0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SI-RFA-P

SI-RFA-P

  • 厂商:

    BANNER

  • 封装:

    -

  • 描述:

    SI-RF TERMINATION PLUG M-12

  • 数据手册
  • 价格&库存
SI-RFA-P 数据手册
SI-RF Non-Contact RF Safety Switch Instruction Manual Original Instructions 208885 Rev. H 10 March 2021 © Banner Engineering Corp. All rights reserved 208885 SI-RF Non-Contact RF Safety Switch Contents 1 Product Overview .......................................................................................................................................................... 3 1.1 Models ..............................................................................................................................................................................................3 1.2 Important... Read this before proceeding! ........................................................................................................................................3 1.3 EU Declaration of Conformity (DoC) ................................................................................................................................................ 4 1.4 Overview ......................................................................................................................................................................................... 4 2 Configuration Instructions ...........................................................................................................................................5 2.1 Safety Code for Operation .............................................................................................................................................................. 5 2.2 Teach the Safety Code ................................................................................................................................................................... 5 3 Installation Instructions ............................................................................................................................................... 6 3.1 Installation Requirements .................................................................................................................................................................6 3.2 Pass-through hazards and Perimeter Guarding ..............................................................................................................................7 3.3 Mechanical Installation ....................................................................................................................................................................7 3.4 Sensing Distance ............................................................................................................................................................................ 8 3.5 Resetting the Inputs ........................................................................................................................................................................ 9 3.6 Auxiliary Output/Information ............................................................................................................................................................9 3.7 In-Series Diagnostic Information .....................................................................................................................................................9 3.8 Electrical Installation ..................................................................................................................................................................... 10 3.8.1 Protective Stop (Safety Stop) Circuits ................................................................................................................................... 10 3.8.2 Output Signal Switching Devices (OSSDs) and External Device Monitoring (EDM) .............................................................10 3.8.3 Wiring for Single PNP (SI-RFP) ..............................................................................................................................................11 3.8.4 Wiring for a Single 8-Conductor Sensor ................................................................................................................................ 12 3.8.5 Wire the Switch in Series .......................................................................................................................................................13 3.8.6 Wire the Switch in Series Using the Quick Disconnect ......................................................................................................... 14 4 Specifications 4.1 Dimensions 5 Accessories ............................................................................................................................................................. 17 .................................................................................................................................................................................... 18 ..................................................................................................................................................................19 5.1 Cordsets .........................................................................................................................................................................................19 5.2 Adapters and Other Accessories ................................................................................................................................................... 20 5.3 Safety Controllers ...........................................................................................................................................................................21 5.4 Universal (Input) Safety Modules ..................................................................................................................................................21 6 Product Support and Maintenance ........................................................................................................................... 22 6.1 Maintenance and Service ..............................................................................................................................................................22 6.2 Status Indicators ............................................................................................................................................................................ 22 6.3 Information Available via ISD ........................................................................................................................................................23 6.4 Contact Us ..................................................................................................................................................................................... 24 6.5 Banner Engineering Corp. Limited Warranty ................................................................................................................................ 