0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SDN5-24-480C

SDN5-24-480C

  • 厂商:

    SOLAHD(SolaHD)

  • 封装:

    -

  • 描述:

    SDN5-24-480C

  • 数据手册
  • 价格&库存
SDN5-24-480C 数据手册
Power Supplies SDN-C Performance DIN Rail Series High performance specifications and extensive international certifications ensure that the SolaHD SDN-C is suitable for the most extreme environments, including hazardous locations and off-shore applications. Features like wide operating temperature range, power boost capability, and adjustable output voltage ensure reliable operation in the harshest industrial environments. Parallel operation, extensive LED diagnostics, and universal AC or DC input voltage simplify installation and maintenance. For added reliability, the SDN-C power supplies can be used with the SolaHD Redundancy modules to provide redundant power supply operation. UL 60950 E137632 ULE61379 508 Listed E137632 E234790 IND. CONT. EQ.CUL/CSA-C22.2 No. 234-M90 E61379 EMC and Low Volt. IECEx Directive Certifications and Compliances * All Models Applications • • Industrial Automation • Process Control • Material Handling and Conveyors • Hazardous Locations • Marine Applications Listed, Ind. Control Equipment, E61379 UL 508 Listed UL 508, CSA C22.2 No. 107.1 IND. CONT. EQ. • E61379 UL 60950 E137632 CUL/CSA-C22.2 No. 234-M90 UL Recognized Component, ITE, E137632 - UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition • • Features • Extensive international hazardous location certifications, including Class I, Zone 2, ATEX, IECEx, ExEAC. Hazardous location temperature code (T-Code) rating of T4. • International off-shore certifications, including ABS and DNV-GL • PowerBoostTM enables short duration overload capability, to start loads with high inrush current • Three LEDs provide extensive diagnostics • Dual output terminals for convenience in wiring • DC OK relay to provide diagnostic information to a PLC, controller, or monitoring system • Universal AC and DC input voltages to accommodate global requirements • Wide operating temperature range accommodates both extreme hot and extreme cold environments • Active Power Factor Correction on most models • Parallel operation capability standard • Supports redundant power supply operation using optional SDN™ Redundancy modules • 5-year limited warranty UL Recognized Component, Class I, Div 2; UL 60950 E137632 I Zone 2; T4 E234790 Class CUL/CSA-C22.2 No. 234-M90 - Low Voltage Directive EMC and Low Volt. Directive - IEC/EN60950-1, 2nd Edition • RoHS Compliant Models SDN 5-24-100C, SDN 10-24-100C, SDN 16-12-100C, SDN 20-24-100C, SDN 40-24-100C, SDN 5-24-480C, SDN 10-24-480C, SDN 20-24-480CD • UL 60950 E137632 CUL/CSA-C22.2 No. 234-M90 UL Recognized Component, Haz. Loc., E234790 - UL60079-0/CSA E60079-0, UL 60079-15, CSA E60079-15 - Class I, Zone 2, AEx nA nC IIC, Ex nA nC IIC • ATEX Directive - EN60079-0, EN60079-7, EN60079-15 - II 3 G, Ex ec nC IIC Gc • IECEx Certified - IEC 60079-0, IEC 60079-7, IEC 60079-15 - Ex ec nC IIC Gc Models SDN 5-24-100C, SDN 10-24-100C, SDN 16-12-100C, SDN 20-24-100C, SDN 40-24-100C, SDN 5-24-480C, SDN 10-24-480C • • TR CU 012/2011 Safety of Equipment intended for Explosive Atmospheres Type Approval Models SDN 5-24-100C, SDN 10-24-100C, SDN 16-12-100C, SDN 20-24-100C, SDN 40-24-100C • Type Approved Models SDN 5-24-100C, SDN 10-24-100C, SDN 20-24-100C, SDN 40-24-100C * Refer to user manual for installation requirements when used in hazardous locations. 