Compact Limit Switches Series 83 880 IP 67
Conforms to the following standards
IEC / EN 60947.5.1
Dimensional conformity: NFC 63145
Low voltage directive: 73/23/EEC and 93/68/EEC
Electric shock protection: NFC 20030 or IEC 60536 class 1, degree of
pollution 3.
Temperature specification: –25°/+70°C –13°/+158°F
Degree of protection
According to IEC 62529:
According to NEMA :
IP 66 / 67
Type 1, 3, 4, 6, 13
Function
Four-terminal double break contact element (form Zb) with positive
opening NC contacts. The two moving contacts are electrically isolated
from one another.
Standard
Plunger or roller at 90°
Standard Part Number (Cable length = 2.0 meters, exit: side)
Actuator Type
Metal plunger
Metal roller plunger
Metal plunger with threaded barrel
Roller plunger - metal with threaded barrel
Metal roller lever (operates in both directions)
Mechanical characteristics
Minimum positive opening force
Minimum total travel force
Force d’ouverture positive minimum
Mechanical life
Weight
Sequences
Dimensions
BK
(4)
mm
See sequence
diagram
83 880
Blue Black
millions of operations
g
UL cables are 4 black wires numbered 1-4
with a GRN-YLW ground wire
Zb
(3) BU
N (cmN)
N (cmN)
Positions: nominal data
Principle
Snap-Action SPDT-DB
Brown Black
(2)BN BK (1)
Types
GN-YW
Green-Yellow
RP
Electrical characteristics
Assigned impulse voltage (Uimp): 2500 V
Assigned insulation voltage (Ui): 500 V
Thermal rating (Ith): 10 A
With standard contacts:
Minimum voltage 10 V
Minimum current 100 mA
Use category:
according to IEC 947.5.1
AC15 = 250 V / 6 A
DC 13 = 24 V / 8 A
according to UL 508
A300 - Q150
Electrical protection
Integral earth wire
Short-circuit protection device: IEC 947.5.1
Fuse 6 AgC
(*) Other cable lengths:
modify the last digit of the part number. For example:
Connections
5-core cable HO5VF, 75 mm2, ext. Ø 8 mm (non-UL type cable)
Approvals
UL 508, UL 50
0
1
2
3
6
=
=
=
=
=
M12 connector output
1.0 meter cable
2.0 meter cable (Standard)
3.0 meter cable
6.0 meter cable
(**) For different cable outputs:
modify the next to the last digit of the part number:
0
1
2
3
=
=
=
=
Cable side exit (Standard)
Cable bottom exit
Connector side exit
Connector bottom exit
Other information
For different actuator arms, low voltage / low current contacts / low temperature, special contacts, custom wiring harness, etc.…, please consult us.
Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
3/42
1
83 882 0
83 886 0
83 882 102
83 883 0
83 884 0
83 880 102
83 881 0
83 885 0
83 881 102
83 883 102
83 884 102
83 880 103
83 881 103
83 882 103
83 883 103
83 884 103
83 880 0
2
●
●
●
●
●
36 (10)
108 (30)
100 (28)
10
10.3 (290)
36 (10)
108 (30)
100 (28)
10
10.4 (295)
36 (10)
108 (30)
100 (28)
10
11.1 (315)
22 in.oz. (15cmN)
52 in.oz. (35cmN)
22 in.oz. (15cmN)
10
10.3 (290)
36 (10)
108 (30)
100 (28)
10
10.9 (310)
BK-BK
BN-BU
BK-BK
BN-BU
BK-BK
BN-BU
BK-BK
BN-BU
BK-BK
BN-BU
BK-BK
BN-BU
BK-BK
BN-BU
BK-BK
BN-BU
BK-BK
BN-BU
BK-BK
BN-BU
TP
16.6
POP
14.4
OL
13.3
RP
30.3
TP
28.4
83 881 0
POP
26.15
OL
25.15
RP
43.6
TP
41.7
83 882 0
POP
39.45
OL
38.45
RP
0°
83 883 0
TP
27°
POP
58°
OL
69°
23.6
M12 x 0.75
RP
33.4
Ø 13
RP
18.4
TP
31.6
POP
29.4
OL
28.3
83 884 0
3.4
Ø 11
3
Ø 11
3.4
83 885 0
83 886 0
M12 x 0.75
Ø 10
Ø 11
Ø 10
mm
To order, specify:
Standard products
2
Part number
Example: Limit switch 83 881 102
Standard products,
non stocked
1
Type
Examples: Limit switch 83 881 003 ; cable length = 3 m - Limit switch 83 881 006 ; cable length = 6 m
Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
3/43
Industrial Limit Switches Series 83 862 EN 50041
Conform to the following standards :
EN 50041, IEC 947-5-1, VDE 0660/200
UL 508, CSA C22.2 No.14
IEC 536-1, EN 60204-1, NFC 20030
class I
Degree of protection : IP 66
Function : Four-terminal double break
contact element (form Zb) with positive
opening NC contacts.
