83880112

83880112

  • 厂商:

    CROUZET(高诺斯)

  • 封装:

    -

  • 描述:

    检测开关 DC24V AC250V

  • 数据手册
  • 价格&库存
83880112 数据手册
Compact Limit Switches Series 83 880 IP 67 Conforms to the following standards IEC / EN 60947.5.1 Dimensional conformity: NFC 63145 Low voltage directive: 73/23/EEC and 93/68/EEC Electric shock protection: NFC 20030 or IEC 60536 class 1, degree of pollution 3. Temperature specification: –25°/+70°C –13°/+158°F Degree of protection According to IEC 62529: According to NEMA : IP 66 / 67 Type 1, 3, 4, 6, 13 Function Four-terminal double break contact element (form Zb) with positive opening NC contacts. The two moving contacts are electrically isolated from one another. Standard Plunger or roller at 90° Standard Part Number (Cable length = 2.0 meters, exit: side) Actuator Type Metal plunger Metal roller plunger Metal plunger with threaded barrel Roller plunger - metal with threaded barrel Metal roller lever (operates in both directions) Mechanical characteristics Minimum positive opening force Minimum total travel force Force d’ouverture positive minimum Mechanical life Weight Sequences Dimensions BK (4) mm See sequence diagram 83 880 Blue Black millions of operations g UL cables are 4 black wires numbered 1-4 with a GRN-YLW ground wire Zb (3) BU N (cmN) N (cmN) Positions: nominal data Principle Snap-Action SPDT-DB Brown Black (2)BN BK (1) Types GN-YW Green-Yellow RP Electrical characteristics Assigned impulse voltage (Uimp): 2500 V Assigned insulation voltage (Ui): 500 V Thermal rating (Ith): 10 A With standard contacts: Minimum voltage 10 V Minimum current 100 mA Use category: according to IEC 947.5.1 AC15 = 250 V / 6 A DC 13 = 24 V / 8 A according to UL 508 A300 - Q150 Electrical protection Integral earth wire Short-circuit protection device: IEC 947.5.1 Fuse 6 AgC (*) Other cable lengths: modify the last digit of the part number. For example: Connections 5-core cable HO5VF, 75 mm2, ext. Ø 8 mm (non-UL type cable) Approvals UL 508, UL 50 0 1 2 3 6 = = = = = M12 connector output 1.0 meter cable 2.0 meter cable (Standard) 3.0 meter cable 6.0 meter cable (**) For different cable outputs: modify the next to the last digit of the part number: 0 1 2 3 = = = = Cable side exit (Standard) Cable bottom exit Connector side exit Connector bottom exit Other information For different actuator arms, low voltage / low current contacts / low temperature, special contacts, custom wiring harness, etc.…, please consult us. Products and specifications subject to change without notice. Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 3/42 1 83 882 0 83 886 0 83 882 102 83 883 0 83 884 0 83 880 102 83 881 0 83 885 0 83 881 102 83 883 102 83 884 102 83 880 103 83 881 103 83 882 103 83 883 103 83 884 103 83 880 0 2 ● ● ● ● ● 36 (10) 108 (30) 100 (28) 10 10.3 (290) 36 (10) 108 (30) 100 (28) 10 10.4 (295) 36 (10) 108 (30) 100 (28) 10 11.1 (315) 22 in.oz. (15cmN) 52 in.oz. (35cmN) 22 in.oz. (15cmN) 10 10.3 (290) 36 (10) 108 (30) 100 (28) 10 10.9 (310) BK-BK BN-BU BK-BK BN-BU BK-BK BN-BU BK-BK BN-BU BK-BK BN-BU BK-BK BN-BU BK-BK BN-BU BK-BK BN-BU BK-BK BN-BU BK-BK BN-BU TP 16.6 POP 14.4 OL 13.3 RP 30.3 TP 28.4 83 881 0 POP 26.15 OL 25.15 RP 43.6 TP 41.7 83 882 0 POP 39.45 OL 38.45 RP 0° 83 883 0 TP 27° POP 58° OL 69° 23.6 M12 x 0.75 RP 33.4 Ø 13 RP 18.4 TP 31.6 POP 29.4 OL 28.3 83 884 0 3.4 Ø 11 3 Ø 11 3.4 83 885 0 83 886 0 M12 x 0.75 Ø 10 Ø 11 Ø 10 mm To order, specify: Standard products 2 Part number Example: Limit switch 83 881 102 Standard products, non stocked 1 Type Examples: Limit switch 83 881 003 ; cable length = 3 m - Limit switch 83 881 006 ; cable length = 6 m Products and specifications subject to change without notice. Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 3/43 Industrial Limit Switches Series 83 862 EN 50041 Conform to the following standards : EN 50041, IEC 947-5-1, VDE 0660/200 UL 508, CSA C22.2 No.14 IEC 536-1, EN 60204-1, NFC 20030 class I Degree of protection : IP 66 Function : Four-terminal double break contact element (form Zb) with positive opening NC contacts. The two moving contacts are electrically isolated from one another. Types 83 862 011 83 862 511 83 862 111 Dependent action NC + NO 83 862 001 83 862 501 83 862 101 Independent snap action NC + NO Control mechanisms - adjustable ● ● ● actuator heads 4 positions 90° ● Steel plunger ● Plunger with steel roller ● Lever with vertical plastic roller lateral Rotary head, momentary action to clockwise and/or anti-clockwise (1) ● Ø 19 offset 56 Ø 50 With adjustable lever and plastic roller offset 50.5 offset 57 Ø 22 offset 36 or 48 offset 49 adjustable offset 57 to 73 With adjustable polyamide rod actuator Flexible metal lever Independent snap action Dependent action 1 NO + 1NC ● Ø 22 offset 43.5 With lever and plastic roller Principle : Independent snap action contact 1 NO + 1NC 83 862 211 83 862 201 Ø 50 Sequence Break before make Dependent action 0 2 4,7F 21-22 13-14 21-22 13-14 0 0,9 2 21-22 13-14 6 mm 0 3,4 8F 21-22 13-14 21-22 13-14 3,2 3,4F 6 mm 0 1,5 3,4 21-22 13-14 mm 5,6 5,8F mm 0 6,5 15,5F mm 21-22 13-14 21-22 13-14 0 3 6,5 21-22 13-14 9,5 11F mm 0 6,5 15,5F mm 21-22 13-14 21-22 13-14 0 3 6,5 21-22 13-14 9,5 11F mm Electrical characteristics : Assigned insulation voltage (Ui) : 500 V Thermal rating (Ith) : 10 A Use category : A300 - Q300 AC15 = 6A/250 V - 1.9 A / 380 V DC 13 = 3A/24 V Short circuit test (under IEC 947.5.1 § 8.3.4) - Current peak 1000 A at 250 V~0.5 < cos ϕ < 0.7 - Short circuit protection (SCPD) : fuse 10 A gF - Electrical protection by internal earth terminal Connections : Saddle washer and M 3.5 screw Max. wire cross-section : 2 x 1.5 mm2 or 2.5 mm2 Positive break operation Mechanical characteristics Minimum operating N (oz.) force Minimum total N (oz.) travel force Minimum positive N (oz.) opening travel mm (in.) Minimum operating travel Minimum positive mm (in.) opening travel Differential travel mm (in.) Max. total travel mm (in.) Mechanical life (millions of operations) mini. Use Temperature °C (ºF) °C (ºF) limits Stored Degree of protection g (oz.) Weight 10 (35.5) 10 (35.5) 9 (31.7) 9 (31.7) 12 (42.3) 12 (42.3) 10 (35.3) 10 (35.3) 25 (88.2) 25 (88.2) 20 (70.5) 20 (70.5) 5 (.2) 5 (.2) 5 (.2) 5 (.2) 6 (.24) 6 (.24) 6.5 (.26) 6.5 (.26) 1.5 (.06) 6 (.24) 15 -25+80(-13+176) -40+80(-40+176) IP 66 305 (10.76) 1.5 (.06) 6 (.24) 15 -25+80(-13+176) -40+80(-40+176) IP 66 315 (11.11) 1.5 (.06) 6 (.24) 15 -25+80(-13+176) -40+80(-40+176) IP 66 320 (11.28) 1.5 (.06) 6 (.24) 15 -25+80(-13+176) -40+80(-40+176) IP 66 325 (11.46) (1) Action either right or left according to position of head Accessories Connection : 1/2˝ NPT Cover with status indicator (supplied loose) Approvals : UL listed A300 - Q300 CSA A300 - Q300 24.30 V a c 220 V a 79 250 290 79 250 291 Replacement contact block Part number 83157401 83157402 83157403 83157404 83157405 Configuration SPDT SPDT SPDT 2 NO 2 NC Function Break before make Make before break DPST - Normally open DPST - Normally closed Other information For other contact types and accessories or special modes of operation : please consult us. For dimensions see page 3/39. Products and specifications subject to change without notice. Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 3/36 1 83 862 311 83 862 301 83 862 312 83 862 302 ● 83 862 315 83 862 305 ● 83 862 316 83 862 306 ● 83 862 313 83 862 303 ● ● 83 862 317 83 862 307 83 862 318 83 862 308 83 862 314 83 862 304 83 862 611 83 862 601 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 0° 25° 60°F 75° 21-22 13-14 21-22 13-14 12° 0° 25° 21-22 13-14 32° 46°F 75° 0° 25° 21-22 13-14 21-22 13-14 12° 0° 25° 21-22 13-14 60°F 75° 32° 46°F 75° 0° 25° 60°F 75° 21-22 13-14 21-22 13-14 12° 0° 25° 21-22 13-14 32° 46°F 75° 0° 25° 60°F 75° 21-22 13-14 21-22 13-14 12° 0° 25° 21-22 13-14 0° 25° 75° 21-22 13-14 21-22 13-14 12° 0° 25° 32° 46°F 75° 21-22 13-14 32° 75° 0° 25° 75° 21-22 13-14 21-22 13-14 12° 0° 25° 32° 21-22 13-14 75° 0° 25° 75° 21-22 13-14 21-22 13-14 12° 0° 25° 21-22 13-14 32° 75° 0° 25° 75° 21-22 13-14 21-22 13-14 12° 0° 25° 32° 21-22 13-14 75° 0° 25° 75° 21-22 13-14 21-22 13-14 12° 0° 25° 32° 21-22 13-14 28cmN (40inoz) 28cmN (40inoz) 28cmN (40inoz) 28cmN (40inoz) 28cmN (40inoz) 28cmN (40inoz) 28cmN (40inoz) 28cmN (40inoz) 3 (10.5) 37cmN (52inoz) 37cmN (52inoz) 37cmN (52inoz) 37cmN (52inoz) 37cmN (52inoz) 37cmN (52inoz) 37cmN (52inoz) 37cmN (52inoz) 4.5 (15.8) 75cmN (106inoz) 75cmN (106inoz) 75cmN (106inoz) 75cmN (106inoz) 75cmN (106inoz) 75cmN (106inoz) 75cmN (106inoz) 75cmN (106inoz) 30º 30º 30º 30º 30º 30º 30º 30º 60º 60º 60º 60º 60º 60º 60º 60º 20º 75º 15 -25+80(-13+176) -40+80(-40+176) IP 66 340 (12) 20º 75º 15 -25+80(-13+176) -40+80(-40+176) IP 66 340 (12) 20º 75º 15 -25+80(-13+176) -40+80(-40+176) IP 66 340 (12) 20º 75º 15 -25+80(-13+176) -40+80(-40+176) IP 66 340 (12) 20º 75º 15 -25+80(-13+176) -40+80(-40+176) IP 66 365 (12.8) 20º 75º 15 -25+80(-13+176) -40+80(-40+176) IP 66 365 (12.8) 20º 75º 15 -25+80(-13+176) -40+80(-40+176) IP 66 365 (12.8) 20º 75º 15 -25+80(-13+176) -40+80(-40+176) IP 66 360 (12.7) 75° 3 30º 20º 75º 15 -25+80(-13+176) -40+80(-40+176) IP 66 335 (11.8) 2 To order, specify : Standard products  1 Part number Example : Limit switch 83 860 001 Standard products, non stocked 1 Type 2 Accessory Example : Limit switch 83 861 001 - Cover with status indicator 79 250 290 Products and specifications subject to change without notice. Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 3/37 Dimensions of 83 862 EN 50041 83 862 001/ 011 83 862 501/511 83 862 101/111 – 201/211 83 862 301/311 83 862 302/312 83 862 305/315 83 862 306/316 83 862 303/313 1/2˝ NPT 83 862 307/317 3 83 862 308/318 83 862 304/314 83 862 601/611 mm Products and specifications subject to change without notice. Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 3/39 Automotive Limit Switches Series 83 731 / 83 732 / 83 733 Conform to the following standards : IEC 356.1 - EN 60204.1 NFC 20030 : Class I - 83 731 - 83 732 Class III - 83 733 Degree of protection : IP 56 - IP 66 depending on type Version : 1 pole Function : 3-terminal single break twoway contact element (form C: inverter). Principle : Electrical characteristics : 83 731 3 Control mechanisms Top-mounted plunger Top-mounted plunger with roller Mechanical characteristics Minimum operating N (oz.) force Minimum total travel N (oz.) force Minimum operating travel mm (in.) 83 732 3 83 733 3 ● ● ● 15 (53) 15 (53) 6 (21.2) 35 (123.4) 35 (123.4) 25 (88.2) 2 (.079) 2 (.079) 1.5 (.059) Differential travel Max. total travel mm (in.) 0.2 (.008) 0.2 (.008) 0.2 (.008) mm (in.) 6 (.236) 6 (.236) 4 (.157) Mechanical life Temperature limits Degree of protection Weight Operations °C (°F) °C (°F) g (oz.) 