0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EA5R450XKQ

EA5R450XKQ

  • 厂商:

    BANNER

  • 封装:

    -

  • 描述:

    EZ-ARRAY 5MM OPTICAL SPACING X 4

  • 数据手册
  • 价格&库存
EA5R450XKQ 数据手册
A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Instruction Manual Original Instructions 157954 Rev. C 16 May 2017 © Banner Engineering Corp. All rights reserved 157954 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Contents 1 Features 2 Overview .......................................................................................................................................................................... 4 ......................................................................................................................................................................... 5 2.1 System Components ..............................................................................................................................................................................6 2.2 Features ................................................................................................................................................................................................. 6 2.3 Configuration via DIP Switch or IO-Link Interface .................................................................................................................................. 6 2.3.1 Outputs ..................................................................................................................................................................................... 7 2.3.2 Display Invert ............................................................................................................................................................................ 7 2.4 Status Indicators .................................................................................................................................................................................... 7 2.4.1 Zone Indicators (Beams Blocked Segment) .............................................................................................................................. 7 2.4.2 Three-Digit Display ................................................................................................................................................................... 7 2.4.3 Blanking Indicator ..................................................................................................................................................................... 8 ............................................................................................................................................8 2.4.4 Electronic Configuration Indicator 2.4.5 Receiver Interface Status Indicators ......................................................................................................................................... 8 2.5 Receiver Gray (Remote Teach) Wire ..................................................................................................................................................... 8 2.6 Scanning Method .................................................................................................................................................................................. 9 2.6.1 Straight Scan ........................................................................................................................................................................... 10 2.6.2 Single-Edge Scan ..................................................................................................................................................................... 10 2.6.3 Double-Edge Scan ................................................................................................................................................................... 10 2.6.4 Maximum Scan Times .............................................................................................................................................................11 ............................................................................................................................................................................... 11 2.7 Gain Configuration .............................................................................................................................................................. 12 2.8 Electronic Alignment Routine 2.9 Blanking ............................................................................................................................................................................................... 12 .......................................................................................................................................................... 12 2.10 Measurement Mode Selection 2.11 Analog Output Configuration ............................................................................................................................................................ 13 .......................................................................................................................................................... 14 2.12 Discrete Output Configuration 3 Components and Specifications ..................................................................................................................................... 15 3.1 Sensor Models ..................................................................................................................................................................................... 15 ................................................................................................................................................................... 15 3.2 Cordsets and Connections 3.3 Alignment Aids ..................................................................................................................................................................................... 17 ........................................................................................................................................... 17 3.4 Accessory Mounting Brackets and Stands 3.5 Replacement Parts .............................................................................................................................................................................. 18 .......................................................................................................................................................................................18 3.6 Specifications 3.7 Emitter and Receiver Dimensions ....................................................................................................................................................... 19 3.8 Standard Bracket Dimensions ............................................................................................................................................................. 20 4 Installation and Alignment .............................................................................................................................................21 4.1 Mounting the Emitter and Receiver .................................................................................................................................................... 21 4.2 Mechanical Alignment ......................................................................................................................................................................... 21 4.3 Wiring Diagrams .................................................................................................................................................................................. 22 ................................................................................................................................................................................ 23 4.4 Optical Alignment 5 Receiver User Interface ..................................................................................................................................................25 5.1 Configuration DIP Switches ................................................................................................................................................................. 25 5.1.1 Scanning Modes (S1 and S2) .................................................................................................................................................. 25 5.1.2 Measurement Modes (S3 and S4) .......................................................................................................................................... 26 5.1.3 Analog Slope (S5) .....................................................................................................................................................................26 5.1.4 Complementary/Alarm (S6) ................................................................................................................................................... 26 ............................................................................................................................ 26 5.2 Alignment/Blanking Button (Electronic Alignment) 5.2.1 Electronic Alignment and Blanking - Receiver Interface ........................................................................................................ 26 5.2.2 Flashing "000" on the 3-Digit Display ..................................................................................................................................... 27 ...........................................................................................................................................................27 5.3 Gain (Sensitivity Adjust) Button 5.4 Inverting the 3-Digit Display ................................................................................................................................................................ 27 ....................................................................................................................................................... 27 5.5 Troubleshooting and Error Codes 5.5.1 "Dirty" Channel Indicator ....................................................................................................................................................... 27 6 IO-Link Interface ............................................................................................................................................................ 28 6.1 Overview ............................................................................................................................................................................................. 28 6.2 IO-Link Profile and Models ................................................................................................................................................................... 28 6.3 Hardware Interface ............................................................................................................................................................................. 28 6.3.1 Electrical Interface .................................................................................................................................................................. 29 6.3.2 IO-Link Master ........................................................................................................................................................................ 29 ....................................................................................................................................................... 29 6.4 IODD (IO-Link Device Description) 6.5 Configuration Data .............................................................................................................................................................................. 