The two moving contacts are
electrically isolated from one another.
Types
83 862 011
83 862 511
83 862 111
Dependent action NC + NO
83 862 001
83 862 501
83 862 101
Independent snap action NC + NO
Control mechanisms - adjustable
●
●
●
actuator heads 4 positions 90°
●
Steel plunger
●
Plunger with steel roller
●
Lever with
vertical
plastic roller
lateral
Rotary head, momentary action to clockwise and/or anti-clockwise (1)
●
Ø 19 offset 56
Ø 50
With adjustable
lever and plastic
roller
offset 50.5
offset 57
Ø 22 offset 36 or 48
offset 49
adjustable offset
57 to 73
With adjustable polyamide rod actuator
Flexible metal lever
Independent snap action
Dependent
action
1 NO + 1NC
●
Ø 22 offset 43.5
With lever and
plastic roller
Principle :
Independent
snap
action contact
1 NO + 1NC
83 862 211
83 862 201
Ø 50
Sequence
Break before make
Dependent action
0
2
4,7F
21-22
13-14
21-22
13-14
0
0,9
2
21-22
13-14
6 mm
0
3,4
8F
21-22
13-14
21-22
13-14
3,2 3,4F 6 mm
0
1,5
3,4
21-22
13-14
mm
5,6 5,8F mm
0
6,5
15,5F mm
21-22
13-14
21-22
13-14
0
3
6,5
21-22
13-14
9,5 11F mm
0
6,5
15,5F mm
21-22
13-14
21-22
13-14
0
3
6,5
21-22
13-14
9,5 11F mm
Electrical characteristics :
Assigned insulation voltage (Ui) :
500 V
Thermal rating (Ith) : 10 A
Use category : A300 - Q300
AC15 = 6A/250 V - 1.9 A / 380 V
DC 13 = 3A/24 V
Short circuit test (under
IEC 947.5.1 § 8.3.4)
- Current peak 1000 A
at 250 V~0.5 < cos ϕ < 0.7
- Short circuit protection (SCPD) :
fuse 10 A gF
- Electrical protection by internal earth
terminal
Connections :
Saddle washer and M 3.5 screw
Max. wire cross-section : 2 x 1.5 mm2
or 2.5 mm2
Positive break operation
Mechanical characteristics
Minimum operating
N (oz.)
force
Minimum total
N (oz.)
travel force
Minimum positive
N (oz.)
opening travel
mm (in.)
Minimum operating travel
Minimum positive
mm (in.)
opening travel
Differential travel
mm (in.)
Max. total travel
mm (in.)
Mechanical life (millions of operations) mini.
Use
Temperature
°C (ºF)
°C (ºF)
limits
Stored
Degree of protection
g (oz.)
Weight
10 (35.5)
10 (35.5)
9 (31.7)
9 (31.7)
12 (42.3)
12 (42.3)
10 (35.3)
10 (35.3)
25 (88.2)
25 (88.2)
20 (70.5)
20 (70.5)
5 (.2)
5 (.2)
5 (.2)
5 (.2)
6 (.24)
6 (.24)
6.5 (.26)
6.5 (.26)
1.5 (.06)
6 (.24)
15
-25+80(-13+176)
-40+80(-40+176)
IP 66
305 (10.76)
1.5 (.06)
6 (.24)
15
-25+80(-13+176)
-40+80(-40+176)
IP 66
315 (11.11)
1.5 (.06)
6 (.24)
15
-25+80(-13+176)
-40+80(-40+176)
IP 66
320 (11.28)
1.5 (.06)
6 (.24)
15
-25+80(-13+176)
-40+80(-40+176)
IP 66
325 (11.46)
(1) Action either right or left according to position of head
Accessories
Connection :
1/2˝ NPT
Cover with status indicator
(supplied loose)
Approvals :
UL listed A300 - Q300 CSA A300 - Q300
24.30 V a c
220 V a
79 250 290
79 250 291
Replacement contact block
Part number
83157401
83157402
83157403
83157404
83157405
Configuration
SPDT
SPDT
SPDT
2 NO
2 NC
Function
Break before make
Make before break
DPST - Normally open
DPST - Normally closed
Other information
For other contact types and accessories or special modes of operation : please consult us.
For dimensions see page 3/39.
Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
3/36
1
83 862 311
83 862 301
83 862 312
83 862 302
●
83 862 315
83 862 305
●
83 862 316
83 862 306
●
83 862 313
83 862 303
●
●
83 862 317
83 862 307
83 862 318
83 862 308
83 862 314
83 862 304
83 862 611
83 862 601
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
0°
25°
60°F 75°
21-22
13-14
21-22
13-14
12°
0° 25°
21-22
13-14
32° 46°F 75°
0°
25°
21-22
13-14
21-22
13-14
12°
0° 25°
21-22
13-14
60°F 75°
32° 46°F 75°
0°
25°
60°F 75°
21-22
13-14
21-22
13-14
12°
0° 25°
21-22
13-14
32° 46°F 75°
0°
25°
60°F 75°
21-22
13-14
21-22
13-14
12°
0° 25°
21-22
13-14
0°
25°
75°
21-22
13-14
21-22
13-14
12°
0° 25°
32° 46°F 75°
21-22
13-14
32°
75°
0°
25°
75°
21-22
13-14
21-22
13-14
12°
0° 25°
32°
21-22
13-14
75°
0°
25°
75°
21-22
13-14
21-22
13-14
12°
0° 25°
21-22
13-14
32°
75°
0°
25°
75°
21-22
13-14
21-22
13-14
12°
0° 25°
32°
21-22
13-14
75°
0°
25°
75°
21-22
13-14
21-22
13-14
12°
0° 25°
32°
21-22
13-14
28cmN (40inoz)
28cmN (40inoz)
28cmN (40inoz)
28cmN (40inoz)
28cmN (40inoz)
28cmN (40inoz)
28cmN (40inoz)
28cmN (40inoz)
3 (10.5)
37cmN (52inoz)
37cmN (52inoz)
37cmN (52inoz)
37cmN (52inoz)
37cmN (52inoz)
37cmN (52inoz)
37cmN (52inoz)
37cmN (52inoz)
4.5 (15.8)
75cmN (106inoz)
75cmN (106inoz)
75cmN (106inoz)
75cmN (106inoz)
75cmN (106inoz)
75cmN (106inoz)
75cmN (106inoz)
75cmN (106inoz)
30º
30º
30º
30º
30º
30º
30º
30º
60º
60º
60º
60º
60º
60º
60º
60º
20º
75º
15
-25+80(-13+176)
-40+80(-40+176)
IP 66
340 (12)
20º
75º
15
-25+80(-13+176)
-40+80(-40+176)
IP 66
340 (12)
20º
75º
15
-25+80(-13+176)
-40+80(-40+176)
IP 66
340 (12)
20º
75º
15
-25+80(-13+176)
-40+80(-40+176)
IP 66
340 (12)
20º
75º
15
-25+80(-13+176)
-40+80(-40+176)
IP 66
365 (12.8)
20º
75º
15
-25+80(-13+176)
-40+80(-40+176)
IP 66
365 (12.8)
20º
75º
15
-25+80(-13+176)
-40+80(-40+176)
IP 66
365 (12.8)
20º
75º
15
-25+80(-13+176)
-40+80(-40+176)
IP 66
360 (12.7)
75°
3
30º
20º
75º
15
-25+80(-13+176)
-40+80(-40+176)
IP 66
335 (11.8)
2
To order, specify :
Standard products
1
Part number
Example : Limit switch 83 860 001
Standard products,
non stocked
1
Type
2
Accessory
Example : Limit switch 83 861 001 - Cover with status indicator 79 250 290
Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
3/37
Dimensions of 83 862 EN 50041
83 862 001/ 011
83 862 501/511
83 862 101/111 – 201/211
83 862 301/311
83 862 302/312
83 862 305/315
83 862 306/316
83 862 303/313
1/2˝ NPT
83 862 307/317
3
83 862 308/318
83 862 304/314
83 862 601/611
mm
Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
3/39
Automotive Limit Switches Series 83 731 / 83 732 / 83 733
Conform to the following standards :
IEC 356.1 - EN 60204.1
NFC 20030 : Class I - 83 731 - 83 732
Class III - 83 733
Degree of protection :
IP 56 - IP 66 depending on type
Version : 1 pole
Function : 3-terminal single break twoway contact element (form C: inverter).
Principle :
Electrical characteristics :
83 731 3
Control mechanisms
Top-mounted plunger
Top-mounted plunger with roller
Mechanical characteristics
Minimum operating
N (oz.)
force
Minimum total travel
N (oz.)
force
Minimum operating travel
mm (in.)
83 732 3
83 733 3
●
●
●
15 (53)
15 (53)
6 (21.2)
35 (123.4)
35 (123.4)
25 (88.2)
2 (.079)
2 (.079)
1.5 (.059)
Differential travel
Max. total travel
mm (in.)
0.2 (.008)
0.2 (.008)
0.2 (.008)
mm (in.)