25 SI-RF Non-Contact RF Safety Switch 1 Product Overview SI-RF Radio Frequency Safety Switch for interlocking and position monitoring • • • • • • Sensor - Actuator pair with Unique, High and Low code options One SI-RF Safety Switch will meet Cat 4, PL e, or SIL CL 3 safety ratings Series connection of up to 32 sensors, maintaining the highest levels of safety Diagnostic options include In-Series Diagnostic (ISD) bussed signals and on-sensor LED codes PNP auxiliary outputs on select models indicate door status Protection class rating of IP69 1.1 Models Model Device SI-RF Models Coding SI-RFST-UP8 Unique SI-RFST-HP8 High SI-RFST-LP8 Low SI-RFSL-UP8 Unique SI-RFSL-HP8 High SI-RFSL-LP8 Low SI-RFDT-UP8 Unique SI-RFDT-HP8 High Diagnostics Reset Connector Automatic Series PNP SI-RFDT-LP8 Low Sensor SI-RFDL-UP8 Unique SI-RFDL-HP8 High SI-RFDL-LP8 Low SI-RFPT-U2M Unique SI-RFPT-H2M High SI-RFPT-L2M Low SI-RFPT-UP5 Unique SI-RFPT-HP5 High SI-RFPT-LP5 Low Manual 250 mm cable with an 8-pin M12 quick disconnect Automatic In-Series Diagnostic (ISD) Manual 2 m cable Single PNP SI-RF-A Automatic 250 mm cable with an 5-pin M12 quick disconnect Actuator/target for all switches Actuator SI-RF-A2 Low Profile Actuator/target for all switches In addition to the SI-RF sensor, a basic SI-RF system requires an actuator, a cable and a safety monitoring device. 1.2 Important... Read this before proceeding! The user is responsible for satisfying all local, state, and national laws, rules, codes, and regulations relating to the use of this product and its application. Banner Engineering Corp. has made every effort to provide complete application, installation, operation, and maintenance instructions. Please contact a Banner Applications Engineer with any questions regarding this product. The user is responsible for making sure that all machine operators, maintenance personnel, electricians, and supervisors are thoroughly familiar with and understand all instructions regarding the installation, maintenance, and use of this product, and with the machinery it controls. The user and any personnel involved with the installation and use of this product must be www.bannerengineering.com - Tel: + 1 888 373 6767 3 SI-RF Non-Contact RF Safety Switch thoroughly familiar with all applicable standards, some of which are listed within the specifications. Banner Engineering Corp. makes no claim regarding a specific recommendation of any organization, the accuracy or effectiveness of any information provided, or the appropriateness of the provided information for a specific application. 1.3 EU Declaration of Conformity (DoC) Banner Engineering Corp. herewith declares that these products are in conformity with the provisions of the listed directives and all essential health and safety requirements have been met. For the complete DoC, please go to www.bannerengineering.com. Product Directive SI-RF Radio Frequency Safety Switch 2006/42/EC Representative in EU: Peter Mertens, Managing Director, Banner Engineering BV. Address: Park Lane, Culliganlaan 2F, bus 3,1831 Diegem, Belgium. 1.4 Overview Use the SI-RF Radio Frequency Safety Switch to monitor the position of a guard to detect its movement, opening, or removal. A "guard" can be a gate, door, cover, panel, barrier or other physical means that separates an individual from a hazard. Safety switches will issue a signal to the machine control system to prevent or stop (halt) hazardous situations when the guard is not in the proper position. The SI-RF Safety Switch is designed for non-locking guarding applications, unless another means of locking is provided. The SI-RF Safety Switch is considered a Type 4 interlocking device per ISO 14119 that are actuated by an electronic field interacting with the coded actuator typically mounted on the guard. Different levels of coded sensors are available: low, high, and unique. Applications involving the use of the SI-RF Safety Switch should take into consideration the following standards: • ISO 13849-1/2 - Safety of Machinery - Safety Related Parts of Control Systems • ISO 12100 - Safety of Machinery - Risk Assessment and Risk Reduction • ISO 14119 - Safety of Machinery - Interlocking Devices Associated with Guards • ANSI B11.0 - Safety of Machinery - General Requirements and Risk Assessment • ANSI B11.19 - Performance Criteria for Safeguarding The SI-RF Safety Switch can be used individually or in series. A series string can consist of 1 to 32 units. The redundant safety inputs are only used for the serial connection of sensors (for an individual unit or last in the string they get tied to +24 V dc). The redundant safety outputs can be used for serial connection of sensors or for the connection to the safety related parts of the control system. 4 www.bannerengineering.com - Tel: + 1 888 373 6767 SI-RF Non-Contact RF Safety Switch 2 Configuration Instructions 2.1 Safety Code for Operation The actuator of the SI-RF Safety Switch system has a non-modifiable safety code for distinct and error-free identification. This code must be submitted to the SI-RF Safety Switch and permanently saved in the SI-RF Safety Switch. Three different coding levels are available: • Low (L)—The SI-RF Safety Switch accepts any actuator. • High (H)—The SI-RF Safety Switch only accepts the last taught-in actuator, a maximum of 12 teach-in processes are possible. • Unique (U)—The SI-RF Safety Switch only accepts the taught-in actuator, and only one teach-in process is possible. 2.2 Teach the Safety Code 1. Position the new actuator in front of the SI-RF Safety Switch. 2. Energize the SI-RF Safety Switch for minimum 5 seconds. The amber and green LED on the SI-RF Safety Switch flash with flash code 6 for 1.5 seconds (see Status Indicators on p. 22). The new actuator code is stored temporarily. 3. Disconnect the SI-RF Safety Switch from supply voltage. 4. With the new actuator still positioned in front of the SI-RF Safety Switch, again energize the switch for a minimum of 5 seconds. The amber and the green LED on the SI-RF Safety Switch flash with flash code 6 for 3 seconds. The new actuator code is saved in the SI-RF Safety Switch. If a different actuator code is read on the second power-up, the temporarily stored code is lost and you must re-start the process. Note: If, after this process is followed, the Amber LED is still flashing BC1, disconnect the output wires. If the Amber LED turns on solid, the outputs could be shorted to a voltage source. www.bannerengineering.com - Tel: + 1 888 373 6767 5 SI-RF Non-Contact RF Safety Switch 3 Installation Instructions 3.1 Installation Requirements The following general requirements and considerations apply to the installation of interlocked gates and guards for the purpose of safeguarding. In addition, the user must refer to the relevant regulations and comply with all necessary requirements. See ANSI B11.19, or ISO 14119 and ISO 14120, or the appropriate standard. Hazards guarded by the interlocked guard must be prevented from operating until the guard is closed; a stop command must be issued to the guarded machine if the guard opens while the hazard is present. Closing the guard must not, by itself, initiate hazardous motion; a separate procedure must be required to initiate the motion. Locate the guard an adequate distance from