0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2511

2511

  • 厂商:

    B&K

  • 封装:

    -

  • 描述:

    60MHZ HANDHELD DIG OSCOPE

  • 数据手册
  • 价格&库存
2511 数据手册
Data Sheet Handheld Digital Storage Oscilloscopes 2510 Series Features and Benefits ■ 60 MHz (2511/2515) and 100 MHz (2512/2516) bandwidth ■ 1 GSa/s sample rate ■ Deep waveform memory up to 2 Mpts ■ 2 fully isolated and floating 1,000 V CAT II, 600 V CAT III rated inputs (isolated models 2515 and 2516) ■ 300 V CAT II rated inputs (non-isolated models 2511 and 2512) ■ Built-in 6000-count DMM with dedicated terminals for current measurement ■ Scope and meter trend plot functions for data logging ■ Bright 5.7” color display ■ Compact and lightweight – 3.4 lbs (1.54 kg) ■ FFT including four additional math functions Add, Subtract, Multiply, and Divide The 2510 Series handheld digital storage oscilloscopes provide floating measurement and recorder capabilities with a built-in digital multimeter (DMM), all in one portable and lightweight package. These versatile 60 MHz and 100 MHz bandwidth scopes offer 1 GSa/s sample rates, 2 Mpts waveform memory, 32 automatic measurements, and multiple recording functions to capture transient or long-term signal behavior. The built-in 6000-count multimeter allows users to quickly switch over from an oscilloscope to a DMM to measure DC/AC voltage and current, resistance, and capacitance, including diode and continuity tests. Technical data subject to change © B&K Precision Corp. 2022 These handheld scopes feature many useful recording functions such as trend plot, which allows data logging from the scope or multimeter. Additionally, the scope recorder function offers users 7 Mpts record length on a single channel or 3.5 Mpts on dual channel. ■ 32 automatic measurements ■ USB host port for saving and recalling waveform setups, data, and screenshots on a USB flash drive ■ Software provided for remote PC control ■ Advanced tools include digital filters with adjustable limits, scope and waveform recorder mode The 2510 Series handheld oscilloscopes are ideal for industrial applications, power systems, electronics design, and field test and service. ■ Multi-language user interface ■ Up to four hours of continuous battery operation Model 2511 2512 2515 2516 Bandwidth 60 MHz 100 MHz 60 MHz 100 MHz Channels 2 non-isolated 2 fully isolated Typical Applications General electronics Power electronics and industrial www.bkprecision.com Handheld Digital Storage Oscilloscopes 2510 Series Front Panel Scope input terminals Á Top View Durable rubber bezel Provides grip and protection against accidental bumps. 5.7” color display Scope and meter mode buttons Auto setup Vertical, horizontal, and trigger controls are automatically adjusted for fast signal display. Recorder function button Use the scope recorder or trend plot functions to log oscilloscope or multimeter measurements. Trigger menu button CH2 selection button CH1 selection button CH1 vertical controls USB ports Horizontal controls CH2 vertical controls Á Multimeter input terminals Dedicated terminals provided for current measurements. Side View Mini USB device port Compensate your probe or enable remote control from a PC. USB host port Connect your USB flash drive to conveniently store and recall waveform data, setups, and screenshots. 