0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
110507

110507

  • 厂商:

    EASYBRAID

  • 封装:

    -

  • 描述:

    MAINFILTER-HEPACHEMICAL

  • 详情介绍
  • 数据手册
  • 价格&库存
110507 数据手册
Brochure 01/13 “Protecting People and the Environment with Innovative Technology” Protecting Introduction Purex offers an extensive range of fume extraction solutions. These range from machines to protect a single person to powerful centralised systems to cater for multiple users or high volume continuous automated processes (e.g. a PCB production line). Purex has the experience, products and support infrastructure to help ensure that: • The correct machine is specified first time. • The process performs at the optimum level. • Employees are protected from hazardous fumes. • The company complies with health & safety legislation • Product quality is maintained • Process machinery is protected from dust and fumes. • Contaminated air is filtered, not pumped into the environment. APPLICATIONS • Laser Coding and Marking • Continuous Ink Jet Coding and Marking • Laser Engraving • Wide Format Printing • Dye Sublimation • • • • • • Reflow & Wave Soldering Manual Soldering Laser & Robotic Soldering Underfill & Conformal Coating Cleanrooms & Laboratories Education & Engineering NEW.... NEW.... FumeCube Max Tip Extraction Kits • Ideal for dusty applications & lead free solder. • Can be used with small lasers, in dentistry, in jewellery making and many other applications. • Uses patented filter technology. • Individual kits to fit tip extraction onto popular models of soldering iron. • Prevents tip cooling. • Simple to install and comfortable to use. NEW.... NEW.... Large Diameter Arms • Ideal for applications requiring high airflow. • Can be attached to a Purex extractor to give mobility. • Fully adjustable. • 113669 filter for Acidic Vapours such as HCN or for engraving ABF plastic. • 200316 high performance F8/F9 pre-filter pad for FumeCubes. • 125mm connection kits for conformal coating and other systems. • Parts and Spares information for easy reference. People and the Environment with Innovative Technology Health & Safety Legislation Local and international health and safety legislation (such as COSHH, NIOSHH, OSHA etc) states that it is the employers responsibility to protect the health, welfare and safety of their employees. Failure to do so can result in expensive legal action, potential fines and poor employee relations. The Need for Fume Extraction Many types of dust and fume are hazardous to health if inhaled. People can become permanently sensitised to fumes which means that continued exposure, even to very small amounts of fume, may cause asthma attacks or other respiratory diseases. A high performance fume extraction system will help to:• Protect employee health. • Ensure compliance with Health & Safety regulations such as OSHA, NIOSH C.O.S.H.H, MAK, AFNOR and HSG258 or equivalent. • Increase production speeds. • Reduce complaints by operators due to odours, dust and vapours. • Avoid the possible cost of health compensation claims. • Reduce the cost & time to clean laser lenses, conveyors, guarding, soldering machines and other equipment. • Reduce product contamination. • Provide a better working environment. • Reduce downtime. Purex LEV systems sit next to the process and the extraction rate can be altered precisely to suit the application. Purex machines are also easy to move if the process moves. Which Extraction System? See comparison table below... LEV systems have additional benefits over external exhaust systems. There are usually two types of extraction system available:- “ Purex LEV engineers are qualified to BOHS P601 or P602 • External - pump contaminated air outside • Internal - at source capture and filtration or LEV (local exhaust ventilation) system In our opinion the best system to use is an LEV system such as a Purex. These capture fumes at the source thereby preventing fumes escaping into the workplace. They also filter hazardous particles and gasses which would otherwise be pumped into the outside environment causing pollution. ” Using an internal filter system also avoids issues with environmental regulations and potential complaints from neighbouring businesses about fumes and odours. COMPARISON: Exhaust into the Environment System “vs” Purex LEV System... Comparison Question Exhausting into the Environment Purex LEV System How long will it take to install the system? Several days on average. In many cases just minutes. Will there be any disruption in the workplace? Scaffold, ladders etc. may be required in several places, disrupting work for lengthy periods. Minor, if any. Can the system be moved? Only with scaffold etc. and disruption to work. Yes. Simply disconnect and push to new location. Are holes in the building required? Yes. They need to be specially cut and sealed. No. Are external emissions regulations a problem? Company must investigate and obey local laws. Not applicable. Is there any energy lost e.g. heating costs? Energy (and therefore money) is wasted when heated or conditioned air is pumped outside. No energy or heat is lost as the air is recycled. So costs are lowered. Are there any ducting / installation costs? Potentially expensive - as ducting needs to be purchased and specialist installation is required. Minimal if any, depending on process. Are there any cleaning costs? Specialist cleaning required to prevent risk of fire or contamination. Again, scaffold, disruption & cost. One annual service is recommended to comply with regulations such as COSHH. Are there any decontamination costs? Specialist decontamination may be required. None. Can fumes be drawn back into the workplace? Yes. Through windows or vents. Fumes are captured by highly efficient filters Could there be disputes with my neighbours? Yes. Over hazardous fumes and odours. Not applicable. Fume Extractor Selector Guide SOLDERING & ELECTRONICS MANUFACTURING Arm Extraction, Cabinets & Cowls Machine Max No. Max No. Max No. Arms 38mm Arms 100mm Cleancabs Tip Extraction Reflow Wave Max No. Soldering Oven Extract Volume Oven Extract Volume Iron Tips Required m3/hr Required m3/hr 1* - - Max No. Cowls FumeCube (inc MAX) 1 or 2 - - 1 or 2 FumeBuster - - 1 or 2 1 or 2 - - - FumeSafe - - - - 3 up to 15 - - 2tiP - - - - 1 or 2 - - 200 3 1 1 2 up to 30 - - 400 6 1 1-2 4 - - - 200i 3 1 1 2 up to 30 - - 200i-HP - - - - up to 50 - - 400i 800i 6 9 1 2 1-2 2-4 4 6 - - - 1500i 12 5 4-8 8 - Below 900 2000i 5000i 15 36 5 10 6-12 12-24 10 20 - Below 1500 Over 1500 Notes: 1. The selection is based on the use of a standard connection kit. 2. A larger extraction machine may be required depending on the layout and the type of fume or dust. 3. * Selective soldering machines only, not suitable for handheld tip extraction. 4. Continuous use may require a machine with larger filtration capacity. Below 1500 Over 1500 5. In some cases more arms/cowls can be used e.g. for non coalescing vapours such as solvents or where airflow valves can be opened and closed. IMPORTANT: Choose a vacuum control machine for Arm and Tip extraction and a volume control machine for other applications. We also have solutions for conformal coating, selective soldering, vapour phase and more, please contact us for more information. LASER ENGRAVING Size of Laser Engraving Machine Light Use Heavy Use* Alpha 200 Alpha 400 Xbase 200 Xbase 400 400i 800i     - -  - - - Small x x  x x x  x     - - - Medium x x x x x    - - x x x x x x    - x x x x x x x x x x x x  x x     Small Medium Large Large Extra large open bed lasers Approximate laser bed sizes: Small - 16”x12”, Medium - 24”x12”, Large - Anything over this.  Normal selection.  Select if extra filter capacity is required and/or additional airflow is required to extract from multiple lasers or heavy duty applications. (-) May also be considered. x Unit not usually specified for application.  Consider if continually lasing acrylic. www.purex.co.uk 800i 2-Tier 1500i 3-Tier (High Dust) (Acrylic) 2000i 5000i Notes: Always select a volume control machine. 1. The selection is based on the use of standard connection kit. 2. * Heavy use includes high proportion of cutting, lasers with a deep bed and constant use. Contact Purex for further advice. 3. The 800i 3 tier unit is designed for use where the application has low dust, but high gas emissions. The 2 tier is designed for applications producing high dust emissions. 4. In applications with extremely high dust emissions, a Cascade inline filter can be considered. -4- purex@purex.co.uk Fume Extractor Selector Guide CODING & MARKING Laser Coding & Marking CPM (Codes per Minute) Good Enclosure FumeCube MAX* 200i 400i Poor Enclosure 800i 2-Tier 800i 3-Tier (High Dust) (High Gas) 1500i 2000i 5000i    - - - - - 500 Machines for Lasing PVC Notes: Always select a volume control machine. 1. The selection is based on the use of a standard connection kit. 2. The 800i 3 tier unit is designed for use where the application has low dust, but high gas emissions. The 2 tier is designed for applications producing high dust emissions. 3. A poor enclosure is where less than 4 sides of the process are enclosed.  Normal selection.  Select if extra filter capacity is required and/or additional airflow is required to extract from multiple lasers or heavy duty applications. (-) May also be considered. x Unit not usually specified for application.  Optional “PVC” machines should be used when lasing onto PVC. * For low wattage lasers or occasional use. Continuous Inkjet Coding & Marking Small Character 200 400 800i Inkjet Printers See Notes    Notes: Always select a volume control machine. There are many different makes and models of inkjet printers available. Please contact Purex or your local representative for advice on which model is correct for particular applications.  Normal selection.  Select if additional airflow is required to extract from multiple inkjet heads or if the controller unit has cooling fans installed. IMPORTANT: • This is a guide only, many factors influence the choice of fume extraction system. For more help and information please contact Purex or your local representative • Purex recommends the use of anti static hose with continuous inkjet printers. WIDE FORMAT PRINTING Printer Model Mimaki Roland Seiko Machine Part No. Machine Type Connection Fittings Manifold Main Filter Pre-Filter Kit JV33-130SP JV33-160SP AdvancedJet AJ-740 VersaUV LEC-300 VersaUV LEC-330 ColorPainter H-74s 230V 080703 080703 0LX4000D 0AL4102 0AL4102 080703 120V 080702 080702 0LX4001D 0AL4103 0AL4103 080702 CaptivairMAX CaptivairMAX 400 Alpha 400 Alpha 400 CaptivairMAX 120309 120309 120188 100019 100019 120303 120311 120312 120299 120090 120089 120314 120313 120313 120322 113800 x 2 113800 x 2 113508 113508 113508 113800 x 2 202260 202269 202269 - ColorPainter H-104s ColorPainter V-64s 080703 0LX4000D 080702 0LX4001D CaptivairMAX 400 120303 120297 120314 120323 x 2 120322 - 113800 x 2 113508 202260 Contact Purex or your local distributor for more information. OTHER APPLICATIONS Dye Sublimation • Laser & Robotic Soldering • Underfill & Conformal Coating • Cleanrooms & Laboratories • Education & Engineering Dentistry • Medical • Welding • Adhesives • Solvents • and more... contact us for more information. www.purex.co.uk -5- purex@purex.co.uk Index Information Accessories Introduction 2-3 Connection Kits Fume Extraction Selector 4-5 Pipe & Duct Solder Fume 4 Arms & Accessories Laser Engraving 4 CleanCabs Coding & Marking 5 Tip Extraction Kits 32-33 Printing 5 Interfacing Cables 34 Plug Leads 35 Replacement Parts 36 Index 6 Digital Machines 200 & 400 8 200i & 400i 9 400i PVC 10 800i 11 1500i & 2000i 12 5000i 13 26-28 29 30-31 31 Appendix Options 37 Pre Filters 38 Main Filters 39 Digital Control System 40-41 Terms & Conditions 42 Filter Matrix 43 Analogue Machines Alpha & Alpha Dust 16 Xbase 17 FumeCube - Std & Max 18-19 FumeSafe 20 2tiP 21 FumeBuster 22 Captivair 23 Cascade Inline Filters 24 www.purex.co.uk -6- purex@purex.co.uk Digital Systems www.purex.co.uk -7- purex@purex.co.uk 200 & 400 1. Model What to specify... 1 2 2. Voltage 3. Volume or Vacuum 4. Pre-filter 5. Main filter 200 3 6. Connection Kit 7. Interfacing Kit 400 Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10% Volume Control Vacuum Control Wattage Frequency Cabinet height (inc castors) Cabinet width (not inc hose) Cabinet depth (not inc hose) Cabinet weight 0LX2100D 080026D 0.46 kW 50Hz / 60 Hz 710 mm 445 mm 528 mm 50 Kg 0LX2101D 081026D 0.47 kW 50Hz / 60 Hz 710 mm 445 mm 528 mm 50 Kg 0LX4000D 080410D 1.30 kW 50Hz / 60 Hz 710 mm 445 mm 528 mm 50 Kg 0LX4001D 080411D 1.37 kW 50Hz / 60 Hz 710 mm 445 mm 528 mm 50 Kg Construction Precision engineered brushed stainless steel units. High performance continuous run brushless motors. Mounted on castors for mobility. 4 Pre-filter Pad Options: F5 Pack of 4 Com Air pr Ava essor ila For ble Th Mod is el Code: 202260 5 Main filter Options: Code: HEPA/Chemical (std) 113505 HEPA/Twin Chemical 113579 HEPA/Chemical Cleanroom 113512 HEPA/Chemical 113505H (Hydrophobic) HEPA 113809 Options: Chemical Chemical Special Chemical (Acidic Fumes) Pleated Bag Solvent Lock* Code: 113508 113662 113505P 113531 113513 Optional Clean Air Cowl - 190040 * IMPORTANT! Must be specified for CIJ printing applications. 6 Connection Hose Kit PUREX PUREX FUME EXTRACTION SYSTEMS FUME EXTRACTION SYSTEMS 5 4 7 3 6 8 1 Process Extractor 7 PAGE 26-28 Machine Interfacing (Optional) 10011010 Your Machine Extractor 10011010 Allows the Purex system to interface with a piece of equipment connected to it. • Start/Stop Control: Extraction unit starts/stops when a connected piece of equipment is switched ON/OFF. • Filter Blocked Warning: A signal is sent to a connected piece of equipment to trigger an alert or to shut it down. • Remote ON/OFF Switch: 5M cable & switch Digital Control System A dedicated control, monitoring and display system unique to Purex fume extractors. All functions are fully automatic, all the user has to do is set the appropriate airflow on installation. The features of this system are designed to: • Lower energy consumption by using variable speed motors and automatic flow control. • Increase filter life by using the optimal extraction rate. • Further protect people by constantly monitoring exhaust emissions. • Interface with other equipment e.g. a laser. • Maintain a constant extraction rate to prevent fume escape or damage to equipment. www.purex.co.uk 2 See PAGE 34 Legend: 1) Air inlet - 80mm safe seal. 2) Pre-filter. 3) Main Filter (HEPA location). † 4) Main Filter (Carbon location). † 5) Clean air returned to workplace. 6) Filter locking handle. 7) Filter identification label. 