Data Stream RS485 Digital Current Transducer
DIN RAIL / PANEL MOUNT
The CRD4100 Series Data Stream Digital Current Transducers
are designed for applications where AC current waveforms are
not purely sinusoidal. The digital technology is used to measure voltage, current, power frequency and energy in single and three phase
designs. The data is streamed over an RS485 IEEE bus which enables
multiple transducers to communicate thru a single master connection.
These advanced sensors are ideal for entire plant or zone monitoring.
Also, the communication alagorithm can be pre-ordered with ASCII
based control or modified MODBUS based control.
Sensing
True RMS Current, Each Phase
CRD4110
Single Element - .26” (6.5) Window
1 to 25 AAC Input Range
Applications
Features
35mm DIN Rail or Panel Mount
Red LED - Flashes when Power is Connected
Red & Green LED Flash during Communication
24 VDC powered
Use with external current transformers
Highest precision available
Connection diagram printed on case
CRD4150
Two Element - .26” (6.5) Window
1 to 25 AAC Input Range
Regulatory Agencies
CR Magnetics has a wide selection of Current and Potential
Transformers to extend the range of any part.
See Sections F & G for details.
CRD4170
Three Element - .26” (6.5) Window
1 to 25 AAC Input Range
PART NUMBERS
CRD4110
CRD4150
CRD4170
-
Single Element, AC Current RS485 Digital Transducer
Two Element, AC Current RS485 Digital Transducer
Three Element, AC Current RS485 Digital Transducer
1
5
15
25
-
0-1 AAC
0-5 AAC
0-15 AAC
0-25 AAC
Above 30 AAC must use 5 amp CT
The Professional
Energy Monitoring
Company
M N TI
ISO 9001:2008 Quality Management System
Note: Add an M at
the end for MODBUS
CRD4110-5-M
3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119
Web: http://www.crmagnetics.com
15
E-mail: sales@crmagnetics.com
Data Stream
Sub-Metering
Motor Loads
Uninterruptible Power Systems
Remote Monitoring
Load Shedding
Energy Management
B
RS485 Digital Current Transducer
SPECIFICATIONS
B
Basic Accuracy: .......................0.5%
Calibration: ..............................True RMS Sensing
Thermal Drift: ..........................500 PPM/°C
Operating Temperature1: ..........0°C to +60°C
Installation Category: ..............CAT II
Vibration Tested To: .................IEC 60068-2-6,1995
Pollution Degree: ....................2
Insulation Voltage: ..................2500 VDC
Altitude: ..................................2000 meter max
Frequency Range: .................20 Hz - 5 KHz
MTBF: ....................................Greater than 100K hours
Cleaning: ................................Water-dampened cloth
Supply Voltage2: ......................24 VDC ±10%
Torque Specifications: ....................3.0 inch lbs (0.4Nm)
Response Time: .......................250 ms. max. 0-90% FS
Relative Humidity:..............5% to 95%, Non-Condensing
Output Resolution: ..................................................16 bit
Transducer fanout on common bus: ...................64 max.
Baud Rate3: ...............1200, 2400, 4800, 9600,19.2K .bps
A/D Conversion Type: ..................4th order Delta Sigma
Device Address3: ............................................00 to FF
Data Format: .... .....................................................ASCII
Supply Current:..................Typical 30mA
Max 30mA
Weight:.. ..............................................................0.5 lbs.
1) RH 5% to 95%, non-condensing 2) 0.4% max. ripple Vpp
no flow control, 1 stop bit
Data Stream
3) Factory default settings:
LINE
N
N
address 01, baud rate 9600, no parity,
L1
L1
N
L2
L
L1
1
2
3
4
9
8
7
6
5
1
2
3
4
+ 485
-
+
L1
L1
L3
L3
L1
L1
N
N
1
2
3
4
-
+
L2
L2
L3
L3
9
8
7
6
5
-
+
485485
+ SUPPLY
SUPPLY
SUPPLY
SUPPLY
LOAD
LOAD
-
SUPPLY
1
2
3
4
+ 485
485
9
8
7
6
5
+
CRD4150 Dual Element, 3-Wire
CRD4110 Single Element, 2-Wire
L2
L2
-
SUPPLY
LOAD
LOAD
LOAD
+ 485
485
9
8
7
6
5
-
SUPPLY
LOAD
L2
L3
LOAD
LOAD
CRD4150 Dual Element, 3-Wire
CRD4170 3 Element, 4-Wire
Connection Diagram
CRD485-232
RS485 to RS232 Converter Accessory
Connect PC to RS485 Bus
RED INDICATIOR LED
GREEN INDICATOR LED
TX
[26.6]
1.05
[3.3]
.13
OPTIONAL
MOUNTING
DIN RAIL
MOUNTING
CLIP
[73.1]
2.88
[83.3]
3.28
RX
1
2
3
4
DATA STREAM
TRANSDUCER
[25]
.98
[31.0]
1.22
DATA +
9
8
7
6
5
DATAGND
+
[78.7]
3.10
MAX
[6.6]
.26
[28.3]
1.12
[88.7]
3.49
[35.0]
1.38
[36.6]
1.44
[13.5]
.53
[31.0]
1.22
[19.8] [19.8]
.78
.78
OUTLINE DRAWING
The Professional
Energy Monitoring
Company
M N TI
ISO 9001:2008 Quality Management System
-
COM
RS232
GND
DB 9, FEMALE
SUPPLY
[76.7]
[64] 3.02
2.52
[5.6]
.22
TYP
CRD485-232
+5VDC
ASCII Simplified Programming Commands
A simplified data structure is used with only 6 commands required for full control of
the transducer. Commands are : Read Transducer Name, Read Configuration, Set
Configuration, Read Measurements, Read Energy Totalizer and Clear Energy
Totalizer. For illustration, the following commands are used to read data from a
CRD5170 3 Phase, 4 Wire Transducer with a device address of 00.
Command Transducer to Read Data: #00A
Transducers Response: >+[% FS VoltageL1-N]+[% FS CurrentL1]+[% FS
VoltageL2-N]+[% FS CurrentL2]+[% FS VoltageL3-N]+[% FS CurrentL3,][+/- % FS
Power][+/-% FS VARS][+/-Power Factor][Frequency]
Command Transducer to Read Energy Totalizer: #00W
Transducer Responds: 01[+/-KWHr]{\[+/-KVHr][check sum]
Note: This is for illustration purposes only, See Applications Guides (Section I
for complete instructions.
3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119
Web: http://www.crmagnetics.com
16