Model 2121
30 MHz Analog Oscilloscope
With Frequency Counter
Data Sheet
■ Dual or single trace operation
5 mV/div sensitivity
■ AUTO/NORM triggered sweep operation with AC,
TVH,TVV and line coupling
■Calibrated 23 step time base with x 10 magnifier
■ Compact low-profile design
■ Built-in 50 MHz frequency counter
Specifications
model
2121
VERTICAL AMPLIFIERS (Ch 1 and CH 2)
Sensitivity
Attenuator
5 mV/div to 5 V/div, 1 mV/div to 1 V/div at X5
10 steps in 1-2-5 sequence. Vernier control provides full
adjustment between steps.
Accuracy
±3%, ±5% at X5
Input Resistance
1 MΩ ±2%
Input Capacitance
25 pF ±10pF
Frequency Response
5 mV to 5 V/div: DC to 30 MHz (-3dB). X5: DC to 10 MHz
(-3dB)
Rise Time
12 ns (Overshoot
很抱歉,暂时无法提供与“2121”相匹配的价格&库存,您可以联系我们找货