0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EB-CC-CAT5-M4

EB-CC-CAT5-M4

  • 厂商:

    REDLIONCONTROLS(美国红狮)

  • 封装:

    -

  • 描述:

    Plug Modular Connector 8p8c (RJ45, Ethernet) Position

  • 数据手册
  • 价格&库存
EB-CC-CAT5-M4 数据手册
8-port IP67 Ethernet Real-Time Switch & Accessories Installation and Maintenance Manual January 2014 This manual applies to the following products: EB-GT-8ES-# EB-CP-RJ45-F# EB-CC-CAT5-M# EB-CC-PS-F# EB-CC-CAP-L# (IP67 Industrial Ethernet Switch) (IP67 RJ45 to RJ45 Passthru Bulkhead Connector) (IP67 Field Installable RJ45 Connector) (IP67 Field Installable Power Connector) (IP67 Protective Cap with Tether) 1 IP67 Switch Manual CHANGE HISTORY Version Date Description © 2014. Red Lion Controls. All Rights Reserved. 2 IP67 Switch Manual TABLE OF CONTENTS INSTALLATION AND HAZARDOUS AREA WARNINGS ............................................................................................... 5 AVERTISSEMENTS POUR INSTALLATION ET POUR ENDROITS DANGEREUX ..................................................... 5 1 General Information ............................................................................................................................................6 1.1 Overview ................................................................................................................................................................. 6 1.2 Operation ................................................................................................................................................................ 6 1.3 Performance Specs ................................................................................................................................................. 6 1.4 Standards and Safety .............................................................................................................................................. 6 2 LED Indicators .....................................................................................................................................................7 2.1 Overview ................................................................................................................................................................. 7 2.2 Power LED ............................................................................................................................................................... 7 2.3 ACT / LNK LEDs ........................................................................................................................................................ 7 2.4 10 / 100 LEDs........................................................................................................................................................... 7 3 Dimensions and Installation ................................................................................................................................8 3.1 Overview ................................................................................................................................................................. 8 4 Power Wiring .................................................................................................................................................... 10 4.1 Overview ............................................................................................................................................................... 10 4.2 Connector Assembly ............................................................................................................................................. 10 5 Ethernet Wiring................................................................................................................................................. 11 5.1 Overview ............................................................................................................................................................... 11 TYPICAL INDUSTRIAL ETHERNET SWITCH INSTALLATION ..................................................................... 11 5.2 Ethernet RJ45 Wiring Guidelines .......................................................................................................................... 11 ETHERNET CONNECTOR............................................................................................................................................ 12 ETHERNET CONNECTOR............................................................................................................................................ 