0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
60-BPP-010-5-4

60-BPP-010-5-4

  • 厂商:

    APITECHNOLOGIES

  • 封装:

    -

  • 描述:

    PWRENTRCPTIEC320-C14PNLSLDR

  • 详情介绍
  • 数据手册
  • 价格&库存
60-BPP-010-5-4 数据手册
Power Entry Modules The industry’s most complete line of power entry modules are ideal for products that must conform to FCC Part 15 regulations. These metal cased miniature filters offer high performance. Bolt-in Rear Terminals ............................................PF16-PF17 For General Purpose Applications ....................PF22-PF23 For Medical Applications ....................................PF24-PF25 Bolt-in Right Angle Terminals ................................PF18-PF19 For PCB Applications .........................................PF46-PF47 High Frequency Attenuation ..................................PF20-PF21 Bolt-in for PCB Applications ..............................PF48-PF49 Snap-in with Wire Leads.........................................PF26-PF27 Bolt-in with Wire Leads...........................................PF28-PF31 Snap-in Mount .........................................................PF32-PF33 Fused Filtered..........................................................PF34-PF37 For General Purpose Applications ....................PF34-PF35 For Medical or General Purpose Applications ......................................PF36-PF37 Switched and Fused Filtered .................................PF38-PF43 PCB Power Filters ...................................................PF44-PF45 Power Entry Modules Bolt-in Rear Terminals 60-BPR & BPS Series Features ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Solder lug and Fast-on tab terminals available Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF17) UL approved low leakage version also available Circuit Diagram 3 1 Applications ■ ■ ■ ■ CX Specifications Rated Voltage (@ 50/60Hz) Rated Current 60-XXX-010-3-2 60-XXX-010-3-4 250VAC E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units Model* CY 2 4 Leakage Current (Max.) CY Capacitance 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 60-XXX-010-5-4 0.35mA 250VAC 2200pF ± 20% 0.50mA 3300pF ± 20% 60-XXX-020-5-4 0.35mA 250VAC 2200pF ± 20% 0.50mA 3300pF ± 20% 60-XXX-030-5-4 30°C 1.2mH 30°C 0.53mH 45°C .022uF ± 20% 0.26mH 45°C .1uF ± 20% 0.15mH 45°C .022uF ± 20% .022uF ± 20% .022uF ± 20% .047uF ± 20% 60-XXX-060-3-2 0.35mA 250VAC 2200pF ± 20% .022uF ± 20% .047uF ± 20% 6A 60-XXX-060-5-2 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 60-XXX-060-5-4 60-BPR-150-3-11 2.4mH .022uF ± 20% .047uF ± 20% 3A 60-XXX-030-5-2 60-XXX-100-5-2 30°C .022uF ± 20% .047uF ± 20% 60-XXX-030-3-2 60-XXX-100-3-2 6.0mH .022uF ± 20% .047uF ± 20% 2A 60-XXX-020-5-2 60-XXX-060-3-4 Temperature Rise (Max.) .047uF ± 20% 60-XXX-020-3-2 60-XXX-030-3-4 Inductance (L1) CX .047uF ± 20% 1A 60-XXX-010-5-2 60-XXX-020-3-4 CY L1 .022uF ± 20% .047uF ± 20% 250VAC 10A 250VAC 15A Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 * Substitute BPR or BPS for XXX BPS - Solder lug terminals BPR - Fast-on tab terminals API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF16 Power Entry Modules Bolt-in Rear Terminals 60-BPR & BPS Series Temperature Characteristics 0.837 (21.3) 120 Current (%) 100 .944 (24) 80 60 1.967 (50) 20 30 40 50 60 70 Ambient Temperature (°C) 80 .157 (4) 1.10 (28) 1.181 (30) 1.573 (40) 20 * General tolerance ± .012 (0.3) 90 Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω 80 70 70 60-BPX-010-5-X 60-BPX-010-5-X Insertion Loss (dB) 60 50 40 60-BPX-020-5-X 30 60-BPX-030-5-X 20 60 50 40 60-BPX-020-5-X 30 60-BPX-030-5-X 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 5 10 20 50 60-BPX-060;-100 60-BPX-060;-100 80 80 70 70 Insertion Loss (dB) 60 60-BPX-060-5-X 50 40 30 