USER MANUAL V1.0
ECT 300 Perpetuum Kit
Ultra Low Voltage DC/DC Converter
for Thermal Energy Harvesting
Covered by at least following patents:
W098/36395 | DE 10025561 | DE 10062028 | DE 10150128
DE 10155125 | DE 10063305 | DE 10301678 | DE29712270.3
W O00/043802 | DE 202004005837.5 | EP 1389358 | US 7,005,778 B2
EP 1550202 | US 7,019,241 B2 | DE 10256942.8 | DE 10256942.8 |
DE 10256940 | DE 10315765 | DE 10315765
Further patents pending:
http://www.enocean.com/en/patents/
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modification
EDK 300 User Manual
November 6, 2009 5:03 PM
Page 1/8
USER MANUAL
ECT 300 PERPETUUM KIT
REVISION HISTORY
The following major modifications and improvements have been made to the first version of this
document:
No
1.0
1.3
Major Changes
Initial version
Updated MK
Published by EnOcean GmbH, Kolpingring 18a, 82041 Oberhaching, Germany
www.enocean.com, info@enocean.com, phone +49 (89) 6734 6890
© EnOcean GmbH, All Rights Reserved
Important notes!
This information describes the type of component and shall not be considered as assured characteristics. No responsibility is assumed for possible omissions or inaccuracies. Circuitry and specifications
are subject to change without notice. For the latest product specifications, refer to the EnOcean website: http://www.enocean.com.
As far as patents or other rights of third parties are concerned, liability is only assumed for modules,
not for the described applications, processes and circuits.
EnOcean does not assume responsibility for use of modules described and limits its liability to the
replacement of modules determined to be defective due to workmanship. Devices or systems containing RF components must meet the essential requirements of the local legal authorities.
The modules must not be used in any relation with equipment that supports, directly or indirectly,
human health or life or with applications that can result in danger for people, animals or real value.
Components of the modules are considered and should be disposed of as hazardous waste. Local
government regulations are to be observed.
Packing: Please use the recycling operators known to you. By agreement we will take packing material back if it is sorted. You must bear the costs of transport. For packing material that is returned to
us unsorted or that we are not obliged to accept, we shall have to invoice you for any costs incurred.
This evaluation kit and its components are intended for use for evaluation, demonstration
or engineering development purposes only. It is not considered to be a finished end product fit
for consumer use. Persons handling this developer kit must have electronics expertise and observe
good engineering practice standards. As such, the goods being provided are not intended to be complete in terms of required design, marketing, and/or manufacturing related protective considerations,
including product safety and environmental measures typically found in end products that incorporate
such electronic components or circuit board. EnOcean does not reliable consequences for any HW or
SW changes/modifications of the developer board done by the developer.
Observe precautions! Electrostatic sensitive devices!
© 2009 EnOcean | www.enocean.com
}
EDK300 / EDK300C User Manual | Page 2/8
USER MANUAL
ECT 300 PERPETUUM KIT
TABLE OF CONTENT
1
General Description .......................................................................................4
2
Content and ordering information ....................................................................4
3
Technical Data ..............................................................................................5
4
Usage with EnOcean’s EDK 300(C) ..................................................................7
© 2009 EnOcean | www.enocean.com
}
EDK300 / EDK300C User Manual | Page 3/8
USER MANUAL
ECT 300 PERPETUUM KIT
1
General Description
Basic Functionality
ECT 300 Perpetuum Kit is intended to evaluate EnOcean’s latest thermal energy harvester
solution. ECT 300 is able to power wireless sensor nodes from only a few Kelvin temperature differentials.
ECT 300 is based on a revolutionary ultra low voltage DC/DC converter which automatically
starts operation at about 20mV input voltage. Output power depends on the actual temperature difference between both sides of the Peltier element and the Peltier element being
used.
ECT 300 Perpetuum Kit is designed as accessory for EnOcean’s self-powered sensor developer kit EDK 300. In combination with this kit a complete thermal powered radio sensor
application can be evaluated and programmed.
Typical application:
A typical thermo-driven sensor consists of a sensor element (e.g. temperature sensor), a
small Peltier element, a heat sink, the new DC/DC converter and a radio module (e.g.
