DF-G2-KD-Q5

DF-G2-KD-Q5

  • 厂商:

    BANNER

  • 封装:

    -

  • 描述:

    DF-G2 RED BEAM HIGH SPEED DUAL D

  • 数据手册
  • 价格&库存
DF-G2-KD-Q5 数据手册
DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Instruction Manual Original Instructions 193602 Rev. D 20 March 2019 © Banner Engineering Corp. All rights reserved 193602 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Contents 1 Product Description .........................................................................................................................................................3 1.1 Models ............................................................................................................................................................................................ 3 1.2 Overview ......................................................................................................................................................................................... 3 1.3 Top Panel Interface .........................................................................................................................................................................4 2 Installation Instructions ...................................................................................................................................................5 2.1 Mounting Instructions ..................................................................................................................................................................... 5 2.2 Installing the Fibers .........................................................................................................................................................................5 2.3 Fiber Adapters ................................................................................................................................................................................ 6 2.4 Wiring Diagrams ..............................................................................................................................................................................6 3 Operating Instructions .................................................................................................................................................... 7 3.1 Run Mode ....................................................................................................................................................................................... 7 3.2 Program Mode ................................................................................................................................................................................ 7 3.2.1 Output Selection ..................................................................................................................................................................... 9 3.2.2 TEACH Selection .....................................................................................................................................................................9 3.2.3 Response Speeds ................................................................................................................................................................. 10 3.2.4 Offset Percent ....................................................................................................................................................................... 10 3.2.5 Auto Thresholds .................................................................................................................................................................... 10 3.2.6 Delays/Timers ........................................................................................................................................................................11 3.2.7 Sensitivity Selection .............................................................................................................................................................. 11 3.2.8 Display Readout .................................................................................................................................................................... 11 3.2.9 Gain Selection ....................................................................................................................................................................... 11 3.2.10 Factory Defaults .................................................................................................................................................................. 11 3.3 Remote Input ................................................................................................................................................................................ 12 3.4 Sync Master/Slave ........................................................................................................................................................................ 12 3.5 Adjust Mode ..................................................................................................................................................................................12 3.5.1 TEACH Procedures ............................................................................................................................................................... 13 3.5.2 Troubleshooting .................................................................................................................................................................... 22 4 IO-Link Interface ............................................................................................................................................................ 24 ............................................................................................................................................................... 25 5 Specifications 5.1 Excess Gain Curves ......................................................................................................................................................................26 5.2 Beam Patterns .............................................................................................................................................................................. 28 5.3 Dimensions .................................................................................................................................................................................... 30 6 Accessories .................................................................................................................................................................. 