0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FN9290-10-06

FN9290-10-06

  • 厂商:

    SCHAFFNER(夏弗纳)

  • 封装:

    -

  • 描述:

    PWR ENT MOD RCPT IEC320-C14 PNL

  • 数据手册
  • 价格&库存
FN9290-10-06 数据手册
DATA SHEET Power Entry Module with EMC- Filter FN9290 Ultra Compact and Versatile Filtered Power Entry Module Dual stage filter Approvals & Compliances Ultra compact design Rated currents up to 10 A Dual fuse holder 2-pole rocker switch Good attenuation performance Faston or spring cage terminals Performance indicators (CQC except HI-types; Patent US 20110227692/US 8766761; CN ZL201080069589.0) Choosing FN 9280/90 product line brings you the rapid availability of a standard filter associated with the necessary safety acceptances and a high attenuation performance. For higher attenuation performance the FN 9290 family with a dual stage filter and identical panel cut-out can be used. Standard IEC connector filters are a practical solution to pass EMI system approval in a short time. A wide selection of amperage ratings, mounting possibilities and also filters for medical applications are designed to offer you the best solution. Features and Benefits Best conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior Technical Specifications Maximum continuous operating voltage 250 VAC, 50/60 Hz Rated currents Deep-drawn iron-sheet housing for best possible shielding against magnetic fields 1 to 10 A @ 40°C max Operating frequency Rear/front flange mounting or snap-in versions DC to 400 Hz Dual and additional spare fuse holder Leakage current Standard: PE 2500 VAC for 2 sec (B types) P –> N 760 VAC for 2 sec FN 929X B versions comply with the requirements of 1MOP acc. to IEC/EN 60601-1 Design corresponding to UL 1283, CSA 22.2 No. 8 1986, EN 60939, EN 60950, EN 60601-1, UL 544, EN 60320 Flammability corresponding to UL 94 V-2 or better Temperature range (operation and storage) – 25°C to +85°C (25/85/21) Protection category IP 40 according to IEC 60529 (front side) Portable electrical and electronic equipment MTBF @ 40°C/230 V (Mil-HB-217F) > 1,000,000 hours Consumer goods All versions according IEC/EN 62368-1 Typical Applications EDP and office equipment Switch ratings * Faston or spring cage terminals for more flexible assembly Rocker switch 2-pole, dark not illuminated, Marking I - 0 Single-phase and switch-mode power supplies USA (UL) and Canada (C-UL) 10 A, 125 VAC; 10 A, 250 VAC; 1/3 HP Test and measurement equipment Europe (ENEC) 10 A (4 A), 250 VAC* Mechanical life 50,000 cycles Medical electrical devices (MD) and InVitro-Diagnostics (IVD) equipment Electrical specifications Inrush current 82 A 6,000 on-off operations according to UL 1054 10,000 on-off operations according to ENEC Fuse holder 2 fuses (Ø5 x 20 mm) max. 250 V (certified to IEC 60127-6), power acceptance 1.6W @ Ta 23°C per pole Value in () relates to the inductive current charge: cos γ = 0.65 Audio/Video, information and communication technologies Typical electrical schematic 2 Power Entry Module with EMC- Filter Schaffner Group DATA SHEET 24. Nov 2022 Filter Selection Table Filter* Rated current Leakage current** @ 40°C @ 250 VAC /50 Hz Inductance Capacitance Resistance Output Weight connections L1 L2 Cx Cy1 Cy2 R (@ 120 VAC /60 Hz) [A] [mA] [mH] [mH] [nF] [nF] [nF] [kOhm] FN 9290-1-.. 1 0.28 (0.16) 10.9 10.9 220 1.5 0.47 1000 -06 -100 147 [g] FN 9290-2-.. 2 0.28 (0.16) 4.4 4.4 220 1.5 0.47 1000 -06 -100 148 FN 9290-4-.. 4 0.28 (0.16) 1.7 1.7 220 1.5 0.47 1000 -06 -100 148 FN 9290-6-.. 6 0.28 (0.16) 0.78 0.78 220 1.5 0.47 1000 -06 -100 153 FN 9290-10-.. 10 0.28 (0.16) 0.32 0.32 220 1.5 0.47 1000 -06 -100 154 FN 9290 B-1-.. 1 0.00 10.9 10.9 220 0 0 1000 -06 -100 147 FN 9290 B-2-.. 2 0.00 4.4 4.4 220 0 0 1000 -06 -100 148 FN 9290 B-4-.. 4 0.00 1.7 1.7 220 0 0 1000 -06 -100 148 FN 9290 B-6-.. 6 0.00 0.78 0.78 220 0 0 1000 -06 -100 153 FN 9290 B-10-.. 10 0.00 0.32 0.32 220 0 0 1000 -06 -100 154 FN 9299-1-.. 