29 ................................................................................................................................................................. 29 6.5.1 Scan Configuration 6.5.2 Blanking Configuration ........................................................................................................................................................... 30 ............................................................................................................................................................ 31 6.5.3 General Configuration A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 6.5.4 Analog Output 1 Configuration .............................................................................................................................................. 33 6.5.5 Analog Output 2 Configuration .............................................................................................................................................. 34 6.5.6 Discrete Output 1 Configuration ............................................................................................................................................ 34 6.5.7 Discrete Output 2 Configuration ............................................................................................................................................ 35 6.6 System Status and Measurement Data ................................................................................................................................................ 35 6.6.1 Active Measurements .............................................................................................................................................................35 6.6.2 ALL Measurements ................................................................................................................................................................. 36 6.6.3 Channel States ........................................................................................................................................................................ 37 6.6.4 System Info and Status ........................................................................................................................................................... 37 .......................................................................................................................................... 39 6.6.5 Receiver and Emitter Version Info 6.6.6 Communications Version Info ................................................................................................................................................ 39 .................................................................................................................................................. 39 6.6.7 Alignment/Blanking Routine 7 Banner Engineering Corp Limited Warranty 7.1 Contact Us ................................................................................................................... 41 ........................................................................................................................................................................................... 41 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 1 Features • • • • • • • • • A cost-effective, two-piece measuring light curtain designed for quick and simple installations with the sophistication to handle the toughest sensing applications Excels at high-speed, precise process monitoring and inspection, profiling, and web-guiding applications A comprehensive combination of scanning options: ◦ 14 measurement (“scan analysis”) modes ◦ 3 scanning methods ◦ Selectable beam blanking ◦ Selectable continuous or gated scan initiation ◦ Selectable threshold setting for semi-transparent applications ◦ 2 analog outputs, 2 discrete outputs ◦ Communication interface via IO-Link Outstanding 4 meter range with 5 mm beam spacing Available in 12 lengths from 150 mm to 2400 mm Excellent 5 mm minimum object detection or 2.5 mm edge resolution, depending on scanning method Receiver user interface for quick, intuitive setup of many common applications: ◦ 6-position DIP switch for setting scan mode, measurement mode, analog slope, discrete output 2 option (complementary measurement or alarm operation) ◦ 2 push buttons for gain method selection and alignment/ blanking ◦ 7 Zone LEDs for instant alignment and beam blockage information ◦ 3-digit display for sensing information and diagnostics Advanced configuration via IO-Link communication interface Remote teach wire option for alignment, gain settings, inverted display, and DIP switch disable WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. 4 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 2 Overview The A-GAGE® EZ-ARRAY™ measuring light screen is ideal for such applications as on-the-fly product sizing and profiling, edge-guiding and center-guiding, loop tensioning control, hole detection, parts counting, and similar uses. Emitters and receivers are available with arrays from 150 to 2400 mm (5.9 in to 94.5 in) long. The emitter has a column of infrared light emitting diodes (LEDs) spaced 5mm apart; their light is collimated and directed toward the receiver, positioned opposite the emitter, which has photodiodes on the same 5 mm pitch. The light from each emitter LED is detected by the corresponding receiver photodiode. This sophisticated light curtain is capable of detecting opaque cylindrical objects as small as 5mm in diameter or measuring part edges within 2.5 mm, depending on the scanning method selected (see Scanning Method). The sensing range is 400 mm to 4 m (16 in to 13 ft). The EZ-ARRAY’s two-piece design makes it economical and easy to use. Controller functionality is built into the receiver housing. It can be configured for many straightforward applications simply by configuring the six-position DIP switch on the front of the receiver (the receiver user interface).The IO-Link communication interface provides the capability for more advanced control and monitoring. See IOLink Interface. Installation is easy, too. The emitter and receiver housings can be side-mounted or end-cap-mounted using the included end-cap brackets; longer models also include a center bracket (see Mounting the Emitter and Receiver). Beam synchronization is achieved via the 8-conductor sensor cables. Individual LEDs and a 3-digit diagnostic display on the receiver provide ongoing visual sensing status and diagnostic information. Comprehensive data is available to a process controller via a combination of four outputs: two analog and two discrete (discrete output 1 is an IO-Link output). The IO-Link output provides a discrete output (SIO mode) or a communication interface (IO-Link mode). www.bannerengineering.com - Tel: 763.544.3164 5 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 2.1 System Components A typical A-GAGE EZ-ARRAY has four components: an emitter and a receiver, each with an integral quick-disconnect (QD) fitting, plus an 8pin QD cordset for the emitter and for the receiver. For applications that use the IO-Link interface, an additional cable splitter is used to convert the receiver 8-pin connector to a compatible M12 connector. 2.2 Features Built-in diagnostic programming and easy-to-see indicators on the receiver simplify physical alignment and troubleshooting; more advanced diagnostics are available via the IO-Link interface. Emitter Receiver Under Hinged Access Panel: Zone Indicators The receiver has a bright LED that indicates overall sensing status (OK, marginal alignment, and hardware error). Two other LEDs indicate serial communication status. Seven Zone indicators each communicate the blocked / aligned status of one-seventh of the total array. A 3-digit diagnostic display provides further diagnostic information, including number of beams blocked, whether blanking is configured, and troubleshooting codes. 3-Digit Diagnostic Display Alignment/Blanking Push Button Power ON LED Gain (Sensitivity Adjust) Push Button Beam #1 (Closest to Display) 6-Position Configuratio n DIP Switch Status, Communication Active, and Communication Error LEDs Screw-on Security Plate limits access to DIP switch and push buttons The emitter has a red LED that signals proper operation (ON when power is applied). See Status Indicators for more information about indicators and Troubleshooting and Error Codes for display codes and troubleshooting. The Alignment routine (Alignment Blanking Button or Alignment Blanking Routine ) automatically equalizes the excess gain of each beam for reliable object detection throughout the array. This routine need not be performed again unless the sensing application changes, or if the emitter and/or receiver is moved. Configurable beam blanking accommodates machine components and fixtures that must remain in or move through the light screen. Blanking may be set using the receiver interface, the teach wire, or the IO-Link interface. The EZ-ARRAY light screen provides a wide selection of sensing and output options, including measurement (“scan analysis”) modes and scanning methods that can determine a target object’s location, overall size, total height, or total width, or the number of objects. Scanning may be continuous or controlled by a gate sensor. 2.3 Configuration via DIP Switch or IO-Link Interface Commonly used configuration options can be set up easily via a six-position DIP switch located behind a hinged clear access panel on the front of the receiver. Access to the DIP switch can be prevented by using the screw-on security plate to hold the clear access panel closed or by disabling them via the IO-Link interface. 6 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 2.3.1 Outputs All models have two analog outputs and two discrete outputs (discrete output 1 is an IO-Link output). The analog outputs are 0–10V voltage. They may be configured (via DIP switch or IO-Link interface) for either a positive or negative slope. Discrete output 1 is always used for measurement; discrete output 2 may be used either for alarm or measurement operation (selectable via DIP switch or IO-Link interface). When the receiver interface is used, discrete output 1 and analog output 1 follow the same measurement mode. When the IO-Link interface is used for configuration, discrete output 2 has full configurability, including measurement mode, NPN or PNP polarity, and normally open or normally closed operation. Discrete output 1 has the same configurability as discrete output 2, except for NPN or PNP polarity. Discrete output 1 is a dedicated push-pull output. 2.3.2 Display Invert For applications where the sensors must be mounted with the display end at the top (so that the display is not right-reading), the receiver’s diagnostic display can be inverted for easy reading, either by use of the receiver’s remote wire (Receiver Gray (Remote Teach) Wire) or the IO-Link interface (HW Interface Flags in Appendix: General Configuration). 