60-BPX-100-5-X 20 60-BPX-060-X-4 60 50 60-BPX-060-X-2 40 60-BPX-100-X-2 30 20 10 10 0 0.1 2 Frequency (MHz) Frequency (MHz) Insertion Loss (dB) 50Ω Level Meter 50Ω 60-BPX-010;-020;-030 60-BPX-010;-020;-030 80 Insertion Loss (dB) 1.476 (37.5) (2x) .142 (3.6) 40 0 2.263 (57.5) .252 (6.4) .846 (21.5) 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF17 Power Entry Modules Bolt-in Right Angle Terminals 60-BPF Series Features ■ ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards PCB mounting types available (see page PF46) Length under tab is shortened for small spaces Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF19) UL approved low leakage version also available ■ ■ ■ Specifications Rated Voltage (@ 50/60Hz) Rated Current 60-BPF-010-3-2 60-BPF-010-3-4 250VAC E CY 2 4 Leakage Current (Max.) CY Capacitance 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 60-BPF-010-5-4 0.35mA 250VAC 2200pF ± 20% Temperature Rise (Max.) 6.0mH 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C .022uF ± 20% .022uF ± 20% .022uF ± 20% .047uF ± 20% 2A 60-BPF-020-5-2 0.50mA 3300pF ± 20% 60-BPF-020-5-4 .022uF ± 20% .047uF ± 20% 60-BPF-030-3-2 0.35mA 250VAC 2200pF ± 20% .022uF ± 20% .047uF ± 20% 3A 60-BPF-030-5-2 0.50mA 3300pF ± 20% 60-BPF-030-5-4 .022uF ± 20% .047uF ± 20% 60-BPF-060-3-2 60-BPF-060-3-4 Inductance (L1) .047uF ± 20% 60-BPF-020-3-2 60-BPF-030-3-4 CX .047uF ± 20% 1A 60-BPF-010-5-2 60-BPF-020-3-4 CY L1 E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units Model 3 1 CX Applications ■ Circuit Diagram 0.35mA 250VAC 2200pF ± 20% 6A 60-BPF-060-5-2 60-BPF-060-5-4 .022uF ± 20% .047uF ± 20% 0.50mA 3300pF ± 20% .022uF ± 20% .047uF ± 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF18 Power Entry Modules Bolt-in Right Angle Terminals 60-BPF Series 60-BPF Fast-on Terminals Temperature Characteristics 120 1.463 (37.2) 1.967 (50) 1.317 (33.5) 1.573 (40) .885 (22.5) Current (%) 100 2- .142 (3.6) 80 .047 (1.2) .232 (5.9) .024 (.6) .5 R4 .865 (22) 2- .142 (3.6) 1.573 (40) 40 * General tolerance ± .012 (.3) .142 .059 (3.6) (1.5) .031 (.8) 1.070 (27.2) 1.180 (30) 60 .991 (25.2) .590 (15) .779 1.180 (19.8) (30) .708 (18) Panel cutout dimensions mounts from backside 20 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 60-BPF-010;-020 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 60-BPF-010-3-X 60 50 60-BPF-020-3-X 40 30 20 10 60 60-BPF-010-X-4 50 40 30 60-BPF-020-X-4 20 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 5 10 20 50 20 50 60-BPF-030;-060 60-BPF-030;-060 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 2 Frequency (MHz) 80 60-BPF-030-3-X 50 40 60-BPF-060-3-X 30 20 60 50 40 60-BPF-030-X-4 30 60-BPF-060-X-4 20 10 10 0 0.1 50Ω Level Meter 50Ω 60-BPF-010;-020 80 0 0.1 50Ω 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF19 Power Entry Modules High Frequency Attenuation 60-BHS Series Features ■ ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 PCB mounting types available (see page PF48) PCB mounting minimizes space and provides economical installation Excellent filtering characteristics for high frequencies Earth coil standard Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF21) Applications ■ ■ ■ ■ Rated Voltage (@ 50/60Hz) Rated Current 60-BHS-010-3-11 250VAC E CY 2 4 L2 Leakage Current (Max.) CY Capacitance 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 60-BHS-010-5-4 0.35mA 250VAC 2200pF ± 20% Temperature Rise (Max.) 0.1uF ± 20% 6mH 18.3uH 30°C 2.4mH 18.3uH 30°C 1.2mH 18.3uH 30°C .53mH 18.3uH 45°C 0.1uF ± 20% 0.1uF ± 20% .047uF ± 20% 2A 60-BHS-020-5-11 0.50mA 3300pF ± 20% 60-BHS-020-5-4 0.1uF ± 20% .047uF ± 20% 60-BHS-030-3-11 0.35mA 250VAC 2200pF ± 20% 0.1uF ± 20% .047uF ± 20% 3A 60-BHS-030-5-11 0.50mA 3300pF ± 20% 60-BHS-030-5-4 0.1uF ± 20% .047uF ± 20% 