Additional Resources:
Product Page
|
3D Model
date
06/02/2022
page
1 of 5
SERIES: VF-S320-XXA-CFS │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
•
up to 320 W continuous power
700 W peak power within 500 µs duty duration
metal top cover and side fan
passive power factor correction
power good signal
3,000 Vac isolation voltage
over load, over voltage, over temperature, and short circuit protections
UL/EN/IEC 62368 certified
efficiency up to 83%
RoHS
MODEL
VF-S320-05A-CFS*
VF-S320-09A-CFS*
output
voltage
output
current
output1
power
ripple and
noise 2,3
efficiency
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
5
45
225
50
75%
9
29.1
262
90
83%
VF-S320-12A-CFS
12
26.67
320
120
80%
VF-S320-15A-CFS
15
21.33
320
150
83%
VF-S320-18A-CFS
18
17.78
320
180
83%
VF-S320-24A-CFS
24
13.33
320
240
83%
VF-S320-28A-CFS
28
11.43
320
280
83%
VF-S320-36A-CFS
36
8.89
320
360
83%
VF-S320-48A-CFS
48
6.67
320
480
83%
VF-S320-54A-CFS
54
5.93
320
540
83%
Notes:
1. 1% minimum load is required to maintain the ripple and regulation.
2. Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with a 0.1 μF ceramic capacitor and a 22 μF electrolytic capacitor in parallel.
3. * Discontinued model.
PART NUMBER KEY
VF - S320 - XX A - CFS - X
Base Number
Output Voltage
Input/Output connector:
“blank” = Terminal block input / Terminal block output
1 = Molex input / Molex output
2 = Molex input / Terminal block output
3 = Terminal block input / Molex output
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VF-S320-XXA-CFS │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/02/2022 │ page 2 of 5
INPUT
parameter
conditions/description
voltage
90-132/180-264 auto selectable
min
frequency
current
at 100~120 Vac, cold start
at 200~240 Vac, cold start
inrush current
at 115 Vac, full load, cold start
at 230 Vac, full load, cold start
power factor
compliant to EN 61000-3-2 class A
max
units
90/180
typ
132/264
Vac
47
63
Hz
8
4
A
A
35
70
A
A
max
units
OUTPUT
parameter
conditions/description
line regulation
low line to high line
load regulation
all other outputs
min
typ
±1
temperature coefficient
±1
%
0.25
mV/°C
transient response
Output voltage returns to within 1% in less than 2.5 ms for a 50% load change.
Peak transient does not exceed 5%.
start-up time
at 120 Vac
rise time
hold-up time
0.2
at 120 Vac and 80% of rated maximim load
%
1
s
20
ms
20
ms
adjustability
±5
power good
Designated as PG on the CN1.
This signal goes high 100-500 mS after the output reaches regulation.
It goes low at least 1 mS before loss of regulation.
fan drive
12 Vdc / 300 mA for external fan
%
PROTECTIONS
parameter
conditions/description
min
typ
over voltage protection
AC input needs to be reset to restart the power supply.
over current protection
automatically recovers
short circuit protection
short circuit can be continuous, recovers automatically upon removal of short
over temperature protection
auto recovery
110
max
units
130
%
140
%
85
°C
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
applied for 3 seconds at 10 mA max.
primary to secondary
primary to transformer core
primary to earth chassis
min
safety approvals
certified to 62368: IEC, EN, UL
EMI/EMC
pass FCC Part 15, CISPR 22 class B, conducted
leakage current
at 240 Vac
at 120 Vac
RoHS compliant
yes
MTBF
according to MIL-HDBK-217 at 30 ºC
typ
3,000
1,500
1,500
Vac
Vac
Vac
500
300
cui.com
100,000
μA
μA
hrs
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VF-S320-XXA-CFS │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/02/2022 │ page 3 of 5
ENVIRONMENTAL
parameter
conditions/description
operating temperature
see derating curve
min
typ
0
storage temperature
max
units
70
°C
-20
85
°C
operating humidity
non-condensing
5%
90%
%
storage humidity
non-condensing
5%
95%
%
vibration
acceleration ± 7.35 M/(SxS), on X, Y and Z Axis
5
50
Hz
max
units
DERATING CURVES
MECHANICAL
parameter
conditions/description
dimensions
177.80 x 101.60 x 39.30 [7 x 4 x 1.6 inch]
min
weight
typ
mm
750
cui.com
g
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VF-S320-XXA-CFS │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/02/2022 │ page 4 of 5
MECHANICAL DRAWING
units: mm[inches]
tolerance: ±0.3 mm
unless otherwise specified
25.40 1.000
(2 PLCS)
25.40 1.000
101.60 4.000
SCALE: 1:3
CN1
1
ground
2
ac neutral
3
ac line
12.70 0.500
(TYP)
25.40 1.000
101.60 4.000
connector part no.
JS-1120-05
(5 pins, 3 used)
L
101.60 4.000
CN2
1
Vo+
2
Vo+
3
Vo+
4
Vo+
5
Vo+
6
Vo-
7
Vo-
8
Vo-
9
Vo-
10
Vo-
76.20 3.000
(2 PLCS)
A
UNC 8-32
(6 PLCS)
+
CN3
power good
2
RTN
3
fan fail
-
177.80 7.000
CN3
FF
RTN
PG
39.30 1.547
DETAIL A
SCALE 2 : 1
Notes:
1.
2.
3.
4.
5.
N
G
G
VO-
VO-
VO+
VO+
terminal block option
M3.5 screw
7pins 9.5mm center
FAN2
1
L
N
CN1 mates with JST VH series 5-pin connector.
CN2 mates with VH series 10-pin connector.
CN3 mates with JST XHP-3 or equivalent (CHYAO SHIUNN JS-2001-03) and JST SXH-002T-P0.6 mating pins
Fan drive connector mates with JST part no. XHP-2 or equivalent
Mounting hole max depth 4.00mm
cui.com
connector part no.
JS-1120-10
(10 pins)
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VF-S320-XXA-CFS │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/02/2022 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
05/5/2009
1.01
new template applied
12/17/2011
1.02
V-Infinity branding removed
08/28/2012
1.03
removed on/off information, removed low leakage option, updated spec
04/23/2013
1.04
company logo updated
12/22/2020
1.05
safeties updated
02/10/2021
1.06
derating curve updated
04/21/2021
discontinued models VF-S320-05A-CFS & VF-S320-09A-CFS
06/02/2022
1.07
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
很抱歉,暂时无法提供与“VF-S320-54A-CFS-1”相匹配的价格&库存,您可以联系我们找货