XT40.241

XT40.241

  • 厂商:

    PULS

  • 封装:

    -

  • 描述:

    AC/DCCONVERTER24V960W

  • 数据手册
  • 价格&库存
XT40.241 数据手册
XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series SEMI-REGULATED POWER SUPPLY • • • • • • • • • • • • • GENERAL DESCRIPTION Alternative or Replacement for AC Transformer Three Phase Input – DC Output DIN-Rail Mountable Width only 96mm 95.5% Efficiency 125% Peak Power Capability No Input Inrush Current Active Input Transient Blocker Full Power Between -25°C and +60°C Easy Failure Diagnostics No Electrolytic Capacitors on Input Side Cost Effective and Robust 3 Year Warranty SHORT-FORM DATA Output voltage The power supplies in the Dimension X-Series include a new and innovative concept for generating an isolated DC voltage from a three-phase mains system. A semi-regulated resonant converter enables a very compact design, maximum efficiency and extremely competitive pricing with only a small compromise in the output voltage regulation, output ripple and hold-up time. Weighing just 1.4 kg, the device provides 960 watts of continuous output power and an additional 25% power reserve for dynamic loads. The light-weight design along with compact dimensions facilitate straightforward mounting on DIN-rail. Primary use are applications involving supplies to motors, valves and other load circuits with a high power consumption, where an accurate output voltage regulation which is standard on traditional switched-mode power supplies is not required. Furthermore, these switched-mode power supplies can often replace mains transformers with rectifiers. ORDER NUMBERS Power Supply Accessory DC 24V Adjustment range Output current none 40A 50A Output power 960W 1200W Output ripple < 1500mVpp < 200mVpp Input voltage 3AC 400V 3AC 480V Mains frequency 50-60Hz AC Input current 1.65A / phase 1.4A / phase Power factor 0.93 AC Inrush current typ. 2A peak Efficiency 95.5% Losses 45.2W Temperature range -25°C to +70°C Derating 24W/°C Dimensions 96x124x159mm Factory setting to 24.1V continuous for typ. 15s continuous for typ. 15s 20Hz-2kHz 2kHz to 20MHz XT40.241 XT40.242 ±6% XT40.241, 3x400V XT40.242, 3x480V 24V, 40A operational +60 to +70°C WxHxD MARKINGS XT40.241 400V Input XT40.242 480V Input UF20.241 24V Buffer Unit SLR01 Redundancy Module UL 508 UL 60950-1 Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany IEC 60950-1 1/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series INDEX 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. PAGE Intended Use .......................................................3 Installation Instruction ........................................3 AC-Input...............................................................4 Input Inrush Current ...........................................5 Output .................................................................6 Hold-up Time .......................................................7 Efficiency and Power Losses................................8 Functional Diagram.............................................9 Front Side and User Elements .............................9 Terminals and Wiring ........................................10 Reliability ...........................................................10 EMC ....................................................................11 Environment ......................................................12 Protection Features ...........................................13 Safety .................................................................13 Dielectric Strength ............................................13 Approvals and Fulfilled Standard .....................14 Regulatory Compliance .....................................14 Physical Dimensions and Weight ......................15 INDEX PAGE 20. Installation and Operation Instructions .......... 15 21. Accessories ........................................................ 16 22. Comparison between the XT40, a Transformer and a Traditional Switched-mode Power Supply .. 16 23. Application Notes ............................................. 17 23.1. Periodical Peak Power Capability .......... 17 23.2. Charging of Batteries ............................. 17 23.3. Output Circuit Breakers ......................... 18 23.4. External Input Protection....................... 19 23.5. Back-feeding Loads ................................ 19 23.6. Parallel Use to Increase Output Power . 19 23.7. Parallel Use for Redundancy .................. 19 23.8. Series Operation ..................................... 20 23.9. Inductive and Capacitive Loads ............. 20 23.10. Loss of One Input Phase ......................... 20 23.11. Use in a Tightly Sealed Enclosure .......... 20 23.12. Mounting Orientations .......................... 21 TERMINOLOGY AND ABREVIATIONS PE and symbol PE is the abbreviation for Protective Earth and has the same meaning as the symbol . Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”. T.b.d. To be defined, value or description will follow later. 3AC 400V A figure displayed with the AC or DC before the value represents a nominal voltage with standard tolerances (usually ±15%) included. 