16582-2

16582-2

  • 厂商:

    EATON(伊顿)

  • 封装:

    -

  • 描述:

    接线端子

  • 数据手册
  • 价格&库存
16582-2 数据手册
Technical Data 10534 Effective January 2019 Supersedes September 2017 Splicer blocks Catalog number example: 16204-3 is a 3-pole 16204 Where: • The prefix “16204” defines the block’s lineside and loadside characteristics (i.e., conductor port per pole that accepts 2/0 - #14 Cu, or 2/0 - #12 Al conductors). • The suffix “3” in this example defines this as a three-pole block. • See the catalog number tables for details on the available lineside/loadside characteristics. How to order: From the catalog number tables, select the catalog number that defines the desired lineside/loadside port and conductor characteristics. Catalog symbols: Add to the catalog number the suffix that defines the desired pole configuration. Note, you must select from the available number of poles for each catalog number. These appear in the second column of the catalog number tables. • 160__-(poles) • 162__-(poles) Specifications: • 163__-(poles) Ratings • 165__-(poles) • Volts: 600 V • Amps: 115 to 760 A • SCCR: up to 200 kA* (see table for SCCR by catalog number) Description: Bussmann™ series splicer blocks allow for increasing or decreasing wire size within a circuit to accommodate different connections from the power source to the branch load. Splicer blocks are available for wire sizes up to 500 kcmil and amp ratings up to 760 A. They are UL® Recognized to UL 1059 and rated for use in UL 508A industrial control panels. These blocks are factory configured from 1- to 4-poles (catalog number dependent) with optional covers (order covers separately). * Maximum SCCR contingent upon the application of an upstream current-limiting overcurrent protective device. See table for fusing requirements. Flammability rating • UL 94 V0 Storage and operating temperature range • -4°F to 248°F (-20°C to 120°C) Agency information • UL 1059 Recognized, Guide XCFR2, File E62622 • CSA® Certified, Class 6228-01, File 15364 Conductors† • Stranded 75°C copper and aluminum • Higher temperature rated conductors permitted with appropriate derating † As specified in the catalog number table. Optional covers • See table for catalog numbers specific to each block Technical Data 10534 Splicer blocks Effective January 2019 Catalog numbers: Lineside Line/load port configuration No. of poles 1, 2, 3 1, 2, 3 2, 3, 4 1, 2, 3 Current rating (A) Loadside Wire size (Str/ferrule unless noted)* Wires per port Torque N•m (Lb-in) #2 - #3 Cu/Al (Str) 1 #4 - #6 Cu/Al (Str) 1 #8 Cu/Al (Str) 1 4.5 (40) #10 - #14 Cu (Str) 1 1/0 - #3 Cu (Str) 1 #4 - #6 Cu (Str) 115 150 175 175 Wire size (Str/ferrule unless noted)* Wires per port Torque N•m (Lb-in) 5.6 (50) #2 - #3 Cu/Al (Str) 1 5.6 (50) 5.1 (45) #4 - #6 Cu/Al (Str) 1 5.1 (45) #8 Cu/Al (Str) 1 4.5 (40) 4.0 (35) #10 - #14 Cu (Str) 1 4.0 (35) 5.6 (50) 1/0 - #3 Cu (Str) 1 5.6 (50) 1 5.1 (45) #4 - #6 Cu (Str) 1 5.1 (45) #8 Cu (Str) 1 4.5 (40) #8 Cu (Str) 1 4.5 (40) 4.0 (35) 4.0 (35) #10 - #14 Cu (Str) 1 2/0 - #1 Cu/Al (Str) 1 #2 - #8 Cu/Al 1 #10 - #12 Al (Str) 1 #10 - #14 Cu 1 #4 - #8 Cu/Al 2 #10 - #14 Cu 2 2/0 - #1 Cu/Al (Str) 1 #2 - #8 Cu/Al 1 #10 - #12 Al (Str) 1 #10 - #14 Cu 1 #4 - #8 Cu/Al 2 #10 - #14 Cu 2 Ports/ Pole 1 1 12.4 (110) 4.0 (35) 1 13.6 (120) 12.4 (110) 4.0 (35) 1 13.6 (120) #10 - #14 Cu (Str) 1 2/0 - #1 Cu/Al (Str) 1 #2 - #8 Cu/Al 1 #10 - #12 Al (Str) 1 #10 - #14 Cu 1 #4 - #8 Cu/Al 2 #10 - #14 Cu 2 2/0 - #1 Cu/Al (Str) 1 #2 - #8 Cu/Al 1 #10 - #12 Al (Str) 1 #10 - #14 Cu 1 #4 - #8 Cu/Al 2 #10 - #14 Cu 2 Ports/ pole SCCR (kA) Catalog number 1 10 16200-_** 1 10 16201-_ 1 10 16000-_** 1 200† 12.4 (110) 4.0 (35) 13.6 (120) 12.4 (110) 4.0 (35) 16204-_ 13.6 (120) 2, 3, 4 255 250 kcmil - #6 Cu 1 42.4 (375) 1 250 kcmil - #6 Cu 1 42.4 (375) 1 10 16003-_** 1, 2, ,3 255 250 kcmil - #6 Cu 1 42.4 (375) 1 250 kcmil - #6 Cu 1 42.4 (375) 1 10 16301-_ 2, 3, 4 310 31.1 (275)†† 1 31.1 (275)†† 1 10 16005-_** 31.1 (275)†† 1 10 16303-_ 56.5 (500) 1 10 16306-_ 31.1 (275)†† 2 10 16500-_ 56.5 (500) 2 10 16504-_ 1, 2, ,3 1, 2, ,3 1, 2, ,3 1, 2, ,3 350 kcmil - 2/0 Cu/Al (Str) 1 1/0 Cu/Al (Str) 1-2 #1 - #6 Cu/Al 1-2 350 kcmil - 2/0 Cu/Al (Str) 1 1/0 Cu/Al (Str) 1-2 #1 - #6 Cu/Al 350 kcmil - 2/0 Cu/Al (Str) 1 1/0 Cu/Al (Str) 1-2 #1 - #6 Cu/Al 1-2 350 kcmil - 2/0 Cu/Al (Str) 1 1/0 Cu/Al (Str) 1-2 1-2 #1 - #6 Cu/Al 1-2 500 kcmil - 4/0 Cu/Al (Str) 1 500 kcmil - 4/0 Cu/Al (Str) 1 3/0 - 1/0 Cu/Al (Str) 1-2 3/0 - 1/0 Cu/Al (Str) 1-2 #1 - #6 Cu/Al 1-2 #1 - #6 Cu/Al 1-2 310 380 350 kcmil - 2/0 Cu/Al (Str) 1 1/0 Cu/Al (Str) 1-2 #1 - #4 Cu/Al 1-2 #6 Cu/Al 2 620 500 kcmil - 4/0 Cu/Al (Str) 1 3/0 - 1/0 Cu/Al (Str) 1-2 #1 - #6 Cu/Al 1-2 760 31.1 (275)†† 56.5 (500) 31.1 (275) †† 56.5 (500) 1 1 2 2 350 kcmil - 2/0 Cu/Al (Str) 1 1/0 Cu/Al (Str) 1-2 #1 - #4 Cu/Al 1-2 #6 Cu/Al 2 500 kcmil - 4/0 Cu/Al (Str) 1 3/0 - 1/0 Cu/Al (Str) 1-2 #1 - #6 Cu/Al 1-2 * 75°C wire (higher temperature rated wire acceptable with appropriate derating). Using a ferrule on a stranded conductor requires a correctly sized UL Listed ferrule (customer supplied) applied according to the manufacturer’s specifications. Ferrule ratings apply to copper wire only. ** Not covered by CSA certification. † See table below for the tested upstream overcurrent protective devices necessary for achieving this SCCR. †† Torque rating for dual wire and ferrule application is 30.5 N•m (270 Lb-in). Short-Circuit Current Rating (SCCR) data for block 16204-_: Conductors (AWG) Catalog number 16204-_ 2 No. of poles 1, 2, 3 Lineside 2/0 - #8 Eaton.com/bussmannseries Loadside 2/0 - #8 Fuse class/Bussmann series symbol/ampacity RK1 RK5 T J LPN-RK (250 V), FRN-R (250 V), JJN (300 V), LPJ LPS-RK (600 V) FRS-R (600 V) JJS (600 V) SCCR 200 200 60 200 200 kA Min. enclosure size 16 x 16 x 6.75 Technical Data 10534 Splicer blocks Effective January 2019 Ferrule terminal application Dual wire port application • • Rated for dual wire port application to increase the possible number of lineside and loadside connections. E.g., 16303-1 can accept two wires into