the danger zone (so the hazard has time to stop before the guard is opened sufficiently to provide access to the hazard). Guard locking or supplemental safeguarding must be used if the overall stopping time of the machine or the time to remove the hazard is greater than the time to access the guarded area. The guard must open either laterally or away from the hazard, not into the safeguarded area. The guard also should not be able to close by itself and activate the interlocking circuitry. The installation must prevent personnel from reaching over, under, around or through the guard to access the hazard. Any openings due to positioning, movement, or misalignment in the guard must not allow access to the hazard—see ANSI B11.19, ISO 13855, ISO 13857, or the appropriate standard. The guard must be strong enough and designed to protect personnel and contain hazards within the guarded area that can be ejected, dropped, or emitted by the machine. Mount the SI-RF Safety Switch securely so that the physical position cannot shift, using reliable fasteners that require a tool to remove. Mounting slots in the housing, if provided, are for initial adjustment only; final mounting holes (round) must be used for permanent location. The switches, actuating systems, and actuators must not be used as a mechanical or end-of-travel stop. When the guard is closed, the actuator is guided to the sensor. When the switch on distance is reached, the sensor detects the actuator code. If the sensor detects an acceptable code it turns the output signal switch device (OSSD) safety outputs (OSSD1 and OSSD2) ON. When the guard is opened, the actuator is removed from the response range of the sensor. The sensor switches the safety outputs (OSSD1 and OSSD2) OFF. See Mechanical Installation on p. 7, Electrical Installation on p. 10, Switching Diagrams, and Specifications on p. 17 for additional information. Design and install the safety switches and actuators so that they cannot be easily defeated. Measures to minimize defeat (bypassing) of interlocking safety switches include: • Minimizing motivation for defeating interlocking by providing training, supervision, and efficient means for machine setup/adjustment, operation and maintenance • Limiting accessibility to the interlocking device, such as mounting out of reach, mounting behind a physical obstruction, mounting in a concealed position • Preventing the switch or the actuator from being disassembled or repositioned that compromises the safety function. (for example, welding, one-way screws, riveting) • Using hardware that requires a tool to remove that is not readily available. WARNING: • Properly Install the Interlocked Guards • Failure to follow these guidelines could result in serious injury or death. • At a minimum, the interlocked guard must prevent hazards when not fully closed and must prevent access to the hazards through any opening in the guard. • Install the safety switches and actuators so they cannot be easily defeated and are not used as a mechanical or end-of-travel stop. • The user must refer to the relevant regulations and comply with all necessary requirements. See ANSI B11.19, or ISO 14119 and ISO 14120, or the appropriate standard. CAUTION: • Do not use the safety switch as a mechanical or end-of-travel stop. • Catastrophic damage can cause the safety switch to fail in an unsafe manner (that is, loss of the switching action). • Limit the movement or rotation of the guard to prevent damage to the safety switch or the actuator. 6 www.bannerengineering.com - Tel: + 1 888 373 6767 SI-RF Non-Contact RF Safety Switch WARNING: • The hazard must be accessible only through the sensing field • Incorrect system installation could result in serious injury or death. • The installation of the SI-RF Safety Switch must prevent any individual from reaching around, under, over or through the defined area and into the hazard without being detected. • See OSHA CFR 1910.217, ANSI B11.19, and/or ISO 14119, ISO 14120 and ISO 13857 for information on determining safety distances and safe opening sizes for your guarding device. Mechanical barriers (for example, hard (fixed) guarding) or supplemental safeguarding might be required to comply with these requirements. 3.2 Pass-through hazards and Perimeter Guarding A pass-through hazard is associated with applications where personnel may pass through a safeguard (which issues a stop command to remove the hazard), and then continues into the guarded area, such as in perimeter guarding. Subsequently, their presence is no longer detected, and the related danger becomes the unexpected start or restart of the machine while personnel are within the guarded area. Eliminate or reduce pass-through hazards whenever possible—see ANSI B11.19 and ANSI B11.20 or ISO 11161. One method to mitigate the risk is to ensure that once tripped, either the safeguarding device, the safety related part of the control system, or the guarded machine's MSCs/MPCEs will latch in an OFF condition. The latch must require a deliberate manual action to reset that is separate from the normal means of machine cycle initiation. This method relies upon the location of the reset switch as well as safe work practices and procedures to prevent an unexpected start or restart of the guarded machine. All reset switches must be: • Outside the guarded area • Located to allow the switch operator a full, unobstructed view of the entire guarded area while the reset is performed • Out of reach from within the guarded area • Protected against unauthorized or inadvertent operation (such as through the use of rings or guards) If any areas within the guarded area are not visible from the reset switch, additional safeguarding must be provided. WARNING: • Perimeter guarding applications • Failure to observe this warning could result in serious injury or death. • Use lockout/tagout procedures per ANSI Z244.1, or use additional safeguarding as described by ANSI B11.19 safety requirements or other applicable standards if a passthrough hazard cannot be eliminated or reduced to an acceptable level of risk. 3.3 Mechanical Installation Important: Install a safety switch in a manner which discourages tampering or defeat. Mount switches to prevent bypassing of the switching function at the terminal chamber or Quick Disconnect (QD). A switch and its actuator must never be used as a mechanical stop. Overtravel may cause damage to switch. All mounting hardware is supplied by the user. Fasteners must be of sufficient strength to guard against breakage. Use of permanent fasteners or locking hardware is recommended to prevent the loosening or displacement of the actuator and the switch body. The mounting holes (4.5 mm) in the switch and actuator body accept M4 (#6) hardware. Mount the sensor and actuator such that the position cannot be changed after installation/adjustment. Mount the switch securely on a solid, stationary surface. Prevent the loosening of mounting hardware by using lock washers, thread-locking compound, etc. Only use slots for initial positioning. Pins, dowels, and splines can be used to prevent movement of the switch and the actuator. Install the SI-RF Safety Switch to prevent false or unintended actuation and intentional defeat. Locate the sensor and actuator to allow access for functional checks, maintenance, and service or replacement. The installation should provide suitable clearances, be readily accessible, and allow access to the actuator and sensor. CAUTION: Do not overtighten the units during installation. Overtightening can twist the housing and affect the sensors performance. www.bannerengineering.com - Tel: + 1 888 373 6767 7 SI-RF Non-Contact RF Safety Switch Important: It is the responsibility of the machine builder (user) to make sure the series wiring/cabling is not easily manipulated by an operator to defeat the safety function(s); for example, cannot remove a switch from the chain. 