2.4 Status Indicators Both the emitter and receiver provide ongoing visual indication of operating and configuration status. The emitter has a red LED that signals proper operation (ON when power is applied). The receiver has a bright Status LED that indicates overall sensing status (OK, marginal alignment, and hardware error). Two other LEDs indicate whether communication is active or if there is an error. Seven Zone indicators each communicate the blocked/aligned status of one-seventh of the total array. A 3-digit diagnostic display provides further diagnostic information: number of beams blocked, whether blanking is configured, and troubleshooting codes. See Troubleshooting and Error Codes for display codes and troubleshooting. Emitter LED Status LED Color Description Red ON Status OK Red Flashing at 1 Hz Error Receiver LED Color Description Red Blocked channels within the zone Green All channels are clear within the zone Red Hardware Error or marginal alignment Green Status OK 3-digit 7-segment Measurement Mode/Diagnostic Indicator COMM LED Yellow flashing IO-Link mode 3-digit 7-segment Measurement Mode/Diagnostic Indicator ERROR LED Red On Error 7 Zone Indicators 3-digit 7-segment Measurement Mode/Diagnostic Indicator Status LED 2.4.1 Zone Indicators (Beams Blocked Segment) Seven LEDs represent emitter/receiver alignment status. They provide a visual aid for sensor alignment and monitoring objects within the sensor’s field of view. The sensor array is partitioned into seven equal segments, each of which is represented by one of the seven LEDs. The LED closest to DIP switch S6 (see Configuration DIP Switches on page 25) represents the group of optical channels closest to the receiver display (the “bottom” group). The LED closest to DIP switch 1 represents the far segment of channels. These LEDs illuminate either green or red. When an LED is green, no unblanked beams are obstructed in that segment. When the LED is red, one or more beams in that segment is obstructed. 2.4.2 Three-Digit Display The 3-digit display has slightly different functions during normal operation, alignment, and gain adjust modes. In normal operation the display indicates the current numerical value of measurement mode 1. The display also identifies the following activated sensor functions: blanking and locked-out user interface/electronic configuration, as shown in Electronic Configuration Indicator on page 8. (For directions for inverting the display, see Receiver Gray Wire or see HW Interface Flags in General Configuration.) During blanking mode, the display reads “n”, followed by the number of blocked beams in the array. During alignment mode, it reads “A”, followed by the number of blocked, unblanked beams; a period follows the A (“A.”) if blanking is configured. www.bannerengineering.com - Tel: 763.544.3164 7 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual During gain adjust mode, the display reads “ L ” followed by “1” or “2” to indicate the gain level. (A “1” represents high excess gain, and a “2” represents low contrast.) If a sensing error occurs, the display reads “c” followed by a number that corresponds to the recommended corrective action (see Troubleshooting and Error Codes). 2.4.3 Blanking Indicator The Blanking indicator will be visible (ON) when the blanking feature is enabled. It appears as a period following the first digit of the display. 2.4.4 Electronic Configuration Indicator The Electronic Configuration indicator is ON when the sensor configuration is defined by the IO-Link interface, and not the DIP switch. When electronic configuration is enabled, the DIP switch is ignored. ‘A’ in this position indicates Alignment mode Period ON indicates Blanking Configured Period ON indicates Electronic Configuration Enabled 2.4.5 Receiver Interface Status Indicators The receiver has three status indicators: green/red STATUS, yellow COMM, and red ERROR. The following table lists the indicator states. LED Indicator STATUS Color Explanation Green System is OK Red Marginal Alignment or Hardware Error; check 3-digit display* COMM Yellow IO-Link Mode - Indicator is flashing ERROR Red Error: Check cabling or master controller *Display shows “c”: See Troubleshooting and Error Codes. Display shows only numbers: Low Gain/Marginal Alignment condition. See Troubleshooting and Error Codes. 2.5 Receiver Gray (Remote Teach) Wire The receiver gray (remote teach) wire is used to electronically emulate the receiver push button functions (see Troubleshooting and Error Codes) via a process controller, to disable the DIP switches for security, or to provide a gate input to initiate sensor scanning. Connect a normally open switch between the receiver's gray wire and dc common, or connect the gray wire to a digital input (PLC) and pulse the wire as indicated in Receiver Interface Status Indicators on page 8. Note: A low level is 0 to 2 volts and a high level is 10 to 30 volts or circuit open. Input impedance is 22k. Remote TEACH/Gate in the determines the functionality of the receiver gray wire (see Remote TEACH/Gate in Scan Configuration ). • Disabled: The remote wire has no function (regardless of whether it is low or high). When the gray wire is disabled, the receiver is in continuous scan mode; it begins a new scan immediately after updating the outputs from the previous scan. (Continuous scan is used in most analog output applications and whenever continuous updating of the outputs is acceptable.) The gray wire is always enabled when in DIP switch mode. • Remote Teach: The gray wire provides the full Remote Teach functionality shown in Receiver Interface Status Indicators on page 8. • Alignment/Sensitivity: This mode is an abbreviated version of Remote Teach. It can perform the alignment and sensitivity adjustment functions, but not the display inversion or DIP switch enable/disable functions. Gate Mode options enable the gray wire to be wed as a gate input pulse, typically from a dc device such as an NPN-output photoelectric sensor or a PLC discrete output. • Gate - Active High - The receiver scans whenever the gate is pulled high. • Gate - Active Low - The receiver scans whenever the gate is pulled low. • Gate - Rising Edge - The receiver scans once for each low-to-high gate transition. (Multiple transitions cannot be faster than the sensor's response for them to be reliably detected.) 8 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual • Gate - Falling Edge - The receiver scans once for each high-to-low gate transition. (Multiple transitions cannot be faster than the sensor's response for them to be reliably detected.) Process Alignment / Blanking Remote Wire Procedure 0.05 ≤ sec. T ≤ 0.8 sec. Access Alignment Mode Result "A" appears on 3-digit display 1X Access Blanking Mode From Alignment Mode: "n" appears on 3-digit display, along with number of blocked beams 2X Exit Blanking Mode "A." appears on 3-digit display (sensor returns to alignment mode with blanking enabled) 1X Exit Alignment Mode Sensor returns to run mode 1X Process Gain Method Remote Wire Procedure 0.05 ≤ sec. T ≤ 0.8 sec. Access Gain Mode From Run Mode: Result "L" appears on 3-digit display, along with number "1" or "2", to designate gain level 2X Toggle Between Gain Settings Save Gain Level and Exit Number changes from number "1" to "2", back to "1", etc. 1X When correct level is displayed: 2X Invert Display Invert Display Display inverts from previous state; sensor continues in run mode 3X Receiver Interface Enable/Disable Receiver Interface Enable/ Disable Gain level is configured: "1" = High-excess-gain setting "2" = Low-contrast setting Sensor returns to run mode The factory default is Receiver Interface enabled. 4X Four-pulsing the remote line saves the current settings and disables the interface (the sensor continues to operate using the saved settings; changes made to the DIP switch will have no effect). Repeating the process enables the Receiver Interface so that settings can be changed. 2.6 Scanning Method One of three scanning methods may be configured: • Straight Scan • Single-edge Scan • Double-edge Scan (1, 2, 4, 8, 16, or 32 steps) Sensor response time is a function of sensor length and scanning method. Maximum scan times are shown in Maximum Scan Times on page 11. www.bannerengineering.com - Tel: 763.544.3164 9 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Scanning Method Straight Scan LowContrast High-ExcessGain Minimum Object Detection Size* 5 mm (0.2 in) 10 mm (0.4 in) Edge Resolution 5mm (0.2 in) 5mm (0.2 in) Single-Edge Scan Double-Edge Scan (per Edge) Step Size (Number of Beams) 1 2 4 8 16 32 10mm (0.4 in) 10mm (0.4 in) 20mm (0.8 in) 30mm (1.2 in) 50mm (2 in) 90mm (3.6 in) 170mm (6.8 in) 2.5mm (0.1 in) 2.5mm (0.1 in) 2.5mm (0.1 in) 2.5mm (0.1 in) 2.5mm (0.1 in) 2.5mm (0.1 in) 2.5mm (0.1 in) *MODS determined using a rod target object 2.6.1 Straight Scan Straight Scan is the default mode, in which all beams are scanned in sequence, from the display end to the far end of the array. This scanning method provides the smallest object detection size. Straight scan is used when low-contrast sensitivity is selected or when single-edge and double-edge scan cannot be used. The edge resolution is 5 mm (0.2 in). When low-contrast sensing is selected (used when measuring semi-transparent objects), the minimum object detection size is 5 mm (0.2 in) diameter. When high-excess-gain sensing is selected, the minimum object detection size is 10 mm (0.4 in). 2.6.2 Single-Edge Scan Single-Edge Scan is used to measure the height of a single object. This scanning method is commonly used for box height measurement. For single-edge scan, the receiver always activates the first beam channel (or "bottom" beam, nearest the display). When the first beam is blocked, the sensor performs a binary search to hunt for the last beam blocked, as follows: 1. The receiver scans only the first beam until it is blocked. 2. When the first beam is blocked, the sensor looks to see whether the middle beam is blocked or made (unblocked). 3. If the middle beam is made (unblocked), the sensor checks the bottom quarter beam; if the middle beam is blocked, the sensor checks the top quarter beam. 4. The routine continues to divide the number of beams in half until the edge is found. Single-edge scan can be used only for single, solid objects that block the first beam (closest to the display). Because the receiver checks only the first beam until it is blocked, single-edge scan will not function when the item to be measured does not block the first beam. Single-edge scan is also ineffective if the object does not present a continuous blocked pattern. Single-edge scan works only when the high-excess-gain setting is enabled. When single-edge scan is selected, the sensor object detection size is 10 mm and edge resolution is 2.5 mm. 2.6.3 Double-Edge Scan Double-Edge Scan is used to detect two edges of a single object, for example, to determine box width measurements. Double-edge scan requires the selection of a step size: 1, 2, 4, 8, 16 or 32 beams. The sensor uses the steps to "skip" over beams, as follows: 1. The sensor activates beam 1 (closest to the sensor display end). 2. The sensor activates the next beam, determined by the step size. (For example, if the step size is 2, beam 3 is next; if the step size is 8, beam 9 is next.) 3. As long as the activated beam is made (unblocked), the sensor continues the stepping routine until a blocked beam is found. 4. When a blocked beam is found, a binary search is conducted to find the object's "bottom" edge. 5. When the bottom edge is found, the sensor continues to step through the array until it finds the next unblocked beam. 6. Another binary search is performed to find the second edge. Similar to single-edge scan, double-edge scan has some restrictions: the object should provide a solid obstruction; the size of the object determines the maximum step size. Double-edge scan can be used to detect up to three objects. Like single-edge scan, double-edge scan works only when the high-excess-gain setting is selected. When double-edge scan is selected, the sensor object detection size varies, depending on the step size, but edge resolution is 2.5 mm. 10 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Step #1 Step #2 Beam #1 of 30 blocked Step #3 Beam #15 blocked Beam #23 clear Emitter Receiver Step #4 Step #5 Beam #17 blocked Step #6 Beam #19 clear Beam #18 blocked 2.6.4 Maximum Scan Times Maximum Scan Times (in milliseconds) Array Length Straight Scan Single-Edge Scan Double-Edge Scan Step 1 Beam Step 2 Beams Step 4 Beams Step 8 Beams Step 16 Beams Step 32 Beams 150 mm (5.9 in) 2.8 1.5 3.4 2.8 2.5 2.4 1.9 N/A 300 mm (11.8 in) 5.0 1.5 5.9 4.1 3.2 2.8 2.3 2.1 450 mm (17.7 in) 7.1 1.6 8.5 5.5 4.2 4.0 3.2 2.5 600 mm (23.6 in) 9.3 1.6 11.0 6.8 4.9 4.2 4.0 2.8 750 mm (29.5 in) 11.4 1.7 13.5 8.1 5.7 4.6 4.5 4.5 900 mm (35.4 in) 13.6 1.7 16.0 9.5 6.1 4.7 4.6 4.6 1050 mm (41.3 in) 15.7 1.8 18.6 10.8 6.8 5.2 4.8 4.8 1200 mm (47.2 in) 17.9 1.8 21.1 12.2 7.4 5.5 4.9 4.9 1500 mm (59.1 in) 22.2 1.9 26.1 14.8 9.0 6.4 5.3 4.9 1800 mm (70.9 in) 26.5 2.0 31.2 17.5 10.5 7.3 6.0 5.6 2100 mm (82.7 in) 30.8 2.8 36.3 20.2 12.0 8.2 6.7 5.6 2400 mm (94.5 in) 35.1 2.8 41.4 22.9 13.5 9.1 7.4 5.9 Scan times are also dependent on analog filter speed; see Analog Output 1 Configuration and Analog Output 2 Configuration. 