275W Single Output
Industrial Grade
CINT1275 Family
FEATURES AND BENEFITS
Industrial
3” x 5” x 1.40” Package
Inhibit, Power Fail, Output OK Signals
Up to 275W of AC-DC Power
Approved to EN/CSA/IEC/UL62368-1
For 1U Applications
Efficiency 92% Typical
Universal Input 90-264VAC Input Range
3 Years Warranty
Standby and Fan Output Voltages
RoHS Compliant
Forced Current Share
MODEL SELECTION
Output Current
Fan Output
Ripple &
Noise**
Total
Regulation
15.0A
12V DC/1A
120mV pk-pk
±3%
14.0 ± 1.1V
18.3A
12.0A
12V DC/1A
150mV pk-pk
±3%
19.5 ± 1.5V
24V
10.9A
7.50A
12V DC/1A
240mV pk-pk
±3%
28.0 ± 2.5V
CINT1275A4814K01
48V
5.46A
3.75A
12V DC/1A
480mV pk-pk
±3%
55.0 ± 4.0V
CINT1275A5614K01
56V
4.68A
3.21A
12V DC/1A
560mV pk-pk
±3%
59.0 ± 1.0V
Model Number
Volts
CINT1275A1214K01
12V
21.8A
CINT1275A1514K01
15V
CINT1275A2414K01
w/200LFM air
Convection*
OVP
Threshold***
Note: * Total convection power is 180 Watts.
** Measured with noise probe directly across output terminals, and load terminated with 0.1μF ceramic and 10μF low ESR capacitors.
*** No output adjustment on 56V.
INPUT
OUTPUT
AC Input
100-240VAC, ±10%, 47-63Hz, 1Ø
120-370V DC
Hold-Up Time
16ms at 250W, 120VAC/60Hz
Input Current
115VAC: 3A, 230VAC: 1.5A
3.7A max at 90VAC
Turn On Time
Less than 2 sec @115VAC (inversely proportional to
input voltage and thermistor temperature)
Inrush Current
264VAC, cold start: will not exceed 50A
Input Fuses
F1, F2: 5A, 275VAC fuses provided on all models
Switching
Frequency
PFC: Variable, 30kHz - 400kHz
Main converter: Variable 30-250kHz, 65-70kHz at
full load
Earth Leakage
Current
很抱歉,暂时无法提供与“CINT1275A4814K01”相匹配的价格&库存,您可以联系我们找货