DF-G2 High Speed Expert™ Dual Display
Fiber Amplifier
Instruction Manual
Original Instructions
177899 Rev. F
9 September 2021
© Banner Engineering Corp. All rights reserved
177899
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
Contents
1 Product Description
...................................................................................................................................................... 3
1.1 Models
.............................................................................................................................................................................................3
1.2 Overview
......................................................................................................................................................................................... 4
1.3 Top Panel Interface
..........................................................................................................................................................................4
2 Installation Instructions
............................................................................................................................................... 6
2.1 Mounting Instructions
......................................................................................................................................................................6
2.2 Installing the Fibers in a DF-Gx Sensor
........................................................................................................................................... 6
2.3 Fiber Adapters
.................................................................................................................................................................................7
2.4 Wiring Diagrams
..............................................................................................................................................................................7
3 Operating Instructions
................................................................................................................................................. 8
3.1 Run Mode
........................................................................................................................................................................................8
3.2 Program Mode
................................................................................................................................................................................ 8
3.2.1 TEACH Selection
.....................................................................................................................................................................9
3.2.2 Response Speed
................................................................................................................................................................... 10
3.2.3 Offset Percent
........................................................................................................................................................................10
3.2.4 Auto Thresholds
.................................................................................................................................................................... 10
3.2.5 Delays/Timers
........................................................................................................................................................................11
3.2.6 Gain Selection
....................................................................................................................................................................... 11
3.2.7 Factory Defaults
.................................................................................................................................................................... 11
3.3 Remote Input
..................................................................................................................................................................................11
3.4 Adjust Mode
.................................................................................................................................................................................. 13
3.4.1 Two-Point TEACH
.................................................................................................................................................................. 13
3.4.2 Dynamic TEACH
.................................................................................................................................................................... 14
3.4.3 Window SET
...........................................................................................................................................................................16
3.4.4 Light SET
................................................................................................................................................................................17
3.4.5 Dark SET
............................................................................................................................................................................... 19
3.4.6 Calibration SET
...................................................................................................................................................................... 21
3.4.7 Troubleshooting
.....................................................................................................................................................................22
4 Specifications
............................................................................................................................................................. 23
4.1 Excess Gain Curves
......................................................................................................................................................................24
4.2 Beam Patterns
............................................................................................................................................................................... 26
4.3 Dimensions
.................................................................................................................................................................................... 28
5 Accessories
.................................................................................................................................................................29
5.1 Quick-Disconnect Cordsets
...........................................................................................................................................................29
6 Banner Engineering Corp. Limited Warranty
...........................................................................................................31
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
1 Product Description
Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies
•
•
•
•
•
•
•
•
•
•
•
•
Best in class response speeds of: 10 µs, 15 µs, 50 µs, 250 µs, 500 µs, 1000 µs and
2000 µs allow the operator to optimize for fast response, long distance applications,
or noisy environments.
Outstanding color contrast sensitivity; detects 32 levels of gray scale from black to
white
Choose from IR or one of 4 visible beam colors: red, blue, green and white.
Depending on the beam color and fiber, the sensor reliably detects the toughest
color mark contrasts
Easy to read dual digital displays show both signal level and threshold
simultaneously
Lever action fiber clamp provides stable, reliable, and trouble-free fiber clamping
Simple user interface ensures easy sensor set-up and programming via displays
and switches/buttons or remote input teach wire
Expert TEACH and SET methods ensure optimal gain and threshold for all
applications, especially for high speed or low contrast applications
User has full control over all operating parameters: threshold, Light Operate or Dark
Operate, output timing functions, gain level, and response speed
Thermally stable electronics shorten start-up time and maintain signal stability during
operation
ECO (economy) display mode reduces amplifier power consumption by 25%
Cross talk avoidance algorithm allows two sensors to operate in close proximity for
many applications
Sleek 10 mm wide housing mounts to 35 mm DIN rail
WARNING:
• Do not use this device for personnel protection
• Using this device for personnel protection could result in serious injury or death.
• This device does not include the self-checking redundant circuitry necessary to allow its use in
personnel safety applications. A device failure or malfunction can cause either an energized (on)
or de-energized (off) output condition.
1.1 Models
Model
Sensing Beam Color
Reference Sensing Range 1
Visible Red
1100 mm
DF-G2-NS-2M
Outputs
Connector 2
Single NPN
DF-G2-PS-2M
Single PNP
DF-G2W-NS-2M
Single NPN
Broad Spectrum White
550 mm
DF-G2W-PS-2M
Single PNP
DF-G2G-NS-2M
Single NPN
2 m (6.5 ft) cable, 4-wire
Visible Green
660 mm
DF-G2G-PS-2M
Single PNP
DF-G2B-NS-2M
Single NPN
Visible Blue
DF-G2B-PS-2M
770 mm
Single PNP
1 Excess gain = 1, Long Range response speed, opposed mode sensing. PIT46U plastic fiber used for visible LED models, IT.83.3ST5M6 glass fiber
used for IR model
2 Connector options:
•
Models with a quick disconnect require a mating cordset (see Quick-Disconnect Cordsets on p. 29)
•
For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G2-NS-9M)
•
For 150 mm (6 in) PVC cable with a 4-pin M8 quick disconnect, change the suffix 2M to Q3 in the 2 m model number (example, DF-G2NS-Q3)
•
For 150 mm (6 in) PVC cable with a 4-pin M12 quick disconnect, change the suffix 2M to Q5 in the 2 m model number (example, DF-G2NS-Q5)
•
For integral 4-pin M8 quick disconnect, change the suffix 2M to Q7 in the 2 m model number (example, DF-G2-NS-Q7)
www.bannerengineering.com - Tel: + 1 888 373 6767
3
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
Model
Sensing Beam Color
Reference Sensing Range 1
Infrared
2100 mm
Outputs
DF-G2IR-NS-2M
Connector 2
Single NPN
DF-G2IR-PS-2M
Single PNP
1.2 Overview
The DF-G2 is an easy-to-use, DIN-rail-mountable fiber optic sensor with best in class response speed and repeatability. It
provides high-performance sensing in high speed or low contrast applications where fast response time is required.
The sensor’s compact housing has dual digital displays (Red/Green) and a bright output LED for easy programming and
status monitoring during operation. The sensor features a single discrete output, either NPN or PNP, by model.