2.7 Gain Configuration The EZ-ARRAY provides two gain options for straight scan applications: high excess gain and low contrast. The gain method can be selected using the receiver push button, the receiver remote teach wire, or the IO-Link interface. High (maximized) excess gain is suited for detecting opaque objects and for reliable sensing in dirtier environments where objects to be detected are 10 mm or larger. The high excess gain method is always used in single- and double-edge scan. The high excess gain option has a minimum blocked threshold level, which provides reliable sensing at higher excess gain levels. The low-contrast setting is used for sensing semi-transparent materials and for detecting objects as small as 5 mm (straight scan only). In low-contrast operation, only a portion of a beam must be blocked for detection to occur. In low-contrast operation, the sensor sets an individual threshold for each optical channel during the alignment process; this process equalizes the signal strength to allow semitransparent object detection. www.bannerengineering.com - Tel: 763.544.3164 11 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual When using the IO-Link interface, low-contrast sensing provides a fine-tune sensitivity setting of 15% to 50%. When using the receiver interface, low-contrast sensitivity is always 30%. Gain Setting Scan Method EZ-ARRAY MODS 1 EZ-ARRAY Resolution Low Contrast Straight Scan 5 mm 5 mm Single-edge Scan - - Double-edge Scan - - Straight Scan 10 mm 5 mm Single-edge Scan 10 mm 2.5 mm Double-edge Scan Depends on step size 2.5 mm / edge 5 mm total (both edges) High Excess Gain 2.8 Electronic Alignment Routine The objective of the optical alignment process is to adjust the emitter light level to maximize sensor performance. Perform the alignment procedure at installation and again whenever the emitter and/or receiver is moved. During the alignment procedure, the receiver polls each beam channel to measure excess gain and performs a gain adjustment for each beam. When the system exits the alignment procedure, each channel's signal strength is stored in non-volatile memory. The procedure can be performed using the receiver remote wire, the receiver interface push button or the IO-Link interface (see Receiver Gray Wire, Alignment/Blanking Button, or refer to Alignment Blanking Routine). The receiver's Alignment push button may be disabled, by configuration thru the IO-Link interface. 2.9 Blanking If a machine fixture or other equipment blocks one or more sensing beams, the affected beam channels may be blanked. The blanking option causes the receiver to ignore the status of blanked beams for measurement mode calculations. For example, if a machine fixture blocks one or more beams during sensing, the output data will be incorrect; if the beams blocked by the fixture are blanked, the output data will be correct. Blanking may be configured using the receiver's Alignment push button, the receiver remote wire, or the IO-Link interface. 2.10 Measurement Mode Selection The outputs may be configured for any of fourteen measurement (scan analysis) modes, which refer to specific beam locations, quantities of beams, or edge transitions. Note that not all measurement mode options are available when the receiver interface is used for configuration. Selected modes are individually assigned to each output (see Configuration DIP Switch or refer to Measurement 1 and Measurement 2 table in General Configuration). When using the IO-Link interface for configuration, discrete output 2 can have NPN or PNP polarity (regardless of model), be normally open or normally closed, and be assigned to any of the measurement modes. Discrete output 1 has the same configuration options as discrete output 2, except for NPN or PNP polarity. Discrete output 1 is the IO-Link output and is a dedicated push-pull output. When using the receiver interface, limited output configuration combinations may be selected see (Configuration DIP Switch). Note: Array beams are numbered in sequence (beam 1 located nearest the sensor display). The "first beam" referenced in the following descriptions is the beam nearest the sensor display. 1 MODS: Minimum Object Detection Size 12 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual "Beam Location" Modes First Beam Blocked (FBB) The location of the first blocked beam. First Beam Made (FBM) The location of the first made (unblocked) beam. Last Beam Blocked (LBB) The location of the last blocked beam. Last Beam Made (LBM) The location of the last made beam. Middle Beam Blocked (MBB) The location of the beam midway between the first and last blocked beams. Receiver Emitter Last Beam Made (LBM) First Beam Made (FBM) 60 50 40 30 20 In First Beam Made mode, first beam is #40 of 60 10 Receiver "Beam Total" Modes Total Beams Blocked (TBB) The total number of blocked beams. Total Beams Made (TBM) The number of beams made. Emitter Last Beam Blocked (LBB) First Beam Blocked (FBB) 60 50 Contiguous Beams Blocked (CBB) The largest number of consecutively blocked beams. In Last Beam Made mode, last beam is #50 of 60 40 30 20 Receiver Contiguous Beams Made (CBM) The largest number of consecutively made beams. Outside Dimension (OD) The inclusive distance (measured in beams) from the first blocked beam to the last blocked beam. Inside Dimension (ID) The number of made beams, between the first and last blocked beams. Transitions (TRN) The number of changes from blocked to clear status and from clear to blocked status. (If beams 6-34 are blocked, then there is a clear-to-blocked transition from beam 5 to bream 6, and a blocked-to-clear transition from beam 34 to beam 35.) Transition mode can be used to count objects within the array. Contiguous First Beam Blocked (CFBB) The location of the first blocked beam in the largest group of adjacent blocked beams. Contiguous Last Beam Blocked (CLBB) The location of the last blocked beam in the largest group of adjacent blocked beams. Carpet Nap and Carpet Edge These measurement modes are used to measure the location of carpet backing and tuft, and are selectable only via the IO-Link interface, and only when the Scan Type Carpet Nap is selected. The modes can be measured from either end of the sensor, but at least 10 beams (2 in) must be blocked from one edge. In Last Beam Blocked mode, last beam is #55 of 60 In First Beam Blocked mode, first beam is #20 of 60 10 Emitter Total Beams Made (TBM) Total Beams Blocked (TBB) 60 50 40 30 20 10 In Total Beams Made mode, 38 of 60 possible beams are made In Total Beams Blocked mode, 22 of 60 possible beams are blocked 2.11 Analog Output Configuration Analog output configuration assigns analog outputs 1 and 2 to one of the measurement modes described in Measurement Mode Selection. When the selected measurement mode involves first or last beam blocked or made (unblocked), the assigned output will vary in proportion to the beam number identified during a scan. When the measurement mode involves total beams blocked or made, that assigned output will vary in proportion to the total beams counted during a scan. Analog outputs may have Null and Span values set in the IO-Link interface, in addition to a filter setting (to smooth the output) and Zero Value (to specify the output value when the measurement mode value is zero). Refer to Appendix: Analog Output 1 Configuration and Analog Output 2 Configuration. www.bannerengineering.com - Tel: 763.544.3164 13 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 2.12 Discrete Output Configuration Discrete Output 1; Receiver Interface When the receiver interface is used for configuration, the measurement mode assigned to discrete output 1 is the same as that assigned to analog output 1. Discrete Output 2; Receiver Interface Discrete output 2 (only) has two options: alarm and complementary (measurement) operation. Alarm—Output 2 energizes when the receiver detects a sensor error (such as a disconnected cable) or whenever the excess gain of one or more beams becomes marginal. Complementary (Measurement)—Discrete output 2 operation is complementary to discrete output 1 (when output 1 is ON, output 2 is OFF, and vice versa). Discrete Output 1 and 2 Configuration; IO-Link Interface When the IO-Link interface is used for configuration, the discrete outputs have more options: either discrete output can be assigned to any of the measurement modes, high and low set points can be added, the outputs can be inverted, and hysteresis values can be set, as well as a scan number to smooth output performance. Discrete output 2 can be assigned to alarm mode via the IO-Link interface also. Refer to Appendix: Discrete Output 1 Configuration and Discrete Output 2 Configuration. 14 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 3 Components and Specifications 3.1 Sensor Models Discrete Output 2 Analog Output Array Length Y 3 Total Beams EA5E150Q Emitter EA5R150XKQ Receiver PNP Voltage (0-10V) 150mm (5.9 in) 30 EA5E300Q Emitter EA5R300XKQ Receiver PNP Voltage (0-10V) 300mm (11.8 in) 60 EA5E450Q Emitter EA5R450XKQ Receiver PNP Voltage (0-10V) 450mm (17.7 in) 90 EA5E600Q Emitter EA5R600XKQ Receiver PNP Voltage (0-10V) 600mm (23.6 in) 120 EA5E750Q Emitter EA5R750XKQ Receiver PNP Voltage (0-10V) 750mm (29.5 in) 150 EA5E900Q Emitter EA5R900XKQ Receiver PNP Voltage (0-10V) 900mm (35.4 in) 180 EA5E1050Q Emitter EA5R1050XKQ Receiver PNP Voltage (0-10V) 1050mm (41.3 in) 210 EA5E1200Q Emitter EA5R1200XKQ Receiver PNP Voltage (0-10V) 1200mm (47.2 in) 240 EA5E1500Q Emitter EA5R1500XKQ Receiver PNP Voltage (0-10V) 1500mm (59.1 in) 300 EA5E1800Q Emitter EA5R1800XKQ Receiver PNP Voltage (0-10V) 1800mm (70.9 in) 360 EA5E2100Q Emitter EA5R2100XKQ Receiver PNP Voltage (0-10V) 2100mm (82.7 in) 420 EA5E2400Q Emitter EA5R2400XKQ Receiver PNP Voltage (0-10V) 2400mm (94.5 in) 480 Emitter/Receiver Model IO-Link 3.2 Cordsets and Connections 8-Pin Threaded M12/Euro-Style Cordsets with Shield Model Length MAQDC-806 1.83 m (6 ft) MAQDC-815 4.58 m (15 ft) MAQDC-830 9.14 m (30 ft) Style Dimensions 2 1 7 6 44 Typ. Straight M12 x 1 ø 14.5 MAQDC-850 Pinout (Female) 15.2 m (50 ft) 1 = White 2 = Brown 3 = Green 4 = Yellow 3 4 8 5 5 = Gray 6 = Pink 7 = Blue 8 = Red 2 Discrete Output 1 is push-pull (IO-Link) 3 Models with array lengths 1050mm and longer ship with a center bracket as well as two end-cap brackets. www.bannerengineering.com - Tel: 763.544.3164 15 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 8-Pin Threaded M12/Euro-Style Cordsets―Double Ended Model (8-pin/8-pin )4 Length DEE2R-81D 0.31 m (1 ft) DEE2R-83D 0.91 m (3 ft) DEE2R-88D 2.44 m (8 ft) DEE2R-815D 4.57 m (15 ft) DEE2R-825D 7.62 m (25 ft) DEE2R-850D 15.2 m (50 ft) Style Dimensions Female 2 8 1 44 Typ. 2 3 4 22.9 m (75 ft) 1 = White 2 = Brown 3 = Green 4 = Yellow 30.5 m (100 ft) IO-Link Cable Splitters Model Length Description 0m 8-pin female to split 5-pin male and 8-pin female, Eurostyle, straight, with shield (IO-Link pin 2 is Voltage Output 1) 0m 8-pin female to split 5-pin male and 8-pin female, Eurostyle, straight, with shield (IO-Link pin 2 is Discrete Output 2) CSB-M1250M1280 CSB-M1240M1280* * Shipped with all EZ-ARRAY IO-Link receivers 4 Standard cordsets are yellow PVC with black overmold. For black PVC and overmold, add suffix "B" to model number (example, DEE2R-81DB) 16 www.bannerengineering.com - Tel: 