12 5.3 Field Installable RJ45 Connector ........................................................................................................................... 12 5.4 Bulkhead Connector.............................................................................................................................................. 13 6 Switching Features ............................................................................................................................................ 14 6.1 Switching Features ................................................................................................................................................ 14 7 Technical Specifications ..................................................................................................................................... 16 8 Service Information ........................................................................................................................................... 18 8.1 Service Information ............................................................................................................................................... 18 8.2 Product Support .................................................................................................................................................... 18 © 2014. Red Lion Controls. All Rights Reserved. 3 IP67 Switch Manual Protected Technology Policy Red Lion protects your investment in Red Lion systems with long-term planned technology and our unique Protected Technology Policy. We will continue to support the specified capabilities of standard Red Lion products for at least five years. We plan each product improvement and new feature to be upward compatible with existing designs and installations. Our goals are to make each new software release bring new power to your Red Lion systems and have every existing feature, applications program and data file continue to work. We protect your investment even further with a liberal five-year trade-in policy. Exchange standard products for upgraded versions of the same product to take advantage of new features and performance improvements at any time for five years. A prorated trade-in allowance will be given for your existing equipment. Red Lion protects your long-term productivity with state-of-the-art planned technology and continued support. Statement of Limited Warranty Red Lion Controls, manufacturer of Red Lion products, warrants to Buyer that products, except software, manufactured by Red Lion will be free from defects in material and workmanship. Red Lion' obligation under this warranty will be limited to repairing or replacing, at Red Lion' option, the defective parts within one year of the date of installation, or within 18 months of the date of shipment from the point of manufacture, whichever is sooner. Products may be returned by Buyer only after permission has been obtained from Red Lion. Buyer will prepay all freight charges to return any products to the repair facility designated by Red Lion. This limited warranty does not cover losses or damages which occur in shipment to or from Buyer or due to improper installation, maintenance, misuse, neglect or any cause other than ordinary commercial or industrial applications. In particular, Red Lion makes no warranties whatsoever with respect to implied warranties of merchantability or fitness for any particular purpose. All such warranties are hereby expressly disclaimed. No oral or written information or advice given by Red Lion or Red Lion’s representative shall create a warranty or in any way increase the scope of this warranty. This limited warranty is in lieu of all other warranties whether oral or written, expressed or implied. Red Lion's liability shall not exceed the price of the individual units, which are the basis of the claim. In no event shall Red Lion be liable for any loss of profits, loss of use of facilities or equipment, or other indirect, incidental or consequential damages. © 2014. Red Lion Controls. All Rights Reserved. 