3.4 Sensing Distance Figure 1. Actuation directions 1 2 3 4 X The switching distances of the standard actuation direction 1 are listed. The distances noted are for a sensor working with the standard actuators (SI-RF-A and SI-RF-A2). Sensing Distance (Only in conjunction with actuator SI-RF-A) Minimum Rated sensing distance Sn Assured sensing distance - On Sao Hysteresis Typical 13 mm 10 mm H Assured sensing distance - Off Maximum 2 mm Sar 25 mm Within the detection range, there are "side lobes", in which the sensor can also activate. In an application with actuation direction 3, maintain a minimum distance X ≥ 5 mm between the SI-RF Safety Switch and actuator to ensure there is no activation within the side lobes. The specified sensing distances can only be reached if the following conditions are met: • Do not install the sensors near magnets or strong magnetic fields. • Do not flush mount the sensor and actuator to metallic materials. Metal can influence the sensing distances. Figure 2. Detection range Distance S (mm) 16.0 14.0 OFF Hysteresis 12.0 Switch OFF distance Switch ON distance 10.0 8.0 ON Important: When multiple units are mounted next to each other, there must be a minimum 100 mm distance between each sensor to ensure troublefree operation. 6.0 4.0 2.0 Side lobe -40 -30 -20 -10 0.0 0 Side lobe 10 -2.0 Offset S (mm) 8 www.bannerengineering.com - Tel: + 1 888 373 6767 20 30 40 SI-RF Non-Contact RF Safety Switch Figure 3. Sensor and actuator active areas Sensor Actuator Active areas Alignment marks Only authorized personnel should install these devices. Any of the shown mounting positions and approach directions may be used. Install the SI-RF Safety Switch so that the display is visible. The triangular symbols serve for the alignment and should point to each other. Immediately replace any damaged SI-RF Safety Switch or actuator components. They can be replaced separately, with the exception of the Unique (U) coded version. If you are using the Unique (U) coded version, the SI-RF Safety Switch and actuator must always be replaced together. 3.5 Resetting the Inputs The reset function forces a local confirmation that the safety outputs are switched on after closing the movable safety guard. If the moveable guard is opened using a sensor with a reset function, close and open the reset button within 0.25 seconds (minimum) to 1 second (maximum), after the guard has been closed. The reset function only applies to the sensor with the reset functionality. This reset feature allows for a local reset at a given guard but does not allow for an entire safety system reset. If a chain of sensors is cascaded (see Wire the Switch in Series on p. 13), the reset function only applies to SI-RF 3. If SI-RF 1 or 2 are opened then closed, the outputs will switch on after the guard is closed, without actuating the reset button. CAUTION: When power is switched on, the safety outputs switch on without actuating the reset button when the guard is in the closed position. WARNING: • Use of Auto or Manual Restart • Failure to follow these instructions could result in serious injury or death. • Application of power to the Banner device, the closing of the movable safety guard, or the reset of a manual restart condition MUST NOT initiate dangerous machine motion. Design the machine control circuitry so that one or more initiation devices must be engaged (in a conscious act) to start the machine - in addition to the Banner device going into Run mode. 3.6 Auxiliary Output/Information The PNP output models (SI-RFS and SI-RFP) have a diagnostic PNP output. The PNP Diagnostic is not safety related. The PNP Diagnostic output indicates whether the right actuator has been detected (for example, the door is closed). • Output high (conducting) - Actuator not detected • Output low (open or non-conducting) - Actuator detected When the SI-RFS sensors are cascaded, the output only signifies the actuator status of its sensor, not the others in the string. With manual reset models (SI-RFSL), the auxiliary output changes back to the low state when the actuator is sensed (does not wait for the reset). The ISD models (SI-RFD) do not have an auxiliary output. 3.7 In-Series Diagnostic Information The information transmitted via the In-Series Diagnostic (ISD) interface is not safety related. The diagnostic technology allows a wide range of sensor information to be loaded into the machine control system. To interpret the information, Banner diagnostic modules are available, including the SI-RF-DM1 and -DM2 Diagnostic Modules and the SC10-2roe Safety Controller. Refer to the instruction manuals for detailed information on the diagnostic devices. By means of diagnostics, the following information can be transmitted, among others: www.bannerengineering.com - Tel: + 1 888 373 6767 9 SI-RF Non-Contact RF Safety Switch • Door status (open, closed, or faulted) • Detection of misalignment (marginal signal strength of RF field) • Detection of under-voltages in the series connection • Attempts to defeat an RF gate switch For a complete list of the diagnostics information, see Information Available via ISD on p. 23. At this time this information can be refined via the following interfaces: • USB—display of the sensor information on the PC (requires using an SI-RF-DM1 Diagnostic Module or an SC10-2roe Safety Controller) • IO-Link—bus independent data reading into the control system (requires using the SI-RF-DM1 or SI-RF-DM2 Diagnostic Modules and an IO-Link master) • Industrial Ethernet Protocols—Bus data reading into the control system (requires using the SC10-2roe Safety Controller) 3.8 Electrical Installation WARNING: • Risk of electric shock • Use extreme caution to avoid electrical shock. Serious injury or death could result. • Always disconnect power from the safety system (for example, device, module, interfacing, etc.), guarded machine, and/or the machine being controlled before making any connections or replacing any component. Lockout/tagout procedures might be required. Refer to OSHA 29CFR1910.147, ANSI Z244-1, or the applicable standard for controlling hazardous energy. • Make no more connections to the device or system than are described in this manual. Electrical installation and wiring must be made by a Qualified Person 1 and must comply with the applicable electrical standards and wiring codes, such as the NEC (National Electrical Code), NFPA 79, or IEC 60204-1, and all applicable local standards and codes. 