31 6.1 Quick-Disconnect Cordsets ..........................................................................................................................................................31 7 Banner Engineering Corp. Limited Warranty ................................................................................................................ 33 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 1 Product Description Advanced Sensor with Dual Discrete Outputs and IO-Link Communication for Use with Plastic and Glass Fiber Optic Assemblies • • • • • • • • • • • • Response speeds of: 50 µs, 250 µs, 500 µs, 1000 µs and 2000 µs allow for optimization for fast responses, long distance applications, or noisy environments Outstanding color contrast sensitivity; detects 32 levels of gray scale from black to white Visible red and IR beam color models available Easy to read dual digital displays show both signal level and threshold simultaneously Lever action fiber clamp provides stable, reliable, and trouble-free fiber clamping Simple user interface ensures easy sensor set-up and programming through displays and switches/buttons or remote input teach wire Expert TEACH and SET methods ensure optimal gain and threshold for all applications, especially for high speed or low contrast applications User has full control over all operating parameters: threshold, Light Operate or Dark Operate, output timing functions, gain level, and response speed Thermally stable electronics shortens start-up time and maintains signal stability during operation ECO (economy) display mode reduces amplifier power consumption by 25% Cross talk avoidance algorithm allows two sensors to operate in close proximity for many applications Sleek 10 mm wide housing mounts to 35 mm DIN rail WARNING: • Do not use this device for personnel protection • Using this device for personnel protection could result in serious injury or death. • This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A device failure or malfunction can cause either an energized (on) or de-energized (off) output condition. 1.1 Models Model DF-G2-KD-2M Sensing Beam Color Reference Sensing Range1 Channel 1 Channel 2 Connector2 Visible Red 1100 mm Infrared 2100 mm IO-Link, push/pull output PNP only output, or input 2 m (6.5 ft) cable, 4wire DF-G2IR-KD-2M 1.2 Overview The DF-G2 is an easy-to-use, DIN-rail-mountable fiber optic sensor with best in class response speed and repeatability. It provides high-performance sensing in high speed or low contrast applications where fast response time is required. The sensor’s compact housing has dual digital displays (Red/Green) and a bright output LED for easy programming and status monitoring during operation. The sensor features a push-pull primary output which supports IO-link communication, and a multi-function secondary independent PNP output which can be configured as an input for advanced sensor configuration and remote teach. 1 Excess gain = 1, Long Range response speed, opposed mode sensing. PIT46U plastic fiber used for visible LED models, IT.83.3ST5M6 glass fiber used for IR model 2 Connector options: • A model with a QD connector requires a mating cordset • For 150 mm (6 in) PVC, M8 Pico QD connector, 4-pin change the suffix 2M to Q3 in the 2 m model number (example, DF-G2-KD-Q3) • For 150 mm (6 in) PVC, M12 Euro QD connector, 4-pin change the suffix 2M to Q5 in the 2 m model number (example, DF-G2-KD-Q5) • For integral M8 Pico QD connector, 4-pin change the suffix 2M to Q7 in the 2 m model number (example, DF-G2-KD-Q7) www.bannerengineering.com - Tel: + 1 888 373 6767 3 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link The DF-G2 features improved temperature compensation compared with previous fiber optic sensors. An accessory clamp is available to secure a bank of connected sensors together on a DIN rail (see Accessories). Figure 1. DF-G2 IO Link Model Features 1. 2. 3. 4. 5. 6. 7. Output LED CH1/CH2 Switch RUN/PRG/ADJ Mode Switch Lever Action Fiber Clamp Red Signal Level Green Threshold +/SET/- Rocker Button 1.3 Top Panel Interface Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ mode switch, CH1/CH2 switch, +/SET/- rocker button, dual red/green digital displays, and output LED. RUN/PRG/ADJ Mode Switch The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode. • RUN mode allows the sensor to operate normally and prevents unintentional programming changes via the +/SET/- rocker button. • PRG mode allows the sensor to be programmed through the display-driven programming menu (see Program Mode). • ADJ mode allows the user to perform Expert TEACH/SET methods and Manual Adjust (see Adjust Mode). CH1/CH2 Switch (Dual Output Mode) The CH1/CH2 switch selects which output's parameters can be accessed and changed in the interface of the display. +/SET/- Rocker Button The +/SET/- rocker button is a 3-way button. The +/- positions are engaged by rocking the button left/ right. The SET position is engaged by clicking down the button while the rocker is in the middle position. All three button positions are used during PRG mode to navigate the display-driven programming menu. During ADJ mode, SET is used to perform TEACH/SET methods and +/- are used to manually adjust the threshold(s). The rocker button is disabled during RUN mode, except when using Window SET. Red/Green Digital Displays During RUN and ADJ modes, the Red display shows the signal level, and the Green display shows the threshold or the total counts. During PRG mode, both displays are used to navigate the display-driven programming menu. Dual Output LEDs The output LEDs provide a visible indication when the associated output is active (conducting). • 1 represents the Channel 1 output • 2 represents the Channel 2 output 4 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 2 Installation Instructions 2.1 Mounting Instructions Mount on a DIN Rail 1. Hook the DIN rail clip on the bottom of the DF-G2 over the edge of the DIN rail (1). 2. Push the DF-G2 up on the DIN rail (1). 3. Pivot the DF-G2 onto the DIN rail, pressing until it snaps into place (2). Mount to the Accessory Bracket (SA-DIN-BRACKET) 1. Position the DF-G2 in the SA-DIN-BRACKET. 2. Insert the supplied M3 screws. 3. Tighten the screws. Remove from a DIN rail 1. Push the DF-G2 up on the DIN rail (1). 2. Pivot the DF-G2 away from the DIN rail and remove it (2). 2.2 Installing the Fibers Follow these steps to install glass or plastic fibers. 1. 2. 3. 4. 