the lineside port (1/0 - #6 Cu/Al) and two wires per port (2 connections per pole total) on the loadside lug (1/0 - #6 Cu/Al). Dual wire applications are only viable when using two wires of the same size, stranding, and insulating and conductor material in the same port. • Bussmann series splicer blocks are rated for use with UL Listed ferrules (see catalog number table for details). Ferrule ratings apply to copper wire only. • Ferrule applications allow for the use of a broader range of conductor stranding and simulate a more efficient, solid wire connection with the PDB terminal port. • Always use UL Listed ferrules in accordance with the manufacturer’s specifications and instructions. Dimensions — in 160_ blocks 4.12" (2-Pole) 5.37" (3-Pole) 6.62" (4-Pole) 0.69" 3.62" (2-Pole) 4.87" (3-Pole) 6.12" (4-Pole) 0.25" 0.50" Lineside 2.75" 2.12" 1.00" 2.00" 1.38" 0.27" Dia. (2 holes) Loadside 0.38" Slot 0.22" x 0.38" (4 places) 162_, 163_ and 165_ blocks C F E D E J H Lineside A B L C'Bore G Catalog number prefix 162_ 163_ 165_ K Dia. A 2.88 4.0 5.5 B 2.25 3.38 4.75 C1 1.07 1.98 3.11 C2 1.88 3.60 5.76 C3 2.70 5.21 8.48 D 1.75 3.32 2.94 Loadside E 0.82 1.62 2.69 F 0.54 0.99 1.55 G 0.32 0.31 0.36 H 0.84 0.88 1.19 J K L 0.31 0.20 0.41 0.35 Slot 0.20” wide x 0.41” long Slot 0.42” wide x 0.62” long 0.44 Slot 0.20” wide x 0.33” long Slot 0.41” wide x 0.53” long Eaton.com/bussmannseries 3 Technical Data 10534 Splicer blocks Effective January 2019 Optional covers From the table below, order the cover catalog number that matches the block catalog number. Block catalog number 16000-2 16000-3 16000-4 16003-2 16003-3 16003-4 16005-2 16005-3 16005-4 16200-1 16200-2 16200-3 16201-1 16201-2 16201-3 16204-1 16204-2 16204-3 16301-1 16301-2 16301-3 16303-1 16303-2 16303-3 16306-1 16306-2 16306-3 16500-1 16500-2 16500-3 16504-1 16504-2 16504-3 Poles 2 3 4 2 3 4 2 3 4 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 Cover catalog number CPB160-2* CPB160-3* CPB160-4* CPB160-2* CPB160-3* CPB160-4* CPB160-2* CPB160-3* CPB160-4* CPB162-1* CPB162-2* CPB162-3* CPB162-1* CPB162-2* CPB162-3* CPB162-1* CPB162-2* CPB162-3* CPDB-1* CPDB-2* CPDB-3* CPDB-1* CPDB-2* CPDB-3* CPDB-1* CPDB-2* CPDB-3* CPDB165** CPDB165** CPDB165** CPDB165** CPDB165** CPDB165** * Cover catalog number provides one individual cover for each block. ** Order one cover for each pole. The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States Eaton.com/bussmannseries © 2019 Eaton All Rights Reserved Printed in USA Publication No. 10534 — BU-MC16057 Janaury 2019 Eaton.com/bussmannseries Eaton and Bussmann are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. CSA is a registered trademark of the Canadian Standards Group. UL is a registered trademark of the Underwriters Laboratories, Inc. For Eaton’s Bussmann series product information, call 1-855-287-7626 or visit: Eaton.com/bussmannseries Follow us on social media to get the latest product and support information.
16582-2 价格&库存

很抱歉,暂时无法提供与“16582-2”相匹配的价格&库存,您可以联系我们找货

免费人工找货