0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
8B41-07

8B41-07

  • 厂商:

    DATAFORTH(Dataforth)

  • 封装:

    -

  • 描述:

    VOLTAGE INPUT MODULE, 1KHZ BW

  • 数据手册
  • 价格&库存
8B41-07 数据手册
SensorLex® 8BIsolated IsolatedAnalog AnalogSignal SignalConditioning ConditioningProducts Products S C 8MB 5 B 8B40/41 Voltage Input Modules, 1kHz Bandwidth Description 8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. ach B or B module isolates, filters, and amplifies a voltage input signal and provides an analog voltage output (Figure 1). Signal filtering is accomplished with a pole filter optimi ed for time and frequency response which provides 100dB per decade of normal-mode re ection above H . One pole of this filter is on the field side of the isolation barrier for anti aliasing, and the other four are on the system side. A special input circuit on the 8B40 and 8B41 modules provides protection against accidental connection of power-line voltages up to 240VAC. Clamp circuits on the I/O and power terminals protect against harmful transients. Isolation is provided by transformer coupling to suppress transmission of common mode spikes or surges. The module is powered from +5VDC, ± 5% . The modules are designed for installation in Class I, Division 2 hazardous locations and have a high level of immunity to environmental noise. Features • Accepts Millivolt and Voltage Level Signals • High-Level Voltage Outputs • 1500Vrms Isolation • ANSI/IEEE C37.90.1 Transient Protection • Input Protection to 240VAC Continuous • 100dB CMR • 1kHz Signal Bandwidth • ± 0.05% Accuracy • ± 0.02% Linearity Low Drift with Ambient Temperature • C-UL-US Listed • CE Compliant • ATEX Compliance Pending • Mix and Match Module Types on Backpanel F i g u r e 1 : 8 B 4 0 / 4 1 B l o ck D ia g r a m 1 2 2 ©1995-2017 Dataforth Corporation, All Rights Reserved For information call 800-444-7644 ISO9001:2008-Registered QMS SensorLex® 8B Isolated Analog Signal Conditioning Products Typical❇ at TA Module Input Range Input Bias Current Input Resistance Normal Power Off Overload Input Protection Continuous(1) Transient CMV, Input to Output Transient, Input to Output CMR (50Hz or 60Hz) NMR (-3dB at 1kHz) Accuracy(2) Linearity Stability Offset Gain Noise Output, 100kHz Bandwidth, – 3dB Response Time, 90% Span Output Range Output Protection Transient Power Supply Voltage Power Supply Current Power Supply Sensitivity Mechanical Dimensions (h)(w)(d) Environmental Operating Temp. Range Storage Temp. Range Relative Humidity Emissions EN61000-6-4 Radiated, Conducted Immunity EN61000-6-2 RF ESD, EFT and Ordering Information D power 8B40 8B41 ± 10mV to ± 100mV ± 0.5nA ± 1V to ± 60V ± 0.05nA Model minimum minimum minimum * 240VAC ANSI/IEEE C37.90.1 * 1500Vrms max ANSI/IEEE C37.90.1 100dB dB per Decade above H * * * * ± 0.05% Span ± 0.02% Span * ppm ppm * ppm * * rms 1kHz s Input Range Output Range 8B40-01 8B40-02 8B40-03 8B40-04 8B40-05 8B40-06 – 10mV to +10mV – 50mV to +50mV – 100mV to +100mV – 10mV to +10mV – 50mV to +50mV – 100mV to +100mV – 5V to +5V – 5V to +5V – 5V to +5V 0 to +5V 0 to +5V 0 to +5V 8B41-01 8B41-02 8B41-03 8B41-04 8B41-05 8B41-06 8B41-07 8B41-08 8B41-09 8B41-10 8B41-12 8B41-13 – 1V to +1V – 5V to +5V 10V to +10V – 1V to +1V – 5V to +5V 10V to +10V 20V to +20V 20V to +20V 40V to +40V 40V to +40V 60V to +60V 60V to +60V – 5V to +5V – 5V to +5V – 5V to +5V 0V to +5V 0V to +5V 0V to +5V – 5V to +5V 0V to +5V – 5V to +5V 0V to +5V – 5V to +5V 0V to +5V – – – – – – – – 8 B Specifications 8 B * * See Ordering Information Continuous Short to Ground ANSI/IEEE C37.90.1 * * * +5VDC ± 5% 25mA ± 75ppm/% * * 1.11” x 1.65” x 0.40” (28.1mm x 41.9mm x 10.2mm) * to to 0 to 95% Noncondensing ISM, Group 1 Class A ISM, Group 1 Performance A ± 0.5% Span Error Performance B * * * * * * * * * NOTES: ❇ ontact factory or your local Dataforth sales office for maximum values. Same specification as B . A between Input terminal and Input, , or terminals. A between Input and or terminals. A between and terminals. Includes linearity, hysteresis and repeatability. Installation Notes: . This uipment is Suitable for se in lass I, Division , Groups A, B, , D, or Non-Hazardous Locations Only. . ARNING xplosion Ha ard Substitution of Any omponents ay Impair Suitability for lass I, Division . 3.) WARNING - Explosion Hazard - Do Not Disconnect Equipment Unless Power Has Been Switched Off or The Area is nown to be Non Ha ardous. Visit our website www.dataforth.com ©1995-2017 Dataforth Corporation, All Rights Reserved 1 2 3 ISO9001:2008-Registered QMS
8B41-07 价格&库存

很抱歉,暂时无法提供与“8B41-07”相匹配的价格&库存,您可以联系我们找货

免费人工找货