8) Debris tray. All machines are mounted on four castors for increased mobility. † Standard Filter Only System Features... • Automatic electronic flow control - maintains a constant extraction rate even as the filter blocks • Adjustable airflow • Clear and informative graphic display • Gas and Particle Sensors on the exhaust • Low capital and running costs • Quick change pre-filters deliver longer filter life • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns • Activated carbon filtration removes harmful gas • Simple to install and quiet in operation • Easy to relocate • Precision made from stainless steel -8- Includes: 1 x Main filter 4 x Pre-filter pads 1 x Connection Kit 1 x Power cable Accessories Please see the accessories section at the back of this brochure. purex@purex.co.uk 200i & 400i 1. Model What to specify... 1 2 2. Voltage 3. Volume or Vacuum 200i 3 4. Pre-filter 5. Main filter 200i-HP 6. Connection Kit 7. Interfacing Kit 400i Voltage 230V ±10% 120V ±10% 230V ±10% 230V ±10% 120V ±10% Volume Control Vacuum Control Wattage Frequency Cabinet height (inc castors) Cabinet width (not inc hose) Cabinet depth (not inc hose) Cabinet weight 0LX2110D 080026iD 0.46 kW 50Hz / 60 Hz 1070 mm 465 mm 528 mm 60 Kg 0LX4010D 080410iD 1.30 kW 50Hz / 60 Hz 1070 mm 465 mm 528 mm 60 Kg 0LX4013D 080411iD 1.37 kW 50Hz / 60 Hz 1070 mm 465 mm 528 mm 60 Kg Construction Precision engineered brushed stainless steel units. High performance continuous run brushless motors. Mounted on castors for mobility. 4 0LX2121D 081026iD 0.47 kW 50Hz / 60 Hz 1070 mm 465 mm 528 mm 60 Kg 080050iD 1.30 kW 50Hz / 60 Hz 1070 mm 465 mm 528 mm 60 Kg Labyrinth Pre-filter Options: (Pack of 2): F6 (std) F8/F9 Composite 5 Com Air pr Ava essor ila For ble Th Mod is el Code: 202268 202271 Main filter Options: HEPA/Chemical (std) HEPA+/Chemical (200i-HP)* HEPA/Twin Chemical or HEPA/Twin Chemical HEPA/Chemical Cleanroom* Chemical 6 Code: 113505 113811 113579 113669 113512 113508 Options: Code: HEPA/Chemical (Hydrophobic)113505H Chemical Special 113662 Chemical (Acidic Fumes) 113505P Pleated Bag 113531 HEPA 113809 * Use in combination with 202271 Connection Hose Kit Optional Clean Air Cowl - 190040 PUREX FUME EXTRACTION SYSTEMS 5 4 7 3 6 Process Extractor 7 1 PAGE 26-28 Machine Interfacing (Optional) 10011010 Your Machine Extractor 10011010 Allows the Purex system to interface with a piece of equipment connected to it. • Start/Stop Control: Extraction unit starts/stops when a connected piece of equipment is switched ON/OFF. • Filter Blocked Warning: A signal is sent to a connected piece of equipment to trigger an alert or to shut it down. • Remote ON/OFF Switch: 5M cable & switch Digital Control System A dedicated control, monitoring and display system unique to Purex fume extractors. All functions are fully automatic, all the user has to do is set the appropriate airflow on installation. The features of this system are designed to: • Lower energy consumption by using variable speed motors and automatic flow control. • Increase filter life by using the optimal extraction rate. • Further protect people by constantly monitoring exhaust emissions. • Interface with other equipment e.g. a laser. • Maintain a constant extraction rate to prevent fume escape or damage to equipment. www.purex.co.uk See PAGE 34 Legend: 1) Air inlet - 80mm safe seal. 2) Pre-filter. 3) Main Filter (HEPA location). † 4) Main Filter (Carbon location). † 5) Clean air returned to workplace. 6) Filter locking handle. 7) Filter identification label. All machines are mounted on four castors for increased mobility. † Standard Filter Only System Features... • Automatic electronic flow control - maintains a constant extraction rate even as the filter blocks • Adjustable airflow • Clear and informative graphic display • Gas and Particle Sensors on the exhaust • Low capital and running costs • Quick change patented Labyrinth pre-filters deliver longer filter life • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns • Activated carbon filtration removes harmful gas • Simple to install and quiet in operation • Easy to relocate and precision made from stainless steel -9- 2 Includes: 1 x Main filter 2 x Labyrinth Pre-filters 1 x Connection Kit 1 x Power cable Accessories Please see the accessories section at the back of this brochure. purex@purex.co.uk 400i PVC What to specify... 1 1. Model 2. Voltage 3. Pre-filter 4. Main filter 5. Connection Kit 6. Interfacing Kit 400i PVC 2 Voltage 230V ±10% 120V ±10% Volume Control 0PV4010D 0PV4013D Wattage 1.30 kW 1.37 kW Frequency 50Hz / 60 Hz 50Hz / 60 Hz Cabinet height (inc castors) 1181 mm 1181 mm Cabinet width (not inc hose) 465 mm 465 mm Cabinet depth (not inc hose) 528 mm 528 mm Cabinet weight 70 Kg 70 Kg Special • High chemical resistance epoxy coating on all inner surfaces, painted onto SSPC-SP6 prepared stainless steel for maximum adhesion of coating. Construction • Polypropylene protective pads and bushings protect the filter mechanisms and epoxy coating from wear. • Corrosion resistant polymer fasteners and caps protect the door hinges and casters. Door catches and grounding wire mounted externally to avoid corrosion. 3 Labyrinth Pre-filter Options: F8/F9 Composite (Pack of 2) Chemical Absorbant Pad (Pack of 4) Com Air pr Ava essor ila For ble Th Mod is el Code: 202271 200261 Note: Both Pre-filter and pads are required. The absorbant pad should be replaced when the Labyrinth filter is replaced or sooner if required. 4 Main filter Options: HEPA/PVC Chemical (std) Code: 113498 Optional Clean Air Cowl - 190040 PUREX PUREX FUME EXTRACTION SYSTEMS FUME EXTRACTION SYSTEMS 5 5 Connection Hose Kit 7 4 3 6 Process Extractor 6 Please choose 100043C connection kit from PAGE26 Machine Interfacing (Optional) 10011010 Your Machine Extractor 10011010 Allows the Purex system to interface with a piece of equipment connected to it. • Start/Stop Control: Extraction unit starts/stops when a connected piece of equipment is switched ON/OFF. • Filter Blocked Warning: A signal is sent to a connected piece of equipment to trigger an alert or to shut it down. • Remote ON/OFF Switch: 5M cable & switch Digital Control System A dedicated control, monitoring and display system unique to Purex fume extractors. All functions are fully automatic, all the user has to do is set the appropriate airflow on installation. The features of this system are designed to: • Lower energy consumption by using variable speed motors and automatic flow control. • Increase filter life by using the optimal extraction rate. • Further protect people by constantly monitoring exhaust emissions. • Interface with other equipment e.g. a laser. • Maintain a constant extraction rate to prevent fume escape or damage to equipment. www.purex.co.uk See PAGE 34 1 Legend: 1) Air inlet - 80mm safe seal. 2) Pre-filter. 3) Main Filter (HEPA location). 4) Main Filter (Carbon location). 5) Clean air returned to workplace. 6) Filter locking handle. 7) Filter identification label. - All machines are mounted on four castors for increased mobility. - An absorbant pad is also supplied to fit under the Labyrinth filter System Features... • Automatic electronic flow control - maintains a constant extraction rate even as the filter blocks • Adjustable airflow • Clear and informative graphic display • Gas and Particle Sensors on the exhaust • Low capital and running costs • Quick change patented Labyrinth pre-filters deliver longer filter life • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns • Activated carbon filtration removes harmful gas • Simple to install and quiet in operation • Easy to relocate and precision made from stainless steel - 10 - 2 Includes: 1 x Main filter 2 x Labyrinth Pre-filters 4 x Absorbant Pads 1 x Connection Kit 1 x Power cable Accessories Please see the accessories section at the back of this brochure. purex@purex.co.uk 800i 1. Model What to specify... 1 2 2. Voltage 3. Volume or Vacuum 4. Pre-filter 5. Main filter 800i - 2 Tier 3 6. Connection Kit 7. Interfacing Kit 800i - 3 Tier Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10% Volume Control Vacuum Control Wattage Frequency Cabinet height (inc castors) Cabinet width (not inc hose) Cabinet depth (not inc hose) Cabinet weight 080502D 080505D 2.60 kW 50Hz / 60 Hz 1143 mm 571 mm 670 mm 80 Kg 080503D 080507D 2.74 kW 50Hz / 60 Hz 1143 mm 571 mm 670 mm 80 Kg 080501D 080504D 2.60 kW 50Hz / 60 Hz 1143 mm 571 mm 670 mm 90 Kg 080500D 080506D 2.74 kW 50Hz / 60 Hz 1143 mm 571 mm 670 mm 90 Kg Construction Precision engineered brushed stainless steel units. High performance continuous run brushless motors. Mounted on castors for mobility. 4 Labyrinth Pre-filter Options: (Pack of 2) (2-Tier) F6 (std) F8/9 Composite* 202280 202272 (3-Tier) F8/9 Composite (std)* 202273 5 Code: PVC Vers Ava ion ilab le PVC Options: Code: Chemical Absorbant 200262 Pad (Pack of 4) *Use F8/F9 Labyrinth bags for PVC Com Air pr Ava essor ila For ble Th Mod is el Main filter Options: (2-Tier) (3-Tier) HEPA/Chemical (std) or.. HEPA/Twin Chemical or.. HEPA/Chemical Cleanroom† HEPA (std) and.. Chemical (std) or.. Solvent Lock* Code: 113652 113660 113658 113650 113651 113667 † Use in combination with 202272 Optional Clean Air Cowl - 190039 * Must be specified for CIJ printing applications. PUREX PUREX FUME EXTRACTION SYSTEMS FUME EXTRACTION SYSTEMS 6 Connection Hose Kit (Optional) Extractor 7 PAGE 26-28 For PVC applications please contact us. 10011010 Extractor 10011010 Allows the Purex system to interface with a piece of equipment connected to it. • Start/Stop Control: Extraction unit starts/stops when a connected piece of equipment is switched ON/OFF. • Filter Blocked Warning: A signal is sent to a connected piece of equipment to trigger an alert or to shut it down. • Remote ON/OFF Switch: 5M cable & switch Digital Control System A dedicated control, monitoring and display system unique to Purex fume extractors. All functions are fully automatic, all the user has to do is set the appropriate airflow on installation. The features of this system are designed to: • Lower energy consumption by using variable speed motors and automatic flow control. • Increase filter life by using the optimal extraction rate. • Further protect people by constantly monitoring exhaust emissions. • Interface with other equipment e.g. a laser. • Maintain a constant extraction rate to prevent fume escape or damage to equipment. www.purex.co.uk FUME EXTRACTION SYSTEMS FUME EXTRACTION SYSTEMS 7 6 B A 2 800i 2-Tier Machine Interfacing (Optional) Your Machine PUREX PUREX 4 3 1 Process 5 See PAGE 34 Legend: 1) Air inlet - 100mm safe seal. 2) Pre-filter. 3) Main Filter (HEPA location). † 4) Main Filter (Carbon location). † 5) Clean air returned to workplace. 6) Filter locking handle. 7) Filter identification label. All machines are mounted on four castors for increased mobility. † Standard Filter Only System Features... • Automatic electronic flow control - maintains a constant extraction rate even as the filter blocks • Adjustable airflow • Clear and informative graphic display • Gas and Particle Sensors on the exhaust • Low capital and running costs • Quick change patented Labyrinth pre-filters deliver longer filter life • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns • Activated carbon filtration removes harmful gas • Simple to install and quiet in operation • Easy to relocate and precision made from stainless steel - 11 - 800i 3-Tier A) HEPA filter B) Carbon filter Includes: 1 x Main filter (2-tier) 2 x Main filters (3-tier) 2 x Labyrinth Pre-filters 1 x Power cable (no plug) Accessories Please see the accessories section at the back of this brochure. purex@purex.co.uk 1500i & 2000i 1. Model What to specify... 1 2 2. Voltage 3. Volume or Vacuum 4. Pre-filter 5. Main filter 1500i 3 6. Connection Kit 7. Interfacing Kit 2000i Voltage 230V ±10% 120V ±10% 400V 3ph + N 220V 3ph Volume Control Vacuum Control Wattage Frequency Cabinet height (inc castors) Cabinet width (not inc hose) Cabinet depth (not inc hose) Cabinet weight (inc filters) 0LX1510D 021820iD 1.5 kW 50Hz / 60 Hz 1400 mm 725 mm 726 mm 150 Kg 0LX1511D 021821iD 1.5 kW 50Hz / 60 Hz 1400 mm 725 mm 726 mm 150 Kg 0LX2010D 022120iD 3.0 kW 50Hz / 60 Hz 1400 mm 725 mm 726 mm 150 Kg 0LX2011D 022121iD 3.0 kW 50Hz / 60 Hz 1400 mm 725 mm 726 mm 150 Kg Construction Precision engineered brushed stainless steel units. High performance continuous run brushless motors. Mounted on castors for mobility. 4 Labyrinth Pre-filter Options: F6 (std) F8/F9 Composite* 5 Code: 111037 111099 PVC Vers Ava ion ilab le PVC Options: Code: Chemical Absorbant 200281 Pad (Pack of 4) *Use F8/F9 Labyrinth bags for PVC Com Air pr Ava essor ila For ble Th Mod is el Main filter Options: HEPA/Chemical (std) HEPA/Twin Chemical HEPA/Chemical Cleanroom* Chemical Code: 110615 110614 110632 110610 Optional Clean Air Cowl - 640002 * Use in combination with 111099 6 PUREX PUREX FUME EXTRACTION SYSTEMS FUME EXTRACTION SYSTEMS Connection Hose Kit (Optional) Process Extractor 7 10011010 Extractor 10011010 Allows the Purex system to interface with a piece of equipment connected to it. • Start/Stop Control: Extraction unit starts/stops when a connected piece of equipment is switched ON/OFF. • Filter Blocked Warning: A signal is sent to a connected piece of equipment to trigger an alert or to shut it down. • Remote ON/OFF Switch: 5M cable & switch Digital Control System A dedicated control, monitoring and display system unique to Purex fume extractors. All functions are fully automatic, all the user has to do is set the appropriate airflow on installation. The features of this system are designed to: • Lower energy consumption by using variable speed motors and automatic flow control. • Increase filter life by using the optimal extraction rate. • Further protect people by constantly monitoring exhaust emissions. • Interface with other equipment e.g. a laser. • Maintain a constant extraction rate to prevent fume escape or damage to equipment. www.purex.co.uk 7 6 3 1 PAGE 26-28 For PVC applications please contact us. Machine Interfacing (Optional) Your Machine 5 4 See PAGE 34 Legend: 1) Air inlet - 150mm safe seal. 2) Pre-filter. 3) Main Filter (HEPA location). † 4) Main Filter (Carbon location). † 5) Clean air returned to workplace. 6) Filter locking handle. 7) Filter identification label. All machines are mounted on four castors for increased mobility. † Standard Filter Only System Features... • Automatic electronic flow control - maintains a constant extraction rate even as the filter blocks • Adjustable airflow • Clear and informative graphic display • Gas and Particle Sensors on the exhaust • Low capital and running costs • Quick change patented Labyrinth pre-filters deliver longer filter life • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns • Activated carbon filtration removes harmful gas • Simple to install and quiet in operation • Easy to relocate and precision made from stainless steel - 12 - 2 Includes: 1 x Main filter 1 x Labyrinth Pre-filter 1 x Power cable (no plug) Accessories Please see the accessories section at the back of this brochure. purex@purex.co.uk 5000i 1. Model What to specify... 