122 • Certified Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. © December 2018 Power Supplies Related Products Accessories • SDN-C Redundancy Modules • Chassis Mount Brackets • IP67 SCP-X Extreme Environment Series • SDU UPS The SolaHD Difference Multiple output connections for ease of wiring multiple devices Rugged metal housing Visual LED diagnostics show input and output status (see table below) DC OK Relay Terminals provide diagnostic information to a PLC or controller Single or parallel use selectable by user Adjustable output voltage Clearly labeled front panel No internal fan, no extra cooling required in any power level Multiple certifications for versatility in applications Automatically adjusts for global Input voltages Narrow width saves panel space LED Light Status Conditions Normal AC Power Loss AC Input Low No DC High Load Overload Hot Too Hot Input Green - Amber Green Green Green Green Green Output Green - Green - Amber Amber Green - Alarm - - - Red Amber Red Amber Amber Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. © December 2018 123 Power Supplies SDN-C Specifications (Single Phase) Description Catalog Number SDN 16-12-100C SDN 5-24-100C SDN 10-24-100C SDN 20-24-100C SDN 40-24-100C 100-250 Vdc (90-275 Vdc) 120-340 Vdc (108-375 Vdc) Input 100 - 240 Vac (85-264 Vac) Nominal AC Voltage (Range) 100-340 Vdc (90-375 Vdc) Nominal DC Voltage (range) 43 - 67 Hz Frequency Nominal Current 1 -Inrush current Efficiency (Losses 2) 1.77 – 0.9 A 1.65 - 0.55 A 3.2 - 1.0 A 6-3A 12 - 4 A Typ. 30.5 but < 33 Vdc, auto-recovery Overtemperature Protection LED Alarm and Output shutdown , auto-recovery Environmental Data Emissions Immunity General Protection/ Safety Temperature 6 EN61000-6-3, EN61000-6-4, Class B EN55011, EN61000-3-2 Class A, Class B EN 55032, EN 61326-1 Class B, EN 61000-3-3 EN 55024, EN 61000-6-1, EN 61000-6-2, EN 61326-1, SEMI F47 Protected against continuous short circuit, continuous overload, continuous open circuit. IEC 60950-1: Class I Earthed, Output is SELV (Safety Extra Low Voltage), Environmental Rating: Pollution Degree 2 IEC 60529 Ingress Protection Rating: IP20 Storage: -40°C to +85°C, Operation -40°C to +60°C full power, with linear derating to 75% power from +60°C to 70°C (Convection cooling). Operation up to 50% load with sideways or front-side-up mounting orientation. Humidity 5 to 95 % RH Non-condensing; IEC 60068-2-2, IEC 60068-2-3 Vibration 2.5g RMS, 10-2000 Hz (random); three axes for 20 minutes each - IEC 60068-2-6 Shock Altitude 10(g) RMS, three axes, 11mseconds for each axis - IEC 60068-2-27 0 to 6000 meters (0 to 20,000 feet) per MIL-STD-810F 1. Input current ratings are conservatively specified with low AC input, worst case efficiency and power factor. 2. Losses are heat dissipation in watts at full load, nominal AC input line. 3. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor. 4. All models are capable of paralleling. For redundant operation, please use external Redundancy module. Only the 40A uses Active paralleling scheme. Please refer to user manual for details. 5. Peak current is calculated at nominal voltage levels. 