4 IP67 Switch Manual INSTALLATION AND HAZARDOUS AREA WARNINGS These products should not be used to replace proper safety interlocking. No software-based device (or any other solid-state device) should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety. In particular, Red Lion disclaims any responsibility for damages, either direct or consequential, that result from the use of this equipment in any application. All power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods and in accordance with the authority having jurisdiction. WARNING (EXPLOSION HAZARD) - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1, DIVISION 2. WARNING (EXPLOSION HAZARD) - WHEN IN HAZARDOUS LOCATIONS, DISCONNECT POWER BEFORE REPLACING OR WIRING UNITS. WARNING (EXPLOSION HAZARD) - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS. AVERTISSEMENTS POUR INSTALLATION ET POUR ENDROITS DANGEREUX Ces produits ne doivent pas être utilisés pour remplacer le verrouillage de sécurité approprié. Aucun dispositif basé sur un logiciel (ou tout autre dispositif à l'état solide) devraient jamais être conçus pour être responsable de l'entretien de l'équipement consécutifs ou la sécurité du personnel. En particulier, Red Lion décline toute responsabilité pour les dommages, directs ou indirects, résultant de l'utilisation de cet équipement dans n'importe quelle application. Tout courant, câblage entrée et sortie (I / O) doit être conforme aux méthodes de câblage à la Classe I, Division 2 et conformément à l'autorité compétente. AVERTISSEMENT (RISQUE D’EXPLOSION) - LA SUBSTITUTION DE TOUT COMPOSANT PEUT NUIRE À LA CONFORMITÉ DE CLASSE I, DIVISION 2. AVERTISSEMENT (RISQUE D’EXPLOSION) - LORSQUE DANS DES ENDROITS DANGEREUX, DÉBRANCHEZ LE CORDON D'ALIMENTATION AVANT DE REMPLACER OU DE BRANCHER LES MODULES. AVERTISSEMENT (RISQUE D’EXPLOSION) - NE DÉBRANCHEZ PAS L'ÉQUIPEMENT À MOINS QUE L'ALIMENTATION À ÉTÉ COUPÉ OU QUE L’ENVIRONNEMENT EST CONNU POUR ÊTRE NON DANGEREUX. FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna; Increase the separation between the equipment and receiver; Connect the equipment into an outlet on a circuit different from that to which the receiver is connected; Consult the dealer or an experienced radio/TV technician for help. Copyright & Trademarks: Copyright  2014 Sixnet, Inc. All Rights Reserved. Note: All information in this document is subject to change without notice. © 2014. Red Lion Controls. All Rights Reserved. 5 IP67 Switch Manual 1 General Information 1.1 Overview This manual will help you install and maintain the IP67 Industrial Ethernet Switch and accessories. This unmanaged Switch is extremely easy to install and operate because little or no user configuration is required. Once the Ethernet connections are made and the unit is powered up it will immediately begin to operate. 1.2 Operation Unlike an Ethernet hub that broadcasts all messages out all ports, the IP67 Industrial Ethernet Switch will intelligently route Ethernet messages only out the appropriate port. The major benefits of this are increased bandwidth and speed, reduction or elimination of message collisions, and deterministic performance when tied with real-time systems. The IP67 Industrial Ethernet Switch supports both 10BaseT (10 Mbps) and 100BaseTx (100 Mbps) on its RJ45 ports. Each of these ports will independently auto-sense the speed, allowing you to interface to regular or fast Ethernet devices. Refer to Section 6 for more information on Industrial Ethernet Switch operation and features. 1.3 Performance Specs These general specifications apply to the IP67 Industrial Ethernet Switch. Refer to Section 7 for complete technical specifications. Ports 10/100BaseT(x) (Shielded RJ45) Required Voltage 10 - 30 VDC (-1) ; +/-16-40 VDC (-1EP) Ethernet Standards IEEE 802.3 (10BaseT), 802.3u (100BaseTX), 802.3x (Full Duplex) Ethernet Protocols All standard IEEE 802.3 protocols supported Speed Per Port RJ45: 10 Mbps (half duplex) or 200 Mbps (full duplex) Ethernet Isolation 1500 Volts RMS (for 1 minute) Operating Temp. -40 to 70 C (-1) ; -40 TO 60C (-1EP) Humidity 5 to 100% RH Vibration IEC 68-2-6 or better (completely potted design for max. resistance) 1.4 Standards and Safety The IP67 Industrial Ethernet Switch meets the following standards: Electrical safety - UL 508, CSA C22/14; EN61010-1 (IEC1010) EMI emissions - FCC part 15, ICES 003, EN55022; Class B EMC immunity – EN61326-1(EN61000-4--2, 3, 4, and 6) Hazardous locations – ANSI / ISA 12.12.01, CSA C22.2/213 (Class 1, Div. 2), Groups A, B, C, D; ATEX IEC60079-0, -15 (Zone 2) Install the IP67 Industrial Ethernet Switch in accordance with local and national electrical codes. Lightning Danger: Do not work on equipment during periods of lightning activity. Do not connect a telephone line into one of the Ethernet RJ45 connectors. © 2014. Red Lion Controls. All Rights Reserved. 