1 2 2. Voltage 3. Volume or Vacuum 4. Pre-filter 5. Main filter 6. Connection Kit 7. Interfacing Kit 5000i 3 Voltage 400V 3ph + N 220V 3ph Volume Control Vacuum Control Wattage Frequency Cabinet height (inc castors) Cabinet width (not inc hose) Cabinet depth (not inc hose) Cabinet weight (inc filters) 0LX5550D 044250D 7.5 kW 50Hz / 60 Hz 1804 mm 1250 mm 892 mm 400 Kg 0LX5551D 044251D 7.5 kW 50Hz / 60 Hz 1804 mm 1250mm 892 mm 400 Kg Construction Precision engineered brushed stainless steel units. High performance continuous run brushless motors. Mounted on castors for mobility. 4 Pre-filter 1 - Labyrinth (Side Inlet) Options: Code: F8/F9 Composite* 111006 Tagged (std) F8 111072 PVC Vers Ava ion ilab le PVC Options: Code: Chemical Absorbant 200312 Pad (Pack of 4) *Use F8/F9 Labyrinth bags for PVC Com Air pr Ava essor ila For ble Th Mod is el 2 - Pleated Bag (Rear Inlet) Options: Code: Pre-filter Pad 200310 (Pack of 4) and... Pleated Bag Filter 111144 5 Main filter Options: HEPA (std) and... Chemical (std) or... Pleated Bag Code: 110633 110627 110645 Options: Code: Heavy Duty Chemical 110624 For applications where high levels of solvent are used or when lasing acrylic. (!) Please note the 5000i requires 2 main filters. Use 111006 in cleanroom applications. 6 Connection Hose Kit (Optional) 5 PUREX PUREX FUME EXTRACTION SYSTEMS FUME EXTRACTION SYSTEMS 1 2a 7 4 6 2b Process Extractor 7 Machine Interfacing (Optional) 10011010 Your Machine Extractor 10011010 Allows the Purex system to interface with a piece of equipment connected to it. • Start/Stop Control: Extraction unit starts/stops when a connected piece of equipment is switched ON/OFF. • Filter Blocked Warning: A signal is sent to a connected piece of equipment to trigger an alert or to shut it down. • Remote ON/OFF Switch: 5M cable & switch Digital Control System A dedicated control, monitoring and display system unique to Purex fume extractors. All functions are fully automatic, all the user has to do is set the appropriate airflow on installation. The features of this system are designed to: • Lower energy consumption by using variable speed motors and automatic flow control. • Increase filter life by using the optimal extraction rate. • Further protect people by constantly monitoring exhaust emissions. • Interface with other equipment e.g. a laser. • Maintain a constant extraction rate to prevent fume escape or damage to equipment. www.purex.co.uk 7 Call Purex or your local distributor for more information. See PAGE 34 Legend: 1) Air inlet (Left or Rear) - 200mm safe seal. 2) Pre-filter. 3) Main Filter (HEPA location). † 4) Main Filter (Carbon location). † 5) Clean air returned to workplace. 6) Filter locking handle. 7) Filter identification label. Note: 2a) Prefilter pad 2b) Pleated Bag Filter Alternatively a Labyrinth filter can be supplied. All machines are mounted on four castors for increased mobility. † Standard Filter Only System Features... • Automatic electronic flow control - maintains a constant extraction rate even as the filter blocks • Adjustable airflow • Clear and informative graphic display • Gas and Particle Sensors on the exhaust • Low capital and running costs • Quick change patented Labyrinth or standard pre-filters deliver longer filter life • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns • Activated carbon filtration removes harmful gas • Simple to install and quiet in operation • Easy to relocate and precision made from stainless steel - 13 - 3 6 Includes: 2 x Main filters and 1 x Labyrinth Pre-filter or 4 x Pre-filter pads with 1 x Pleated Bag Filter 1 x Power cable (no plug) Accessories Please see the accessories section at the back of this brochure. purex@purex.co.uk www.purex.co.uk - 14 - purex@purex.co.uk Analogue Systems www.purex.co.uk - 15 - purex@purex.co.uk Alpha & Alpha Dust What to specify... 1 1. Model 2. Voltage 3. Pre-filter 4. Main filter 5. Connection Kit 200 2 6. Interfacing Kit 400 Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10% Alpha-Vacuum Control 0AL2102 0AL2103 0AL4102 0AL4103 Alpha Dust-Vacuum Control Wattage Frequency Cabinet height (inc castors) Cabinet width (not inc hose) Cabinet depth (not inc hose) Cabinet weight 0.14 kW 50Hz / 60 Hz 885 mm 465 mm 430 mm 55 Kg 0.107 kW 50Hz / 60 Hz 885 mm 465 mm 430 mm 55 Kg 0AL4136 0.24 kW 50Hz / 60 Hz 885 mm 465 mm 430 mm 55 Kg 0AL4137 0.255 kW 50Hz / 60 Hz 885 mm 465 mm 430 mm 55 Kg Construction Precision engineered brushed stainless steel units. High performance continuous run brushless motors. Mounted on castors for mobility. 3 Labyrinth Pre-filter Standard Alpha Options: (Pack of 2) F6 (std) F8/F9 Composite Code: 202269 202274 4 Dust Version Options: (Pack of 2) F6 (std) F8/F9 Composite Com Air pr Ava essor ila For ble Th Mod is el Code: 202268 202271 Main filter Options: HEPA/Chemical (std) HEPA/Twin Chemical or HEPA/Twin Chemical HEPA/Chemical Cleanroom* HEPA HEPA/Chemical (Hydrophobic) Code: 113505 113579 113669 113512 113809 113505H Options: Chemical Chemical Special Chemical (Acidic Fumes) Pleated Bag Code: 113508 113662 113505P 113531 * Use in combination with 202274 7 NOTE: No main filters are required for the dust version. PUREX FUME EXTRACTION SYSTEMS 5 Connection Hose Kit 4 3 6 Process Extractor 6 PAGE 26-28 10011010 Your Machine Extractor 10011010 Allows the Purex system to interface with a piece of equipment connected to it. • Start/Stop Control: Extraction unit starts/stops when a connected piece of equipment is switched ON/OFF. • Filter Blocked Warning: A signal is sent to a connected piece of equipment to trigger an alert or to shut it down. • Remote ON/OFF Switch: 5M cable & switch Controls Visual and Audible Filter Blocked Warning Alerts the operator when a filter starts to block so that a replacement filter can be acquired and downtime can be avoided. LED Filter Status Green = Filter OK Yellow = Filter nearly full Red = Filter full, replacement required Interface with other equipment e.g. a laser optional. www.purex.co.uk 2 1 Machine Interfacing (Optional) See PAGE 34 Legend: 1) Air inlet - 80mm safe seal. 2) Pre-filter. 3) Main Filter (HEPA location). 4) Main Filter (Carbon location). 5) Clean air returned to workplace. 6) Filter locking handle. 7) Filter identification label. All machines are mounted on four castors for increased mobility. The Alpha Dust has a labyrinth bag only. System Features... • Automatic electronic flow control - maintains a constant extraction rate even as the filter blocks • Adjustable airflow • VariColour filter blocked warning system • Low capital and running costs • Quick change, patented Labyrinth pre-filters deliver longer filter life • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns • Activated carbon filtration removes harmful gas • Simple to install and quiet in operation • Easy to relocate • Precision made from stainless steel - 16 - 5 PUREX FUME EXTRACTION SYSTEMS 1 Alpha Dust Includes: 1 x Main filter 2 x Labyrinth pre-filters 1 x Connection Kit 1 x Power cable Note: Alpha Dust does not contain a main filter. Accessories Please see the accessories section at the back of this brochure. purex@purex.co.uk Xbase What to specify... 1 1. Model 2. Voltage 3. Pre-filter 4. Main filter 5. Connection Kit 200 2 6. Interfacing Kit 400 Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10% Vacuum Control Wattage Frequency Cabinet height (inc castors) Cabinet width (not inc hose) Cabinet depth (not inc hose) Cabinet weight 0AL2106 0.14 kW 50Hz / 60 Hz 705 mm 707 mm 691 mm 80 Kg 0AL2107 0.107 kW 50Hz / 60 Hz 705 mm 707 mm 691 mm 80 Kg 0AL4104 0.24 kW 50Hz / 60 Hz 705 mm 707 mm 691 mm 80 Kg 0AL4107 0.255 kW 50Hz / 60 Hz 705 mm 707 mm 691 mm 80 Kg Construction Precision engineered brushed stainless steel units. High performance continuous run brushless motors. Mounted on castors for mobility. 3 Labyrinth Pre-filter Options: (Pack of 2) F8/F9 Composite 4 Code: 202275 Main filter Options: HEPA/Chemical (std) HEPA CSA Com Air pr Ava essor ila For ble This Mod el Code: 110545 113585 Storage Area 5 7 Connection Hose Kit 5 4 3 Process Extractor 6 6 1 PAGE 26-28 Machine Interfacing (Optional) 10011010 Your Machine Extractor 10011010 Allows the Purex system to interface with a piece of equipment connected to it. • Start/Stop Control: Extraction unit starts/stops when a connected piece of equipment is switched ON/OFF. • Filter Blocked Warning: A signal is sent to a connected piece of equipment to trigger an alert or to shut it down. • Remote ON/OFF Switch: 5M cable & switch Controls Visual and Audible Filter Blocked Warning Alerts the operator when a filter starts to block so that a replacement filter can be acquired and downtime can be avoided. LED Filter Status Green = Filter OK Yellow = Filter nearly full Red = Filter full, replacement required Interface with other equipment e.g. a laser optional. www.purex.co.uk 2 Legend: 1) Air inlet. - 80mm safe seal. 2) Pre-filter. 3) Main Filter (HEPA location). 4) Main Filter (Carbon location). 5) Clean air returned to workplace. 6) Filter locking handle. 7) Filter identification label. All machines are mounted on four castors for increased mobility. See PAGE 34 System Features... • Automatic electronic flow control - maintains a constant extraction rate even as the filter blocks • Adjustable airflow • VariColour filter blocked warning system • Low capital and running costs • Quick change, patented Labyrinth pre-filters deliver longer filter life • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns • Activated carbon filtration removes harmful gas • Simple to install and quiet in operation • Easy to relocate • Precision made from stainless steel - 17 - Includes: 1 x Main filter 2 x Labyrinth pre-filters 1 x Connection Kit 1 x Power cable Accessories Please see the accessories section at the back of this brochure. purex@purex.co.uk FumeCube What to specify... 1 1. Single or Dual Arm System 2. Voltage 3. Pre-filter Single Arm System 2 4. Main filter 6. Interfacing Kit Dual Arm System Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10% Vacuum Control Wattage Frequency Cabinet height Cabinet width (not inc hose) Cabinet depth (not inc hose) Cabinet weight (inc filters) 072066 0.14 kW 50Hz / 60 Hz 366 mm 308 mm 294 mm 17 Kg 072067 0.107 kW 50Hz / 60 Hz 366 mm 308 mm 294 mm 17 Kg 072065 0.14 kW 50Hz / 60 Hz 366 mm 308 mm 294 mm 17 Kg 072068 0.107 kW 50Hz / 60 Hz 366 mm 308 mm 294 mm 17 Kg Construction Precision engineered brushed stainless steel units. High performance continuous run brushless motors. Quick and simple to relocate. 3 Pre-filter Pad Options: F5 Pack of 4 (std) F6 Pack of 4 F8/F9 Pack of 4 4 Code: 200225 200226 200316 Main filter Options: Code: HEPA/Chemical (std) 110536 Chemical 110537 Chemical Special 110544 HEPA/Chemical Cleanroom* 110538 6 Options: Solvent Lock Code: 110543 * Use in combination with 200316 Note: FumeCubes sold prior to December 2008 may require different filters. Please contact your local distributor for advice. Machine Interfacing (Optional) 10011010 Your Machine Extractor 10011010 Allows the Purex system to interface with a piece of equipment connected to it. • Start/Stop Control: Extraction unit starts/stops when a connected piece of equipment is switched ON/OFF. • Filter Blocked Warning: A signal is sent to a connected piece of equipment to trigger an alert or to shut it down. • Remote ON/OFF Switch: 5M cable & switch 1 2 3 4 7 See PAGE 34 PUREX FUME EXTRACTION SYSTEMS 5 Single arm system supplied with: 1 x Filter + pre-filter pad 1 x 51mm x 2m flexible hose [black] 2 x Connecting cuffs [black] 1 x Clamped bracket 1 x 38mm stainless steel flexible arm and valve 1 x 38mm pen nib nozzle & 1 x conical cowl. Dual arm system supplied with: 1 x Filter + pre-filter pad 2 x 51mm x 2m flexible hose [black] 4 x Connecting cuffs [black] 2 x Clamped bracket 2 x 38mm stainless steel flexible arm and valve 2 x 38mm pen nib nozzle and 2 x conical cowl. Controls Visual and Audible Filter Blocked Warning Alerts the operator when a filter starts to block so that a replacement filter can be acquired and downtime can be avoided. LED Filter Status Green = Filter OK Yellow = Filter nearly full Red = Filter full, replacement required Interface with other equipment e.g. a laser optional. www.purex.co.uk Legend: 1) Air inlet - 57mm ID - 62mm OD 2) Pre-filter. 3) Main Filter (HEPA location). 4) Main Filter (Carbon location). 5) Clean air returned to workplace. 7) Filter identification label. In cleanroom filters, positions 3&4 are reversed. System Features... • Automatic electronic flow control - maintains a constant extraction rate even as the filter blocks • Adjustable airflow • VariColour filter blocked warning system • Low capital and running costs • Quick change pre-filters deliver longer filter life • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns • Activated carbon filtration removes harmful gas • Simple to install and quiet in operation • Easy to relocate • Precision made from stainless steel - 18 - Includes: 1 x Main filter 4 x Pre-filter pad 1 or 2 Arm Kit 1 x Power cable Accessories Please see the accessories section at the back of this brochure. purex@purex.co.uk FumeCube MAX 1. Voltage What to specify... 2. Pre-filter 3. Main filter 4. Kits 5. Interfacing Kit Machine Only 1 Voltage 230V ±10% 120V ±10% Vacuum Control Wattage Frequency Cabinet height Cabinet width (not inc hose) Cabinet depth (not inc hose) Cabinet weight (inc filters) 072115 0.14 kW 50Hz / 60 Hz 493 mm 314 mm 330 mm 14 Kg 072116 0.107 kW 50Hz / 60 Hz 493 mm 314 mm 330 mm 14 Kg 2 NEW Pre-filter Labyrinth Pre-Filter (All models) Description: Code: F8/F9 Composite 111124 3 Main filter Main Filters Description: HEPA/Chemical (std) Chemical Legend: 1) Air inlet - 80mm safe seal. 2) Prefilter. 3) Main Filter (HEPA location). 4) Main Filter (Carbon location). 5) Clean air returned to workplace. 7) Filter identification label. 