60-BHS-060-3-11 60-BHS-060-3-4 Inductance (L1) (L2) .047uF ± 20% 60-BHS-020-3-11 60-BHS-030-3-4 CX .047uF ± 20% 1A 60-BHS-010-5-11 60-BHS-020-3-4 CY L1 CX Specifications 60-BHS-010-3-4 3 1 E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units Model Circuit Diagram 0.35mA 250VAC 2200pF ± 20% 6A 60-BHS-060-5-11 60-BHS-060-5-4 0.1uF ± 20% .047uF ± 20% 0.50mA 3300pF ± 20% 0.1uF ± 20% .047uF ± 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF20 Power Entry Modules High Frequency Attenuation 60-BHS Series Temperature Characteristics .098 (2.5) 1.967 (50) 1.573 (40) 120 .885 (22.5) Current (%) 100 1.180 (30) 60 .779 1.180 (19.8) (30) Panel cutout dimensions mounts from backside 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 Dimensions in inches (mm) 90 Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 60-BHS-XXX-X-11 90 50Ω 50Ω Level Meter 50Ω 60-BHS-XXX-3-11 80 80 60-BHS-010-X-11 70 Insertion Loss (dB) Insertion Loss (dB) 2- .142 (3.6) 1.573 (40) 20 60-BHS-020-X-11 60 50 40 60-BHS-030-X-11 30 60-BHS-060-X-11 70 60-BHS-010-3-11 60 50 60-BHS-020-3-11 40 60-BHS-030-3-11 30 60-BHS-060-3-11 20 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 60-BHS-XXX-X-4 90 80 0.5 1 2 5 10 20 50 60-BHS-XXX-3-4 80 Insertion Loss (dB) 60-BHS-010-X-4 70 60-BHS-020-X-4 60 50 40 60-BHS-030-X-4 30 60-BHS-060-X-4 70 60-BHS-010-3-4 60 50 60-BHS-020-3-4 60-BHS-030-3-4 30 60-BHS-060-3-4 20 10 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 * 40 20 0 0.1 0.2 Frequency (MHz) Frequency (MHz) Insertion Loss (dB) .031 (.8) .5 R4 .865 (22) 40 90 1.180 (30) 2- .142 (3.6) 80 90 1.534 (39) 1.389 (35.3) 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF21 Power Entry Modules Bolt-in Rear Terminals For General Purpose Applications 10-BPF Series Features ■ ■ ■ ■ ■ ■ Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Operating temperature: -25°C to +70°C Compact configuration Circuit Diagram CX CY Applications ■ ■ ■ ■ CY L1 1 Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CX CY L1 CX CY 2 CX CX L1 CY CY 3 Specifications Model 10-BPF-001-5-A Rated Rated Voltage Current (@ 50/60Hz) Leakage Current (Max.) Inductance Circuit (L1) Diagram 120/250VAC 1.5mH 0.50mA 10-BPF-006-5-A 6A 10A 4700pF 0.01uF 3300pF 3300pF 0.01uF Figure A 3.0mH 1 3A 10-BPF-003-5-C 10-BPF-010-5-A CX 3300pF 10-BPF-003-5-A 10-BPF-006-5-C Capacitance 2200pF 1A 10-BPF-001-5-C 10-BPF-003-5-D CY Temperature Rise (Max.) C A C 2 0.5mH 1 0.5mH 1 B A 30°C C A Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF22 Power Entry Modules Bolt-in Rear Terminals For General Purpose Applications 10-BPF Series Figure B M3 (2X) 1.6 (40) M3 (2X) 2.0 (52) 1.1 (28.5) +.01 -0.0 1.6 (40) ±.007 Figure A 2.0 (52) 1.4 (37) 2.8 (72) 1.25 (32) Figure C .80 (20.5) +.01 -0.0 1.4 (3.5) (2X) 2.3 (62) 1.9 1.6 .944 (50) (40) (24) 1.09 (27.8) .13 (3.5 (2X) 1.559 (39.6) 2.04 (52) .24 (6) 1.6 (40) Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 10-BPF-001;-003 10-BPF-001;-003 10-BPF-003-5-A 10-BPF-003-5-A 0.20.5 0.5 1 0 0.1 0.2 21 10-BPF-003-5-C 10-BPF-003-5-C 2 5 10 5 10 20 2050 50 Frequency Frequency (MHz) (MHz) 10 0 0.1 10-BPF-003-5-C 10-BPF-003-5-C 20 40 10 10 30 30 0 0 0.1 200.1 200.2 10 10-BPF-003-5-A 10-BPF-003-5-A Insertion Loss (dB) Loss (dB) Insertion 10-BPF-001;-003 10-BPF-001;-003 60 80 50 70 40 60 30 50 20 40 Insertion Loss (dB) Loss (dB) Insertion Insertion Loss (dB) Loss (dB) Insertion 70 10-BPF-001-5-A 10-BPF-001-5-A 60 80 10-BPF-001-5-C 10-BPF-001-5-C 50 70 10-BPF-001-5-A 10-BPF-001-5-A 40 60 10-BPF-001-5-C 10-BPF-001-5-C 30 50 0.2 0.5 0.51 1 2 2 5 510 80 80 70 70 10 20 20 50 10-BPF-001-5-A 10-BPF-001-5-A 10-BPF-001-5-C 10-BPF-001-5-C 40 60 30 50 20 40 10-BPF-001-5-A 10-BPF-001-5-A 0 0.1 0.2 10-BPF-003-5-C 10-BPF-003-5-C 0.20.5 0.5 1 0.2 0.5 0.51 5 10 1 2 2 5 510 10 