0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CR6211-150-20

CR6211-150-20

  • 厂商:

    CR

  • 封装:

    -

  • 描述:

    TRANSDCR AC 0-5 VDC OUT 1PHASE

  • 详情介绍
  • 数据手册
  • 价格&库存
CR6211-150-20 数据手册
AC Power Transducer DIN RAIL / PANEL MOUNT, ACTIVE / REACTIVE The CR6200 Series, Power Transducers and Transmitters are designed to provide a controlled output that is proportional to the average power. These devices are specifically targeted to provide an efficient solution to most power sensing needs. Units are designed for operation in systems with sinusoidal voltage and current wave forms. Applications Energy Management Motor Efficiency Multi-point power sensing Remote power sensing over long distances CR6210 CR6211 CR6220 CR6221 Features 35mm DIN Rail or Panel Mount Ranges available for any power sensing need Active and Reactive power sensing 0 - 5 VDC and 4 - 20 mADC outputs Connection diagram printed on case Transducers C Regulatory Agencies Recognized to meet UL 61010B-1 Constructed to meet CAN/CSA-C22.2, No. 61010-1-2004 Meets requirement of IEC 61010-1 and BS EN 61010-1 CR6230 CR6231 CR6240 CR6241 E199795 CR6250 CR6251 CR6260 CR6261 V CR Magnetics has a wide selection of Current and Potential Transformers to extend the range of any part. The Professional Energy Monitoring Company M N TI ISO 9001:2008 Quality Management System I - ACTIVE POWER - REACTIVE POWER POWER TRANSDUCERS CAN BE ORDERED TO MEASURE ACTIVE OR REACTIVE POWER 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com 52 E-mail: sales@crmagnetics.com AC Power Transducer DIN RAIL / PANEL MOUNT, ACTIVE / REACTIVE Add suffix for input range - PART NUMBERS - CR6210 CR6211 CR6220 CR6221 CR6230 CR6231 CR6240 CR6241 CR6250 CR6251 CR6260 CR6261 - 1 Phase, Active Power with 0 - 5 VDC Output 1 Phase, Reactive Power with 0 - 5 VDC Output 1 Phase, Active Power with 4 - 20 mADC Output 1 Phase, Reactive Power with 4 - 20 mADC Output 2-Phase, 3-Wire, Active Power with 0 - 5 VDC Output 2-Phase, 3-Wire, Reactive Power with 0 - 5 VDC Output 2-Phase, 3-Wire, Active Power with 4 - 20 mADC Output 2-Phase, 3-Wire, Reactive Power with 4 - 20 mADC Output 3-Phase, 4-Wire, Active Power with 0 - 5 VDC Output 3-Phase, 4-Wire, Reactive Power with 0 - 5 VDC Output 3-Phase, 4-Wire, Active Power with 4 - 20 mADC Output 3-Phase, 4-Wire, Reactive Power with 4 - 20 mADC Output SPECIFICATIONS [26.6] 1.05 Custom ranges available * not UL recognized 5 25 - 0-5 AAC 0-25 AAC CR Magnetics has a wide selection of current and potential transformers to extend the range of any part. Cleaning:................. Water-dampened cloth Relative Humidity:... 5% to 95%, Non-Condensing Supply Current: CR6210:......................Typical 35mA Max 45mA CR6220: Typical 75mA Max 110mA CR6230:......................Typical 50mA Max 70mA CR6240: Typical 75mA Max 110mA CR6250:......................Typical 50mA Max 70mA CR6260: Typical 75mA Max 120mA Torque Specs.:.............3.0 inch lbs. (0.4Nm) Weight:.........................0.5 lbs. DIN RAIL MOUNTING CLIP [25] .98 [62] 2.44 End View [31] 1.22 [6.6] .26 [6.6] .26 [73.1][83.3] 2.88 3.28 [64] 2.52 [3.3] .13 Optional Mounting [35] 1.38 [13.5] .53 [76.7] 3.02 [5.6] .22 TYP Top View 0-150 VAC 0-250 VAC 0-500 VAC * - [64] [76.7] 2.52 3.02 [5.6] .22 TYP [6.6] .260 [62] 2.44 [30.8] 1.21 [19.8] [19.8] .78 .78 [76.7] [64.2] 3.02 2.53 [28.3] 1.12 [88.7] 3.49 CR6210 CR6211 