1 0.28 (0.16) 10.9 10.9 220 1.5 0.47 1000 -06 -100 147 FN 9299-2-.. 2 0.28 (0.16) 4.4 4.4 220 1.5 0.47 1000 -06 -100 148 FN 9299-4-.. 4 0.28 (0.16) 1.7 1.7 220 1.5 0.47 1000 -06 -100 148 FN 9299-6-.. 6 0.28 (0.16) 0.78 0.78 220 1.5 0.47 1000 -06 -100 153 FN 9299-10-.. 10 0.28 (0.16) 0.32 0.32 220 1.5 0.47 1000 -06 -100 154 FN 9299 B-1-.. 1 0.00 10.9 10.9 220 0 0 1000 -06 -100 147 FN 9299 B-2-.. 2 0.00 4.4 4.4 220 0 0 1000 -06 -100 148 FN 9299 B-4-.. 4 0.00 1.7 1.7 220 0 0 1000 -06 -100 148 FN 9299 B-6-.. 6 0.00 0.78 0.78 220 0 0 1000 -06 -100 153 FN 9299 B-10-.. 10 0.00 0.32 0.32 220 0 0 1000 -06 -100 154 * To compile a complete part number, please replace the -.. with the required output connection style (e.g. FN 9289-1-06, FN 9282-4-100) ** Maximum leakage current under normal conditions (according to IEC60939-3) Product selector: 3 Power Entry Module with EMC- Filter Schaffner Group DATA SHEET 24. Nov 2022 All FN 9280/FN 9290 are equipped with a dual fuse holder with a spare fuse holder. Note: All FN 9280/FN 9280 B/FN 9289/FN 9289 B/FN 9290/FN 9290 B/FN 9299/FN 9299 B are stock types from our distribution partners. Order Examples: FN 9280 B-6-100: Medical version of single stage, dual fuse EMC/EMI filter, flange set for vertical/horizontal/front/rear mounting, 6 A, spring cage terminals, from stock available. FN 9298-6-06-30: Dual stage, dual fuse EMC/EMI filter, snap-in version, snappers for snap-in panel thickness range >2.5 to 3.5 mm, snapper on vertical side, 6 A, fast-on terminals, non-stock order type Accessories: The 4D flanges can be ordered separately. The order number is 427532. Please note that the minimum order quantity is one box of 50 pieces. One item includes both type of flanges (vertical and horizontal). Typical Filter Attenuation FN 9290 Series | Typical filter attenuation | Per CISPR 17; A=50 Ω/50 Ω sym; B=50 Ω/50 Ω asym 1 A types 2 A types 4 – 6 A types 10 A types B A FN 9290 B Series | Typical filter attenuation | Per CISPR 17; A=50 Ω/50 Ω sym; B=50 Ω/50 Ω asym 1 A types 2 A types 4 – 6 A types 10 A types B A 4 Power Entry Module with EMC- Filter Schaffner Group DATA SHEET 24. Nov 2022 Mechanical Data FN 9290-x-06/FN 9290 B-x-06 FN 9290-x-100/FN 9290 B-x-100 FN 9299-x-06/FN 9299 B-x-06 FN 9299-x-100/FN 9299 B-x-100 5 Power Entry Module with EMC- Filter Schaffner Group DATA SHEET 24. Nov 2022 Assembly Instructions Terminal -100 clamping range, solid wire / flex wire 0,20 mm² –1,5 mm², AWG24 –AWG16 operating force of slider recommended stripped length Removal Of The Combined Switch / Fuse Holder Unit max. 40 N Push the knob above the terminal to insert the wire. 8 mm An additional fuse mark on the switch indicates the fuses holders behind the switch. The red frame shows the outline of the removable unit. With a simple tool like a Swiss Army knife or a screwdriver No 1 or smaller the unit (1) can be removed from the filter. On the topside (2) behind the switch there are two fuse holders for each live connection. On the bottom side (3) is a clip to carry an additional spare fuse. Please visit www.schaffner.com to find more details on filter connectors. 6 Power Entry Module with EMC- Filter Schaffner Group DATA SHEET 24. Nov 2022 Accessories IL 13P IEC C13 R Re ewir wireable eable Connec Connecttors with LLock ocking ing Syst System em The locking system has a tensile force of typical 300N. It is recommended to use it with flange mount filters. For details refer to our Application Note "Using IEC Lock Power Cords with IEC Inlets and Filters". Schaffner power connector with IEC lock guard against accidental disconnection of all electrical appliances with an IEC inlet. No exchange or modification of the IEC inlet or IEC inlet filter system is needed. Easy retrofit .for all electronic equipments and devices Technical Data Sheet > IL 13P IEC C13 R Re ewir wireable eable Angled Connec Connecttors with LLock ocking ing Syst System em Protects