3AC means three phase input. E.g.: DC 12V describes a 12V battery disregarding whether it is charged (13.7V) or discharged (10V) As long as otherwise stated, 3AC 400V parameters are valid at 50Hz and 3AC 480V parameters are valid at 60Hz mains frequency. 3x 400Vac A figure with the unit (Vac) at the end is a value which is used during testing without any additional tolerances included. 3x 400Vac means a three phase input. DISCLAIMER The information presented in this document is believed to be accurate and reliable and may change without notice. Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 2/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 1. INTENDED USE This device is designed for installation in an enclosure and is intended for commercial use such as in industrial control, process control, monitoring and measurement equipment or the like. The principal use are applications such as motors, valves and other load circuits with high power consumption, where an accurate output voltage regulation and low amount of ripple voltage (standard on switch mode power supplies) is not required. Do not use this device in equipment, where malfunctioning may cause severe personal injury or threaten human life without additional appropriate safety devices, that are suited for the end application. If this device is used in a manner outside of its specification, the protection provided by the device may be impaired. 2. INSTALLATION INSTRUCTION Install device in an enclosure providing protection against electrical, mechanical and fire hazards. Install the device onto a DIN-rail according to EN 60715 with the input terminals on the bottom of the device. Other mounting orientations require a reduction in output current. Make sure that the wiring is correct by following all local and national codes. Use appropriate copper cables that are designed for a minimum operating temperature of 60°C for ambient temperatures up to +45°C, 75°C for ambient temperatures up to +60°C and 90°C for ambient temperatures up to +70°C. Ensure that all strands of a stranded wire enter the terminal connection. Use ferrules for wires on the input terminals. Unused screw terminals should be securely tightened. The device is designed for pollution degree 2 areas in controlled environments. No condensation or frost is allowed. The housing of the device provides a degree of protection of IP20. The housing does not provide protection against spilled liquids. The isolation of the device is designed to withstand impulse voltages of overvoltage category III according to IEC 60664-1. The device is designed as “Class of Protection I” equipment according to IEC 61140. Do not use without a proper PE (Protective Earth) connection. The device is suitable to be supplied from TN, TT or IT mains networks. The continuous voltage between the input terminal and the PE potential must not exceed 400Vac. The device is not designed to be used on corner grounded delta systems. A disconnecting means shall be provided for the input of the device. The device is designed for convection cooling and does not require an external fan. Do not obstruct airflow and do not cover ventilation grid! The device is designed for altitudes up to 5000m (16400ft). Above 2000m (6560ft) a reduction in output current and over voltage category is required. Keep the following minimum installation clearances: 40mm on top, 20mm on the bottom, 5mm left and right side. Increase the 5mm to 15mm in case the adjacent device is a heat source. When the device is permanently loaded with less than 50%, the 5mm can be reduced to zero. The device is designed, tested and approved for branch circuits up to 16A (IEC) and 15A (UL) without additional protection device. If an external fuse is utilized, do not use circuit breakers smaller than 6A B- or 3A C-Characteristic to avoid a nuisance tripping of the circuit breaker. The maximum surrounding air temperature is +70°C (+158°F). The operational temperature is the same as the ambient or surrounding air temperature and is defined 2cm below the device. The device is designed to operate in areas between 5% and 95% relative humidity. Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 3/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 3. AC-INPUT AC input Mains arrangement AC input range Input frequency Turn-on voltage Shut-down voltage Input current Power factor **) Turn-on overshoot Start-up delay ***) Rise time *) **) ***) nom. XT40.241 XT40.242 3AC 400V 3AC 480V TN-, TT- or IT-Mains 3x 360-440Vac 3x 432-528Vac *) 3x 300-460Vac 3x 360-552Vac *) max. 3x 475Vac 3x 565Vac nom. typ. typ. nom. typ. typ. typ. typ. typ. 50 – 60Hz 3x 325Vac 3x 295Vac 1.65A 0.93 480mV 400ms 40ms 70ms 50 – 60Hz 3x 390Vac 3x 355Vac 1.4A 0.93 480mV 350ms 40ms 70ms consult factory if one phase is earthed fully regulated output (±2%), Pout > 48W permanently allowed, see Fig. 5-1 for output voltage regulation Absolute maximum input voltage with no damage to the power supply. Output might be off at this level. ±6% see Fig. 5-2 see Fig. 5-2 at 40A, symmetrical input, see Fig. 5-4 at 40A, symmetrical input, see Fig. 5-5 see Fig. 5-3 over the entire load