20 2050 50 80 80 70 70 10-BPF-006-5-D 60 60 80 80 50 50 70 70 10-BPF-010-5-A 10-BPF-010-5-A 10-BPF-006-5-D 10-BPF-006-5-D 40 40 60 60 10-BPF-010-5-D 30 30 50 50 20 10-BPF-010-5-A 20 10-BPF-010-5-A 40 40 10-BPF-010-5-D 10 10 10-BPF-010-5-D 30 30 0 0 0.1 0.20.5 0.5 200.1 200.2 1 21 10 20 20 50 50 10-BPF-006;-010 10-BPF-006;-010 Insertion Loss (dB) Loss (dB) Insertion 10-BPF-006-5-D 80 10-BPF-006-5-A 10-BPF-006-5-A 10-BPF-006-5-D 10-BPF-006-5-D 50 70 10-BPF-006-5-C 10-BPF-006-5-C 40 60 10-BPF-006-5-A 30 10-BPF-006-5-A 50 10-BPF-006-5-C 10-BPF-006-5-C 20 40 10-BPF-010-5-A 10-BPF-010-5-A 10 10 30 30 10-BPF-010-5-D 0 0 0.1 0.20.5 2 5 0.5 5 200.1 200.2 1 21 10 10-BPF-010-5-A 10-BPF-010-5-A Frequency Frequency (MHz) (MHz) 10 10 10-BPF-010-5-D 10-BPF-010-5-D 0 0 0.1 0.2 1 2 5 0.5 510 0.1 0.2 1 2 0.5 2 5 10-BPF-006;-010 10-BPF-006;-010 10-BPF-006;-010 10-BPF-006;-010 60 60 80 50 70 40 60 30 50 20 40 10-BPF-003-5-A 10-BPF-003-5-A 10 2050 50 20 10-BPF-003-5-C 10-BPF-003-5-C Frequency Frequency (MHz) (MHz) 21 Frequency Frequency (MHz) (MHz) Insertion Loss (dB) Loss (dB) Insertion 70 Insertion Loss (dB) Loss (dB) Insertion Insertion Loss (dB) Loss (dB) Insertion 70 10-BPF-003-5-A 10-BPF-003-5-A 10-BPF-001-5-C 10-BPF-001-5-C 10 0 0.1 50 80 50 70 10 10 30 30 0 0 0.1 200.1 200.2 10 10-BPF-006;-010 10-BPF-006;-010 80 50Ω Level Meter 50Ω 10-BPF-001;-003 10-BPF-001;-003 60 60 80 50 70 40 60 30 50 20 40 Frequency Frequency (MHz) (MHz) 80 50Ω 10-BPF-001;-003 10-BPF-001;-003 80 70 .07 (2) Dimensions in inches (mm) Common Mode 80 1.1 (27) 1.9 (50) Insertion Loss (dB) Loss (dB) Insertion .62 (16) .82 (21) 1.8 (46) 10 10 20 20 50 50 0 0.1 10-BPF-006-5-C 10-BPF-006-5-C 2 5 5 10 Frequency Frequency (MHz) (MHz) 10 0 0.1 0.2 10-BPF-006-5-A 10-BPF-006-5-A 0.2 0.5 0.51 1 2 2 5 510 10-BPF-006-5-A 10-BPF-006-5-A 10 2050 50 20 10-BPF-006-5-C 10-BPF-006-5-C 10 20 20 50 50 API TECHNOLOGIES • 8061 Avonia Rd. •(MHz) Fairview, Frequency (MHz) PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com Frequency Frequency Frequency (MHz) (MHz) API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF23 Power Entry Modules Bolt-in Rear Terminals For Medical Purpose Applications 10-BPF Series Features ■ ■ ■ ■ ■ ■ ■ Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Operating temperature: -25°C to +70°C Compact configuration Low leakage current Circuit Diagram ■ ■ ■ ■ L1 Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units Specifications Model 10-BPF-001-2-A Rated Rated Voltage Current (@ 50/60Hz) 10-BPF-006-2-A 120/250VAC 3 1 Applications 1A 6A CX Leakage Current (Max.) Capacitance CX 5uA 0.01uF E E 2 4 Inductance (L1) Circuit Diagram Figure Temperature Rise (Max.) 1 A 30°C 3.0mH 0.5mH Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF24 Power Entry Modules Bolt-in Rear Terminals For Medical Purpose Applications 10-BPF Series M3 (2X) 1.1 (28.5) +.01 -0.0 1.6 (40) ±.007 .80 (20.5) +.01 -0.0 1.4 (3.5) (2X) 0.837 (21.3) 1.9 1.6 1.2 (50) (40) (30) Dimensions in inches (mm) 1.1 (28) 1.5 (37.5) .63 (16) Common Mode Normal Mode 1 3 Filter 2 4 1 3 Filter 2 4 Oscillator 50Ω 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω 50Ω 50Ω Level Meter 10-BPF-001; -006 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 10-BPF-001;-006 80 60 2.0 (51) .25 (6.5) .82 (21) 10-BPF-001-2-A 50 40 30 20 60 50 40 30 10-BPF-006-2-A 10-BPF-001-2-A 20 10-BPF-006-2-A 10 0 0.1 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF25 Power Entry Modules Snap-in with Wire Leads 60-SPL Series Features ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Snap-in style saves labor and hardware inventory Wire output minimizes space and provides economical installation Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF27) Applications ■ ■ ■ ■ Rated Voltage (@ 50/60Hz) Rated