5. Open the dust cover. Move the fiber clamp forward to unlock it. Insert the fiber(s) into the fiber port(s) until they stop. Move the fiber clamp backward to lock the fiber(s). Close the dust cover. Move forward to release the fibers Fiber Clamp Fiber Receiver Port Fiber Emitter Port Note: For optimum performance of IR models, if applicable, glass fibers must be used. www.bannerengineering.com - Tel: + 1 888 373 6767 5 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 2.3 Fiber Adapters Note: If a thin fiber with less than 2.2 mm outer diameter is used, install the fiber adapter provided with the fiber assembly to ensure a reliable fit in the fiber holder. Align the fibers to the end of the adaptors. Banner includes the adapters with all fiber assemblies. TO FIBERS TO SENSOR Fiber Outer Diameter (mm) Adapter Color Ø 1.0 Black Ø 1.3 Red Ø 2.2 No adapter needed When connecting coaxial-type fiber assemblies to the amplifier, install the single-core (center) fiber to the Transmitter port, and the multi-core (outer) fiber to the Receiver port. This will result in the most reliable detection. RECEIVER Multi-core fiber Single-core fiber TRANSMITTER 2.4 Wiring Diagrams Key 4 + CH1 Load 3 2 1 PUSH-PULL PUSH-PULL 1 10-30V dc – CH2 4 Figure 2. Channel 1 as a Push-Pull discrete output, Channel 2 as PNP discrete output CH1 10–30 V dc Load – CH2 1 = Brown 2 = White 3 = Blue 3 2 Load + 4 = Black Remote Input Figure 3. Channel 1 as a Push-Pull discrete output, Channel 2 as remote input Note: Open lead wires must be connected to a terminal block. Note: The Channel 2 wire function is user-selectable. The default is independent Light Operate (LO) PNP output. See the Remote Input section for details regarding use as remote input or the Sync Master/Slave section for use as a synchronization output. 6 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 3 Operating Instructions 3.1 Run Mode Run mode allows the sensor to operate normally and prevents unintentional programming changes. The +/SET/- rocker button is disabled during RUN mode, except when using Window SET. 3.2 Program Mode Program (PRG) mode allows the following settings to be programmed in the DF-G2. www.bannerengineering.com - Tel: + 1 888 373 6767 7 8 Menu List Figure 4. CH 1 Program Mode Chart www.bannerengineering.com - Tel: + 1 888 373 6767 Return to Menu List 2000 µS 1000 µS Auto Menu available in Lt, dr or wind set only GAin SEL Click SET to enter choice list to set value Click SET to set value Click SET to set value Click SET to set value Click SET to set value Click SET to set value Click SET setting-specific on display represents a “w” DISPLAY LOOP Click SET to enter choice list (display flips 180˚) DISPLAY LOOP Click SET to enter choice list on display represents a “m” Click SET to select and save a choice in any list Menu not available when in CAL set diSP 1234 to set value diSP rEAd 500 µS high 250 µS SEnS SEL1 50 µS oFF DISPLAY LOOP dLY SEL1 DISPLAY LOOP oFF DISPLAY LOOP Auto thr1 DISPLAY LOOP 10 Pct DISPLAY LOOP OFSt Pct1 32 Fixed Gain Set DISPLAY LOOP Click SET to enter choice list DISPLAY LOOP Click SET to enter choice list 250 us Click SET to enter choice list rESP SPd Click SET to enter choice list 2-pt tch Click SET to enter choice list tch SEL1 Click SET to enter choice list LO Click SET to enter choice list default setting rocker button Out SEL1 To scroll through menu lists: Press “+” or “-” To enter a choice list or to select and save: Click SET To exit a choice list without saving: Press and hold SET for 2 seconds Factory Default Switch Mode to “PRG” Setting Press and hold SET to exit choice list without saving PROGRAM MODE DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link CH 1 Factory Default Settings: Menu List oFF dLY SEL2 oFF SEnS SEL2 high www.bannerengineering.com - Tel: + 1 888 373 6767 DISPLAY LOOP DISPLAY LOOP DISPLAY LOOP Click SET to enter choice list Click SET (+) or (-) to set value (+) or (-) to set value (+) or (-) to set value (+) or (-) to set value Click SET Click SET (+) or (-) to set value (+) or (-) to set value Click SET Click SET Click SET setting-specific on display represents a “m” DISPLAY LOOP Click SET to enter choice list CH 2 Factory Default Settings: If Master (mASt), indicate number of Slaves (1..6) under subsequent “totL SLAV” menu option If Slave (SLVE), indicate its address (Master address is 0) under subsequent “SLAV Addr” menu option on display represents a “w” Return to Menu List Click SET to select and save a choice in any list Not available in CAL Set Click SET to enter choice list Click SET to enter choice list Available in Lt, dr or wind set only Auto thr2 (+) or (-) to set value 10 Pct DISPLAY LOOP OFSt Pct2 DISPLAY LOOP 2-pt tch Click SET to enter choice list tch SEL2 Click SET to enter choice list LO default setting rocker button Out SEL2 To scroll through menu lists: Press “+” or “-” To enter a choice list or to select and save: Click SET To exit a choice list without saving: Press and hold SET for 2 seconds Factory Default Switch Mode to “PRG” Setting Press and hold SET to exit choice list without saving PROGRAM MODE DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Figure 5. CH 2 Program Mode Chart 3.2.1 Output Selection Both CH1 and CH2 can be programmed for either light operate (LO) or dark operate (DO). The Channel 2 menu includes additional options: Health (Health Mode Alarm), Comp (Complementary Programming), Set (sets Channel 2 wire as a remote input), Mast (selects this unit as the master and then allows you to enter the total number of slaves there will be), Slve (selects this unit as a slave and then allows you to enter this slave address), LED off, LED on and Gate. 3.2.2 TEACH Selection The DF-G2 can be programmed for one of the following TEACH/SET methods: • Two-Point TEACH • Dynamic TEACH • Window SET • Light SET • Dark SET • Calibration SET Note: A TEACH Selection must be selected by programming before TEACH/SET methods can be used. 9 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 3.2.3 Response Speeds Description Response Speed Repetition Period Repeatability Cross-Talk Avoidance Energy Efficient Light Resistance Maximum Range, Red3 Maximum Range, IR8504 Fast 50 us 12 us 12 us No No 500 750 Standard 250 us 50 us 50 us Yes No 725 1300 Medium Range 500 us 80 us 80 us Yes No 900 1600 Long Range 1000 us 165 us 165 us Yes No 1100 2100 Long Range (with Immunity) 2000 us 165 us 165 us Yes Yes 1100 2100 3.2.4 Offset Percent The Offset Percent is used during the Window, Light, or Dark SET methods. The threshold(s) are positioned a programmable % offset from the taught condition. The allowable offset percent range varies based on the response speed, teach method and sensitivity settings as shown below: Teach Method Response Speed Sensitivity Offset % Range Window Set, Light Set 50 µs, 250 µs High 2 to 98% Standard 5 to 95% Low 10 to 90% High 1 to 99% Standard 2 to 98% Low 5 to 95% High 2 to 999% Standard 5 to 999% Low 10 to 999% High 1 to 999% Standard 2 to 999% Low 5 to 999% 500 µs, 1000 µs, 2000 µs Dark Set 50 µs, 250 µs 500 µs, 1000 µs, 2000 µs 3.2.5 Auto Thresholds Auto Thresholds can be programmed to be ON/OFF. The Auto Thresholds algorithm continuously tracks slow changes in the taught condition(s), and optimizes the threshold(s) to provide for reliable sensing. For Two-Point and Dynamic TEACH, the algorithm optimizes the threshold to be centered between the light and dark conditions. For Window, Light, and Dark SET, the algorithm optimizes the threshold(s) to maintain the programmed Offset Percent from the taught condition. • After programming Auto Thresholds to ON, it is highly recommended to re-perform the TEACH/SET method • Manual Adjustments are disabled when Auto Thresholds are ON • Auto Thresholds are automatically disabled in Calibration SET (see Calibration SET on page 21) • Severe contamination/changes in the taught condition can prevent the Auto Thresholds algorithm from optimizing the threshold(s). If this occurs, the DF-G2 enters a Threshold Alert or Threshold Error state. See Troubleshooting on page 22 for more explanation. 