range, see Fig. 5-3 0mF, 40A, see Fig. 5-3 40mF, 40A, see Fig. 5-3 A minimum voltage of 3x340Vac (XT40.241) or 3x408Vac (XT40.242) is required to turn the power supply on. The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit. The start-up delay for mains voltage interruptions up to 350ms is close to zero. In such cases, the power supply will immediately generate the output voltage once the mains voltage interruption is over. Do not use the buffer module UF20.241 as an accessory when longer mains interruptions need to be bridged (see chapter 24). Input Voltage Range Fig. 5-1 Output voltage vs. input voltage and input current Changes of the input voltage will be fully regulated within certain limits. The output voltage will only start to change proportionally to the input voltage with extreme under or over-voltages. The yellow LED reports an input voltage problem if exceeded by a window of ±15%. The maximum increase of the output voltage is limited to the 29.9V OVP level. This level will be kept regulated for 2s before the power supply will shut down and reports “Shut-down” by the red LED. VOUT POUT = 0W 28V 26V POUT > 48W (5%) 24V 22V VIN 20V XT40.241: 300 320 340 360 380 400 420 440 460 480Vac XT40.242: 360 384 408 432 456 480 504 528 552 576Vac Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 4/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series Fig. 5-2 Input voltage range VIN 400V Version: 3x 360Vac 480V Version: 3x 432Vac Start-up delay 3x 440Vac 3x 528Vac Fig. 5-4 Input current vs. output load 1.2 0.9 0.6 0.3 0 Power Factor, typ. 1.0 ) 0V 40 x 3 1( V) 80 .24 4 0 x 4 3 2( XT .24 40 T X 1.5 Rise Time Fig. 5-5 Power factor vs. output load Input Current per Phase, typ. 1.8A - 5% Output Voltage Overshoot fully regulated range Turn-on Shut-down POUT Fig. 5-3 Turn-on behavior definitions Intput Voltage 0.95 0.9 0.85 0.8 Output Current 0.75 Output Current 0.70 5 10 15 20 25 30 35 40 45 50A 5 10 15 20 25 30 35 40 45 50A 4. INPUT INRUSH CURRENT There is virtually no input inrush current surge as there are no electrolytic bulk-capacitors utilized on the input side of the power supply. The charging current into the EMI suppression capacitors is disregarded for the first millisecond after switch-on. Inrush current Inrush energy Inrush delay max. max. typ. XT40.241 4Apeak 5A2s 400ms XT40.242 4Apeak 5A2s 350ms -25°C to +70°C, see Fig. 6-1 -25°C to +70°C, see Fig. 6-1 see Fig. 6-1 Fig. 6-1 Input inrush current, typical behavior A: Inrush delay XT40.241: Input: Output: Ambient: 3x400Vac, only one phase shown 24V, 40A 25°C Upper curve: Input current 2A / DIV Medium curve: Input voltage 500V / DIV (measured between L and N) Lower curve: Output voltage 20V / DIV Time basis: 100ms / DIV Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 5/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 5. OUTPUT Output voltage Output voltage adjustment range Output current nom. Short-circuit current typ. Output power nom. Line regulation Load regulation max. max. max. max. max. typ. Ripple and noise voltage *) Output capacitance 24.1V none 40A 50A 180A nom. 960W 1200W ±2% 800mV 200mV 1500mVpp 50mVpp 20 000µF The output voltage is fixed. No adjustment possible continuous, see Fig. 7-1 up to 15s with full output voltage, see Fig. 7-1 load impedance 25mOhm, see Fig. 7-1 Note: The short-circuit current is available for 0.1s continuous up to 15s see Fig. 5-1 static value, 0A  40A  0A static value, 5A  40A  5A 20Hz-2kHz, 50Ohm 2kHz to 20MHz, 50Ohm *) The ripple and noise voltage mostly consist of a mains ripple with 300Hz (50Hz mains) or 360Hz (60Hz mains). The ripple and noise voltage can be reduced by the utilization of external capacitors. The power supply is also designed to support loads with a higher short-term current and power requirement. The short-term duration is firmware controlled by an output power manager. If the nominal output power is exceeded for a certain period of time which is defined in the zone A, B and C, the power supply responds with an automatic shutdown. Pressing the reset button or cycling the input power (10s off time is required) initiates an attempt to restart. If the fault has been cleared the device will operate normally. The short term power can be used periodically. See chapter 26.1 for further information. Fig. 7-1 Output voltage vs. output current, typ. A 15s VOUT C 0.1s B 5s 24V XT40.241 3x 340V 3x 400V 3x 460V 12V 0 20A 40A 50A 60A 80A 100A 120A 140A 160A XT40.242 3x 408V 3x 480V 3x 552V 180A 200A IOUT Zone A: 25% extra output power for typ. 15s Zone B: 100% higher output current for typ. 5s Zone C: Quick-acting shut-down after typ. 0.1s Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 6/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 6. HOLD-UP TIME Hold-up Time Hold-up Time typ. typ. typ. typ. min. min. min. min. XT40.241 2.0ms 1.8ms 4.0ms 3.6ms 1.6ms 1.45ms 3.2ms 2.9ms The energy is stored in the output capacitor. As soon as the input is turned off, the output capacitor will be discharged and the voltage will dissipate according to the curves in Fig. 8-2. The lighter the load, the longer the hold-up time. Half the load means twice the