1 2 3 4 7 Construction - Precision engineered brushed stainless steel units. Quick and simple to relocate. Code: 110507 110504 PUREX FUME EXTRACTION SYSTEMS 5 4 Hose and Arm Kits Option 1 Description: 51mm hose kit (3m) Code: 100032 Option 2 Single 38mm arm kit (Screw Fixing) 1 x Arm Kit (Screw Fix) 100294 or 1 x Arm Kit (Clamp Fix) 100295 1 x 80mm to 51mm reducer 550287 Option 3 Dual 38mm arm kit 2 x Arm Kit (Screw Fix) or 2 x Arm Kit (Clamp Fix) 1 x Dual Manifold Assembly 3m 2m 2m 100294 100295 120093C PUREX FUME EXTRACTION SYSTEMS PUREX PUREX FUME EXTRACTION SYSTEMS FUME EXTRACTION SYSTEMS Option 1 - Hose Kit 5 Allows the Purex system to interface with a piece of equipment connected to it. Option 3 - 38mm Dual Arm Kit Machine Interfacing (Optional) • Start/Stop Control: Extraction unit starts/stops when a connected piece of equipment is switched ON/OFF. • Filter Blocked Warning: A signal is sent to a connected piece of equipment to trigger an alert or to shut it down. • Remote ON/OFF Switch: 5M cable & switch - See PAGE 34 Controls Visual and Audible Filter Blocked Warning Alerts the operator when a filter starts to block so that a replacement filter can be acquired and downtime can be avoided. LED Filter Status Green = Filter OK Yellow = Filter nearly full Red = Filter full, replacement required Interface with other equipment e.g. a laser optional. www.purex.co.uk Option 2 - 38mm Single Arm Kit System Features... • Automatic electronic flow control - maintains a constant extraction rate even as the filter blocks • Adjustable airflow • VariColour filter blocked warning system • Low capital and running costs • Quick change, patented Labyrinth pre-filters deliver longer filter life • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns • Activated carbon filtration removes harmful gas • Simple to install and quiet in operation • Easy to relocate • Precision made from stainless steel - 19 - Includes: 1 x Main filter 1 x Labyrinth Pre-Filter 1 x Power cable purex@purex.co.uk FumeSafe™ 1. Model What to specify... 3. Pre-filter 4. Main filter 3-15 Tip Fume Extraction Unit 1 Voltage 230V ±10% or 120V ±10% Vacuum Control Wattage Frequency Cabinet height Cabinet width (not inc hose) Cabinet depth (not inc hose) Cabinet weight (inc filters) Construction 072200 0.45 kW 50Hz / 60 Hz 493 mm 471 mm 430 mm 26 Kg Stainless Steel Construction Precision engineered brushed stainless steel units. High performance continuous run brushless motors. Quick and simple to relocate. 3 Auto Sensing Dual Voltage Blower Works Anywhere in the World! Replacement Pads Pre Filter Pre Filter Options: F8/F9 Pack of 4 Code: 200098 Exhaust Filter Options: Single Code: 200053 Exhaust Filter 4 Replacement Main filter Options: HEPA/Chemical (std) Chemical or Chemical Special HEPA/Chemical Cleanroom Solvent Lock Code: 110531 110532 110542 110533 110541 1 2 3 4 6 Pipe kit (100165) includes 32mm Ø: 6 x 1.5M x 32mm pipe (3 pre drilled) 4 x 90º bends 2 x Swept T’s 4 x Straight connectors 2 x End caps Code: 500050 500080 500100 500060 500120 PUREX FUME EXTRACTION SYSTEMS 5 Legend: 1) Air inlet - 80mm safe seal. 2) Prefilter. 3) Main Filter (HEPA location). 4) Main Filter (Carbon location). 5) Clean air returned to workplace. 6) Filter identification label. 41mm Hose x 1.5m Connector Hose Clips Also includes machine to pipe connector hose Code - 100170 PUREX FUME EXTRACTION SYSTEMS Supplied with 3 universal iron kits - 300001 Controls Visual and Audible Filter Blocked Warning Alerts the operator when a filter starts to block so that a replacement filter can be acquired and downtime can be avoided. www.purex.co.uk Controls & System Features... • Speed Control • Dual voltage brushless blower • Low capital and running costs • Quick change pre-filters deliver longer filter life • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns • Activated carbon filtration removes harmful gas • Simple to install and quiet in operation • Easy to relocate • Precision made from stainless steel • Filter blocked alarm and LED - 20 - Includes: 1 x Main filter 1 x Pre-filter pad 1 x Exhaust filter 1 x Power cable 1 x Connection kit 1 x Pipework kit 3 x Universal iron kits Accessories Please see the accessories section at the back of this brochure. purex@purex.co.uk 2tiP 1. Model What to specify... 3. Pre-filter 4. Main filter 2 Tip Fume Extraction Unit 1 Voltage 230V ±10% Vacuum Control Wattage Frequency Cabinet height Cabinet width (not inc hose) Cabinet depth (not inc hose) Cabinet weight (inc filters) Construction 072120 0.135 kW 50Hz / 60 Hz 275 mm 286 mm 291 mm 9.8 Kg Stainless Steel Construction Precision engineered brushed stainless steel units. High performance continuous run brushless motors. Quick and simple to relocate. 3 Replacement Pre-filter Pad Options: F5 Pack of 4 (std) F6 Pack of 4 4 Code: 200225 200226 Replacement Main filter Options: HEPA/Chemical (std) Code: 110507 1 2 3 4 6 41mm Hose x 1.5m Hose Clips PUREX Connector for 2 x silicone tube FUME EXTRACTION SYSTEMS 5 PUREX FUME EXTRACTION SYSTEMS Supplied with connection kit Options: Iron kits (Pg 32-33) Controls & System Features... • Run LED • Speed Control • Low capital and running costs • Quick change pre-filters deliver longer filter life • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns • Activated carbon filtration removes harmful gas • Simple to install and quiet in operation • Easy to relocate • Precision made from stainless steel www.purex.co.uk Legend: 1) Air inlet - 38mm ID - 40mm OD 2) Prefilter. 3) Main Filter (HEPA location). 4) Main Filter (Carbon location). 5) Clean air returned to workplace. 6) Filter identification label. Includes: 1 x Main filter 1 x Pre-filter pad 1 x Power cable 1 x Connection kit 1 x End cap Accessories Please see the accessories section at the back of this brochure. - 21 - purex@purex.co.uk FumeBuster What to specify... 1. Voltage 2. Pre-filter 3. Main filter 4. Capture Kit (For one or two stations) Machine Only 1 Voltage 230V ±10% 115V ±10% Vacuum Control Wattage Frequency Cabinet height (inc castors) Cabinet width (not inc hose) Cabinet depth (not inc hose) Cabinet weight (inc filters) 070362 0.3 kW 50Hz 350 mm 425 mm 415 mm 25 Kg 070363 0.3 kW 60 Hz 350 mm 425 mm 415 mm 25 Kg Construction Precision engineered brushed stainless steel units. High performance continuous run brushless motors. Quick and simple to relocate. 2 Pre-filter Pad Options: F5 Pack of 4 (std) F8/F9 Pack of 4 3 Code: 200314 200098 Main filter Options: Code: HEPA/Chemical (std) 110531 Chemical 110532 or Chemical Special 110542 HEPA/Chemical Cleanroom* 110533 4 Solvent Lock 110541 * Use in combination with 200098 Capture Kit (Optional) 1 x 1.2m x 75mm Ø flexible arm with 2 x 75mm couplings (120707) + 1 x Conical cowl (840114) 1 Code: 100181 7 2 3 4 PUREX FUME EXTRACTION SYSTEMS 1 x 1.5m x 75mm Ø flexible hose with 2 x 75mm couplings (100185) + 1 x Anti-static plenum cowl (black) (120702) 5 Code: 100182 Legend: 1) Air inlet - 75mm ID - 77mm OD 2) Prefilter. 3) Main Filter (HEPA location). 4) Main Filter (Carbon location). 5) Clean air returned to workplace. 7) Filter identification label. 1 x 1.5m x 75mm Ø flexible hose with 2 x 75mm couplings (100185) + 1 x Cleancab extraction cabinet (840155) 75mm Code: 100183 Controls Visual and Audible Filter Blocked Warning Alerts the operator when a filter is blocked so that a replacement filter can be acquired. LED Filter Status Green = Filter OK Red = Filter full, replacement required www.purex.co.uk In cleanroom filters, positions 3&4 are reversed. System Features... • Audible and visual filter blocked alert • Low capital and running costs • Quick change pre-filters deliver longer filter life • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns • Activated carbon filtration removes harmful gas • Simple to install and quiet in operation • Easy to relocate • Precision made from stainless steel - 22 - Includes: 1 x Main filter 4 x Pre-filter pad 1 x Port blank (530430) 1 x Power cable Accessories Please see the accessories section at the back of this brochure. purex@purex.co.uk capTIVaIr What to specify... Voltage Model Captivair Max 2 Voltage 230V ±10% 120V ±10% Vacuum Control Wattage Frequency Cabinet height (inc castors) Cabinet width (not inc hose) Cabinet depth (not inc hose) Cabinet weight (inc filters) 080703 080702 0.155 kW 50 Hz 691 mm 851 mm 591 mm 100 Kg 0.280 kW 60 Hz 691 mm 851 mm 591 mm 100 Kg capTIVaIr MAX Legend: 1) Air inlet 4 x 48mm ID - 51mm OD 4 x 98mm ID - 102mm OD 4) Main Filter (Carbon location). 5) Clean air returned to workplace. TM 1 4 MAX All machines are constructed of coated steel. 3 2 PUREX FUME EXTRACTION SYSTEMS 1 1 0 5 Main filter (Included) Description: Chemical (refillable) Refill for 113800 Code: 113800 113805 (!) Please note the CaptivairMAX requires 2 main filters. Printer Model Mimaki Roland Seiko Machine Part No. Machine Type Connection Fittings Manifold Main Filter Pre-Filter Kit JV33-130SP JV33-160SP AdvancedJet AJ-740 VersaUV LEC-300 VersaUV LEC-330 ColorPainter H-74s 230V 080703 080703 0LX4000D 0AL4102 0AL4102 080703 120V 080702 080702 0LX4001D 0AL4103 0AL4103 080702 CaptivairMAX CaptivairMAX 400 Alpha 400 Alpha 400 CaptivairMAX 120309 120309 120188 100019 100019 120303 120311 120312 120299 120090 120089 120314 120313 120313 120322 113800 x 2 113800 x 2 113508 113508 113508 113800 x 2 202260 202269 202269 - ColorPainter H-104s ColorPainter V-64s 080703 0LX4000D 080702 0LX4001D CaptivairMAX 400 120303 120297 120314 120323 x 2 120322 - 113800 x 2 113508 202260 Contact Purex or your local distributor for more information. Captivair units are available for other printer models, please contact Purex or your local distributor for further information. Features... • Captures fumes at source • Reduces fumes escaping into the workplace • Promotes a more pleasant working environment • Can help reduce headaches and nausea caused by fumes • Helps prevent fumes escaping into neighbouring buildings and rooms • Bespoke kits for each printer model • Can aid compliance with health and safety regulations www.purex.co.uk System Features... • Visual filter blocked alert • Low capital and running costs • Activated carbon filtration of ink vapour • Simple to install and quiet in operation • Easy to relocate - 23 - Includes: 2 x Main filters 1 x Power cable purex@purex.co.uk Inline Filter Units What to specify... Pre-filter Connection Kit Spark Arrestor Cascade 1 Part number 890180 890241 Cabinet height (inc castors) 1063 mm 1063 mm Cabinet width (not inc hose) 430 mm 430 mm Cabinet depth (not inc hose) 430 mm 430 mm Cabinet weight (inc filters) 30 Kg 30 Kg Note: Vacuum or Volume The Cascade Box is fitted with a silicone vacuum sensing tube. Not Applicable. The tube should be connected to the inlet on all vacuum machines e.g. Xbase, Alpha and Digital Tip and Arm Applications. It should not be connected on volume machines. 2 Cascade Pre-filter Description: Needlefelt Cascade Code: 111107 or Spark Arrestor Description: Supplied with a collection tray Description: Labyrinth F8/F9 Composite Code: 111117 Cascade Version Shown 3 Connection Hose Kit Process Extractor 1 1 1 1 2 x x x x x 1M of 80mm hose 100-80mm reducer 80mm coupling 100mm coupling 70-90mm hose clips Code: 100184 1 Legend: 1) Air inlet - 80mm safe seal 2) Pre-filter. 3) Support Straps 4) Hooks for Support Straps 5) Exhaust 6) Drop Out Box 1 4 2 3 5 Cascade Version Labyrinth Version Inline Filter The Cascade Box acts as an additional prefilter to capture particles in applications where large amounts are produced. The filter can be emptied when full and the operator can periodically shake the filter to increase filter life. • Removes large particles from the process air • Extends the life of the filters in the fume extractor • Can be used on problematic applications where large quantities of dust are produced • Filter can be seeded to help deal with sticky particles • Filter can be emptied and shaken to prolong life* www.purex.co.uk Cabinet mounted on four castors for increased mobility. 5 6 Spark Arrestor Air Inlet can be ordered in various positions • The use of this unit means the operator does not have to buy a new, larger fume extraction machine • Low capital and running costs • Simple to install and easy to relocate • Precision made from stainless steel * cascade filter only Spark Arrestor This inline unit is used to prevent sparks entering the extraction machine. It works by extinguishing sparks against metal surfaces and collecting hot materials in a drop out box. - 24 - Includes: 1 x Cascade filter or 1 x Labyrinth filter or 1 x Drop out box 1 x Connection kit Accessories Please see the accessories section at the back of this brochure. purex@purex.co.uk Accessories www.purex.co.uk - 25 - purex@purex.co.uk Connection Kits PUREX MACHINE INLET DIAMETERS • • • • 40mm - 2tiP 57mm - FumeCube 75mm - FumeBuster 80mm - 200, 400, 200i, 400i, 200i-HP, 400iPVC Alpha, Alpha Dust, Xbase, FumeCube Max, FumeSafe • 100mm - 800i • 150mm - 1500i,2000i • 200mm - 5000i 32mm Connect to 32mm diameter pipe/port ??mm Diameter of pipe/port 80mm 1.5m 1 1 2 2 FUME EXTRACTION SYSTEMS x x x x Connect to 50mm diameter pipe/port 80-34mm reducer 1.5m x 41mm flexible hose Half straight connector 35-50mm hose clips Connect to 50mm diameter pipe/port or Purex valve Purex machine inlet diameter 80mm 2.0m Code: 100180 PUREX FUME EXTRACTION SYSTEMS 1 x 80-53.5mm reducer 1 x 2m x 57mm flexible hose 2 x 45-60mm hose clips 2.0m 1.5m 50mm Length of hose 50mm Code: 100170 PUREX ??mm ?.?m 3.0m (Anti Static) Code: 1 1 1 2 PUREX FUME EXTRACTION SYSTEMS x x x x 80mm 50mm Twin Head AntiStatic 100026 80mm These are bespoke kits. An example is shown on the left. Contact us for more information. earth strap 6mm 80mm to 51mm reducer 3m x 50mm antistatic hose 51mm antistatic cuffs 3.0m 50mm 2.0m Code: Connect to 50mm diameter pipe/port or Purex valve 2.0m 57mm 50mm 120117 Connect to 50mm diameter pipe/port or Purex valve 1 x 2m x 51mm flexible hose 2 x 51mm cuffs FUME EXTRACTION SYSTEMS Connect to 50mm diameter pipe/port or Purex valve 6.0m PUREX FUME EXTRACTION SYSTEMS 6.0m www.purex.co.uk Code: 100032 PUREX FUME EXTRACTION SYSTEMS 1 x 80-51mm reducer 1 x 3m x 51mm flexible hose 2 x 51mm cuffs 3.0m PUREX 50mm 80mm 3.0m 80mm 50mm Type Code: Std 100043 PVC* 100043C Connect to 50mm diameter pipe/port or Purex valve 1 x 80-51mm reducer 1 x 6m x 51mm flexible hose 2 x 51mm cuffs * coated reducer suitable for PVC applications 6.0m (Dual Manifold) 80mm Code: 100039* PUREX FUME EXTRACTION SYSTEMS (Use with 100043 or 100043C) 1 x dual manifold assembly(120093C) 1 x 6m x 51mm flexible hose 2 x 51mm cuffs * also suitable for PVC applications. 