0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DF-G1-NR-Q5

DF-G1-NR-Q5

  • 厂商:

    BANNER

  • 封装:

    -

  • 描述:

    DF-G1 DUAL DISPLAY FIBER AMPLIFI

  • 数据手册
  • 价格&库存
DF-G1-NR-Q5 数据手册
DF-G1 Expert™ Dual Display Fiber Optic Light Receiver Instruction Manual Original Instructions 176768 Rev. D 9 September 2015 176768 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver Contents 1 Product Description ........................................................................................................ 3 1.1 Models ....................................................................................................................................3 1.2 Overview ................................................................................................................................ 3 1.3 Top Panel Interface .................................................................................................................. 4 2 External Light Detection Considerations ........................................................................ 5 3 Installation Instructions ................................................................................................ 7 3.1 Mounting Instructions ............................................................................................................... 7 3.2 Installing the Fibers ..................................................................................................................7 3.3 Wiring Diagrams ...................................................................................................................... 8 4 Operating Instructions .................................................................................................. 9 4.1 Run Mode ............................................................................................................................... 9 4.2 Program Mode ......................................................................................................................... 9 4.2.1 TEACH Selection ........................................................................................................... 10 4.2.2 Response Speed ........................................................................................................... 11 4.2.3 Offset Percent .............................................................................................................. 11 4.2.4 Delays/Timers .............................................................................................................. 11 4.2.5 Display Readout ........................................................................................................... 12 4.2.6 Gain Selection .............................................................................................................. 12 4.2.7 Factory Defaults ........................................................................................................... 12 4.3 Remote Input ......................................................................................................................... 12 4.4 Adjust Mode .......................................................................................................................... 13 4.4.1 Two-Point TEACH ...........................................................................................................13 4.4.2 Dynamic TEACH ............................................................................................................ 15 4.4.3 Window SET ..................................................................................................................17 4.4.4 Light SET ......................................................................................................................19 4.4.5 Dark SET ..................................................................................................................... 21 4.4.6 Calibration SET ..............................................................................................................23 4.4.7 Troubleshooting ............................................................................................................24 5 Specifications 5.1 Dimensions 6 Accessories .............................................................................................................. 25 ............................................................................................................................ 26 .................................................................................................................. 27 6.1 Quick-Disconnect Cordsets ...................................................................................................... 27 7 Banner Engineering Corp Limited Warranty ................................................................. 