TIMERS
TIMERS
GENERAL DETAILS
OF TYPE S TIMERS
S series are compact, low cost, precision devices designed to the most
demanding specifications. The small size, epoxy filled case is highly resistant
against dust, vibrations, shock or humidity. Creep and strike distance according
to VDE 0110 Group C 250V. Case protection IP66. Case material - Polymid.
1.96
(50)
0.47
(12)
0.8
2.46
(62.5)
0.77
(45)
0.16
(42)
0.69
(17.5)
6.35
2.76
(70)
2.36
(60)
2
SAS
SERIES
DELAY ON MAKE
Function A:
Delay on Make
Input Power S1
TIMER WITH SOLID
STATE OUTPUT
UL listed
Output
0
T
CSA recognized
SPECIFICATIONS:
Input Power . . . . . . . . . . . . . . . . . . 24 VAC/DC, 110 VAC/DC
220 VAC/DC, ±15%, 50/60 Hz
Output Rating . . . . . . . . . . . . . . . . max.: 1.0 A at 20°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . min.: 10 mA
Repetition accuracy . . . . . . . . . . . ±0.5% at a constant ambient
Temp rise derating . . . . . . . . . . . . 5 mA / °C
Reset time SAS-L & SAS-DL . . . . . . . 25 ms after timing
100 ms during timing
SAS-PL. . . . . . . . . . . . . 100 ms during timing
Leakage current during timing . . . 5 mA max
Peak surge current . . . . . . . . . . . . 20 A < 10 ms
Peak surge voltage . . . . . . . . . . . . 1400 V, 10 µs
Terminals . . . . . . . . . . . . . . . . . . . . 1/4˝ (6.35mm) quick connect
Opertating temperature . . . . . . . . . -22°F to +140°F (-30°C to +60°C)
Weight . . . . . . . . . . . . . . . . . . . . . . 1.9 oz. (55g)
Function A: When input power is applied, timing (t) begins. At the end
of the preselected time, the solid state SCR output turns on. The output turns off when the input power is removed, resetting the timer for
the next cycle.
WIRING DIAGRAM:
+-
SAS
˜
SAS-D
S1
SAS-P
S1
S1
470K
POTENTIOMETER
A1 A2
Peak Surge Current
A1 A2 Z1 Z2
A1 A2
100A
50A
20A
15A
10A
Peak Surge Current vs Surge Current Duration
LOAD
5A
LOAD
LOAD
2A
1A
10ms 20ms 50ms 100ms 200ms 500ms
1s 2s 5s
+-
Surge Current Duration
ORDERING INFORMATION: (100 pcs. minimum order)
˜
S
AS-D
100S
220 AD
MOUNTING
SERIES
TIME RANGE
INPUT POWER
S=Encapsulated requiring
DIN-Rail, Panel Adapter
or use Base Mounting
Holes
AS = standard relay
AS-D = remote potentiometer
AS-P = internal potentiometer
AS = Fixed .1 sec - 1 min
AS-D = .1 sec - 60 min
Ex = 10-100 sec maintain 10:1 ratio
AS-P = .1 sec - 10 sec
1-100 sec maintain 100:1 ratio
24AD = 24 VAC/DC
110AD = 110 VAC/DC
220AD = 220 VAC/DC
L
UL
1 AMP
Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
2/43
TIMERS
TIMERS
SDS
SERIES
REPEAT CYCLE TIMER
UL listed
CSA recognized
• Shock Resistant
• SCR Solid State Output
• Optional Remote Potentiometer
• DIN-Rail or Base Mounting
When input power S1 is applied, the solid state output turns on
immediately for the timer period specified. It then turns OFF for that
same time period and repeats continuously while power is applied.
Recycling
Input Power S1
Output
0
T
T
t
SPECIFICATIONS:
WIRING DIAGRAM:
Input
. . . . . . . . . . . . . . . . . . . . . . 24 VAC, 48 VAC, 110 VAC
220 VAC, ±15%, 50/60 Hz
Maximum power consumption . . 24 VAC: 0.2 VA
48 VAC: 0.3 VA
110 VAC: 0.6 VA
220 VAC: 1.2 VA
Output . . . . . . . . . . . . . . . . . . . . . SCR
Output Rating . . . . . . . . . . . . . . . max.: 1.0 A at 20°C
min.: 10 mA
Repetition accuracy . . . . . . . . . . ±0.5% at a constant ambient
Temp. rise derating . . . . . . . . . . . 5 mA / °C
Reset time . . . . . . . . . . . . . . . . . . 100 ms after timing
150 ms during timing
Leakage current during timing . . 2 mA max.
Peak surge current . . . . . . . . . . . 20 A < 10ms
Peak surge voltage . . . . . . . . . . . 1400 V, 100 µs
Terminals . . . . . . . . . . . . . . . . . . . Faston 1/4˝ (6.35mm)
Operating temperature . . . . . . . . -22°F to +140°F -30°C to +60°C
Weight . . . . . . . . . . . . . . . . . . . . . 1.9 oz. (55g)
SDS
S1
SDSD
SDSP
S1
470 K
S1
POTENTIOMETER
A2 18 A1
A2 18 A1 Z1 Z2
LOAD
A2 18 A1
LOAD
LOAD
DIMENSIONS See page 3-34
ORDERING INFORMATION: (100 pcs. minimum order)
P.S.: Specify maximum time for “D” and “P” versions.