hold-up time. The hold-up time depends on the load characteristic. The curves below show the hold-up time for a load with a resistive and a constant power characteristic. The hold-up time is defined as the period of time when the input is turned off and until the output voltage falls below 24V –15% (20.4V). This value is defined in the IEC61131-2 as the lower limit for the supplying voltage. XT40.242 2.0ms 1.8ms 4.0ms 3.6ms 1.6ms 1.45ms 3.2ms 2.9ms 40A, resistive load, see Fig. 8-2 40A, constant power load, see Fig. 8-2 20A, resistive load 20A, constant power load 40A, resistive load, see Fig. 8-2 40A, constant power load, see Fig. 8-2 20A, resistive load 20A, constant power load Fig. 8-1 Hold-up time, definitions Zero Transition Intput Voltage Output Voltage Holdup Time -15% Fig. 8-2 Hold-up time vs. input voltage VOUT 24V 40A, constant power load, min. 22V 40A, constant power load, typ. 20.4V 40A, resistive load, min. 40A, resistive load, typ. 18V 16V 14V T 12V 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0ms Note: At no load, the hold-up time can be up to one minute. The green DC-ok LED is on during this time. Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 7/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 7. EFFICIENCY AND POWER LOSSES Efficiency Power losses XT40.241 95.5% 45.2W 18.2W typ. typ. typ. XT40.242 95.5% 45.2W 18.2W Fig. 9-1 Efficiency vs. output current 40A 40A 0A Fig. 9-2 Losses vs. output current Power Losses Efficiency 50W 96% 95 94 93 92 91 90 89 88 40 30 20 10 Output Current 5 10 15 20 25 30 35 40A Fig. 9-3 Efficiency vs. input voltage, 24V, 40A 95.8% Efficiency 95.6 XT40.241 XT40.242 Output Current 0 0 52W 95.2 46 95.0 44 94.8 42 350 400 450 Power Losses 50 48 Input Voltage XT40.241 XT40.242 Input Voltage 40 500 3x550Vac 8 12 16 20 24 28 32 36 40A Fig. 9-4 Losses vs. input voltage, 24V, 40A 95.4 94.6 4 350 400 450 500 3x550Vac Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 8/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 8. FUNCTIONAL DIAGRAM Fig. 10-1 Functional diagram L1 L2 L3 Input Filter Input Rectifier Input Voltage Monitor Active Transient Blocker Semiregulated Power Converter Output Filter Temp. Shutdown OverVoltage Protection Output Voltage Monitor + - DC-ok LED Warning LED Output Power Manager Shut-down LED Reset 9. FRONT SIDE AND USER ELEMENTS Fig. 11-1 Front side of XT40.241 Output Terminals Large screw terminal + Positive output - Negative (return) output See chapter 12 “Terminals and Wiring” to choose appropriate wire size. Input Terminals Screw terminals L1, L2, L3: Line inputs PE (Protective Earth) input DC-ok LED (green) Indicates a normal operation. The LED is on if the output voltage is higher than 21.6V. Warning LED (yellow) - A steady-state light indicates an output current higher than the nominal current and that the internal shutdown timer is running. - A double flash indicates a phase-loss or too low / too high input voltage. (XT40.241: < 3x333Vac or > 3x467Vac XT40.242: < 3x400Vac or > 3x560Vac) - A fast flash warns of an impending temperature shut-down. A shut-down can be expected within 10 minutes, if the ambient temperature or the load current stays constant. Shut-down LED (red) and reset button The red LED flashes when the device has shut down. Pressing the reset button or cycling the input power (10s required) initiates a restart. If the fault has been cleared the device will operate normally. Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 9/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 10. TERMINALS AND WIRING Use appropriate copper cables that are designed for a minimum operating temperatures of 60°C (for ambient up to 45°C) and 75°C (for ambient up to 60°C). Follow national installation codes and regulations! Ensure that all strands of a stranded wire enter the terminal connection! Do not use the power supply without PE (Ground) connection! Up to two stranded wires with the same cross section are permitted in one connection point (except PE wire). Ferrules are allowed, but not required. Input Screw terminal 0.5-6mm2 0.5-4mm2 20-10 AWG 7mm / 0.26inch 0.8Nm / 7lb.inch Type Solid wire Stranded wire American wire gauge Wire stripping length Recommended tightening torque Output Screw terminal 0.5-16mm2 0.5-10mm2 22-8 AWG 12mm / 0.5inch 1.2Nm / 10.6lb.inch 11. RELIABILITY Lifetime expectancy MTBF SN 29500, IEC 61709 MTBF MIL HDBK 217F min. min. min. 51 000h t.b.d. 142 000h 529 000h 959 000h 206 000h 276 000h 40°C, 24.1V, 40A 40°C, 24.1V, 20A 25°C, 24.1V, 40A 40°C, 24.1V, 40A 25°C, 24.1V, 40A 40°C, 24.1V, 40A, Ground Benign GB40 25°C, 24.1V, 40A, Ground Benign GB25 The Lifetime expectancy shown in the table above indicates the operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the capacitor’s manufacturer specification. The prediction model allows a calculation of up to 15 years from date of shipment. MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product. Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 10/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 12. EMC The power supply is suitable for applications in industrial environments as well as in residential, commercial and light industry environments without any restrictions. The CE mark is in conformance with EMC guideline 89/336/EEC and 93/68/EEC and the low-voltage directive (LVD) 73/23/EWG. A detailed EMC report is available on request. EMC Immunity Electrostatic discharge Electromagnetic RF field Fast transients (Burst) Surge voltage on input Surge voltage on output Conducted disturbance Mains voltage dips Powerful transients EN 61000-6-1 and EN 61000-6-2 Contact discharge EN 61000-4-2 Air discharge EN 61000-4-3 80MHz-1GHz Input lines EN 61000-4-4 Output lines L1  L2, L2  L3, L1  L3 EN 61000-4-5 L1 / L2 / L3  PE +EN 61000-4-5 + / -  PE EN 61000-4-6 0.15-80MHz 0% of 400Vac EN 61000-4-11 40% of 400Vac 70% of 100Vac 0% of 480Vac 40% of 480Vac 70% of 480Vac VDE 0160 over entire load range Generic standards 8kV 15kV 10V/m 4kV 2kV 2kV 4kV 500V 500V 10V 20ms 200ms 500ms 20ms 200ms 500ms 1300V, 1.3ms Criterion A Criterion A Criterion A Criterion A Criterion A Criterion A Criterion A Criterion A Criterion A Criterion A Criterion B Criterion C Criterion C Criterion B Criterion C Criterion C Criterion D Criteria: A: Power supply shows normal operation behavior within the defined limits. B: During the mains voltage dip, the output voltage will decrease according to curves in the section “Hold-up Time”. The unit works in normal mode once the voltage dip is over. If criteria A is required, use one or two buffer modules UF20.241 in addition to the XT40 power supply. C: Temporary loss of function is possible. Power supply might shut-down and restarts by itself. No damages or hazards for the power supply will occur. D: The input transient blocker opens and the main converter is without input power during such transients. The output voltage decreases similar as described in the hold-up time section during such an event. EMC Emission Conducted emission EN 61000-6-3 and EN 61000-6-4 Generic standards EN 55011, EN 55032, FCC Part 15, CISPR 11, CISPR 32 Class B, input lines EN 55032 Class B, output lines Radiated emission EN 55011, EN 55032 Class B Harmonic input current EN 61000-3-2 Fulfilled, active PFC Voltage fluctuations, flicker EN 61000-3-3 Fulfilled This device complies with FCC Part 15 rules. Operation is subjected to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Switching Frequency Switching frequency 36kHz nearly constant Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 11/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 13. ENVIRONMENT Operational temperature Output de-rating Storage temperature Humidity -25°C to +70°C (-13°F to 158°F) 24W/°C -40 to +85°C (-40°F to 185°F) 5 to 95% r.H. 2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g 2 hours / axis 0.5m2(s3) 2 hours / axis 15g 6ms, 10g 11ms 3 bumps / direction, 18 bumps in total 0 to 6000m (0 to 20 000ft) Vibration sinusoidal Vibration random Shock Altitude Output de-rating (for altitude) Over-voltage category 60W/1000m or 5°C/1000m III II 2 Degree of pollution Fig. 15-1 Output current vs. ambient temp., Allowed Output Current IEC 60068-2-6 IEC 60068-2-64 IEC 60068-2-27 Reduce output power or ambient temperature above 2000m sea level. above 2000m, see Fig. 15-2 EN 50178, altitudes up to 2000m Altitudes from 2000m to 6000m EN 50178, non conductive Fig. 15-2 Output current vs. altitude Allowed Output Current 40A 40A 30 30 20 20 10 10 0 -25 reduce output power above +60°C 60-70°C (140°F to 158°F), see Fig. 15-1 storage and transportation no condensation allowed Ambient Temperature 0 20 40 60 70°C B C A A... Tamb < 60°C B... Tamb < 50°C C... Tamb < 40°C Altitude 0 0 2000 4000 6000m The ambient temperature is defined 2cm below the unit. Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 12/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 14. PROTECTION FEATURES Output protection Output over-voltage protection Electronically protected against overload, no load and short circuits *) In case of an internal power supply failure, a redundant max. 29.9Vdc circuit limits the maximum output voltage. The output shuts-down and automatically attempts to restart. typ. 3x 470Vac XT40.241 typ. 3x 560Vac XT40.242 IP 20 EN/IEC 60529 > 3.5mm e.g. screws, small parts yes output shut-down, reset required MOV (Metal Oxide Varistor) and active transient blocker not included See section 26.4 Input overvoltage shut-down Degree of protection Penetration protection Over-temperature protection Input transient protection Internal input fuse *) An audible noise may be heard during a no load, overload or short circuit event. 