FN284E-6-06 数据手册
DATA SHEET Power Entry Module with EMC- Filter FN280 Compact filtered power entry module Complies with IEC/EN 60601-1 Approvals & Compliances Rated currents up to 10 A Single or dual-fuse holder Fuses Ø5 x 20 mm 2-pole rocker switch General purpose application Optional earth line choke (E type) Optional medical versions (B type) (CQC except HI-types) Features and Benefits High conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior Rear/front or snap-in mounting Performance indicators Single or dual-fuse holder 2-pole rocker switch Custom-specific versions are available on request Typical Applications Portable electrical and electronic equipment Consumer goods EDP and office equipment Single-phase power supplies, switch-mode power supplies Test and measurement equipment Medical equipment Technical Specifications Typical electrical schematic Maximum continuous operating voltage 250 VOLT, 50/60 Hz Operating frequency DC to 400 Hz Rated currents 1 to 10 A @ 40°C max High potential test voltage P –> PE 2000 VAC for 2 sec (standard types) P –> PE 2500 VAC for 2 sec (B types) P –> N 760 VAC for 2 sec Protection category IP 40 according to IEC 60529 Temperature range (operation and storage) -25°C to +85°C (25/85/21) Design corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 Flammability corresponding to UL 94 V-2 or better MTBF @ 40°C/230 V (Mil-HB-217F) 1,500,000 hours Fuse holder 1 or 2 fuses (Ø5 x 20 mm) (certified to IEC 60127-6), power acceptance 1.6W @ Ta 23°C per pole for 2 fuses. 2.5W, if only 1 pole is used. Marking ) Marking max. 250 V ~ (text is print. below fuse symbol) Rocker switch description Function 2-pole, dark not illuminated Marking I - 0 Electrical specifications Inrush current 82 A 6,000 on-off operations according to UL 1054, TV5 10,000 on-off operations according to ENEC Switch ratings * USA (UL) and Canada (C-UL) 10 A, 125 VAC; 10 A, 250 VAC; 1/3 HP Europe (ENEC) 10 A (4 A), 250 VAC* Mechanical life 50,000 cycles Value in () relates to the inductive current charge: cosφ = 0.65 2 Power Entry Module with EMC- Filter Schaffner Group DATA SHEET 24. Nov 2022 Filter Selection Table Filter Rated current Leakage current* @ 40°C (25°C) @ 230 VAC/50 Hz L1 L2 Cx [A] [μA] [mH] [mH] [nF] FN 281-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 FN 281-2-06 2 (2.4) 373 2 220 2.2 1000 FN 281-4-06 4 (4.8) 373 1 220 2.2 1000 FN 281-6-06 Inductance** Capacitance** Resistance** Output Fuses*** Weight Cy R connections [nF] [kΩ] [Qty] [g] 1 90 -06 1 90 -06 1 90 6 (7.2) 373 0.45 220 2.2 1000 -06 1 90 10 (11.6) 373 0.34 220 2.2 1000 -06 1 90 FN 282-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 2 90 FN 282-2-06 2 (2.4) 373 2 220 2.2 1000 -06 2 90 FN 282-4-06 4 (4.8) 373 1 220 2.2 1000 -06 2 90 FN 281-10-06 FN 282-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 2 90 10 (11.6) 373 0.34 220 2.2 1000 -06 2 90 FN 283-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 1 90 FN 283-2-06 2 (2.4) 373 2 220 2.2 1000 -06 1 90 FN 283-4-06 4 (4.8) 373 1 220 2.2 1000 -06 1 90 FN 283-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 1 90 10 (11.6) 373 0.34 220 2.2 1000 -06 1 90 FN 284-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 2 90 FN 284-2-06 2 (2.4) 373 2 220 2.2 1000 -06 2 90 FN 284-4-06 4 (4.8) 373 1 220 2.2 1000 -06 2 90 FN 284-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 2 90 10 (11.6) 373 0.34 220 2.2 1000 -06 2 90 FN 285-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 1 90 FN 285-2-06 2 (2.4) 373 2 220 2.2 1000 -06 1 90 FN 285-4-06 4 (4.8) 373 1 220 2.2 1000 -06 1 90 FN 282-10-06 FN 283-10-06 FN 284-10-06 FN 285-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 1 90 10 (11.6) 373 0.34 220 2.2 1000 -06 1 90 FN 286-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 2 90 FN 286-2-06 2 (2.4) 373 2 220 2.2 1000 -06 2 90 FN 286-4-06 4 (4.8) 373 1 220 2.2 1000 -06 2 90 FN 285-10-06 FN 286-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 2 90 FN 286-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 2 90 FN 283 E-1-06 1 (1.2) 373 7.5 0.4 220 2.2 1000 -06 1 100 FN 283 E-2-06 2 (2.4) 373 2 0.4 220 2.2 1000 -06 1 100 FN 283 E-4-06 4 (4.8) 373 1 0.4 220 2.2 1000 -06 1 100 FN 283 E-6-06 6 (7.2) 373 0.45 0.4 220 2.2 1000 -06 1 100 FN 284 E-1-06 1 (1.2) 373 7.5 0.4 220 2.2 1000 -06 2 100 FN 284 E-2-06 2 (2.4) 373 2 0.4 220 2.2 1000 -06 2 100 FN 284 E-4-06 4 (4.8) 373 1 0.4 220 2.2 1000 -06 2 100 FN 284 E-6-06 6 (7.2) 373 0.45 0.4 220 2.2 1000 -06 2 100 FN 282 B-1-06 1 (1.2) 2 7.5 220 1000 -06 2 90 FN 282 B-2-06 2 (2.4) 2 2 220 1000 -06 2 90 FN 282 B-4-06 4 (4.8) 2 1 220 1000 -06 2 90 6 (7.2) 2 0.45 220 1000 -06 2 90 10 (11.6) 2 0.34 220 1000 -06 2 90 FN 282 B-6-06 FN 282 B-10-06 *** Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. *** Tolerances apply: Inductance: -30/+50%, Capacitance: ±20%, Resistance: ±10% *** Filters are delivered without fuse. 3 Power Entry Module with EMC- Filter Schaffner Group DATA SHEET 24. Nov 2022 Filter Rated current Leakage current* @ 40°C (25°C) @ 230 VAC/50 Hz L1 L2 Cx [A] [μA] [mH] [mH] [nF] FN 284 B-1-06 1 (1.2) 2 7.5 220 1000 FN 284 B-2-06 2 (2.4) 2 2 220 1000 FN 284 B-4-06 4 (4.8) 2 1 220 FN 284 B-6-06 Inductance** Capacitance** Resistance** Output Fuses*** Weight Cy R connections [nF] [kΩ] [Qty] [g] -06 2 90 -06 2 90 1000 -06 2 90 6 (7.2) 2 0.45 220 1000 -06 2 90 10 (11.6) 2 0.34 220 1000 -06 2 90 FN 286 B-1-06 1 (1.2) 2 7.5 220 1000 -06 2 90 FN 286 B-2-06 2 (2.4) 2 2 220 1000 -06 2 90 FN 286 B-4-06 4 (4.8) 2 1 220 1000 -06 2 90 FN 286 B-6-06 6 (7.2) 2 0.45 220 1000 -06 2 90 10 (11.6) 2 0.34 220 1000 -06 2 90 FN 284 B-10-06 FN 286 B-10-06 *** Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. *** Tolerances apply: Inductance: -30/+50%, Capacitance: ±20%, Resistance: ±10% *** Filters are delivered without fuse. Product selector For example: FN 281-6-06, FN 283 B-04-06, FN 283 E-1-06 Typical Filter Attenuation Per CISPR 17; A=50 Ω/50 Ω sym; B=50 Ω/50 Ω asym; C=0.1 Ω/100 Ω sym; D=100 Ω/0.1 Ω sym 1 A types 2 to 6 A types 10 A types 4 Power Entry Module with EMC- Filter Schaffner Group DATA SHEET 24. Nov 2022 Mechanical Data FN 281/FN 282 FN 283/FN 284 FN 285/FN 286 Panel cut out Dimensions FN 281 FN 282 FN 283 FN 284 FN 285 FN 286 Tolerances A 32 32 50 50 32 32 ±0.3 B 82 82 65 65 65 65 ±0.3 C 72 72 40 40 D 43.1 43.1 43.1 43.1 43.6 43.6 ±0.3 E 28.5 28.5 28.5 28.5 28.5 28.5 ±0.25 F 5.5 5.5 5.5 5.5 5 5 ±0.3 G 59.95 max. 59.95 max. 59.95 max. 59.95 max. 59.95 max. 59.95 max. H Ø3.5 Ø3.5 Ø3.3 Ø3.3 I 13.4 16.2 13.4 16.2 13.9 16.7 J 22.5 22.5 22.5 22.5 22.5 22.5 M R ≤2.5 R ≤2.5 R ≤2.5 R ≤2.5 R ≤2.5 R ≤2.5 N 60 60 60 60 61.5+0.2/-0* 61.5+0.2/-0* +0.5/-0 P 29 29 29 29 29 29 +0.5/-0 R M3 M3 M3 M3 S 90° 90° 90° 90° * For a panel thickness between 0.8 and 3 mm All dimensions in mm; 1 inch = 25.4 mm Tolerances according: ISO 2768-m/EN 22768-m Please visit www.schaffner.com to find more details on filter connectors. ±0.1 ±0.3 5 Power Entry Module with EMC- Filter Schaffner Group DATA SHEET 24. Nov 2022 Headquarters, Global Innovation and Development Switzerland Schaffner Group Industrie Nord Nordstrasse 11e 4542 Luterbach +41 32 681 66 26 info@schaffner.com Sales and Application Centers China Schaffner EMC Ltd. Shanghai T20-3 C No 565 Chuangye Road Pudong district 201201 Shanghai +86 2138139500 cschina@schaffner.com Spain Schaffner EMC España Calle Caléndula 93 Miniparc III Edificio E El Soto de Moraleja Alcobendas 28109 Madrid +34 917 912 900 spainsales@schaffner.com Finland Schaffner Oy Sauvonrinne 19 H 8500 Lohja +358 50 468 7284 finlandsales@schaffner.com Sweden Schaffner EMC AB Östermalmstrorg 1 114 42 Stockholm +46 8 5050 2425 swedensales@schaffner.com France Schaffner EMC S.A.S. 16-20 Rue Louis Rameau 95875 Bezons +33 1 34 34 30 60 francesales@schaffner.com Switzerland Schaffner EMV AG Industrie Nord Nordstrasse 11e 4542 Luterbach +41 32 681 66 26 switzerlandsales@schaffner.com Germany Schaffner Deutschland GmbH Schoemperlenstrasse 12B 76185 Karlsruhe +49 721 56910 germanysales@schaffner.com India Schaffner India Pvt. Ltd Regus World Trade Centre WTC 22nd Floor Unit No 2238 Brigade Gateway Campus 26/1 Dr. Rajkumar Road Malleshwaram (W) 560055 Bangalore +91 8067935355 indiasales@schaffner.com To find your local partner within Schaffner‘s global network schaffner.com © 2022 Schaffner Group The content of this document has been carefully checked and understood. However, neither Schaffner nor its subsidiaries assume any liability whatsoever for any errors or inaccuracies of this document and the consequences thereof. Published specifica-tionsw are subject to change without notice. Product suitability for any area of application must ultimately be determined by the customer. In all cases, products must never be operated outside their published specifications. Schaffner does not guarantee the availability of all published products. This disclaimer shall be governed by substantive Swiss law and resulting disputes shall be settled by the courts at the place of business of Schaffner Holding AG. Latest publications and a complete disclaimer can be downloa-ded from the Schaffner website. All trademarks recognized. Italy Schaffner EMC S.r.l. Via Ticino, 30 20900 Monza (MB) +39 039 21 41 070 italysales@schaffner.com Japan Schaffner EMC K.K. ISM Sangenjaya 7F 1-32-12 Kamiuma Setagaya-ku 154-0011 Tokyo +81 3 5712 3650 japansales@schaffner.com Singapore Schaffner EMC Pte Ltd. Blk 3015A Ubi Road 1 #05-09 Kampong Ubi Industrial Estate 408705 Singapore +65 63773283 singaporesales@schaffner.com Taiwan Schaffner EMV Ltd. U-Town 20 Floor-2 No 97 Section 1 XinTai 5th Road XiZhi District 22175 New Taipei City +886 226975500 taiwansales@schaffner.com Thailand Schaffner EMC Co. Ltd. Sathorn Square Tower Room 3780 37FL 98 North-Sathorn Rd Silom Bangrak 10500 Bangkok +66 621056397 thailandsales@schaffner.com United Kingdom Schaffner Ltd. Suite 1 Oakmede Place Terrace Road RG42 4JF Binfield +44 118 9770070 uksales@schaffner.com United States Schaffner EMC Inc. 52 Mayfield Avenue Edison, New Jersey +1 732 225 9533 usasales@schaffner.com
FN284E-6-06
物料型号:FN280系列,包括FN281、FN282、FN283、FN284、FN285、FN286等不同型号,具体型号根据额定电流和附加功能(如医疗版本B型、带接地线扼流器的E型)有所不同。

