T30SP6FF200Q

T30SP6FF200Q

  • 厂商:

    BANNER

  • 封装:

    -

  • 描述:

    PHOTO SEN 200MM COMP PNP

  • 数据手册
  • 价格&库存
T30SP6FF200Q 数据手册
T30 Sensors DC-Voltage Series Instruction Manual Self-Contained, DC-Operated Sensors • • • • • • Featuring EZ-BEAM® technology, specially designed optics and electronics provide reliable sensing without adjustments “T” style PBT polyester housing with 30 mm threaded lens in opposed, retroreflective, or fixedfield modes Completely epoxy-encapsulated providing superior durability, even in harsh sensing environments, rated to DIN IP69K Innovative dual-indicator system takes the guesswork out of sensor performance monitoring Advanced diagnostics warn of marginal sensing conditions or output overload 10 V dc to 30 V dc; choose SPDT (complementary) NPN or PNP outputs (150 mA maximum each) WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Sensing Mode Model1 Output T306E P POLAR RETRO FIXED-FIELD LED 60 m (196.8 ft) Infrared, 950 nm 6 m (19.7 ft) Visible red, 680 nm - T30SN6R OPPOSED Range NPN T30SP6R PNP T30SN6LP NPN T30SP6LP PNP T30SN6FF200 NPN T30SP6FF200 PNP T30SN6FF400 NPN T30SP6FF400 PNP T30SN6FF600 NPN T30SP6FF600 PNP 200 mm (7.9 in) cutoff 400 mm (15.7 in) cutoff Infrared, 880 nm 600 mm (23.6 in) cutoff Fixed-Field Mode Overview T30 self-contained fixed-field sensors are small, powerful, infrared diffuse mode sensors with far-limit cutoff (a type of background suppression). Their high excess gain and fixed-field technology allow detection of objects of low reflectivity, while ignoring background surfaces. The cutoff distance is fixed. Backgrounds and background objects must always be placed beyond the cutoff distance. Fixed-Field Sensing – Theory of Operation The T30 Fixed-Field sensor compares the reflections of its emitted light beam (E) from an object back to the sensor's two differently aimed detectors, R1 and R2. See Figure 1 on page 2. If the near detector's (R1) light signal is stronger than the far detector's (R2) light signal (see object A in the Figure below, closer than the cutoff distance), the sensor responds to the object. If the far detector's (R2) light signal is stronger than the near detector's (R1) light signal (see object B in the Figure below, beyond the cutoff distance), the sensor ignores the object. 1 Integral 2 m (6.5 ft) unterminated cable models are listed. • To order the 9 m (30 ft) PVC cable model, add the suffix "W/30" to the cabled model number. For example, T306E W/30. • To order the 4-pin M12/Euro-style integral quick disconnect model, add the suffix "Q" to the model number. For example, T306EQ. • Models with a quick disconnect require a mating cordset. Original Document 121524 Rev. C 2 October 2018 121524 T30 Sensors DC-Voltage Series The cutoff distance for the T30 is fixed at 200, 400, or 600 millimeters (7.9 inch, 16.7 inch, or 23.6 inch). Objects lying beyond the cutoff distance are usually ignored, even if they are highly reflective. However, under certain conditions, it is possible to falsely detect a background object (see Background Reflectivity and Placement on page 2). Receiver Elements Cutoff Distance Object B or Background Object A Lenses Near R1 Detector Far R2 Detector Emitter E R1 R2 Sensing Range Sensing Axis E Object is sensed if amount of light at R1 is greater than the amount of light at R2 Figure 1. Fixed-Field Concept Figure 2. Fixed-Field Sensing Axis In the drawings and information provided in this document, the letters E, R1, and R2 identify how the sensor's three optical elements (Emitter "E", Near Detector "R1", and Far Detector "R2") line up across the face of the sensor. The location of these elements defines the sensing axis, see Figure 2 on page 2. The sensing axis becomes important in certain situations, such as those illustrated in Figure 5 on page 3 and Figure 6 on page 3. Sensor Setup Sensing Reliability For highest sensitivity, position the target for sensing at or near the point of maximum excess gain. Maximum excess gain for all models occurs at a lens-to-object distance of about 40 mm (1.5 in). Sensing at or near this distance makes the maximum use of each sensor’s available sensing power. The background must be placed beyond the cutoff distance. Note that the reflectivity of the background surface also may affect the cutoff distance. Following these guidelines improves sensing reliability. Background Reflectivity and Placement Avoid mirror-like backgrounds that produce specular reflections. A false sensor response occurs if a background surface reflects the sensor's light more to the near detector (R1) than to the far detector (R2). The result is a false ON condition (Figure 3 on page 3). Correct this problem by using a diffusely reflective (matte) background, or angling either the sensor or the background (in any plane) so the background does not reflect light back to the sensor (Figure 4 on page 3). Position the background as far beyond the cutoff distance as possible. An object beyond the cutoff distance, either stationary (and when positioned as shown in Figure 5 on page 3), or moving past the face of the sensor in a direction perpendicular to the sensing axis, may cause unwanted triggering of the sensor if more light is reflected to the near detector than to the far detector. Correct the problem by rotating the sensor 90° (Figure 6 on page 3). The object then reflects the R1 and R2 fields equally, resulting in no false triggering. A better solution, if possible, may be to reposition the object or the sensor. 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 121524 Rev. C T30 Sensors DC-Voltage Series Cutoff Distance Cutoff Distance Reflective Background R1 = Near Detector R2 = Far Detector E = Emitter T30FF R1 R2 E T30FF R1 R2 E Strong Direct Reflection to R1 Core of Emitted Beam Reflective Background Fixed Sensing Field Fixed Sensing Field Core of Emitted Beam Strong Direct Reflection Away From Sensor R1 = Near Detector R2 = Far Detector E = Emitter Figure 3. Reflective Background - Problem Figure 4. Reflective Background - Solution Cutoff Distance T30FF Cutoff Distance T30FF R1 R2 E, R2, R1 E Fixed Sensing Field R1 = Near Detector R2 = Far Detector E = Emitter Fixed Sensing Field Reflective Background or Moving Object Reflective Background or Moving Object E = Emitter R2 = Far Detector R1 = Near Detector A reflective background object in this position or moving across the sensor face in this axis and direction may cause a false sensor response. A reflective background object in this position or moving across the sensor face in this axis is ignored. Figure 5. Object Beyond Cutoff - Problem Figure 6. Object Beyond Cutoff - Solution Color Sensitivity The effects of object reflectivity on cutoff distance, though small, may be important for some applications. It is expected that at any given cutoff setting, the actual cutoff distance for lower reflectance targets is slightly shorter than for higher reflectance targets. This behavior is known as color sensitivity. For example, an excess gain of 1 for an object that reflects 1/10 as much light as the 90% white card is represented by the horizontal graph line at excess gain = 10. An object of this reflectivity results in a far limit cutoff of approximately 190 mm (7.5 inch) for the 200 mm (8 inch) cutoff model, for example; and 190 mm represents the cutoff for this sensor and target. These excess gain curves were generated using a white test card of 90% reflectance. Objects with reflectivity of less than 90% reflect less light back to the sensor, and thus require proportionately more excess gain in order to be sensed with the same reliability as more reflective objects. When sensing an object of very low reflectivity, it may be especially important to sense it at or near the distance of maximum excess gain. Wiring Diagrams NPN Standard Cabled Emitters 3 3 1 P/N 121524 Rev. C – 1 10-30V dc 4 + 2 PNP Standard – 10-30V dc + Load Load 1 + 10-30V dc – 3 4 2 www.bannerengineering.com - Tel: +1-763-544-3164 Key: Wire 1 = Brown Wire 2 = White Wire 3 = Blue Wire 4 = Black Load Load 3 T30 Sensors DC-Voltage Series Quick Disconnect Emitters 1 NPN Alarm 1 + 10–30 V dc − 3 4 4 2 2 not used 3 – 10-30V dc + 3 not used PNP Alarm + 10-30V dc – 1 4 Load 2 Alarm Load Alarm Specifications Supply Protection Circuitry Protected against reverse polarity and transient voltages Supply Voltage and Current 10 V dc to 30 V dc (10% maximum ripple) Supply current (exclusive of load current): Emitters, Non-Polarized, Retro: 25 mA Receivers: 20 mA Polarized Retroreflective: 30 mA Fixed-Field: 35 mA Output Protection Circuitry Protected against output short-circuit, continuous overload, and false pulse on power-up Output Configuration SPDT solid-state dc switch; NPN or PNP outputs, depending on model Light Operate: N.O. output conducts when sensor sees its own (or the emitter’s) modulated light Dark Operate: N.C. output conducts when the sensor sees dark; the N.C. output may be wired as a normally open marginal signal alarm output, depending on wiring to power supply Output Rating 150 mA maximum each When wired for alarm output, the total load may not exceed 150 mA OFF-state leakage current: < 1 µA at 30 V dc ON-state saturation voltage: < 1 V at 10 mA dc; < 1.5 V at 150 mA dc Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. 