appliances that are vulnerable to vibration Connector cannot be accidentally pulled or vibrated out of the inlet Space availability/constraints Different angles for ease of access Space saving Release locking mechanism Prevents accidental disconnection Technical Data Sheet > Power Cor Cord d with angled LLock ocking ing Syst System em C13 Protects appliances that are vulnerable to vibration Connector cannot be accidentally pulled or vibrated out of the inlet Space availability/constraints Different angles for ease of access Space saving Release locking mechanism Prevents accidental disconnection Technical Data Sheet > 7 Power Entry Module with EMC- Filter Schaffner Group DATA SHEET 24. Nov 2022 Headquarters, Global Innovation and Development Switzerland Schaffner Group Industrie Nord Nordstrasse 11e 4542 Luterbach +41 32 681 66 26 info@schaffner.com Sales and Application Centers China Schaffner EMC Ltd. Shanghai T20-3 C No 565 Chuangye Road Pudong district 201201 Shanghai +86 2138139500 cschina@schaffner.com Spain Schaffner EMC España Calle Caléndula 93 Miniparc III Edificio E El Soto de Moraleja Alcobendas 28109 Madrid +34 917 912 900 spainsales@schaffner.com Finland Schaffner Oy Sauvonrinne 19 H 8500 Lohja +358 50 468 7284 finlandsales@schaffner.com Sweden Schaffner EMC AB Östermalmstrorg 1 114 42 Stockholm +46 8 5050 2425 swedensales@schaffner.com France Schaffner EMC S.A.S. 16-20 Rue Louis Rameau 95875 Bezons +33 1 34 34 30 60 francesales@schaffner.com Switzerland Schaffner EMV AG Industrie Nord Nordstrasse 11e 4542 Luterbach +41 32 681 66 26 switzerlandsales@schaffner.com Germany Schaffner Deutschland GmbH Schoemperlenstrasse 12B 76185 Karlsruhe +49 721 56910 germanysales@schaffner.com India Schaffner India Pvt. Ltd Regus World Trade Centre WTC 22nd Floor Unit No 2238 Brigade Gateway Campus 26/1 Dr. Rajkumar Road Malleshwaram (W) 560055 Bangalore +91 8067935355 indiasales@schaffner.com To find your local partner within Schaffner‘s global network schaffner.com © 2022 Schaffner Group The content of this document has been carefully checked and understood. However, neither Schaffner nor its subsidiaries assume any liability whatsoever for any errors or inaccuracies of this document and the consequences thereof. Published specifica-tionsw are subject to change without notice. Product suitability for any area of application must ultimately be determined by the customer. In all cases, products must never be operated outside their published specifications. Schaffner does not guarantee the availability of all published products. This disclaimer shall be governed by substantive Swiss law and resulting disputes shall be settled by the courts at the place of business of Schaffner Holding AG. Latest publications and a complete disclaimer can be downloa-ded from the Schaffner website. All trademarks recognized. Italy Schaffner EMC S.r.l. Via Ticino, 30 20900 Monza (MB) +39 039 21 41 070 italysales@schaffner.com Japan Schaffner EMC K.K. ISM Sangenjaya 7F 1-32-12 Kamiuma Setagaya-ku 154-0011 Tokyo +81 3 5712 3650 japansales@schaffner.com Singapore Schaffner EMC Pte Ltd. Blk 3015A Ubi Road 1 #05-09 Kampong Ubi Industrial Estate 408705 Singapore +65 63773283 singaporesales@schaffner.com Taiwan Schaffner EMV Ltd. U-Town 20 Floor-2 No 97 Section 1 XinTai 5th Road XiZhi District 22175 New Taipei City +886 226975500 taiwansales@schaffner.com Thailand Schaffner EMC Co. Ltd. Sathorn Square Tower Room 3780 37FL 98 North-Sathorn Rd Silom Bangrak 10500 Bangkok +66 621056397 thailandsales@schaffner.com United Kingdom Schaffner Ltd. Suite 1 Oakmede Place Terrace Road RG42 4JF Binfield +44 118 9770070 uksales@schaffner.com United States Schaffner EMC Inc. 52 Mayfield Avenue Edison, New Jersey +1 732 225 9533 usasales@schaffner.com
FN9290-10-06 价格&库存

很抱歉,暂时无法提供与“FN9290-10-06”相匹配的价格&库存,您可以联系我们找货

免费人工找货
FN9290-10-06
    •  国内价格
    • 1+358.69319
    • 10+353.17133
    • 20+345.52937

    库存:19