器件简介:这是一种带有EMC滤波器的电源输入模块,符合IEC/EN 60601-1标准,适用于一般用途,包括便携式电子设备、单相电源、医疗设备等。

引脚分配:文档中未明确列出引脚分配,但提到了单极或双极保险丝座,以及两极摇臂开关。

参数特性: - 最大持续工作电压:250V,50/60 Hz - 工作频率:直流至400 Hz - 额定电流:1至10安培在40°C最大值 - 高电位测试电压:标准型和医疗型(B型)有不同的测试电压要求 - 保护类别:IP 40 - 工作和存储温度范围:-25°C至+85°C

功能详解: - 提供高传导衰减性能,基于具有高饱和电阻和出色热性能的扼流器 - 可选的接地线扼流器(E型)和医疗版本(B型) - 两极摇臂开关,具有暗色未照明功能

应用信息:适用于便携式电子设备、单相电源、电子数据处理和办公设备、医疗设备、测试和测量设备、消费品等。

封装信息:文档提供了详细的机械数据,包括面板尺寸、安装方式(如IEC插头类型、EC插座、C14插座等)和面板开孔尺寸。
FN284E-6-06 价格&库存

很抱歉,暂时无法提供与“FN284E-6-06”相匹配的价格&库存,您可以联系我们找货