6.0m - 26 - purex@purex.co.uk Connection Kits 50mm 50mm 6.0m (Extension) 50mm Code: 100037* Code: 100019 1 x 50mm coupling 1 x 6m x 51mm flexible hose 2 x 51mm cuffs 1 x 80-51mm reducer 1 x 2m x 51mm flexible hose 2 x 51mm cuffs Connect to 50mm diameter pipe/port * also suitable for PVC applications. LASER XBASE 2.0m 50mm Connect to 50mm diameter pipe/port 80mm 3.0m 75mm Code: 100185 1 x 80-53 mm reducer 1 x 3m x 57mm flexible hose 2 x 45-60mm hose clips FUME EXTRACTION SYSTEMS 2 x 85-75mm reducer 1 x 1.5m x 75mm flexible hose Connect to 75mm diameter port 1.5m PUREX 3.0m FUME EXTRACTION SYSTEMS 80mm Connect to 80mm diameter pipe/port 75mm 1.5m Code: 120285 PUREX 80mm 2.0m 80mm 3.0m Code: 80mm 120299 Connect to 80mm diameter pipe/port 1 x 80mm female coupling 1 x 3m x 82mm flexible hose 2 x 70-90mm hose clips PUREX FUME EXTRACTION SYSTEMS 80mm 1.3m Code: 120293 1 x 80mm female coupling 2 x 70-90mm hose clips 1 x 1.3m x 82mm flexible hose PUREX FUME EXTRACTION SYSTEMS LASER XBASE 3.0m 1.3m 100mm Connect to 100mm diameter pipe/port 100mm 100mm 3.0m Code: 100107* Connect to 100mm diameter pipe/port 1 x 3m x 100mm flexible hose 2 x 90-120mm hose clips PUREX FUME EXTRACTION SYSTEMS * suitable for PVC 3.0m Code: 120270 1 x 100mm female coupling 1 x 1.5m x 100mm flexible hose 2 x 90-120mm hose clips PUREX FUME EXTRACTION SYSTEMS 1.5m 100mm 80mm 2.3m Connect to 100mm diameter pipe/port 0.3m 100mm 1.5m PUREX FUME EXTRACTION SYSTEMS 100mm Code: 120288 1 2 1 1 1 x x x x x 80mm 2.0m (Dual) Code: 120297 80mm female coupling 70-90mm hose clips 2m x 82mm flexible hose 100-80mm reducer 0.3m x 100mm flexible hose 2 x 90-120mm hose clips PUREX FUME EXTRACTION SYSTEMS 2.0m Connect to 100mm diameter pipe/port 3 1 2 2 4 x x x x x 80mm female coupling 80mm equal tee 100-80mm reducer 2m x 100mm flexible hose 90-120mm hose clips 2.0m 2.0m www.purex.co.uk - 27 - purex@purex.co.uk Connection Kits ??mm ??mm ?.?m 100mm 80mm 1.3m Code: 120292 1 2 1 1 1 2 0.3m Diameter of pipe/port Length of hose 100mm Purex machine inlet diameter 3.0m (Dual) 100mm 1 1 2 4 PUREX FUME EXTRACTION SYSTEMS x x x x 1.3m XBASE 100mm Connect to 100mm diameter pipe/port Code: 120291 Connect to 100mm diameter pipe/port LASER Connect to 100mm diameter pipe/port 100mm female coupling 100mm equal tee 3m x 102mm flexible hose 90-120mm hose clips 125mm 80mm 3.0m 1 1 1 1 1 2 PUREX FUME EXTRACTION SYSTEMS x x x x x x 1 1 2 2 2 2 2 2 FUME EXTRACTION SYSTEMS 3.0m x x x x x x x x 150mm female coupling 150mm equal tee 150 female couplings 150-100mm reducers 90-120mm hose clips 3m x 102mm flexible hose 90-120mm hose clips 100mm female couplings 100mm 3.0m Code: Connect to 125mm diameter pipe/port 80mm female coupling 100-80mm reducer 3m x 100mm flexible hose 125-100mm reducer 125mm female coupling 90-120mm hose clips 150mm Code: 120287 PUREX 125mm Code: 100171 Connect to 125mm diameter pipe/port 80mm female coupling 70-90mm hose clips 1m x 82mm flexible hose 100-80mm reducer 0.3m x 100mm flexible hose 90-120mm hose clips 3.0m (Dual) 3.0m 3.0m x x x x x x 1 1 1 2 PUREX FUME EXTRACTION SYSTEMS x x x x 100172 100mm female coupling 125-100mm reducers 3m x 125mm flexible hose 135-160mm hose clips 3.0m 150mm 150mm 1.5m Code: PUREX 1 1 1 2 FUME EXTRACTION SYSTEMS Connect to 150mm diameter pipe/port x x x x 150mm 80mm 3.3m 120280 Code: 150mm female coupling 150mm male coupling 1.5m x 150mm flexible hose 135-160mm hose clips Connect to 150mm diameter pipe/port 0.3m 0.3m 1 2 1 1 1 2 1 1 2 PUREX FUME EXTRACTION SYSTEMS 3.0m x x x x x x x x x 120289 80mm female coupling 70-90mm hose clips 3m x 82mm flexible hose 100-80mm reducer 0.3m x 100mm flexible hose 90-120mm hose clips 150-100mm reducer 0.3m x 150mm flexible hose 135-160mm hose clips 1.5m 150mm 100mm 3.25m 200mm Code: 120294 Connect to 150mm diameter pipe/port PUREX FUME EXTRACTION SYSTEMS 3.0m www.purex.co.uk 1 1 4 2 2 2 4 x x x x x x x Connect to 200mm diameter pipe/port 100mm female coupling 100mm equal tee 90-120mm hose clips 3m x 100mm flexible hose 150-100mm reducers 0.25m x 150mm flexible hose 135-165mm hose clips - 28 - 200mm 1.0m Code: SPECIAL PUREX FUME EXTRACTION SYSTEMS 1 1 1 2 x x x x 200mm female coupling 200mm male coupling 1m x 200mm flexible hose 200mm hose clips purex@purex.co.uk Pipe & Duct Plastic Pipe Ø 32mm Plastic Pipe Ø 50mm Plastic Pipe Ø 82mm 3.0m straight pipe 500050 - Grey 500055 - Black ABS 3.0m straight pipe 520000 - Grey 520300 - Black ABS 3.0m straight pipe 530110 - Grey Straight connector 500060 - Grey 500065 - Black ABS Straight connector 520020 - Grey 520330 - Black ABS Straight connector 530170 45º bend 500070 - Grey 45º bend 520070 - Grey 45º bend single socket 530180 90º bend 500080 - Grey 500090 - Black ABS 90º bend 520080 - Grey 520130 - Black ABS 90º bend single socket 530190 Swept ‘T’ 500100 - Grey 500110 - Black ABS Swept ‘T’ 520120 - Grey 520320 - Black ABS Swept ‘T’ 530210 End blank 500120 - Grey 500130 - Black ABS End blank 520170 Socket plug 530220 Pipe clip 500180 Pipe clip 520180 Pipe clip 530120 Pipe reducer (50-32mm) 520150 50 32 Pipe reducer (82-50mm) 530200 82 50 82mm Strap boss 530160 50mm Boss adaptor 530150 Steel Duct Ø 100mm Steel Duct Ø 150mm Steel Duct Ø 200mm 3.0m spiral pipe 540100 3.0m spiral pipe 540300 3.0m spiral pipe 540600 90º bend 540133 90º bend 540345 90º bend 540620 45º bend 540130 45º bend 540333 45º bend 540622 30º bend 540129 30º bend 540328 Equal ‘T’ 540145 Equal ‘T’ 540337 Equal ‘T’ 540630 End cap 540161 End cap 540400 End cap 540402 ‘U’ bracket saddle 540190 ‘U’ bracket saddle 540450 ‘U’ bracket saddle 540891 Butterfly valve 540185 Butterfly valve 540440 Butterfly valve 540439 Pipe reducer (100mm-80mm) 540150 Pipe reducer (150mm-100mm) 540382 Pipe reducer (200mm-150mm) 540640 ENERGY Valve - Alternating Shut Off (100mm) 540686 www.purex.co.uk ENERGY Valve - Alternating Shut Off (200mm) 540684 - 29 - purex@purex.co.uk Arms & Accessories 38mm Stainless Steel Flexible Arm Kit For Purex Airflow Valves Includes: 1 x 38mm x 1m stainless steel flexible arm with fixed pen nib nozzle 1 x Support collar and valve 1 x Screwed bench bracket 1 x 51mm x 2m flexible hose with 2 connecting cuffs Includes: 1 x 38mm x 1m stainless steel flexible arm (includes 1 x Support collar and valve) 1 x Clamped bench bracket 1 x Pen-nib nozzle (38mm ID) 1 x Conical cowl (95mm ID) 1 x 51mm x 2m flexible hose with 2 connecting cuffs Code: 100294 Code: 100295 Replacement parts available if required. Replacement parts available if required. (Additional Fittings) Clear hood cowl (265 x 310mm) Code: 840160 Pen Nib Nozzle (38mm ID) Code: 840170 Delta cowl (192 x 5mm inlet) Code: 840182 Conical Cowl (95mm ID) Code: 840190 Screwed bench bracket Code: 840200 Clamped bench bracket Code: 120180 Wall bracket Code: 840210 Bench support collar and valve Code: 840048 Plenum cowl Anti static polycarbonate (black) Includes 57mm airflow valve Code: 120703 Plenum cowl Anti static polycarbonate (clear) Includes 57mm airflow valve Code: 120704 Max W x L 300 x 400mm L W 38mm Stainless Steel Flexible Arm For Push Fit Valves Build This is a high quality stainless steel replacement arm to fit plastic push fit valves. 1 x 38mm x 1m stainless steel flexible arm 1 x Pen-nib nozzle (38mm ID) or 1 x Conical cowl (38mm ID) 1 x Tapered fitting Pen Nib Type Code: 120143 Upgrade to Purex Conical Cowl Type Code: 120144 50mm Stainless Steel Flexible Arm Kit For Purex Airflow Valves Includes: 1 x 50mm x 1m stainless steel flexible arm with fixed conical cowl 1 x Support collar and valve 1 x Clamped bench bracket 1 x 51mm x 2m flexible hose with 2 connecting cuffs Includes: 1 x 50mm x 1m stainless steel flexible arm with square end 1 x Support collar and valve 1 x Clamped bench bracket 1 x 51mm x 2m flexible hose with 2 connecting cuffs Includes: 1 x 50mm x 1m stainless steel flexible arm with clear hood cowl & cuff 1 x Support collar and valve 1 x Clamped bench bracket 1 x 51mm x 2m flexible hose with 2 connecting cuffs Code: 100297 Code: 100298 Code: 100299 Replacement parts available if required. www.purex.co.uk - 30 - purex@purex.co.uk Arms & Accessories CleanCab Enclosed Extraction Unit 627mm Clear Hood with Exhaust Point 365mm 305mm 455mm 512mm 150mm Base Unit 615mm 860mm Depth = 510mm Complete Kit Includes: Base Open hood 57mm Airflow valve Code: 840150 50mm Includes: Base Open hood 75mm Exhaust port Code: 840155 75mm Hood Only 50mm 75mm Includes: Downdraught base + Insert Perforated steel plate Open hood 75mm Exhaust port Code: 840164 Base Only Includes: Open hood 57mm Airflow valve Code: 840159 Includes: Base Code: Includes: Open hood 75mm Exhaust port Code: 840171 Includes: Downdraught base + insert Perforated steel plate 75mm Exhaust port Code: 840161 840152 Includes: Open hood Code: 840151 Connection kits with 51mm cuffs are suitable for 57mm valves - for 75mm exhaust port use kit 100185 Clean Air Feed Free Clean Air! • Purex machines produce very clean air from the exhaust so why not use it? • This replacement exhaust cowl can be used to supply clean air to equipment such as lasers, ovens and more... Machine Range: Code: 200/400, 200i/400i 190040 800i 190039 1500i/2000i 640002 Dual Inlet Manifold Connect two hose to one machine. Manifold: Aluminium Manifold Coated Aluminium Manifold for corrosive fumes. (1 x 80mm to 2 x 50mm inlets) Large Flexible Arms - Call Digital 400 machines and above only. 100mm = Code: 120172 Other diameters please call. www.purex.co.uk Code: 120093 120093C Compressors 30 PSI / 2.1 bar Compressor: Free standing Integrated * Code: 100284 100283 * 200i/400i/Alpha/Xbase - 31 - purex@purex.co.uk Tip Kits & Accessories Universal - Soldering Iron Kit Allows an extraction tube to be fitted to most common soldering irons. 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 1 1 5 1 1 x x x x x 1 1 1 1 1 1 x x x x x x 1.5m x 6mm ID x 1.5mm wall clear silicone hose (560030) screw in adaptor (8mm hose, M10) (580010) 8mm Ø hose clips (580525) universal iron stand (830007) soldering iron stand (830008) 1 x cup standard iron (830000) 1 x cup metcal iron (830005) extraction tube clip weller (830040) extraction tube clip metcal/mini weller (830050) extraction tube strap universal (830051) 6mm Ø x 100mm extraction tube weller (830110) 6mm Ø x 135mm extraction tube metcal (830112) 6mm Ø x 225mm extraction tube universal (830135) 4 13 5 12 11 2 6 8 9 Code: 300001 7 1 10 3 Specific - Soldering Iron Kits Allows an extraction tube to be fitted to specific soldering irons. Metcal iron kit 1 x extraction tube clip 1 x 6mm Ø x 135mm extraction tube 1 x 1.5m x 6mm ID x 1.5mm wall clear silicone hose 5 x hose clips Universal iron stand 1 x screw in adaptor (M10) Antex/Ersa iron kit 1 x extraction tube clip 1 x extraction tube strap 1 x 6mm Ø x 225mm extraction tube 1 x 1.5m x 6mm ID x 1.5mm wall clear silicone hose 5 x hose clips Universal iron stand 1 x screw in adaptor (M10) Mini Weller iron kit 1 x extraction tube clip 1 x 6mm Ø x 135mm extraction tube 1 x 1.5m x 6mm ID x 1.5mm wall clear silicone hose 5 x hose clips 1 x soldering iron stand 1 x cup 1 x screw in adaptor (M10) Standard Weller/RS/ Adcola iron kit 1 x extraction tube clip 1 x 6mm Ø x 100mm extraction tube 1 x 1.5m x 6mm ID x 1.5mm wall clear silicone hose 5 x hose clips 1 x soldering iron stand 1 x cup 1 x screw in adaptor (M10) www.purex.co.uk 100075 830050 830112 560030 580525 830007 580010 100085 830050 830051 830135 560030 Large Weller iron adaptor kit 100070 1 x extraction tube clip 1 x 7mm Ø x 150mm extraction tube 1 x 1.5m x 6mm ID x 1.5mm wall clear silicone hose 5 x hose clips 1 x soldering iron stand 1 x cup 1 x screw in adaptor (M10) 830041 830115 560030 580525 830008 830002 580010 Pace iron adaptor kit 100072 580525 830007 580010 1 x extraction tube strap 1 x 6mm Ø x 100mm extraction tube 1 x 1.5m x 6mm ID x 1.5mm wall clear silicone hose 5 x hose clips 1 x soldering iron stand 1 x cup 1 x screw in adaptor (M10) 100065 Hakko iron adaptor kit 100030 830050 830112 560030 580525 830008 830005 580010 1 x 6mm Ø x 225mm extraction tube 1 x 1.5m x 6mm ID x 1.5mm wall clear silicone hose 5 x hose clips 1 x screw in adaptor (M10) 1 x extraction tube strap 830051 830110 560030 580525 830008 830002 580010 830136 560030 580525 580010 830051 100060 830040 830110 560030 580525 830008 830000 580010 - 32 - purex@purex.co.uk Tip Kits & Accessories These optional kits allow the user to quickly and simply detach the soldering iron from the extraction system. The options are: • To detach the iron from the main pipework. • To detach the iron from trunking on the bench. • To detach the iron from an ON/OFF tap. Use with Soldering Iron Kits shown on previous page. Optional - Quick Release Kit 1 x Adaptor 8mm hose 1/4BSP 1 x 8mm red blank 1 x Adaptor tube 8mm x 65mm (580070) (580130) (580300) Connect extraction tube from soldering iron Code: 100100 PIPE Optional - Trunking Connector Kit (Quick Release) 1 1 1 1 1 1 x Adaptor tube 8mm x 65mm x 8mm red blank x Trunking connector (8mm) x 8mm Connector hose stem x 1.5m x 6mm ID x 1.5mm wall clear silicone hose x screw in adaptor (8mm hose, M10) (580300) (580130) (580190) (580210) (560030) (580010) Connect extraction tube from soldering iron Code: 100090 Trunking PIPE Optional - ON/OFF Tap Kit (Quick Release) 1 1 1 1 1 2 1 4 x 8mm Connector hose stem x 0.04m x 8mm ID x 2mm wall clear silicone hose x ON/OFF tap bracket x ON/OFF tap x 1m x 13mm flexihose x Hose clip 15mm x Adaptor 12mm hose 3/8BSP x Screws (580210) (560060) (580090) (590078) (570000) (580500) (580035) Connect extraction tube from soldering iron PIPE Code: 300002 Optional - Tube Cleaning Brushes Tube cleaning brushes 5mm bronze 830200 Airflow meter 5-50 l/min 10-100 l/min 330200 330201 www.purex.co.uk - 33 - purex@purex.co.uk Machine Interfacing 4 way Mini Bulgin 6 way Bulgin 4 1 2 Code: 105097 5 way XLR Neutric 1 2 3 (5M cable) Code: 105105 3 1 6 3 4 2 5 4 (5M cable) Code: 105103 5 (5M cable) ALARM PINS 1 + 2 = VOLT FREE ALARM OUTPUT CONTACTS ALARM PINS 1 + 4 = VOLT FREE ALARM OUTPUT CONTACTS ALARM PINS 1 + 4 = VOLT FREE ALARM OUTPUT CONTACTS REMOTE START VOLT FREE CONTACTS REQUIRED TO OPERATE PIN 3 = REMOTE START INPUT SIGNAL PIN 4 = +12V DC REMOTE START VOLTAGE SIGNAL REQUIRED TO OPERATE PIN 2+3 (LINKED) = REMOTE START INPUT SIGNAL PIN 5 = 0V DC REMOTE START VOLT FREE CONTACTS REQUIRED TO OPERATE PIN 3 = REMOTE START INPUT SIGNAL PIN 5 = +12V DC PIN 2 + 6 = NOT USED 9 way D-type 9 way D-type 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 Code: 105106 (5M cable) 9 way D-type Code: 105107 (5M cable) 1 2 3 4 5 6 7 8 9 Code: 105104 (5M cable) ALARM NO ALARM OUTPUT ALARM PIN 3 = +12VDC / +24VDC ALARM OUTPUT ALARM PINS 1 + 2 = VOLT FREE ALARM OUTPUT CONTACTS REMOTE START VOLTAGE SIGNAL REQUIRED TO OPERATE PIN 2 = 0V DC PIN 3 = +12VDC / +24VDC REMOTE START INPUT SIGNAL REMOTE START VOLTAGE SIGNAL REQUIRED TO OPERATE PIN 1 = REMOTE START INPUT SIGNAL PIN 9 = 0V DC REMOTE START VOLT FREE CONTACTS REQUIRED TO OPERATE PIN 3 = REMOTE START INPUT SIGNAL PIN 4 = +12V DC 6 way Lumberg 4 5 Code: 105096 3 6 7 way Lumberg 1 2 2 ALARM PINS 1 + 6 = VOLT FREE ALARM OUTPUT CONTACTS PINS 3 + 4 = VOLT FREE ALARM OUTPUT CONTACTS REMOTE START VOLTAGE SIGNAL REQUIRED TO OPERATE PIN 5 = +12VDC / +24VDC REMOTE START INPUT SIGNAL PIN 2 = 0V DC INPUT Code: 105098 6 7 3 1 (5M cable) 5 4 (5M cable) Code: 105108 ALARM PINS 3 + 4 = VOLT FREE ALARM OUTPUT CONTACTS REMOTE START VOLTAGE SIGNAL REQUIRED TO OPERATE PIN 1 = +12VDC / +24VDC REMOTE START INPUT SIGNAL PIN 2 = 0V DC INPUT PIN 5 + 6 = LINKED PIN 7 = NOT USED Code: 105114 Remote ON/OFF Switch No Connector (5M cable) Yellow and green wires = remote start stop Volt free contacts required to close these wires to start (+12VDC signal) Red and blue wires = alarm signal Output via a set of volt free contacts inside Purex extractor (5M cable) Now you can easily switch your Purex fume extractor on or off from up to 5m away. This is particulary useful if your fume extractor is tucked away under a bench or in a cupboard where it cannot easily be accessed. This feature is also useful if the work you do is not continuous e.g. intermittent hand soldering as you will be saving energy by turning the extractor off. IMPORTANT: Failure to follow the wiring instructions above or hard wiring other cables to your Purex machine will invalidate any warranty and may damage your machine. www.purex.co.uk - 34 - purex@purex.co.uk Power Plug Options Note: A plug will be supplied to match the destination region on the order. E.g. an order to go to the UK will be supplied with a UK plug unless you request otherwise. FumeCube (inc MAX), FumeBuster, FumeSafe, 2tiP and Captivair Are supplied with a 2m long detachable cable with a choice of plug. USA/ASIA 120V UK Europe No Plug Bare wire only. Code: 410125 Code: 410100 Code: 410127 Code: 410120 200/400, 200i/400i, 400iPVC, Alpha, Xbase Are supplied with a 5m long detachable cable with a choice of plug. USA/ASIA 120V Code: 410160 USA/ASIA 230V Code: 410161 Australia UK Code: 410162 Europe Code: 410163 No Plug Bare wire only. Code: 410164 Code: 410165 800i, 1500i, 2000i, 5000i Are factory fitted with a 5m long cable without a plug. Electrical installations should only be carried out by a qualified person. www.purex.co.uk - 35 - purex@purex.co.uk Replacement Parts PART Blower 230V Blower 120V 200 400 200i 200i-HP 400i 400i PVC 800i - 2 Tier 800i - 3 Tier 1500i 2000i 5000i Alpha 200 Alpha 400 Xbase 200 Xbase 400 FumeCube (inc Max) FumeBuster FumeSafe 2tiP Captivair Max 300593 300595 300593 300596 300595 300595 300595 x 2 300595 x 2 Blower 230V/120V Blower 220V/400V PCB Digital Volume PCB Digital Vacuum 300592 300594 300592 400001 400001 400001 300594 300594 300594 x 2 300594 x 2 400001 400001 400001 400001 400001 400001 400001 400000 400000 400000 400000 400000 300603 300612 300615 300170 300172 300170 300172 300170 300161 300174 300173 300174 300173 300174 300162 PCB Analogue 400000 400000 400000 400000 400000 FMU Inverter Filter Monitor 230V/120V Unit 400440 400440 400440 400440 400440 400440 400440 400440 400440 400406 400440 400440 Inverter 220V Inverter 400V 400394 400393 400396 400439 400048 400048 400048 400048 400048 400049 300618 300575 300588 400005 400007 300589 When ordering PCBs please supply the machine serial number and connection kit used. Replacement Fuses Code: 410246 Code: 410276 Code: 410271 (For 200, 200i - 120V) & (400, 400i & 400iPVC - 230V) (For 200, 200i - 230V) & (Alpha, Xbase - 230V & 120V) (For 400, 400i & 400iPVC - 120V) Replacement Manuals Code: 822005 Digital Manual Code: 822006 Analogue Manual Code: 822001 Captivair Manual Download from www.purex.co.uk www.purex.co.uk - 36 - purex@purex.co.uk Options Supplied as Standard Machine Selection 1 Specifying the correct model is vitally important to ensure the extraction rate is sufficient and filtration is optimal. Volume or Vacuum Digital machines come with the choice of vacuum or volume sensing. Vacuum sensing is for tip and arm applications. Volume sensing is for laser and machine processing.† Pre-filter 4 2 5 The pre-filter protects the main filter from premature blockage. A wide choice of pre-filter combinations are available from Purex depending on your application. 3 Voltage All machines are available in a variety of voltages to cater for different regions of the world. Main Filter 6 Connection Kit Connect the extractor to pipe work or to another machine such as a laser or reflow oven.* A wide choice of main filter combinations are available from Purex depending on your application. PUREX FUME EXTRACTION SYSTEMS Optional Additional Filtration 7 Interface Kit The Purex machine can control or be controlled by another machine such as a laser or reflow oven. Options include: ON/OFF control and filter blocked warnings. Accessories Accessories include arm, tip and pipework kits. Some applications may require additional filter capacity, for example the Cascade filter can extend the life of other filters in problematic applications. 10 8 101010101 11 PUREX FUME EXTRACTION SYSTEMS 9 Remote ON/OFF Switch your Purex fume extractor on/off from up to 5m away. This is particulary useful if your fume extractor is tucked away under a bench where it cannot easily be accessed. Installation Correct installation is essential to aid compliance with health and safety regulations and to protect your people and process. 101010101 PUREX FUME EXTRACTION SYSTEMS 12 LEV Testing LEV testing is also essential to aid compliance with health and safety regulations and to protect your people and process. † Digital machines offer volume or vacuum sensing, all other machines are vacuum sensing only. *Not all machines are supplied with a connection kit as standard, please check the individual product page for details. For more help and information please contact Purex or your local representative www.purex.co.uk - 37 - purex@purex.co.uk Pre-Filters Pre-filters are designed to capture larger particles before they can enter the main HEPA filter. Without pre-filters, the life of the main filter would be much shorter. ✘ ✔ A variety of media and designs are available to allow Purex extractors to be used in a wide range of processes. Large Particles from the Process Block the HEPA Filter Pads Large Particles from the Process are Held in the Pre-Filter Labyrinth Patented Labyrinth pre-filters Pad pre-filter • Extends the life of the main filter by capturing larger particles before they reach the HEPA filter • Fits neatly under the main filter • Graduated fibre matrix delivers excellent particle capture capacity • Ideal for low volume applications or where small amounts of particles are produced • Extends the life of the main filter by capturing larger particles before they reach the HEPA filter • Fits neatly under the main filter in integral Purex extractors • Graduated fibre matrix delivers excellent particle capture capacity - up to 20 times more than a standard filter • Ideal for medium-high volume applications • Can deal with sticky or moisture laden particles • Composite material available for extra filter life and filtration down to 0.5 micron • Contains the particles inside for clean and simple disposal Pleated Bag Cascade Process Cascade Extractor PUREX FUME EXTRACTION SYSTEMS Particles & Gas From Process Large Particles Removed Pleated bag pre-filter Cascade heavy duty inline filter Extends the life of the main filters by capturing larger particles Used in Purex 5000i machines Provides additional particle capturing capacity Ideal for processes where large amounts of particles are produced • Contains the particles inside for clean and simple disposal • Extends the life of the pre-filter by capturing larger particles • Fits between the process and the Purex machine • Provides additional particle capturing capacity • Ideal for processes where large amounts of particles are produced • Can be emptied and reused • Can be powder seeded for extra life in difficult applications • Contains the particles inside for clean and simple disposal • • • • www.purex.co.uk - 38 - Clean Air purex@purex.co.uk Main Filters Purex use specialised combinations of filter media to capture particles, gases and vapours generated by industrial processes such as laser engraving, laser marking, hand and machine soldering, ink jet printing and many others. Each filter has a unique serial number and is individually tested and certified to ensure performance and safety. Purex HEPA (High Efficiency Particulate Air) filter elements are precision manufactured from a pleated material that incorporates reinforcing strips which separate the pleats and help prevent airflow vibration or collapse. Additionally, air equalisation plates are used between the layers of media to further reinforce the filter housing and to distribute the airflow across the filter to ensure all of the filter media is used. Typical Filter Chemical Adsorbs a wide variety of gases and vapours. Chemical Airflow HEPA/Chemical Filters small particles @ 99.997% down to 0.3 microns in size and adsorbs a wide variety of gases and vapours HEPA/Twin Chemical Chemical HEPA Airflow Filters small particles @ 99.997% down to 0.3 microns in size and adsorbs a wide variety of gases and vapours particularly from rubber engraving or acidic gas applications. HEPA/CSA HEPA/PVC Chemical Chemical1 Chemical2 HEPA Airflow CSA Heavy duty filter for laser engraving rubber. Filters small particles @ 99.997% down to 0.3 microns in size and adsorbs gases and corrosive vapours generated when PVC is laser processed. Chemical HEPA Chemical Airflow HEPA Adsorbs a wide variety of gases and vapours. Filters small particles @ 99.997% down to 0.3 microns in size. Chemical Chemical HEPA Airflow Airflow HEPA Airflow HEPA/Chemical Cleanroom Adsorbs a wide variety of gases and vapours and filters small particles @ 99.997% down to 0.3 microns in size. Specially designed for use in cleanrooms. (Use F8/F9 prefilters.) www.purex.co.uk HEPA Chemical Solvent Lock Adsorbs gases and vapours generated by ink jet printing and certain solvent applications. Airflow Pleated Bag Chemical Airflow - 39 - Filters small particles from the airstream. Replaces the HEPA filter in certain machines and applications. Pleated Bag Airflow purex@purex.co.uk Digital Control System “The Ultimate in Advanced Control, Monitoring, Performance and Safety Features” Water proof Fascia PUREX Graphic Display Menu Buttons 0 m3/ hr 0 FUME EXTRACTION SYSTEMS 22 οC ON/OFF Switch A dedicated control, monitoring and display system unique to Purex fume extractors. All functions are fully automatic, all the user has to do is set the appropriate airflow on installation. The many features of this system are designed to: • Protect people by constantly monitoring exhaust emissions. • Maintain a constant airflow and lower energy consumption by using variable speed motors which also allow the use of a fully automatic flow control system. • Show the operator at a glance the status of the machine via an advanced graphic display. Target & Actual Airflow (Flow Control) Filter Blocked Monitor 0 m3/ hr Motor Run Icon Gas Safety Sensor 0 Particle Safety Sensor 22 Filter Change Indicators oC Filtered Air Temperature www.purex.co.uk - 40 - purex@purex.co.uk Digital Control System Gas Sensors Particle Sensors Constantly monitors the chemical filters to warn the user when they are nearly saturated. This helps reduce downtime by allowing the user time to make replacement filters ready. Gas sensors also warn the user if hazardous gas is passing through the system, e.g. due to a missing, damaged or incorrectly fitted filter. Constantly monitors the particle filters to warn the user if hazardous particles are passing through the system, e.g. due to a missing, damaged or incorrectly fitted filter. Flow Control The user can set the required airflow for the process. The motor will automatically speed up or slow down until the “actual” airflow equals the “required” airflow. Purex “Flow Control” automatically increases the speed of the motor as the filter blocks to keep extraction constant and ensure fumes are captured effectively throughout the life of the filter. This system is energy efficient as the motor does not have to constantly run at 100%. It also means the machine is quieter and the filters last longer. Filter Status Filter Indicator Constantly monitors the particle filters to warn the user when they are nearly full. This helps reduce downtime by allowing the user time to make replacement filters ready. FEATURE LIST Speed Control If a filter is nearly blocked or if the gas or particle alarms are triggered, this icon will show which filters may need attention. Temperature Interfacing An adjustable alarm to warn if the filtered air temperature goes above a certain level. Allows the Purex unit to communicate with associated equipment such as lasers or reflow ovens etc. Options: • Synchronised STOP/START • Automatic run on (extraction continues for a set period after associated equipment is stopped.) • Filter Alarm Signals • Several connection types • Remote ON/OFF switch This makes it easier and quicker for the user to identify where the problem may be. This icon also indicates to the user when the motor is running. Graphic Gas Particle Filter Temp Machine Speed Flow Display Sensor Sensor Indicator Warning Interfacing Control Control Filter Life Coated for Warning PVC use Compressor Air 200/400            200i/400i (inc HP)            400i PVC            800i 2-Tier            800i 3-Tier            1500i/2000i            5000i            Alphas (inc Dust)* - - - - -     -  Xbase* - - - - -     -  FumeCube (inc MAX)* - - - - -     - - FumeSafe* - - - - - -    - - 2tiP* - - - - - -  -  - - FumeBuster* - - - - - - - -  - - Captivair* - - - - - - - -  - -  Supplied as standard.  Optional. - Not applicable * Analogue control system only www.purex.co.uk - 41 - purex@purex.co.uk Terms & Conditions 1. Contract 1.1 All quotations given, orders accepted and contracts entered into by Purex International Limited (“Purex”) with any person (“Purchaser”) for supply of goods (“Goods”), or for services (“Services”) are subject to these conditions of sale (“Conditions”). All other terms and conditions, whether expressly stipulated by the Purchaser or implied by trade custom, course of dealing or otherwise are excluded. No variation to these Conditions will be effective unless agreed in writing by an authorised representative of Purex. 6.5 Purex does not exclude or limit its liability in negligence for death or personal injury, or for fraud or wilful default, or otherwise to the extent that any exclusion or limitation of its liability is void, prohibited or unenforceable by law. 1.2 No quotation, estimate or proposal issued by Purex is an offer that is capable of acceptance by the Purchaser. Any order issued by the Purchaser shall be deemed placed subject to these Conditions and shall constitute an offer that Purex may accept or reject.The contract between Purex and the Purchaser (“Contract”) shall be formed at the time Purex accepts the Purchaser’s order. Purex may accept the Purchaser’s order by issuing an order acknowledgement or by other means, including commencing the supply of Goods or the performance of Services. No amendments to the Purchaser’s order shall be valid unless agreed in writing by an authorised representative of Purex. 6.7 Subject to Clause 6.5, in no circumstances shall Purex be liable to the Purchaser, in contract, tort, negligence or otherwise, for any incidental or consequential loss including, without limitation, any loss of profit, business, revenue, goodwill or anticipated savings or for any special, exemplary or consequential damages or other financial loss whatsoever arising out of or in connection with the Contract or the supply of the Goods or Services or their use or resale (if applicable) by the Purchaser. 