6. Contact tech support for operation at -40°C. 124 Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. © December 2018 Power Supplies SDN-C Specifications (Single Phase) continued Catalog Number Description SDN 16-12-100C SDN 5-24-100C SDN 10-24-100C SDN 20-24-100C SDN 40-24-100C Reliability MTBF Telcordia SR-332 Issue 2 Method 1 Case 3 @ 25°C >2,088,000 hours @ 115 Vac >1,800,000 hours @ 115 Vac > 550,000 hours @ 115 Vac >2,133,000 hours @ 230 Vac >2,100,000 hours @ 230 Vac >650,000 hours @ 230 Vac >800,000 hours @ 115 Vac >850,000 hours @ 230 Vac >550,000 hours @ 115 Vac >570,000 hours @ 230 Vac Telcordia SR-332 Issue 2 Method 1 Case 3 @ 40°C >1,112,000 hours @ 115 Vac >1,000,000 hours @ 115 Vac >300,000 hours @ 115 Vac >1,170,000 hours @ 230 Vac >1,100,000 hours @ 230 Vac >400,000 hours @ 230 Vac >500,000 hours @ 115 Vac >570,000 hours @ 230 Vac >360,000 hours @ 115 Vac >370,000 hours @ 230 Vac Installation Input Branch fuse or circuit breaker should be provided by customer. See manual for details. Fusing -Input Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. -Output Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. Mounting 13-10 AWG (3-6 mm2) solid/stranded conductors. Screw Torque: 4.4 lb-inch (50 N-cm). 16–10 AWG (1.5–6 mm ) solid or stranded conductors. Screw torque: 4.4-6.5 lb-inch (50-73 N-cm). 2 Input Connections 7,8 (Screw Type) 0.98 in (25 mm) Above & Below -Free Space 1.6 in (40 mm) 0.59in (15mm) 0.59 (15) Front Weight - lbs (kg) 0.98in (25mm) 0.39 in (10mm) Left & Right Dimensions - WxDxH in (mm) 7–6 AWG (10.6–13 mm2 ) solid/stranded conductors. Screw Torque: 15.6 lb-inch (176 N-cm) 16–10 AWG (1.5–6 mm2) for solid or stranded conductors. Screw torque: 4.4-6.5 lb-inch (50-73 N-cm). Output (dual output terminals) 4.85 × 2.36 × 4.36 (123.0 × 60.0 × 110.0) 4.85 × 1.97 × 4.36 (123.0 × 50.0 × 110.0) 4.85 × 2.36 × 4.36 (123.0 × 60.0 × 110.0) 4.85 x 3.42 x 4.98 (123.0 x 87.0 x 127.0) 4.85 x 7.09 x 4.81 (123.0 x 180.0 x 122.0) 1.76 (0.80) 1.3 (0.6) 1.7 (0.8) 3.0 (1.4) 6.0 (2.8) General Case Status Indicators Warranty Fully enclosed metal housing with fine ventilation grid to keep out small parts. IP20 touch proof Visual: 3 status LEDs (Input, Output, Alarm) Relay: N.O. contact rated 200mA/50 Vdc Signal Active when Vout > 18.5 Vdc +/-5% (Vout > 10.8 Vdc for SDN 16-12-100C) 5 Year Limited Warranty 7. Screw terminals. Use only one copper wire per terminal. Non-ratcheting torque driver recommended. 8. SDN 40-24-100C only — Provided with Signal Mode terminal block which includes the following features: DC OK, Ground signal, PS ON, I_share connection. Refer to Signals Manual for terminal connection details.. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. © December 2018 125 Power Supplies SDN-C Specifications (Three Phase) Description Catalog Number SDN 5-24-480C SDN 10-24-480C SDN 20-24-480CD SDN 40-24-480C Input 380 - 480 Vac (320 - 540 Vac), 3-phase Nominal AC Voltage (Range) Yes Two-phase input 1 600 Vdc (+/- 50 Vdc) Nominal DC Voltage (Range) 50/60 Hz Frequency Nominal Current 2 3 x 0.5 A Power Factor Correction 3 x 0.9A Typ. < 25 A -Inrush current max. Efficiency (Losses 3) 3 x 0.8 A > 85% (18 W) 3 x 1.6A Negligible 91% (24W) 93% (42 W) Meets EN61000-3-2 Class A 94% (78 W) Active Power Factor Correction > 0.92 Output 24 V (23.5 – 28.5 Vdc Adj.) Nominal Voltage 4 24.5 V ± 1% Initial Voltage Setting < ±2 % overall (combination Line, load, time and temperature related changes) -Tolerance -Ripple 5 PARD (Periodic and Random Deviation) Nominal Current (Rated Power) Parallel Operation 6 Turn On Time Holdup Time (Full load, 100 Vac Input @ T = +25°C) Voltage Fall Time 5 A (120 W) < 50 mVpp < 100 mVpp 100 mVpp max 200 mVpp max 10 A (240 W) 20 A (480 W) 40 A (960 W) Single or Parallel operation selectable via front switch. Active Paralleling. < 1 s after AC is applied to input at full resistive load ( Tamb=+25°C ). 