CR6220 CR6221 CR6230 CR6231 CR6240 CR6241 CR6250 CR6251 CR6260 CR6261 [36.6] 1.44 OUTLINE DRAWING NOTE: The building installation must have a switch or circuit-breaker that is in close proximity and within easy reach of the operator. The switch or circuit breaker shall be marked as the disconnecting device for the equipment. The Professional Energy Monitoring Company M N TI ISO 9001:2008 Quality Management System 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com 53 E-mail: sales@crmagnetics.com C Transducers Basic Accuracy:......................... 0.5% Linearity:................................... 10% to 100% FS Thermal Drift:............................ 500 PPM/°C Operating Temperature:............ 0°C to +60°C Installation Category:................. CAT II Vibration Tested To:................... IEC 60068-2-6,1995 Pollution Degree:........................2 Response Time: ....................... 250 ms max. 0-90% FS Supply Voltage:......................... 24 VDC +/- 10% MTBF:.......................................Greater than 100 K hours Frequency Range:....................50 Hz - 400 Hz, sine wave Insulation Voltage:.................... 2500 VDC Altitude:.................................... 2000 meter max.Output Load:........................................ 4-20 mADC -0 to 300 Ω 0-5 VDC - 2K Ω or Greater 150 250 500 AC Power Transducer DIN RAIL / PANEL MOUNT, AVERAGE SENSING N L1 N L1 1 2 3 4 7 6 5 + - - + 1 2 3 4 OUTPUT 1 9 8 9 8 OUTPUT 1 7 6 - + 5 SUPPLY Supply LOAD LOAD CR6210 CR6211 Single element, 0 - 5 VDC Output CR6220 CR6221 Single element, 4 - 20 mADC Output N N 1 2 3 4 L1 1 2 3 4 9 8 7 6 5 OUTPUT 1 + - OUTPUT 1 C L1 L2 SUPPLY CR6220 CR6221 Single element, 4 - 20 mADC Output with external voltage transformers L3 1 2 1 OUTPUT 1 8 7 + - 6 5 L3 L1 L2 9 3 4 2 9 3 4 8 7 6 + - OUTPUT 1 + - 5 SUPPLY LOAD SUPPLY LOAD CR6230 CR6231 2 element - 3 Wire, 0 - 5 VDC Output CR6240 CR6241 2 element - 3 Wire, 4 - 20 mADC output L1 L3 L2 L3 L2 + 1 1 2 3 4 OUTPUT 1 9 8 7 6 5 2 9 3 4 8 7 - + OUTPUT 1 + - 6 5 SUPPLY SUPPLY LOAD LOAD CR6230 CR6231 2 element - 3 Wire, 0 - 5 VDC Output shown with external voltage and current transformers CR6240 CR6241 2 element - 3 Wire, 4 - 20 mADC Output shown with external current transformer L1 L1 L2 - + - LOAD CR6210 CR6211 Single element, 0 - 5 VDC Output with external voltage transformers L1 + 9 8 7 6 5 SUPPLY LOAD Transducers L1 L3 L2 L3 N N 1 2 3 4 9 8 7 6 5 1 2 3 4 OUTPUT 1 + SUPPLY + 9 8 7 6 5 OUTPUT 1 + - SUPPLY LOAD LOAD CR6250 CR6251 3 element - 4 Wire, 0 - 5 VDC Output shown with external voltage and current transformers CR6260 CR6261 3 element - 4 Wire, 4 - 20 mADC Output shown with external current transformers CONNECTION DIAGRAMS The Professional Energy Monitoring Company M N TI ISO 9001:2008 Quality Management System 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com 54 E-mail: sales@crmagnetics.com
CR6211-150-20
物料型号:CR6200系列包括CR6210、CR6211、CR6220、CR6221、CR6230、CR6231、CR6240、CR6241、CR6250、CR6251、CR6260和CR6261。

器件简介:这些功率变送器和变送器旨在提供与平均功率成比例的控制输出,适用于多种功率传感需求。

引脚分配:文档中未明确提供引脚分配信息,但提供了连接图,显示了如何将设备连接到外部电压和电流变换器。

参数特性:包括基本精度0.5%,线性度10%至100% FS,热漂移500 PPM/°C,工作温度0°C至+60°C,响应时间最大250毫秒。

功能详解:CR6200系列可以测量有功和无功功率,提供0-5 VDC和4-20 mA DC输出,支持35mm DIN导轨或面板安装。

应用信息:适用于能源管理、电机效率、多点功率传感和远程功率传感。

封装信息:文档提供了DIN导轨安装夹的端视图和顶视图,以及外形图。
CR6211-150-20 价格&库存

很抱歉,暂时无法提供与“CR6211-150-20”相匹配的价格&库存,您可以联系我们找货

免费人工找货