0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CR5211-5

CR5211-5

  • 厂商:

    CR

  • 封装:

    Module

  • 描述:

  • 数据手册
  • 价格&库存
CR5211-5 数据手册
DC Current Transducer DIN RAIL / PANEL MOUNT, RMS The CR5200 Series, DC Current Transducers are designed to provide a DC signal which is proportional to a DC sensed current. These devices are designed for direct current only, targeting them towards general and daily applications. The ranges 2 to 10 Amp utilize an advanced Magnetic Modulator technology and the ranges 20 amps and above utilize Hall Effect technology. Applications CR5210 Transducers C CR5211 Battery chargers and systems DC motor drives Power supply management Mobile applications CR5220 Features Single Element - .79” Window 0.1 to 600 ADC Input Range Closed loop sensing for accuracy 35mm DIN rail or panel mount Available with ±5 VDC, ±10 VDC or 4 - 20 mADC outputs Non-contact DC current sensing Connection diagram printed on case Regulatory Agencies Constructed to meet UL 61010B-1 Constructed to meet CAN/CSA-C22.2, No. 61010-1-2004 Meets requirement of IEC 61010-1 and BS EN 61010-1 CR5210S CR5211S CR5220S Single Element - 1.2” Window 20 to 600 ADC Input Range E199795 Contact Factory for Custom ±5 VDC, ±10 VDC or 4 - 20 mADC Output Options All single phase current transducers are available in split core design. Simply put an “S” at the end of the prefix* I.E. CR5210S-30 Add suffix for input range PART NUMBERS CR5210(S) CR5211(S) CR5220(S) - Single Element with ± 5 VDC output (split core design) Single Element with ± 10 VDC output (split core design) Single Element with 4 - 20 mADC output (split core design) NOTE: DC Split Core Transducers Available in 20 Amps and Higher NOTE: CR5200 Series is available with 12V Power Supply. Use same application as 24V Power Supply. Example Part Number: CR5210-300-12V The Professional Energy Monitoring Company M N TI ISO 9001:2008 Quality Management System 2 5 10 20 30 50 75 100 150 300 - 0-2 ADC 0-5 ADC 0-10 ADC 0-20 ADC 0-30 ADC 0-50 ADC 0-75 ADC 0-100 ADC 0-150 ADC 0-300 ADC Ranges available up to and including 600 ADC 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com 46 E-mail: sales@crmagnetics.com DC Current Transducer DIN RAIL / PANEL MOUNT, RMS SPECIFICATIONS Basic Accuracy:........................ 1.0 % Linearity:................................... 10% to 100% FS Thermal Drift:............................ 500 PPM/°C Operating Temperature:............ 0°C to +50°C Installation Category:................ CAT II Isolation Voltage:....................... 3500KVRMS/1mA/1Sec Vibration Tested To:................... IEC 60068-2-6,1995 Pollution Degree:..................... 2 Response Time: ..................... 250 ms Altitude:................................... 2000 meter max. Insulation Voltage:................... 2500 VDC Supply Voltage:....................... 24 VDC ±10% Frequency Range:.................. DC Only Cleaning:................................ Water-dampened cloth MTBF:......................... Greater than 100 K hours Output Load:............... 4-20 mADC - 0 to 300 Ω 0-5 VDC - 2K Ω or Greater Relative Humidity:..... 5% to 95%, Non-Condensing Supply Current: CR5210:.................... Typical 35mA Max 40mA CR5210S:.................. Typical 30mA Max 35mA CR5220:.................... Typical 60mA Max 100mA CR5220S:.................. Typical 40mA Max 50mA Torque Specs.:........... 3.0 inch lbs. (0.4Nm) Weight:....................... 0.5 lbs. C [3.3] .13 Optional Mounting 1 2 3 4 DIN RAIL MOUNTING CLIP [73.1] 2.88 [83.3] 3.28 CR5210 CR5211 [76.6] 3.02 OUTPUT + SUPPLY 5 VDC Output 10 VDC Output + [50.7] 2.00 [5.6] .22 TYP + 9 8 7 6 5 - [20.1] .79 [41.8] 1.65 Transducers + [26.6] 1.05 + 1 2 3 4 9 8 7 6 5 [88.7] 3.49 OUTPUT + SUPPLY - [25] .98 CR5220 4 - 20 mADC Output [28.3] 1.12 [36.6] 1.44 CONNECTION DIAGRAM OUTLINE DRAWING NOTE: The building installation must have a switch or circuit-breaker that is in close proximity and within easy reach of the operator. The switch or circuit breaker shall be marked as the disconnecting device for the equipment. The Professional Energy Monitoring Company M N TI ISO 9001:2008 Quality Management System 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com 47 E-mail: sales@crmagnetics.com
CR5211-5 价格&库存

很抱歉,暂时无法提供与“CR5211-5”相匹配的价格&库存,您可以联系我们找货

免费人工找货