Types H & BT .652" (16.56mm) Center-to-Center Spacing
High Voltage/Current
Features:
Sectional, High and Medium Power Terminal Blocks –
Designed for high power applications and control/power
circuits respectively. Units approach power ratings of larger
terminal blocks whlie retaining increased circuit density of
low power designs.
Broad Terminal Choice – One thru 30 terminals on .652"
center-to-center spacing with white fiber circuit marking
strips.
Thru-Bolt Barrier-Type Construction – Rated at
75A/600V for Type H; 30A/600V for Type BT.
Unique Bar and Traveling Collar Design – Eliminates
lugging of wire on Type H. UL recognized for No. 16AWG to
No. 4AWG. Type BT uses two No. 10-32 terminal screws,
UL recognized for No. 22AWG to No. 10AWG.
Combined Style Flexibility – Types can be used in
combination as well as be combined with types L, O, S, T &
U for greater application flexibility.
Recognition and Listing – UL recognized and CSA
certified
TYPE H
Recognized under the Components Program of
Underwriters Laboratories, Inc. Standard 1059,
Guide No. XCFR2, File No. E62557.
BARRIER STYLE
Guide No. 184-N-90, Report No. LR39186-1.
TERMINAL DESIGNATIONS
TYPE BT
H
Types H & BT Terminal Variations
H
high-presure
solderless connector
BT
Brass bar with high-pressure solderless connectors
accepting wire form No. 16AWG to 4AWG.
Brass terminal bar with two No. 10-32 plated steel
terminal screws accepting wire up to No. 10AWG.
Types H & BT Dimensions
O.D.
BT
terminal bar with two
No. 10-32 screws
.25
(6.35)
1.25
(31.75)
M.D.
1.50 1.00
(38.1) (25.4)
.218 x .375 Lg. Mtg. Holes
(5.53) x (9.52)
.652
(16.56)
.50
(12.7)
Marking Strip
NOTE: mm dim. are shown in parentheses
46
www.curtisind.com
Curtis Industries
A Division of Powers Holdings, Inc.
6SHci¿cDtionssuEMHcttocKDnJH.
Dimensions are shown for
reference purposes only.
6SeFi¿Fations:
Number of
Terminals
Mounting
Dimensions
Inches
Types H and BT terminal blocks are ordered by listing a
model number made up of the model designation followed by
the number of terminals required for the application.
Example: a 10-pole terminal block becomes H-10 or BT-10
When ordering combinations of both types, the model
number is made up of both model designations followed by
total number of poles and number of each type.A composite
of three H terminals followed by two BT terminals thus is
converted to stock number HBT-5 (3H, 2BT).
Inches
Metric
(mm)
1
1.66
42.1
2.36
59.8
2
2.31
58.6
3.01
76.4
3
2.96
75.1
3.66
92.9
4
3.61
91.6
4.31
109.4
5
4.26
108.1
4.96
126.0
6
4.91
124.6
5.61
142.5
7
5.56
141.1
6.26
159.1
8
6.21
157.6
6.92
175.6
9
6.86
174.1
7.57
192.2
10
7.51
190.6
8.22
208.7
11
8.16
207.1
8.87
225.3
12
8.81
223.6
9.52
241.8
13
9.46
240.2
10.17
258.4
14
10.10
256.6
10.82
274.9
15
10.75
273.2
11.48
291.5
16
11.40
289.7
12.13
308.0
17
12.05
306.2
12.78
324.6
18
12.70
322.7
13.43
341.1
19
13.35
339.2
14.08
357.7
20
14.00
355.7
14.73
374.2
21
14.65
372.2
15.39
390.8
22
15.30
388.7
16.04
407.3
23
15.95
405.2
16.69
423.9
24
16.60
421.7
17.34
440.4
25
17.25
438.2
17.99
457.0
26
17.40
454.7
18.64
473.5
27
18.55
471.2
19.29
490.1
28
19.20
487.7
19.95
506.6
29
19.85
504.2
20.60
523.2
30
20.50
520.7
21.25
539.7
BARRIER STYLE
How to Order
Metric
(mm)
Overall
Dimensions
High Voltage/Current
Center-to-Center Spacing: .652" (16.56mm)
Wire Range:
H: UL Recognized for 16AWG to No. 4AWG
HT: UL Recognized for 22AWG to No. 10AWG
No. of Terminals: 1 thru 30
Voltage Rating: CSA: 600V
UL: 600V General Industrial
Tightening Torque:
TH: 45 in.-lb. (4WG to 6AWG)
40 in.-lb. (8AWG)
35 in.-lb. (10AWG to 16AWG)
BT: 20 in. - lbs.
Current Rating: H: 75 amps
BT: 30 amps, UL and CSA.
Housing:
Material
Thermoplastic-Polyester
Continuous Use
Temp. (UL Index)
130°C (266°F)
Flammability Rating
94V-0
Water Absorption
(24 hrs. % wt. gain) 0.7%
Chemical Resistance
Excellent in most environments
Breakdown Voltage:
BT
H
Terminal - Terminal
10,400V Typ. 8,100V Typ.
Terminal - Ground
8,400V Typ. 7,600V Typ.
Note: Speci¿cations contained herein are subMect to change
without notice.
Dimensions shown are ± 0.030"
Series H & BT Accessories
COVERS
Series H & BT – Two cover styles. Hinged cover of 3/16" thick
black bakelite pivoting from special end brackets provide
ready access to block. Factory-assembled and available only
with original terminal block order. Plain cover of 1/16" thick
black bakelite is permanently positioned to block with two
screws. Factory-assembled or customer-installed.
To order, specify:
H/BT (Plain) – Part No. 260A49 – 1 thru 30 terminals
H (Hinged) – Part No. 260A56 – 1 thru 30 terminals
BT (Hinged) – Part No. 250A122 – 1 thru 30 terminals
Dimensions are in inches and millimeters
unless otherwise speci¿ed.
Values in parentheses are metric equivalents.
Curtis Industries
A Division of Powers Holdings, Inc.
1-800-657-0853
47
很抱歉,暂时无法提供与“BT-27”相匹配的价格&库存,您可以联系我们找货
免费人工找货