74AUP1G16
Low-power buffer
Rev. 2 — 7 October 2016
Product data sheet
1. General description
The 74AUP1G16 provides a low-power, low-voltage single buffer.
Schmitt trigger action at all inputs makes the circuit tolerant to slower input rise and fall
times across the entire VCC range from 0.8 V to 3.6 V.
This device ensures a very low static and dynamic power consumption across the entire
VCC range from 0.8 V to 3.6 V.
This device is fully specified for partial power-down applications using IOFF.
The IOFF circuitry disables the output, preventing the damaging backflow current through
the device when it is powered down.
2. Features and benefits
Wide supply voltage range from 0.8 V to 3.6 V
High noise immunity
Complies with JEDEC standards:
JESD8-12 (0.8 V to 1.3 V)
JESD8-11 (0.9 V to 1.65 V)
JESD8-7 (1.2 V to 1.95 V)
JESD8-5 (1.8 V to 2.7 V)
JESD8-B (2.7 V to 3.6 V)
ESD protection:
HBM JESD22-A114F Class 3A exceeds 5000 V
MM JESD22-A115-A exceeds 200 V
CDM JESD22-C101E exceeds 1000 V
Low static power consumption; ICC = 0.9 A (maximum)
Latch-up performance exceeds 100 mA per JESD 78 Class II
Inputs accept voltages up to 3.6 V
Low noise overshoot and undershoot < 10 % of VCC
IOFF circuitry provides partial power-down mode operation
Multiple package options
Specified from 40 C to +85 C and 40 C to +125 C
74AUP1G16
Nexperia
Low-power buffer
3. Ordering information
Table 1.
Ordering information
Type number
Package
Temperature range
Name
Description
Version
74AUP1G16GW
40 C to +125 C
TSSOP5
plastic thin shrink small outline package; 5 leads;
body width 1.25 mm
SOT353-1
74AUP1G16GM
40 C to +125 C
XSON6
plastic extremely thin small outline package; no leads; SOT886
6 terminals; body 1 1.45 0.5 mm
74AUP1G16GF
40 C to +125 C
XSON6
plastic extremely thin small outline package; no leads; SOT891
6 terminals; body 1 1 0.5 mm
4. Marking
Table 2.
Marking
Type number
Marking code[1]
74AUP1G16GW
5N
74AUP1G16GM
5N
74AUP1G16GF
5N
[1]
The pin 1 indicator is located on the lower left corner of the device, below the marking code.
5. Functional diagram
$
<
$
DDF
Fig 1.
Logic symbol
74AUP1G16
Product data sheet
<
DDF
Fig 2.
IEC logic symbol
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 7 October 2016
DDF
Fig 3.
Logic diagram
©
Nexperia B.V. 2017. All rights reserved
2 of 17
74AUP1G16
Nexperia
Low-power buffer
6. Pinning information
6.1 Pinning
$83*
QF
$
*1'
$83*
9&&
QF
9&&
$
QF
*1'
<
<
DDD
7UDQVSDUHQWWRSYLHZ
DDD
Fig 4.
Pin configuration SOT353-1 (TSSOP5)
Fig 5.
Pin configuration SOT886 and SOT891
(XSON6)
6.2 Pin description
Table 3.
Pin description
Symbol
Pin
Description
TSSOP5
XSON6
n.c.
1
1
not connected
A
2
2
data input
GND
3
3
ground (0 V)
Y
4
4
data output
n.c.
-
5
not connected
VCC
5
6
supply voltage
7. Functional description
Table 4.
Function table[1]
Input
Output
A
Y
L
L
H
H
[1]
H = HIGH voltage level;
L = LOW voltage level.
74AUP1G16
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 7 October 2016
©
Nexperia B.V. 2017. All rights reserved
3 of 17
74AUP1G16
Nexperia
Low-power buffer
8. Limiting values
Table 5.
Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol
Parameter
VCC
supply voltage
IIK
input clamping current
VI
input voltage
IOK
output clamping current
Conditions
VI < 0 V
[1]
VO < 0 V
[1]
Min
Max
Unit
0.5
+4.6
V
50
-
0.5
+4.6
50
-
0.5
+4.6
mA
V
mA
VO
output voltage
Active mode and Power-down mode
IO
output current
VO = 0 V to VCC
-
20
mA
ICC
supply current
-
+50
mA
IGND
ground current
50
-
mA
Tstg
storage temperature
65
+150
C
-
250
mW
total power dissipation
Ptot
[1]
[2]
Tamb = 40 C to +125 C
[2]
V
The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
For TSSOP5 packages: above 87.5 C the value of Ptot derates linearly with 4.0 mW/K.
For XSON6 packages: above 118 C the value of Ptot derates linearly with 7.8 mW/K.
9. Recommended operating conditions
Table 6.
Recommended operating conditions
Symbol
Parameter
VCC
supply voltage
VI
input voltage
VO
output voltage
Conditions
Tamb
ambient temperature
t/V
input transition rise and fall rate
74AUP1G16
Product data sheet
Min
Max
Unit
0.8
3.6
V
0
3.6
V
Active mode
0
VCC
V
Power-down mode; VCC = 0 V
0
3.6
V
40
+125
C
0
200
ns/V
VCC = 0.8 V to 3.6 V
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 7 October 2016
©
Nexperia B.V. 2017. All rights reserved
4 of 17
74AUP1G16
Nexperia
Low-power buffer
10. Static characteristics
Table 7.
Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
Typ
Max
Unit
VCC = 0.8 V
0.70 VCC
-
-
V
VCC = 0.9 V to 1.95 V
0.65 VCC
-
-
V
VCC = 2.3 V to 2.7 V
1.6
-
-
V
VCC = 3.0 V to 3.6 V
2.0
-
-
V
VCC = 0.8 V
-
-
0.30 VCC V
VCC = 0.9 V to 1.95 V
-
-
0.35 VCC V
VCC = 2.3 V to 2.7 V
-
-
0.7
V
VCC = 3.0 V to 3.6 V
-
-
0.9
V
IO = 20 A; VCC = 0.8 V to 3.6 V
VCC 0.1
-
-
V
IO = 1.1 mA; VCC = 1.1 V
0.75 VCC
-
-
V
IO = 1.7 mA; VCC = 1.4 V
1.11
-
-
V
Tamb = 25 C
VIH
VIL
VOH
VOL
HIGH-level input voltage
LOW-level input voltage
HIGH-level output voltage
LOW-level output voltage
VI = VIH or VIL
IO = 1.9 mA; VCC = 1.65 V
1.32
-
-
V
IO = 2.3 mA; VCC = 2.3 V
2.05
-
-
V
IO = 3.1 mA; VCC = 2.3 V
1.9
-
-
V
IO = 2.7 mA; VCC = 3.0 V
2.72
-
-
V
IO = 4.0 mA; VCC = 3.0 V
2.6
-
-
V
IO = 20 A; VCC = 0.8 V to 3.6 V
-
-
0.1
V
IO = 1.1 mA; VCC = 1.1 V
-
-
VI = VIH or VIL
0.3 VCC V
IO = 1.7 mA; VCC = 1.4 V
-
-
0.31
V
IO = 1.9 mA; VCC = 1.65 V
-
-
0.31
V
IO = 2.3 mA; VCC = 2.3 V
-
-
0.31
V
IO = 3.1 mA; VCC = 2.3 V
-
-
0.44
V
IO = 2.7 mA; VCC = 3.0 V
-
-
0.31
V
IO = 4.0 mA; VCC = 3.0 V
-
-
0.44
V
II
input leakage current
VI = GND to 3.6 V; VCC = 0 V to 3.6 V
-
-
0.1
A
IOFF
power-off leakage current
VI or VO = 0 V to 3.6 V; VCC = 0 V
-
-
0.2
A
IOFF
additional power-off
leakage current
VI or VO = 0 V to 3.6 V;
VCC = 0 V to 0.2 V
-
-
0.2
A
ICC
supply current
VI = GND or VCC; IO = 0 A;
VCC = 0.8 V to 3.6 V
-
-
0.5
A
ICC
additional supply current
VI = VCC 0.6 V; IO = 0 A;
VCC = 3.3 V
-
-
40
A
CI
input capacitance
VCC = 0 V to 3.6 V; VI = GND or VCC
-
0.8
-
pF
CO
output capacitance
VO = GND; VCC = 0 V
-
1.7
-
pF
74AUP1G16
Product data sheet
[1]
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 7 October 2016
©
Nexperia B.V. 2017. All rights reserved
5 of 17
74AUP1G16
Nexperia
Low-power buffer
Table 7.