106 - 5 + 70 IP 66 110 (3.9) 106 - 5 + 70 IP 66 110 (3.9) 106 - 5 + 70 IP 56 70 (2.5) Dimensions Assigned operating current (Ie) 83 731 - 83 732 : 5 A 250 V 83 733 : 5 A 50 V Thermal rating (Ith) : 12 A 1 Types 83 731 3 mm 83 732 3 83 733 3 Operating curve : Operations Resistive circuit Inductive circuit L = 5 ms R a cos ϕ = 0.8 c { A Connections : PVC cable (A05 - VV - F) 0.50 m long 3 conductors cross-section 0.75 mm2 Sheathed, ext. Ø : 7.6 mm Core connections : 1 : black (common) 2 : brown (NC) 4 : blue (NO) Electrical protection : Earthing terminal for version 83 731 and 83 732. Approvals : CSA A300. Other information For other versions, functions and special contacts or special modes of operation : please consult us. To order, specify : 1/2 meter cable 83731316 83732323  83733315 Standard products, non stocked 1 meter cable 83731319 83732315 83733314 2 meter cable 83731310 83732327 83733310 1 Type Example : Limit switch - 83 731 319 Products and specifications subject to change without notice. Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 3/46 Sealed Limit Switches Telescopic-Actuator Series 83 581 Versions Conforms to the following standards : NFC 20030 class II NFC 20010 Features Degree of protection : IP 67 Standard Low current Contact type : Three terminal single break contact element (Form C: SPDT) Operating devices Telescopic top-mounted plunger Plunger with axial roller - standard Plunger roller at 90° (G 90) - Consult Factory Layout : Contact Type Electrical characteristics : Assigned working currents (Ie): standard 10 A - 250 V~ low current 0.1 A - 250 V~ Electrical endurance : Standard : 10 A - 250 V : 40 000 operations 5 A - 250 V : 100 000 operations Low current : Designed for use from1 to 100 mA at 4 to 30 volts. In these conditions, the electrical endurance exceeds the mechanical life. Connections : Flexible leads 3x1 mm2. Length 0.50 m Cable 3x0,75 mm2. Length 0.50 m Core connections: 1 : black 2 : brown 4 : blue Form C – SPDT Mechanical characteristics Minimum operating force Minimum total travel force Movement differential Minimum operating travel Total travel max. Mechanical life Temperature limits Degree of protection Weight N (oz) N (oz) mm (in) mm (in) mm (in) Operations °C (°F) g (oz) Connections Flexible leads Cable * Rating restricted to 8A Lead position - right (D) Lead position - left (G) Output on left Dimensions mm(in) 83 581 0 M10x0.75 Ø7 (.28) R10 spherical Ø12 (.47) 27.4 (1.08) 1.2 (.047) 5.5 max 18.7 (74) Nuts 14 across flats Depth 2 6 (.24) 25 (1) 14 max (.55) Other information For other accessories and special contacts, or special modes of operation, please consult factory. Products and specifications subject to change without notice. Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 3/48 83 581 0 83 581 1 S S 1 2 B B ● ● ● ● ● ● 3 C C C C 5 (17.6) 20 (70.5) 1 (.04) 2.5 (.1) 5.5 (.22) 105 -20 to 85 (-4 to 185) IP 67 40 (1.4) 5 (17.6) 20 (70.5) 1 (.04) 2.5 (.1) 5.5 (.22) 105 -20 to 85 (-4 to 185) IP 67 40 (1.4) 5 (17.6) 20 (70.5) 1 (.04) 2.5 (.1) 5 (.2) 105 -20 to 85 (-4 to 185) IP 67 45 (1.6) 5 (17.6) 20 (70.5) 1 (.04) 2.5 (.1) 5 (.2) 105 -20 to 85 (-4 to 185) IP 67 45 (1.6) R L C* R L C R L C* R L C 4 3 83 581 1 Roller either in line (standard) or at 90° Ø8x3 (.315x.12) M10x0.75 5.5 max 1.5 max (.06) 27.4 (1.08) 26.5 (1.04) 6.5 max (.26) Nuts 14 across flats Depth 2 6 (.24) 25 (1) 14 max (.55) To order, please specify : Example : 835810 S C C • 1 Switch Type 835810 835811 2 Current Level S - 10A B -
83880112 价格&库存

很抱歉,暂时无法提供与“83880112”相匹配的价格&库存,您可以联系我们找货

免费人工找货