6 IP67 Switch Manual 2 LED Indicators 2.1 Overview The IP67 Industrial Ethernet Switch has communication LEDs for each port and a power LED. 2.2 Power LED This LED will be on solid when proper power has been applied to the unit. 2.3 ACT / LNK LEDs The activity (ACT) and link (LNK) indication is combined into one LED on the IP67 Industrial Ethernet Switch. There is one of these LEDs per port. OFF – This would indicate that there is not a proper Ethernet connection (Link) between the port and another Ethernet device. Make sure the proper cable type is in use and that it has been plugged securely into the ports at both ends. See section 5 for proper Ethernet cabling. ON Solid (not flashing) – This would indicate that there is a proper Ethernet connection (Link) between the port and another Ethernet device, but no communications activity is detected. Flashing - This would indicate that there is a proper Ethernet connection (Link) between the port and another Ethernet device, and that there is communications activity. 2.4 10 / 100 LEDs This LED indicates what speed of communications is detected on the port. There is one of these LEDs per RJ45 port. (The fiber optic port does not have one of these LEDs because its speed is fixed at 100 Mbps.) OFF – A 10 Mbps (10BaseT) connection is detected. ON – A 100 Mbps (100BaseTx) connection is detected. (Mbps = Megabits per Second) © 2014. Red Lion Controls. All Rights Reserved. 7 IP67 Switch Manual 3 Dimensions and Installation 3.1 Overview The IP67 Industrial Ethernet Switch is waterproof and therefore can be mounted directly to any flat surface. Refer to the mechanical drawings below. 2.10" (53 mm) 0.50" (13 mm) Ø0.20" (5 mm) 3.75" (95 mm) 2.95" (75 mm) 0.45" (11 mm) 10.15" (258 mm) 10.75" (273 mm) EB-GT-8ES-# (IP67 Industrial Ethernet Switch) EB-CC-PS-F# (Field Installable IP67 Power Connector) © 2014. Red Lion Controls. All Rights Reserved. 8 IP67 Switch Manual EB-CP-RJ45-F# (RJ45 to RJ45 IP67 Bulkhead Passthru Connector) (Required hole size = 1.063” (27mm)) EB-CC-CAT5-M# (Field Installable IP67 RJ45 Connector) © 2014. Red Lion Controls. All Rights Reserved. 9 IP67 Switch Manual 4 Power Wiring 4.1 Overview The IP67 Industrial Ethernet Switch can be powered from the same DC source that is used to power your I/O devices. 10 to 30 VDC needs to be applied to the mating DC power connector (supplied with the switch). The integrated screw terminals can accept up to 16 AWG wire. Refer to the wiring diagrams below. Male Power Connector on Switch Screw Terminal Side of Field Installable Power Connector 4.2 Connector Assembly The assembly of the field installable power connector (EB-CC-PS-F1) requires no special tools, just a standard small slotted screwdriver. The power cable should be between 6 and 8 mm in diameter. Simply install the components in the order shown below. First, strip off 1/4” of the plastic sheathing on each conductor of your power cable. Tightly twist stranded cable so there are no loose strands. Second, slide component 1, then 2, then 3 over your power cable in the orientation shown below. Keep these first 3 components loose. Do not tighten them yet. Third, using the integrated screw terminals, attach component 4 to the appropriate conductors of your power cable. Refer to the wiring diagram above. Fourth, screw component 3 to component 4. Finally, slide component 2 into component 3 and then screw component 1 to component 3. You now have a watertight IP67 power connector. 4 3 2 1 Note: The strain relief / seal section should be screwed in 2 turns (after initial thread engagement) on 6.8 mm diameter wire. Red Lion suggests 3 turns if 6 mm wire is used and no more than 2 turns if 8 mm wire is used to ensure a proper waterproof seal. © 2014. Red Lion Controls. All Rights Reserved. 10 IP67 Switch Manual 5 Ethernet Wiring 5.1 Overview The IP67 Industrial Ethernet Switch provides connections to Ethernet devices on the factory floor. Any uplink port can be used to connect to another Ethernet switch or hub that is connected to the main Ethernet backbone. The other Ethernet ports are then connected to Ethernet devices such as PLCs, Ethernet I/O, or industrial computers. Electrical isolation is provided on the Ethernet ports for increased reliability. Please follow normal 10/100BaseT(x) & 100BaseFX wiring practices when installing the IP67 Industrial Ethernet Switch. TYPICAL INDUSTRIAL ETHERNET SWITCH INSTALLATION 5.2 Ethernet RJ45 Wiring Guidelines Ethernet RJ45 Cable Type Use data-quality (not voice-quality) twisted pair cable rated category 5. For best performance use shielded cable. Please note that these cables are available or can be wired as straight-thru or cross-over configurations. For connections to the IP67 switch, either cable type will work because the IP67 switch supports auto-crossover (automdi/mdix) and will auto-detect the cable and adjust accordingly. Straight-thru Cable Wiring Cross-over Cable Wiring Pin 1 Pin 1 Pin 1 Pin 3 Pin 2 Pin 3 Pin 6 Pin 2 Pin 3 Pin 6 Pin 2 Pin 3 Pin 6 Pin 6 Pin 1 Pin 2 © 2014. Red Lion Controls. All Rights Reserved. 