 µs
Offset Percent
10%
Auto Thresholds
OFF
OFF Delay
0 (Disabled)
OFF One-Shot
0 (Disabled)
ON Delay
0 (Disabled)
ON One-Shot
0 (Disabled)
Display Readout
Numeric, ECO disabled, Normal Orientation
Sensitivity Selection
Std
Gain Selection
Auto Gain
Required Overcurrent Protection
WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical
codes and regulations.
Overcurrent protection is required to be provided by end product application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
28
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20
5.0
22
3.0
24
2.0
26
1.0
28
0.8
30
0.5
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Certifications
Industrial
Control
Equipment
3TJJ
Class 2 power
4.1 Excess Gain Curves
Figure 13. Diffuse—PBT16U
Figure 14. Diffuse—PBT26U
100000
10000
24mS
24mS
8mS
8mS
10000
1&2mS
1&2mS
1000
500uS
Excess Gain
Excess Gain
500uS
100
10
1000
100
10
1
1
0.1
1
10
100
0.1
1000
1
Distance (mm)
10
100
Figure 15. Diffuse—PBT46U
Figure 16. Diffuse—PBT66U
1000000
10000000
24mS
100000
24mS
1000000
8mS
8mS
1&2mS
1&2mS
100000
500uS
Excess Gain
10000
Excess Gain
1000
Distance (mm)
1000
500uS
10000
1000
100
100
10
10
1
0.1
1
10
100
1000
10000
1
0.1
1
Distance (mm)
10
100
1000
10000
Distance (mm)
www.bannerengineering.com - Tel: + 1 888 373 6767
29
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Figure 17. Opposed Mode—PIT16U
Figure 18. Opposed Mode—PIT26U
1000000
100000
24mS
8mS
1&2mS
1&2mS
10000
500uS
Excess Gain
Excess Gain
24mS
100000
8mS
10000
1000
100
500uS
1000
100
10
10
1
1
1
10
100
1000
1
10
100
Distance (mm)
1000
Figure 19. Opposed Mode—PIT46U
Figure 20. Opposed Mode—PIT66U
10000000
10000000
24mS
1000000
24mS
1000000
8mS
8mS
1&2mS
100000
1&2mS
100000
500uS
Excess Gain
Excess Gain
10000
Distance (mm)
10000
1000
500uS
10000
1000
100
100
10
10
1
1
1
10
100
1000
1
10000
10
100
Distance (mm)
1000
10000
Distance (mm)
Note: The length of the fiber optics limits the range
for the 8 and 24 ms response speeds.
Figure 21. Diffuse—IR850
Figure 22. Opposed Mode—IR850
100000
100000
24mS
24mS
8mS
8mS
10000
1&2mS
1&2mS
500uS
Excess Gain
Excess Gain
10000
1000
100
10
500uS
1000
100
10
1
1
1
10
100
1000
10000
10
100
Distance (mm)
Note: BTC1.13.4ST5M6 glass fiber used for
diffuse mode
30
1000
Distance (mm)
Note: IT.83.3ST5M6 glass fiber used for opposed
mode
www.bannerengineering.com - Tel: + 1 888 373 6767
10000
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Figure 23. Diffuse—LIR1450
Figure 24. Opposed Mode—LIR1450
1000
1000
24mS
24mS
8mS
8mS
2mS
1mS
100
Excess Gain
Excess Gain
2mS
500uS
10
1mS
100
500uS
10
1
1
1
10
100
1000
10
100
Distance (mm)
1000
Distance (mm)
4.2 Beam Patterns
Figure 25. Diffuse—PBT16U
Figure 26. Diffuse—PBT26U
8
4
100
8mS
80
1&2mS
60
500uS
Beam Width (mm)
Beam Width (mm)
6
24mS
2
0
-2
-4
-6
24mS
8mS
1&2mS
500uS
40
20
0
-20
-40
-60
-80
-8
-100
0
20
40
60
80
100
0
50
100