3.8.1 Protective Stop (Safety Stop) Circuits A protective stop (safety stop) allows for an orderly cessation of motion for safeguarding purposes, which results in a stop of motion and removal of power from the Machine Primary Control Elements (MPCE) (assuming this does not create additional hazards). A protective stop circuit typically comprises a minimum of two normally open contacts from forced-guided, mechanically linked relays, which are monitored through External Device Monitoring (EDM) to detect certain failures, to prevent the loss of the safety function. Such a circuit can be described as a "safe switching point". Typically, protective stop circuits are either single channel, which is a series connection of at least two normally open contacts; or dual-channel, which is a separate connection of two normally open contacts. In either method, the safety function relies on the use of redundant contacts to control a single hazard. If one contact fails On, the second contact arrests the hazards and prevents the next cycle from occurring. The interfacing of the protective stop circuits must be accomplished so that the safety function cannot be suspended, overridden, or defeated, unless accomplished in a manner of the same or greater degree of safety as the machine's safety related control system that includes the SI-RF Safety Switch. A Banner XS26-2 Safety Controller with XS1ro or XS2ro Relay Expansion Module, Banner SC10-2roe Safety Controller, or Banner UM-FA-xA Universal Safety Module provides a series connection of redundant contacts that form protective stop circuits for use in either single-channel or dual-channel control. 3.8.2 Output Signal Switching Devices (OSSDs) and External Device Monitoring (EDM) The SI-RF Safety Switch is able to detect faults on OSSD1 and OSSD2. These faults include short circuits to +24 V dc and 0 V, and between OSSD1 and OSSD2. Both OSSD outputs must be connected to the machine control so that the machine's safety-related control system interrupts the circuit or power to the machine primary control element(s) (MPCE), resulting in a non-hazardous condition. Final switching devices (FSDs) typically accomplish this when the OSSDs go to an OFF state. Refer to the output specifications and these warnings before making OSSD output connections and interfacing the SI-RF Safety Switch to the machine. 1 10 A person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work. www.bannerengineering.com - Tel: + 1 888 373 6767 SI-RF Non-Contact RF Safety Switch WARNING: Interfacing of Both OSSDs Both OSSD (Output Signal Switching Device) outputs must be connected to the machine control so that the machine’s safety-related control system interrupts the circuit to the machine primary control element(s), resulting in a non-hazardous condition. Never wire an intermediate device(s) (for example, PLC, PES, or PC) that can fail in such a manner that there is the loss of the safety stop command, OR in such a manner that the safety function can be suspended, overridden, or defeated, unless accomplished with the same or greater degree of safety. Failure to follow these instructions could result in serious injury or death. WARNING: OSSD Interfacing To ensure proper operation, the Banner device output parameters and machine input parameters must be considered when interfacing the Banner device OSSD outputs to machine inputs. Machine control circuitry must be designed so that the maximum load resistance value is not exceeded and that the maximum specified OSSD Off-state voltage does not result in an On condition. Failure to properly interface the OSSD Outputs to the guarded machine could result in serious injury or death. External device monitoring (EDM) is a function used to monitor the state of the external, positively guided (mechanically linked) machine control contacts (Final Switching Devives (FSD) and/or MPCEs). The SI-RF Safety Switch does not include the EDM function. As a result, the SI-RF Safety Switch should be used with an external safety monitoring device that monitors the status of the two SI-RF Safety Switch OSSDs and is capable of providing the EDM function. Examples of appropriate external safety monitoring devices include Banner SC10-2roe, SC26-2, and XS26-2 Safety Controllers; Banner UM-FA-9A and UM-FA-11A Universal Input Safety Modules; and Safety PLCs. WARNING: • The SI-RF Safety Switch does not have external device monitoring (EDM). • If EDM is required for the application, it must be implemented in the external control. Fault-Tolerant Output Feature Faults that do not immediately compromise the safe operation of the SI-RF Safety Switch (for example safety output to external potential, crosswire short safety output) result in a delayed switch-off of the safety outputs. The safety outputs switch off when the error warning exceeds 20 minutes. In case of error warning, the red LED flashes code BC2. Use this fault-tolerant output feature to run down the machinery in a controlled manner. After fixing the fault, the error message is confirmed by a voltage reset. The safe outputs enable and allow a restart. 3.8.3 Wiring for Single PNP (SI-RFP) Five-conductor, cannot be wired in series A movable safety guard is monitored through one SI-RF Safety Switch. The safety outputs of the SI-RF Safety Switch are connected to a safety monitoring module. When the safety guard is closed (actuator detected), the SI-RF Safety Switch switches on its safety outputs. When being used individually, the SI-RFP series offers a simple 5-pin wiring scheme. Use the optional PNP auxiliary output to transfer non-safety related status information. Pin Wire Color SI-RFPT-xP5 SI-RFPT-x2M 1 Brown +24 V DC +24 V DC 2 White OSSD1 OSSD1 3 Blue 0 V DC 0 V DC 4 Black OSSD2 OSSD2 5 Gray PNP OUT* PNP OUT* * Auxillary Output www.bannerengineering.com - Tel: + 1 888 373 6767 11 SI-RF Non-Contact RF Safety Switch Figure 4. Wiring for a single PNP +24Vdc XS/SC26-2xx XS2so or XS4so SI-RFPT..M + Do Q1 Q2 – 0Vdc +24Vdc 1 - Brown +24 V dc 5 - Grey PNP OUT * 2 - White OSSD1 4 - Black OSSD2 3 - Blue 0V dc 0Vdc LOAD IN1 SO1a IN2 (SO1 not split) FSD1 FSD2 SO1b * Auxillary Output EDM Single-Channel Safety Stop Circuit Dual-Channel Safety Stop Circuit 3.8.4 Wiring for a Single 8-Conductor Sensor The 8-pin sensors have one pair of OSSD outputs (Q1/Q2), one pair of inputs (I1/I2) that must be high (+24 V DC) before the outputs can turn on, one +24 V DC input, and one 0 V DC input. Some models have a reset input that receives +24 V DC to reset the unit. Some models have an Auxillary PNP output (Do). The following table describes the wiring of the different model options. Pin/Wire Function SXA-8xxD Wire Color SI-RFST-xP8 SI-RFSL-xP8 SI-RFDT-xP8 SI-RFDL-xP8 1 White +24 V DC +24 V DC +24 V DC +24 V DC 2 Brown OSSD1 OSSD1 OSSD1 OSSD1 3 Green 0 V DC 0 V DC 0 V DC 0 V DC 4 Yellow OSSD2 OSSD2 OSSD2 OSSD2 5 Grey Input1 Input1 Input1 Input1 6 Pink Input2 Input2 Input2 Input2 7 Blue PNP OUT* PNP OUT* No Function No Function 8 Red No Function Reset (+ In) No Function Reset (+ In) Pin * Auxillary Output 12 www.bannerengineering.com - Tel: + 1 888 373 6767 SI-RF Non-Contact RF Safety Switch Figure 5. Wiring for a single 8-conductor sensor +24Vdc 0Vdc SI-RFxT-xP8 + 1 - White I1 5 - Grey +24 V dc SC10 6 - Pink I2 Q1 Q2 – 2 - Brown OSSD1 4 - Yellow OSSD2 3 - Green 0V dc 7 - Blue n.c. 8 - Red n.c. +24Vdc 0Vdc IN3 IN4 L1/+V Machine Control Circuit EDM 13 14 23 24 33 34 L2/-V MPCE1 MPCE2 Arc Suppressors Safety Relay Outputs 43/44, 53/54 and 63/64 can be wired similarly, but require a separate EDM or AVM input for monitoring. Feedback Loop (optional) 3.8.5 Wire the Switch in Series To monitor several movable safety guards with a series connection of SI-RF Safety Switch, follow these steps. 