Current 60-SPL-010-3-2 250VAC E CY 2 4 Leakage Current (Max.) CY Capacitance 0.35mA 2200pF ± 20% CX 0.50mA 3300pF ± 20% 60-SPL-010-5-3 33nF ± 20% 22nF ± 20% 250VAC 2200pF ± 20% 33nF ± 20% 2A 60-SPL-020-5-2 0.50mA 3300pF ± 20% 60-SPL-020-5-3 0.35mA 250VAC 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C 22nF ± 20% 2200pF ± 20% .022uF ± 20% 3300pF ± 20% 3A 60-SPL-030-5-2 0.50mA 60-SPL-030-5-3 2200pF ± 20% .033uF ± 20% 3300pF ± 20% 60-SPL-060-3-2 60-SPL-060-3-3 6.0mH 33nF ± 20% 60-SPL-030-3-2 60-SPL-030-3-3 Temperature Rise (Max.) 22nF ± 20% 60-SPL-020-3-2 0.35mA Inductance (L1) 22nF ± 20% 33nF ± 20% 1A 60-SPL-010-5-2 60-SPL-020-3-3 CY L1 CX Specifications 60-SPL-010-3-3 3 1 E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units Model Circuit Diagram 0.35mA 250VAC 2200pF ± 20% 6A 60-SPL-060-5-2 60-SPL-060-5-3 22nF ± 20% 33nF ± 20% 0.50mA 3300pF ± 20% 22nF ± 20% 33nF ± 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF26 Power Entry Modules Snap-in with Wire Leads 60-SPL Series Temperature Characteristics .963 (24.5) * General tolerance ± .012 (.3) 120 .853 (21.7) .838 (21.3) Panel cutout dimensions 100 Current (%) R2 * Metal case Tin Plated 80 W T W .039 (1.0) 1.270 (32.3) .047 (1.2) 1.274 (32.4) .059 (1.5) 1.285 (32.5) T :Panel Thickness 1.612 (41) 4.719 (120)* .252 (6.4) 1.172 (29.8) .236 (6) 60 Blue UL 1015 AWG #18 1.397 (35.5) 40 Green/Yellow Brown 20 PVC Insulated wire * Custom lengths available upon request. 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 60-SPL-010-X-4 60-SPL-020-5-X 70 60-SPL-010-X-2 Insertion Loss (dB) Insertion Loss (dB) 60-SPL-010-5-X 50 60-SPL-010-3-X 40 30 20 60 50 60-SPL-020-X-4 40 30 60-SPL-020-X-2 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 5 10 20 50 60-SPL-030;-060 60-SPL-030;-060 80 80 60-SPL-030-X-4 60-SPL-030-5-X 70 70 60-SPL-030-3-X Insertion Loss (dB) 60 50 40 60-SPL-060-5-X 30 60-SPL-060-3-X 60 60-SPL-030-X-2 50 40 60-SPL-060-X-4 30 20 20 10 10 0 0.1 2 Frequency (MHz) Frequency (MHz) Insertion Loss (dB) 50Ω Level Meter 50Ω 80 60-SPL-020-3-X 60 50Ω 60-SPL-010;-020 60-SPL-010;-020 80 70 UL1617 AWG #22 60-SPL-060-X-2 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF27 Power Entry Modules Bolt-in with Wire Leads 60-BPL Series Features Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal case filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Wire output for minimizing space use and economical installation Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF28) ■ ■ ■ ■ ■ ■ Circuit Diagram 3 1 Applications ■ ■ ■ ■ CX Specifications Rated Voltage (@ 50/60Hz) Rated Current 60-BPL-010-3-2 60-BPL-010-3-3 250VAC E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units Model CY 2 4 Leakage Current (Max.) CY Capacitance 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 60-BPL-010-5-3 0.35mA 250VAC 2200pF ± 20% Temperature Rise (Max.) 6.0mH 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C 22nF ± 20% 22nF ± 20% 22nF ± 20% 33nF ± 20% 2A 60-BPL-020-5-2 0.50mA 3300pF ± 20% 60-BPL-020-5-3 22nF ± 20% 33nF ± 20% 60-BPL-030-3-2 0.35mA 250VAC 2200pF ± 20% .022uF ± 20% 3300pF ± 20% 3A 60-BPL-030-5-2 0.50mA 60-BPL-030-5-3 2200pF ± 20% .033uF ± 20% 3300pF ± 20% 60-BPL-060-3-2 60-BPL-060-3-3 Inductance (L1) 33nF ± 20% 60-BPL-020-3-2 60-BPL-030-3-3 CX 33nF ± 20% 1A 60-BPL-010-5-2 60-BPL-020-3-3 CY L1 0.35mA 250VAC 2200pF ± 20% 33nF ± 20% 6A 60-BPL-060-5-2 60-BPL-060-5-3 22nF ± 20% 0.50mA 3300pF ± 20% 22nF ± 20% 33nF ± 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF28 Power Entry Modules Bolt-in with Wire Leads 60-BPL Series .5 Temperature Characteristics .5 R4 .865 (22) 120 1.180 (30) 1.573 (40) Current (%) 100 1.573 (40) 1.612 (41) .830 (21.1) 1.172 (29.8) 1.967 (50) 20 30 40 50 60 70 Ambient Temperature (°C) 80 GREEN/YELLOW