SensorLex® 8BIsolated
IsolatedAnalog
AnalogSignal
SignalConditioning
ConditioningProducts
Products
S C 8MB 5 B
8B30/31
Voltage Input Modules, Narrow Bandwidth
Description
8B modules are an optimal solution for monitoring real-world process
signals and providing high-level signals to a data acquisition system.
ach B or B module isolates, filters, and amplifies a voltage input
signal and provides an analog voltage output (Figure 1).
Signal filtering is accomplished with a pole filter optimi ed for time and
frequency response which provides 70dB of normal-mode rejection at
H . One pole of this filter is on the field side of the isolation barrier for
anti-aliasing, and the other four are on the system side.
A special input circuit on the 8B30 and 8B31 modules provides
protection against accidental connection of power-line voltages up to
240VAC. Clamp circuits on the I/O and power terminals protect against
harmful transients.
Isolation is provided by transformer coupling to suppress transmission
of common mode spikes or surges. The module is powered from
+5VDC, ± 5% .
The modules are designed for installation in Class I, Division 2 hazardous
locations and have a high level of immunity to environmental noise.
Features
• Accepts Millivolt and Voltage Level Signals
• High-Level Voltage Outputs
• 1500Vrms Isolation
• ANSI/IEEE C37.90.1 Transient Protection
• Input Protection to 240VAC Continuous
• 120dB CMR
• 70dB NMR at 60Hz
• ± 0.05% Accuracy
• ± 0.02% Linearity
Low Drift with Ambient Temperature
• C-UL-US Listed
• CE Compliant
• ATEX Compliance Pending
• Mix and Match Module Types on Backpanel
Iso-Chopper™
Amplifier
Pat. Pending
F i g u r e 1 : 8 B 3 0 / 3 1 B l o ck
D ia g r a m
1 0 4
©1995-2017 Dataforth Corporation, All Rights Reserved
For information call 800-444-7644
ISO9001:2008-Registered QMS
SensorLex® 8B Isolated Analog Signal Conditioning Products
Typical❇ at TA
Module
and
Ordering Information
D power
8B31
± 1V to ± 60V
± 0.05nA
240VAC
ANSI/IEEE C37.90.1
240VAC
*
CMV, Input to Output
Transient, Input to Output
CMR (50Hz or 60Hz)
NMR
1500Vrms max
ANSI/IEEE C37.90.1
120dB
70dB at 60Hz
*
Accuracy(2)
Linearity
Stability
Offset
Gain
Noise
Output, 100kHz
Bandwidth, – 3dB
Response Time, 90% Span
Output Range
Output Protection
Transient
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
Mechanical Dimensions
(h)(w)(d)
Environmental
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Emissions EN61000-6-4
Radiated, Conducted
Immunity EN61000-6-2
RF
ESD,EFT
Model
8B30
± 10mV to ± 100mV
± 0.5nA
Input Range
Input Bias Current
Input Resistance
Normal
Power Off
Overload
Input Protection
Continuous(1)
Transient
minimum
minimum
minimum
*
*
*
± 0.05% Span
± 0.02% Span
*
ppm
ppm
*
ppm
rms
3Hz
160ms
*
*
Input Range
Output Range
8B30-01
8B30-02
8B30-03
8B30-04
8B30-05
8B30-06
– 10mV to +10mV
– 50mV to +50mV
– 100mV to +100mV
– 10mV to +10mV
– 50mV to +50mV
– 100mV to +100mV
– 5V to +5V
– 5V to +5V
– 5V to +5V
0V to +5V
0V to +5V
0V to +5V
8B31-01
8B31-02
8B31-03
8B31-04
8B31-05
8B31-06
8B31-07
8B31-08
8B31-09
8B31-10
8B31-12
8B31-13
– 1V to +1V
– 5V to +5V
10V to +10V
– 1V to +1V
– 5V to +5V
10V to +10V
20V to +20V
20V to +20V
40V to +40V
40V to +40V
60V to +60V
60V to +60V
– 5V to +5V
– 5V to +5V
– 5V to +5V
0V to +5V
0V to +5V
0V to +5V
– 5V to +5V
0V to +5V
– 5V to +5V
0V to +5V
– 5V to +5V
0V to +5V
–
–
–
–
–
–
–
–
8 B
Specifications
8 B
*
See Ordering Information
Continuous Short to Ground
ANSI/IEEE C37.90.1
*
*
*
*
+5VDC ± 5%
25mA
± 75ppm/%
*
*
*
to
to
0 to 95% Noncondensing
ISM, Group 1
Class A
ISM, Group 1
Performance A ± 0.5% Span Error
Performance B
*
*
1.11” x 1.65” x 0.40”
(28.1mm x 41.9mm x 10.2mm)
*
*
*
*
*
*
*
NOTES:
❇
ontact factory or your local Dataforth sales office for maximum values.
* Same specification as B .
A between Input terminal and Input,
, or
terminals.
A between Input and
or
terminals.
A between
and
terminals.
Includes linearity, hysteresis and repeatability.
Installation Notes:
. This uipment is Suitable for se in lass I, Division , Groups A, B, , D,
or Non-Hazardous Locations Only.
.
ARNING xplosion Ha ard Substitution of Any omponents ay Impair
Suitability for lass I, Division .
3.) WARNING - Explosion Hazard - Do Not Disconnect Equipment Unless
Power Has Been Switched Off or The Area is nown to be Non Ha ardous.
Visit our website www.dataforth.com
©1995-2017 Dataforth Corporation, All Rights Reserved
1 0 5
ISO9001:2008-Registered QMS
很抱歉,暂时无法提供与“8B31-08”相匹配的价格&库存,您可以联系我们找货
免费人工找货