6 (.236)
6 (.236)
4 (.157)
Mechanical life
Temperature limits
Degree of protection
Weight
Operations
°C (°F)
°C (°F)
g (oz.)
106
- 5 + 70
IP 66
110 (3.9)
106
- 5 + 70
IP 66
110 (3.9)
106
- 5 + 70
IP 56
70 (2.5)
Dimensions
Assigned operating current (Ie)
83 731 - 83 732 : 5 A 250 V
83 733
: 5 A 50 V
Thermal rating (Ith) : 12 A
1
Types
83 731 3
mm
83 732 3
83 733 3
Operating curve :
Operations
Resistive circuit
Inductive circuit
L = 5 ms
R
a cos ϕ = 0.8
c
{
A
Connections :
PVC cable (A05 - VV - F) 0.50 m long
3 conductors cross-section 0.75 mm2
Sheathed, ext. Ø : 7.6 mm
Core connections : 1 : black (common)
2 : brown (NC)
4 : blue (NO)
Electrical protection :
Earthing terminal for version 83 731
and 83 732.
Approvals :
CSA A300.
Other information
For other versions, functions and special contacts or special modes of
operation : please consult us.
To order, specify :
1/2 meter cable
83731316
83732323
83733315
Standard products,
non stocked
1 meter cable
83731319
83732315
83733314
2 meter cable
83731310
83732327
83733310
1
Type
Example : Limit switch - 83 731 319
Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
3/46
Sealed Limit Switches Telescopic-Actuator Series 83 581
Versions
Conforms to the following standards : NFC 20030 class II NFC 20010
Features
Degree of protection : IP 67
Standard
Low current
Contact type : Three terminal single break contact element
(Form C: SPDT)
Operating devices
Telescopic top-mounted plunger
Plunger with axial roller - standard
Plunger roller at 90° (G 90) - Consult Factory
Layout :
Contact Type
Electrical characteristics :
Assigned working currents (Ie): standard 10 A - 250 V~
low current 0.1 A - 250 V~
Electrical endurance :
Standard :
10 A - 250 V : 40 000 operations
5 A - 250 V : 100 000 operations
Low current : Designed for use from1 to 100 mA at 4 to 30 volts.
In these conditions, the electrical endurance exceeds
the mechanical life.
Connections :
Flexible leads 3x1 mm2. Length 0.50 m
Cable 3x0,75 mm2. Length 0.50 m
Core connections: 1 : black
2 : brown
4 : blue
Form C – SPDT
Mechanical characteristics
Minimum operating force
Minimum total travel force
Movement differential
Minimum operating travel
Total travel max.
Mechanical life
Temperature limits
Degree of protection
Weight
N (oz)
N (oz)
mm (in)
mm (in)
mm (in)
Operations
°C (°F)
g (oz)
Connections
Flexible leads
Cable
* Rating restricted to 8A
Lead position - right (D)
Lead position - left (G)
Output on left
Dimensions
mm(in)
83 581 0
M10x0.75
Ø7
(.28)
R10 spherical
Ø12 (.47)
27.4 (1.08)
1.2
(.047)
5.5 max
18.7 (74)
Nuts 14 across flats
Depth 2
6 (.24)
25 (1)
14 max
(.55)
Other information
For other accessories and special contacts, or special modes of operation, please consult factory.
Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
3/48
83 581 0
83 581 1
S
S
1
2
B
B
●
●
●
●
●
●
3
C
C
C
C
5 (17.6)
20 (70.5)
1 (.04)
2.5 (.1)
5.5 (.22)
105
-20 to 85 (-4 to 185)
IP 67
40 (1.4)
5 (17.6)
20 (70.5)
1 (.04)
2.5 (.1)
5.5 (.22)
105
-20 to 85 (-4 to 185)
IP 67
40 (1.4)
5 (17.6)
20 (70.5)
1 (.04)
2.5 (.1)
5 (.2)
105
-20 to 85 (-4 to 185)
IP 67
45 (1.6)
5 (17.6)
20 (70.5)
1 (.04)
2.5 (.1)
5 (.2)
105
-20 to 85 (-4 to 185)
IP 67
45 (1.6)
R
L
C*
R
L
C
R
L
C*
R
L
C
4
3
83 581 1
Roller either in line
(standard) or at 90°
Ø8x3
(.315x.12)
M10x0.75
5.5 max
1.5 max (.06)
27.4 (1.08)
26.5 (1.04)
6.5 max (.26)
Nuts 14 across flats
Depth 2
6 (.24)
25 (1)
14 max
(.55)
To order, please specify :
Example : 835810 S C C •
1
Switch Type
835810
835811
2
Current Level
S - 10A
B -