BROWN 90 Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 1 3 Filter 2 4 Oscillator 50Ω 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω 50Ω Level Meter 50Ω 60-BPL-010;-020 60-BPL-010;-020 80 80 60-BPL-020-5-X 60-BPL-010-X-4 70 70 60-BPL-010-X-2 60 50 60-BPL-010-5-X 40 60-BPL-010-3-X 30 20 Insertion Loss (dB) 60-BPL-020-3-X 60 50 60-BPL-020-X-4 40 30 60-BPL-020-X-2 20 10 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) Frequency (MHz) 60-BPL-030;-060 60-BPL-030;-060 80 80 60-BPL-030-X-4 60-BPL-030-5-X 70 70 60-BPL-030-3-X Insertion Loss (dB) 60 50 40 60-BPL-060-5-X 30 60-BPL-060-3-X 20 60 60-BPL-030-X-2 50 40 60-BPL-060-X-2 30 20 60-BPL-060-X-4 10 10 0 0.1 * General tolerance ±.012 (0.3) PVC Insulated wire UL1617 AWG #22 * Custom lengths available upon request. Common Mode 0 0.1 .236 (6) UL1015 AWG # 18 BLUE 1.160 (29.5) 1.573 (40) 0 Insertion Loss (dB) 4.719 (120)* .252 (6.4) 60 40 1.239 (31.5) Panel cutout dimensions mounts from front side .944 (24) 2- .142 (3.6) 20 Insertion Loss (dB) 2- .118 (M3) 2- .130 (3.3) Panel cutout dimensions mounts from back side 80 R3 .885 (22.5) .837 (21.3) 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF29 Power Entry Modules Snap-in Mount 60-SPR & SPS Series Features ■ ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Snap-in style saves labor and hardware inventory Solder lug and fast-on tab terminations available Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF33) UL approved low leakage version also available ■ ■ ■ Specifications Rated Voltage (@ 50/60Hz) Rated Current 60-XXX-010-3-2 60-XXX-010-3-4 250VAC E CY 2 4 Leakage Current (Max.) CY Capacitance 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 60-XXX-010-5-4 Temperature Rise (Max.) 6.0mH 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C .022uF ± 20% 0.26mH 45°C .1uF ± 20% 0.15mH 45°C .022uF ± 20% .022uF ± 20% .047uF ± 20% 60-XXX-020-3-2 0.35mA 250VAC 2200pF ± 20% .022uF ± 20% .047uF ± 20% 2A 60-XXX-020-5-2 0.50mA 3300pF ± 20% 60-XXX-020-5-4 .022uF ± 20% .047uF ± 20% 60-XXX-030-3-2 60-XXX-030-3-4 Inductance (L1) 0.35mA 250VAC .022uF ± 20% 2200pF ± 20% .047uF ± 20% 3A 60-XXX-030-5-2 0.50mA .022uF ± 20% 3300pF ± 20% 60-XXX-030-5-4 .047uF ± 20% 60-XXX-060-3-2 60-XXX-060-3-4 0.35mA 250VAC 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 60-XXX-060-5-4 .022uF ± 20% .047uF ± 20% 250VAC 10A 60-XXX-100-5-2 60-SPR-150-3-11 .022uF ± 20% .047uF ± 20% 6A 60-XXX-060-5-2 60-XXX-100-3-2 CX .047uF ± 20% 1A 60-XXX-010-5-2 60-XXX-020-3-4 CY L1 E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units Model* 3 1 CX Applications ■ Circuit Diagram 250VAC 15A Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 * Substitute SPR or SPS for XXX 60-SPR - Fast-on terminals 60-SPS - Solder lug terminals API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF32 Power Entry Modules Snap-in Mount 60-SPR & SPS Series R2 Temperature Characteristics .837 (21.3) .963 (24.5) 120 .853 (21.7) Panel cutout dimensions Current (%) 100 80 T: Panel Thickness T W .039 (1.0) 1.270 (32.3) .047 (1.2) 1.274 (32.4) .059 (1.5) 1.285 (32.5) 1.418 (35.9) .157 (4) 1.395 (35.5) * Standard terminal Fast-on tab #250 available as SPR series 2.096 (53.3) 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Solder lugs shown. Also available in fast-ons. Common Mode Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 60-SPX-010;-020;-030 50Ω 50Ω Level Meter 50Ω 60-SPX-010;-020;-030 80 80 70 70 60-SPX-010-5-X 60-SPX-010-X-4 Insertion Loss (dB) 60 50 40 60-SPX-020-5-X 30 60-SPX-030-5-X 20 10 60 50 60-SPX-020-X-4 40 60-SPX-030-X-4 30 20 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) Frequency (MHz) 60-SPX-060;-100 60-SPX-060;-100 80 80 70 70 Insertion Loss (dB) 60 60-SPX-60-5-X 50 40 30 60-SPX-100-5-X 20 10 0 0.1 Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 0 0.1 1.172 (29.8) * General tolerance ± .012 (0.3) 0 Insertion Loss (dB) Solder Lug 2 X 3 hole 40 20 Insertion Loss (dB) 1.805 (45.9) .252 (6.4) 60 W Panel cutout dimensions for 1.0t chassis 2.033 (51.7) 60-SPX-060-X-4 60 50 60-SPX-060-X-2 40 60-SPX-100-X-2 30 20 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF33 Fused Filtered Power Entry Modules For General Purpose Applications 64-65-BFF/64-65-BFS Series Features ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. North American and Metric fuse holders available Fuse holder provides effective EMI suppression of common and differential mode Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Fast-on terminals or solder lug terminals Metal case provides effective EMI shielding Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF35) ■ ■ ■ ■ L L L1 E R CY E CX CY Applications ■ Circuit Diagram N N Computers and peripheral equipment Electronic equipment Digital equipment Measuring and testing instruments Telecommunications equipment Specifications Model* 64-XXX-020-3-11 64-XXX-020-5-11 64-XXX-020-3-12 64-XXX-020-5-12 64-XXX-040-3-11 64-XXX-040-5-11 64-XXX-040-3-12 64-XXX-040-5-12 64-XXX-060-3-11 64-XXX-060-5-11 64-XXX-060-3-12 64-XXX-060-5-12 65-XXX-020-3-11 65-XXX-020-5-11 65-XXX-020-3-12 65-XXX-020-5-12 65-XXX-040-3-11 65-XXX-040-5-11 65-XXX-040-3-12 65-XXX-040-5-12 65-XXX-060-3-11 65-XXX-060-5-11 65-XXX-060-3-12 65-XXX-060-5-12 Rated Voltage (@ 50/60Hz) Rated Current 250VAC 2A 250VAC 250VAC 125VAC 125VAC 125VAC 4A 6A 2A 4A 6A Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC F(S) = Fast-on or (Solder lug terminals) Leakage Current (Max.) 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA CY 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF Capacitance ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% ± 20% Voltage Drop: 1V max. at rated current Weight: 78g Inlet: Compatible with IEC-320 CX Inductance (L1) Temperature Rise (Max.) 6.5mH 40°C 4.2mH 45°C 1.6mH 45°C 6.5mH 40°C 4.2mH 45°C 1.6mH 45°C 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF * Substitute BFF or BFS for XXX BFF - Fast-on terminals BFS - Solder lug terminals API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF34 Fused Filtered Power Entry Modules For General Purpose Applications 64-65-BFF/64-65-BFS Series 64/65-BFF Series Dimensions Temperature Characteristics 120 1.738 (44.2) 100 Current (%) 2.32 (59) .098 (2.5) 1.101 (28) Fuse cover 1.376 (35) 80 1.298 (33) 1.29 (32.8) 2 - .13 +.008 -.004 (2 - 3.3+0.2 -0.1) Hole 60 1.416±.008 (36±0.2) 0.252 (6.4) 1.14 (29) 1.616 (41.1) * Alternate Terminal for 64/65-BFS-Solder Lug Terminal 40 Fast-on tab#250 t= .031 (0.8) 20 0.158 (4.0) 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 * General Tolerance: ±.020 (0.5) * Metal Case 90 2.249 (L:57.2) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 0.50 mA Leakage Versions 50Ω 50Ω Level Meter 50Ω 0.50 mA Leakage Versions 90 90 80 80 2 Amp 70 2 Amp Insertion Loss (dB) Insertion Loss (dB) 70 60 50 40 6 Amp 30 20 60 50 6 Amp 40 4 Amp 30 20 4 Amp 10 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 0 0.1 50 0.35 mA Leakage Versions 90 90 80 80 2 Amp Insertion Loss (dB) Insertion Loss (dB) 0.5 1 2 5 Frequency (MHz) 10 20 50 10 20 50 0.35 mA Leakage Versions 70 70 60 50 40 6 Amp 30 2 Amp 60 50 40 6 Amp 30 4 Amp 20 20 4 Amp 10 10 0 0.1 0.2 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF35 Fused Filtered Power Entry Modules For Medical or General Purpose Applications ■ ■ ■ ■ ■ ■ Specifications Model* 66-XXX-020-1-11 66-XXX-020-1-12 66-XXX-020-0-11 66-XXX-020-4-11 66-XXX-020-0-12 66-XXX-020-4-12 66-XXX-040-1-11 66-XXX-040-1-12 66-XXX-040-0-11 66-XXX-040-4-11 66-XXX-040-0-12 66-XXX-040-4-12 66-XXX-060-1-11 