2. Order and Specifications The Purchaser shall be responsible to Purex for ensuring the accuracy of the terms of any order, including any applicable specification, submitted by the Purchaser, and for giving to Purex any necessary information relating to the Goods or Services within a sufficient time to enable Purex to perform the Contract in accordance with its terms. The specification for the Goods or Services shall be that set out in the Purchaser’s order or as otherwise agreed in writing by Purex. Should an order be cancelled by the Purchaser within 2 months of the relevant delivery date Purex reserves the right to impose a reasonable cancellation charge. 3. Price and Payment 3.1 The price of Goods and Services shall be the price quoted by Purex. Quoted prices shall remain valid for 30 days. Prices do not include carriage and packing which will be charged at cost plus a handling fee unless otherwise specified in writing. Express or Special Delivery at the Purchaser’s request will always be at the Purchaser’s expense. Prices do not include VAT. 3.2 Unless otherwise agreed in writing payment of invoices shall be made in full without any deduction or set-off within 30 days of the invoice date. Payment shall be due whether or not property in the Goods has passed. Time for payment shall be of the essence. If the Purchaser fails to pay Purex any sum due pursuant to the Contract, the Purchaser shall be liable to pay interest to Purex on such sum from the due date for payment at the annual rate of 4% above the base lending rate from time to time of The Bank of England, accruing on a daily basis until payment is made, whether before or after any judgement. Purex reserves the right to claim interest under the Late Payment of Commercial Debts (Interest) Act 1998. Purex may also, without prejudice to any other remedy suspend or cancel further supply of Goods or performance of Services whether under this or any other Contract until the Purchaser makes payment in full together with any applicable interest. 4. Delivery 4.1 Delivery of the Goods shall unless otherwise agreed be made by Purex delivering the Goods to the location specified in the Purchaser’s order or by the Purchaser collecting the Goods at Purex's premises. 4.2 Any dates or times for delivery of Goods and performance of the Services are approximate only. Purex shall use reasonable endeavours to meet such dates or times but so long as it uses such reasonable endeavours Purex shall not be liable to the Purchaser, in contract, tort, negligence or otherwise for any loss or damage whatsoever resulting from any late delivery or performance 4.3 Where the Goods are delivered by instalments, any breach by Purex in respect of any one or more instalments shall not entitle the Purchaser to terminate the Contract in whole or in part. 4.4 Upon receipt of the Goods the Purchaser shall examine them and shall within 48 hours of such receipt give notice in writing to Purex of any apparent defects and/or shortages. The parties will agree between themselves such further action as may be necessary to remedy the defect and/or shortage. Purex shall not be liable for any such defects and/or shortages notified to it after the period of 48 hours after receipt. 5. Risk and Title 5.1 Risk of damage to or loss of the Goods shall pass to the Purchaser when Purex delivers the Goods to the Purchaser or, if the Purchaser collects the Goods from Purex, when the Goods are loaded onto transport at Purex’s premises. 5.2 Notwithstanding the passing of the risk, Purex shall retain title to and ownership of the Goods until it has received payment in full of all sums due for the Goods. 5.3 Until title in the Goods has passed to the Purchaser, the Purchaser shall be in possession of them as a bailee of the Goods for Purex and shall store the Goods, properly insured and protected, separately from any Goods belonging to the Purchaser or any third party and shall be clearly marked and identifiable as being Purex’s property. Purex shall be entitled to enter the Purchaser’s premises upon reasonable notice to verify the Purchaser’s compliance with this clause. If the Purchaser fails to make any payments to Purex when due, or any of the circumstances set out in Clause 8.2 arise, then Purex will have the right, without prejudice to any other remedies: 5.3.1 to enter, without prior notice, any premises where Goods owned by Purex may be, and to repossess and dispose of any such Goods; and/or 5.3.2 to require the Purchaser not to resell or part with possession of any Goods owned by Purex until the Purchaser has paid in full all sums due to Purex under this or any other Contract. 5.4 The Purchaser shall not be entitled to pledge or in any way charge by way of security for any indebtedness any of the Goods which remain the property of Purex and if the Purchaser does so all monies owing by the Purchaser to Purex shall (without prejudice to any other right or remedy of Purex) forthwith become due and payable. 6. Warranty & Liability 6.1 Goods manufactured by Purex : Purex warrants that the Goods manufactured by it will be free from defects in materials and workmanship for a period of 12 months from the date of installation or 15 months from the date of despatch from Purex’s premises, whichever period expires earlier. Exceptions : Spare parts including replacement filters : 3 months from installation or 4 months from despatch Used and ex-demonstration equipment: 3 months from installation or 4 months from despatch In the case of any breach of warranty then Purex shall at its option remedy such defects or refund such sums as the Purchaser has paid to Purex in respect of such Goods. Purex shall be under no liability under the above warranties: 6.1.1 arising from any drawing, design or specification supplied by the Purchaser; 6.1.2 arising from improper installation, storage, use, modification or operation including but not limited to the use of consumable items not approved by Purex; 6.6 Subject to Clauses 6.1 - 6.5, all representations, warranties and conditions implied by trade custom, course of dealing, statute, common law or otherwise are excluded to the fullest extent permitted by law. 6.8 If notwithstanding the provisions of these Conditions Purex is found liable for any loss suffered by the Purchaser arising in any way out of or in connection with the Contract or the supply of any Goods or Services, that liability shall in no event exceed the price paid for such Goods or Services. 6.9 The parties hereby confirm that notwithstanding any other provision of the Contract or these Conditions, the Contract shall not and shall not purport to confer on any third party the right to enforce any term of the Contract for the purposes of the Contracts (Rights of Third Parties) Act 1999. 6.10 Purex and third party Software 6.10.1 Software is licensed (or sublicensed, in case of third party Software) by Purex to the Purchaser. 6.10.2 Purex warrants that the media on which the Software is recorded is free from defects in material and workmanship under normal use for a period of thirty days from the date of despatch. 6.10.3 Purex warrants that any Purex Software will perform in substantial compliance with the specification for a period of 90 days from installation. 6.10.4 Purex warrants that any third party Software will perform in substantial compliance with the Software documentation issued by the original manufacturer of the Software and for the period specified therein. 6.10.5 Purex (and, where applicable, the original manufacturer of the Software) do not warrant that the functions contained in the Software will meet Purchaser’s requirements or operate in the combination that may be selected for use by Purchaser, that the operation of the Software will be uninterrupted or error-free or that all defects in the Software will be corrected. 6.10.6 The entire liability of Purex (and, where applicable, of the original manufacturer of the Software) shall be, at Purex’s option, either : (a) Return of all sums paid by the Purchaser for the Software, or (b) Replacement of the Software or media that does not meet Purex or the original manufacturer limited warranty and which is returned to Purex under its return policy. 6.10.7 Any replacement Software or media will be warranted for the remainder of the original warranty period or 30 days, whichever is longer. 7. Force Majeure Purex shall not be deemed in breach of the Contract or otherwise liable to the Purchaser, by reason of any delay in performance, or non-performance of its obligations under the Contract to the extent that such delay or nonperformance is caused by an event or circumstance beyond Purex’s reasonable control. In such events Purex may, without liability to the Customer, reasonably vary the terms of the Contract including but not limited to extending the time for performing the contract by a period of at least equal to the time lost due to such an event. 8. Termination 8.1 Purex may at any time by notice in writing to the Purchaser terminate the Contract with effect from the date of service of such notice if: 8.1.1 The Purchaser commits a material breach of the Contract and fails to remedy such breach within 14 days after Purex has given written notice to the Purchaser identifying the breach and requiring it to be remedied; or 8.1.2 The Purchaser is unable to pay its debts as they fall due within the meaning of Section 123 of the Insolvency Act 1986 or if any petition is presented for the appointment of an administrator or receiver or trustee in bankruptcy in respect of the Purchaser or any part of its undertaking or assets or an administrative receiver is appointed in respect of any of the Purchaser’s undertaking or assets or if the Purchaser makes or attempts to make any arrangement with or for the benefit of its creditors or if the Purchaser ceases or threatens to cease to carry on business. 9. Miscellaneous 9.1 The expressions “in writing” and “written” include fax transmission. Purex shall be entitled to sub-contract any or all of its obligations under the Contract and to assign the Contract and the Customer shall at Purex’s cost do all such things as may be necessary to enable Purex to so assign the Contract. Any failure or neglect by Purex to enforce at any time any provision of the Contract shall not be construed nor deemed to be a waiver of any of Purex’s rights under the Contract. The Contract shall be governed by and construed in accordance with English law and the parties hereby submit to the exclusive jurisdiction of the English courts in relation to any claim or controversy arising out of or connected with the Contract. 9.2 New Accounts : Credit accounts cannot be opened under the minimum amount in operation at the time of placing the order. Customer’s wishing to open a credit account must furnish two trade references and a Bank reference. 9.3 Specification Alterations : Purex reserves the right to alter the specification of any goods without prior reference to the Purchaser provided that the goods comply in all other known respects with the Purchaser’s requirements. 9.4 Trade-Marks / Patents : The supply of goods by Purex shall not confer any right upon the Purchaser to use any Purex trade-mark without prior written consent of Purex and at all times such trade-mark shall remain the property of Purex. Neither does it imply any right to use any Purex patent or any indemnity against infringement of third party patents. 9.5 Catalogues : Catalogues and other advertising matter are issued to indicate the type and range of goods we offer and no particulars therein are binding to Purex. 6.2 Goods manufactured by third parties : Purex will use its best endeavours to obtain for the purchaser the benefit of any warranty provided by the original manufacturer of the Goods. Repair or replacement, in whole or in part, of Goods which fail due to faulty manufacture is available from the original manufacturer under its warranty. Purex must be consulted to approve the return of Goods for replacement or repair under the original manufacturer’s warranty. 6.3 All replacement items will be charged at the point of despatch. Provided the original items are received back at Purex within 28 days from the date upon which the Returns Authorisation Number is issued and Purex agree following testing / inspection that these are defective, a credit note will be issued. 6.4 Services : Purex warrants that it will carry out the Services with reasonable care and skill. If Purex is shown to be in breach of this warranty in respect of particular Services it shall at its option and cost either re-provide those Services or refund any sums already paid in respect of those Services. www.purex.co.uk - 42 - purex@purex.co.uk 111072 202271* F8/F9 FumeCube 111117 202275* 202271* 202274* 111124 111006 111099 202273* 111107 Cascade 110545 113505H 113505 110507 110531 110531 110507 110536 110615 113652 113498 113811† 113505H 113505 113505H 113505 Chemical HEPA 113668≈ 113579Δ 110614Δ 113660Δ 113668≈ 113579Δ 113579Δ Chemical Twin HEPA 113669≈ 113512 110533 110533 110538 110632 113658 113669≈ 113512 113512 Cleanroom Chemical HEPA 113800 113805 113508 110532 110532 110504 110537 110624† 110627 110610 113651 113508 113508 Std Chemical MAIN FILTERS 113809 110633 113650 113809 113809 HEPA 113662 110542 110542 ≈110544 113662 113505P≈ 113662 Special Chemical 113531 110645 113531 113531 Bag Pleated 113585 CSA HEPA www.purex.co.uk - 43 - 110541 110541 110543 113667 113513 Lock Solvent purex@purex.co.uk * Pack of 2 • # Pack of 4 • All other filters sold in singles • † Heavy Duty • Δ Rubber Engraving • ≈ Acidic Fumes • Note: The FumeSafe has an exhaust filter 200093 Cascade Box Captivair (Refill) Xbase 202268* 200098# Alpha Dust 200225# 2 Tip 202269* See note. FumeSafe 111037 Alpha 200314# FumeBuster 200226# 200225# 5000i 200098# 200312# 200310# 1500i/2000i FumeCube Max 200262# 200281# 800i 3-Tier 202272* 200262# 202280* F8 Labyrinth 800i 2-Tier 202268* F6 Labyrinth 202271* 111144 Bag Labyrinth 200261# PVC Adsorbent Pleated PRE-FILTERS Pad 400i PVC 200316# F8/F9 Pad 202271* 200226# F6 F5 202260# Pad Pad 200i-HP 200i/400i 200/400 MACHINE Filter Matrix “Protecting People and the Environment with Innovative Technology” T: +44 (0)1709 763000 F: +44 (0)1709 763001 E: purex@purex.co.uk W: www.purex.co.uk Registered Office. Purex International Ltd. Purex House, Farfield Park, Manvers, Rotherham, S63 5DB. Registered No. 5136616 England. VAT No. GB842 5025 49 • WEEE Producer Registration Number: WEE/CE0067TX 2011/65/EU
110507
1. 物料型号:文档中列出了多种型号的烟尘净化设备,例如 FumeCube Max、FumeSafe、2tiP、FumeBuster、Captivair Max 等,以及它们的不同配置和选项。