15. SAFETY Input / output separation SELV IEC/EN 60950-1 PELV EN 60204-1, EN 50178, IEC 60364-4-41 double or reinforced insulation I PE (Protective Earth) connection required > 5MOhm input to output, 500Vdc < 0.1Ohm between housing and PE terminal typ. 0.30mA XT40.241: 3x400V, 50Hz, TN mains < 0.35mA XT40.241: 3x440V, 50Hz, TN mains typ. 0.40mA XT40.242: 3x480V, 60Hz, TN mains < 0.45mA XT40.242: 3x524V, 60Hz, TN mains Class of protection Isolation resistance PE resistance Touch current (leakage current) 16. DIELECTRIC STRENGTH Type test 60s A 2500Vac B 3000Vac C 500Vac Factory test 5s 2500Vac 2500Vac 500Vac Field test 5s 2000Vac 2000Vac 500Vac Fig. 18-1 Dielectric strength Input L1 L2 L3 B A Earth Output + C - Type tests and factory tests: Conducted by the manufacturer. Do not repeat these test in the field! Rules for field test: Use appropriate test equipment which applies the voltage with a slow ramp! Connect L1, L2 and L3 together as well as all output poles. The output voltage is floating and has no ohmic connection to ground. Grounding of output allowed. To fulfill the PELV requirements according to EN60204-1 paragraph 6.4.1, PULS recommend that either the + pole or the – pole shall be connected to the protective earth system. This helps to avoid situations in which a load starts unexpectedly or cannot be switched off when an unnoticed ground fault occurs. Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 13/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 17. APPROVALS AND FULFILLED STANDARD UL Certificate Listed equipment for category NMTR - Industrial Control Equipment Applicable for US and Canada E-File: E198865 CB Scheme Certificate General safety requirements for Information Technology Equipment (ITE) UL 508 IEC 60950-1 UL Certificate Recognized component for category QQGQ - Information Technology Equipment (ITE) Applicable for US and Canada E-File: E137006 Manufacturer's Declaration (Online Document) IEC 60068-2-60 - Environmental Tests, Flowing Mixed Gas Corrosion Test Test Ke - Method 4 H2S: 10ppb NO2: 200ppb Cl2: 10ppb SO2: 200ppb Test Duration: 3 weeks, which simulates a service life of at least 10 years Manufacturer's Declaration (Online Document) Airborne Contaminants Corrosion Test Severity Level: G3 Harsh H2S: 100ppb NOx: 1250ppb Cl2: 20ppb SO2: 300ppb Test Duration: 3 weeks, which simulates a service life of at least 10 years. Paint Wetting Impairment Substances Test (or LABS-Test) Tested for Zone 2 and test class C1 according to VDMA 24364-C1-L/W for solvents and water-based paints UL 60950-1 Corrosion IEC 60068-2-60 Method 4 Corrosion G3-ISA-71.04 VDMA 24364 18. REGULATORY COMPLIANCE EU Declaration of Conformity REACH Directive EAC TR Registration The CE mark indicates conformance with the - EMC directive - Low-voltage directive (LVD) - RoHS directive Manufacturer's Statement EU-Directive regarding the Registration, Evaluation, Authorisation and Restriction of Chemicals EAC Certificate EAC EurAsian Conformity - Registration Russia, Kazakhstan and Belarus 8504408200, 8504409000 Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 14/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 19. PHYSICAL DIMENSIONS AND WEIGHT Weight DIN-Rail 1400g / 3.09lb Use 35mm DIN-rails according to EN 60715 or EN 50022 with a height of 7.5 or 15mm. The DIN-rail height must be added to the depth (157mm) to calculate the total required installation depth. CAD files with mechanical data can be downloaded at www.pulspower.com Fig. 22-1 Front view Fig. 22-2 Side view 20. INSTALLATION AND OPERATION INSTRUCTIONS Mounting and installation: Output terminal must be located on top and input terminal on the bottom. For other orientations see section 26.12. An appropriate electrical and fire end-product enclosure needs to be considered in the end use application. Cooling: Convection cooled, no forced air cooling required. Do not block ventilation grill by more than 30%! Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. If the adjacent device is a heat source, 15mm clearance are recommended. Risk of electrical shock, fire, personal injury or death! Do not use the unit without proper earth connection (Protective Earth). Use the pin on the terminal block for earth connection and not one of the screws on the housing. Turn power off before working on the power supply. Protect against inadvertent re-powering. Make sure the wiring is correct by following all local and national codes. Do not open, modify or repair the unit. Use caution to prevent any foreign objects from entering into the housing. Do not use in wet locations or in areas where moisture or condensation can be expected Service parts: The unit does not contain any field replaceable parts. If damage or malfunctioning should occur, immediately turn power off and send the unit back to the factory for inspection! Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 15/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 21. ACCESSORIES Buffer module UF20.241 This buffer unit is a supplementary device for DC24V power supplies. It delivers power to bridge typical mains failures or extends the hold-up time after turn-off of the AC power. In times when the power supply provides sufficient voltages, the buffer unit stores energy in integrated electrolytic capacitors. In case of mains voltage fault, this energy is released again in a regulated process. Fig. 24-1 Buffer module UF 20.241 Fig. 24-2 Wiring diagram XT40 and UF20.241 The buffer unit does not require any control wiring. It can be added in parallel to the load circuit at any given point. Buffer units can be added in parallel to increase the output ampacity or the holdup time. Power Supply AC Buffer Unit(s) Load + - DC Do not use the buffer module to bridge mains interruptions which are longer than typ. 350ms. Once the mains is off for longer than typ. 350ms, the XT power supply needs an additional 1s to restart again. 