763.544.3164 5 Male M12 x 1 ø 14.5 M12 x 1 ø 14.5 DEE2R-8100D 3 4 1 7 6 40 Typ. Female Straight/ Male Straight DEE2R-875D Pinout 7 6 8 5 5 = Gray 6 = Pink 7 = Blue 8 = Red A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 3.3 Alignment Aids Model Description LAT-1-SS Self-contained visible-beam laser tool for aligning any EZ-ARRAY emitter/receiver pair. Includes retroreflective target material and mounting clip. EZA-LAT-SS Replacement adaptor (clip) hardware for EZ-ARRAY models EZA-LAT-2 Clip-on retroreflective LAT target BRT-THG-2-100 2-inch retroreflective tape, 100 ft BT-1 Beam Tracker 3.4 Accessory Mounting Brackets and Stands See Replacement Parts for standard brackets. Order one EZA-MBK-20 bracket per sensor, two per pair. EZA-MBK-20 • Adapter brackets for mounting to engineered/slotted aluminum framing such as 80/20™ and Unistrut™. Angled slots allow mounting to 20 mm to 40 mm dual channel and center slot. allows mounting to single channel framing • Retrofit for Banner MINI-SCREEN® • Order EZA-MBK-20U for bracket with M5 and M6 mounting hardware Note: Standard brackets shipped with sensors connect directly to MSA series stand, using hardware included with the stands. Hole center spacing: A = 44.4, B = 20, C = 40 Hole size: A = 10.2 × 4.8; B , C = 25 × 7; D = ø 21.5 MSA Series Stands (Base Included)* Stand Model Useable Stand Height Overall Stand Height MSA-S24-1 483 mm (19") 610 mm (24") MSA-S42-1 940 mm (37") 1067 mm (42") MSA-S66-1 1549 mm (61") 1676 mm (66") MSA-S84-1 2007 mm (79") 2134 mm (84") Dimensions *Available without a base by adding suffix NB to the model number, e.g., MSA-S24-1NB. Usable Stand Height Pole 40 mm (1.58") Square (4) M10 Bolt 120.6 mm (4.75") Base 6.4 mm (0.25") www.bannerengineering.com - Tel: 763.544.3164 17 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 3.5 Replacement Parts Description Model Access cover with label - receiver EA5-ADR-1 Access cover security plate (includes 2 screws, wrench) EZA-TP-1 Wrench, security EZA-HK-1 Standard bracket kit with hardware (includes 2 end brackets and hardware to mount to MSA Series stands) Black EZA-MBK-11 Stainless Steel EZA-MBK-11N Center bracket kit (includes 1 bracket and hardware to mount to MSA Series stands) EZA-MBK-12 3.6 Specifications Emitter/Receiver Range 400 mm to 4 m (16" to 13') Beam Spacing 5 mm (0.2 in) Field of View Nominally ±3° Light Source Infrared LED Minimum Object Detection Size Straight Scan, Low-Contrast: 5 mm (0.2 in) Straight Scan, High-Excess-Gain: 10 mm (0.4 in) See Scanning Method for other scan mode values; size is tested using a rod. System Configuration (Receiver Interface) 6-position DIP switch: Used to set scanning type, measurement modes, analog slope, and discrete output 2 function (see Configuration DIP Switch) Push Buttons: Two momentary push buttons for alignment and gain level selection Supply Power Requirements Emitter/Receiver Pair (Exclusive of Discrete Load): Less than 9 watts Power-up delay: 2 seconds IO-Link Interface Baud Rate: 38,400 bps (COM2) Process Data Width: 16 bits System Configuration (IO-Link Interface) Supplied IODD files provide all configuration options of receiver interface, plus additional functionality; see Overview and IO Link Device Description Supply Voltage (Limit Values) Emitter: 12 to 30 V dc Receiver Models: 18 to 30 V dc Teach Input (Receiver Gray Wire) Low: 0 to 2 volts High: 6 to 30 volts or open (input impedance 22 K ohms) Sensor Positional Resolution Straight Scan: 5 mm (0.2 in) Double-Edge Scan: 2.5 mm (0.1 in) Single-Edge Scan: 2.5 mm (0.1 in) Two Discrete Outputs Protected against false pulse on power-up and continuous overload or short circuit. Discrete Output 1 (SIO Mode) Two Analog Outputs Voltage Sourcing: 0 to 10V (maximum current load of 5 mA) Scan Time Scan times depend on scan mode and sensor length. Straight scan times range from 2.8 to 26.5 ms. See Maximum Scan Time for all combinations. Connections IO-Link Interface: The receiver uses a cable splitter that converts the 8-pin connector to a compatible M12 IO-Link connector; see Cordsets and Connections. Other Sensor connections: 8-conductor quick-disconnect cables (one each for emitter and receiver), ordered separately; see Cordsets and Connections for available lengths (may not exceed 75 meters long), PVC-jacketed cables measure 5.8 mm diameter, have shield wire; 22-gauge conductors Type: Solid-State Push-Pull Rating: 100 mA maximum (sourcing or sinking) ON-State Saturation Voltage: less than 3 V @ 100 mA (sourcing or sinking) Discrete Output 2 Type: Solid-State NPN or PNP (current sinking or sourcing) Rating: 100 mA maximum OFF-State Leakage Current: NPN: less than 200 µA @ 30 V dc; PNP: less than 10 µA @ 30 V dc ON-State Saturation Voltage: NPN: less than 1.6 V @ 100 mA; PNP: less than 2.0 V @ 100 mA Environmental Rating IEC IP65 Operating Conditions −40 °C to +70 °C (−40 °F to +158 °F) 95% at +50 °C maximum relative humidity (non-condensing) Certifications Construction Aluminum housing with clear-anodized finish; acrylic lens cover 18 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 3.7 Emitter and Receiver Dimensions 45.2 mm (1.78") 36.0 mm (1.42") 12 mm (0.47") Y L1 L2 L3 56.0 mm (2.20") 59 mm (2.3") 65 mm (2.6") 4.2 mm (0.17") R13 mm (0.5") minimum bend IO-Link Splitter With Cable Splitter Connection With Cable Connection Emitter or Receiver Model Housing Length L1 Distance Between Bracket Holes L2 L3 Defined Area Y EA5..150.. 227 mm (8.9 in) 260 mm (10.2 in) 199 mm (7.8 in) 150 mm (5.9 in) EA5..300.. 379 mm (14.9 in) 412 mm (16.2 in) 351 mm (13.8 in) 300 mm (11.8 in) EA5..450.. 529 mm (20.8 in) 562 mm (22.1 in) 501 mm (19.7 in) 450 mm (17.7 in) EA5..600.. 678 mm (26.7 in) 704 mm (27.7 in) 650 mm (25.6 in) 600 mm (23.6 in) EA5..750.. 828 mm (32.6 in) 861 mm (33.9 in) 800 mm (31.5 in) 750 mm (29.5 in) EA5..900.. 978 mm (38.5 in) 1011 mm (39.8 in) 950 mm (37.4 in) 900 mm (35.4 in) EA5..1050.. 1128 mm (44.4 in) 1161 mm (45.7 in) 1100 mm (43.3 in) 1050 mm (41.3 in) EA5..1200.. 1278 mm (50.3 in) 1311 mm (51.6 in) 1250 mm (49.2 in) 1200 mm (47.2 in) EA5..1500.. 1578 mm (62.1 in) 1611 mm (63.4 in) 1550 mm (61.0 in) 1500 mm (59.1 in) EA5..1800.. 1878 mm (73.9 in) 1911 mm (75.2 in) 1850 mm (72.8 in) 1800 mm (70.9 in) EA5..2100.. 2178 mm (85.7 in) 2211 mm (87.0 in) 2150 mm (84.6 in) 2100 mm (82.7 in) EA5..2400.. 2478 mm (97.6 in) 2511 mm (98.9 in) 2450 mm (96.4 in) 2400 mm (94.5 in) www.bannerengineering.com - Tel: 763.544.3164 19 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 3.8 Standard Bracket Dimensions Center Bracket (model EZA-MBK-12**) End Cap Brackets (model EZA-MBK-11*) 4 x 5.8 mm (0.23") wide slots Ø 21.5 mm (0.85") Ø 33 mm (1.30") 4 x R 19.4 mm (0.76") 4 x 45 38.2 mm (1.50") 20 mm (0.79") 55 mm (2.17") 4.2 mm (0.17") 63.2 mm (2.49") Ø 60 mm 20 mm (0.79") 20 mm (0.79") 55.6 mm (2.19") 25 mm (0.98") 50 mm (1.96") 4.2 mm (0.17") 9.5 mm (0.37") 2 x 5 mm (0.20") 2 x 15 mm (0.59") 2 x 7 mm (0.28") 2 x R 5 mm (0.20") 17.5 mm (0.69") 50 mm (1.97") 10 mm (0.39") Ø 8.3 mm (0.33") 36 mm (1.42") Ø 7 mm (0.28") 15 mm (0.59") 20.0 mm (0.79") 20 mm (0.79") *Dimensions are identical for model EZA-MBK-11N stainless steel brackets. ** Supplied with emitters and receivers over 1050 mm. 20 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 4 Installation and Alignment 4.1 Mounting the Emitter and Receiver Compact EZ-ARRAY emitters and receivers are easy to handle during mounting. When mounted to the sensor end caps, the supplied mounting brackets allow ±30° rotation. An emitter may be separated from 400 mm to 4 m (16 in to 13 ft) from its receiver. From a common point of reference, make measurements to locate the emitter and receiver in the same plane, with their midpoints and display ends directly opposite each other. (If sensors are mounted with their display ends at the top, see Receiver Gray Wire or refer to HW Interface table in General Configuration for directions on inverting the 3-digit display.) Mount the brackets to the emitter and receiver housings using the supplied M6 bolts and Keps nuts, or user-supplied hardware. Center mounting brackets must be used with longer sensors, if they are subject to shock or vibration. In such situations, the sensors are designed to be mounted with up to 900 mm unsupported distance (between brackets). Sensors 1050 mm and longer are supplied with a center bracket to be used as needed with the standard end-cap brackets. 1. Attach the center bracket to the mounting surface when mounting the end-cap brackets. 2. Attach the clamp to both slots of the housing, using the included M5 screws and T-nuts. 3. After the sensor is mounted to the end-cap brackets, attach the clamp to the center bracket using the supplied M5 screw. EZ-ARRAY End-Cap Brackets (supplied with each emitter and receiver) End-Mounted Side-Mounted (two sensor brackets may be substituted) Swivel Center Bracket (supplied with emitters and receivers 1050 mm and longer) Sensors are designed to be mounted with up to 900 mm unsupported distance between brackets. 4.2 Mechanical Alignment Mount the emitter and receiver in their brackets and position the windows of the two units directly facing each other. Measure from one or more reference planes (e.g., the building floor) to the same point(s) on the emitter and receiver to verify their mechanical alignment. Use a carpenter's level, a plumb bob, or the optional LAT-1-SS Laser Alignment Tool, or check the diagonal distances between the sensors, to achieve mechanical alignment. When alignment is difficult, a LAT-1-SS tool is useful to assist or confirm alignment by providing a visible red dot along the sensor's optical axis. Snap the LAT-1 clip onto the sensor housing, turn on its laser emitter, and use a strip of retroreflective tape at the opposite sensor to see the dot. Also check "by eye" for line-of-sight alignment. Make any necessary final mechanical adjustments, and hand-tighten the bracket hardware. See Optical Alignment and Alignment Blanking Button for further alignment information. www.bannerengineering.com - Tel: 763.544.3164 21 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Verify that: • The emitter and receiver are directly opposite each other, and nothing is interrupting the beams. • The sensing area is the same distance from a common reference plane for each sensor. • The emitter and receiver are in the same plane and are level/ plumb and square to each other (vertical, horizontal, or inclined at the same angle, and not tilted front-to-back or side-to-side). Emitter Receiver A level level B level X level X Y Z Y Z Level Surface X X Level Surface Angled or Horizontal Installations - verify that: • Distance X at the emitter and receiver are equal. • Distance Y at the emitter and receiver are equal. Vertical Installations - verify that: • Distance Z at the emitter and reciever are equal from parallel • Distance X at emitter and receiver are equal. surfaces. • Both sensors are level/plumb (check both the side and • Vertical face (i.e., the lens) is level/plumb. face). • Sensing area is square. Check diagonal measurements if • Sensing area is square. Verify diagonal measurements possible; see Vertical Installations at right. if possible (Diagonal A = Diagonal B). 4.3 Wiring Diagrams Inputs Receiver gray wire: The receiver has an input that can be used as a gate input or for remote teach. To initiate remote teach, alignment, and gating functions, tie the wire through a switch to sensor common. See Receiver Gray (Remote Teach) Wire for more information. PNP Outputs without IO-Link Master www.bannerengineering.com - Tel: 763.544.3164 + Emitter bn bn Power Supply V- bu bu Power Supply V- Sync pk pk Sync V Out 1 wh V Out 2 ye Out 1 gn Out 2 rd Teach gy Shield bare + 22 – Power Supply V+ Power Supply V+ wh + Discrete Outputs: The receiver has two discrete outputs; the green wire is referenced as discrete output 1, and the red wire is referenced as discrete output 2. Discrete output 1 is a push-pull output. Discrete output 2 is PNP, unless the polarity is altered via the communication interface. Refer to Specifications for further electrical requirements. 