STM300). Powered by the temperature differential STM 300 will wake up on a regular basis,
e.g. every 10s, acquire sensor values and transmit them via a radio signal over a distance
of up to 300m. Typical application areas are home and building automation, automated
meter reading, and condition monitoring.
Heat sink
ECT 300
DC/DC
Peltier
2
Sensor +
EnOcean
Radio
Modul
Content and ordering information
1x ECT 300 modul
1x Peltier element with heat sink
1x Peltier element w/o heat sink
1x Thermal compound
Type
ECT 300 Perpetuum Kit
© 2009 EnOcean | www.enocean.com
}
Ultra Low Voltage DC/DC Converter (Engineering Sample)
TEC2L-15-15-5.6/73CS combined with
SK 426 (Fischer Elektronik)
TEC2L-15-15-5.6/73CS (EURECA)
WLP 004 (Fischer Elektronik)
Ordering Code
S3004-P300
Frequency
-
EDK300 / EDK300C User Manual | Page 4/8
USER MANUAL
ECT 300 PERPETUUM KIT
3
Technical Data
ECT 300 DC/DC converter module
Physical dimensions
Typical supply voltage VIN
Max. supply voltage VIN
Typical source impedance
Typical output voltage VOUT
Average efficiency
20x12x5mm
0.02V – 0.50V
1.0V
< 2Ohm
3.4V
~30%
ECT 300 Dimensions and pin out
12 mm
9 8 7 6 5 4 3 2 1
8 x 2.00 mm
5 mm
20 mm
Pin
1
2
3
4
5
6
7
8
9
Name
VIN1
NC
NC
VIN2
VOutAC
NC
VOUT
NC
GND
Description
Voltage input 1. External generator connected to this pin
Not connected
Not connected
Voltage input 2. External generator connected to this pin
AC output (for internal use only)
Not connected
Output voltage of the power converter module
Not connected
Ground
© 2009 EnOcean | www.enocean.com
}
EDK300 / EDK300C User Manual | Page 5/8
USER MANUAL
ECT 300 PERPETUUM KIT
Following diagram shows a typical ECT 300 performance in combination with Peltier element (TEC2L-15-15-5.6) and heat sink (SK 426). Performance will be affected by variance
of components and environment (air flow etc.).
ECT100perpetuum Stepcode: BA
1400
1200
Pout / uW
1000
800
600
inferior
heat sink
400
200
0
0
5
10
15
20
25
de lta T / K
Peltier Element
Type
Temperature coefficient
Internal resistance
Thermal conductivity
Eureca TEC2L-15-15-5.6/73CS
12.5 mV/K
1.44 Ω
0.046 W/K
Heat Sink
Type
Thermal resistance
© 2009 EnOcean | www.enocean.com
}
SK 426, 50mm
4.5 K/W
EDK300 / EDK300C User Manual | Page 6/8
USER MANUAL
ECT 300 PERPETUUM KIT
4
Usage with EnOcean’s EDK 300(C)
1. Configure EVA 320 according to following application example
- Temperature sensor: NTC on ADIO0
- Retransmit: every
- Wakeup: 1s
- Long term storage: EXT. (None)
- Power Converter: ECT 300 plugged
- Source: External source (Peltier connected)
- Power Management: Off (On board)
Peltier
ECT 300
If heat sink has room temperature (e.g. 20°C) and you press one finger on the Peltier
element above, the element will generate a few mV. ECT 300 will transform this to
higher voltage and load short term capacitor on EVA 320. STM 300 will be powered by
this energy and send telegrams.
© 2009 EnOcean | www.enocean.com
}
EDK300 / EDK300C User Manual | Page 7/8
USER MANUAL
ECT 300 PERPETUUM KIT
2. Check ECT 300 output voltage via voltmeter
In order to see ramp up of CT 300 output voltage you can measure this between
VDDLIM and GND. Since there is no long term storage connected (in this example) it
will take some seconds until supply voltage is high enough and STM 300 will send
telegrams.
Voltmeter
Peltier
ECT 300
© 2009 EnOcean | www.enocean.com
}
EDK300 / EDK300C User Manual | Page 8/8
很抱歉,暂时无法提供与“ECT300KIT”相匹配的价格&库存,您可以联系我们找货