The DF-G2 features improved temperature compensation compared with previous fiber optic sensors. An accessory clamp is
available to secure a bank of connected sensors together on a DIN rail (see Accessories on p. 29).
Figure 1. DF-G2 Model Features
1
Output LED
2
LO/DO Switch
3
RUN/PRG/ADJ Mode Switch
4
Lever Action Fiber Clamp
5
Red Signal Level
6
Green Threshold
7
+/SET/- Rocker Button
1.3 Top Panel Interface
Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ
mode switch, LO/DO switch, +/SET/- rocker button, dual red/green digital displays, and output LED.
RUN/PRG/ADJ Mode Switch
The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode. RUN mode
allows the sensor to operate normally and prevents unintentional programming changes via the +/SET/button. PRG mode allows the sensor to be programmed through the display driven programming menu (see
Program Mode on p. 8 ). ADJ mode allows the user to perform Expert TEACH/SET methods and Manual
Adjust (see Adjust Mode on p. 13 ).
LO/DO Switch
The LO/DO switch is used to select Light Operate or Dark Operate mode. In Light Operate mode, the output is
ON when the sensing condition is above the threshold (for Window SET, the output is ON when the sensing
condition is inside the window). In Dark Operate mode, the output is ON when the sensing condition is below
the threshold (for Window SET, the output is ON when the sensing condition is outside the window).
1 Excess gain = 1, Long Range response speed, opposed mode sensing. PIT46U plastic fiber used for visible LED models, IT.83.3ST5M6 glass fiber
used for IR model
2 Connector options:
•
Models with a quick disconnect require a mating cordset (see Quick-Disconnect Cordsets on p. 29)
•
For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G2-NS-9M)
•
For 150 mm (6 in) PVC cable with a 4-pin M8 quick disconnect, change the suffix 2M to Q3 in the 2 m model number (example, DF-G2NS-Q3)
•
For 150 mm (6 in) PVC cable with a 4-pin M12 quick disconnect, change the suffix 2M to Q5 in the 2 m model number (example, DF-G2NS-Q5)
•
For integral 4-pin M8 quick disconnect, change the suffix 2M to Q7 in the 2 m model number (example, DF-G2-NS-Q7)
4
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
+/SET/- Rocker Button
The +/SET/- rocker button is a 3-way button. The +/- positions are engaged by rocking the button left/right.
The SET position is engaged by clicking down the button while the rocker is in the middle position. All three
button positions are used during PRG mode to navigate the display driven programming menu. During ADJ
mode, SET is used to perform TEACH/SET methods and +/- are used to manually adjust the threshold(s). The
rocker button is disabled during RUN mode, except when using Window SET, see Window SET on p. 16.
Red/Green Digital Displays
During RUN and ADJ mode, the Red display shows the signal level and the Green display shows the
threshold. During PRG mode, both displays are used to navigate the display driven programming menu.
Output LED
The output LED provides a visible indication when the output is activated.
www.bannerengineering.com - Tel: + 1 888 373 6767
5
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
2 Installation Instructions
2.1 Mounting Instructions
Mount on a DIN Rail
1. Hook the DIN rail clip on the bottom of the DF-G2
over the edge of the DIN rail (1).
2. Push the DF-G2 up on the DIN rail (1).
3. Pivot the DF-G2 onto the DIN rail, pressing until it
snaps into place (2).
Mount to the Accessory Bracket (SA-DIN-BRACKET)
1. Position the DF-G2 in the SA-DIN-BRACKET.
2. Insert the supplied M3 screws.
3. Tighten the screws.
Remove from a DIN rail
1. Push the DF-G2 up on the DIN rail (1).
2. Pivot the DF-G2 away from the DIN rail and remove
it (2).
2.2 Installing the Fibers in a DF-Gx Sensor
Follow these steps to install glass or plastic fibers.
1.
2.
3.
4.
5.
Open the dust cover.
Move the fiber clamp forward to unlock it.
Insert the fiber(s) into the fiber port(s) until they stop.
Move the fiber clamp backward to lock the fiber(s).
Close the dust cover.
Move forward
to release the
fibers
Fiber Clamp
Fiber Receiver
Port
Fiber Emitter
Port
Note: For optimum performance of IR models, if applicable, glass fibers must be used.
6
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
2.3 Fiber Adapters
Note: If a thin fiber with less than 2.2 mm outer diameter is used, install the fiber adapter provided with the
fiber assembly to ensure a reliable fit in the fiber holder. Align the fibers to the end of the adaptors. Banner
includes the adapters with all fiber assemblies.
TO
FIBERS
TO
SENSOR
Fiber Outer Diameter (mm)
Adapter Color
Ø 1.0
Black
Ø 1.3
Red
Ø 2.2
No adapter needed
When connecting coaxial-type fiber assemblies to the amplifier, install the single-core (center) fiber to the Transmitter port,
and the multi-core (outer) fiber to the Receiver port. This will result in the most reliable detection.
RECEIVER
Multi-core fiber
Single-core fiber
TRANSMITTER
2.4 Wiring Diagrams
1
1
10-30V dc
3
4
2
Key
PNP Models
NPN Models
4
Load
Remote
Programming
(N.O.)
10-30V dc
3
2
1 = Brown
2 = White
3 = Blue
4 = Black
Load
Remote
Programming
(N.O.)
Open lead wires must be
connected to a terminal
block.
www.bannerengineering.com - Tel: + 1 888 373 6767
7
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
3 Operating Instructions
3.1 Run Mode
Run mode allows the sensor to operate normally and prevents unintentional programming changes. The +/SET/- rocker
button is disabled during RUN mode, except when using Window SET.
3.2 Program Mode
Program (PRG) mode allows the following settings to be programmed in the DF-G2 (refer to Program Mode Flowchart and
and Remote Input Flowchart for programming). See Factory Default Settings in Specifications.