3 Excess Gain = 1 at High Sensitivity setting; opposed mode sensing using PIT46U plastic fiber 4 Excess Gain = 1 at High Sensitivity setting; opposed mode sensing using IT.83.3ST5M6 glass fiber 10 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 3.2.6 Delays/Timers ON/OFF Delays and ON/OFF One-Shot timers can be programmed independently for both CH1 and CH2 for a time period between between 1 - 9999 ms (a value of 0 disables the delay/timer). Figure 6 on page 11 defines how the delays/timers affect the output behavior. ON Output OFF OFF Delay Some combinations of delays/timers are not allowed. The DF-G2 programming menu automatically disables invalid combinations of delays/timers. The following table shows the allowable combinations of delays/timers: OFF 1-Shot D D D D ON Delay D D ON 1-Shot D D (D = 1 - 9999 ms) Time Figure 6. DF-G2 Delays/Timers OFF Delay OFF One-Shot Timer ON Delay ON One-Shot Timer - OK OK N/A OFF One-Shot Timer OK - N/A N/A ON Delay OK N/A - OK ON One-Shot Timer N/A N/A OK - OFF Delay 3.2.7 Sensitivity Selection The Sensitivity Selection can be programmed independently for CH1 and CH2. Use this setting to increase (lo) or decrease (high) the switch-point hysteresis from the default (std) setting. • high—High sensitivity. Use this setting for low contrast sensing • Std—Standard sensitivity • Lo—Low sensitivity. Use this setting to stabilize the output in high vibration applications 3.2.8 Display Readout The readout of the digital displays can be programmed for the following options: • Signal/Threshold readout - Numeric (1234) or % (123P) • ECO mode - Enabled or Disabled (ECO mode dims the displays to reduce current consumption) ) or Flipped ( ) • Display Orientation - Normal ( 3.2.9 Gain Selection The DF-G2 can operate in Auto Gain mode or the Gain can be fixed to be in Gain . In Auto Gain, the DF-G2 optimizes the gain during a TEACH/SET method for the presented condition(s). While viewing the fixed gains in the Gain Selection choice list, the DF-G2 will automatically switch to the selected gain and display the measured signal on the Red display. This allows for easy and quick evaluation of the fixed gain mode. 3.2.10 Factory Defaults The Factory Defaults menu allows the DF-G2 to be easily restored back to original factory default settings (see Factory Default Settings in Program Mode ). www.bannerengineering.com - Tel: + 1 888 373 6767 11 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 3.3 Remote Input Use the input wire to program the sensor remotely. To program the sensor using the input wire, remote input must be enabled (inPT SEL = SEt). The remote input provides limited programming options (see the figure below). Pulse the remote input according to the figures and the instructions provided in this manual. Note: For NPN models, the remote input pulses are active low as shown in the following figures. For PNP models, the remote input pulses are active high and are inverted from the following figures. REMOTE TEACH Remote Input NOTE: Follow procedure for the selected TEACH/SET method (highlighted in black box) chosen in the TEACH Selection menu 1x Starts Selected Teach Completes Teach 1x 3x Remote Setup REMOTE SETUP 1x 2x Teach Selection 1x Two-Point 2x Dynamic 3x One-Point Window 4x One-Point Light Set 5x One-Point Dark Set 6x CAL Set LO/DO Selection LO DO 1x 2x Button Lock (loc) or Unlock (uloc) 4x 8x Pulse Timing (T) 0.04 seconds < T < 0.8 seconds Timing between Pulse groups > 1 second 1x Button Unlock (uloc) 2x Button Lock (loc) Factory Default Settings Figure 7. Single Output — Remote Input Flowchart 3.4 Sync Master/Slave Up to seven DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link sensors may be used together in a single sensing application. To eliminate crosstalk between the sensors, configure one sensor to be the master and the remaining sensors to be the slaves. In this mode, the sensors alternate taking measurements and the response speed is 2 ms. Note: Note: In this mode, all sensors must either be NPN or PNP output models. 1. 2. 3. 4. 5. Configure the first sensor as the Master (inPt SEL = MAST). In the Master sensor set-up, enter the total number of Slave sensors you will be using (tOtL SLAV = 1 - 6). For each Slave sensor used, configure the input as a Slave (inPt SEL = SLVE). Give each Slave its own identifying address (SLAV Addr = 1 - 6). Connect the Input wires of the Master and all of the Slaves together. Note: Note: Giving two Slave sensors the same address will cause them to fire their emitters at the same time in the firing sequence. 3.5 Adjust Mode Sliding the RUN/PRG/ADJ mode switch to the ADJ position allows the user to perform Expert TEACH/SET methods and Manual Adjustment of the threshold(s). 12 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Note: For the Dual Output models, when teaching CH2, the gain setting will be the same as the gain setting made during the CH1 teach. Reteaching CH1 may invalidate the previous CH2 teach. 3.5.1 TEACH Procedures The instruction manual has detailed instructions for these TEACH modes: • Two-Point TEACH • Dynamic TEACH • Window SET • Light SET • Dark SET • Calibration SET Two-Point TEACH • • Establishes a single switching threshold Threshold can be adjusted by using the "+" and "-" rocker button (Manual Adjust) Two-Point TEACH is used when two conditions can be presented statically to the sensor. The sensor locates a single sensing threshold (the switch point) midway between the two taught conditions, with the Output ON condition on one side, and the Output OFF condition on the other. Darkest Taught Condition Lightest Taught Condition Sensor positions threshold midway between taught conditions Output OFF Darkest (no signal) Output ON Position adjusted by Manual Adjust Most Light (saturated signal) Figure 8. Two-Point TEACH (Light Operate shown) The Output ON and OFF conditions can be reversed by using the LO/DO (Light Operate/ Dark Operate) switch. Two-Point TEACH and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember: Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Two-Point TEACH: Note: TEACH Selection must be programmed to 2Pt tcH. 1. Enter Adjust mode. Method Action Result SET Button 5 Set the Mode switch to ADJ. Display: Red - Signal Level; Green Threshold 5 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds www.bannerengineering.com - Tel: + 1 888 373 6767 13 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Method Action Result Remote Input 6 No action is required; sensor is ready for the Two-Point TEACH method 2. Teach the first condition. Method Action Result SET Button a. Present the first condition. Display: Flashes "2Pt tch" then holds on "1234 2nd" b. Click the SET rocker button. Remote Input a. Present the first condition. T b. Single-pulse the remote input. 