29 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver 1 Product Description Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies • • • • • • • • • • • A full feature DIN rail mounted fiber optic light receiver for external light detection Capable of detecting light level changes over all visible light colors plus infrared and near ultraviolet Easy to apply in many LED and lamp inspection stations Easy to read dual digital displays show both signal level and threshold simultaneously Lever action fiber clamp provides stable, reliable, and trouble-free fiber clamping Simple user interface ensures easy sensor set-up and programming via displays and switches/buttons or remote input teach wire TEACH and SET methods ensure optimal gain and threshold settings Operates over a wide range of light levels User has full control over all operating parameters: threshold, Light Operate or Dark Operate, output timing functions, gain level, and response speed Response speeds of 50 ms and 150 ms Sleek 10 mm wide housing mounts to 35 mm DIN rail WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. 1.1 Models Model Outputs DF-G1-NR-2M Single NPN DF-G1-PR-2M Single PNP DF-G1-NR-Q5 Single NPN DF-G1-PR-Q5 Single PNP DF-G1-NR-Q7 Single NPN DF-G1-PR-Q7 Single PNP Connector1 2 m (6.5 ft) cable, 4-wire 150 mm (6 in) PVC pigtail, M12 Euro QD connector, 4-pin Integral M8 Pico QD connector, 4-pin 1.2 Overview The DF-G1 is an easy-to-use, DIN-rail-mountable fiber optic light receiver. It provides high-performance sensing for external light applications. The sensor’s compact housing has dual digital displays (Red/Green) and a bright output LED for easy programming and status monitoring during operation. The sensor features a single discrete output, either NPN or PNP, by model. An accessory clamp is available to secure a bank of connected sensors together on a DIN rail (see Accessories on page 27). 1 Connector options: • • • A model with a QD connector requires a mating cordset (see Quick-Disconnect Cordsets on page 27). For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G1-NR-9M). For 150 mm (6 in) PVC pigtail, M8 Pico QD connector, 4-pin change the suffix 2M to Q3 in the 2 m model number (example, DF-G1-NR-Q3). www.bannerengineering.com - Tel: 763.544.3164 3 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver 1 Output LED 2 LO/DO Switch 3 RUN/PRG/ADJ Mode Switch 4 Lever Action Fiber Clamp 5 Red Signal Level 6 Green Threshold 7 +/SET/- Rocker Button Figure 1. DF-G1 Model Features 1.3 Top Panel Interface Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ mode switch, LO/DO switch, +/SET/- rocker button, dual red/green digital displays, and output LED. RUN/PRG/ADJ Mode Switch The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode. RUN mode allows the sensor to operate normally and prevents unintentional programming changes via the +/SET/- rocker button. PRG mode allows the sensor to be programmed through the display-driven programming menu (see Program Mode on page 9 ). ADJ mode allows the user to perform Expert TEACH/SET methods and Manual Adjust (see Adjust Mode on page 13 ). LO/DO Switch The LO/DO switch selects Light Operate or Dark Operate mode. In Light Operate mode, the output is ON when the sensing condition is above the threshold. (For Window SET, the output is ON when the sensing condition is inside the window.) In Dark Operate mode, the output is ON when the sensing condition is below the threshold. (For Window SET, the output is ON when the sensing condition is outside the window.) +/SET/- Rocker Button The +/SET/- rocker button is a 3-way button. The +/- positions are engaged by rocking the button left/ right. The SET position is engaged by clicking down the button while the rocker is in the middle position. All three button positions are used during PRG mode to navigate the display-driven programming menu. During ADJ mode, SET is used to perform TEACH/SET methods and +/- are used to manually adjust the threshold(s). The rocker button is disabled during RUN mode, except when using Window SET, see Window SET on page 17. Red/Green Digital Displays During RUN and ADJ modes, the Red display shows the signal level, and the Green display shows the threshold. During PRG mode, both displays are used to navigate the display-driven programming menu. Output LED The output LED provides a visible indication when the output is activated. 4 www.bannerengineering.com - Tel: 763.544.3164 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver 2 External Light Detection Considerations External lighting variations must be carefully considered when applying this sensor because the amount of background light can measurably affect detection reliability. The DF-G1 Fiber Optic Light Receiver detects both the light of interest and ambient light. Figure 2 on page 5 shows simulated light levels for both the dark state and the light state. The dark state is the amount of light detected when the external light of interest is not present. Conversely, the light state is the amount of light detected when both the ambient and external light of interest are present. In the dark state, the graph shows that light detected can change with time. Changes in the dark state light levels are caused by variations in the ambient light levels (perhaps sunlight or factory light variations). Typical variations in the detected light level when the external light of interest is present (light state) are also shown in the figure. Note again that the light level can vary with changes in the ambient light level. Contrast = DL BD Detected Light Darkest Light Level Brightest Dark Level Dark State Light State DL