8
www.bannerengineering.com - Tel: + 1 888 373 6767
Menu
List
Press and hold SET to exit
choice list without saving
DISPLAY
LOOP
DISPLAY
LOOP
Return to Menu List
Click SET
to enter choice list
Click SET
to enter choice list
Mode Switch
to “PRG”
PROGRAM MODE
Click SET
to enter choice list
Click SET
to enter choice list
Click SET
to enter choice list
Click SET
to enter choice list
on display represents a “w”
Click SET
to enter choice list
DISPLAY
LOOP
Click SET
to enter choice list
on display represents a “m”
Click SET to select and save a choice in any list
DISPLAY
LOOP
Click SET
to enter choice list
rocker button
DISPLAY
LOOP
Click SET
to enter choice list
DISPLAY
LOOP
Click SET
to enter choice list
To scroll through menu lists: Press “+” or “-”
To enter a choice list or to select and save: Click SET
To exit a choice list without saving: Press and hold SET for 2 seconds
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
Figure 2.
3.2.1 TEACH Selection
The DF-G2 can be programmed for one of the following TEACH/SET methods:
• Two-Point TEACH
• Dynamic TEACH
www.bannerengineering.com - Tel: + 1 888 373 6767
9
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
•
•
•
•
Window SET
Light SET
Dark SET
Calibration SET
Note: A TEACH Selection must be selected by programming before TEACH/SET methods can be used.
3.2.2 Response Speed
The DF-G2 can be programmed for one of the following Response Speeds:
Response Speed
Display Range
Crosstalk Avoidance Algorithm
10 µs (Super High Speed)
0 – 4000
Disabled
15 µs (High Speed)
0 – 4000
Disabled
50 µs (Fast)
0 – 4000
Disabled
250 µs (Standard)
0 – 4000
Enabled
500 µs (Medium Range)
0 – 9999
Enabled
1000 µs (Long Range)
0 – 9999
Enabled
2000 µs (Long Range with immunity to
Energy Efficient Lights)
0 – 9999
Enabled
3.2.3 Offset Percent
The Offset Percent is used during the Window, Light, or Dark SET methods. The threshold(s) are positioned a programmable
% offset from the taught condition.
The allowable range depends upon the Response Speed Mode, as shown below:
Response Speed
MIN %
MAX %
10 µs
5
999
15 µs
5
999
50 µs
2
999
250 µs
2
999
500 µs
1
999
1000 µs
1
999
2000 µs
1
999
The offset percent can also be programmed to Minimum Offset. This allows the DF-G2 to set the
threshold(s) as close as possible to the presented condition, but still provide for reliable sensing.
Note: Offset Percent MUST be programmed to Minimum Offset for Dark SET to accept conditions of no
signal (0 counts).
3.2.4 Auto Thresholds
Auto Thresholds can be programmed to be ON/OFF. The Auto Thresholds algorithm continuously tracks slow changes in the
taught condition(s), and optimizes the threshold(s) to provide for reliable sensing. For Two-Point and Dynamic TEACH, the
algorithm optimizes the threshold to be centered between the light and dark conditions. For Window, Light, and Dark SET,
the algorithm optimizes the threshold(s) to maintain the programmed Offset Percent from the taught condition.
• After programming Auto Thresholds to ON, it is highly recommended to re-perform the TEACH/SET method
• Manual Adjustments are disabled when Auto Thresholds are ON
• Auto Thresholds are automatically disabled in Calibration SET (see Calibration SET on p. 21)
10
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
•
Severe contamination/changes in the taught condition can prevent the Auto Thresholds algorithm from optimizing the
threshold(s). If this occurs, the DF-G2 enters a Threshold Alert or Threshold Error state. See Troubleshooting on p.
22 for more explanation.
3.2.5 Delays/Timers
ON/OFF Delays and ON/OFF One-Shot
timers can be programmed between 1 9999 ms (a value of 0 disables the delay/
timer). Figure 3 on p. 11 defines how the
delays/timers affect the output behavior.
Some combinations of delays/timers are not
allowed. The DF-G2 programming menu
automatically disables invalid combinations
of delays/timers. The following table shows
the allowable combinations of delays/timers:
Figure 3. DF-G2 Delays/Timers
ON
Output
OFF
OFF Delay
OFF 1-Shot
D
D
D
D
ON Delay
D
D
ON 1-Shot
D
D
Time
(D = 1 - 9999 ms)
OFF Delay
OFF One-Shot Timer
ON Delay
ON One-Shot Timer
-
OK
OK
N/A
OFF One-Shot Timer
OK
-
N/A
N/A
ON Delay
OK
N/A
-
OK
ON One-Shot Timer
N/A
N/A
OK
-
OFF Delay
3.2.6 Gain Selection
The DF-G2 can operate in Auto Gain mode or the Gain can be fixed to be in Gain 1...8. In Auto Gain, the DF-G2 optimizes
the gain during a TEACH/SET method for the presented condition(s). While viewing the fixed gains in the Gain Selection
choice list, the DF-G2 will automatically switch to the selected gain and display the measured signal on the Red display. This
allows for easy and quick evaluation of the fixed gain mode.
3.2.7 Factory Defaults
The Factory Defaults menu allows the DF-G2 to be easily restored back to original factory default settings (see Factory
Default Settings in Specifications).
Display Readout
The readout of the digital displays can be programmed for the following options:
• Signal/Threshold readout - Numeric (1234) or % (123P)
• ECO mode - Enabled or Disabled (ECO mode dims the displays to reduce current consumption)
) or Flipped (
)
• Display Orientation - Normal (
3.3 Remote Input
The remote input may be used to perform TEACH/SET methods and to program the sensor remotely. Connect the white
input wire of the sensor to ground (0 V DC), with a remote switch connected between them. Pulse the remote input according
to the diagram shown in Figure 4 on p. 12. Follow the instructions in the TEACH/SET sections in Adjust Mode on p. 13 to
perform a TEACH/SET method.
www.bannerengineering.com - Tel: + 1 888 373 6767
11
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
The sensor exits TEACH and remote programming modes after a 60 second timeout. Users may exit TEACH and remote
programming modes by setting the remote input low for more than 2 seconds. In either case, the sensor returns to Run mode
without saving any new settings.
Figure 4. Remote Input Flowchart
Remote
Input
NOTE: Follow procedure for the selected TEACH/SET method
(highlighted in black box) chosen in the TEACH Selection menu
Two Point TEACH 2Pt tch, then 1234 2nd
PASS or FAIL (with % Minimum Diff.)
Pulse Timing (T)
0.04 seconds < T < 0.8 seconds
Timing between Pulse groups > 1 second
1x
Dynamic TEACH dYn tch, then 1234 dYn
PASS or FAIL (with % Minimum Diff.)