18-30V dc Power Receiver – Analog white and yellow wires: The receiver has two analog outputs. Both outputs are voltage analog outputs. The white wire is referenced as analog output 1; the yellow wire is referenced as analog output 2. The voltage analog outputs will source current through an external load to sensor common. – Outputs ye gn rd Load gy Load 0-2V dc bare Shield A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Wiring with an IO-Link Master Receiver bn Power Supply V+ bn Power Supply V- bu Sync pk IO-Link Cable Splitter bu pk Emitter Power Supply V+ Power Supply VSync 2 7 6 2 7 6 3 8 1 3 4 2 rd* * Out 2 can be either Discrete Output 2 or Voltage Output 1, depending on splitter model Ou Out 2* t2 * C/ Q VV+ gn C/Q IO-Link Master Sync (Pink) Wire: The emitter and receiver are electrically synchronized via the pink wire. The emitter and receiver pink wires must only be electrically connected together. 4.4 Optical Alignment After the electrical connections are made, power up the emitter and receiver. Verify that input power is present to both emitter and receiver; the emitter Status indicator and the receiver Status LED should be ON green. If the receiver Status LED is on red (and a "c" appears on the 3-digit display), refer to Troubleshooting and Error Codes. Note: At power-up, all Zone indicators are tested (flash red), then the number of blocked beams is displayed. a) Straightedge Straightedge 0 beams blocked; all Zone indicators ON Green Observe the receiver indicators (see table below). Optimize Alignment and Maximize Excess Gain Verify that the emitter and receiver are pointed squarely at each other. A straightedge (e.g., a level) can help determine the direction the sensor is facing. Slightly loosen the sensor mounting screws and rotate one sensor to the left and right, noting the positions where the receiver Zone indicators turn from green to red; repeat with the other sensor. Center each sensor between the noted positions and tighten the end cap mounting screws, making sure to maintain the positioning. The sensor windows should directly face each other. Once optimum optical alignment is verified, proceed to configuration, via the remote teach wire, the receiver interface, or the IO-Link interface (Receiver Gray Wire, Alignment Blanking Button, or refer to the Appendix: IO Link Alignment Blanking Routine) and complete the electronic alignment. This further alignment step adjusts the emitted light level of each beam for the application, to maximize sensing performance. b) 60 beams blocked; all Zone indicators ON Red c) 30 beams blocked; 4 Zone indicators ON Green, 3 ON Red d) 0 beams blocked; all Zone indicators ON Green Optimizing optical alignment; 300 mm model shown www.bannerengineering.com - Tel: 763.544.3164 23 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Receiver Interface Indicators during Alignment All Beams Either Clear or Blanked Some Beams Blocked or Mis-Aligned Out of Alignment Zone Indicators All ON Green Some ON Red (zones with blocked beams) Some ON Green (zones with all clear beams) All ON Red (Some beams blocked in each zone) Receiver Status Indicator ON Green ON Green ON Green 3-Digit Display 0 (Number of blocked beams) Number of blocked beams Total number of beams in the array 24 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 5 Receiver User Interface The receiver user interface comprises the six-position DIP switch, two push buttons, 3-digit display, and other indicators present on the receiver (see Status Indicators for more complete status indicator information). The receiver interface enables configuration of standardized combinations of the EZ-ARRAY sensing options (output configuration, scanning methods and modes); for more advanced setup, refer to to IO-Link Interface. 5.1 Configuration DIP Switches Use the DIP switches to configure the sensor. Access the switch by removing the screw-on security plate and lifting the clear hinged access cover. The access cover may be removed entirely (pull straight out to remove, press back in to replace) for easier access during configuration. Some of the switches are assigned their own functions, others work together in combination (see table). To open access cover, insert a small flat-blade screwdriver, press up, and pull. Switches S1 and S2 in combination select one of four scanning modes. Switches S3 and S4 in combination select one of four measurement mode pairs (one for each analog output). Switch S5 defines the analog slope setting for both analog outputs and S6 defines whether discrete output 2 is complementary to discrete 1 or functions as an alarm (when configuration is accomplished via DIP switch, discrete output 1 and analog output 1 follow the same measurement mode). All DIP switch positions are shown in the ON (default) position. Receiver User Interface DIP Switches Description S1 S2 S3 S4 Scan Mode: Straight Scan ON* ON* Scan Mode: Double-Edge, Step 1 ON OFF Scan Mode: Double-Edge, Step 4 OFF ON Scan Mode: Single-Edge OFF OFF Analog 1 TBB; Analog 2 FBB ON* ON* Analog 1 LBB; Analog 2 MBB ON OFF Analog 1 OD; Analog 2 ID OFF ON Analog 1 CBB; Analog 2 CFBB OFF OFF S5 Positive Analog Slope ON* Negative Analog Slope OFF S6 Discrete 2 Complementary ON* DIscrete 2 Alarm OFF * Factory default settings 5.1.1 Scanning Modes (S1 and S2) See Maximum Scan Times on page 11for scan times. Double-Edge Step 1 (S1 ON, S2 OFF) Double-Edge Step 1 can be used when three or fewer opaque objects are presented to the light curtain at one time. The advantage of this mode is improved sensor edge resolution (2.5 mm). The minimum object detection size is 10 mm. Double-Edge Step 4 (S1 OFF, S2 ON) Double-Edge Step 4 can be used when three or fewer opaque objects are presented to the light curtain and the minimum size object to be detected is 30 mm. This scanning mode ignores objects smaller than 30 mm. Like Double-Edge Step 1, the sensor edge resolution is 2.5 mm. www.bannerengineering.com - Tel: 763.544.3164 25 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Single-Edge Scan (S1 OFF, S2 OFF) Single-Edge Scan can be used when a single opaque object is presented to the light curtain at one time. The object must block the "bottom" channel (the channel closest to the receiver display). Like the double-edge scans, the sensor edge resolution is 2.5 mm. The minimum object detection size is 10 mm. Because single-edge scan is capable only of measuring the height of an opaque object that blocks the bottom channel and all channels up to the height of the object, the pertinent measurement modes are LBB (last beam blocked) or TBB (total beams blocked). When single-edge scan is selected, the selected measurement mode will be applied to both analog outputs. Selection of OD/ID with single-edge scan will result in an error code. Straight Scan (S1 ON, S2 ON) Straight Scan is the most versatile scanning mode and can be used without the exceptions noted in the other scanning modes. Use this scanning mode when using the low-contrast sensitivity setting to measure semi-transparent materials. 5.1.2 Measurement Modes (S3 and S4) The measurement modes, determined by switches S3 and S4 in combination, define what information is calculated by the sensor and sent via the analog outputs. See Measurement Mode Selection for measurement mode definitions. Discrete output 1 and analog output 1 will follow the same measurement mode. (If single-edge scan is selected, select measurement mode LBB or TBB.) During normal operation, the 3-digit diagnostic display reads out the numerical value of the specified measuring mode for analog output 1. 5.1.3 Analog Slope (S5) Switch S5 defines the analog output slope. As the measurement mode values increase, the analog output voltage can either increase (positive slope, S5 ON) or decrease (negative slope, S5 OFF). Switch S5 applies the same slope to both analog outputs. 5.1.4 Complementary/Alarm (S6) Switch S6 defines the operation of discrete output 2. When the receiver user interface is used, discrete output 1 is active when an object is detected by the sensor (normally open operation). In complementary mode (S6 ON), output 2 will always be in the opposite state of output 1. In alarm mode (S6 OFF), discrete output 2 will be active when the sensor detects a system fault. System faults include a failed emitter, mis-wiring of the emitter/receiver communication wire (the pink wire), and low excess gain (if the sensor is configured for high-contrast sensitivity). 5.2 Alignment/Blanking Button (Electronic Alignment) The Alignment/Blanking push button is used both to maximize the alignment and to access the blanking feature. The electronic alignment routine adjusts the emitted light level to maximize sensor performance. Perform the procedure at installation and again when the emitter and/or receiver is moved. For IO-Link interface alignment instructions, see Alignment Blanking Routine. Blanking is used to maintain sensing accuracy in applications where a fixed object (for instance a permanently mounted bracket) will block one or more beams. The sensor will ignore the blanked channels when calculating outputs from the selected measurement modes. 5.2.1 Electronic Alignment and Blanking - Receiver Interface To initiate the electronic alignment procedure, use a small screwdriver to press the Alignment/Blanking button for two or more seconds. The left-hand digit of the 3-digit display will read "A" (representing alignment); the right two digits will show the number of beams blocked. The receiver is learning the clear condition. Rotate the sensors as required (but do not change the distance between them). When the receiver's 3-digit display shows 0 beams blocked, the sensors are adequately aligned. Tighten the sensor mounts, then press the Alignment/Blanking button again for two seconds to exit alignment mode. If all sensor light channels are clear, the EZ-ARRAY stores each channel's signal strength in non-volatile memory and reads "- - -" on the 3-digit display. Re-alignment is not required again, unless the emitter or receiver is moved. If any beams are blocked by objects other than the sensing target to be measured during run mode, those beams can be blanked in alignment mode for more accurate measurement. The blocked beams must be either blanked or cleared during alignment mode for alignment to proceed (see below). While the "A" is visible on the receiver display, momentarily (about 0.5 seconds max.) press the Alignment/Blanking button again. The "A" will change to "n" to indicate the sensor is ready to "learn" the blanking pattern; momentarily press the button again to exit the blanking routine. The sensor blanks the blocked beams and the display changes to "A."; the period following the lefthand digit signifies blanking is active. Press the Alignment/Blanking button for two seconds to exit alignment mode. The EZ-ARRAY stores each channel's signal strength in non-volatile memory and reads "-. - -" on the 3-digit display to denote blanking is in use. 26 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 5.2.2 Flashing "000" on the 3-Digit Display When returning to run mode, the receiver determines whether any unblanked beam channels are obstructed. If any channels are obstructed, the new alignment settings are not saved; the receiver flashes zeroes on the display three times and sensing will continue, using the previously set alignment settings. If this occurs, either clear the blocked beams and repeat the alignment routine or repeat the alignment routine and blank the blocked beams. 