200W Single Output
Industrial Grade
CINT1200 Family
FEATURES AND BENEFITS
Industrial
3” x 5” x 1.3” Package
Approved to EN/CSA/IEC/UL62368-1
200W with 100LFM Air
Efficiency 90% Typical
180W Convection Cooled
3 Years Warranty
Fits 1U Applications
Universal Input 90-264 VAC
Class B Conducted EMI
RoHS Compliant
MODEL SELECTION
Model Number
Volts
Output Current
w/100LFM air Convection*
Minimum
Load
Ripple &
Noise**
Total
Regulation
OVP
Threshold***
CINT1200A1275K01
12V
16.7A
15.0A
0A
120mV pk-pk
±3%
14.0 ± 1.1V
CINT1200A1575K01
15V
13.3A
12.0A
0A
150mV pk-pk
±3%
18.5 ± 1.2V
CINT1200A1875K01
18V
11.1A
10.0A
0A
180mV pk-pk
±3%
21.5 ± 2.0V
CINT1200A2475K01
24V
8.33A
7.50A
0A
240mV pk-pk
±3%
29.0 ± 2.5V
CINT1200A2875K01
28V
7.14A
6.40A
0A
280mV pk-pk
±3%
33.5 ± 2.5V
CINT1200A3275K01
32V
6.25A
5.62A
0A
320mV pk-pk
±3%
36.0 ± 3.0V
CINT1200A3675K01
36V
5.55A
5.00A
0A
360mV pk-pk
±3%
41.0 ± 3.0V
CINT1200A4875K01
48V
4.17A
3.75A
0A
480mV pk-pk
±3%
56.0 ± 3.0V
Notes : * Total convection power is 180 Watts.
** Measured with noise probe directly across output terminals, and load terminated with 0.1μF ceramic and 10μF low ESR capacitors.
INPUT
OUTPUT
AC Input
100-240VAC, ±10%, 47-63Hz, 1Ø
120-370V DC
Input Current
115VAC: 1.8A, 230VAC: 0.9A
Inrush Current
264VAC, Cold start: will not exceed 55A
Input Fuses
F1, F2: 3.15A, 250VAC fuses provided on all models
Earth Leakage
Current
很抱歉,暂时无法提供与“CINT1200A1575K01”相匹配的价格&库存,您可以联系我们找货