Distance (mm)
Figure 27. Diffuse—PBT46U
200
250
300
Figure 28. Diffuse—PBT66U
24mS
250.0
8mS
1&2mS
150.0
24mS
300
8mS
200.0
1&2mS
200
500uS
500uS
100.0
Beam Width (mm)
Beam Width (mm)
150
Distance (mm)
50.0
0.0
-50.0
-100.0
-150.0
100
0
-100
-200
-200.0
-250.0
0
200
400
600
800
1000
1200
-300
0
500
Distance (mm)
1000
1500
2000
2500
Distance (mm)
www.bannerengineering.com - Tel: + 1 888 373 6767
31
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Figure 29. Opposed Mode—PIT16U
100
24mS
80
8mS
1&2mS
60
500uS
400
24mS
300
8mS
1&2mS
40
Beam Width (mm)
Beam Width (mm)
Figure 30. Opposed Mode—PIT26U
20
0
-20
-40
-60
200
500uS
100
0
-100
-200
-300
-80
-100
-400
0
50
100
150
200
250
300
0
100
200
300
Figure 31. Opposed Mode—PIT46U
8mS
1500
1&2mS
500uS
Beam Width (mm)
Beam Width (mm)
1000
500
0
-500
-1000
-1500
700
800
2500
24mS
2000
8mS
1500
1&2mS
3500
4000
500uS
1000
500
0
-500
-1000
-1500
-2500
0
500
1000
1500
2000
2500
3000
0
3500
500
1000
1500
2000
2500
3000
Distance (mm)
Distance (mm)
Figure 33. Diffuse—IR850
Figure 34. Opposed Mode—IR850
300.0
24mS
8mS
2/1mS
0.5mS
2000
24mS
8mS
2/1mS
0.5mS
200.0
1500
1000
100.0
Beam Width (mm)
Beam Width (mm)
600
-2000
-2000
0.0
-100.0
-200.0
500
0.0
-500
-1000
-1500
-300.0
-2000
0
500
1000
1500
2000
2500
0
1000
Distance (mm)
2000
3000
4000
5000
6000
Distance (mm)
Note: BTC1.13.4ST5M6 glass fiber used for
diffuse mode
32
500
Figure 32. Opposed Mode—PIT66U
24mS
2000
400
Distance (mm)
Distance (mm)
Note: IT.83.3ST5M6 glass fiber used for opposed
mode
www.bannerengineering.com - Tel: + 1 888 373 6767
7000
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
Figure 35. Diffuse—LIR1450
Figure 36. Opposed Mode—LIR1450
24mS
8mS
2/1mS
0.5mS
80
60
300
200
Beam Width (mm)
40
Beam Width (mm)
24mS
8mS
2/1mS
0.5mS
400
20
0
-20
-40
-60
100
0
-100
-200
-300
-80
-400
0
50
100
150
200
250
300
350
0
200
Distance (mm)
400
600
800
1000
Distance (mm)
4.3 Dimensions
www.bannerengineering.com - Tel: + 1 888 373 6767
33
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
5 Accessories
SA-DIN-CLAMP
•
Pair of metal DIN rail end stops; slide onto DIN rail at either
side of the sensor stack
•
Combination (#2 Phillips, #8 standard slotted) set screw
DIN-35-..
35 mm DIN Rail
Model
Length
DIN-35-70
70
DIN-35-105
105
DIN-35-140
140
DIN-35-180
180
DIN-35-220
220
L
35
L = 70, 105 or 140 mm
9.1 mm
(0.63")
Hole center spacing: 35.1
Hole size: 25.4 x 5.3
9.1 mm
(0.36")
45.0 mm
(1.77")
SA-DIN-BRACKET
•
Plastic bracket with
mounting screws
10
SA-DIN-BRACKET-10
•
Package of 10 plastic
brackets with mounting
screws
10
35
35
Hole center spacing: A = 16, B = 25.4, C = 15.2
Hole center spacing: A = 16, B = 25.4, C = 15.2
Hole size: A = ø 3.2, B = ø 3.3, C = ø 4.4
Hole size: A = ø 3.2, B = ø 3.3, C = ø 4.4
5.1 Quick-Disconnect Cordsets—Single Output Models
All measurements are listed in millimeters, unless noted otherwise.
