Cautions and Warnings
Please be noted that this spec is only for reference if you have projects
designed with the product number listed in. If you are looking for new
project design-in, please find BWVH Series specification/datasheet on
Chilisin website. Or you may find our sales contact for more information on
old part number at your convenience. Appreciated your attention and
understanding.
Note: Please be sure to request approval specifications that provide further details of the products.
Kindly note that the content of these specifications are subject to change or may be discontinued
without prior notice. This product may not be designed/used in medical or high risk applications
without Chilisin approval. Please contact our sales department before ordering.
Sealed Power Inductors – LVH Series
LVH Series
LVH series, an automatic assembly constructed power inductor, is
shielded with magnetic resin and suitable for portable DC-DC
converter applications.
Features
Applications
RoHS, Halogen Free and REACH Compliance
Shielded with magnetic resin
Low profile, miniature package size and wide inductance range.
Low DCR and high rated current.
Smart phone
DSC
Tablet PC and other portable devices
DC/DC converters
Product Identification
Shape and Dimensions
Recommended Pattern
Dimensions in mm
TYPE
A
B
C
D
H
I
J
LVH201B10H
2.0±0.25
1.6±0.25
1.02 Max
0.6
1.8
0.8
0.8
LVH252A10H
2.5±0.25
2.0±0.25
1.00 Max
0.8
2.2
0.85
0.8
LVH252A12
2.5±0.25
2.0±0.25
1.2±0.05
0.8
2.2
0.85
0.8
LVH252A12H
2.5±0.25
2.0±0.25
1.2±0.05
0.8
2.2
0.85
0.8
Sealed Power Inductors - LVH Series
– LVS201610 Series
Electrical Characteristics
Inductance
Tolerance
(uH)
(±%)
LVH201B10H-R24□-N
0.24
20, 30
LVH201B10H-R33□-N
0.33
20, 30
LVH201B10H-R47□-N
0.47
LVH201B10H-R56□-N
LVH201B10H-R68□-N
Test
RDC
Isat (mA)
Irms (mA)
(Ω) ±30%
Typ. (Max)
Typ. (Max)
1
0.048
3700(3300)
2500(2100)
1
0.048
3400(3000)
2500(2100)
20, 30
1
0.072
2900(2600)
2100(1800)
0.56
20, 30
1
0.072
2700(2400)
2100(1800)
0.68
20, 30
1
0.092
2500(2200)
1800(1500)
LVH201B10H-1R0□-N
1.0
20, 30
1
0.110
2200(2000)
1500(1200)
LVH201B10H-2R2□-N
2.2
20, 30
1
0.205
1400(1200)
1150(970)
LVH201B10H-3R3□-N
3.3
20, 30
1
0.380
1050(940)
900(800)
LVH201B10H-4R7□-N
4.7
20, 30
1
0.520
900(800)
800(680)
LVH201B10H-100□-N
10
20, 30
1
1.100
620(550)
450(380)
Part Number
Frequency
(MHz)
Note: When ordering, please specify tolerance code. Tolerance: M=±20% , T =±30%
Operating temperature range-55℃~125℃(Including self - temperature rise)
Isat for Inductance drop 30% from its value without current
Irms for a 40℃ temperature rise from 25℃ ambient with current
Measure Equipment:
L:Agilent HP4287A+Agilent HP16197A, 1MHz 200mV
RDC:DIGITAL MILLINHM METER CHROMA 16502, or equivalent
Isat & Irms:Agilent HP4284A
Test Instruments:HP4284A Material/Impedance Analyzer
Inductance vs. DC Current
Tem perature Change vs. DC Current
11
80
3R3
10
70
9
100
60
8
△ T( ℃ )
7
L(uH)
2R2
100
6
5
4R7
4
3R3
3
1R0
R68
R24
R47
4R7
50
40
30
20
2R2
2
1R0
1
10
R68
R47
R24
0
0
0
0.5
1
1.5
2
2.5
3
3.5
DC Current(A)
4
4.5
5
5.5
0
0.5
1
1.5
2
2.5
DC Current(A)
Please be sure to request approval specifications that provide further details of the products. Kindly note that the content of these
specifications are subject to change or may be discontinued without prior notice. This product may not be designed/used in
medical or high risk applications without Chilisin approval. Please contact our sales department before ordering.