11 IP67 Switch Manual ETHERNET CONNECTOR Pin Positions Pin # 1 2 3 6 Assignment TX+ TXRX+ RX- ETHERNET CONNECTOR Pin Assignments Cable Distance The maximum cable length for 10/100BaseT(x) is typically 100 meters (328 ft.). Refer to the following chart for some general guidelines. From Switch 10Mbps Hub Switch or Hub To Switch or Hub 10Mbps Hub PLC, Ethernet I/O, PC, etc. Maximum Distance 100 meters (328 feet) 100 meters (328 feet) 100 meters (328 feet) Note: Hubs and Switches are different devices. Hubs simply broadcast all messages out all ports. Switches intelligently route messages only out the appropriate port. The device described in this manual is a Switch. 5.3 Field Installable RJ45 Connector The field installable RJ45 connector (EB-CC-CAT5-M#) is easy to install. A standard RJ45 crimping tool is required. Follow the instructions that come with the tool on how to attach the supplied RJ45 connector to your Ethernet cable. Category 5E cable is highly recommended. See the upcoming instructions for exact details on how to assemble this connector. Simply install the components in the order shown below. First, slide the o-ring over component 3 if it isn’t already. Second, slide component 1, then 2, then 3 over your un-terminated Ethernet cable in the orientation show below. Keep these first 3 components loose. Do not tighten them yet. Third, using your crimping tool, attach the supplied RJ45 connector to your Ethernet cable. Follow the instructions that come with your crimping tool. Fourth, push the attached © 2014. Red Lion Controls. All Rights Reserved. 12 IP67 Switch Manual RJ45 connector firmly into component 3. Fifth, firmly screw component 2 to component 3. Finally, slide component 1 up over component 3. You now have a watertight IP67 RJ45 Ethernet connector. Note: You may have also been supplied a “C” retaining clip. It’s recommended that you test your cable before installing this retaining clip to component 3. 4 3 2 1 5.4 Bulkhead Connector The RJ45 to RJ45 passthru bulkhead connector is also simple to install. First, punch a 1.063” (27 mm) diameter (3/4” conduit punch out) hole in your cabinet or panel. Remove the ¾” conduit nut. If you are going to install the tethered cap (supplied) then also remove the rubber gasket. Slide the integrated-gasket end of the tether over where the original gasket was located. It’s not recommended to use both gaskets at the same time. Insert the assembly into your hole (punch out) from the outside. Then firmly screw on the ¾” conduit nut from the inside. Recommended tightening torque is 6 in-lbs (.07 kg-m). You now have a watertight IP67 RJ45 to RJ45 passthru connector. © 2014. Red Lion Controls. All Rights Reserved. 13 IP67 Switch Manual 6 Switching Features 6.1 Switching Features Here are brief explanations of the features found in the IP67 Industrial Ethernet Switch documented by this manual. 10BaseT and 100BaseTx Auto-detection Standard Ethernet (10BaseT) has a maximum speed of 10 Mbps in half duplex mode. Fast Ethernet (100BaseTx) has a maximum speed of 200 Mbps in full duplex mode. The RJ45 ports on the IP67 Industrial Ethernet Switch will automatically select the appropriate speed. 2.0 Gbps combined bandwidth With full duplex and 100BaseTX communications, each port can provide a full 200 Mbps of data throughput. 1K MAC addresses with automatic learning, aging and migration Each Ethernet device inserts its unique “MAC” address into each message it sends out. The port on the switch used for a given MAC address is automatically learned when a frame is received from that address. Once an address is learned, the switch will route messages to only the appropriate port, instead of broadcasting messages out all ports like a hub. A time stamp is also placed in memory when a new address is learned. This time stamp is used with the aging feature, which will remove unused MAC addresses from the table after 300 seconds. If a device moves, the associated port on the switch will be changed (migrated) as needed. Up