20 Vdc PowerBoost™ < 35 V No damage, auto-recovery > 30.5 but < 33 Vdc, auto-recovery LED Alarm and Output shutdown , auto-recovery Environmental Data Emissions EN 61000-6-3, EN 55011 Class B, EN 55022 Class B, EN 61326-1, EN 61000-3-2, EN 61000-3-3 EN 61000-6-3, EN 55011 Class B, EN 55032 Class B, EN 61326-1, EN 61000-3-2, EN 61000-3-3 EN 55011 Class B, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3 Immunity EN 55024, EN 61326-1, EN 61000-6-1, EN 61000-6-2, SEMI F47 EN 55024, EN 61326-1, EN 61000-6-1, EN 61000-6-2, SEMI F47 EN 61000-4-2, EN 61000-4-4, EN 61000-4-5, SEMI F47 General Protection/ Safety Temperature 8 Protected against continuous short circuit, continuous overload, continuous open circuit. IEC 60950-1: Class I Earthed, Output is SELV (Safety Extra Low Voltage), Environmental Rating: Pollution Degree 2 IEC 60529 Ingress Protection Rating: IP20 Storage: -40°C to + 85°C, Operation -40°C to +60°C full power, with linear derating to 75% power from 60 to 70°C (Convection cooling, no forced air required). Operation up to 50% load permissible with sideways or front-side-up mounting orientation. Humidity 5 to 95 % RH Non-condensing, IEC 60068-2-2, IEC 60068-2-3 Vibration 2.5g RMS, 10-2000 Hz (random); three axes for 20 minutes each - IEC 60068-2-6 Shock Altitude 10g RMS, three axes, 11mseconds for each axis - IEC 60068-2-27 0 to 3000 meters (0 to 10,000 feet) 1. In the event of a phase loss, the power supply will continue to operate normally. However, the resulting lower rectified RMS voltage can cause excessive heat build up, which may eventually cause the unit to shut down if maximum operating temperature is exceeded. 2. Input current ratings are specified with low AC 3-phase input, line conditions, worst case efficiency values and power factor spikes. Input current at nominal AC 3-phase input will typically be half these values. 3. Losses are heat dissipation in watts at full load, nominal line. 4. 24-28 Vdc adjustable guaranteed at full load. 5. Ripple/noise is stated as typical values when measured with a 20 MHZ, bandwidth scope and 50 Ohm resistor 6. All models are capable of paralleling. For redundant operation, please use external Redundancy module. Only the 40A uses active paralleling scheme. Please refer to user manual for details. 7. SDN 20 and SDN 40 are capable of delivering 150% load for approximately 4s before the unit will go to HICCUP mode. SDN 5 and 10 will maintain minimum 4s to deliver 150% load then drops to almost zero Vout. The output voltage will immediately drop to almost zero when load rises above 150%. 8. Contact Tech Support for operation -40°C. 126 Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. © December 2018 Power Supplies SDN-C Specifications (Three Phase) Catalog Number Description SDN 5-24-480C SDN 10-24-480C SDN 20-24-480CD SDN 40-24-480C Reliability MTBF Telcordia SR-332 Issue 2 Method 1 Case 3 @ 25°C >1,100,000 hours @ 380 Vac >900,000 hours @ 480 Vac >1,400,000 hours @ 380 Vac >900,000 hours @ 480 Vac >630,000 hours @ 380 Vac >630,000 hours @ 480 Vac >600,000 hours @ 380 Vac >550,000 hours @ 480 Vac Telcordia SR-332 Issue 2 Method 1 Case 3 @ 40°C >600,000 hours @ 380 Vac >500,000 hours @ 480 Vac >910,000 hours @ 380 Vac >600,000 hours @ 480 Vac >460,000 hours @ 380 Vac >450,000 hours @ 480 Vac SDN 20-24-480CR >380,000 hours @ 380 Vac >360,000 hours @ 480 Vac Visual: 3 status LEDs (Input, Output, Alarm) Relay: N.O. contact rated 200mA/50 Vdc, Signal Active when