BD Dark State Time Figure 2. Light Levels A successful sensing application is obtained when the sensor can detect between the light and dark conditions. Two important points shown in Figure 2 on page 5 are the brightest dark level (BD) and the darkest light level (DL). These values represent the key values for determining if the application will be successfully detected. The application goal is to maximize the light level detected in the darkest light state. Using this concept of contrast, calculate the contrast available to ensure a good sensing application. The contrast should be greater than 2 for robust sensing applications. Contrast = DL/BD The DF-G1 Fiber Optic Light Receiver detects light over a wide range of the light spectrum and over a wide range of light intensity. Table 1 on page 5 and Table 2 on page 5 depict the typical minium light intensity as well as the maximum light intensity values that can be detected. Use the tables as a guide for comparing detectable light levels for various light sources. In Table 1 on page 5, values for the light intensity are in Lux and in Table 2 on page 5 values for light intensity are in µW/cm². Table 1: Typical Light Detection Capabilities in Lux PIT26U Light Source PIT66U Glass Fiber IMT.756.6S-HT Minimum Maximum Minimum Maximum Minimum Maximum Green (535 nm) 3.0 50,000 0.9 15,000 0.9 15,000 Red (626 nm) 1.0 16,000 0.3 4,800 0.3 4,800 Blue (485 nm) 0.7 11,000 0.4 3,300 0.4 3,300 White (cool) 3.0 50,000 0.9 15,000 0.9 15,000 Table 2: Typical Light Detection Capabilities in µW/cm² PIT26U Light Source PIT66U Glass Fiber IMT.756.6S-HT Minimum Maximum Minimum Maximum Minimum Maximum Green (535 nm) 0.5 7,500 0.2 2,250 0.2 2,250 Red (626 nm) 0.5 7,500 0.2 2,250 0.2 2,250 Blue (485 nm) 0.6 9,000 0.3 2,700 0.3 2,700 White (cool) 0.5 7,500 0.2 2,250 0.2 2,250 Infrared (850 nm) 2.0 30,000 0.6 9,000 0.1 1,500 www.bannerengineering.com - Tel: 763.544.3164 5 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver The two tables above are a guide for detecting external lights. The sensor does not measure absolute light levels. It detects the presence of an external light source based on the received light intensity relative to a user-set threshold. These tables demonstrate that the sensor will detect light sources typical in many industrial applications and highlights that the selection of the fiber optic cable diameter affects the limits of light detection. 6 www.bannerengineering.com - Tel: 763.544.3164 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver 3 Installation Instructions 3.1 Mounting Instructions Mount on a DIN Rail 1. Hook the DIN rail clip on the bottom of the DF-G1 over the edge of the DIN rail (1). 2. Push the DF-G1 up on the DIN rail (1). 3. Pivot the DF-G1 onto the DIN rail, pressing until it snaps into place (2). Mount to the Accessory Bracket 1. Position the DF-G1 in the SA-DIN-BRACKET. 2. Insert the supplied M3 screws. 3. Tighten the screws. Remove from a DIN rail 1. Push the DF-G1 up on the DIN rail (1). 2. Pivot the DF-G1 away from the DIN rail and remove it (2). 3.2 Installing the Fibers Follow these steps to install glass or plastic fibers. 1. Open the dust cover. 2. Move the fiber clamp forward to unlock it. 3. Insert the fiber(s) into the fiber port(s) until they stop. 4. Move the fiber clamp backward to lock the fiber(s). 5. Close the dust cover. www.bannerengineering.com - Tel: 763.544.3164 Slide forward to release fiber Fiber Port 7 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver 3.3 Wiring Diagrams NPN Models PNP Models Key 10-30V dc 10-30V dc Load Load Remote Programming (N.O.) Remote Programming (N.O.) NOTE: Open lead wires must be connected to a terminal block. 8 www.bannerengineering.com - Tel: 763.544.3164 1 2 3 4 = = = = Brown White Blue Black DF-G1 Expert™ Dual Display Fiber Optic Light Receiver 4 Operating Instructions 4.1 Run Mode Run mode allows the sensor to operate normally and prevents unintentional programming changes. The +/SET/- rocker button is disabled during RUN mode, except when using Window SET, see Window SET on page 17. 4.2 Program Mode Program (PRG) mode allows the following settings to be programmed in the DF-G1 (refer to Figure 3 on page 10 and Figure 5 on page 13 for programming). www.bannerengineering.com - Tel: 763.544.3164 9 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver Figure 3. 4.2.1 TEACH Selection The DF-G1 can be programmed for one of the following TEACH/SET methods: • Two-Point TEACH • Dynamic TEACH • Window SET • Light SET • Dark SET 10 www.bannerengineering.com - Tel: 763.544.3164 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver • Calibration SET NOTE: A TEACH Selection must be selected by programming before TEACH/SET methods can be used. 4.2.2 Response Speed The DF-G1 can be programmed for one of the following Response Speeds: Response Speed Display Range Crosstalk Avoidance Algorithm 50 ms 0 – 9999 Disabled 150 ms 0 – 9999 Enabled 4.2.3 Offset Percent The Offset Percent is used during the Window, Light, or Dark SET methods. The threshold(s) are positioned a programmable % offset from the taught condition. The allowable range depends upon the Response Speed Mode, as shown below: Response Speed MIN % MAX % 50 ms 10 999 150 ms 10 999 The offset percent can also be programmed to Minimum Offset. This allows the DF-G1 to set the threshold(s) as close as possible to the presented condition, but still provide for reliable sensing. NOTE: Offset Percent MUST be programmed to Minimum Offset for Dark SET to accept conditions of no signal (0 counts). 