VMS-300A-48-CNF

VMS-300A-48-CNF

  • 厂商:

    CUIDEVICES

  • 封装:

    -

  • 描述:

    AC-DC,300W,48VDC,SINGLEOUT

  • 数据手册
  • 价格&库存
VMS-300A-48-CNF 数据手册
Additional Resources: Product Page | 3D Model date 10/27/2022 page 1 of 10 SERIES: VMS-300A │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • • • • • • • up to 300W continuous power universal input voltage range industry standard 3” x 5” footprint power factor correction remote voltage sense & on/off control fan & 5 Vdc aux outputs covered and open-frame configurations over voltage, over current, over temperature, and short circuit protections medical 60601-1 (4th edition) safety approvals designed for 2 x MOPP applications efficiency up to 94% TUVRheinland EN 60601-1 IEC 60601-1 www.tuv.com ID xxxxxxxxxx MODEL output voltage output current output power1 ripple and noise2 efficiency3 (Vdc) max (A) max (W) max (mVp-p) typ (%) VMS-300A-12 12 25 300 120 92.5 VMS-300A-24 24 12.5 300 150 93.5 VMS-300A-36 36 8.34 300 150 93.5 VMS-300A-48 48 6.25 300 150 94 5 1 5 100 -- Vstb4 Notes: 1. 2. 3. 4. 5. Maximum output power of 300 W (5 W for Vstb) with 10 CFM forced air, 200 W (3 W for Vstb) with convection cooling. At full load, nominal input, 20 MHz bandwidth oscilloscope, output terminated with 10 μF electrolytic and 0.1 μF ceramic capacitors. At full load, 25°C, 230 Vac input. Standby output voltage. Present on all models. All specifications are measured at Ta=25°C, 230 Vac input voltage, and 60% rated output load unless otherwise specified. PART NUMBER KEY VMS-300A - XX - XXX - X Base Number Output Voltage Chassis: “blank” = open-frame CNF = covered cui.com Input Connector: “blank” = TAIWAN KING PIN TERMINAL PVHI series 1 = LONG CHU P3060 series Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VMS-300A │ DESCRIPTION: AC-DC POWER SUPPLY date 10/27/2022 │ page 2 of 10 INPUT parameter conditions/description min voltage typ 90 frequency 47 max units 264 Vac 63 Hz current at 100 Vac at 240 Vac 4.0 1.8 A A inrush current at 240 Vac, 25°C, cold start 30 A leakage current 0.3 mA leakage current (enclosure/ patient) 0.1 mA 0.3 W max units 25,000 12,500 5,000 3,750 μF μF μF μF power factor correction meets EN 61000-3-2 no load power consumption measured with the PS-ON signal configured to OFF OUTPUT parameter conditions/description output capacitance at 115/230 Vac, full load 12 Vdc output models 24 Vdc output models 36 Vdc output models 48 Vdc output models initial set point accuracy at full load, 25°C Vo Vstb line regulation high line to low line at full load Vo Vstb load regulation from full to 10% load Vo Vstb hold-up time adjustability switching frequency at full load min ±1 ±3 % % ±0.5 ±1 % % ±1 ±5 % % at 115 Vac 16 ms built in trim pot (VR) ±5 % 60 temperature coefficient 80 ±0.05 power on PS-ON signal1 power off PS-ON 0 PS-ON = 0V kHz %/°C 2 4.5 Vdc mA PS-ON = NC (internal circuit will drive PS-On to 11~16 Vdc) PS-ON = NC 0 power good (PG) TTL goes high 50~250 ms after powered on TTL goes low 5~20 ms before 90% Vo standby output voltage 5 Vdc / 1 A fan output 12 Vdc / 500 mA Notes: typ mA 1. When not used, short PS-ON & signal GND. PROTECTIONS parameter conditions/description over voltage protection latch mode 12 Vdc output 24 Vdc output 36 Vdc output 48 Vdc output min models models models models typ max 15 30 43 56 over current protection 130 short circuit protection hiccup, auto recovery over temperature protection auto recovery (temperature of C37) cui.com 150 units Vdc Vdc Vdc Vdc 180 % 110 °C Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VMS-300A │ DESCRIPTION: AC-DC POWER SUPPLY date 10/27/2022 │ page 3 of 10 SAFETY & COMPLIANCE parameter conditions/description isolation voltage input to output (2MOPP) for 1 minute input to earth (1MOPP) for 1 minute output to earth (1MOPP) for 1 minute min isolation resistance typ max units 4,000 1,500 1,500 Vac Vac Vac 100 MΩ safety approvals UL/cUL 60601-1, IEC 60601-1, EN 60601-1 (4th edition) safety class class I EMI/EMC EN55011, EN55022 Class B, EN55024, FCC Class B, EN61204-3, EN61000-6-1, EN61000-6-3, EN60601-1-2, EN61000-3-2, EN61000-3-3 MTBF as per MIL-HDBK-217F, at 115 Vac, 25°C, GB RoHS Notes: 100,000 hours 2011/65/EU 1. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives. ENVIRONMENTAL parameter conditions/description min max units operating temperature see derating curves -40 80 °C -40 85 °C 93 % storage temperature operating humidity typ non-condensing operating altitude 3000 m vibration2 as per MIL-STD-810F Table 514.5C-VIII; 15~2000 Hz for 1 hour on each axis for 3 hours 4 G shock2 as per MIL-STD-810F Table 516.5, Table 516.5-1; for 10 ms on each axis 3 times 75 G Notes: 2. See Installation Instructions for mounting requirements. DERATING CURVES cui.com Additional Resources: Product Page CUI Inc │ SERIES: VMS-300A │ DESCRIPTION: AC-DC POWER SUPPLY | 3D Model date 10/27/2022 │ page 4 of 10 DERATING CURVES (CONTINUED) EFFICIENCY CURVES cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VMS-300A │ DESCRIPTION: AC-DC POWER SUPPLY date 10/27/2022 │ page 5 of 10 MECHANICAL parameter conditions/description dimensions VMS-300A models: 5.00 x 3.00 x 1.38 (127 x 76.2 x 35.1 mm) VMS-300A-CNF models: 5.35 x 3.46 x 1.59 (136 x 88 x 40.4 mm) min weight VMS-300A models VMS-300A-CNF models cooling external fan CN1 input connector CN1 mates with JST housing VHR series or equivalent CN1 input connector (optional) CN1 mates with MOLEX housing 5195 series or equivalent CN4 output connector CN4 mates with JST housing PH series or equivalent CN5 output connector CN5 mates with JST housing PH series or equivalent output terminals +Vo & -Vo terminals are M3 screws that mate with round or Y terminals with max OD of 6.75 mm and max ID of 3.9 mm Open-frame units: inch [mm] tolerance: X.XXX = ±0.020 [±0.50] CN1 Function 1 ACL 2 - 3 ACN CN4 PIN Function 1 -FAN 2 +FAN 3 GND 4 +5 VSB 5 GND 6 PS-ON CN5 PIN Function 1 GND 2 PG 3 -Sense 4 +Sense cui.com max units inch inch 410 515 MECHANICAL DRAWING PIN typ g g Additional Resources: Product Page CUI Inc │ SERIES: VMS-300A │ DESCRIPTION: AC-DC POWER SUPPLY Covered units: inch [mm] tolerance: X.XXX = ±0.020 [±0.50] CN1 Function 1 ACL 2 - 3 ACN CN4 PIN Function 1 -FAN 2 +FAN 3 GND 4 +5 VSB 5 GND 6 PS-ON CN5 PIN Function 1 GND 2 PG 3 -Sense 4 +Sense 3D Model date 10/27/2022 │ page 6 of 10 MECHANICAL DRAWING (CONTINUED) PIN | cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VMS-300A │ DESCRIPTION: AC-DC POWER SUPPLY date 10/27/2022 │ page 7 of 10 INSTALLATION INSRUCTIONS The VMS-300A series has (4) 4 mm diameter mounting holes that can be used in (3) types of installations. Type 1 Mounting from top with spacers (required to meet vibration specifications) Spacer: 4 mm diameter max, 8 mm high minimum Screw Size: (4) M3X0.5 Mounting torque: 3 kgf-cm Type 3 Mounting from bottom Type 2 Mounting from top without spacers Screw Size: (4) M3X0.5 Mounting torque: 3 kgf-cm Mounting Torque Screw Size: (4) M4X0.7 Mounting torque: 7 kgf-cm VMS-300A VMS-300A-CNF cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VMS-300A │ DESCRIPTION: AC-DC POWER SUPPLY date 10/27/2022 │ page 8 of 10 INSTALLATION INSRUCTIONS (CONTINUED) Output Terminals Mate with round or Y terminals with max OD of 6.75 mm and max ID of 3.9 mm Terminal Size: (2) M3 Torque: 3 kgf-cm Mounting Clearance Allow at least 4 mm side clearance and 5 mm height clearance. If clearances aren’t met, the isolation and withstand specifications may not be met. Field Ground Should be connected to the earth (ground) terminal of the apparatus otherwise conducted noise and output noise will increase. cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VMS-300A │ DESCRIPTION: AC-DC POWER SUPPLY date 10/27/2022 │ page 9 of 10 APPLICATION NOTES On/off Remote Control A PS On/Off remote control is provided in CN4. See Figure 1 for the PS-ON diagram and control function. Figure 1 VMS-300A Note: Power on: VPS-ON ≤ 2V, IPS-ON ≥ 2 mA (PS-ON and GND short, IPS-ON = 4.5 mA typical) Power off: Open circuit, VPS-ON = 11~16 V When the PS On/off remote control function is not used, connect a short circuit between the PS-ON control & the signal GND. Output Remote Sensing The VMS-300A series can remotely sense both lines of the output. The feature moves the effective voltage regulation point from the output of the unit to the point of connection of the remote sense pins. This feature automatically adjusts the real output in order to compensate for voltage drops in distribution and maintain a regulated voltage at the point of load. The remote sense voltage range is as follows: [(+Vout) – (-Vout)] – [(+Sense) – (-Sense)] ≤ 10% Vo_nominal If the remote sense is not used, the sense pins should be connected locally to the respective Vout pins. The remote sense pins are located on CN5. Figure 2 VMS-300A cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VMS-300A │ DESCRIPTION: AC-DC POWER SUPPLY date 10/27/2022 │ page 10 of 10 REVISION HISTORY rev. description date 1.0 initial release 12/06/2016 1.01 updated safety approvals to 4th edition 05/16/2017 1.02 updated datasheet 01/31/2018 1.03 company logo updated 12/17/2020 1.04 output remote sensing updated 02/09/2021 1.05 curves and figures updated 05/04/2021 1.06 mechanical drawing updated 06/09/2021 1.07 derating curves updated 06/23/2022 1.08 mechanical drawing for covered model updated 10/11/2022 1.10 UKCA mark added 10/27/2022 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
VMS-300A-48-CNF 价格&库存

很抱歉,暂时无法提供与“VMS-300A-48-CNF”相匹配的价格&库存,您可以联系我们找货

免费人工找货