2 DC power adapter input www.bkprecision.com Handheld Digital Storage Oscilloscopes 2510 Series The tools you need 2 Mpts Deep Memory Built-in Digital Multimeter See more details in your waveform with deep memory. When enabled, waveforms can be captured in high resolution while maintaining a high sample rate over a wider period of time than other comparable scopes. Speed up troubleshooting with the built-in 6000-count multimeter. Measurement functions include AC/DC voltage and current, resistance, capacitance, diode, and continuity test. Powerful Measurement Functions Scope and Waveform Recorder Modes Scope and Meter Trend Plot Functions Scope Trend Plot Meter Trend Plot Display and measure the input signal’s frequency spectrum. Select one of the 4 FFT windows: Rectangular, Hanning, Hamming, and Blackman. Use cursors to measure the spectral component’s magnitude and frequency. Monitor and analyze long-term signal behavior by recording data continuously over a period of time. These modes allow recorded data to be played back for post acquisition analysis. Digital Filtering Portable Operation Filter out unwanted signal components such as various types of noise with built-in digital filters. Choose from Low-Pass, High-Pass, Band-Pass, and Band-Stop filters. 3 Capture intermittent errors in your system. The trend plot function can be used with the oscilloscope or built-in DMM to plot measurement values over time. Up to two voltage or time parameters can be selected by the scope, and any one of the multimeter’s measurement functions can be graphed. These data points can then be exported to a CSV file for further analysis. PC Connectivity Quickly troubleshoot in the field using battery powered operation. Built for portability, the 2510 Series handheld digital oscilloscopes are rugged, compact, and lightweight. All models come standard with travel case for safe transport on the road. PC software provided (free download from www.bkprecision.com) for seamless integration between the oscilloscope and PC. Capture and transfer waveforms, screen images, setups and measurement results to a Windows PC via the USB device port on the side of the instrument. A USB host port is also available for quick and easy screen saving. www.bkprecision.com Handheld Digital Storage Oscilloscopes 2510 Series Floating and Differential Measurements Safety Rated High Bandwidth Oscilloscope Probes Many industrial applications such as power electronics require measurements of high voltages and currents that are not referenced to ground. This poses an issue with traditional line-powered oscilloscopes, which typically have signal common connected to the chassis of the oscilloscope. This means all measurements must be made relative to earth ground, preventing users from making differential measurements where none of the test points are referenced to ground. As a workaround, some people choose to float an oscilloscope by removing the connection between the instrument's chassis and power line ground. Floating a scope is not recommended as it can put the user at a safety risk. Parasitic capacitance is also induced in the measurement which can cause ringing and invalidate the measurement. The 2510 Series allows engineers and technicians to make accurate and safe measurements when the signal reference is floating. Fully Isolated Channel Design for Safe Measurements (models 2515/2516 only) between inputs and the digital acquisition circuit. Isolating the ground references eliminate ground loops and help reduce channel noise and crosstalk. Models 2515 and 2516 offer two CAT III 600 V input channels for floating measurements and feature an electrically isolated circuit design Probe Model PR250SA Probe Model PR150SA All 2510 Series models come standard with high bandwidth, safety certified passive probes (one per channel) to help you get the most out of your scope. 