1x
1x
or
TEACH METHODS
1x
Light SET Lt SEt then PASS or FAIL*
Dark SET dr SEt then PASS or FAIL*
Window SET wind SEt then PASS or FAIL*
Calibration SET CAL SET then PASS or FAIL
1x
1x
1x
1x
(continued from below)
PRO Advanced
3x
1x
* with % offset if not hard fail
PRO Basic
1x
TEACH Selection
1x
0 ms
3x
Window SET
Light SET
2x
2 ms
3x
Dark SET
CAL SET
4x
5 ms
10 ms
2x
5x
6x
Response Speed
10 µs (High-Speed)
2x
15 µs (Standard)
1x
0 ms
3x
50 µs (Long Range)
250 µs (Standard Speed)
500 µs (Medium Range)
1000 µs (Long Range)
2000 µs (Long Range with
immunity to energyefficient lights)
2x
2 ms
3x
5 ms
10 ms
5x
6x
7x
Offset Percent
Min. Offset
2% *
1x
2x
3x
4x
20%
50%
5x
6x
Off One-Shot
4x
5x
6x
4x
1x
0 ms
2x
2 ms
3x
5 ms
10 ms
5x
6x
5x
Button Lock
1x
0 ms
2 ms
5 ms
10 ms
20 ms
50 ms
1x
Button Unlock (uloc)
2x
Button Lock (loc)
3x
4x
Numeric
2x
Percent
3x
ECO Numeric
ECO Percent
Numeric Flipped
4x
5x
8x
PRO Advanced
6x
6x
Percent Flipped
ECO Numeric Flipped
ECO Percent Flipped
6x
7x
3x
5x
1x
(continued at top)
4x
Button Lock (loc) or Unlock (uloc)
8x
Factory Default Settings
* In Super High-Speed and High-Speed Responses, 2% offset is forced to Min. Offset
12
www.bannerengineering.com - Tel: + 1 888 373 6767
20 ms
50 ms
On One-Shot
2x
Display Readout
20 ms
50 ms
On Delay
4x
5%
10%
3x
5x
20 ms
50 ms
1x
4x
PROGRAM (Basic)
Off Delay
Dynamic TEACH
6x
4x
Auto Thresholds OFF
2 Pt. TEACH
5x
3x
Auto Thresholds ON
2x
2x
4x
2x
1x
1x
PROGRAM (Advanced)
2x
Auto Thresholds
Gain Select
1x
Auto Gain
2x
Gain 1
3x
Gain 2
Gain 3
4x
5x
6x
7x
8x
9x
Gain 4
Gain 5
Gain 6
Gain 7
Gain 8
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
3.4 Adjust Mode
Sliding the RUN/PRG/ADJ mode switch to the ADJ position allows the user to perform Expert TEACH/SET methods and
Manual Adjustment of the threshold(s).
3.4.1 Two-Point TEACH
• Establishes a single switching threshold
• Threshold can be adjusted by using the "+" and "-" rocker button (Manual Adjust)
Two-Point TEACH is used when two conditions can be presented statically to the sensor. The sensor locates a single
sensing threshold (the switch point) midway between the two taught conditions, with the Output ON condition on one side,
and the Output OFF condition on the other.
Figure 5. Two-Point TEACH (Light Operate shown)
Darkest Taught
Condition
Lightest Taught
Condition
Sensor positions
threshold midway
between taught conditions
Output OFF
Darkest
(no signal)
Output ON
Position
adjusted by
Manual Adjust
Most Light
(saturated
signal)
The Output ON and OFF conditions can be reversed by using the LO/DO (Light Operate/ Dark Operate) switch.
Two-Point TEACH and Manual Adjust
Moves switching threshold value up or down to make adjustments
•
•
•
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
◦ GREEN display shows the switching threshold value
◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Follow these steps to perform a Two-Point TEACH:
Note: TEACH Selection must be programmed to 2Pt tcH.
1. Enter Adjust mode.
Method
Action
Result
SET Button 3
Set the Mode switch to ADJ.
Display: Red - Signal Level; Green Threshold
Remote Input 4
No action is required; sensor is ready for
the Two-Point TEACH method
2. Teach the first condition.
3 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
4 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
www.bannerengineering.com - Tel: + 1 888 373 6767
13
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
Method
Action
Result
SET Button
a. Present the first condition.
Display: Flashes "2Pt tch" then holds
on "1234 2nd"
b. Click the SET rocker button.
Remote Input
a. Present the first condition.
T
b. Single-pulse the remote input.
3. Teach the second condition.
Method
Action
Result
SET Button
a. Present the second condition.
b. Click the SET rocker button.
TEACH Accepted
Remote Input
Displays alternate "PASS" and %
Minimum Difference 5; Sensor returns
to Adjust mode
a. Present the second condition.
b. Single-pulse the remote input.
T
TEACH Not Accepted
Displays alternate "FAIL" and %
Minimum Difference 5; Sensor returns
to Adjust mode
4. Return to Run mode.
Method
Action
Result
SET Button
Move the Mode switch to RUN
Display: Red - Signal Level; Green Threshold
Remote Input
No action is required; sensor returns to
RUN mode automatically
3.4.2 Dynamic TEACH
•
•
•
Teaches on-the-fly
Establishes a single switching threshold
Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actual
sensing conditions, taking multiple samples of the light and dark conditions and automatically setting the threshold at the
optimum level.
Figure 6. Dynamic TEACH (Light Operate shown)
Darkest Taught
Condition
Lightest Taught
Condition
Sensor positions
threshold midway
between taught conditions
Output OFF
Darkest
(no signal)
Output ON
Position
adjusted by
Manual Adjust
Most Light
(saturated
signal)
The output ON and OFF conditions can be reversed using the LO/DO switch.
5 See Troubleshooting on p. 22 for more explanation of the % Minimum Difference displayed after the Two-Point TEACH method.
14
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
Dynamic TEACH and Manual Adjust
•
•
•
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
◦ GREEN display shows the switching threshold value
◦ 2 seconds after adjustment, GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform Dynamic TEACH:
Note: TEACH Selection must be programmed to dYn tcH.
