Customer Specification
PART NO: AW0400105
M12-A Female 90 Degree
Drawings
Issue: 1 Issue Date: 7/29/2016 Effective Date: 7/29/2016
Technical Data
Cordage Construction
Cordage Part Number
Component 1
a) Conductor
b) Insulation
Insulation Colors
Jacket
a) Color(s)
Cord Configuration
End 1
End 2
Insert
Mold Color
Contact
Coupling Nut
O-Ring
Available Lengths
Applicable SpecificationsCable
UL
Diameters (In)
105
4 COND
22 (26/36) AWG Bare Copper
0.011” Wall, Nom. SR-PVC
Black, White, Brown & Blue
0.032” Wall, Nom. PVC
SLATE
0.027
0.049
0.189
M12-A Female, 90 Degree
Cut End
Black TPU
Black TPU
Copper Alloy, Gold plated
Copper Alloy, Nickel plated
FKM
0.6, 1, 3, 5, 10, 15, 20 Meters
AWM/STYLE 2661
•••••••••••••••••••••••••••••••••••••••
Alpha Wire | 711 Lidgerwood Ave, Elizabeth, NJ 07207
www.alphawire.com | 1-800-52 ALPHA
105°C / 300 V RMS
1
Customer Specification
PART NO: AW0400105
M12-A Female 90 Degree
CSA International
Applicable SpecificationsCord Set
UL
CSA
Nominal Voltage
Rated Voltage
Ingress Protection
Environmental Compliance
CE
REACH Regulation (EC
1907/2006)
Physical & Mechanical
Properties
Temperature Range, Cord
Temperature Range,
Connector
Bend Radius
Pull Tension
Current Rating
Ordering Information
AW0400105 SL355
AW0400105 SL356
AW0400105 SL357
AW0400105 SL358
AW0400105 SL359
AW0400105 SL400
AW0400105 SL401
Standard Package
C(RU) AWM I/II A/B FT1
105°C / 300 V RMS
ANSI/UL 2238, Cable Assembly Extension
RU, UL File Number E485156
CSA-C22.2 No. 182.3, Special Use
Attachment Plugs, Receptacles and
Connectors
cRU, UL File Number E485156
240 V
250 V
IP67/NEMA 6P
All materials used in the manufacture of
this part meet the requirements of
European Directive 2011/65/EU regarding
the restriction of use of certain hazardous
substances in electrical and electronic
equipment. Exemption used; 6a.
This product does not contain Substances
of Very High Concern (SVHC) listed on the
European Union’s REACH candidate list in
excess of 0.1% mass of the item.
-40 to 105°C(static), -15 to 105°C (dynamic)
-25°C to +80°C
7X Cable Diameter (static), 10X Cable
Diameter (dynamic)
20.4 Lbs, Maximum
2.5 Amps @ 50°C
0.6 Meters
1.0 Meters
3.0 Meters
5.0 Meters
10.0 Meters
15.0 Meters
20.0 Meters
Each
Although Alpha Wire (“Alpha”) makes every reasonable effort to ensure their accuracy at the time of this publication, information and
specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
• •product
• • • • •availability.
• • • • • • Alpha
• • • •provides
• • • • • the
• • •information
• • • • • • •and
• • specification
•••••
specifications does not ensure
herein on an “AS IS” basis, with no
Alpha
Wire
| 711
Lidgerwood
Ave,
NJ 07207
representations or warranties,
whether
express,
statutory
or implied.
In noElizabeth,
event will Alpha
be liable any damages (including consequential,
2
www.alphawire.com
| 1-800-52
indirect, incidental, special, punitive, or exemplary
damages) whatsoever,
even if ALPHA
Alpha has been advised of the possibility of such damages,
whether in an action under contact, negligence or any other theory, arising out of or in connection with the use, or inability to use, the
information or specification described herein.
很抱歉,暂时无法提供与“AW0400105SL355”相匹配的价格&库存,您可以联系我们找货