to 1,024 MAC addresses can be stored and monitored at any time. Auto-crossover (auto-mdi/mdi-x) The RJ45 ports will automatically detect the cable type (straight-thru vs. cross-wired) and re-configure themselves accordingly. Auto-sensing or auto-negotiating speed The RJ45 ports of the IP67 Industrial Ethernet Switch will auto-negotiate with the connected device to determine the optimal speed (10 Mbps vs. 100 Mbps) for each port. Automatic Power Saving If there is no cable on a port, most of the circuitry for that port is disabled to save power. Backoff Operation The IP67 Industrial Ethernet Switch will drop a packet after 16 collisions. Back Pressure for Half-Duplex The IP67 Industrial Ethernet Switch will apply “back pressure” when necessary with half-duplex operation. This “back pressure” will reduce congestion on busy networks. Broadcast Storm Protection Broadcast messages are limited to 5% of the available bandwidth. Unicast and multicast messages are not limited. Buffering SRAM is used for buffering the messages. There are 1024 (128 bytes each) buffers available. Each port is allocated 113 buffers. Unmanaged operation The IP67 Industrial Ethernet Switch requires no supervisory processor to operate properly. © 2014. Red Lion Controls. All Rights Reserved. 14 IP67 Switch Manual Flow control The IP67 Industrial Ethernet Switch automatically supports flow control frames on both the transmit and receive sides. Forwarding The IP67 Industrial Ethernet Switch supports store and forward mode. It will forward messages with known addresses out only the appropriate port. Messages with unknown addresses, broadcast messages, and multicast messages will get forwarded out all ports except the source port. The IP67 Industrial Ethernet Switch will not forward error packets, 802.3x pause frames, or “local” packets. Full/Half duplex operation The RJ45 ports of the IP67 Industrial Ethernet Switch support both full and half duplex flow control. Illegal frames Illegal frames as defined by IEEE 802.3 will be dropped. This includes short frames, long frames, and FCS error frames. IEEE 802.3 compliant The IP67 Industrial Ethernet Switch strictly abides to the IEEE 802.3 standard for 10BaseT and 100BaseTX Ethernet communications. Late collision If a packet experiences collisions after 512 bit times of transmission, the packet will be dropped. Latency The typical latency of a message is 5 microseconds or faster. The latency is the time it takes a message to be routed internal to a switch from one port to another. Plug and play This means that most functions or features of the IP67 Industrial Ethernet Switch are automatic and that there are minimal or no optional parameters that need to be set. Just plug in your Ethernet cables, apply power, and the unit will immediately begin to operate. Protocol independent The IP67 Industrial Ethernet Switch will work with all popular Ethernet protocols and networks such as TCP/IP, the Internet (IP), UDP, NetBEUI, and many more. It is compatible with all protocols that run over standard Ethernet (IEEE 802.3). In fact, it will support packets of different protocols simultaneously. © 2014. Red Lion Controls. All Rights Reserved. 15 IP67 Switch Manual 7 Technical Specifications Here are the technical specifications for the SixTRAK IPm Open Controller, VersaTRAK IPm RTU, and SixTRAK I/O. Industrial Ethernet Switch: EB-GT-8ES-1 10/100BaseT(x) Ports: 10/100BaseT(x) ports Protocols supported Ethernet compliancy Auto-mdi/mdix crossover Auto-negotiating speed Flow control Ethernet isolation Plug and play Cable requirements Max. cable distance General: Forwarding mode Latency (typical) Memory bandwidth MAC addresses Address learning Address aging Address migration Backoff operation Back pressure Broadcast storm protection Buffering Illegal frames Late collisions Environmental: Required supply voltage Power consumption Power saving Operating temp. range Storage temp. range Humidity Flammability Electrical safety EMI emissions EMC immunity Surge withstand Vibration Hazardous locations Environmental Rating Weight Shielded RJ45 All standard IEEE 802.3 IEEE 802.3 All 8 ports 10BaseT or 100BaseTX Half or Full Duplex 1500 VRMS 1 minute Yes Twisted pair (Cat. 5) (shielded recommended) 100 meters Store and forward 5 usec (time to route a message from one port to another internal to switch) 2.0 Gbps 1K Automatic Remove old address after 300s Automatic Drops after 16 collisions Automatic for half-duplex Limits to 5% of bandwidth 113 buffers per port (128 bytes per buffer) Dropped per 802.3 Dropped after 512 bit times 10 – 30 VDC (-1) ; +/- 16-40 VDC (-1EP) 4.0 W Typical Automatic -40 to 70° C (-1) ; -40 TO 60°C (-1EP) -40 to 85° C 5 to 100 % RH UL 94V-0 materials UL508, CSA C22/14; EN61010-1 (IEC1010), CE FCC part 15, ICES 003, EN55022; Class B; CE EN61326-1 (EN61000-4-2, 3, 4, and 6), CE IEEE-472 IEC68-2-6 ANSI / ISA12.12.01, CSA C22.2/213 (Class 1, Div. 2), ATEX IEC600790, -15 (Zone 2) IEC IP67 and NEMA 6 2.5 lbs. © 2014. Red Lion Controls. All Rights Reserved. 