1. Enter Adjust Mode.
Method
Action
Result
SET Button 6
Set Mode switch to ADJ
Display: Red - Signal Level; Green Threshold
Remote Input 7
No action required; sensor is ready for
Dynamic TEACH method
2. Enter Dynamic TEACH.
Method
Action
Result
SET Button
Click the SET rocker button
Display: Flashes "dYn tch" then holds
on "1234 dYn"
Remote Input
Single-pulse remote input
T
3. Present ON and OFF Conditions.
Method
Action
Result
SET Button
Present ON and OFF conditions
Display: Red - Signal Level; Green Threshold
Remote Input
Present ON and OFF conditions
4. Exit Dynamic TEACH.
Method
Action
Result
SET Button
Click the SET rocker button
TEACH Accepted
Displays alternate "PASS" with %
Minimum Difference 8, Sensor returns
to Adjust mode
Remote Input
Single-pulse remote input
T
TEACH Not Accepted
Displays alternate "FAIL" with %
Minimum Difference 8, Sensor returns
to Adjust mode
6 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
7 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
8 See Troubleshooting on p. 22 for more explanation of the % Minimum Difference displayed after the Dynamic TEACH method.
www.bannerengineering.com - Tel: + 1 888 373 6767
15
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
5. Return to RUN Mode.
Method
Action
Result
SET Button
Move Mode switch to RUN
Display: Red - Signal Level; Green Threshold
Remote Input
No action required; sensor returns to
RUN mode automatically
3.4.3 Window SET
•
•
•
•
Sets window thresholds that extend a programmable % offset above and below the presented condition
All other conditions (lighter or darker) cause the output to change state
Sensing window center can be adjusted using "+" and "-" rocker button (Manual Adjust)
Recommended for applications where a product may not always appear in the same place, or when other signals
may appear
• See Program Mode for programming the Offset Percent setting
A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and
below the presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside
the window, and the Output OFF conditions outside the window.
Figure 7. Window SET (Light Operate shown)
Sensing window
center adjusted by
Manual Adjust
Output OFF
Darkest
(no signal)
Output ON
Sensor positions
window thresholds
a programmable %
offset from the
presented condition
Output OFF
Condition
Presented
Most Light
(saturated
signal)
Output ON and OFF conditions can be reversed using the LO/DO switch.
Moves sensing window center value up or down to make adjustments
•
•
•
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
◦ GREEN display shows the sensing window center value
◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Window SET:
Note: TEACH Selection must be programmed to wind SEt.
1. Enter Adjust Mode
16
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
Method
Action
Result
SET Button 9
Set Mode switch to ADJ
Display: Red - Signal Level; Green Threshold
Remote Input 10
No action required; sensor is ready for
Window SET method
2. SET Sensing Condition
Method
Action
Result
SET Button
•
•
Present sensing condition
Click the SET rocker button
Remote Input
•
•
Present sensing condition
Single-pulse the remote input
Threshold Condition Accepted
Displays read "wInd SEt" then
alternate "PASS" with % Offset 11;
Sensor returns to Adjust mode
T
Threshold Condition Not Accepted
Displays read "wInd SEt" then
alternate "FAIL" with minimum %
Offset 11 for sensing condition; Sensor
returns to Adjust mode
3. Return to RUN Mode
Method
Action
Result
SET Button
Move Mode switch to Run
Remote Input
No action required; sensor returns to
Run mode automatically
Display: Red - Signal Level; Green Window Center (see Figure 8 on p.
17 for instructions on how to display
upper and lower thresholds)
Figure 8. Upper and Lower Thresholds
Window SET (during RUN mode)
Upon sensor power-up, Window Center is displayed
Upper
Threshold
Displayed
Window
Center
Displayed
Lower
Threshold
Displayed
3.4.4 Light SET
•
•
•
Sets a threshold a programmable % offset below the presented condition
Changes output state on any condition darker than the threshold condition
Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
9 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
10 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
11 See Troubleshooting on p. 22 for more explanation of the % Offset displayed after the Window SET method
www.bannerengineering.com - Tel: + 1 888 373 6767
17
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
•
Recommended for applications where only one condition is known, for example a stable light background with
varying darker targets
• See Program Mode for programming the Offset Percent setting
A single sensing condition is presented, and the sensor positions a threshold a programmable % offset below the presented
condition. When a condition darker than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO
setting.
Figure 9. Light SET (Light Operate shown)
Threshold position
adjusted by
Manual Adjust
Sensor positions
threshold a programmable
% offset below the
presented condition
Output OFF
Darkest
(no signal)
Output ON
Condition
Presented
Most Light
(saturated
signal)
Light SET and Manual Adjust
Moves switching threshold value up or down to make adjustments
•
•
•
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
◦ GREEN display shows the switching threshold value
◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Light SET:
Note: TEACH Selection must be programmed to Lt SEt.
1. Enter Adjust Mode
Method
Action
Result
SET Button 12
Set Mode switch to ADJ
Display: Red - Signal Level; Green Threshold
Remote Input 13
No action is required; sensor is ready for
Light SET method
2. SET Sensing Condition
12 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
13 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
18
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
Method
Action
Result
SET Button
•
•
Present sensing condition
Click the SET rocker button
Remote Input
•
•
Present sensing condition
Single-pulse the remote input
Threshold Condition Accepted
Displays read "Lt SEt" then alternate
"PASS" with % Offset 14; Sensor
returns to Adjust mode
T
Threshold Condition Not Accepted
Displays read "Lt SEt" then alternate
"FAIL" with minimum % Offset 14 for
sensing condition; Sensor returns to
Adjust mode
3. Return to RUN Mode
Method
Action
Result
SET Button
Move Mode switch to RUN
Display: Red - Signal Level; Green Threshold
Remote Input
No action required; sensor returns to
RUN mode automatically
3.4.5 Dark SET
•
•
•
•
•
Sets a threshold a programmable % offset above the presented condition
Any condition lighter than the threshold condition causes the output to change state
Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
Recommended for applications where only one condition is known, for example a stable dark background with
varying lighter targets
See Program Mode for programming the Offset Percent setting
Note: Offset Percent MUST be programmed to Minimum Offset to accept conditions of no signal (0
counts).
A single sensing condition is presented, and the sensor positions a threshold a programmable % offset above the presented
condition. When a condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO
setting.