2. 器件简介:PUREX 提供了一系列烟尘净化解决方案,旨在保护个人和环境免受有害烟雾和粉尘的影响。这些系统可以从小规模的单人使用到大规模的中央系统,满足多用户或高容量自动化流程的需求。

3. 引脚分配:虽然文档中没有明确提到“引脚分配”,但提到了各种型号的接口套件和连接选项,这些可以被视为设备的“引脚分配”。

4. 参数特性:文档详细列出了不同型号的电压、功率、频率、尺寸、重量等参数,以及它们的控制和监测系统特性。

5. 功能详解:PUREX 的烟尘净化系统具备多种功能,包括自动电子流量控制、可调节的气流、清晰的图形显示、气体和颗粒物传感器、以及与外部设备的接口能力。

6. 应用信息:这些系统适用于多种应用场景,如激光打标、连续喷墨编码、激光雕刻、宽幅打印、回流和波峰焊接、手工焊接、激光和机器人焊接、底漆和保护涂层、无尘室和实验室、教育和工程等。

7. 封装信息:文档提供了不同型号的烟尘净化设备的尺寸、重量和构造信息,如不锈钢构造、高性能无刷电机、以及安装在脚轮上以提高机动性。

此外,文档还提供了关于健康和安全法规的信息,强调了雇主有责任保护员工的健康、福利和安全,并遵守当地和国际的健康安全法规,如 COSHH、NIOSHH、OSHA 等。还讨论了不同类型的烟尘净化系统,包括外部排放系统和内部捕获过滤或 LEV(局部排气通风)系统,并比较了它们的优缺点。
110507 价格&库存

很抱歉,暂时无法提供与“110507”相匹配的价格&库存,您可以联系我们找货

免费人工找货