0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2-7980-031

2-7980-031

  • 厂商:

    FREDERICK

  • 封装:

    Module

  • 描述:

    VAC GAUGE CC10 NW25/KF25 SST

  • 数据手册
  • 价格&库存
2-7980-031 数据手册
CC-10 Wide Range Active Vacuum Gauge Part Number: 2-7980-0XX Operating Specifications 1 Operating Range Communications Analog Output Programmable Set Points Supply Voltage Maximum Power Calibration Medium Overpressure Digital Output Resolution Analog Output Resolution Operating Temperature Storage Temperature Bakeout Temperature Response Time Accuracy 10-9 Torr to 10-1 Torr 10-1 Torr to 200 Torr 200 Torr to 1000 Torr Analog Output Display Readable Distance Description 10-9 Torr 1x to 1000 Torr RS-485 0 V to 10 V linear/logarithmic 3 relays +22 V DC to +26 V DC 8W Dry air or nitrogen 150 psi 2 significant digits with exponent 16 bits 0 °C to 50 °C -40 °C to 85 °C 120 °C (electronics removed) ≤ 500 ms The CC-10 Active Gauge utilizes dual sensor technology to replace multiple conventional vacuum gauges, permitting seamless measurement of twelve decades of pressure. It has a variety of features including a wide range of measurement from 1 x 10-9 Torr up to 1000 Torr, RS-485 communications, three programmable set points, and a selectable analog output. The bright LED display makes it easy to read from a distance. Options can be set from either four touch controls located on the front of the unit or through RS-485 communications. The simplicity of use and wide measurement range make this unit an excellent choice for a variety of vacuum applications. ±0.2 of decade ±15% of reading ±5% of reading ±10 mV 4 m (13 ft) Analog Output Behavior Physical Characteristics Enclosure Material Electrical Connections Weight with Sensor Weight without Sensor Dimensions Metallized plastic D-Sub 15-pin male 698 g (1.54 lbs) (NW25 Flange) 355 g (0.78 lbs) 3.7” x 2.75” x 6.3” (NW25 Flange) RS-485 Commands (assume address 0) 2 0R1 0R2 0R5 0W1XXXX 0W2XXXXXXXX 0C1 0S1 0S2 Read units Read SP1L and SP1H Read analog output set parameter Set pressure unit Set SP1L and SP1H Crystal gauge atm adjustment Read pressure data Read error status Benefits Wide measurement range Compact design Easy to read LED display Analog and RS-485 communications standard Excellent resolution and repeatability Superior unit to unit performance Excellent customer support • • • • • • • Ratings and Compliance • • • See the Televac website at www.televac.com for a list of definitions for terms used in the operating specifications. All test data was acquired at 23 °C. 1 email: sales@frederickscompany.com tel: +1 215 947 2500 CE certified to EN 61010-1, EN 61236-1 RoHS compliant IP40 2 See the CC-10 Instruction Manual for all RS-485 command descriptions and setup instructions. web: frederickscompany.com form: cc10_ds rev D page: 1/2 CC-10 Wide Range Active Vacuum Gauge Part Number: 2-7980-0XX Electrical Connections Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Dimensional Drawings Description Analog Out (Ground) RS-485 A (-) SP3 Out SP2 Out SP1 Out Zero adjust input (signal in) EXT Vcc (signal in) Supply voltage (+) Analog Out (0 to 10) V RS-485 B (+) SP2, SP3 COM SP1 COM HV inhibit signal (signal in) Atm adjust input (signal in) Supply Voltage (-) Materials Exposed to Vacuum Molybdenum Glass Copper Stainless Steel Gold Chromium Solder Fluorocarbon Elastomer Quartz Ordering Information Set Points The CC-10 has three set points. All three are optically coupled solid state relays that are rated for 0.12 A at 50 V DC. Each set point has hysteresis characteristics and consists of two set values: upper threshold and lower threshold. LEDs on the front panel display the status of each set point. The high and low threshold values of each of the three set points can be set independently. Related Products MM200 Vacuum Sensor Controller - The MM200 controls any Televac vacuum sensor including cold cathode, convection, diaphragm, hot ion, and thermocouple sensors. It also has optional features including up to 8 relay set points and RS-232/RS-485 communications. The large, bright LED display makes it easy to read from a distance. The MM200 is a modular unit, allowing customers to choose a vacuum sensing solution specific to their needs. Visit the Televac website at www.televac.com for a full list of products and product applications. email: sales@frederickscompany.com tel: +1 215 947 2500 CC-10 Part Number Vacuum Fittings NW25 (DN25 ISO-KF) NW40 (DN40 ISO-KF) 2.75” CF (DN40 ISO-CF-M) CC-10 Cable 10 ft 20 ft 35 ft 50 ft (90 to 240) V AC / 24 V DC CE Power Supply (90 to 240) V AC / 24 V DC CE Power Supply with International Plug Adapters Replacement Anode Assembly Replacement O-Ring for Anode Assembly Remote Display Module 2-7980-0XX XX 31 32 52 2-9858-0XX 10 20 35 50 2-7900-097 2-7900-101 2-7900-099 6-4210-260 2-7900-098 Contact Us Televac The Fredericks Company 2400 Philmont Avenue Huntingdon Valley, PA 19006 tel: +1 215 947 2500 email: sales@televac.com web: www.televac.com Disclaimer: Specifications subject to change without notice. The Fredericks Company assumes no responsibility for inaccuracies in product specifications or any liability arising from product use. © 2015 The Fredericks Company web: frederickscompany.com form: cc10_ds rev D page: 2/2
2-7980-031 价格&库存

很抱歉,暂时无法提供与“2-7980-031”相匹配的价格&库存,您可以联系我们找货

免费人工找货