Figure 10. Dark SET (Light Operate shown)
Threshold position
adjusted by
Manual Adjust
Sensor positions
threshold a programmable
% offset above the
presented condition
Output OFF
Darkest
(no signal)
Condition
Presented
Output ON
Most Light
(saturated
signal)
14 See Troubleshooting on p. 22 for more explanation of the % Offset displayed after the Light SET method
www.bannerengineering.com - Tel: + 1 888 373 6767
19
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
Dark SET and Manual Adjust
Moves switching threshold value up or down to make adjustments
•
•
•
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
◦ GREEN display shows the switching threshold value
◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Dark SET:
Note: TEACH Selection must be programmed to dr SEt.
1. Enter Adjust Mode.
Method
Action
Result
SET Button 15
Set Mode switch to ADJ
Display: Red - Signal Level; Green Threshold
Remote Input 16
No action required; sensor is ready for
Dark SET method
2. SET Sensing Condition.
Method
Action
Result
SET Button
•
•
Present sensing condition
Click the SET rocker button
Remote Input
•
•
Present sensing condition
Single-pulse the remote input
Threshold Condition Accepted
Displays read "dr SEt" then alternate
"PASS" with % Offset 17; Sensor
returns to Adjust mode
T
Threshold Condition Not Accepted
Displays read "dr SEt" then alternate
"FAIL" with minimum % Offset 17 for
sensing condition; Sensor returns to
Adjust mode
3. Return to RUN Mode.
Method
Action
Result
SET Button
Move Mode switch to RUN
Display: Red - Signal Level; Green Threshold
Remote Input
No action required; sensor returns to
RUN mode automatically
15 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
16 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
17 See Troubleshooting on p. 22 for more explanation of the % Offset displayed after the Dark SET method
20
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
3.4.6 Calibration SET
• Sets a threshold exactly at the presented condition
• Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
A single sensing condition is presented, and the sensor positions a threshold exactly at the presented condition. When a
condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting.
Figure 11. Calibration SET (Light Operate shown)
Threshold position
adjusted by
Manual Adjust
Sensor positions
threshold exactly at
the presented condition
Output OFF
Darkest
(no signal)
Output ON
Condition
Presented
Most Light
(saturated
signal)
Calibration SET and Manual Adjust
Moves switching threshold value up or down to make adjustments
•
•
•
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
◦ GREEN display shows the switching threshold value
◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Auto Thresholding is automatically disabled in Calibration SET
Follow these steps to perform a Calibration SET:
Note: TEACH Selection must be programmed to CAL SEt.
1. Enter Adjust Mode
Method
Action
SET Button 18
Remote Input 19
•
Result
Set Mode switch to ADJ
Display: Red - Signal Level; Green Threshold
No action required; sensor is ready for
Calibration SET method
2. SET Sensing Condition
Method
Action
Result
SET Button
•
•
Present sensing condition
Click the SET rocker button
Remote Input
•
•
Present sensing condition
Single-pulse the remote input
Threshold Condition Accepted
Displays read "cAL SEt" then flashes
"PASS"; Sensor returns to Adjust mode
T
Threshold Condition Unacceptable
Displays read "cAL SEt" then flashes
"FAIL"; Sensor returns to Adjust mode
18 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
19 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
www.bannerengineering.com - Tel: + 1 888 373 6767
21
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
3. Return to RUN Mode
Method
Action
Result
SET Button
Move Mode switch to RUN
Display: Red - Signal Level; Green Threshold
Remote Input
No action required; sensor returns to
RUN mode automatically
3.4.7 Troubleshooting
Manual Adjustments Disabled
Manual adjustments are disabled when Auto Thresholds are ON. If a manual adjustment is attempted while Auto Thresholds
are ON, the Green display will flash
.
Percent Minimum Difference after TEACH
The Two-Point and Dynamic TEACH methods will flash a % minimum difference on the displays after a PASS or FAIL.
Value
PASS/FAIL
Description
0 to 99%
FAIL
The difference of the taught conditions does not meet the required minimum
100 to 300%
PASS
The difference of the taught conditions just meets/exceeds the required minimum, minor
sensing variables may affect sensing reliability
300 to 600%
PASS
The difference of the taught conditions sufficiently exceeds the required minimum, minor
sensing variables will not affect sensing reliability
600% +
PASS
The difference of the taught conditions greatly exceeds the required minimum, very
stable operation
Percent Offset after SET
The Window, Dark, and Light SET methods will flash a % offset on the displays after a PASS or FAIL.
SET Result
% Offset Meaning
PASS (with % Offset)
Displays the % offset used for the SET method
FAIL (with % Offset)
Displays the minimum required % offset necessary to PASS the SET method
FAIL (without % Offset)
Presented condition cannot be used for the SET method
Threshold Alert or Threshold Error
Severe contamination/changes in the taught condition can prevent the Auto Thresholds algorithm from optimizing the
threshold(s).