22. COMPARISON BETWEEN THE XT40, A TRANSFORMER AND A TRADITIONAL SWITCHED-MODE POWER SUPPLY XT40 Semiregulated power supply Input voltage range Inrush current surge Hold-up time Phase-loss operation Efficiency Output voltage regulation Output adjustment range Ripple & noise voltage Error diagnostics Harmonic distortion (PFC) EMC Ease of installation Size Weight + ++ +++ + ++ + ++ ++ +++ +++ +++…very, very good Traditional switched-mode power supply Transformer power supply ++ + + + ++ ++ ++ ++ ++ + ++ ++ ++ + + - ++…very good +…good -…poor Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 16/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 23. APPLICATION NOTES 23.1. PERIODICAL PEAK POWER CAPABILITY Fig. 26-Periodical peak power compatibility. The short term power can be used periodically. The duration of the peak power (TP) must be shorter than 15s. The time between two peak power pulses must be three times longer than the duration of the preceding pulse length. POUT PNOM T TP > 3x TP 125% 100% t 23.2. CHARGING OF BATTERIES The power supply shall not be used to charge batteries. Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 17/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 23.3. OUTPUT CIRCUIT BREAKERS Standard miniature circuit breakers (MCB`s or UL 1077 supplementary breakers) can be used for branch protection but ensure, that the MCB is rated for DC voltage too. The following tests show which circuit breakers the power supply typically will trip. Circuit breakers have huge tolerances in their tripping behavior. Therefore, these typical tests can only be used as a recommendation or for comparing two different power supplies. Furthermore, the loop impedance has a major influence on whether a breaker trips or not. Two tests were performed, representing typical situations: Test 1: Short circuit with S1 on the power supply end of the cable (loop impedance approx. 20mOhm) Fig. 26-1 Branch protectors, test circuit 1 Power Supply AC Parameters: Circuit Breaker I Input voltage: + + The following circuit breaker tripped during the test: Load S1 DC - 3x400Vac, load current: 0A A- or Z- Characteristic:: B- Characteristic: C- Characteristic: - equal or smaller 25A *) equal or smaller 32A *) equal or smaller 20A *) Test 2: Short circuit with S1 on the load end (additional impedance included; represents longer load wire length). Parameters: Fig. 26-2 Branch protectors, test circuit 2 Circuit Breaker I Power Supply AC + Input voltage: The following circuit breaker tripped during the test: R A- or Z- Characteristic:: B- Characteristic: C- Characteristic: + Load S1 DC - 3x400Vac, load current: 0A - ≤ 25A and R= 50mOhm *) ≤ 25A and R= 50mOhm *) ≤ 20A and R= 82mOhm *) What does this resistance mean in wire length? 50mOhm 1.0mm2 2.8m 1.5mm2 4.2m 2.5mm2 7.0m 4.0mm2 11.1m 6.0mm2 16.7m 10mm2 27.9m 82mOhm 4.6m 6.9m 11.4m 18.3m 27.4m 45.7m *) A list of the circuit breakers under test is available on request. Example: Which wire gauge must be used at a length of 10m before a B-Characteristic circuit breaker with 25A will trip? Answer: A 25A B-Characteristic circuit breaker requires a loop impedance of less than 50mOhm based on the test results. The wire length table shows that a length of 11.1m with a cross section of 4.0mm2 has an impedance of 50mOhm. A wire not smaller than 4.0mm2 shall be used. Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 18/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 23.4. EXTERNAL INPUT PROTECTION The power supply has no internal input fuses included. The unit is tested and approved for branch circuits up to 16A (U.S.A 15A). External protection is only required if the supplying branch has an ampacity greater than this. In some countries local regulations might apply so check all local codes and requirements. If an external fuse is necessary or utilized, minimum requirements need to be considered to avoid nuisance tripping of the fuse. Ampacity max. min. B-Characteristic 20A 6A C-Characteristic 20A 3A 23.5. BACK-FEEDING LOADS Loads such as decelerating motors and inductors can feed voltage back to the power supply. This feature is also called return voltage immunity or resistance against Back- E.M.F. (Electro Magnetic Force). This power supply is resistant and does not show adverse effects when a load feeds back voltage to the power supply. It does not matter, whether the power supply is on or off. If the power supply is fully loaded after a return-feeding event, the output voltage can dip to 21V for approx 20ms. The maximum allowed feed back voltage is 28.9Vdc. The absorbing energy can be calculated according to the built-in large sized output capacitor which is specified in chapter 7. 23.6. PARALLEL USE TO INCREASE OUTPUT POWER The XT40 Series of power supplies shall not be paralleled to increase the output power. 