3. Teach the second condition. Method Action Result SET Button a. Present the second condition. TEACH Accepted b. Click the SET rocker button. Displays alternate "PASS" and % Minimum Difference7; Sensor returns to Adjust mode Remote Input a. Present the second condition. T b. Single-pulse the remote input. TEACH Not Accepted Displays alternate "FAIL" and % Minimum Difference7; Sensor returns to Adjust mode 4. Return to Run mode. Method Action Result SET Button Move the Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action is required; sensor returns to RUN mode automatically Dynamic TEACH • • • Teaches on-the-fly Establishes a single switching threshold Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust) Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actual sensing conditions, taking multiple samples of the light and dark conditions and automatically setting the threshold at the optimum level. 6 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds 7 See Troubleshooting on page 22 for more explanation of the % Minimum Difference displayed after the Two-Point TEACH method. 14 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Darkest Taught Condition Lightest Taught Condition Sensor positions threshold midway between taught conditions Output OFF Darkest (no signal) Output ON Most Light (saturated signal) Position Figure 9. Dynamic TEACH (Light Operate shown) The output ON and OFF conditions can be reversed using the LO/DO switch. Dynamic TEACH and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember: Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform Dynamic TEACH: Note: TEACH Selection must be programmed to dYn tcH. 1. Enter Adjust Mode. Method Action Result SET Button 8 Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold Remote Input 9 No action required; sensor is ready for Dynamic TEACH method 2. Enter Dynamic TEACH. Method Action Result SET Button Click the SET rocker button Display: Flashes "dYn tch" then holds on "1234 dYn" Remote Input Single-pulse remote input T 3. Present ON and OFF Conditions. Method Action Result SET Button Present ON and OFF conditions Display: Red - Signal Level; Green Threshold Remote Input Present ON and OFF conditions 8 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 9 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds www.bannerengineering.com - Tel: + 1 888 373 6767 15 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 4. Exit Dynamic TEACH. Method Action Result SET Button Click the SET rocker button TEACH Accepted Remote Input Displays alternate "PASS" with % Minimum Difference10, Sensor returns to Adjust mode Single-pulse remote input T TEACH Not Accepted Displays alternate "FAIL" with % Minimum Difference10, Sensor returns to Adjust mode 5. Return to RUN Mode. Method Action Result SET Button Move Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action required; sensor returns to RUN mode automatically Window SET • • • • • Sets window thresholds that extend a programmable % offset above and below the presented condition All other conditions (lighter or darker) cause the output to change state Sensing window center can be adjusted using "+" and "-" rocker button (Manual Adjust) Recommended for applications where a product may not always appear in the same place, or when other signals may appear See Program Mode for programming the Offset Percent setting A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and below the presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside the window, and the Output OFF conditions outside the window. Sensing Window Sensor positions window thresholds a programmable % offset from the presented condition Output OFF Darkest (no signal) Output ON Output OFF Condition Presented Most Light (saturated signal) Figure 10. Window SET (Light Operate shown) Output ON and OFF conditions can be reversed using the LO/DO switch. Window SET and Manual Adjust Moves sensing window center value up or down to make adjustments • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease 10 See Troubleshooting on page 22 for more explanation of the % Minimum Difference displayed after the Dynamic TEACH method. 16 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link • ◦ GREEN display shows the sensing window center value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember: Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Window SET: Note: TEACH Selection must be programmed to wind SEt. 1. Enter Adjust Mode Method Action Result SET Button 11 Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold Remote Input 12 No action required; sensor is ready for Window SET method 2. SET Sensing Condition Method Action Result SET Button • • Present sensing condition Click the SET rocker button Remote Input • • Present sensing condition Single-pulse the remote input Threshold Condition Accepted Displays read "wInd SEt" then alternate "PASS" with % Offset13; Sensor returns to Adjust mode T Threshold Condition Not Accepted Displays read "wInd SEt" then alternate "FAIL" with minimum % Offset13 for sensing condition; Sensor returns to Adjust mode 3. Return to RUN Mode Method Action Result SET Button Move Mode switch to Run Remote Input No action required; sensor returns to Run mode automatically Display: Red - Signal Level; Green Window Center (see Figure 11 on page 18 for instructions on how to display upper and lower thresholds) 11 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 12 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds 13 See Troubleshooting on page 22 for more explanation of the % Offset displayed after the Window SET method www.bannerengineering.com - Tel: + 1 888 373 6767 17 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Window SET (during RUN mode) Upon sensor power-up, Window Center is displayed Upper Threshold Displayed Lower Threshold Displayed Window Center Displayed Figure 11. Upper and Lower Thresholds Light SET • • • • • Sets a threshold a programmable % offset below the presented condition Changes output state on any condition