State
Display
Description
Corrective Action
Threshold Alert
Alternates
The threshold(s) cannot be
optimized, but the sensor's output
will still continue to function
Cleaning/correcting the sensing
environment and/or a re-teach of the
sensor is highly recommended
The threshold(s) cannot be
optimized, and the sensor's output
will stop functioning
Cleaning/correcting the sensing
environment and/or a re-teach of the
sensor is required
and
Threshold Error
22
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
4 Specifications
Sensing Beam
DF-G2: Visible red, 635 nm
DF-G2W: Broad spectrum white, 450 nm to 650 nm
DF-G2B: Visible blue, 470 nm
DF-G2G: Visible green, 525 nm
DF-G2IR: Infrared, 850 nm
Supply Voltage
10 V DC to 30 V DC Class 2 (10% maximum ripple)
Power and Current Consumption (exclusive of load)
Standard display mode: 960 mW, Current consumption < 40 mA at 24 V
DC
ECO display mode: 720 mW, Current consumption < 30 mA at 24 V DC
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Delay at Power-Up
500 milliseconds maximum; outputs do not conduct during this time
Output Configuration
1 NPN or 1 PNP output, depending on model
Output Rating
100 mA maximum load (derate 1 mA per °C above 30 °C)
OFF-state leakage current: < 5 μA at 30 V DC;
ON-state saturation voltage: NPN: < 1.5 V; PNP : < 2 V
Output Protection
Protected against output short-circuit, continuous overload, transient
overvoltages, and false pulse on power-up
Output Response Time
Super High Speed: 10 µs
High Speed: 15 µs
Fast: 50 µs
Standard: 250 µs
Medium Range: 500 µs
Long Range: 1000 µs
Long Range with immunity to Energy Efficient Lights: 2000 µs
Repeatability
Super High Speed: 5 µs
High Speed: 5 µs
Fast: 12 µs
Standard: 50 µs
Medium Range: 80 µs
Long Range: 165 µs
Long Range with immunity to Energy Efficient Lights: 165 µs
Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in accordance with
local and national electrical codes and
regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current
Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20
5.0
22
3.0
24
2.0
26
1.0
28
0.8
30
0.5
Adjustments
3-way RUN/PRG/ADJ Mode Switch
2-way LO/DO Switch
3-way +/SET/- Rocker Button
•
Expert-style teaching (Two-Point and Dynamic TEACH,
Light/Dark/Window/Calibration SET)
•
Manually adjust sensitivity (from "+" and "-" rocker button
only)
•
Response Speed, TEACH Selection, Offset Percent, Auto
Thresholds, Delays/Timers, Display Readout, Gain
Selection, Factory Defaults (from top panel or remote input)
•
Top panel interface lockout (from remote input only)
Factory Default Settings:
Setting
Factory Default
Threshold
2011
TEACH Selection
Two-Point TEACH
Response Speed
Standard: 250 µs
Offset Percent
10%
Auto Thresholds
OFF
OFF Delay
0 (Disabled)
OFF One-Shot
0 (Disabled)
ON Delay
0 (Disabled)
ON One-Shot
0 (Disabled)
Display Readout
Numeric, ECO disabled, Normal
Orientation
Gain Selection
Auto Gain
Indicators
Red 4-digit Display: Signal Level
Green 4-digit Display: Threshold
(In Program Mode, Red and Green displays are used for programming
menus)
Yellow LED: Output conducting
Construction
Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear
polycarbonate cover
Connections
PVC-jacketed 2 m or 9 m (6.5 ft. or 30 ft.) 4-wire integral cable; or
integral 4-pin M8 quick disconnect; or 150 mm (6 in.) cable with a 4pin M12 quick disconnect; or 150 mm (6 in.) cable with a 4-pin M8
quick disconnect.
Environmental Rating
IP50, NEMA 1
Operating Conditions
Temperature: –10 °C to +55 °C (+14 °F to +131 °F)
Storage Temperature: –20 °C to +85 °C (–4 °F to +185 °F)
Humidity: 90% at +60 °C maximum relative humidity (noncondensing)
Certifications
www.bannerengineering.com - Tel: + 1 888 373 6767
Industrial
Control
Equipment
3TJJ
23
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
4.1 Excess Gain Curves
The excess gain curves shown are for the standard red LED emitter models. Multiplication factors for the other colored LEDs
(with respect to the red LED values) are:
• White 0.5
• Green 0.6
• Blue 0.7
• IR850—see IR850 excess gain curves
The data in the charts that is labeled for the Long Range application apply to both the 1000 µs and 2000 µs response
speeds.
Figure 12. PIT16U-Opposed Mode
Long
Medium
Standard
Fast
High
Super High
1000
100
EXCESS GAIN
1000
10000
EXCESS GAIN
Figure 13. PBT16U-Diffuse Mode
Long
Medium
Standard
Fast
High
Super High
100
10
10
1
1
0.1
1
10
0.1
100
1
100
Figure 15. PBT26U-Diffuse Mode
Figure 14. PIT26U-Opposed Mode
10000
Long
Medium
Standard
Fast
High
Super High
10000
1000
100
Long
Medium
Standard
Fast
High
Super High
1000
EXCESS GAIN
100000
EXCESS GAIN
10
DISTANCE (mm)
DISTANCE (mm)
100
10
10
1
0.1
1
1
10
100
1000
0.1
DISTANCE (mm)
24
www.bannerengineering.com - Tel: + 1 888 373 6767
1
10
DISTANCE (mm)
100
1000
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
Figure 16. PIT46U-Opposed Mode
Figure 17. PBT46U-Diffuse Mode
1000000
100000
EXCESS GAIN
100000
10000
1000
100
Long
Medium
Standard
Fast
High
Super High
10000
EXCESS GAIN
Long
Medium
Standard
Fast
High
Super High
1000
100
10
10
1
0.1
1
1
10
100
1000
10000
1
Figure 18. PIT66U-Opposed Mode
100000
EXCESS GAIN
1000
10000
1000
100
Long
Medium
Standard
Fast
High
Super High
10000
EXCESS GAIN
Long
Medium
Standard
Fast
High
Super High
100000
1000
100
10
10
1
0.1
1
1
10
100
1000
10000
1
10
100
1000
DISTANCE (mm)
DISTANCE (mm)
Figure 21. IR850-Diffuse Mode
Figure 20. IR850-Opposed Mode
10000
Long
Medium
Standard
Fast
High
Super High
1000
100
10
Long
Medium
Standard
Fast
High
Super High
1000
EXCESS GAIN
10000
EXCESS GAIN
100
Figure 19. PBT66U-Diffuse Mode
1000000
1
10
DISTANCE (mm)
DISTANCE (mm)
100
10
10
100
1000
10000
1
1
DISTANCE (mm)
10
100
1000
DISTANCE (mm)
Note: IT.83.3ST5M6 glass fiber used for
opposed mode
Note: BTC1.13.4ST5M6 glass fiber used
for diffuse mode
www.bannerengineering.com - Tel: + 1 888 373 6767
25
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
4.2 Beam Patterns
The beam patterns shown are for the standard red LED emitter models. Multiplication factors for the other colored LEDs (with
respect to the red LED values) are:
• White 0.5
• Green 0.6
• Blue 0.7
• IR850—see the IR850 beam patterns
The data in the charts that is labeled for the Long Range application apply to both the 1000 µs and 2000 µs response
speeds.