4 Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Output Response Time Opposed mode: 3 ms ON, 1.5 ms OFF Retro, Fixed-Field and Diffuse: 3 ms ON and OFF Note: 100 ms delay on power-up; outputs do not conduct during this time Repeatability Opposed mode: 375 μs Retro, Fixed-Field and Diffuse: 750 μs Repeatability and response are independent of signal strength Indicators Two LEDs (Green and Amber) Green ON steady: power to sensor is ON Green flashing: output is overloaded Amber ON steady: N.O. output is conducting Amber flashing: excess gain marginal (1 to 1.5 times) in light condition Construction Housing: PBT polyester Lens: Polycarbonate (opposed-mode) or acrylic Environmental Rating Leakproof design rated NEMA 6P, DIN IP69K Connections 2 m (6.5 ft) or 9 m (30 ft) integral PVC cable or Integral 4-pin M12/Euro-style quick disconnect Operating Conditions Temperature: –40 °C to +70 °C (–40 °F to +158 °F) Humidity: 90% at +50 °C maximum relative humidity (non-condensing) Vibration and Mechanical Shock All models meet MIL-STD-202F, Method 201A (Vibration: 10 Hz to 60 Hz maximum, 0.06 inch (1.52 mm) double amplitude, 10G acceleration) requirements. Method 213B conditions H&I. (Shock: 75G with unit operating; 100G for non-operation) Certifications www.bannerengineering.com - Tel: +1-763-544-3164 P/N 121524 Rev. C T30 Sensors DC-Voltage Series Dimensions Cabled Models Quick Disconnect Models ø 40.0 mm (1.57") Jam Nut (Supplied) M30 x 1.5 Thread 45.0 mm (1.77") ø 15 mm (0.59") Green LED Power Indicator Amber LED Output Indicator 51.5 mm (2.03") 66.5 mm (2.62") 11.5 mm (0.45") Performance Curves Table 1: Opposed Mode Sensors Beam Pattern Excess Gain 1000 T30 Series 750 mm 30" Opposed Mode 500 mm 20" 250 mm 10" 0 0 250 mm 10" 500 mm 20" 750 mm 30" 0 15 m (50') 30 m (100') 45 m (150') 60 m (200') E X C E S S G A I N Opposed Mode 100 10 1 0.1 m (0.33') 75 m (250') T30 Series 1m (3.3') 10 m (33') 100 m (330') DISTANCE DISTANCE Table 2: Polarized Retro Mode Sensors2 Beam Pattern Excess Gain 1000 T30 Series 150 mm 6" Polarized Retro 100 mm 4" 50 mm 2" 0 0 with BRT-3 Reflector 50 mm 2" 100 mm 4" 150 mm 6" 0 1.5 m (5') 3.0 m (10') 4.5 m (15') 6.0 m (20') 7.5 m (25') E X C E S S G A I N Polarized Retro 100 with BRT-3 Reflector 10 1 0.01 m (0.033') DISTANCE 2 T30 Series 0.1 m (0.33') 1m (3.3') 10 m (33') DISTANCE Performance based on use of a model BRT-3 retroreflector (3-inch diameter). Actual sensing range may be more or less than specified, depending on the efficiency and reflective area of the retroreflector used. P/N 121524 Rev. C www.bannerengineering.com - Tel: +1-763-544-3164 5 T30 Sensors DC-Voltage Series Table 3: Fixed-Field Mode Sensor Excess Gain3 Fixed-Field – 200 mm 1000 E X C E S S Fixed-Field – 400 mm 1000 T30 Series E X C E S S 100 Fixed-field mode with 200 mm far limit cutoff G A I N 10 1 1 mm (0.04") G A I N 10 mm (0.4") 100 mm (4") 1000 mm (40") Fixed-Field – 600 mm 1000 T30 Series E X C E S S 100 Fixed-field mode with 400 mm far limit cutoff G A I N 10 1 1 mm (0.04") DISTANCE 10 mm (0.4") 100 mm (4") T30 Series 100 Fixed-field mode with 600 mm far limit cutoff 10 1 1 mm (0.04") 1000 mm (40") DISTANCE 10 mm (0.4") 100 mm (4") 1000 mm (40") DISTANCE Ø 16 mm spot size at 35 mm focus Ø 17 mm spot size at 35 mm focus Ø 17 mm spot size at 35 mm focus Ø 20 mm spot size at 200 mm cutoff Ø 25 mm spot size at 400 mm cutoff Ø 30 mm spot size at 600 mm cutoff Using 18% gray test card: cutoff distance Using 18% gray test card: cutoff distance Using 18% gray test card: cutoff distance will be 95% of value shown. will be 90% of value shown. will be 85% of value shown. Using 6% black test card: cutoff distance will be 90% of value shown. Using 6% black test card: cutoff distance will be 85% of value shown. Using 6% black test card: cutoff distance will be 75% of value shown. Accessories Cordsets 4-Pin Threaded M12/Euro-Style Cordsets Model Length MQDC-406 1.83 m (6 ft) MQDC-415 4.57 m (15 ft) MQDC-430 9.14 m (30 ft) MQDC-450 15.2 m (50 ft) MQDC-406RA 1.83 m (6 ft) MQDC-415RA 4.57 m (15 ft) MQDC-430RA 9.14 m (30 ft) Style Dimensions 44 Typ. Straight M12 x 1 ø 14.5 3 6 15.2 m (50 ft) 2 1 3 4 32 Typ. [1.26"] 30 Typ. [1.18"] Right-Angle MQDC-450RA Pinout (Female) 1 = Brown 2 = White 3 = Blue 4 = Black M12 x 1 ø 14.5 [0.57"] Performance based on use of a 90% reflectance white test card. Focus and spot sizes are typical. www.bannerengineering.com - Tel: +1-763-544-3164 P/N 121524 Rev. C T30 Sensors DC-Voltage Series Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. © Banner Engineering Corp. All rights reserved
T30SP6FF200Q 价格&库存

很抱歉,暂时无法提供与“T30SP6FF200Q”相匹配的价格&库存,您可以联系我们找货

免费人工找货