4.2.4 Delays/Timers ON/OFF Delays and ON/OFF One-Shot timers can be programmed between 1 9999 ms (a value of 0 disables the delay/ timer). Figure 4 on page 11 defines how the delays/timers affect the output behavior. ON Output OFF OFF Delay Some combinations of delays/timers are not allowed. The DF-G1 programming menu automatically disables invalid combinations of delays/timers. When invalid timing functions are attempted, only the last timing function will be implemented. For example, if an Off Delay is selected and then an On One-Shot Timer is added, this invalid combination will force the sensor to have the On One-Shot Timer function and not have the Off Delay.The following table shows the allowable combinations of delays/timers: OFF Delay OFF One-Shot Timer OFF 1-Shot D D D D ON Delay D D ON 1-Shot D D (D = 1 - 9999 ms) Time Figure 4. DF-G1 Delays/Timers OFF Delay OFF One-Shot Timer ON Delay ON One-Shot Timer - OK OK N/A OK - N/A N/A www.bannerengineering.com - Tel: 763.544.3164 11 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver OFF Delay OFF One-Shot Timer ON Delay ON One-Shot Timer ON Delay OK N/A - OK ON One-Shot Timer N/A N/A OK - 4.2.5 Display Readout The readout of the digital displays can be programmed for the following options: • Signal/Threshold readout - Numeric (1234) or % (123P) • ECO mode - Enabled or Disabled (ECO mode dims the displays to reduce current consumption) • Display Orientation - Normal ( ) or Flipped ( ) 4.2.6 Gain Selection The DF-G1 can operate in Auto Gain mode or the Gain can be fixed to be in Gain 1…8. In Auto Gain, the DF-G1 optimizes the gain during a TEACH/SET method for the presented condition(s). While viewing the fixed gains in the Gain Selection choice list, the DF-G1 will automatically switch to the selected gain and display the measured signal on the Red display. This allows for easy and quick evaluation of the fixed gain mode. 4.2.7 Factory Defaults The Factory Defaults menu allows the DF-G1 to be easily restored back to original factory default settings (see Factory Default Settings in Specifications on page 25). 4.3 Remote Input The remote input may be used to perform TEACH/SET methods and to program the sensor remotely. Connect the white input wire of the sensor to ground (0 V dc), with a remote switch connected between them. Pulse the remote input according to the diagram shown in Figure 5 on page 13. Follow the instructions in the TEACH/SET sections in Adjust Mode on page 13 to perform a TEACH/SET method. The sensor exits TEACH and remote programming modes after a 60 second timeout. Users may exit TEACH and remote programming modes by setting the remote input low for more than 2 seconds. In either case, the sensor returns to Run mode without saving any new settings. 12 www.bannerengineering.com - Tel: 763.544.3164 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver Remote Input NOTE: Follow procedure for the selected TEACH/SET method (highlighted in black box) chosen in the TEACH Selection menu Two Point TEACH 2Pt tch, then 1234 2nd PASS or FAIL (with % Minimum Diff.) TEACH METHODS 1x Pulse Timing (T) 0.04 seconds < T < 0.8 seconds Timing between Pulse groups > 1 second 1x Dynamic TEACH dYn tch, then 1234 dYn PASS or FAIL (with % Minimum Diff.) 1x or 1x Light SET Lt SEt then PASS or FAIL* Dark SET dr SEt then PASS or FAIL* Window SET wind SEt then PASS or FAIL* Calibration SET CAL SET then PASS or FAIL 1x 1x 1x 1x (continued from below) PRO Advanced 3x * with % offset if not hard fail 2x PRO Basic 1x 1x 0 ms 2 Pt. TEACH 2x 100 ms 2x Dynamic TEACH 3x 200 ms 3x Window SET Light SET 4x 500 ms 5x 1000 ms 6x 2000 ms 4x Dark SET CAL SET 5x 6x 2x 50 ms 150 ms PROGRAM (Basic) 2x Offset Percent 1x Min. Offset 2x 25% 50% 75% 100% 200% 3x 4x 5x 6x 4x 5x 4x Button Lock 1x Button Unlock (uloc) 2x Button Lock (loc) 5x Display Readout 1x Numeric 2x Percent 3x 4x ECO Numeric ECO Percent 5x Numeric Flipped 6x Percent Flipped ECO Numeric Flipped ECO Percent Flipped 7x 8x 3x 3x Response Speed 1x 3x Off Delay 1x TEACH Selection PROGRAM (Advanced) 2x PRO Advanced (continued at top) 6x Off One-Shot 1x 0 ms 2x 100 ms 3x 200 ms 4x 500 ms 5x 1000 ms 6x 2000 ms On Delay 1x 0 ms 2x 100 ms 3x 200 ms 4x 500 ms 5x 1000 ms 6x 2000 ms On One-Shot 1x 0 ms 2x 100 ms 3x 200 ms 4x 500 ms 5x 1000 ms 6x 2000 ms Gain Select 1x Auto Gain 2x Gain 1 3x Gain 2 Gain 3 4x 5x 4x Button Lock (loc) or Unlock (uloc) 6x 8x Factory Default Settings 8x 7x 9x Gain 4 Gain 5 Gain 6 Gain 7 Gain 8 Figure 5. Remote Input Flowchart 4.4 Adjust Mode Sliding the RUN/PRG/ADJ mode switch to the ADJ position allows the user to perform Expert TEACH/SET methods and Manual Adjustment of the threshold(s). 