5.3 Gain (Sensitivity Adjust) Button To change the sensitivity (Gain setting), press and hold the button for two seconds. The left-hand digit of the 3-digit display will read " L "; the right-hand digit will read "1" (high excess-gain) or "2" (low-contrast). The sensitivity level can then be toggled between the values 1 and 2. When the desired sensitivity level is displayed, hold the Gain push button for 2 seconds and the sensor will return to run mode. 5.4 Inverting the 3-Digit Display For instances where the sensors must be mounted in an inverted position, the 3-digit display can be can be inverted for readability. See Receiver Gray Wire. The 3-digit display can then be switched back to "normal" by repeating the procedure. Note: The periods on the three seven-segment indicators do not move when the display is inverted. 5.5 Troubleshooting and Error Codes If the receiver Status LED is red and the 3-digit display reads "c" followed by a number from 1 to 10, a corrective action is needed (see table below). 5.5.1 "Dirty" Channel Indicator If the Status LED is red, but no "c" is visible on the 3-digit display (the scan measurement mode result is displayed), the sensor alignment is marginal. Clean the sensor windows and perform the alignment procedure as necessary. For all corrective actions, first verify proper supply voltages and wiring connectivity. Disconnect and re-connect the sensor cable connectors to verify proper connector installation. Error Code Problem Corrective Action 1 Receiver EEPROM Hard Failure This problem is caused by a receiver failure that cannot be corrected by the user. Replace the receiver. 2 Receiver Alignment/Blanking Configuration Error Remove and re-apply sensor supply voltage. If the error code 2 is removed, electrically re-align the sensor (Alignment/Blanking Button). If the error code persists, contact Banner for further problem-solving techniques. 3 Reserved for Factory Replace the receiver. 4 Emitter or Wiring Problem 1. 2. 3. Verify that emitter and receiver wiring is correct (see Wiring Diagrams on page 22). Check the status of the emitter Status LED. Emitter LED OFF: Check the voltage across the emitter brown and blue wires. If the voltage across the emitter brown and blue wire is OK, then replace the emitter. Emitter Status LED flashing (approx. every 2 seconds): Verify that the emitter/receiver synch (pink) wires are correctly installed. Verify that the Synch wires are correctly installed. Check the synch wire dc voltage. If the voltage is below 1 volt or above 3 volts, then again check the synch wire for possible mis-wiring. Unplug first the receiver and then the emitter to determine the problem source. 5 Emitter Channel Error The emitter has identified a nonfunctional optical channel. Temporary fix: Blank the channel (Section Alignment/Blanking Button) to ignore the problem. Permanent fix: Replace the emitter. 6 Reserved for Factory Replace the receiver. 7 Reserved for Factory Replace the emitter. 8 Reserved for Factory Replace the receiver. 9 Reserved for Factory Replace the receiver. 10 Incompatible Scan and Measurement Mode Some measurement modes are incompatible with some scanning modes. Single-Edge Scan; do not use the following measurement modes: OD, ID, FBM, LBM, TBM, CBM, Nap Detection Double-Edge Scan; do not use the following measurement modes: FBM, LBM, TBM, CBM, Nap Detection www.bannerengineering.com - Tel: 763.544.3164 27 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 6 IO-Link Interface 6.1 Overview For the latest IO-Link protocol and specifications, please visit the web site at http://www.io-link.com IO-Link is a point-to-point communication link between master and slave. It can be used to automatically parameterize sensors and transmit process data. 6.2 IO-Link Profile and Models IO-Link Version 1.0 COM-Mode COM2 (38,400 bps) Process Data Width 16-Bit Process Data Structure Input Data: Bit 0-12: Measurement 1 Value, Bit 13-15: Reserved SIO-Mode Support Yes Memory Request for Data Management 180 Bytes Sub-Index Access Not Supported Model Device ID Min. Cycle Time (ms) EA5R150XKQ 65536 11.6 EA5R300XKQ 65537 19.2 EA5R450XKQ 65538 26.4 EA5R600XKQ 65539 35.2 EA5R750XKQ 65540 43.2 EA5R900XKQ 65541 49.6 EA5R1050XKQ 65542 57.6 EA5R1200XKQ 65543 64.0 EA5R1500XKQ 65545 80.0 EA5R1800XKQ 65546 94.4 EA5R2100XKQ 65547 108.8 EA5R2400XKQ 65548 123.2 6.3 Hardware Interface IO-Link is designed around IEC 61131-9 Single-drop digital communication interface for sensors and actuators (SDCI). The figure below shows the SDCI connection for 3-wire connection devices. Power, ground, communication, and/or switching signal are required, pin 2 is an optional I/O. The EZ-ARRAY provides the SDCI connection with an IO-Link cable splitter accessory. The EZ-Array is a Port Class A device. 28 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 6.3.1 Electrical Interface IO-Link Splitter Connector #1 CSB-M1240M1280 (Dual Discrete) Pinouts EZ-ARRAY 8-Pin Connector 8-Wire Cable Signal Definition EZ-ARRAY 8-Pin Connector 8-Wire Cable Signal Definition 1 2 Brown L+ 18-30 VDC 2 Brown L+ 18-30 VDC 2 8 Red Q Switching Signal D02 1 White AO V Out 1 (0-10V) 3 7 Blue L- 0 VDC 7 Blue L- 0 VDC 4 3 Green Q Switching Signal DO1 (SIO) 3 Green Q Switching Signal DO1 (SIO) C IO-Link (SDCI) C IO-Link (SDCI) N.C. No Connection N.C. No Connection 5 N.C. N.C. IO-Link Splitter CSB-M1250M1280 (Analog) Pinouts N.C. N.C. CSB-M1240M1280 is shown, for CSB-M1250M1280 pin 1 is connected 2 7 6 3 8* 2 7 6 1 3 4 2 Note: If an additional cable between the receiver and splitter is required, its length must be less than a meter. 6.3.2 IO-Link Master A list of IO-Link Master manufacturers can be found under the About Us at www.io-link.com. 6.4 IODD (IO-Link Device Description) An IODD file is a file that formally describes a device using XML notation. The IODD provides all the necessary properties to establish communication and configuration. The EZ-ARRAY IO-Link IODD package consists of an IODD file, and three image files: • Banner_Engineering---IODD1.0.1.xml • Banner_Engineering-logo.png • Banner_Engineering-EA5RXK-icon.png • Banner_Engineering-EA5RXK-pic.png This IO-Link IODD package is contained on the supplied IO-Link Device Description Resource CD (P/N 18491). For the latest IODD packages, please refer to the Banner website at http://www.bannerengineering.com/IO-Link. 6.5 Configuration Data IO-Link models of the EZ-ARRAY use the Service Parameter Data Unit (SPDU) channel for providing read-write access to configuration data. 6.5.1 Scan Configuration The Scan Configuration contains the settings for the scan type and receiver's remote teach wire (gray wire) function. www.bannerengineering.com - Tel: 763.544.3164 29 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual SPDU Byte Position Member Name Index Sub-Index 80 1 0 Scan Type 80 2 1 Remote Teach/Gate Scan Type Value Type Description 1 Straight Straight Scanning 2 Single Edge Scanning for Single Edge 3 Double Edge - Step 1 Scanning for Edges of up to 3 objects (fires every channel) 4 Double Edge - Step 2 Scanning for Edges of up to 3 objects (fires channels 1, 3, 5, ...) 5 Double Edge - Step 4 Scanning for Edges of up to 3 objects (fires channels 1, 5, 9, ...) 6 Double Edge - Step 8 Scanning for Edges of up to 3 objects (fires channels 1, 9, 17, ...) 7 Double Edge - Step 16 Scanning for Edges of up to 3 objects (fires channels 1, 17, 33, ...) 8 Double Edge - Step 32 Scanning for Edges of up to 3 objects (fires channels 1, 33, 65, ...) 10 Carpet Nap Scanning for Carpet Nap Detection Applications Remote Teach/Gate Value Function Description 0 Disabled Disabled 1 Remote Teach Enabled with All Functionality 2 Alignment/Sensitivity Only Alignment, Blanking, and Sensitivity Adjustments can be performed 3 Gate - Active High Setting the gray wire in the high state enables scanning 4 Gate - Active Low Setting the gray wire in the low state enables scanning 5 Gate - Rising Edge A single scan will occur after the gray wire goes from a low-to-high state 6 Gate - Falling Edge A single scan will occur after the gray wire goes from a high-to-low state 6.5.2 Blanking Configuration The Blanking Configuration contains the blanking bit-mask for the EZ-ARRAY's channels. Each sub-index represents 16 channels. Blanking Configuration SPDU Byte Position Member Name Index Sub-Index 81 1 0 Blanking 1-8 81 1 1 Blanking 9-16 81 ... ... ... 81 30 58 Blanking 465-472 81 30 59 Blanking 473-480 Blanking Bit-Mask Value 0 30 Status Description Non-Blanked The channel will be used during scanning www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Blanking Bit-Mask Value 1 Status Description Blanked The channel will be skipped during scanning 6.5.3 General Configuration The General Configuration contains the general settings for the EZ-ARRAY. SPDU Byte Position Member Name Index Sub-Index 86 1 0 Emitter Power 86 2 1 Gain Method 86 3 2 Low Contrast Sensitivity 86 See table A-11 3 HW Interface Flags 86 9 4 Measurement 1 (Input Process Data) 86 10 5 86 12 8-9 86 13 10-13 Measurement 2 Number of Dirty Channels Time of Service Emitter Power Value Function Description 1 Level 1 Power Setting 1 (Lowest) 2 Level 2 Power Setting 2 3 Level 3 Power Setting 3 4 Level 4 Power Setting 4 5 Level 5 Power Setting 5 6 Level 6 Power Setting 6 7 Level 7 Power Setting 7 8 Level 8 Power Setting 8 9 Level 9 Power Setting 9 10 Level 10 Power Setting 10 11 Level 11 Power Setting 11 (Highest) Gain Method Value Status Description 1 High-Excess Gain Fixed thresholds for maximum excess gain 2 Low Contrast Adjustable percentage based thresholds (only in Straight Scan) Low Contrast Sensitivity Value Function Description 0 10% Blocked threshold is set 10% below aligned signal 1 15% Blocked threshold is set 15% below aligned signal 2 20% Blocked threshold is set 20% below aligned signal www.bannerengineering.com - Tel: 763.544.3164 31 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Low Contrast Sensitivity Value Function Description 3 25% Blocked threshold is set 25% below aligned signal 4 30% Blocked threshold is set 30% below aligned signal 5 35% Blocked threshold is set 35% below aligned signal 6 40% Blocked threshold is set 40% below aligned signal 7 45% Blocked threshold is set 45% below aligned signal 8 50% Blocked threshold is set 50% below aligned signal HW Interface Flags SPDU Sub-Index Bit Position Flag Description 4 0 Display Orientation 0 = Normal, 1 = Inverted 5 1 Configuration Type 0 = DIP Switch, 1 = Advanced Control 6 2 Sensitivity Button 0 = Enabled, 1 = Disabled 7 3 Align/Blank Button 0 = Enabled, 1 = Disabled Measurement 1 & Measurement 2 32 Value Function Description 0 Disabled Disabled 1 FBB First Beam Blocked 2 LBB Last Beam Blocked 3 TBB Total Beams Blocked 4 TRN Transitions 5 CBB Contiguous Beams Blocked 6 FBM First Beam Made 7 LBM Last Beam Made 8 TBM Total Beams Made 9 CBM Contiguous Beams Made 10 MBB Middle Beam Blocked 11 OD Outer Diameter 12 ID Inner Diameter 13 CFBB Contiguous First Beam Blocked 14 CLBB Contiguous Last Beam Blocked 15 O1 FBB Object 1 First Beam Blocked 16 O1 LBB Object 1 Last Beam Blocked 17 O2 FBB Object 2 First Beam Blocked 18 O2 LBB Object 2 Last Beam Blocked 19 O3 FBB Object 3 First Beam Blocked 20 O3 LBB Object 3 Last Beam Blocked 21 CARPET NAP Carpet Nap 24 CARPET EDGE Carpet Edge www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Number of Dirty Channels Range Description 1-360 Number of channels that need to be dirty before indicator is lit (150 to 1800 mm Length Models) 1-480 Number of channels that need to be dirty before indicator is lit (2100 to 2400 mm Length Models) Time of Service Range Description 232 – 1 Number of hours EZ-ARRAY has been in operation 6.5.4 Analog Output 1 Configuration The Analog Output 1 Configuration contains the settings for the first analog output. SPDU Byte Position Member Name Index Sub-Index 82 See table A-22 0 Config Flags 82 9 2 Filter Speed 82 11 4-5 NULL Output 82 12 6-7 SPAN Output Config Flags (Analog Output 1 & 2) SPDU Sub-Index Bit Position