23.7. PARALLEL USE FOR REDUNDANCY Power supplies can be paralleled for a 1+1 redundancy to gain a higher system availability and reliability. Redundant systems require a certain amount of extra power to support the load in case one power supply unit fails. The simplest way is to put two X-Series power supplies in parallel which is called a 1+1 redundancy. In case one power supply unit fails, the other one is automatically able to support the load current without any interruption. Please note: This simple way to build a redundant system does not cover failures such as an internal short circuit on the secondary side of the power supply. In such a condition, the shorted unit becomes a load for the other power supplies and the output voltage can not be maintained. This can be avoided by utilizing decoupling diodes which are included in the SilverLine redundancy module SLR01. Recommendations for building redundant power systems: a) Use separate input fuses for each power supply. b) Monitor the individual power supply units. A DC-ok LED and a DC-ok contact is included in the redundancy module SLR01and can report a faulty unit. Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 19/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 23.8. SERIES OPERATION The power supplies of the X-Series can be put in series to increase the output voltage. Fig. 26-3 Schematic for series operation Unit A AC DC + + Unit B AC DC + - - Load Earth (see notes) Installation notes for use in series: a) It is possible to connect as many units in series as needed, providing the sum of the output voltage does not exceed 150Vdc. b) Voltages with a potential above 60Vdc are no longer rated SELV and can be hazardous in some situations. Such voltages must be installed with a protection to make the unit touch-safe. c) For serial operation use power supplies of the same type. d) Earthing of the output is required when the sum of the output voltage is above 60Vdc. e) Keep an installation clearance of 15mm (left/right) between two power supplies and avoid installing the power supplies on top of each other. Note: Avoid return voltage (e.g. from a decelerating motor or battery) which is applied to the output terminals. 23.9. INDUCTIVE AND CAPACITIVE LOADS The unit is designed to supply any kind of loads, including inductive loads or capacitive loads with a capacity of up to160mF. 23.10. LOSS OF ONE INPUT PHASE The unit protects itself against a loss of one input phase and does not require an external protection device. A phase-loss operation is possible for output currents below 8A. Above this level, the yellow LED indicates an impending shut-down. If the missing phase does not recover, the unit switches off after 3.5s. Pressing the reset button or cycling the input power (10s required) initiates a restart. Please note that the input current and the output ripple are higher during the time when one phase is missing. 23.11. USE IN A TIGHTLY SEALED ENCLOSURE When the power supply is installed in a tightly sealed enclosure, the temperature inside the enclosure will be higher than outside. The inside temperature defines the ambient temperature for the power supply. Results from such an installation: Power supply is placed in the middle of the box, no other heat producing equipment inside the box Enclosure: Load: Input: Temperature inside the box: Temperature outside the box: Temperature rise: Rittal Typ IP66 Box PK 9519 100, plastic, 180x180x165mm 24V, 32A (=80% of the rated current); load is placed outside the box 3x400Vac 54.9°C (in the middle of the right side of the power supply with a distance of 2cm) 25.7°C 29.7K Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 20/21 XT40.241, XT40.242 24V, 40A, THREE-PHASE INPUT – X-Series 23.12. MOUNTING ORIENTATIONS Mounting orientations other than input terminals on the bottom and output on the top require a reduction in continuous output power or a limitation in the max. allowed ambient temperature. The amount of reduction defines the lifetime expectancy of the power supply. Therefore, two different derating curves for continuous operation can be found below: Curve A1 Curve A2 Recommended output current to achieve a minimum lifetime expectancy of 50 000h at 40°C ambient. Max allowed output current for a safe operation (results approx. in half the lifetime expectancy of A1). Fig. 26-4 Mounting Orientation A Standard Orientation Output Current 40A OUTPUT A1 30 Power Supply 20 10 Ambient Temperature 0 INPUT 10 Fig. 26-5 Mounting Orientation B (Upside down) 20 30 40 60°C 50 Output Current 40A INPUT 30 A2 Power Supply 20 A1 OUTPUT 0 10 Ambient Temperature 10 Fig. 26-6 Mounting Orientation C (Table-top mounting) 20 30 50 40 60°C Output Current 40A 30 A2 A1 20 10 Ambient Temperature 0 10 50 40 60°C 40A OUTPUT Power Supply 30 A2 20 A1 10 Ambient Temperature 0 10 20 30 40 50 60°C Output Current 30 INPUT Power Supply 40A OUTPUT Fig. 26-8 Mounting Orientation E (Horizontal ccw) 30 Output Current INPUT Fig. 26-7 Mounting Orientation D (Horizontal cw) 20 A2 A1 20 10 Ambient Temperature 0 10 20 30 40 50 60°C Nov. 2020 / Rev. 1.1 DS-XT40.24x-EN All parameters are specified at 24V 40A, 3x400Vac (XT40.241) or 3x480Vac (XT40.242), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 21/21
XT40.241 价格&库存

很抱歉,暂时无法提供与“XT40.241”相匹配的价格&库存,您可以联系我们找货

免费人工找货