16 IP67 Switch Manual RJ45 to RJ45 Passthru Bulkhead Connector: EB-CP-RJ45-F# (includes cap with tether) Gasket Material Insert Material Overmold Material Coupling Nut Material Shell Material Knockout Hole Thread Size Operating Temperature Return Loss Environmental Rating TIA/EIA Rating Jacks Plating Current Rating Voltage Rating Recommended Tightening Torque Nitrile Rubber Acrylonitrile-Butadiene-Styrene (ABS) Polyurethane Acrylonitrile-Butadiene-Styrene (ABS) Acrylonitrile-Butadiene-Styrene (ABS) 1.063 UNC 1" - 14" -40º to 85º C 5 Db @ 100 Mhz IEC IP67 and NEMA 6 Category 5e RJ-45 50 Microns of Gold over 100 Microns Of Nickel 1.5 A 125V DC 6 in-lbs (.07 kg-m) Field Installable RJ45 Connector: EB-CC-CAT5-M# O-Ring Material Insert Material Overmold Material Coupling Nut Material Shell Material Thread Size Recommended cable diameter Operating Temperature Environmental Rating Nitrile Rubber Acrylonitrile-Butadiene-Styrene (ABS) Polyurethane Acrylonitrile-Butadiene-Styrene (ABS) Acrylonitrile-Butadiene-Styrene (ABS) UNC 1" - 14 Accepts 4 - 6 mm Cable -40º to 85º C IEC IP67 and NEMA 6 Field Installable Power Connector: EB-CC-PS-F# Housing Connector Contacts Coupling Nuts Conductors Ratings PG 9 Cable Gland Operating Temperature Environmental Rating Glass Filled Nylon Pur. Brass, Gold over Nickel Plating Anodized Aluminum Accepts Up To 16 AWG 600V, 9A Accepts 6 - 8 mm Cable -40 to +85°C IEC IP67 and NEMA 6 Protective Cap with Tether: EB-CC-CAP-L# (for use with IP67 switch; not for use with bulkhead) Tether/Gasket Material Coupling Nut Material Thread Size Operating Temperature Environmental Rating Nitrile Rubber Acrylonitrile-Butadiene-Styrene (ABS) UNC 1" - 14 -40º to 85º C IEC IP67 and NEMA 6 © 2014. Red Lion Controls. All Rights Reserved. 17 IP67 Switch Manual 8 Service Information 8.1 Service Information We sincerely hope that you never experience a problem with any Red Lion product. If you do need service, call Red Lion at 1-877-432-9908 for Technical Support. A trained specialist will help you to quickly determine the source of the problem. Many problems are easily resolved with a single phone call. If it is necessary to return a unit to us, an RO (Repair Order) can be obtained on the Red Lion website. Red Lion tracks the flow of returned material with our RO system to ensure speedy service. You must include this RO number on the outside of the box so that your return can be processed immediately. Be sure to have your original purchase order number and date purchased available. We suggest that you give us a repair purchase order number in case the repair is not covered under our warranty. You will not be billed if the repair is covered under warranty. Please supply us with as many details about the problem as you can. The information you supply will be written on the RO form and supplied to the repair department before your unit arrives. This helps us to provide you with the best service, in the fastest manner. Repairs are completed as soon as possible. If you need a quicker turnaround, ship the unit to us by air freight. We give priority service to equipment that arrives by overnight delivery. We apologize for any inconvenience that the need for repair may cause you. We hope that our rapid service meets your needs. If you have any suggestions to help us improve our service, please give us a call. We appreciate your ideas and will respond to them. For Your Convenience: Please fill in the following and keep this manual with your Red Lion system for future reference: P.O. #:__________________ Date Purchased: ___________________ Purchased From:______________________________________________ 8.2 Product Support Contact Red Lion Technical Support: Phone: +1 877 432 9908 Fax: +1 (518) 877-8346 E-mail: support@redlion.net Website: www.redlion.net Our address: Red Lion Controls 20 Willow Springs Circle York, PA 17406 © 2014. Red Lion Controls. All Rights Reserved. 18
EB-CC-CAT5-M4 价格&库存

很抱歉,暂时无法提供与“EB-CC-CAT5-M4”相匹配的价格&库存,您可以联系我们找货

免费人工找货