110W Triple Output
Medical Grade
MINT3110 Family
FEATURES AND BENEFITS
Medical
2” x 4” x 1.3” Package
Approved to EN/CSA/IEC/UL60601-1
Suitable for 1U Applications
2 x MOPP Isolation
Class I and Class II Versions
Power Fail Signal
110W w/air, 80W Convection Cooled
Remote Sense (optional)
Universal Input 90-264Vac
3 Year Warranty
Efficiency 87% Typical
RoHS Compliant
MODEL SELECTION
Model Number
MINT3110A0508K01
MINT3110A1708K01
MINT3110A1908K01
Output Current***
w/200LFM air
Convection
Volts*
Ripple &
Noise***
Total Regulation
OVP Threshold
V1
5V
14.0A
10.0A
1.0% pk-pk
±2%
7.5V max.
V2
12V
6.0A
4.5A
1.0% pk-pk
±3%
115%-135%
V3
-12V
1.0A
1.0A
2.0% pk-pk
±10%
115%-135%
V1
5V
14.0A
10.0A
1.0% pk-pk
±2%
7.5V max.
V2
15V
4.5A
3.5A
1.0% pk-pk
±3%
115%-135%
V3
-15V
1.0A
1.0A
2.0% pk-pk
±10%
115%-135%
V1
5V
12.0A
8.0A
1.0% pk-pk
±2%
7.5V max.
V2
24V
4.0A
3.0A
1.0% pk-pk
±3%
115%-135%
V3
-24V
1.0A
1.0A
2.0% pk-pk
±10%
115%-135%
Notes:
1.
2.
3.
4.
* 5V output is adjustable with +/-5% range
** Total convection power is 80 Watts
*** Measured with noise probe directly across output terminals, and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. Ripple & Noise of V2 at
no
load is 2% maximum
MINT3110 Datasheet V0422
Copyright © 2022 SL Power Electronics Corp. All rights reserved.
Page 1
110W Triple Output
Medical Grade
MINT3110 Family
INPUT
OUTPUT
AC Input
100-240Vac, ±10%, 47-63Hz, 1Ø 120–370Vdc
Input Current
115Vac: 1.5A, 230Vac: 0.75A
Inrush Current
264Vac, cold start: will not exceed 45A
Input Fuses
F1, F2: 2.5A, 250Vac fuses provided on all models
Earth Leakage Current
很抱歉,暂时无法提供与“MINT3110A0508K01”相匹配的价格&库存,您可以联系我们找货