S
DS
10 min
24
MOUNTING
SERIES
TIME RANGE
INPUT POWER
S = Encapsulated, requiring
DIN-Rail, Panel Adapter or
use Base Mounting Holes
DS = Fixed time
DS-D = remote potentiometer
DS-P = internal potentiometer
DS = Fixed .1s. - 120 min
DS-D = .1 sec. - 120 min.
Maintain 10:1 ratio
DS-P = 1 -10 sec. or min., 10 - 100 sec. or min.
Maintain 100:1 ratio
24A = 24 VAC
48A= 48 VAC
110A = 110 VAC
220A = 220 VAC
Products and specifications subject to change without notice.
2/44
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
L
UL
1 AMP
TIMERS
TIMERS
SHS
SERIES
INTERVAL TIMER WITH
SOLID STATE OUTPUT
UL listed
CSA recognized
• Epoxy Encapsulated
• DIN-Rail or Base Mounting
• Internal or External Time Set
• Fixed Time
2
The solid state output turns on when the input power (S1) is
applied. The output turns off at the end of time (T). The timer is
reset when the input power is removed.
Function H:
Internal Timer
Input Power S1
Output
T
0
t
SPECIFICATIONS:
WIRING DIAGRAM:
Input . . . . . . . . . . . . . . . . . . . . . . 24 VAC, 48 VAC, 110 VAC
220 VAC, ±15%, 50/60 Hz
Maximum power consumption . . 24 VAC: 0.2 VA
48 VAC: 0.3 VA
110 VAC: 0.6 VA
220 VAC: 1.2 VA
Output . . . . . . . . . . . . . . . . . . . . . SCR
Output Rating . . . . . . . . . . . . . . . max.: 1.0 A at 20°C
min.: 10 mA
Repetition accuracy . . . . . . . . . . ±0.5% at a constant ambient
Temp. rise derating . . . . . . . . . . . 5 mA / °C
Reset time . . . . . . . . . . . . . . . . . . 100 ms after timing
150 ms during timing
Leakage current during timing . 2 mA max.
Peak surge current . . . . . . . . . . . 20 A < 10 ms
Peak surge voltage . . . . . . . . . . . 1400 V, 100 µs
Terminals . . . . . . . . . . . . . . . . . . Faston 1/4˝ (6.35mm)
Operating temperature . . . . . . . . -22°F to +140°F
-30°C to +60°C
Weight . . . . . . . . . . . . . . . . . . . . . 1.9 oz. (55g)
SHS
S1
SHS-D
SHS-P
S1
470 K
S1
POTENTIOMETER
A2 18 A1
A2 18 A1 Z1 Z2
LOAD
A2 18 A1
LOAD
LOAD
Note: Available with internal potentiometer in HS-P Series.
ORDERING INFORMATION: (100 pcs. minimum order)
DIMENSIONS See page 3-34
P.S.: Specify maximum time for “D” and “P” versions.
S
HS-D
MOUNTING
SERIES
S = Encapsulated, requiring
DIN-Rail, Panel
Adapter or Base Mounting
Holes
HS = Fixed time
HS-D = remote potentiometer
HS-P = internal potentiometer
300S
TIME RANGE
HS = Fixed .1s. - 120 min
HS-D =.1 sec. - 120 min. Maintain 10:1 ratio
HS-P =1-10 sec. or min., 10 - 100 sec. or min.
Maintain 100:1 ratio
220A
INPUT POWER
24A = 24 VAC
48A = 48 VAC
110A = 110 VAC
220A = 220 VAC
L
UL
1 AMP
Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
2/45
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Crouzet:
SAS10M220AD SASP100M110AD SASP10M220AD SASP10S110AD SDS5S220A SHSP10M24A SHSP20M24A
SHSP30S24A SHS5S110A SHS15S110A SHSP20M220A SHS200S110A SHSP10S24A SHSP100S110A
SHSP15S110A SHS1S24A SHS180S24A SHS10M220A SHS3S110A SHS120S110A SHS13M220A SHS4S110A
SHSP20M110A SHS21M110A SHS1S110A SHSP10M110A SHSP100M220A SHSP50S24A SHSP15M24A
SHS100S110A SHSP100M110A SHS10S110A SHS5M110A SHS20S110A SHSP5S24A SHSP60S24A
SHSP6S110A SHSP10S220A SHSP300S24A SHS20S220A SHSP6M220A SHSP10S110A SHS3S24A
SHS15M110A SHSP1S110A SHSP20S24A SHSP60S110A SHSP4M24A SHSP15M110A SHS1M24A
SHS2.5S24A SHS60M110A SHS15S24A SHS2S110A SHSP600S110A SHSP8M110A SHS21M220A
SHSP2M24A SHSP10M220A SHS2.5S110A SHSP2S220A SHSP60M110A SHSP5S220A SHS180S110A
SHS90S110A SHS16M220A SHS20M220A SHSP100S24A SDS.5S220A SAS20S110AD SAS250S110AD
SAS2S110AD SAS2S220AD SAS2S24AD SAS300S110AD SAS300S24AD SAS30S110AD SAS30S24AD
SAS380S110A SAS3S110AD SAS3S12AD SAS3S220AD SAS45S24AD SAS4S110AD SAS4S220AD
SAS4S24AD SAS5S110AD SAS5S12AD SAS5S220AD SAS5S24AD SAS60S110A SAS60S24AD SAS6S110AD
SAS6S220A SAS7S110AD SAS7S220AD SAS8S220AD SAS90S110AD SASP1000S110A SASP1000S220AD
很抱歉,暂时无法提供与“SAS120S110AD”相匹配的价格&库存,您可以联系我们找货