Flag Description 1 0 Slope 0 = Negative, 1 = Positive 2 1 Measurement 0 = Measurement 2, 1 = Measurement 1 3 2-3 4 4 ZERO Value 0 = Hold, 1 = Minimum, 2 = Maximum Peak Detect 0 = Disabled, 1 = Enabled 5 5 Peak Detect Direction 0 = Maximum, 1 = Minimum 6 6 Status 0 = Disabled, 1 = Enabled 7 7 Peak Detect Reset 0 = Auto, 1 = External Communications Filter Speed (Analog Output 1 & 2) Value Filter Speed Description 0 Fast No filtering 1 Medium Filter step response is 6 scans for 98% of signal 3 Slow Filter step response is 24 scans for 98% of signal NULL Output (Analog Output 1 & 2) Range Description 0-4095 Minimum DAC value of Analog Output (MUST be < SPAN Output) www.bannerengineering.com - Tel: 763.544.3164 33 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual SPAN Output (Analog Output 1 & 2) Range Description 0-4095 Maximum DAC value of Analog Output (MUST be > NULL Output) 6.5.5 Analog Output 2 Configuration The Analog Output 2 Configuration contains the settings for the second analog output. SPDU Byte Position Member Name Index Sub-Index 83 See Table A-22 0 Config Flags 83 9 2 Filter Speed 83 11 4-5 NULL Output 83 12 6-7 SPAN Output 6.5.6 Discrete Output 1 Configuration The Discrete Output 1 Configuration contains the settings for the first discrete output. SPDU Byte Position Member Name Index Sub-Index 84 See Table A-28 0 Config Flags 84 7 2-3 Scan Response 84 8 4-5 Hysteresis LOW 84 9 6-7 Hysteresis HIGH 84 10 8-9 Threshold LOW 84 11 10-11 Threshold HIGH Config Flags (Discrete Output 1 & 2) SPDU Sub-Index Bit Position Flag Description 1 0 Status 0 = Disabled, 1 = Enabled 2 1 Type 0 = Measurement, 1 = Alarm/Health (Discrete Output 1 can ONLY be of type Measurement) 3 2 Polarity5 0 = PNP, 1 = NPN 4 3 Mode6 0 = Normally Closed (Health), 1 = Normally Open (Alarm) 5 4 Measurement 0 = Measurement 2, 1 = Measurement 1 Scan Response (Discrete Output 1 & 2) Range Description 1-250 Number of consecutive measurements before changing state Hysteresis LOW (Discrete Output 1 & 2) Range Description 0-359 Lower hysteresis threshold for discrete output (MUST be < Threshold LOW) (150 to 1800 mm Length Models) 5 IO-Link Model: Discrete Output 2 ONLY, Discrete Output 1 is PUSH-PULL 6 For Type = Alarm/Health, Mode setting corresponds to 0=Health, 1=Alarm 34 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Hysteresis LOW (Discrete Output 1 & 2) Range Description 0-479 Lower hysteresis threshold for discrete output (MUST be < Threshold LOW) (2100 to 2400 mm Length Models) Hysteresis HIGH (Discrete Output 1 & 2) Range Description 2-361 Upper hysteresis threshold for discrete output (MUST be > Threshold HIGH) (150 to 1800 mm Length Models) 2-481 Upper hysteresis threshold for discrete output (MUST be > Threshold HIGH) (2100 to 2400 mm Length Models) Threshold LOW (Discrete Output 1 & 2) Range Description 1-360 Lower threshold for discrete output (MUST be = Threshold LOW) (2100 to 2400 mm Length Models) 6.5.7 Discrete Output 2 Configuration The Discrete Output 2 Configuration contains the settings for the second discrete output. SPDU Byte Position Member Name Index Sub-Index 85 See Table A-28 0 Configuration 85 7 2-3 Demodulation Count 85 8 4-5 Hysteresis LOW 85 9 6-7 Hysteresis HIGH 85 10 8-9 Threshold LOW 85 11 10-11 Threshold HIGH 6.6 System Status and Measurement Data IO-Link models of the EZ-ARRAY use the SPDU channel to provide access to system status measurement data and the Alignment/ Blanking routine. 6.6.1 Active Measurements The Active Measurements section contains the current values of the two measurements that were configured in the General Configuration. SPDU Byte Position Member Name Index Sub-Index 64 1 0-1 Measurement 1 64 2 2-3 Measurement 2 www.bannerengineering.com - Tel: 763.544.3164 35 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Measurement 1 and Measurement 2 Range Description 0-1920 Measurements are represented in 4x channel resolution 6.6.2 ALL Measurements The ALL Measurements section contains the current values of all the available measurements. SPDU Byte Position Member Name FBB Index Sub-Index 67 1 0-1 67 2 2-3 LBB 67 3 4-5 TBB 67 4 6-7 TRN 67 5 8-9 CBB 67 6 10-11 FBM 67 7 12-13 LBM 67 8 14-15 TBM 67 9 16-17 CBM 67 10 18-19 MBB 67 11 20-21 OD 67 12 22-23 ID 67 13 24-25 CFBB 67 14 26-27 CLBB 67 15 28-29 O1 FBB 67 16 30-31 O1 LBB 67 17 32-33 O2 FBB 67 18 34-35 O2 LBB 67 19 36-37 O3 FBB 67 20 38-39 O3 LBB 67 21 40-41 CARPET NAP 67 22 42-43 AO1 PEAK 67 23 44-45 AO2 PEAK 67 24 46-47 CARPET EDGE Measurements (ALL) Range Description 0-1920 Measurements are represented in 4x channel resolution AO1 PEAK and AO2 PEAK Measurements The AO1 PEAK and AO2 PEAK measurements store the minimum/maximum values of Analog Output 1 and Analog Output 2 respectively. When the EZ-ARRAY's Analog Outputs are configured to have Peak Detect = Enabled and Peak Detect Reset = External Communications, then reading these measurements will reset the Analog Output Peak Detect value. To enable this mode of operation, the Analog Output's Configuration Flags must be configured as shown in Example 1 (see Table A-22). Example 1. Analog Output Configuration Flags for Peak Detection with External Comm Reset 36 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual SPDU Sub-Index Bit Position Flag Description Value 1 0 Slope 0 = Negative, 1 = Positive X* 2 1 Measurement 0 = Measurement 2, 1 = Measurement 1 X 3 2-3 ZERO Value 00 = Hold, 01 = Minimum, 10 = Maximum XX 4 4 Peak Detect 0 = Disabled, 1 = Enabled 1 5 5 Peak Detect Direction 0 = Maximum, 1 = Minimum X 6 6 Status 0 = Disabled, 1 = Enabled 1 7 7 Peak Detect Reset 0 = Auto, 1 = External Communications 1 * X denotes a don't care value 6.6.3 Channel States The Channel States section contains the state of all the channels in the EZ-ARRAY. Each sub-index represents 16 channels. SPDU Byte Position Member Name Index Sub-Index 65 1 0 Channels 1-8 65 1 1 Channels 9-16 65 ... ... ... 65 30 58 Channels 465-472 65 30 59 Channels 473-480 Channel States Bit-Mask Value State Description 0 Made The channel is made (clear) 1 Blocked The channel is blocked For example, if the first and third beams of the EZ-ARRAY are blocked, Sub-Index 1 would contain the value 0x0005. 6.6.4 System Info and Status The System Info and Status section contains the current status of the EZ-ARRAY. System Info and Status SPDU Byte Position Member Name Index Sub-Index 66 1 0-1 Number of Emitter Channels 66 2 2-3 Emitter First Bad Channel 66 3 4-5 Number of Receiver Channels 66 See Table B-12 8 DIP Switch 66 12 9 ERROR Code 66 13 10 Alignment Status 66 See Table B-14 11 Discrete Outputs 66 17 12-13 Analog Output 1 DAC 66 18 14-15 Analog Output 2 DAC www.bannerengineering.com - Tel: 763.544.3164 37 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Number of Emitter Channels Range Description 30-480 Number of channels the emitter has (multiples of 30) Emitter First Bad Channel Range Description 0-480 First channel that emitter is unable to fire (0 = no bad channels) Number of Receiver Channels Range Description 30-480 Number of channels the Receiver has (multiples of 30) DIP Switch SPDU Sub-Index Bit Position Function Description 5 0 DIP Switch 6 0 = ON, 1 = OFF 6 1 DIP Switch 5 0 = ON, 1 = OFF 7 2 DIP Switch 4 0 = ON, 1 = OFF 8 3 DIP Switch 3 0 = ON, 1 = OFF 9 4 DIP Switch 2 0 = ON, 1 = OFF 10 5 DIP Switch 1 0 = ON, 1 = OFF ERROR Code Value Status 0 System OK 1 Receiver EEPROM Hard Failure 2 Receiver Alignment/Blanking Configuration Error 3 Reserved for Factory 3 4 Emitter or Wiring Problem 5 Emitter Channel Error 6 Reserved for Factory 6 7 Reserved for Factory 7 8 Reserved for Factory 8 9 Reserved for Factory 9 10 Incompatible Scan and Measurement Mode Alignment Status 38 Value Status 0 Failed 1 Success www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual Discrete Outputs SPDU Sub-Index Bit Position Function Description 14 0 Discrete Output 1 0 = OFF, 1 = ON 15 1 Discrete Output 2 0 = OFF, 1 = ON Analog Output 1 DAC and Analog Output 2 DAC Range Description 0-4095 Current DAC value of analog output 6.6.5 Receiver and Emitter Version Info The Receiver and Emitter Version Info section contains the part numbers and versions of the receiver and emitter firmware. SPDU Byte Position Member Name Index Sub-Index 68 1 0-3 Receiver Part Number 68 2 4 Receiver Version 68 4 6-9 Emitter Part Number 68 5 10 Emitter Version 6.6.6 Communications Version Info The Communications Version Info section contains the part number and version of the communications firmware. SPDU Byte Position Member Name Index Sub-Index 69 1 0-3 Part Number 69 2 4 Version 6.6.7 Alignment/Blanking Routine The Alignment/Blanking Routine section provides a state-machine for executing the Alignment and/or Blanking routines. SPDU Index Sub-Index 92 1 Byte Position Member Name 0 Alignment / Blanking Mode Alignment/Blanking Mode Value State 0 IDLE State 1 Access Alignment Mode 2 Alignment State 3 Exit Alignment Mode 4 Access Blanking Mode 5 Blanking State 6 Exit Blanking Mode www.bannerengineering.com - Tel: 763.544.3164 39 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 1: Access Alignment Mode 4: Access Blanking Mode 2: Status: Alignment Mode 0: Idle 3: Exit Alignment Mode 5: Status: Blanking Mode 6: Exit Blanking Mode See Overview: Electronic Alignment Routine and Overview: Blanking for details on Alignment and Blanking routines. The Alignment Status can be read in the System Info and Status section to check if the Alignment routine was successful. 40 www.bannerengineering.com - Tel: 763.544.3164 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual 7 Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. 7.1 Contact Us Corporate Headquarters Address: Banner Engineering Corporate 9714 Tenth Avenue North Minneapolis, Minnesota 55441, USA Phone: +1 763 544 3164 Website: www.bannerengineering.com Europe Address: Banner Engineering EMEA Park Lane Culliganlaan 2F Diegem B-1831, Belgium Phone: +32 (0)2 456 0780 Website: www.bannerengineering.com/eu Email: mail@bannerengineering.com Turkey Address: Banner Engineering Turkey Barbaros Mah. Uphill Court Towers A Blok D:49 34746 Batı Ataşehir Istanbul Türkiye Phone: +90 216 688 8282 Website: www.bannerengineering.com.tr Email: turkey@bannerengineering.com.tr India Address: Banner Engineering India Pune Head Quarters Office No. 1001, 10th Floor Sai Capital, Opp. ICC Senapati Bapat Road Pune 411016, India Phone: +91 (0) 206 640 5624 Website: www.bannerengineering.co.in Email: salesindia@bannerengineering.com Mexico Address: Banner Engineering de Mexico Monterrey Head Office Edificio VAO Av. David Alfaro Siqueiros No.103 Col. Valle Oriente C.P.66269 San Pedro Garza Garcia, Nuevo Leon, Mexico Phone: +52 81 8363 2714 or 01 800 BANNERE (toll free) Website: www.bannerengineering.com.mx Email: mexico@bannerengineering.com Brazil Address: Banner do Brasil Rua Barão de Teffé nº 1000, sala 54 Campos Elíseos, Jundiaí - SP, CEP.: 13208-761, Brasil Phone: +1 763 544 3164 Website: www.bannerengineering.com.br Email: brasil@bannerengineering.com www.bannerengineering.com - Tel: 763.544.3164 41 A-GAGE® EZ-ARRAY™ IO-Link Instruction Manual China Address: Banner Engineering Shanghai Rep Office Xinlian Scientific Research Building Level 12, Building 2 1535 Hongmei Road, Shanghai 200233, China Phone: +86 212 422 6888 Website: www.bannerengineering.com.cn Email: sensors@bannerengineering.com.cn Japan Address: Banner Engineering Japan Cent-Urban Building 305 3-23-15 Nishi-Nakajima Yodogawa-Ku Osaka 532-0011, Japan Phone: +81 (0)6 6309 0411 Website: www.bannerengineering.co.jp Email: mail@bannerengineering.co.jp Taiwan Address: Banner Engineering Taiwan 8F-2, No. 308 Section 1, Neihu Road Taipei 114, Taiwan 42 Phone: +886 (0)2 8751 9966 Website: www.bannerengineering.com.tw Email: info@bannerengineering.com.tw www.bannerengineering.com - Tel: 763.544.3164
EA5R450XKQ 价格&库存

很抱歉,暂时无法提供与“EA5R450XKQ”相匹配的价格&库存,您可以联系我们找货

免费人工找货