IsoBlock C
Specification Sheet for Verivolt Galvanic-Isolated Module for
Sensor Isolation, Fuel-Cell and Battery Monitoring
OVERVIEW
The IsoBlock module has been designed to provide low-cost and high-quality isolated differential
voltage measurements along a chain of fuel-cells or batteries. Our innovative modular architecture
and isolation techniques allow users to connect multiple IsoBlock modules together serially, facilitating the monitoring of long fuel-cell or battery chains.
Each IsoBlock unit hosts four separate isolated channels, each of which can be connected to separate measurement sources while providing a range of functional coverage up to 30V. The input of
each specific IsoBlock channel has its own isolated reference, and can be configured to suit user
needs. All processed signals output from the IsoBlock unit are referenced in respect to the ground
channel of the user’s data acquisition system.
Verivolt designs its IsoBlock modules with consideration for user flexibility, exceptionally high
channel-density and low power consumption.
SPECIFICATION
Eletrical
Accuracy (of reading)
±0.2%
Bandwidth
(-3dB point)
DC – 100kHz
(custom up to 1MHz)
Integrated channel noise
(Referenced to output)
< 1 mV
Input-Output non-linearity
< 80 ppm
Differential input dynamic
range per channel
±2V, ±5V, ±10V, ±15V ±30V
Channel to channel
isolation
± 1800V Working Voltage
± 5000V Surge Voltage
Isolation voltage from
primary side to secondary side
± 1800V Working Voltage
± 5000V Surge Voltage
Gain temperature drift
±50 ppm/°C
Max total phase shift
at 60Hz
< 0.05°
Max Input delay
< 2.8 μs
Common mode rejection
The figure above indicates the input, output and power polarity
of the IsoBlock module.
The IsoBlock module is designed to mount on standard NS-35
or NS-32 DIN rails with minimal preparation, providing users
an indispensible monitoring utility with unparalleled flexibility.
8V to 28V
Output type
Differential pair
Output Offset Voltage
< ±750μV
Differential Input impedance
Output impedance
> 2 GΩ
50 Ω
MERCHANICAL
Mounting Type
DIN Rail
Connectivity (Connector
for power and signals)
Weight
The IsoBlock module is designed to isolate a bank of differential unipolar input signals, while selectively removing their highvoltage common mode. With four discrete channels per IsoBlock
module, the device features channel-to-channel isolation as well
as a channel-to-ground isolation, rated at 1800V. Each input’s
dynamic range is set to match one of seven standard values, or
may be customized to specification, upon request.
108 dB at DC 95 dB at 50kHz
Power Supply Voltage
Outer Dimensions
HARDWARE
DESCRIPTION
Spring Cage
DIN Rail Mounting the Sensor
Verivolt’s IsoBlock variable voltage monitoring module comes
pre-assembled with a housing allowing for users to quickly and
securely mount the device to industry-standard DIN rail guides.
The flexible clip on the reverse of the unit’s housing latches to
the parallel rails of the DIN, affording the IsoBlock exceptional
modularity and ease of deployment within integrated Systems.
4.3” x 3.4” x 2.4”
218 g (7.7 oz)
ENVIORNMENT
Operating temperature
– 25 to 70 °C
Storage temperature
– 40 to 80 °C
650 Washington St, San Francisco, CA 94111
(708) 374-8658
1
MERCHANICAL
DIMENSIONS
HARDWARE
CONFIGURATION
A. Connect ground of sensor to ground
of data acquisition (DAQ) system
A
Standards and Certifications
B. Securely connect external power
source to primary power unit, with respect to line polarity. For proper functioning the power supply should provide between 8V and 28V with at least
.5A of current.
B
C. 1) Securely of signal source to input
of module.
2) Connect the leads from the module
output terminals to the inputs of your
data acquisition unit.
C
DANGER
THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the
failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage.
2
ISOBLOCK C-4C (10V) 价格&库存
很抱歉,暂时无法提供与“ISOBLOCK C-4C (10V)”相匹配的价格&库存,您可以联系我们找货
免费人工找货