0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CRD4570-150

CRD4570-150

  • 厂商:

    CR

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
CRD4570-150 数据手册
Data Stream RS485 Digital Voltage Transducer DIN RAIL / PANEL MOUNT The CRD4500 Series Data Stream Digital Transducers are designed for applications where AC current waveforms are not purely sinusoidal. The digital technology is used to measure voltage, current, power frequency and energy in single and three phase designs. The data is streamed over an RS485 IEEE bus which enables multiple transducers to communicate thru a single master connection. These advanced sensors are ideal for entire plant or zone monitoring. Also, the communication alagorithm can be pre-ordered with ASCII based control or modified MODBUS based control. Sensing True RMS Voltage, Each Phase CRD4510 Single Element 150 to 300 VAC Input Range Applications Features 35mm DIN Rail or Panel Mount Red LED - Flashes when Power is Connected Red & Green LED Flash during Communication 24 VDC powered Use with external current transformers Highest precision available Connection diagram printed on case CRD4550 Two Element 150 to 300 VAC Input Range Regulatory Agencies CRD4570 Three Element 150 to 300 VAC Input Range PART NUMBERS CRD4510 CRD4550 CRD4570 - Single Element, AC Voltage RS485 Digital Transducer Two Element, AC Voltage RS485 Digital Transducer Three Element, AC RS485 Digital Transducer 150 300 - 0-150 VAC 0-300 VAC Available up to and including 600 VAC The Professional Energy Monitoring Company M N TI ISO 9001:2008 Quality Management System Note: Add an M at the end for MODBUS CRD4510-150-M 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com 17 E-mail: sales@crmagnetics.com Data Stream Sub-Metering Motor Loads Uninterruptible Power Systems Remote Monitoring Load Shedding Energy Management B RS485 Digital Voltage Transducer SPECIFICATIONS B Basic Accuracy: .......................0.5% Calibration: ..............................True RMS Sensing Thermal Drift: ..........................500 PPM/°C Operating Temperature1: ..........0°C to +60°C Installation Category: ..............CAT II Vibration Tested To: .................IEC 60068-2-6,1995 Pollution Degree: ....................2 Insulation Voltage: ..................2500 VDC Altitude: ..................................2000 meter max Frequency Range: .................20 Hz - 5 KHz MTBF: ....................................Greater than 100K hours Cleaning: ................................Water-dampened cloth Supply Voltage2: ......................24 VDC ±10% Torque Specifications: ....................3.0 inch lbs (0.4Nm) Response Time: .......................250 ms. max. 0-90% FS Relative Humidity: .............5% to 95%, Non-Condensing Output Resolution: ..................................................16 bit Transducer fanout on common bus: ...................64 max. Baud Rate3: ...............1200, 2400, 4800, 9600,19.2K .bps A/D Conversion Type: ..................4th order Delta Sigma Device Address3: ............................................00 to FF Data Format: .... .....................................................ASCII Supply Current:..................Typical 30mA Max 30mA Weight:.. ..............................................................0.5 lbs. 1) RH 5% to 95%, non-condensing 2) 0.4% max. ripple Vpp no flow control, 1 stop bit Data Stream 3) Factory default settings: address 01, baud rate 9600, no parity, L2 N L1 N L1 L2 LINEN L1 1 2 3 4 9 8 7 6 5 1 2 3 4 + 485 - - + L3 L2 L2 L1 L3 L1 1 2 3 4 + 485 485 - + SUPPLY SUPPLY LOAD LOAD SUPPLY SUPPLY LOAD LOAD + 485 485 - 9 8 7 6 5 - + - + N N L3 L2 L2 L1 L1 L3 9 8 7 6 5 - CRD4550 Dual Element, 3-Wire CRD4510 Single Element, 2-Wire 1 2 3 4 + 485 485 SUPPLY SUPPLY LOAD LOAD SUPPLY LOAD 9 8 7 6 5 CRD4570 3 Element, 4-Wire CRD4550 Dual Element, 3-Wire Connection Diagram CRD485-232 RS485 to RS232 Converter Accessory Connect PC to RS485 Bus RED INDICATIOR LED GREEN INDICATOR LED RX [26.6] 1.05 [3.3] .13 OPTIONAL MOUNTING 1 2 3 4 DATA STREAM TRANSDUCER DIN RAIL MOUNTING CLIP [73.1] 2.88 [83.3] 3.28 TX DATA + 9 8 7 6 5 DATAGND CRD485-232 +5VDC + - COM RS232 GND DB 9, FEMALE SUPPLY [25] .98 ASCII Simplified Programming Commands [78.7] 3.10 MAX [76.7] 3.02 [5.6] .22 TYP [28.3] 1.12 [88.7] 3.49 [36.6] 1.44 OUTLINE DRAWING The Professional Energy Monitoring Company M N TI ISO 9001:2008 Quality Management System A simplified data structure is used with only 6 commands required for full control of the transducer. Commands are : Read Transducer Name, Read Configuration, Set Configuration, Read Measurements, Read Energy Totalizer and Clear Energy Totalizer. For illustration, the following commands are used to read data from a CRD5170 3 Phase, 4 Wire Transducer with a device address of 00. Command Transducer to Read Data: #00A Transducers Response: >+[% FS VoltageL1-N]+[% FS CurrentL1]+[% FS VoltageL2-N]+[% FS CurrentL2]+[% FS VoltageL3-N]+[% FS CurrentL3,][+/- % FS Power][+/-% FS VARS][+/-Power Factor][Frequency] Command Transducer to Read Energy Totalizer: #00W Transducer Responds: 01[+/-KWHr]{\[+/-KVHr][check sum] Note: This is for illustration purposes only, See Applications Guides (Section I for complete instructions. 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com 18 E-mail: sales@crmagnetics.com
CRD4570-150 价格&库存

很抱歉,暂时无法提供与“CRD4570-150”相匹配的价格&库存,您可以联系我们找货

免费人工找货