Static characteristics …continued
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
Typ
Max
Unit
VCC = 0.8 V
0.70 VCC
-
-
V
VCC = 0.9 V to 1.95 V
0.65 VCC
-
-
V
VCC = 2.3 V to 2.7 V
1.6
-
-
V
VCC = 3.0 V to 3.6 V
2.0
-
-
V
-
-
0.30 VCC V
0.35 VCC V
Tamb = 40 C to +85 C
VIH
VIL
VOH
VOL
HIGH-level input voltage
LOW-level input voltage
HIGH-level output voltage
LOW-level output voltage
VCC = 0.8 V
VCC = 0.9 V to 1.95 V
-
-
VCC = 2.3 V to 2.7 V
-
-
0.7
V
VCC = 3.0 V to 3.6 V
-
-
0.9
V
VI = VIH or VIL
IO = 20 A; VCC = 0.8 V to 3.6 V
VCC 0.1
-
-
V
IO = 1.1 mA; VCC = 1.1 V
0.7 VCC
-
-
V
IO = 1.7 mA; VCC = 1.4 V
1.03
-
-
V
IO = 1.9 mA; VCC = 1.65 V
1.30
-
-
V
IO = 2.3 mA; VCC = 2.3 V
1.97
-
-
V
IO = 3.1 mA; VCC = 2.3 V
1.85
-
-
V
IO = 2.7 mA; VCC = 3.0 V
2.67
-
-
V
IO = 4.0 mA; VCC = 3.0 V
2.55
-
-
V
IO = 20 A; VCC = 0.8 V to 3.6 V
-
-
0.1
V
IO = 1.1 mA; VCC = 1.1 V
-
-
IO = 1.7 mA; VCC = 1.4 V
-
-
VI = VIH or VIL
0.3 VCC V
0.37
V
IO = 1.9 mA; VCC = 1.65 V
-
-
0.35
V
IO = 2.3 mA; VCC = 2.3 V
-
-
0.33
V
IO = 3.1 mA; VCC = 2.3 V
-
-
0.45
V
IO = 2.7 mA; VCC = 3.0 V
-
-
0.33
V
IO = 4.0 mA; VCC = 3.0 V
-
-
0.45
V
II
input leakage current
VI = GND to 3.6 V; VCC = 0 V to 3.6 V
-
-
0.5
A
IOFF
power-off leakage current
VI or VO = 0 V to 3.6 V; VCC = 0 V
-
-
0.5
A
IOFF
additional power-off
leakage current
VI or VO = 0 V to 3.6 V;
VCC = 0 V to 0.2 V
-
-
0.6
A
ICC
supply current
VI = GND or VCC; IO = 0 A;
VCC = 0.8 V to 3.6 V
-
-
0.9
A
ICC
additional supply current
VI = VCC 0.6 V; IO = 0 A;
VCC = 3.3 V
-
-
50
A
74AUP1G16
Product data sheet
[1]
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 7 October 2016
©
Nexperia B.V. 2017. All rights reserved
6 of 17
74AUP1G16
Nexperia
Low-power buffer
Table 7.