darker than the threshold condition Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust) Recommended for applications where only one condition is known, for example a stable light background with varying darker targets See Program Mode for programming the Offset Percent setting A single sensing condition is presented, and the sensor positions a threshold a programmable % offset below the presented condition. When a condition darker than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting. Threshold Position Sensor positions threshold a programmable % offset below the presented condition Output OFF Darkest (no signal) Output ON Condition Presented Most Light (saturated signal) Figure 12. Light SET (Light Operate shown) Light SET and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember: Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Light SET: Note: TEACH Selection must be programmed to Lt SEt. 1. Enter Adjust Mode 18 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Method Action Result SET Button 14 Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold Remote Input 15 No action is required; sensor is ready for Light SET method 2. SET Sensing Condition Method Action Result SET Button • • Present sensing condition Click the SET rocker button Remote Input • • Present sensing condition Single-pulse the remote input Threshold Condition Accepted Displays read "Lt SEt" then alternate "PASS" with % Offset16; Sensor returns to Adjust mode T Threshold Condition Not Accepted Displays read "Lt SEt" then alternate "FAIL" with minimum % Offset16 for sensing condition; Sensor returns to Adjust mode 3. Return to RUN Mode Method Action Result SET Button Move Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action required; sensor returns to RUN mode automatically Dark SET • • • • • Sets a threshold a programmable % offset above the presented condition Any condition lighter than the threshold condition causes the output to change state Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust) Recommended for applications where only one condition is known, for example a stable dark background with varying lighter targets See Program Mode for programming the Offset Percent setting Note: Offset Percent MUST be programmed to Minimum Offset to accept conditions of no signal (0 counts). A single sensing condition is presented, and the sensor positions a threshold a programmable % offset above the presented condition. When a condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting. 14 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 15 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds 16 See Troubleshooting on page 22 for more explanation of the % Offset displayed after the Light SET method www.bannerengineering.com - Tel: + 1 888 373 6767 19 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Threshold position adjusted by Manual Adjust Sensor positions threshold a programmable % offset above the presented condition Output OFF Darkest (no signal) Output ON Condition Presented Most Light (saturated signal) Figure 13. Dark SET (Light Operate shown) Dark SET and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember: Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Dark SET: Note: TEACH Selection must be programmed to dr SEt. 1. Enter Adjust Mode. Method Action Result SET Button 17 Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold Remote Input 18 No action required; sensor is ready for Dark SET method 2. SET Sensing Condition. Method Action Result SET Button • • Present sensing condition Click the SET rocker button Remote Input • • Present sensing condition Single-pulse the remote input Threshold Condition Accepted Displays read "dr SEt" then alternate "PASS" with % Offset19; Sensor returns to Adjust mode T Threshold Condition Not Accepted Displays read "dr SEt" then alternate "FAIL" with minimum % Offset19 for sensing condition; Sensor returns to Adjust mode 17 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 18 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds 19 See Troubleshooting on page 22 for more explanation of the % Offset displayed after the Dark SET method 20 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 3. Return to RUN Mode. Method Action Result SET Button Move Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action required; sensor returns to RUN mode automatically Calibration SET • • Sets a threshold exactly at the presented condition Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust) A single sensing condition is presented, and the sensor positions a threshold exactly at the presented condition. When a condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting. Threshold position adjusted by Manual Adjust Sensor positions threshold exactly at the presented condition Output OFF Darkest (no signal) Output ON Condition Presented Most Light (saturated signal) Figure 14. Calibration SET (Light Operate shown) Calibration SET and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember: Auto Thresholding is automatically disabled in Calibration SET Follow these steps to perform a Calibration SET: Note: TEACH Selection must be programmed to CAL SEt. 1. Enter Adjust Mode Method Action SET Button 20 Remote Input 21 • Result Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold No action required; sensor is ready for Calibration SET method 2. SET Sensing Condition 20 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 21 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds www.bannerengineering.com - Tel: + 1 888 373 6767 21 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Method Action Result SET Button • • Present sensing condition Click the SET rocker button Remote Input • • Present sensing condition Single-pulse the remote input Threshold Condition Accepted Displays read "cAL SEt" then flashes "PASS"; Sensor returns to Adjust mode T Threshold Condition Unacceptable Displays read "cAL SEt" then flashes "FAIL"; Sensor returns to Adjust mode 3. Return to RUN Mode Method Action Result SET Button Move Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action required; sensor returns to RUN mode automatically 3.5.2 Troubleshooting Manual Adjustments Disabled Manual adjustments are disabled when Auto Thresholds are ON. If a manual adjustment is attempted while Auto Thresholds are ON, the Green display will flash . Percent Minimum Difference after TEACH The Two-Point and Dynamic TEACH methods will flash a % minimum difference on the displays after a PASS or FAIL. Value PASS/FAIL 0 to 99% FAIL The difference of the taught conditions does not meet the required minimum 100 to 300% PASS The difference of the taught conditions just meets/exceeds the required minimum, minor sensing variables may affect sensing reliability 300 to 600% PASS The