4.4.1 Two-Point TEACH • • Establishes a single switching threshold Threshold can be adjusted by using the "+" and "-" rocker button (Manual Adjust) www.bannerengineering.com - Tel: 763.544.3164 13 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver Two-Point TEACH is used when two conditions can be presented statically to the sensor. The sensor locates a single sensing threshold (the switch point) midway between the two taught conditions, with the Output ON condition on one side, and the Output OFF condition on the other. Darkest Taught Condition Lightest Taught Condition Sensor positions threshold midway between taught conditions Output OFF Darkest (no signal) Output ON Position adjusted by Manual Adjust Most Light (saturated signal) Figure 6. Two-Point TEACH (Light Operate shown) The Output ON and OFF conditions can be reversed by using the LO/DO (Light Operate/ Dark Operate) switch. Two-Point TEACH and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Follow these steps to perform a Two-Point TEACH: Note: TEACH Selection must be programmed to 2Pt tcH. 1. Enter Adjust mode. Method Action Result SET Button 2 Set the Mode switch to ADJ. Display: Red - Signal Level; Green Threshold Remote Input 3 No action is required; sensor is ready for the Two-Point TEACH method 2. Teach the first condition. Method SET Button Action Result a. Present the first condition. Display: Flashes "2Pt tch" then holds on "1234 2nd" b. Click the SET rocker button. Remote Input a. Present the first condition. T b. Single-pulse the remote input. 3. Teach the second condition. 2 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 3 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds 14 www.bannerengineering.com - Tel: 763.544.3164 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver Method SET Button Action Result TEACH Accepted a. Present the second condition. Displays alternate "PASS" and % Minimum Difference4; Sensor returns to Adjust mode b. Click the SET rocker button. Remote Input a. Present the second condition. T b. Single-pulse the remote input. TEACH Not Accepted Displays alternate "FAIL" and % Minimum Difference4; Sensor returns to Adjust mode 4. Return to Run mode. Method Action Result SET Button Move the Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action is required; sensor returns to RUN mode automatically 4.4.2 Dynamic TEACH • • • Teaches on-the-fly Establishes a single switching threshold Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust) Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actual sensing conditions, taking multiple samples of the light and dark conditions and automatically setting the threshold at the optimum level. Darkest Taught Condition Lightest Taught Condition Sensor positions threshold midway between taught conditions Output OFF Darkest (no signal) Output ON Position adjusted by Manual Adjust Most Light (saturated signal) Figure 7. Dynamic TEACH (Light Operate shown) The output ON and OFF conditions can be reversed using the LO/DO switch. Dynamic TEACH and Manual Adjust Moves switching threshold value up or down to make adjustments • Slide Mode switch to ADJ to enter Adjust mode 4 See Troubleshooting on page 24 for more explanation of the % Minimum Difference displayed after the Two-Point TEACH method. www.bannerengineering.com - Tel: 763.544.3164 15 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver • • Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Follow these steps to perform Dynamic TEACH: NOTE: TEACH Selection must be programmed to dYn tcH. 1. Enter Adjust Mode. Method Action Result SET Button 5 Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold Remote Input 6 No action required; sensor is ready for Dynamic TEACH method 2. Enter Dynamic TEACH. Method Action Result SET Button Click the SET rocker button Display: Flashes "dYn tch" then holds on "1234 dYn" Remote Input Single-pulse remote input T 3. Present ON and OFF Conditions. Method Action Result SET Button Present ON and OFF conditions Display: Red - Signal Level; Green Threshold Remote Input Present ON and OFF conditions 4. Exit Dynamic TEACH. 5 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 6 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds 16 www.bannerengineering.com - Tel: 763.544.3164 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver Method Action Result SET Button Click the SET rocker button TEACH Accepted Remote Input Single-pulse remote input T Displays alternate "PASS" with % Minimum Difference7, Sensor returns to Adjust mode TEACH Not Accepted Displays alternate "FAIL" with % Minimum Difference7, Sensor returns to Adjust mode 5. Return to RUN Mode. Method Action Result SET Button Move Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action required; sensor returns to RUN mode automatically 4.4.3 Window SET • • • • • Sets window thresholds that extend a programmable % offset above and below the presented condition All other conditions (lighter or darker) cause the output to change state Sensing window center can be adjusted using "+" and "-" rocker button (Manual Adjust) Recommended for applications where a product may not always appear in the same place, or when other signals may appear See Program Mode on page 9 for programming the Offset Percent setting (to increase/decrease the window size) A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and below the presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside the window, and the Output OFF conditions outside the window. NOTE: For Window SET and Light SET, the maximum offset threshold percent is 90%. 