3
3.5
4
Sealed Power Inductors - LVH Series
– LVS201610 Series
Electrical Characteristics
Inductance
Tolerance
(uH)
(±%)
LVH252A10H-R24□-N
0.24
20, 30
LVH252A10H-R47□-N
0.47
20, 30
LVH252A10H-R68□-N
0.68
LVH252A10H-1R0□-N
LVH252A10H-2R2□-N
Test
RDC
Isat (mA)
Irms (mA)
(Ω) ±30%
Typ. (Max)
Typ. (Max)
1
0.030
4700(4200)
3600(3000)
1
0.043
3300(3000)
2700(2300)
20, 30
1
0.062
2800(2500)
2300(1900)
1.0
20, 30
1
0.080
2300(2100)
1900(1600)
2.2
20, 30
1
0.135
1600(1400)
1400(1100)
LVH252A10H-4R7□-N
4.7
20, 30
1
0.330
1000(900)
850(720)
LVH252A10H-100□-N
10
20, 30
1
0.670
720(640)
580(490)
Part Number
Frequency
(MHz)
Note: When ordering, please specify tolerance code. Tolerance: M=±20% , T =±30%
Operating temperature range-55℃~125℃(Including self - temperature rise)
Isat for Inductance drop 30% from its value without current
Irms for a 40℃ temperature rise from 25℃ ambient with current
Measure Equipment:
L:Agilent HP4287A+Agilent HP16197A, 1MHz 200mV
RDC:DIGITAL MILLINHM METER CHROMA 16502, or equivalent
Isat & Irms:Agilent HP4284A
Test Instruments:HP4284A Material/Impedance Analyzer
Inductance vs. DC Current
Tem perature Change vs. DC Current
5.5
70
1R0
5.0
4.5
2R2
R24
R47
4R7
4.0
50
△ T(℃ )
3.5
L(uH)
4R7
60
3.0
2.5
2.0
40
30
2R2
20
1.5
1R0
1.0
10
R47
0.5
R24
0
0.0
0
0.5
1
1.5
2
2.5
3
3.5
DC Current(A)
4
4.5
5
5.5
6
0
0.5
1
1.5
2
2.5
3
DC Current(A)
Please be sure to request approval specifications that provide further details of the products. Kindly note that the content of these
specifications are subject to change or may be discontinued without prior notice. This product may not be designed/used in
medical or high risk applications without Chilisin approval. Please contact our sales department before ordering.
3.5
4
4.5
5
Sealed Power Inductors - LVH Series
– LVS201610 Series
Electrical Characteristics
Inductance
Tolerance
(uH)
(±%)
LVH252A12-R24□-N
0.24
20, 30
LVH252A12-R33□-N
0.33
20, 30
LVH252A12-R47□-N
0.47
LVH252A12-R50□-N
LVH252A12-R68□-N
Test
RDC
Isat (mA)
Irms (mA)
(Ω) ±30%
Typ. (Max)
Typ. (Max)
1
0.021
4700(4200)
3800(3200)
E
1
0.027
4200(3700)
3000(2500)
G
20, 30
1
0.027
3600(3400)
3000(2500)
J
0.50
20, 30
1
0.027
3600(3400)
3000(2500)
D
0.68
20, 30
1
0.036
2900(2600)
2800(2300)
H
LVH252A12-1R0□-N
1.0
20, 30
1
0.037
2700(2450)
2600(2200)
A
LVH252A12-1R5□-N
1.5
20, 30
1
0.075
2200(1900)
1900(1600)
I
LVH252A12-2R2□-N
2.2
20, 30
1
0.080
1900(1800)
1800(1500)
B
LVH252A12-4R7□-N
4.7
20, 30
1
0.195
1200(1000)
1100(930)
C
LVH252A12-100□-N
10
20, 30
1
0.400
900(800)
800(680)
F
LVH252A12-470□-N
47
20, 30
1
1.700
390(350)
340i(300)
K
Part Number
Frequency
(MHz)
Marking
Note: When ordering, please specify tolerance code. Tolerance: M=±20% , T =±30%
Operating temperature range-55℃~125℃(Including self - temperature rise)
Isat for Inductance drop 30% from its value without current
Irms for a 40℃ temperature rise from 25℃ ambient with current
Measure Equipment:
L:Agilent HP4287A+Agilent HP16197A, 1MHz 200mV
RDC:DIGITAL MILLINHM METER CHROMA 16502, or equivalent
Isat & Irms:Agilent HP4284A
Test Instruments:HP4284A Material/Impedance Analyzer
Inductance vs. DC Current
Tem perature Change vs. DC Current
11
80
10
2R2
70
100
9
8
1R0
△ T(℃ )
7
L(uH)
R24
60
100
6
5
4
R68 R50
1R5
4R7
4R7
3
50
40
30
20
2
2R2
1R5 1R0
1
R68
10
R50
R24
0
0
0
0.5
1
1.5
2
2.5
3
3.5
DC Current(A)
4
4.5
5
5.5
6
0
0.5
1
1.5
2
2.5
3
DC Current(A)
Please be sure to request approval specifications that provide further details of the products. Kindly note that the content of these
specifications are subject to change or may be discontinued without prior notice. This product may not be designed/used in
medical or high risk applications without Chilisin approval. Please contact our sales department before ordering.