4-Pin Threaded M12 Cordsets—Single Ended
Model
Length
MQDC-406
2 m (6.56 ft)
MQDC-415
5 m (16.4 ft)
MQDC-430
9 m (29.5 ft)
MQDC-450
15 m (49.2 ft)
MQDC-406RA
2 m (6.56 ft)
MQDC-415RA
5 m (16.4 ft)
MQDC-430RA
9 m (29.5 ft)
MQDC-450RA
34
15 m (49.2 ft)
Style
Dimensions
Pinout (Female)
44 Typ.
1
Straight
M12 x 1
ø 14.5
2
3
4
1 = Brown
2 = White
32 Typ.
[1.26"]
2
30 Typ.
[1.18"]
Right-Angle
M12 x 1
ø 14.5 [0.57"]
www.bannerengineering.com - Tel: + 1 888 373 6767
1
3 = Blue
3
4
4 = Black
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
4-Pin Threaded M8 Cordsets—Single Ended
Model
Length
Style
PKG4M-2
2.04 m (6.68
ft)
PKG4M-5
5 m (16.4 ft)
PKG4M-9
9.04 m (29.6
ft)
PKW4M-2
2 m (6.56 ft)
PKW4M-5
5 m (16.4 ft)
Dimensions
35 Typ.
Straight
4
ø 9.5
2
1
3
M8 x 1
28 Typ.
20 Typ.
Right Angle
PKW4M-9
Pinout (Female)
9 m (29.5 ft)
4
2
3
1
1 = Brown
2 = White
3 = Blue
4 = Black
M8 x 1
ø 9.5
4-Pin Snap-on M8 Cordsets—Single Ended
Model
Length
Style
PKG4-2
2.03 m (6.66
ft)
PKG4-5
5.03 m (16.5
ft)
PKG4-10
10 m (32.9 ft)
PKW4Z-2
2 m (6.56 ft)
Dimensions
Pinout (Female)
32 Typ.
4
Straight
2
1
3
ø 9.0
1 = Brown
4
29 Typ.
3
Right-Angle
PKW4Z-5
2
2 = White
1
4 = Black
3 = Blue
15 Typ.
5 m (16.4 ft)
ø 10.9
5.2 Quick-Disconnect Cordsets—Dual Output Models
5-Pin Threaded M12 Cordsets—Single Ended
Model
MQDC1-501.5
Length
Style
Dimensions
0.5 m (1.5 ft)
MQDC1-506
2 m (6.5 ft)
MQDC1-515
5 m (16.4 ft)
1
44 Typ.
4
Straight
MQDC1-530
Pinout (Female)
9 m (29.5 ft)
M12 x 1
ø 14.5
www.bannerengineering.com - Tel: + 1 888 373 6767
2
3
5
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
35
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
5-Pin Threaded M12 Cordsets—Single Ended
Model
Length
MQDC1-506RA
2 m (6.5 ft)
MQDC1-515RA
5 m (16.4 ft)
Style
Dimensions
32 Typ.
[1.26"]
30 Typ.
[1.18"]
Right-Angle
MQDC1-530RA
Pinout (Female)
9 m (29.5 ft)
M12 x 1
ø 14.5 [0.57"]
5-Pin Threaded M8 Cordsets—Single Ended
Model
Length
PKG5M-2
2 m (6.56 ft)
PKG5M-5
5 m (16.4 ft)
Style
Dimensions
35 Typ.
Straight
PKG5M-9
9 m (29.5 ft)
PKW5M-2
2 m (6.56 ft)
PKW5M-5
5 m (16.4 ft)
ø 9.5
M8 x 1
4
5
1
3
6
2
28 Typ.
9 m (29.5 ft)
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
6 = N.C.
20 Typ.
Right Angle
PKW5M-9
Pinout (Female)
M8 x 1
ø 9.5
6-Pin Snap-on M8 Cordsets—Single Ended
Model
Length
PKG6Z-2
2 m (6.56 ft)
PKG6Z-9
9 m (29.53 ft)
Style
Dimensions
Pinout (Female)
32 Typ.
Straight
ø 9.0
4
5
1
3
6
PKW6Z-2
2 m (6.56 ft)
PKW6Z-9
9 m (29.53 ft)
2
29 Typ.
Right-angle
15 Typ.
ø 10.9
36
www.bannerengineering.com - Tel: + 1 888 373 6767
1 - brown
2 = White
3 = Blue
4 = Black
5 = Gray
6 = Pink
DF-G3 Long Range Expert™ Dual Display Fiber Amplifier
5.3 Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will
repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This
warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF
DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE
LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER
ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product
previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection
applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by
Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product
specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most
recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.
www.bannerengineering.com - Tel: + 1 888 373 6767
37