Catalytic Flammable Gas Sensor
(Model: MC227D)
User’s Manual
Version: 1.0
Valid from: 2022-1-20
Zhengzhou Winsen Electronics Technology Co., Ltd
Statement
This manual copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without the
written permission, any part of this manual shall not be copied, translated, stored in database or
retrieval system, also can’t spread through electronic, copying, record ways.
Thanks for purchasing our product. In order to let customers use it better and reduce the faults
caused by misuse, please read the manual carefully and operate it correctly in accordance with the
instructions. If users disobey the terms or remove, disassemble, change the components inside of
the sensor, we shall not be responsible for the loss.
The specific such as color, appearance, sizes …etc., please in kind prevail.
We are devoting ourselves to products development and technical innovation, so we reserve the
right to improve the products without notice. Please confirm it is the valid version before using this
manual. At the same time, users’ comments on optimized using way are welcome.
Please keep the manual properly, in order to get help if you have questions during the usage in the
future.
Zhengzhou Winsen Electronics Technology CO., LTD
Zhengzhou Winsen Electronics Technology Co., Ltd
www.winsen-sensor.com
MC227D Catalytic Flammable Gas Sensor
Product
MC227D adopts catalytic combustion principle, and its two arms
of electric bridge consists of a test element and a compensate
element. The resistance of the test element rises once it meets
the combustible gases, in the same time, the output voltage of
the bridge changes and the voltage variation rises in direct
proportion to the gas concentration. The compensate element,
as a conference, has the function of compensating temperature
and humidity.
Features
Bridge output voltage in linear
Fast response
Good repeatability and selectivity
Good stability and reliability
Resist H2S poisoning & organosilicone.
Main Applications
It is widely used in public places (not industrial occasion) to detect the
concentration or leakage of combustible gases such as natural gas, LPG,
coal gas.
Fig1. Sensor Structure
Parameters:
Model
MC227D
Sensor Type
Catalytic Type
Standard Encapsulation
Plastic base & metal cap
Working voltage(V)
2.5±0.1
Working current(mA)
150±10
Sensitivity
20%LEL CH4
12~35
(mV)
20%LEL C3H8
10~30
Linearity
≤5%
Measuring range(%LEL)
0~100
Response Time (90%)
≤10s
Recovery Time (90%)
≤30s
Working Environment
-40~+70℃