Surge arrester
3-Electrode arrester
Series/Type:
DG3R470L
Customer:
Version/Date:
Issue 01/2013-4-7
DC Elec. 2017 . Reproduction,publication and dissemination of this document, enclosures here to and the
information contained therein without DC' prior express consent is prohibited.
Surge arrester
3-Electrode arrester
DG3R470L
Features
Applications
●
Extremely small size
● Splitter
●
Extremely fast response time
● PCI Cards
●
Stable performance over life
● Morden
●
Very low capacitance
● Line Cards
●
High insulation resistance
●
RoHS-compatible
●
UL-identification:E311500
Electrical specifications
DC breakdown voltage 1)2)
Tolerance
Impulse breakdown voltage
at 1kv/μs
–For 99% measure values
Service life
10 operations
8/20us
10 operations
50Hz,1S
150 operations
10/1000us
Insulation resistance at DC100V
Capacitance at 1MHz
Weight
Storage and operations temperature
Climatic category(IEC60068-1)
Marking,Blue positive
470
±20
V
%
≤1000
V
10
10
200
≥1
≤2
1.5
-40…+90
40/90/21
DG3R470L
KA
A
A
GΩ
pF
g
°C
www.jsdgme.com
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 01/2013-4-7
Page 2 of 4
Surge arrester
3-Electrode arrester
DG3R470L
DC breakdown voltage
8/20us, Test wave
10/700us,Test Wave
10/1000us,Test Wave
T1=1.25T=8us±20%
T1=1.67T=10us±20%
T1=1.67T=10us±20%
T2=20us±20%
T2=700us±20%
T2=1000us±20%
Recommended wave slodering profile
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 01/2013-4-7
Page 3 of 4
Surge arrester
3-Electrode arrester
1)
2)
3)
Sampling size in accordance to AQL(C=0)
In ionized mode
Tests according to ITU-T Rec. K. 12 IEC61663-2 and IEC61643-311
DG3R470L
Dimensions
Cautions and warnings
Surge arresters must not be operated directly in power supply networks,whose maximum operating voltage
exceeds the minimum spark-over voltage of the surge arresters.
●
●
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
●
If the contacts of the surge arrester are defective, current stress can lead to the formation of sparks and loud noises.
Surge arresters may be used only within their specified values. In case of overload, the head contacts may
fail or the component may be destroyed.
●
●
Damaged surge arresters must not be re-used.
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 01/2013-4-7
Page 4 of 4
很抱歉,暂时无法提供与“DG3R470L”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+2.61360
- 10+2.07360
- 30+1.84680
- 100+1.55520
- 500+1.43640
- 1000+1.36080