7 See Troubleshooting on page 24 for more explanation of the % Minimum Difference displayed after the Dynamic TEACH method. www.bannerengineering.com - Tel: 763.544.3164 17 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver Sensing window center adjusted by Manual Adjust Output OFF Darkest (no signal) Output ON Sensor positions window thresholds a programmable % offset from the presented condition Output OFF Condition Presented Most Light (saturated signal) Figure 8. Window SET (Light Operate shown) Output ON and OFF conditions can be reversed using the LO/DO switch. Window SET and Manual Adjust Moves sensing window center value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the sensing window center value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Follow these steps to perform a Window SET: Note: TEACH Selection must be programmed to wind SEt. 1. Enter Adjust Mode Method Action Result SET Button 8 Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold Remote Input 9 No action required; sensor is ready for Window SET method 2. SET Sensing Condition 8 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 9 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds 18 www.bannerengineering.com - Tel: 763.544.3164 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver Method SET Button Remote Input Action Result • Present sensing condition • Click the SET rocker button • Present sensing condition • Single-pulse the remote input Threshold Condition Accepted Displays read "wInd SEt" then alternate "PASS" with % Offset10; Sensor returns to Adjust mode T Threshold Condition Not Accepted Displays read "wInd SEt" then alternate "FAIL" with minimum % Offset10 for sensing condition; Sensor returns to Adjust mode 3. Return to RUN Mode Method Action Result SET Button Move Mode switch to Run Remote Input No action required; sensor returns to Run mode automatically Display: Red - Signal Level; Green Window Center (see Figure 9 on page 19 for instructions on how to display upper and lower thresholds) Window SET (during RUN mode) Upon sensor power-up, Window Center is displayed Upper Threshold Displayed Window Center Displayed Lower Threshold Displayed Figure 9. Upper and Lower Thresholds 4.4.4 Light SET • • • • • Sets a threshold a programmable % offset below the presented condition Changes output state on any condition darker than the threshold condition Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust) Recommended for applications where only one condition is known, for example a stable light background with varying darker targets See Program Mode on page 9 for programming the Offset Percent setting A single sensing condition is presented, and the sensor positions a threshold a programmable % offset below the presented condition. When a condition darker than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting. 10 See Troubleshooting on page 24 for more explanation of the % Offset displayed after the Window SET method www.bannerengineering.com - Tel: 763.544.3164 19 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver NOTE: For Window SET and Light SET, the maximum offset threshold percent is 90%. Threshold position adjusted by Manual Adjust Sensor positions threshold a programmable % offset below the presented condition Output OFF Darkest (no signal) Output ON Condition Presented Most Light (saturated signal) Figure 10. Light SET (Light Operate shown) Light SET and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Follow these steps to perform a Light SET: Note: TEACH Selection must be programmed to Lt SEt. 1. Enter Adjust Mode Method Action Result SET Button 11 Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold Remote Input 12 No action is required; sensor is ready for Light SET method 2. SET Sensing Condition 11 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 12 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds 20 www.bannerengineering.com - Tel: 763.544.3164 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver Method SET Button Remote Input Action Result • Present sensing condition • Click the SET rocker button • Present sensing condition • Single-pulse the remote input Threshold Condition Accepted Displays read "Lt SEt" then alternate "PASS" with % Offset13; Sensor returns to Adjust mode T Threshold Condition Not Accepted Displays read "Lt SEt" then alternate "FAIL" with minimum % Offset13 for sensing condition; Sensor returns to Adjust mode 3. Return to RUN Mode Method Action Result SET Button Move Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action required; sensor returns to RUN mode automatically 4.4.5 Dark SET • • • • • Sets a threshold a programmable % offset above the presented condition Any condition lighter than the threshold condition causes the output to change state Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust) Recommended for applications where only one condition is known, for example a stable dark background with varying lighter targets See Program Mode on page 9 for programming the Offset Percent setting NOTE: Offset Percent MUST be programmed to Minimum Offset to accept conditions