Issued by Module Components Div, TAMURA CORPORATION
Hall Effect Current Sensors L18P***S12 Series
Features:
Advantage:
Open Loop type
Printed circuit board mounting
Integrated primary
Unipolar power supply
Busbar version from 40A to 60A
Insulated plastic case according
to UL94V0
Regulated offset voltage
UL Recognition
Specifications
Excellent accuracy and linearity
Wide nominal current range
Low temperature drift
Wide frequency bandwidth
No insertion loss
High Immunity To External Interference
Optimised response time
Current overload capability
TA=25ºC, VCC=+12V, RL=10kΩ
L18P003 L18P005 L18P010 L18P015 L18P020 L18P025 L18P030 L18P040 L18P050 L18P060
Symbol
S12
S12
S12
S12
S12
S12
S12
S12
S12
S12
Parameters
Primary nominal current
3A
If
5A
10A
15A
20A
25A
30A
40A
50A
Ifmax
≥ ± If x 1.25
Rated output voltage
Vo
Vof +1.5V ± 0.045V (at If)
Offset voltage1
Vof
2.5V ± 0.035V (at If=0A)
Output linearity2(0A~If)
εL
≤ ± 1% (at If)
Power supply voltage
VCC
+12V ± 5%
Consumption current
Icc
≤ 15mA
Response time3
tr
≤ 5μs (at di/dt = If / μs)
Thermal drift of gain4
TcVo
≤ ±2.0mV/ºC
Thermal drift of offset
TcVof
≤ ±2.0mV/ºC
VOH
≤ 25mV (at If=0A→If→0A)
Insulation voltage
Vd
AC3000V for 1minute (sensing current 0.5mA), primary secondary
Insulation resistance
RIS
≥ 500MΩ (at DC500V), primary secondary
TA
-30ºC~+80ºC
TS
-40ºC~+85ºC
Saturation current
Hysteresis error
Ambient operation temperature
Ambient storage temperature
60A
1
Vof is fixed (independent of VCC). After removal of core hysteresis— 2 Without offset — 3 Time between 10% input current full scale and 90% of sensor output full scale — 4 Without Thermal drift of offset
Electrical Performances
Frequency characteristic(L18P025S12)
6
2
Output voltage (V)
Attenuation (dB)
4
0
-2
-4
-6
-8
-10
0.1
1
10
Frequency characteristic(kHz)
@ If=3(Arms)
L18PXXXS12revD, March 2012
100
Saturation characteristic(L18P025S12)
6.0
5.5
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
TA=25ºC Pulsed
-50
-40
-30
-20
-10
0
10
Input current (A)
Tamura reserve the right to modify its products in order to improve them without prior notice
20
30
40
50
Issued by Module Components Div, TAMURA CORPORATION
Hall Effect Current Sensors L18P***S12 Series
Mechanical dimensions
Terminal Number:
1: GND
2: GND
3: +VCC(+12V)
4: VOUT
5: Primary input current (+)
6: Primary input current (-)
The following,
table references
Current
3A
5A
10A
15A
20A
25A
30A
XXX
003
005
010
015
020
025
030
The following,
table references
φA
φ0.6
φ0.8
φ1.1
φ1.4
φ1.6
φ1.6
φ1.6
Current
40A
50A
60A
NOTES
1. Unit is mm
2. Tolerance is 0.5mm
XXX
040
050
060
Primary :Busbar
Electrical connection diagram
+If
+VCC
-If
RL = 10kΩ
GND
VOUT
UL Standard
UL 508 , CSA C22.2 No.14
(UL FILE No.E243511)
• For use in Pollution Degree 2 Environment.
• Maximum Surrounding air temperature rating, 80˚C.
Package & Weight Information
nominal current
Weight
Pcs/box
Pcs/carton
Pcs/pallet
10A..60A
8g
100
600
12000
3A , 5A
8g
50
1200
28800