2515/2516 block diagram Model Included Probes 2511 Two 150 MHz bandwidth, x1/x10 probes rated for 300 V CATII measurements 2512 2515 2516 Two touch-protected 250 MHz bandwidth, x10 probes rated for 1000 V CATII, 600 V CATIII measurements Input Signal and Float Voltage Safety Ratings 4 Model 2511 / 2512 2515 / 2516 Maximum signal input safety rating with included probe 300 Vrms CAT II 1000 Vrms CAT II, 600 Vrms CAT III Maximum signal input safety rating without probe 300 Vrms CAT II 300 Vrms CAT II Maximum reference floating safety rating 30 Vrms 1000 Vrms CAT II, 600 Vrms CAT III www.bkprecision.com Handheld Digital Storage Oscilloscopes 2510 Series Digital Storage Oscilloscope Specifications Models 2511 2512 2515 2516 100 MHz 60 MHz 100 MHz Performance Characteristics Bandwidth 60 MHz 1 GSa/s (half-channel interleaved)(1), 500 MSa/s (per channel) Real Time Sampling Rate Channels Rise Time 2 non-isolated < 5.8 ns 2 isolated < 3.5 ns < 5.8 ns Ch-to-Ch Isolation (both channels at same V/div setting) > 100:1 at 50 MHz Memory Depth 40 kpts (half-channel interleaved)(1)(2), 20 kpts (per channel) Deep Memory(3) 2 Mpts (half-channel interleaved)(1), 1 Mpts (per channel) Vertical Resolution Vertical Sensitivity 8 bits 2 mV/div – 100 V/div (1-2-5 order) 5 mV/div – 100 V/div (1-2-5 order) DC Gain Accuracy 5 mV/div-100 V/div: ≤ ± 4 % Max. BNC Input Voltage CATII 300 Vrms from BNC signal to BNC shell Max. Input Voltage for Probe Channel Voltage Offset Range PR150SA(4) : 1x/10x CAT II 300 V PR250SA(5)(6): 10x CAT III 600 V, CATII 1000 V 2 mV - 200 mV : ±1.6 V 5 mV - 200 mV : ±1.6 V 206 mV - 10 V : ±40 V 206 mV - 10 V : ±40 V 10.2 V - 100 V : ±400 V 10.2 V - 100 V : ±400 V Bandwidth Limit Horizontal Scan Range 20 MHz (-3 dB) 5.0 nS/div - 50 S/div 2.5 nS/div - 50 S/div 5.0 nS/div - 50 S/div Timebase Accuracy ± 50 ppm measured over 1 ms interval Input Coupling AC, DC, GND Input Impedance < 3.5 ns 1 MΩ +/- 2 % || 18 pF ± 3 pF 2.5 nS/div - 50 S/div 1 MΩ +/- 2 % || 16 pF ± 3 pF Probe Attenuation Selectable Factors 1X, 5X, 10X, 50X, 100X, 500X, 1000X Vertical and Horizontal Zoom Vertically or horizontally expand or compress a live or stopped waveform I/O Interface USB USB host port support USB flash drives (FAT format) mini-USB device port for PC connectivity and probe compensation Acquisition Modes Sampling Display sample data only Peak Detect Capture the maximum and minimum values of a signal Average Waveform averaged, selectable from 4, 16, 32, 64, 128, 256 Trigger System Edge, Pulse Width, Video*, Slope, Alternative Trigger Types 5 *Support signal formats: PAL/SECAM, NTSC Trigger condition: odd field, even field, all lines, or line number Trigger Modes Auto, Normal, Single Trigger Coupling AC, DC, LF reject, HF reject Trigger Source CH1, CH2 Trigger Level Range ± 6 divisions from center of display Trigger Displacement Pre-trigger: Memory depth / 2* sampling Delay Trigger: 268.04 div Pulse Width Trigger Positive slope (>, , , , 6 A DC or AC rms for 10 seconds ON and 15 minutes OFF. For AC current ranges, frequency is verified for 30 Hz to 1 kHz. ± (1 % + 5 digits) AC Voltage(2) Recorder Range Resolution Accuracy 60.00 mV 10 µV ± (1 % + 15 digits) 600.0 mV 100 µV 6.000 V 1 mV 60.00 V 10 mV 600.0 V 100 mV Display Mode Full view, Normal 750 V 1V Record Length 1.2M dots, > 24 hours Number of Channels 1 ± (1 % + 5 digits) DC and AC Current(3)(4) Range Resolution 58.00 mA 10 µA 580.0 mA 100 µA 5.800 A 1 mA 10.00 A 10 mA Accuracy ± (1.5 % + 5 digits) Range 600.0 Ω 6.000 kΩ 60.00 kΩ 600.0 kΩ Resolution 0.1 Ω Display Mode Full view, Normal Record Length 800k points, > 24 hours Number of Channels 2 Multimeter Trend Plot Scope Recorder Display Mode Full view, Normal Max. Record Length Single Channel: 7 M pts Dual Channel: 3.5 M pts Number of Channels 2 Maximum Record Size to External Storage Accuracy 4 GB, 3000 hours 1Ω 10 Ω 100 Ω 6.000 MΩ 1 kΩ 60.00 MΩ 10 kΩ v100422 Scope Trend Plot ± (2.5 % + 5 digits) Resistance 7 Range ± (1 % + 5 digits) ± (3 % + 5 digits) Included Accessories User manual, passive probes (one per channel), pair of DMM test leads, 7.4 V Li-ion battery BP2510, USB cable, probe compensation connector, AC power adapter, travel case LC2510B and certificate of calibration www.bkprecision.com

很抱歉,暂时无法提供与“2511”相匹配的价格&库存,您可以联系我们找货

免费人工找货