of no signal (0 counts). A single sensing condition is presented, and the sensor positions a threshold a programmable % offset above the presented condition. When a condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting. 13 See Troubleshooting on page 24 for more explanation of the % Offset displayed after the Light SET method www.bannerengineering.com - Tel: 763.544.3164 21 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver Threshold position adjusted by Manual Adjust Sensor positions threshold a programmable % offset above the presented condition Output OFF Darkest (no signal) Output ON Condition Presented Most Light (saturated signal) Figure 11. Dark SET (Light Operate shown) Dark SET and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Follow these steps to perform a Dark SET: Note: TEACH Selection must be programmed to dr SEt. 1. Enter Adjust Mode. Method Action Result SET Button 14 Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold Remote Input 15 No action required; sensor is ready for Dark SET method 2. SET Sensing Condition. Method Action SET Button Remote Input Result • Present sensing condition • Click the SET rocker button • Present sensing condition • Single-pulse the remote input Threshold Condition Accepted Displays read "dr SEt" then alternate "PASS" with % Offset16; Sensor returns to Adjust mode T Threshold Condition Not Accepted Displays read "dr SEt" then alternate "FAIL" with minimum % Offset16 for sensing condition; Sensor returns to Adjust mode 3. Return to RUN Mode. 14 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 15 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds 16 See Troubleshooting on page 24 for more explanation of the % Offset displayed after the Dark SET method 22 www.bannerengineering.com - Tel: 763.544.3164 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver Method Action Result SET Button Move Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action required; sensor returns to RUN mode automatically 4.4.6 Calibration SET • • Sets a threshold exactly at the presented condition Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust) A single sensing condition is presented, and the sensor positions a threshold exactly at the presented condition. When a condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting. Threshold position adjusted by Manual Adjust Sensor positions threshold exactly at the presented condition Output OFF Darkest (no signal) Output ON Condition Presented Most Light (saturated signal) Figure 12. Calibration SET (Light Operate shown) Calibration SET and Manual Adjust Moves switching threshold value up or down to make adjustments • • • Slide Mode switch to ADJ to enter Adjust mode Press "+" to increase; press "-" to decrease ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Follow these steps to perform a Calibration SET: Note: TEACH Selection must be programmed to CAL SEt. 1. Enter Adjust Mode Method Action SET Button 17 Remote Input 18 • Result Set Mode switch to ADJ Display: Red - Signal Level; Green Threshold No action required; sensor is ready for Calibration SET method 2. SET Sensing Condition 17 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds 18 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds www.bannerengineering.com - Tel: 763.544.3164 23 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver Method Action SET Button Remote Input Result • Present sensing condition • Click the SET rocker button • Present sensing condition • Single-pulse the remote input Threshold Condition Accepted Displays read "cAL SEt" then flashes "PASS"; Sensor returns to Adjust mode T Threshold Condition Unacceptable Displays read "cAL SEt" then flashes "FAIL"; Sensor returns to Adjust mode 3. Return to RUN Mode Method Action Result SET Button Move Mode switch to RUN Display: Red - Signal Level; Green Threshold Remote Input No action required; sensor returns to RUN mode automatically 4.4.7 Troubleshooting Percent Minimum Difference after TEACH The Two-Point and Dynamic TEACH methods will flash a % minimum difference on the displays after a PASS or FAIL. Value PASS/FAIL Description 0 to 99% FAIL The difference of the taught conditions does not meet the required minimum 100 to 300% PASS The difference of the taught conditions just meets/exceeds the required minimum, minor sensing variables may affect sensing reliability 300 to 600% PASS The difference of the taught conditions sufficiently exceeds the required minimum, minor sensing variables will not affect sensing reliability 600% + PASS The difference of the taught conditions greatly exceeds the required minimum, very stable operation Percent Offset after SET The Window, Dark, and Light SET methods will flash a % offset on the displays after a PASS or FAIL. SET Result % Offset Meaning PASS (with % Offset) Displays the % offset used for the SET method FAIL (with % Offset) Displays the minimum required % offset necessary to PASS the SET method FAIL (without % Offset) Presented condition cannot be used for the SET method NOTE: For Window SET and Light SET, the maximum offset threshold percent is 90%. 