1. Connect the safety outputs of the last SI-RF Safety Switch to a safety monitoring unit. 2. Connect the safety inputs of the first SI-RF Safety Switch of the series to + 24 V DC. 3. Connect the safety outputs of the first SI-RF Safety Switch to the safety inputs of the second SI-RF Safety Switch (and second to third, etc). 4. When all the safety guards are closed (all actuators are detected), the last SI-RF Safety Switch of the series connection switches on its safety outputs. 5. If you are using an optional In-Series Diagnostic (ISD) device (SI-RFD series), integrate the diagnostic device between the last SI-RF Safety Switch and the safety monitoring module in the series connection. The status information can then be retrieved from the diagnostic device. Note: Verify the SI-RF Safety Switch and the safety monitoring module are powered from the same power supply or the commons of the separate supplies are the same. If you are using the optional PNP auxiliary output (SI-RFS series), only the non-safety related status information of each individual sensor can be obtained. After the door is closed, the optional reset function requires a manual acknowledgement before the safety output of the sensor is switched on (only that individual sensor, not the series string). Figure 6. Wiring the switch in series SI-RF 1 n.c. 8 Rd + I2 1 Wh 6 Pk SI-RF 2 I1 Do Q1 Q2 5 Gy 7 Bu 24V 2 Bn – 4 Ye n.c. 3 Gn 8 Rd + I2 1 Wh 6 Pk SI-RF 3 I1 Do Q1 Q2 5 Gy 7 Bu 24V PNP/ OUT 2 Bn – 4 Ye + 3 Gn I2 1 Wh 6 Pk I1 Reset Do Q1 Q2 5 Gy 8 Rd 7 Bu 2 Bn – 4 Ye 3 Gn 24V PNP/ OUT www.bannerengineering.com - Tel: + 1 888 373 6767 PNP/ OUT Safety Controller 13 SI-RF Non-Contact RF Safety Switch 3.8.6 Wire the Switch in Series Using the Quick Disconnect Use models SI-RFS and SI-RFD for this configuration. When connecting units in series, simplify the wiring using special t-adapters and low cost unshielded four-wire double-ended cables. A similar configuration is shown except the connections are all made using quick disconnects. The SSAEB1PLx-0Dx E-stops, SI-RFD switches, and the SSA-ISD Connect can be combined in a single chain. 1. Connect the female 4-pin M12-Euro-style cable to the male 4-pin M12/Euro-style of the series connection t-adapter (SI-RFA-TS). 2. If a manual reset model sensor is used, connect the female 8-pin M12/Euro-style of the Reset T-Adapter (SI-RFATK) to the male 8-pin M12/Euro-style connector of the series connection t-adapter. Connect a female 4-pin M12/ Euro-Style cable to the male 4-pin M12/Euro-style QD of the t-adapter for connecting a reset switch or reading the Auxiliary output. 3. Connect the sensor to the male 8-pin M12 connector of the t-adapter. 4. Connect the male 4-pin M12 end of a double ended cable to the female 4-pin M12 of the t-adapter. Connect the female 4-pin M12 end of the double ended cable to the next series connection t-adapter (SI-RFA-TS). 5. At the end of the line a terminating plug (SI-RFA-P) is required to properly truncate the system. 6. The wired end of the 4-pin M12 cable (from step 1) can be wired directly to a Safety Monitoring Module or can be wired through an In-Series Diagnostic (ISD) module then to the Safety Monitoring device. Verify that the SI-RF Safety Switch and the safety monitoring module are powered from the same power supply or the commons of the separate supplies are the same. Ensure that the voltage level at SI-RF 1 (furthest from the power supply) is above 19.5 V for the system to operate properly. Figure 7. Wiring the switch in series using the quick disconnect connector Bk PNP Aux Output NOT FOR SAFETY 2 MQDC-4xx 4 Power MQDEC-4xxSS SI-RFA-P MQDEC-4xxSS SI-RFA-TK MQDEC-4xxSS MQDEC-4xxSS 24Vdc 0Vdc Safety Monitoring Module MQDC-4xx Bn Bu Wh SI-RFA-TS SI-RFA-TS Component Key SI-RFA-TS SI-RFA-TS Reset ONLY FOR DOOR 4 0Vdc 3 1 24Vdc SI-RFA-TK MQDC-4xx 4-pin male connection OSSDs Bk Bn Wh SI-RFA-TK SI-RFA-TS 8-pin female connection SI-RFA-P Termination MQDEC-4xxSS (4 lengths) MQDC-4xx (4 lengths) In long chains, or chains with a lot of ISD devices, the voltage at the first device (device closest to terminating plug) must stay above 19.5 V for the chain to operate properly. For guidance on maximum total cable length and maximum number of devices before an additional power supply may be needed, refer to Figure 10 on p. 15. For using ISD information to monitor the individual device voltages, see In-Series Diagnostic Information on p. 9. An additional power supply may be required to maintain a minimum of 19.5 V at all devices. There are two options to connect an additional power supply. 14 www.bannerengineering.com - Tel: + 1 888 373 6767 SI-RF Non-Contact RF Safety Switch Figure 8. Option 1: Use a SI-RFA-TK Reset Connector in series with ISD Device. If available, set the power supplies for parallel output. 8 Power #1 24Vdc 0Vdc SI-RFA-TK Bn 24Vdc 0Vdc Bu SI-RFA-P Bn Safety Monitoring Module Bu OSSDs Wh MQDEC-4xxSS SI-RFA-TS SI-RFA-TS SI-RFA-TS SI-RFA-TS SI-RFA-TS 0Vdc Power #2 24Vdc 1 Bk SI-RFA-TS Figure 9. Option 2: Replace the terminator with a power supply. The OSSD1 and OSSD2 wires at power supply #2 must be connected to +24 V DC. If available, set the power supplies for parallel output. Bu 24Vdc 0Vdc Bn Bn Safety Monitoring Module Bu Wh Connect OSSD1 and OSSD2 (white and black lines) to +24 V dc. SI-RFA-TS MQDEC-4xxSS SI-RFA-TS SI-RFA-TS SI-RFA-TS SI-RFA-TS 0Vdc DEER2-8xxD 24Vdc Power #1 24Vdc 0Vdc 8 1 Power #2 OSSDs Bk SI-RFA-TS Figure 10. Maximum total cable length for a single power supply Max. Total Series Cable (m) Single Power Supply Max. Total Series Cable (m) 160 140 120 SI-RF 100 80 E-Stops 60 40 20 0 0 4 8 12 16 20 24 Number of ISD Devices 28 32 The SI-RFD switches and the ISD Connect have similar current demands. However, when used with a number of lighted ISD emergency stop devices, the current draw of the emergency stop devices governs the cable lengths and when more power is needed. www.bannerengineering.com - Tel: + 1 888 373 6767 15 SI-RF Non-Contact RF Safety Switch WARNING: • Safety devices with OSSDs and without ISD, such as safety light curtains, are not compatible. • Failure to follow these instructions could result in serious injury or death. • Do not use safety devices with OSSDs and without ISD in a series connection of multiple ISD devices. 