Static characteristics …continued
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
Typ
Max
Unit
VCC = 0.8 V
0.75 VCC
-
-
V
VCC = 0.9 V to 1.95 V
0.70 VCC
-
-
V
VCC = 2.3 V to 2.7 V
1.6
-
-
V
VCC = 3.0 V to 3.6 V
2.0
-
-
V
-
-
0.25 VCC V
0.30 VCC V
Tamb = 40 C to +125 C
HIGH-level input voltage
VIH
LOW-level input voltage
VIL
VOH
HIGH-level output voltage
LOW-level output voltage
VOL
VCC = 0.8 V
VCC = 0.9 V to 1.95 V
-
-
VCC = 2.3 V to 2.7 V
-
-
0.7
V
VCC = 3.0 V to 3.6 V
-
-
0.9
V
VI = VIH or VIL
IO = 20 A; VCC = 0.8 V to 3.6 V
VCC 0.11
-
-
V
IO = 1.1 mA; VCC = 1.1 V
0.6 VCC
-
-
V
IO = 1.7 mA; VCC = 1.4 V
0.93
-
-
V
IO = 1.9 mA; VCC = 1.65 V
1.17
-
-
V
IO = 2.3 mA; VCC = 2.3 V
1.77
-
-
V
IO = 3.1 mA; VCC = 2.3 V
1.67
-
-
V
IO = 2.7 mA; VCC = 3.0 V
2.40
-
-
V
IO = 4.0 mA; VCC = 3.0 V
2.30
-
-
V
IO = 20 A; VCC = 0.8 V to 3.6 V
-
-
0.11
V
IO = 1.1 mA; VCC = 1.1 V
-
-
IO = 1.7 mA; VCC = 1.4 V
-
-
VI = VIH or VIL
0.33 VCC V
0.41
V
IO = 1.9 mA; VCC = 1.65 V
-
-
0.39
V
IO = 2.3 mA; VCC = 2.3 V
-
-
0.36
V
IO = 3.1 mA; VCC = 2.3 V
-
-
0.50
V
IO = 2.7 mA; VCC = 3.0 V
-
-
0.36
V
IO = 4.0 mA; VCC = 3.0 V
-
-
0.50
V
II
input leakage current
VI = GND to 3.6 V; VCC = 0 V to 3.6 V
-
-
0.75
A
IOFF
power-off leakage current
VI or VO = 0 V to 3.6 V; VCC = 0 V
-
-
0.75
A
IOFF
additional power-off
leakage current
VI or VO = 0 V to 3.6 V;
VCC = 0 V to 0.2 V
-
-
0.75
A
ICC
supply current
VI = GND or VCC; IO = 0 A;
VCC = 0.8 V to 3.6 V
-
-
1.4
A
ICC
additional supply current
VI = VCC 0.6 V; IO = 0 A;
VCC = 3.3 V
-
-
75
A
[1]
[1]
One input at VCC 0.6 V, other input at VCC or GND.
74AUP1G16
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 7 October 2016
©
Nexperia B.V. 2017. All rights reserved
7 of 17
74AUP1G16
Nexperia
Low-power buffer
11. Dynamic characteristics
Table 8.
Dynamic characteristics
Voltages are referenced to GND (ground = 0 V); for test circuit see Figure 7.