difference of the taught conditions sufficiently exceeds the required minimum, minor sensing variables will not affect sensing reliability 600% + PASS The difference of the taught conditions greatly exceeds the required minimum, very stable operation Description Percent Offset after SET The Window, Dark, and Light SET methods will flash a % offset on the displays after a PASS or FAIL. SET Result % Offset Meaning PASS (with % Offset) Displays the % offset used for the SET method FAIL (with % Offset) Displays the minimum required % offset necessary to PASS the SET method FAIL (without % Offset) Presented condition cannot be used for the SET method 22 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Threshold Alert or Threshold Error Severe contamination/changes in the taught condition can prevent the Auto Thresholds algorithm from optimizing the threshold(s). State Display Description Corrective Action Threshold Alert Alternates The threshold(s) cannot be optimized, but the sensor's output will still continue to function Cleaning/correcting the sensing environment and/or a re-teach of the sensor is highly recommended The threshold(s) cannot be optimized, and the sensor's output will stop functioning Cleaning/correcting the sensing environment and/or a re-teach of the sensor is required and Threshold Error www.bannerengineering.com - Tel: + 1 888 373 6767 23 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 4 IO-Link Interface IO-Link is a point-to-point communication link between a master device and sensor. Use IO-Link to parameterize sensors and transmit process data automatically. For the latest IO-Link protocol and specifications, see www.io-link.com. Each IO-Link device has an IODD (IO Device Description) file that contains information about the manufacturer, article number, functionality etc. This information can be easily read and processed by the user. Each device can be unambiguously identified via the IODD as well as via an internal device ID. Download the DF-G2's IO-Link IODD package (p/n 18491) from Banner Engineering's website at www.bannerengineering.com. Banner has also developed Add On Instruction (AOI) files to simplify ease-of-use between the DF-G2, multiple third-party vendors' IO-Link masters, and the Logix Designer software package for Rockwell Automation PLCs. Three types of AOI files for Rockwell Allen-Bradley PLCs are listed below. These files and more information can be found at www.bannerengineering.com. Process Data AOIs—These files can be used alone, without the need for any other IO‐Link AOIs. The job of a Process Data AOI is to intelligently parse out the Process Data word(s) in separate pieces of information. All that is required to make use of this AOI is an EtherNet/IP connection to the IO‐Link Master and knowledge of where the Process Data registers are located for each port. Parameter Data AOIs—These files require the use of an associated IO‐Link Master AOI. The job of a Parameter Data AOI, when working in conjunction with the IO‐Link Master AOI, is to provide quasi‐realtime read/write access to all IO‐Link parameter data in the sensor. Each Parameter Data AOI is specific to a given sensor or device. IO‐Link Master AOIs—These files require the use of one or more associated Parameter Data AOIs. The job of an IO‐Link Master AOI is to translate the desired IO‐Link read/write requests, made by the Parameter Data AOI, into the format a specific IO‐Link Master requires. Each IO‐Link Master AOI is customized for a given brand of IO‐Link Master. Add and configure the relevant Banner IO‐Link Master AOI in your ladder logic program first; then add and configure Banner IO‐Link Device AOIs as desired, linking them to the Master AOI as shown in the relevant AOI documentation. 24 www.bannerengineering.com - Tel: + 1 888 373 6767 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 5 Specifications Sensing Beam DF-G2: Visible red, 635 nm DF-G2IR: Infrared, 850 nm IO-Link Interface Supports smart sensor profile: Yes Baud rate: 38400 bps Process data widths: 16 bits IODD files: Provides all programming options of the display, plus additional functionality Supply Voltage 10 V to 30 V dc Class 2 (10% maximum ripple) Power and Current Consumption (exclusive of load) Standard display mode: 960 mW, Current consumption < 40 mA at 24 V dc ECO display mode: 720 mW, Current consumption < 30 mA at 24 V dc Supply Protection Circuitry Protected against reverse polarity and transient overvoltages Delay at Power-Up 500 milliseconds maximum; outputs do not conduct during this time Output Configuration CH1 = IO-Link, Push/pull CH2 = PNP only output or input Output Rating 100 mA maximum load each output (derate 1 mA per °C above 30° C) 100 mA max total load current for sensor OFF-state leakage current: < 5 µA PNP at 30 V dc (N.A. push/pull); ON-state saturation voltage: < 2 V Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Output Protection Protected against output short-circuit, continuous overload, transient overvoltages, and false pulse on power-up Construction Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear polycarbonate cover Connections PVC jacketed 2 m (6.5 ft) 4-wire integral cable; or integral 4-pin M8/ Pico-style quick disconnect; or 150 mm (6 inch) cable with a 4-pin M12/Euro-style quick disconnect; or 150 mm (6 inch) cable with a 4pin M8/Pico-style quick disconnect Adjustments 3-way RUN/PRG/ADJ Mode Switch 2-way CH1/CH2 Switch 3-way +/SET/- Rocker Button • Expert-style teaching (Two-Point and Dynamic TEACH, Light/Dark/Window/Calibration SET) • Manually adjust sensitivity (from "+" and "-" rocker button only) • Response Speed, TEACH Selection, Offset Percent, Auto Thresholds, Delays/Timers, Display Readout, Gain Selection, Factory Defaults (from top panel or remote input) • Top panel interface lockout (from remote input only) Indicators Red 4-digit Display: Signal Level Green 4-digit Display: Threshold (In Program Mode, Red and Green displays are used for programming menus) Amber LED: Output conducting Environmental Rating IEC IP50, NEMA 1 Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 Industrial Control Equipment 30 0.5 3TJJ Operating Conditions Temperature: –10 °C to +55 °C (+14 °F to +131 °F) Storage Temperature: –20 °C to +85 °C (–4 °F to +185 °F) Humidity: 90% at +60 °C maximum relative humidity (noncondensing) Certifications Response Speed Response Speed Repetition Period Repeatability Fast 50 us 12 us Standard 250 us 50 us Description Cross-Talk Avoidance Energy Efficient Light Resistance Maximum Range, Red22 Maximum Range, IR85023 12 us No No 500 750 50 us Yes No 725 1300 Medium Range 500 us 80 us 80 us Yes No 900 1600 Long Range 1000 us 165 us 165 us Yes No 1100 2100 Long Range (with Immunity) 2000 us 165 us 165 us Yes Yes 1100 2100 22 Excess Gain = 1 at High Sensitivity