16 www.bannerengineering.com - Tel: + 1 888 373 6767 SI-RF Non-Contact RF Safety Switch 4 Specifications Important: The SI-RF Safety Switch should be connected only to a SELV (Safety Extra-Low Voltage), for circuits without earth ground or a PELV (Protected Extra-Low Voltage), for circuits with earth ground power supply, according to EN/IEC 60950. Rated supply voltage (Ue) 24 V; +25 %, - 20 % Reverse polarity protection The external voltage supply must be capable of buffering brief mains interruptions of 20 ms, as specified in IEC/EN 60204-1 Rated conditional short-circuit current 100 A Switching frequency ≤ 1 Hz No-load current (I0) ≤ 50 mA Switch-off delay (ta) 100 ms maximum + (7 ms × number of following ISD devices) Rated impulse withstand voltage (Uimp) 500 V Transponder frequency 125 kHz Time delay (tv) Maximum 2 s Protection Class according to EN IEC 61558 III Repeatability (R) 0.1 x Sn Enclosure PA66 + PA6, Red Shock and Vibration according to EN IEC 60947-5-2 EMC according to EN IEC 60947-5-3 and EN 61326-3-1 Environmental Rating IEC IP69 Construction Tension Relief: TPE, black Cable: PUR, black Rated isolation voltage (Ui) 75 V DC Ambient and Storage temperature –25 °C to +70 °C (–13 °F to +158 °F) Altitude ≤ 2000 m NHN Q1 and Q2 Safety Output Voltage level: according to Typ 3 EN 61131-2 Rated Operating Current (Ie): 100 mA Test Pulse Duration: 70 µs Test Pulse Rate: 1 s Maximum Capacitive Load: 100 nF Switching Elements: Sustained short-circuit and overload protection Type of Short Circuit Protection: thermal / digital (clocking) Switching Element Function: PNP, Normally Open Leakage Current (Ir): ≤ 1 mA DC Voltage Drop (Ud): ≤ 3 V Use Category: DC-13 Safety Data Up to PL (e) Category 4 PFHD 6 × 10-9 1/h SIL CL 3 Service Life: 20 years according to EN ISO 13849-1 according to DIN EN 62061 PNP/OUT Auxiliary Output Rated Operating Current (Ie): 10 mA Voltage Drop (Ud): ≤ 3 V Switching Elements: Sustained short-circuit and overload protection Type of Short Circuit Protection : current limited Maximum Relative Humidity 93% at 40 °C without condensation Indication 1 × LED red/green operating state 1 × LED amber actuating state Mounting 2 holes Ø 4,5 (for M4 screws) Standards EN 60947-1, EN 60947-5-2, EN 61326-3-1 EN ISO 13849-1, EN 62061, EN 60947-5-3, EN ISO 13849-2 EN 60204-1, ETSI EN 301489-1, ETSI EN 300330-1 Directive 2006/42/EG (Safety-of-Machinery-Directive) 2014/53/EU (RED) 2011/65/EU (RoHS II) 2014/30/EU (EMC) 2012/19/EU (EU-WEEE II) Approvals and Certifications TÜV Nord, cCSAus (class 2 Power source) FCC ID: 2ABA6SRF IC: 11535A-SRF FCC/IC Requirements: This device complies with Industry Canada licence-exempt RSS standard(s) and part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment. www.bannerengineering.com - Tel: + 1 888 373 6767 17 SI-RF Non-Contact RF Safety Switch 4.1 Dimensions All measurements are listed in millimeters, unless noted otherwise. Figure 11. SI-RF Safety Switch Sensor 26 15 19 4 Figure 12. SI-RF Safety Switch Actuator (7) Ø4.5 22 36 15 26 19 4 Ø8.1 (7) 36 7.6 Ø4.5 Ø8.1 Figure 13. SI-RF Safety Switch -A2 Actuator 18 18 36 22 (7) 2X Ø4.3 18 3.6 www.bannerengineering.com - Tel: + 1 888 373 6767 22 SI-RF Non-Contact RF Safety Switch 5 Accessories 5.1 Cordsets 8-Pin Threaded M12 Cordsets—Flying Leads Model Length SXA-815D 4.57 m (15 ft) SXA-825D 7.62 m (25 ft) Style Dimensions Pinout (Female) 2 1 7 6 44 Typ. SXA-850D 15.24 m (50 ft) Straight M12 x 1 ø 14.5 SXA-8100D 3 4 30.48 m (100 ft) 5 8 1 = White 5 = Gray 2 = Brown 6 = Pink 3 = Green 7 = Blue 4 = Yellow 8 = Red 5-Pin Threaded M12 Cordsets—Single Ended Model MQDC1-501.5 Length Style 0.5 m (1.5 ft) MQDC1-506 2 m (6.5 ft) MQDC1-515 5 m (16.4 ft) MQDC1-530 9 m (29.5 ft) MQDC1-506RA 2 m (6.5 ft) MQDC1-515RA 5 m (16.4 ft) Dimensions 44 Typ. Straight M12 x 1 ø 14.5 2 1 3 5 4 32 Typ. [1.26"] 9 m (29.5 ft) 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray 30 Typ. [1.18"] Right-Angle MQDC1-530RA Pinout (Female) M12 x 1 ø 14.5 [0.57"] 4-Pin Threaded M12 Cordsets—Single Ended Model Length MQDC-406 2 m (6.56 ft) MQDC-415 5 m (16.4 ft) MQDC-430 9 m (29.5 ft) MQDC-450 15 m (49.2 ft) MQDC-406RA 2 m (6.56 ft) MQDC-415RA 5 m (16.4 ft) MQDC-430RA 9 m (29.5 ft) MQDC-450RA 15 m (49.2 ft) Style Dimensions Pinout (Female) 44 Typ. Straight M12 x 1 ø 14.5 1 4 2 3 32 Typ. [1.26"] 30 Typ. [1.18"] Right-Angle M12 x 1 ø 14.5 [0.57"] www.bannerengineering.com - Tel: + 1 888 373 6767 1 = Brown 2 = White 3 = Blue 4 = Black 19 SI-RF Non-Contact RF Safety Switch 4-Pin Threaded M12 Cordsets—Double Ended Model Length MQDEC-401SS 0.31 m (1 ft) MQDEC-403SS 0.91 m (2.99 ft) MQDEC-406SS 1.83 m (6 ft) MQDEC-412SS 3.66 m (12 ft) MQDEC-420SS 6.10 m (20 ft) MQDEC-430SS 9.14 m (30.2 ft) MQDEC-450SS 15.2 m (49.9 ft) MQDEC-403RS 0.91 m (2.99 ft) MQDEC-406RS 1.83 m (6 ft) MQDEC-412RS 3.66 m (12 ft) MQDEC-420RS 6.10 m (20 ft) MQDEC-430RS 9.14 m (30.2 ft) Style Dimensions Pinout 40 Typ. [1.58"] Female M12 x 1 ø 14.5 [0.57"] Male Straight/ Female Straight 44 Typ. [1.73"] 2 1 3 4 M12 x 1 ø 14.5 [0.57"] Male 1 2 32 Typ. [1.26"] 30 Typ. [1.18"] Male Right-Angle/ Female Straight 4 3 1 = Brown 2 = White 3 = Blue 4 = Black M12 x 1 ø 14.5 [0.57"] ø 14.5 [0.57"] MQDEC-450RS 44 Typ. [1.73"] 15.2 m (49.9 ft) M12 x 1 8-Pin Threaded M12 Cordsets—Double Ended Model (8-pin/8-pin ) 2 DEE2R-81D Length 0.91 m (3 ft) DEE2R-88D 2.44 m (8 ft) 7.62 m (25 ft) DEE2R-850D 15.24 m (50 ft) Female Female Straight/ Male Straight 3 4 1 7 6 40 Typ. 44 Typ. 22.86 m (75 ft) 30.48 m (100 ft) 5 8 Male M12 x 1 ø 14.5 M12 x 1 ø 14.5 DEE2R-8100D Pinout 2 4.57 m (15 ft) DEE2R-825D DEE2R-875D Dimensions 0.3 m (1 ft) DEE2R-83D DEE2R-815D Style 1 2 3 4 7 6 8 5 1 = White 5 = Gray 2 = Brown 6 = Pink 3 = Green 7 = Blue 4 = Yellow 8 = Red 5.2 Adapters and Other Accessories Model Description SI-RFA-TS SI-RF T-adapter for series connection, 4 pin to 8 pin to 4 pin 2 Standard cordsets are yellow PVC with black overmold. For black PVC and overmold, add the suffix "B" to the model number (example, DEE2R-81DB) 20 www.bannerengineering.com - Tel: + 1 888 373 6767 SI-RF Non-Contact RF Safety Switch Model Description SI-RFA-TK SI-RF T-adapter for connection of the reset button, 8 pin to 4 pin to 8 pin SI-RFA-P SI-RF Termination plug M12 SI-RFA-DM1 SI-RF Diagnostic Module with 8 digital outputs and 1 diagnostic circuit Interfaces: IO-Link, USB 2.0 SI-RDA-DM2 SI-RF Diagnostic Module with 1 diagnostic circuit Interfaces: IO-Link 5.3 Safety Controllers Safety Controllers provide a fully configurable, software-based safety logic solution for monitoring safety and non-safety devices. For additional models and XS26 expansion modules, see instruction manual p/n 174868 (XS/SC26-2). Non-Expandable Models Expandable Models Description SC26-2 XS26-2 26 convertible I/O and 2 Redundant Solid State Safety Outputs SC26-2d XS26-2d 26 convertible I/O and 2 Redundant Solid State Safety Outputs with Display SC26-2e XS26-2e 26 convertible I/O and 2 Redundant Solid State Safety Outputs with Ethernet SC26-2de XS26-2de 26 convertible I/O and 2 Redundant Solid State Safety Outputs with Display and Ethernet SC10-2roe 10 Inputs, 2 redundant relay safety outputs (3 contacts each) (ISD compatible) 5.4 Universal (Input) Safety Modules UM-FA-xA Safety Modules provide forced-guided, mechanically-linked relay (safety) outputs for the SI-RF Safety Switch system when an external manual reset (latch) is desired or external device monitoring is required in the application. See datasheet p/n 141249 for more information. Model Description UM-FA-9A 3 normally open (N.O.) redundant-output 6 amp contacts UM-FA-11A 2 normally open (N.O.) redundant-output 6 amp contacts, plus 1 normally closed (N.C.) auxiliary contact www.bannerengineering.com - Tel: + 1 888 373 6767 21 SI-RF Non-Contact RF Safety Switch 6 Product Support and Maintenance 6.1 Maintenance and Service Remove all contamination by metal-based materials to avoid reducing the switch distance. Do not use alcoholic cleaning agents. The SI-RF Safety Switch is maintenance-free. For long-term and trouble-free operation, please periodically check the following points: • solid fit of all components • reliable switching function • if damage occurs, please exchange the relevant components Liability disclaimer— By breach of the given instructions (concerning the intended use, the safety instructions, the installation and connection through qualified personnel and the testing of the safety function) manufacturer’s liability expires. 