0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CR5310-75

CR5310-75

  • 厂商:

    CR

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
CR5310-75 数据手册
DC Voltage Transducer DIN RAIL / PANEL MOUNT, RMS The CR5300 Series, DC Voltage Transducers and Transmitters, are designed to provide an output DC signal that is proportional to the input DC voltage. These devices are especially suited for applications with a current shunt to monitor DC current. Applications Power Supply over/under sensing Battery chargers and systems Mobile applications Power sensing CR5310 Features CR5320 Output isolated from input Available with 0-5 VDC, 0-10 VDC or 4 - 20 mADC outputs 35mm DIN rail or panel mount Connection diagram printed on case Single Element 0.1 - 600 VDC Input Range C Transducers CR5311 Regulatory Agencies If you need a relay output, use a CR3395. See Section for Details. Recognized to meet UL 61010B-1 Constructed to meet CAN/CSA-C22.2, No. 61010-1-2004 Meets requirement of IEC 61010-1 and BS EN 61010-1 CR5310 with Resistor Application is shown below (optional). L1 E199795 L2 1 2 3 4 9 8 7 6 5 M XXXX + - Add suffix for input range PART NUMBERS CR5310 CR5311 CR5320 - Single Element with ± 5 VDC output Single Element with ± 10 VDC output Single Element with 4 - 20 mADC output NOTE: CR5300 Series is available with 12V Power Supply. Use same application as 24V Power Supply. Example Part Number: CR5310-300-12V The Professional Energy Monitoring Company M N TI ISO 9001:2008 Quality Management System 1 5 10 50 150 200 - 0-1 VDC 0-5 VDC 0-10 VDC 0-50 VDC 0-150 VDC 0-200 VDC Ranges available up to and including 1,000 VDC * UL Recognized up to 300 Vdc 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com 48 E-mail: sales@crmagnetics.com DC Voltage Transducer DIN RAIL / PANEL MOUNT, RMS SPECIFICATIONS Basic Accuracy:....................... 1.0 % Linearity:................................... 10% to 100% FS Thermal Drift:........................... 500 PPM/°C Operating Temperature:........... 0°C to +50°C Installation Category:............... CAT II Isolation Voltage:....................... 2500KVRMS/1mA/1Sec Vibration Tested To:................. IEC 60068-2-6,1995 Pollution Degree:..................... 2 Altitude:................................... 2000 meter max. Response Time: .................... 250 ms. max. Insulation Voltage:................... 2500 VDC Cleaning:................................. Water-dampened cloth Supply Voltage:............. 24 VDC ±10% Frequency Range:........ DC only Output Load:.................. 4-20 mADC - 0 to 300 Ω 0-5 VDC - 2K Ω or Greater Relative Humidity:........ 5% to 95%, Non-Condensing Supply Current: CR5310:........................ Typical 35mA Max 40mA CR5320:........................ Typical 35mA Max 40mA Torque Specs.:.............. 3.0 inch lbs. (0.4Nm) Weight:.......................... 0.5 lbs. C Top View [3.3] .13 Optional Mounting DIN RAIL MOUNTING CLIP [73.1] 2.88 [83.3] 3.28 + INPUT 1 - 1 2 3 4 + 9 8 7 6 5 OUTPUT 1 - + SUPPLY CR5310 5 VDC Output CR5311 10 VDC Output [62.1] 2.45 [5.6] .22 TYP [88.7] 3.49 + CR5310 CR5311 CR5320 INPUT 1 - 1 2 3 4 + 9 8 7 6 5 OUTPUT 1 + - - SUPPLY [30.4] 1.20 CR5320 4 - 20 mADC Output [28.3] 1.12 End View [36.6] 1.44 OUTLINE DRAWING CONNECTION DIAGRAM NOTE: The building installation must have a switch or circuit-breaker that is in close proximity and within easy reach of the operator. The switch or circuit breaker shall be marked as the disconnecting device for the equipment. The Professional Energy Monitoring Company M N TI ISO 9001:2008 Quality Management System 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com 49 E-mail: sales@crmagnetics.com Transducers [26.6] 1.05
CR5310-75 价格&库存

很抱歉,暂时无法提供与“CR5310-75”相匹配的价格&库存,您可以联系我们找货

免费人工找货