setting; opposed mode sensing using PIT46U plastic fiber 23 Excess Gain = 1 at High Sensitivity setting; opposed mode sensing using IT.83.3ST5M6 glass fiber www.bannerengineering.com - Tel: + 1 888 373 6767 25 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 5.1 Excess Gain Curves The excess gain curves shown are for the standard red LED and IR850 LED emitter models. The data in the charts that is labeled for the Long Range application apply to both the 1000 µs and 2000 µs response speeds. Table 1: 0.25 mm (0.01 in) Diameter Fibers Opposed Mode Diffused Mode 1000 10000 Long Medium Standard Fast Long Medium Standard Fast EXCESS GAIN EXCESS GAIN 1000 100 100 10 10 1 0.1 1 10 1 100 0.1 DISTANCE (mm) 1 10 100 DISTANCE (mm) Figure 15. PIT16U Figure 16. PBT16U Table 2: 0.51 mm (0.02 in) Diameter Fibers Opposed Mode Diffused Mode 10000 100000 Long Medium Standard Fast 1000 EXCESS GAIN EXCESS GAIN 10000 Long Medium Standard Fast 1000 100 100 10 10 1 0.1 1 1 10 100 1000 0.1 DISTANCE (mm) Figure 17. PIT26U 26 1 10 DISTANCE (mm) Figure 18. PBT26U www.bannerengineering.com - Tel: + 1 888 373 6767 100 1000 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Table 3: 1.02 mm (0.04 in) Diameter Fibers Opposed Mode Diffused Mode 1000000 100000 Long Medium Standard Fast 10000 10000 EXCESS GAIN EXCESS GAIN 100000 Long Medium Standard Fast 1000 100 1000 100 10 10 1 1 10 100 1000 10000 DISTANCE (mm) 1 0.1 Figure 19. PIT46U 1 10 100 1000 DISTANCE (mm) Figure 20. PBT46U Table 4: 1.52 mm (0.06 in) Diameter Fibers Opposed Mode Diffused Mode 1000000 100000 Long Medium Standard Fast 10000 10000 EXCESS GAIN EXCESS GAIN 100000 Long Medium Standard Fast 1000 100 1000 100 10 10 1 1 10 100 DISTANCE (mm) Figure 21. PIT66U 1000 10000 1 0.1 1 10 100 1000 DISTANCE (mm) Figure 22. PBT66U www.bannerengineering.com - Tel: + 1 888 373 6767 27 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Table 5: IT.83.3ST5M6 glass fiber used for opposed mode; BTC1.13.4.T5M6 glass fiber used for diffuse mode Opposed Mode Diffused Mode 10000 10000 Long Medium Standard Fast 1000 EXCESS GAIN EXCESS GAIN 1000 100 100 10 1 Long Medium Standard Fast 10 10 100 1000 1 10000 1 10 DISTANCE (mm) 100 1000 DISTANCE (mm) Figure 23. IR850 Figure 24. IR850 5.2 Beam Patterns The beam patterns shown are for the standard red LED and IR850 LED emitter models. The data in the charts that is labeled for the Long Range application apply to both the 1000 µs and 2000 µs response speeds. Table 6: 0.25 mm (0.01 in) Diameter Fibers Opposed Mode Diffuse Mode 4 60 BEAM WIDTH (mm) 40 20 0 -20 Long Medium Standard Fast 3 BEAM WIDTH (mm) Long Medium Standard Fast 2 1 0 -1 -2 -40 -3 -60 0 20 40 60 80 100 -4 0 5 Figure 25. PIT16U 28 10 15 20 DISTANCE (mm) DISTANCE (mm) Figure 26. PBT16U www.bannerengineering.com - Tel: + 1 888 373 6767 25 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Table 7: 0.51 mm (0.02 in) Diameter Fibers Opposed Mode Diffuse Mode 30 400 Long Medium Standard Fast 300 100 0 -100 Long Medium Standard Fast 20 BEAM WIDTH (mm) BEAM WIDTH (mm) 200 -200 10 0 -10 -20 -300 -30 -400 0 50 100 150 200 250 300 0 350 20 40 60 80 100 DISTANCE (mm) DISTANCE (mm) Figure 28. PBT26U Figure 27. PIT26U Table 8: 1.02 mm (0.04 in) Diameter Fibers Opposed Mode Diffuse Mode 100 1200 80 Long Medium Standard Fast 600 300 0 -300 Long Medium Standard Fast 60 BEAM WIDTH (mm) BEAM WIDTH (mm) 900 40 20 0 -20 -600 -40 -900 -60 -80 -1200 0 200 400 600 800 1000 1200 -100 DISTANCE (mm) 0 100 Figure 29. PIT46U 200 300 400 500 DISTANCE (mm) Figure 30. PBT46U Table 9: 1.52 mm (0.06 in) Diameter Fibers Opposed Mode Diffuse Mode 2000 200 1600 BEAM WIDTH (mm) 800 400 0 -400 150 BEAM WIDTH (mm) Long Medium Standard Fast 1200 Long Medium Standard Fast 100 50 0 -50 -800 -100 -1200 -150 -1600 -200 0 -2000 0 500 1000 1500 100 2000 DISTANCE (mm) 200 300 400 500 600 DISTANCE (mm) Figure 32. PBT66U Figure 31. PIT66U www.bannerengineering.com - Tel: + 1 888 373 6767 29 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link Table 10: IT.83.3ST5M6 glass fiber used for opposed mode; BTC1.13.4.T5M6 glass fiber used for diffuse mode Opposed Mode Diffuse Mode 1000 150 Long Medium Standard Fast 800 400 200 0 -200 -400 Long Medium Standard Fast 100 BEAM WIDTH (mm) BEAM WIDTH (mm) 600 50 0 -50 -600 -100 -800 -1000 0 500 1000 1500 DISTANCE (mm) 2000 2500 -150 0 100 300 400 500 DISTANCE (mm) Figure 33. IR850 Figure 34. IR850 5.3 Dimensions 30 200 www.bannerengineering.com - Tel: + 1 888 373 6767 600 700 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 6 Accessories DIN-35-.. 35 mm DIN Rail Model Length DIN-35-70 70 DIN-35-105 105 DIN-35-140 140 L 35 SA-DIN-CLAMP • Pair of metal DIN rail end stops; slide onto DIN rail at either side of the sensor stack • Combination (#2 Phillips, #8 standard slotted) set screw L = 70, 105 or 140 mm Hole center spacing: 35.1 9.1 mm (0.63") Hole size: 25.4 x 5.3 9.1 mm (0.36") 45.0 mm (1.77") SA-DIN-BRACKET • Plastic bracket with mounting screws 10 SA-DIN-BRACKET-10 • Package of 10 plastic brackets with mounting screws 35 10 35 Hole center spacing: A = 16, B = 25.4, C = 15.2 Hole center spacing: A = 16, B = 25.4, C = 15.2 Hole size: A = ø 3.2, B = ø 3.3, C = ø 4.4 Hole size: A = ø 3.2, B = ø 3.3, C = ø 4.4 6.1 Quick-Disconnect Cordsets All measurements are listed in millimeters, unless noted otherwise. 4-Pin Threaded M12/Euro-Style Cordsets—Single Ended Model Length MQDC-406 1.83 m (6 ft) MQDC-415 4.57 m (15 ft) MQDC-430 9.14 m (30 ft) MQDC-450 15.2 m (50 ft) MQDC-406RA 1.83 m (6 ft) MQDC-415RA 4.57 m (15 ft) MQDC-430RA 9.14 m (30 ft) MQDC-450RA 15.2 m (50 ft) Style Dimensions Pinout (Female) 44 Typ. Straight M12 x 1 ø 14.5 1 4 2 3 32 Typ. [1.26"] 30 Typ. [1.18"] Right-Angle M12 x 1 ø 14.5 [0.57"] www.bannerengineering.com - Tel: + 1 888 373 6767 1 = Brown 2 = White 3 = Blue 4 = Black 31 DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 4-Pin Threaded M8/Pico-Style Cordsets—Single Ended Model Length PKG4M-2 2 m (6.56 ft) PKG4M-5 5 m (16.4 ft) Style Dimensions 35 Typ. Straight PKG4M-9 9 m (29.5 ft) PKW4M-2 2 m (6.56 ft) PKW4M-5 ø 9.5 M8 x 1 4 2 1 3 28 Typ. 5 m (16.4 ft) 9 m (29.5 ft) 1 = Brown 2 = White 3 = Blue 4 = Black 20 Typ. Right Angle PKW4M-9 Pinout (Female) M8 x 1 ø 9.5 4-Pin Snap-on M8/Pico-Style Cordsets—Single Ended Model Length PKG4-2 2 m (6.6 ft) PKG4-5 5 m (16.4 ft) Style Dimensions Pinout (Female) 32 Typ. Straight PKG4-10 10 m (32.8 ft) PKW4Z-2 2 m (6.6 ft) PKW4Z-5 5 m (16.4 ft) ø 9.0 15 Typ. ø 10.9 32 www.bannerengineering.com - Tel: + 1 888 373 6767 2 1 3 29 Typ. Right-Angle 4 1 = Brown 2 = White 3 = Blue 4 = Black DF-G2 High Speed Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link 7 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. www.bannerengineering.com - Tel: + 1 888 373 6767 33
DF-G2-KD-Q5 价格&库存

很抱歉,暂时无法提供与“DF-G2-KD-Q5”相匹配的价格&库存,您可以联系我们找货

免费人工找货