Vout> 18.5 Vdc +/-5% Status Indicators Installation Input Branch fuse or circuit breaker should be provided by customer. See manual for details. Fusing -Input Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. -Output Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. Mounting 16-10 AWG (1.5-6 mm2) for solid conductors. Screw Torque: 4.4 lb-in (~ 50 N-cm). Input Connections 9,10 (Screw Type) Output 0.98 in (25 mm) Above & Below -Free Space 1.6 in (40 mm) 2.80 in (70mm) 4.85 x 3.42 x 4.98 (123.0 x 87.0 x 127.0) 4.85 x 7.09 x 4.66 (123.0 x 180.0 x 119.0) 2.7 (1.2) 5.3 (2.4) Left & Right 0.98in (25mm) Front 0.59 in. (15 mm) Dimensions - WxDxH in (mm) Weight - lbs (kg) 7–6 AWG (10.6–13 mm2 ) solid or stranded conductors. Screw Torque: 15.6 lb-inch (176 N-cm) 16-10 AWG (1.5-6 mm2) for solid conductors. Screw Torque: 7 lb-inch (~ 80 N-cm) 4.85 × 1.97 × 4.36 (123.0 × 50.0 × 110.0) 4.85 × 2.36 × 4.36 (123.0 × 60.0 × 110.0) 1.2 (0.5) 1.5 (0.7) General Case Status Indicators Warranty Fully enclosed metal housing with fine ventilation grid to keep out small parts. IP20 touch proof Visual: 3 status LEDs (Input, Output, Alarm) Relay: N.O. contact rated 200mA/50 Vdc, Signal Active when Vout> 18.5 Vdc +/-5% 5 Year Limited Warranty 9. Screw terminals. Use only one copper wire per terminal. Non-ratcheting torque driver recommended. 10. SDN 40-24-480C only: Output signaling terminal block features (Shut down, Power Good, Current Monitor, Current Balance, signal GND). Please refer to Signals Manual for details. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. © December 2018 127 Power Supplies SDN-C Series Dimensions 4.68 in. [118.8 mm] 4.85 in. [123.3 H mm] 5.51 in. [140.0 mm] W in. 1.97 [50.0 mm] Dimensions - inches (mm) Catalog Number 4.36 in. D [110.8 mm] Power Supply SDN5-24-100C H W D SDN 5-24-100C 4.85 (123.0) 1.97 (50.0) 4.36 (111.0) SDN 10-24-100C 4.85 (123.0) 2.36 (60.0) 4.36 (111.0) SDN 16-12-100C 4.85 (123.0) 2.36 (60.0) 4.36 (111.0) SDN 20-24-100C 4.85 (123.0) 3.42 (87.0) 4.98 (127.0) SDN 5-24-480C 4.85 (123.0) 1.97 (50.0) 4.36 (111.0) SDN 10-24-480C 4.85 (123.0) 2.36 (60.0) 4.36 (111.0) SDN 20-24-480CD 4.85 (123.0) 3.42 (87.0) 4.98 (127.0) 4.78 in. [121.6 mm] SDN 40-24-480C Dimensions SDN 40-24-100C Dimensions D W 4.81 in. [122.2 mm] H 4.85 in. [123.3 mm] PowerSupply Supply Power Power Supply Signal Connector D 7.09 in. [180.0 mm] SOLA H 5.51 in. (139.96 mm) W 5.35 in. [136.0 mm] D + 0.54 in (13.80 mm) D + 0.54 in (13.80 mm) Voltage adjustment potentiometer located on top of power supply Catalog Number Dimensions - inches (mm) H W D SDN 40-24-100C 4.85 (123.0) 7.09 (180.0) 4.81 (122.0) SDN 40-24-480C 4.85 (123.0) 7.09 (180.0) 4.66 (119.0) SDN 40-24-100C and SDN 40-24-480C output signaling terminal block features: Shut Down, Power Good, Current Monitor, Current Balance, GND, and active current sharing through I_SHARE connectors (See Signals Manual for connection information). 128 Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. © December 2018 Power Supplies SDN-C Series Mounting Panel Mount Brackets Installation SolaHD SDN-C power supplies are designed tothebe and reliably mounted to DIN rail. For applications requiring 1. Remove M3X6easily mm Phillips Screws, shoulder screw, plastic slide, spring C-Insert from the DIN Brackets. Power Supply Accessories mounting the power supply directly to the and panel, optional Panel Mount Adapter Brackets are available. SDN-PMBRK3 Panel DIN Mount Brackets Installation Manual Rail Mounting Power Supply Accessories Snap on the DIN rail: 7 83472 00651 C-Insert 3. Push downwards until stopped DIN Bracket Reta of th 3. Pus with Detachment from DIN00651 Rail: 9 7 83472 Shoulder screw P/N: A272-289 REV. 1 (07/16) ©2016 Appleton Grp LLC d/b/a Appleton Group All rights reserved. Specifications subject to change without notice. 