Figure 22. PIT16U-Opposed Mode
Figure 23. PBT16U-Diffuse Mode
4
60
BEAM WIDTH (mm)
40
20
0
-20
Long
Medium
Standard
Fast
High
Super High
3
BEAM WIDTH (mm)
Long
Medium
Standard
Fast
High
Super High
2
1
0
-1
-2
-40
-3
-60
0
20
40
60
80
-4
100
0
5
10
DISTANCE (mm)
Figure 24. PIT26U-Opposed Mode
20
25
Figure 25. PBT26U-Diffuse Mode
30
400
200
100
0
-100
Long
Medium
Standard
Fast
High
Super High
20
BEAM WIDTH (mm)
Long
Medium
Standard
Fast
High
Super High
300
BEAM WIDTH (mm)
15
DISTANCE (mm)
10
0
-10
-200
-20
-300
-30
-400
0
50
100
150
200
DISTANCE (mm)
26
250
300
350
0
20
40
60
80
100
DISTANCE (mm)
www.bannerengineering.com - Tel: + 1 888 373 6767
120
140
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
Figure 27. PBT46U-Diffuse Mode
Figure 26. PIT46U-Opposed Mode
100
1200
80
Long
Medium
Standard
Fast
High
Super High
600
300
0
-300
Long
Medium
Standard
Fast
High
Super High
60
BEAM WIDTH (mm)
BEAM WIDTH (mm)
900
40
20
0
-20
-40
-600
-60
-900
-80
-1200
0
200
400
600
800
1000
-100
1200
0
100
DISTANCE (mm)
Figure 28. PIT66U-Opposed Mode
300
400
500
Figure 29. PBT66U-Diffuse Mode
2000
200
1600
800
400
0
-400
-800
150
BEAM WIDTH (mm)
Long
Medium
Standard
Fast
High
Super High
1200
BEAM WIDTH (mm)
200
DISTANCE (mm)
Long
Medium
Standard
Fast
High
Super High
100
50
0
-50
-100
-1200
-150
-1600
-200
-2000
0
500
1000
1500
2000
0
100
200
300
400
500
600
DISTANCE (mm)
DISTANCE (mm)
www.bannerengineering.com - Tel: + 1 888 373 6767
27
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
Figure 30. IR850-Opposed Mode
Figure 31. IR850-Diffuse Mode
1000
150
BEAM WIDTH (mm)
600
400
200
0
-200
-400
-600
Long
Medium
Standard
Fast
High
Super High
100
BEAM WIDTH (mm)
Long
Medium
Standard
Fast
High
Super High
800
50
0
-50
-100
-800
-150
-1000
0
500
1000
1500
2000
2500
0
100
200
DISTANCE (mm)
Note: IT.83.3ST5M6 glass fiber used for
opposed mode
400
500
600
700
Note: BTC1.13.4ST5M6 glass fiber used
for diffuse mode
4.3 Dimensions
28
300
DISTANCE (mm)
www.bannerengineering.com - Tel: + 1 888 373 6767
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
5 Accessories
SA-DIN-CLAMP
•
Pair of metal DIN rail end stops; slide onto DIN rail at either
side of the sensor stack
•
Combination (#2 Phillips, #8 standard slotted) set screw
DIN-35-..
35 mm DIN Rail
Model
Length
DIN-35-70
70
DIN-35-105
105
DIN-35-140
140
DIN-35-180
180
DIN-35-220
220
L
35
L = 70, 105 or 140 mm
9.1 mm
(0.63")
Hole center spacing: 35.1
Hole size: 25.4 x 5.3
9.1 mm
(0.36")
45.0 mm
(1.77")
SA-DIN-BRACKET
•
Plastic bracket with
mounting screws
10
SA-DIN-BRACKET-10
•
Package of 10 plastic
brackets with mounting
screws
10
35
35
Hole center spacing: A = 16, B = 25.4, C = 15.2
Hole center spacing: A = 16, B = 25.4, C = 15.2
Hole size: A = ø 3.2, B = ø 3.3, C = ø 4.4
Hole size: A = ø 3.2, B = ø 3.3, C = ø 4.4
5.1 Quick-Disconnect Cordsets
All measurements are listed in millimeters, unless noted otherwise.
4-Pin Threaded M12 Cordsets—Single Ended
Model
Length
MQDC-406
2 m (6.56 ft)
MQDC-415
5 m (16.4 ft)
MQDC-430
9 m (29.5 ft)
MQDC-450
15 m (49.2 ft)
MQDC-406RA
2 m (6.56 ft)
MQDC-415RA
5 m (16.4 ft)
MQDC-430RA
9 m (29.5 ft)
MQDC-450RA
15 m (49.2 ft)
Style
Dimensions
Pinout (Female)
44 Typ.
1
Straight
M12 x 1
ø 14.5
2
3
4
1 = Brown
2 = White
32 Typ.
[1.26"]
2
30 Typ.
[1.18"]
Right-Angle
1
3 = Blue
3
4 = Black
4
M12 x 1
ø 14.5 [0.57"]
www.bannerengineering.com - Tel: + 1 888 373 6767
29
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
4-Pin Threaded M8 Cordsets—Single Ended
Model
Length
PKG4M-2
2.04 m (6.68
ft)
PKG4M-5
5 m (16.4 ft)
PKG4M-9
9.04 m (29.6
ft)
PKW4M-2
2 m (6.56 ft)
PKW4M-5
5 m (16.4 ft)
Style
Dimensions
35 Typ.
Straight
4
ø 9.5
2
1
3
M8 x 1
28 Typ.
20 Typ.
Right Angle
PKW4M-9
Pinout (Female)
9 m (29.5 ft)
4
2
3
1
1 = Brown
2 = White
3 = Blue
4 = Black
M8 x 1
ø 9.5
4-Pin Snap-on M8 Cordsets—Single Ended
Model
Length
PKG4-2
2.03 m (6.66
ft)
PKG4-5
5.03 m (16.5
ft)
PKG4-10
10 m (32.9 ft)
PKW4Z-2
2 m (6.56 ft)
Style
Dimensions
Pinout (Female)
32 Typ.
4
Straight
ø 9.0
2
1
3
1 = Brown
4
29 Typ.
3
Right-Angle
PKW4Z-5
15 Typ.
5 m (16.4 ft)
ø 10.9
30
www.bannerengineering.com - Tel: + 1 888 373 6767
2
2 = White
1
4 = Black
3 = Blue
DF-G2 High Speed Expert™ Dual Display Fiber Amplifier
6 Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will
repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This
warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF
DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE
LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER
ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product
previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection
applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by
Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product
specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most
recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.
www.bannerengineering.com - Tel: + 1 888 373 6767
31