0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PQM1-S12-S5-M-TR

PQM1-S12-S5-M-TR

  • 厂商:

    CUIDEVICES

  • 封装:

    -

  • 描述:

    DC/DC CONVERTER 5V 1W

  • 数据手册
  • 价格&库存
PQM1-S12-S5-M-TR 数据手册
Additional Resources: Product Page | 3D Model | PCB Footprint date 08/03/2022 page 1 of 6 SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER FEATURES • • • • • • • • • 1 W isolated output smaller package single regulated output 1,500 Vdc isolation continuous short circuit protection extended temperature range (-40~85°C) high efficiency at light load efficiency up to 75% EN 62368-1 MODEL input voltage output voltage output current output power ripple and noise1 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) typ (mVp-p) typ (%) PQM1-S5-S3-M 5 4.75~5.25 3.3 25 243 0.8 50 58 PQM1-S5-S5-M 5 4.75~5.25 5 20 200 1 50 72 PQM1-S5-S9-M 5 4.75~5.25 9 12 111 1 50 74 PQM1-S5-S12-M 5 4.75~5.25 12 9 84 1 50 73 PQM1-S5-S15-M* 5 4.75~5.25 15 7 67 1 50 74 PQM1-S12-S5-M 12 11.4~12.6 5 20 200 1 50 73 PQM1-S12-S9-M 12 11.4~12.6 9 12 111 1 50 74 PQM1-S12-S12-M 12 11.4~12.6 12 9 84 1 50 73 PQM1-S12-S15-M 12 11.4~12.6 15 7 67 1 50 75 PQM1-S24-S5-M 24 22.8~25.2 5 20 200 1 50 65 PQM1-S24-S9-M 24 22.8~25.2 9 12 111 1 50 74 PQM1-S24-S12-M 24 22.8~25.2 12 9 84 1 50 73 PQM1-S24-S15-M 24 22.8~25.2 15 7 67 1 50 74 Note: 1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output. *. Discontinued model. PART NUMBER KEY PQM1 - SXX - S XX - M - X Base Number Input Voltage Output S = single cui.com Output Voltage Packaging Style "blank" = tube TR = tape & reel Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER date 08/03/2022 │ page 2 of 6 INPUT parameter conditions/description min typ max units operating input voltage 5 Vdc input models 12 Vdc input models 24 Vdc input models 4.75 11.4 22.8 5 12 24 5.25 12.6 25.2 Vdc Vdc Vdc surge voltage for maximum of 1 second 5 Vdc input models 12 Vdc input models 24 Vdc input models -0.7 -0.7 -0.7 9 18 30 Vdc Vdc Vdc filter capacitance filter max units ±0.25 % OUTPUT parameter conditions/description min line regulation for Vin change of 1% load regulation measured from 10% load to full load 3.3 Vdc output models all other models voltage accuracy at 100% load switching frequency at 100% load, nominal input voltage temperature coefficient at 100% load typ 3 1 100 % % ±3 % 300 kHz ±0.03 %/°C PROTECTIONS parameter conditions/description short circuit protection continuous, automatic recovery min typ max units min typ max units SAFETY AND COMPLIANCE parameter conditions/description isolation voltage input to output for 1 minute at 1 mA max. 1,500 Vdc isolation resistance input to output at 500 Vdc 1,000 MΩ safety approvals2 certified to 62368-1: EN conducted emissions CISPR22/EN55022 class B (external circuit required, see Figure 1) radiated emissions CISPR22/EN55022 class B (external circuit required, see Figure 1) ESD IEC/EN61000-4-2, class B, contact ± 8kV MTBF as per MIL-HDBK-217F @ 25°C RoHS 2011/65/EU Note: 3,500,000 hours 2. CE mark doesn't apply to 9 Vdc output models. ENVIRONMENTAL parameter conditions/description min operating temperature see derating curve storage temperature storage humidity non-condensing temperature rise at full load, Ta = 25°C typ max units -40 85 °C -55 125 °C 95 25 cui.com % °C Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER date 08/03/2022 │ page 3 of 6 SOLDERABILITY parameter conditions/description max units hand soldering 1.5 mm from case for 10 seconds min 300 °C reflow soldering see reflow soldering profile 245 °C max units Temperature(°C) 2 50 2 45 2 17 2 00 typ °C ( M a x .) P e a k . Te m p 2 4 5  6 0 S e c M ax ( > 2 1 7°C ) 1 50 1 00 50 0 Time (sec.) MECHANICAL parameter conditions/description dimensions 15.24 x 11.20 x 7.25 (0.600 x 0.441 x 0.285 inch) min case material epoxy resin (UL94-V0) weight typ mm 2.0 g MECHANICAL DRAWING units: mm[inch] tolerance: ±0.25[±0.010] pin section tolerance: ±0.10[±0.004] PIN CONNECTIONS PIN FUNCTION 1 GND 2 Vin 4/5 0V 7 +Vo 10 NC NC: No Connection Top View Top View PCB Layout Side View Front View cui.com Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER date 08/03/2022 │ page 4 of 6 DERATING CURVE EMC RECOMMENDED CIRCUIT Figure 1 Table 1 Recommended external circuit components cui.com Vout (Vdc) C1 C2 LDM 3.3 4.7μF/50V 10μF 6.8μH 5 4.7μF/50V 10μF 6.8μH 9 4.7μF/50V 4.7μF 6.8μH 12 4.7μF/50V 2.2μF 6.8μH 15 4.7μF/50V 1μF 6.8μH Additional Resources: Product Page | 3D Model | PCB Footprint CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER date 08/03/2022 │ page 5 of 6 APPLICATION NOTES 1. Output load requirement To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load. 2. Overload Protection Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add this is to add a circuit breaker to the circuit. 3. Recommended circuit If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low ESR (see Figure 2 & Table 2). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance must be less than the maximum capacitive load (see Table 3). Figure 2 Table 2 Vin (Vdc) Cin (µF) Vo (Vdc) Cout (µF) Vout (Vdc) Max. Capacitive Load (μF) 5 4.7 3.3 10 3.3 220 12 2.2 5 10 5 220 24 1 9 4.7 9 220 -- -- 12 2.2 12 220 -- -- 15 1 15 220 Note: Note: Table 3 It’s not recommended to connect any external capacitors in applications with less than 0.5 watt output. 1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed. 2. Max. capacitive load tested at input voltage range and full load. 3. All specifications measured at: Ta=25°C, humidity
PQM1-S12-S5-M-TR 价格&库存

很抱歉,暂时无法提供与“PQM1-S12-S5-M-TR”相匹配的价格&库存,您可以联系我们找货

免费人工找货