4. Push at the lower front edge to lock P/N: A272-289 REV. 1 (07/16) ©2016 Appleton Grp LLC d/b/a Appleton Group All rights reserved. Specifications subject to change without notice. Plastic slide 5. Shake the unit slightly to ensure that the retainer hasCAUTION: locked 2. 2. M3X6 mm Phillips Screw 9 Risk of Electric Shock and Personal Injury Rem SDN-PMBRK3 Panel Mount Brackets Installation Manual Spring 1. Tilt unit slightly backwards. Put it onto the DIN rail 1. Retain and slide back the two DIN brackets to use as a guide for the installation of the panel mount brackets. CAUTION: Risk of Electric Shock and Personal Injury Alternative Panel Mount: Using the optional SDN-PMBRK3 accessory, the unit can be screw mounted to a panel. Ensure unit is disconnected from all power sources prior to replacing brackets. Ensure unit is disconnected from all power sources prior to replacing brackets. CHASSIS MOUNTING CHASSIS MOUNTING This set consists of two panel mount brackets, which replace the existing two DIN mounting brackets at the back of the unit. This set consists of two panel mount brackets, which replace the existing two DIN mounting brackets at the back of the unit. DIN Bracket FOR USE WITH: Panel Mounting FOR USE WITH: SDN 5-24-100C SDN 10-24-100C SDN 40-24-100C SDN 10-24-480C SDN 2X20RED SDN 5-24-100C SDN 10-24-100C SDN 40-24-100C SDN 10-24-480C SDN 2X20RED Panel mounting of SDN-C power supplies is simplified by using an optional Panel Mounting Bracket kit. Each kit comes with two brackets for modifying one power supply. Choose the appropriate bracket kit based on the power supply model in the tables below. Note that the Panel Mount bracket will add approximately 2-4mm in depth, compared to DIN rail mounting. Two M3x10 mm phillips screws Refer to the manual that comes with the bracket kit for detailed instructions on assemblyINCLUDED: and mounting. Two brackets INCLUDED: Two M3x8 mm phillips screws Two brackets Two lock washers SDN-PMBRK3 NOT INCLUDED: Four 8-32 x 1/2” screws for mounting unit to panel Four 8-32 flat washers Power Supply Two M3 lock washers NOT INCLUDED: 3. Push and slide the panel mount brackets on the top of DIN bracket and secure with M3X8 mm Phillips Screw and lock washer (use 7kgf torque). Panel Mou Bracket Dimensions - in. (mm) Panel Mount Bracket SDN 16-12-100C Dimensions in Inches (Millimeters) DIN Bracket 1.93 (49.0) SDN 5-24-100C Dimensions in Inches (Millimeters) SDN 10-24-100C 1.65 (41.9) 1.47 (37.3) SDN 20-24-100C SDN 40-24-100C 1.65 (41.9) Four 8-32 x 1/2” screws for mounting unit to panel Four 8-32 flat washers 0.60 (15.2) SDN 10-24-480C M3X8 mm Phillips Screw Back View SDN 20-24-480CD TopView View Top View 3D3D View 0.87 (22.1) Top View SDN-PMBRK2 Power Supply SDN 5-24-480C SDN 40-24-480C 3D View Dimensions - in. (mm) .70 (17.8) .43 (10.9) 1.59 (40.4) .23 (5.8) .51 (13.0) .18 .86 (4.6) (21.8) .60 (15.2) .60 (15.2) 1.30 (33.0) 1.80 (45.7) .35 (8.9) .08 (2.0) .23 (5.8) .40 (10.2) .25 (6.4) .26 (6.6) 2.16 (54.9) .52 (13.2) Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. © December 2018 .52 (13.2) 129
SDN5-24-480C 价格&库存

很抱歉,暂时无法提供与“SDN5-24-480C”相匹配的价格&库存,您可以联系我们找货

免费人工找货