Symbol Parameter
Tamb = 25 C
Conditions
Tamb = 40 C to +125 C
Unit
Min
Typ[1]
Max
Min
Max
(85 C)
Min
Max
(125 C)
-
15.0
-
-
-
-
-
VCC = 1.1 V to 1.3 V
2.6
4.7
9.2
2.0
10.0
2.0
11.0
ns
VCC = 1.4 V to 1.6 V
2.1
3.4
5.7
1.6
6.5
1.6
7.2
ns
VCC = 1.65 V to 1.95 V
1.8
2.9
4.5
1.4
5.2
1.4
5.8
ns
VCC = 2.3 V to 2.7 V
1.5
2.3
3.5
1.2
4.2
1.2
4.6
ns
VCC = 3.0 V to 3.6 V
1.4
2.1
3.2
1.0
3.8
1.0
4.2
ns
-
18.4
-
-
-
-
-
ns
VCC = 1.1 V to 1.3 V
3.2
5.6
10.9
2.3
11.8
2.3
13.1
ns
VCC = 1.4 V to 1.6 V
2.6
4.1
6.7
1.9
7.7
1.9
8.5
ns
VCC = 1.65 V to 1.95 V
2.3
3.4
5.3
1.7
6.2
1.7
6.9
ns
VCC = 2.3 V to 2.7 V
2.0
2.9
4.2
1.5
5.0
1.5
5.5
ns
VCC = 3.0 V to 3.6 V
1.7
2.6
3.8
1.4
4.6
1.4
5.1
ns
-
21.9
-
-
-
-
-
ns
VCC = 1.1 V to 1.3 V
3.6
6.4
12.6
2.6
13.8
2.6
15.2
ns
VCC = 1.4 V to 1.6 V
3.0
4.6
7.6
2.2
8.9
2.2
9.8
ns
VCC = 1.65 V to 1.95 V
2.6
3.9
6.0
2.0
7.2
2.0
7.9
ns
VCC = 2.3 V to 2.7 V
2.3
3.3
4.8
1.8
5.7
1.8
6.3
ns
VCC = 3.0 V to 3.6 V
2.1
3.1
4.2
1.6
5.0
1.6
5.5
ns
-
32.1
-
-
-
-
-
ns
VCC = 1.1 V to 1.3 V
4.8
8.7
16.3
3.6
18.9
3.6
20.8
ns
VCC = 1.4 V to 1.6 V
4.0
6.2
10.3
3.4
12.2
3.4
13.4
ns
VCC = 1.65 V to 1.95 V
3.6
5.2
8.1
3.2
9.8
3.2
10.8
ns
VCC = 2.3 V to 2.7 V
3.0
4.4
6.4
2.7
7.7
2.7
8.5
ns
VCC = 3.0 V to 3.6 V
2.9
4.2
5.6
2.5
6.5
2.5
7.2
ns
CL = 5 pF
tpd
propagation
delay
[2]
A to Y; see Figure 6
VCC = 0.8 V
ns
CL = 10 pF
tpd
propagation
delay
[2]
A to Y; see Figure 6
VCC = 0.8 V
CL = 15 pF
tpd
propagation
delay
[2]
A to Y; see Figure 6
VCC = 0.8 V
CL = 30 pF
tpd
propagation
delay
74AUP1G16
Product data sheet
[2]
A to Y; see Figure 6
VCC = 0.8 V
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 7 October 2016
©
Nexperia B.V. 2017. All rights reserved
8 of 17
74AUP1G16
Nexperia
Low-power buffer
Table 8.
Dynamic characteristics …continued
Voltages are referenced to GND (ground = 0 V); for test circuit see Figure 7.
Symbol Parameter
CPD
Tamb = 25 C
Conditions
power
dissipation
capacitance
Unit
Min
Max
Min
Max
(85 C)
Min
Max
(125 C)
VCC = 0.8 V
-
2.5
-
-
-
-
-
pF
VCC = 1.1 V to 1.3 V
-
2.6
-
-
-
-
-
pF
[3]
fi = 1 MHz;
VI = GND to VCC
VCC = 1.4 V to 1.6 V
-
2.7
-
-
-
-
-
pF
VCC = 1.65 V to 1.95 V
-
2.9
-
-
-
-
-
pF
VCC = 2.3 V to 2.7 V
-
3.4
-
-
-
-
-
pF
VCC = 3.0 V to 3.6 V
-
4.0
-
-
-
-
-
pF
[1]
All typical values are measured at nominal VCC.
[2]
tpd is the same as tPLH and tPHL.
[3]
Tamb = 40 C to +125 C
Typ[1]
CPD is used to determine the dynamic power dissipation (PD in W).
PD = CPD VCC2 fi N + (CL VCC2 fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in V;
N = number of inputs switching;
(CL VCC2 fo) = sum of outputs.
12. Waveforms
9,
90
$LQSXW
*1'
W 3+/
W 3/+
92+
90