3.5
4
4.5
5
Sealed Power Inductors - LVH Series
– LVS201610 Series
Electrical Characteristics
Inductance
Tolerance
(uH)
(±%)
LVH252A12H-R47□-N
0.47
20, 30
LVH252A12H-R68□-N
0.68
20, 30
LVH252A12H-1R0□-N
1.0
LVH252A12H-1R5□-N
LVH252A12H-2R2□-N
Test
RDC
Isat (mA)
Irms (mA)
(Ω) ±30%
Typ. (Max)
Typ. (Max)
1
0.031
4100(3700)
3100(2600)
1
0.031
3100(2900)
3100(2600)
20, 30
1
0.049
3200(3000)
3000(2500)
1.5
20, 30
1
0.088
2300(2100)
2200(1800)
2.2
20, 30
1
0.099
2200(2000)
2000(1700)
LVH252A12H-3R3□-N
3.3
20, 30
1
0.190
1400(1200)
1200(1000)
LVH252A12H-4R7□-N
4.7
20, 30
1
0.235
1300(1100)
1100(930)
LVH252A12H-100□-N
10
20, 30
1
0.510
920(820)
800(680)
Part Number
Frequency
(MHz)
Note: When ordering, please specify tolerance code. Tolerance: M=±20% , T =±30%
Operating temperature range-55℃~125℃(Including self - temperature rise)
Isat for Inductance drop 30% from its value without current
Irms for a 40℃ temperature rise from 25℃ ambient with current
Measure Equipment:
L:Agilent HP4287A+Agilent HP16197A, 1MHz 200mV
RDC:DIGITAL MILLINHM METER CHROMA 16502, or equivalent
Isat & Irms:Agilent HP4284A
Test Instruments:HP4284A Material/Impedance Analyzer
Inductance vs. DC Current
Tem perature Change vs. DC Current
10.0
80
9.0
70
1R0
8.0
100
R47
60
220 4R7
6.0
△ T( ℃ )
L(uH)
7.0
5.0
4.0
4R7
3.0
3R3
1R5
40
30
20
2R2
2.0
2R2
3R3
50
1R5
1R0
1.0
10
R47
0.0
0
0
0.5
1
1.5
2
2.5
3
DC Current(A)
3.5
4
4.5
5
0
0.5
1
1.5
2
2.5
3
DC Current(A)
Please be sure to request approval specifications that provide further details of the products. Kindly note that the content of these
specifications are subject to change or may be discontinued without prior notice. This product may not be designed/used in
medical or high risk applications without Chilisin approval. Please contact our sales department before ordering.
3.5
4
4.5
5
Sealed Power Inductors - LVH Series
Packaging Specifications
Tape Dimensions
Reel Dimensions
Dimensions in mm
Tape Dimensions
TYPE
Reel Dimensions
Quantity
A0
B0
K0
D
E
F
W
P
P0
P2
A
B
C
D
E
PCS / Reel
LVH201B10H
1.90
2.20
1.15
1.55
1.75
3.5
8.1
4
4
2
180
60
13
14.4
8.4
2000
LVH252A10H
2.40
2.70
1.15
1.55
1.75
3.5
8.1
4
4
2
180
60
13
14.4
8.4
2000
LVH252A12H
2.40
2.70
1.35
1.55
1.75
3.5
8.1
4
4
2
180
60
13
14.4
8.4
2000
LVH252A12
2.40
2.70
1.35
1.55
1.75
3.5
8.1
4
4
2
180
60
13
14.4
8.4
2000