24 www.bannerengineering.com - Tel: 763.544.3164 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver 5 Specifications Adjustments 3-way RUN/PRG/ADJ Mode Switch 2-way LO/DO Switch Supply Voltage 3-way +/SET/- Rocker Button 10 to 30 V dc Class 2 (10% maximum ripple) • Expert-style teaching (Two-Point and Dynamic TEACH, Light/ Power and Current Consumption (exclusive of load) Dark/Window/Calibration SET) Standard display mode: 960 mW, Current consumption < 40 mA at • Manually adjust sensitivity (from "+" and "-" rocker button 24 V dc only) ECO display mode: 720 mW, Current consumption < 30 mA at 24 V dc • Response Speed, TEACH Selection, Offset Percent, Delays/ Supply Protection Circuitry Timers, Display Readout, Gain Selection, Factory Defaults Protected against reverse polarity and transient overvoltages (from top panel or remote input) • Top panel interface lockout (from remote input only) Delay at Power-Up 500 milliseconds maximum; outputs do not conduct during this time Factory Default Settings: Light Detection Range 400 to 1100 nm Output Configuration 1 current sinking (NPN) or 1 current sourcing (PNP) output, depending on model Output Rating 100 mA maximum load (derate 1 mA per °C above 30 °C) OFF-state leakage current: < 5 μA at 30 V dc ON-state saturation voltage: NPN: < 1.5 V; PNP < 2 V Output Protection Protected against output short-circuit, continuous overload, transient overvoltages, and false pulse on power-up Output Response Time 50 ms 150 ms Temperature Drift 0.2% per °C Indicators Red 4-digit Display: Signal Level Green 4-digit Display: Threshold (In Program Mode, Red and Green displays are used for programming menus) Yellow LED: Output conducting Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to http:// www.bannerengineering.com. Supply Wiring Required Overcurrent Protection 20 5.0 Amps 22 3.0 Amps 24 2.0 Amps 26 1.0 Amps 28 0.8 Amps 30 0.5 Amps Setting Factory Default Threshold 5000 TEACH Selection Two-Point TEACH Response Speed 50 ms Offset Percent 50% OFF Delay 0 (Disabled) OFF One-Shot 0 (Disabled) ON Delay 0 (Disabled) ON One-Shot 0 (Disabled) Display Readout Numeric, ECO disabled, Normal Orientation Gain Selection Auto Gain Connections PVC-jacketed 2 m or 9 m (6.5 ft. or 30 ft.) 4-wire integral cable; or integral 4-pin M8/Pico-style quick disconnect; or 150 mm (6 in.) cable with a 4-pin M12/Euro-style quick disconnect; or 150 mm (6 in.) cable with a 4-pin M8/Pico-style quick disconnect. Construction Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear polycarbonate cover Environmental Rating IEC IP50, NEMA 1 Operating Conditions Temperature: −10 °C to +55 °C (+14 °F to +131 °F) Storage Temperature: −20 °C to +85 °C (−4 °F to +185 °F) Humidity: 90% at +60 °C maximum relative humidity (noncondensing) Certifications www.bannerengineering.com - Tel: 763.544.3164 Industrial Control Equipment 3TJJ 25 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver 5.1 Dimensions All measurements are listed in millimeters (inches), unless noted otherwise. 26 www.bannerengineering.com - Tel: 763.544.3164 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver 6 Accessories DIN-35-.. 35 mm DIN Rail Model Length DIN-35-70 70 DIN-35-105 105 DIN-35-140 140 L 35 SA-DIN-CLAMP Pair of metal DIN rail end stops; slide onto DIN rail at • either side of the sensor stack • Combination (#2 Phillips, #8 standard slotted) set screw L = 70, 105 or 140 mm 9.1 mm (0.63") Hole center spacing: 35.1 Hole size: 25.4 x 5.3 9.1 mm (0.36") 45.0 mm (1.77") SA-DIN-BRACKET • Plastic bracket with mounting screws 10 SA-DIN-BRACKET-10 Package of 10 plastic • brackets with mounting screws 35 10 35 Hole center spacing: A = 16, B = 25.4, C = 15.2 Hole center spacing: A = 16, B = 25.4, C = 15.2 Hole size: A = ø 3.2, B = ø 3.3, C = ø 4.4 Hole size: A = ø 3.2, B = ø 3.3, C = ø 4.4 6.1 Quick-Disconnect Cordsets All measurements are listed in millimeters, unless noted otherwise. 4-Pin Threaded M12/Euro-Style Cordsets Model Length MQDC-406 1.83 m (6 ft) MQDC-415 4.57 m (15 ft) MQDC-430 9.14 m (30 ft) MQDC-450 15.2 m (50 ft) MQDC-406RA 1.83 m (6 ft) MQDC-415RA 4.57 m (15 ft) MQDC-430RA 9.14 m (30 ft) Style Dimensions 44 Typ. Straight M12 x 1 ø 14.5 15.2 m (50 ft) 2 1 3 4 32 Typ. [1.26"] 30 Typ. [1.18"] Right-Angle MQDC-450RA Pinout (Female) 1 2 3 4 = = = = Brown White Blue Black M12 x 1 ø 14.5 [0.57"] www.bannerengineering.com - Tel: 763.544.3164 27 DF-G1 Expert™ Dual Display Fiber Optic Light Receiver 4-Pin Threaded M8/Pico-Style Cordsets Model Length PKG4M-2 2 m (6.56 ft) PKG4M-5 5 m (16.4 ft) PKG4M-9 9 m (29.5 ft) PKW4M-2 2 m (6.56 ft) PKW4M-5 5 m (16.4 ft) Style Dimensions 35 Typ. Straight ø 9.5 M8 x 1 4 2 1 3 28 Typ. 1 = Brown 2 = White 3 = Blue 4 = Black 20 Typ. Right Angle PKW4M-9 Pinout (Female) 9 m (29.5 ft) M8 x 1 ø 9.5 4-Pin Snap-on M8/Pico-Style Cordsets Model Length PKG4-2 2 m (6.6 ft) PKG4-5 5 m (16.4 ft) Style Dimensions Pinout (Female) 32 Typ. Straight PKG4-10 10 m (32.8 ft) PKW4Z-2 2 m (6.6 ft) PKW4Z-5 5 m (16.4 ft) ø 9.0 4 15 Typ. ø 10.9 28 3 29 Typ. Right-Angle www.bannerengineering.com - Tel: 763.544.3164 2 1 1 = Brown 2 = White 3 = Blue 4 = Black DF-G1 Expert™ Dual Display Fiber Optic Light Receiver 7 Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. www.bannerengineering.com - Tel: 763.544.3164 29
DF-G1-NR-Q5 价格&库存

很抱歉,暂时无法提供与“DF-G1-NR-Q5”相匹配的价格&库存,您可以联系我们找货

免费人工找货