6.2 Status Indicators Status Indicators Information for Operating status LEDs Actuator Color Green Amber Input Power/ Fault Teaching Error Status Meaning On Sensor OK Flashing (BC1) Reset expected (only with reset input) Flashing (BC2) Input function not fulfilled On Actuator in range, correct code Flashing (BC5) Actuator at detection limit Flashing (BC2) Actuator in range, wrong code Flashing (BC1) Actuator not taught-in Off Actuator out of range Flashing (BC6 for 1.5 s) Actuator code successfully temporary stored Flashing (BC6 for 3 s) Actuator code successfully stored On Failure in voltage monitoring Flashing (BC2) OSSD fault detected (switch off after specified time) Flashing (BC4) Internal fault (operation possible again after power reset) Green; amber Red T1 = 250 ms T2 = 250 ms T3 = 750 ms T4 = 500 ms T5 = 500 ms Figure 14. Flash code sequence BC1 BC2 BC3 BC4 BC5 BC6 t2 22 www.bannerengineering.com - Tel: + 1 888 373 6767 SI-RF Non-Contact RF Safety Switch 6.3 Information Available via ISD The following information can been obtained from the ISD chain and a diagnostic unit or ISD enable Safety Controller. Table 1: Cyclic Data about the Chain Short Name Data Format Meaning of data Count Mismatch 1/0 The number of devices in the chain does not match the configuration Order Mismatch 1/0 The order of the devices in the chain does not match the configuration No ISD Data Detected 1/0 No (or corrupted) ISD data being transmitted (being received by diagnostic device) Incompatible Device 1/0 The chain or a unit in the chain has data but not ISD data ISD detected not configured 1/0 ISD data is detected on inputs that are not configured as ISD input Terminator Missing 1/0 Terminator plug not present (or inputs to first device low) Actuator not taught 1/0 Unique or high unit has not been taught an actuator Wrong actuator detected 1/0 Wrong actuator presented to a unique or high coded sensor Internal unit error 1/0 A unit in the chain has an internal error Output fault detected 1/0 A unit in the chain has an output fault and will turn off after the switch off delay period Table 2: Individual Unit Data—Flags Short Name Data Format Meaning of data Actuator Detected 1/0 The SI-RF sensor detects an actuator Note: It does not have to be the taught actuator. Wrong Actuator 1/0 SI-RF sensor detects an actuator with a "received code" that does not match the "expected code". For code values, see Table 4 on p. 24. Sensor not paired 1/0 High or Unique sensor that has not been taught an actuator Output 1 1/0 Output 1 is On Output 2 1/0 Output 2 is On Marginal Range 1/0 An actuator is detected but is staying at the extreme end of the detection range (13 mm to 15 mm away from the sensor) Input 1 1/0 ISD device input 1 is On Input 2 1/0 ISD device input 2 is On Local Reset Expected 1/0 An ISD device with the latch feature requires a reset Operating Voltage Warning 1/0 Voltage to the ISD device is at the limit of specifications ISD Data Error 1/0 ISD error bit, corrupted data was received from the SI-RF ISD chain of switches Safety Input Fault 1/0 The system detected a fault on a safety input of an ISD device, power cycle required Output Error 1/0 ISD Device detects an output short to voltage or ground. This starts the "output switch-off timer" counter. For code values, see Table 4 on p. 24. Operating Voltage Error 1/0 Voltage to the ISD Device is above (over 30 V DC) or below (less than 19.2 V DC) limit of range www.bannerengineering.com - Tel: + 1 888 373 6767 23 SI-RF Non-Contact RF Safety Switch Short Name Data Format Meaning of data Power Cycle Required 1/0 ISD Device detects a fault, a power cycled required Table 3: Individual Unit Data—Configuration Short Name Data Format Meaning of data Local Reset Unit 1/0 The ISD Device includes the latch feature High Coding Level 1/0 The SI-RF sensor coding level is High/Unique Cascadable 1/0 The ISD Device includes the cascade feature Note: This will always be true for SI-RF models with ISD. Fault Tolerant Outputs 1/0 Indicates that the ISD Device includes the fault tolerant output feature where output faults cause a 20 minute off delay/fault delay Note: This will always be true for SI-RF models with ISD. Table 4: Individual Unit Data—Values Short Name Data Format Meaning of data Device Type of ISD Device Expected Code For SI-RF sensors with high or unique coding, displays the actuator code taught to the sensor Received Code Displays the actuator code detected by the SI-RF sensor Teach-ins Remaining number For SI-RF sensors with high and unique coding, displays the remaining number of teaches available Note: Low and already taught unique units display (0). Number of voltage errors number The number of voltage warnings received in the last 60 seconds (voltage is checked every second), a number between 0 and 60 Number of operations number The number of on/off cycles the sensor has experienced Output Switch-off time number The delay counter for certain output errors (0 = inactive, 20 to 1 = remaining minutes to device lockout state) Range Warning Count number For SI-RF Sensors, a count of the number of range warnings received in the last 60 minutes. The counter increments when at least half of the RFID read attempts in a minute had a range warning. Supply Voltage number The actual input voltage detected by the ISD sensor Internal Temperature number The internal temperature of the ISD Sensor (°C) Actuator Distance number The distance the actuator is from the SI-RF sensor. This value is displayed as a percentage of the range of the SI-RF sensor. Expected Company Name Banner's company code is 6 Received Company Name Banner's company code is 6 6.4 Contact Us Banner Engineering Corp. headquarters is located at: 24 www.bannerengineering.com - Tel: + 1 888 373 6767 SI-RF Non-Contact RF Safety Switch 9714 Tenth Avenue North Minneapolis, MN 55441, USA Phone: + 1 888 373 6767 For worldwide locations and local representatives, visit www.bannerengineering.com. 6.5 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. www.bannerengineering.com - Tel: + 1 888 373 6767 25
SI-RFA-P 价格&库存

很抱歉,暂时无法提供与“SI-RFA-P”相匹配的价格&库存,您可以联系我们找货

免费人工找货