66-XXX-060-1-12 66-XXX-060-0-11 66-XXX-060-4-11 66-XXX-060-0-12 66-XXX-060-4-12 67-XXX-020-1-11 67-XXX-020-1-12 67-XXX-020-0-11 67-XXX-020-4-11 67-XXX-020-0-12 67-XXX-020-4-12 67-XXX-040-1-11 67-XXX-040-1-12 67-XXX-040-0-11 67-XXX-040-4-11 67-XXX-040-0-12 67-XXX-040-4-12 67-XXX-060-1-11 67-XXX-060-1-12 67-XXX-060-0-11 67-XXX-060-4-11 67-XXX-060-0-12 67-XXX-060-4-12 Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) 0.01mA 250VAC 2A 0.075mA 0.1mA 0.075mA 0.1mA 0.01mA 250VAC 4A 0.075mA 0.1mA 0.075mA 0.1mA 0.01mA 250VAC 6A 0.075mA 0.1mA 0.075mA 0.1mA 0.005mA 125VAC 2A 0.035mA 0.05mA 0.035mA 0.05mA 0.005mA 125VAC 4A 0.035mA 0.05mA 0.035mA 0.05mA 0.005mA 125VAC 6A Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC F(S) = Fast-on or (Solder lug terminals) 0.035mA 0.05mA 0.035mA 0.05mA ■ ■ ■ ■ Medical equipment Electronic equipment Digital equipment Industrial equipment ■ ■ ■ Telecommunications equipment Measuring and testing instruments Personal computers and peripherals 66/67-BFF(S)-XXX-0-X and 66/67-BFF(S)-XXX-4-X Filters Circuit Diagrams 66/67-BFF(S)-XXX-1-X Filter L L L L L1 R L1 CX E E R CY CX E E LOAD ■ Applications LINE ■ Tested and found to be IAW VDE 0565 Part 3. Metric and North American fuse holders available Fuse holder provides effective EMI suppression of common and differential mode Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Fast-on terminations or solder lug terminations Metal case provides effective EMI shielding Provides susceptibility protection without the leakage current associated with line-to-ground capacitance Reduces the line to ground capacitance in order to meet patient care requirements Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF37) LOAD ■ LINE 66-67-BFF/66-67-BFS Series Features CY N N CY Capacitance none 330pF 470pF 330pF 470pF ± 20% ± 20% ± 20% ± 20% none 330pF 470pF 330pF 470pF ± 20% ± 20% ± 20% ± 20% none 330pF 470pF 330pF 470pF ± 20% ± 20% ± 20% ± 20% none 330pF 470pF 330pF 470pF ± 20% ± 20% ± 20% ± 20% none 330pF 470pF 330pF 470pF ± 20% ± 20% ± 20% ± 20% none 330pF 470pF 330pF 470pF ± 20% ± 20% ± 20% ± 20% Voltage Drop: 1V max. at rated current Weight: 78g Inlet: Compatible with IEC-320 CX 0.1uF 0.22uF 0.1uF N N Inductance (L1) Temperature Rise (Max.) 6.5mH 40°C 2.4mH 45°C 1.6mH 45°C 6.5mH 40°C 2.4mH 45°C 1.6mH 45°C 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF * Substitute BFF or BFS for XXX BFF - Fast-on terminals BFS - Solder lug terminals API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF36 Fused Filtered Power Entry Modules For Medical or General Purpose Applications 66-67-BFF/66-67-BFS Series 66-67-BFF/66-67-BFS Series Dimensions Temperature Characteristics 120 1.738 (44.2) 2.32 (59) .098 (2.5) 1.101 (28) 100 Current (%) Fuse cover 1.376 (35) 80 1.298 (33) 60 1.416±.008 (36±0.2) 40 1.29 (32.8) 2 - .13 +.008 -.004 (2 - 3.3+0.2 -0.1) Hole 0.252 (6.4) 1.14 (29) 1.616 (41.1) * Alternate Terminal for 66/67-BFS-Solder Lug Terminal Fast-on tab#250 t= .031 (0.8) 20 0.158 (4.0) 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 2.249 (L:57.2) Common Mode Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 90 90 80 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 50Ω 60 2 Amp 40 30 60 2 Amp 50 30 0 0.1 0.2 0.5 10 1 2 5 Frequency (MHz) 10 20 0 0.1 50 80 80 70 70 Insertion Loss (dB) 90 60 2 Amp 50 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0.075 and 0.1 mA Leakage Current 0.075 and 0.1 mA Leakage Current 90 40 30 60 2 Amp 50 40 30 20 20 6 Amp 4 Amp 10 0 0.1 6 Amp 6 Amp 4 Amp 4 Amp 40 20 20 10 50Ω Level Meter 50Ω 0.01 mA Leakage Current 0.01 mA Leakage Current Insertion Loss (dB) Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 50 * General Tolerance: ±.020 (0.5) * Metal Case 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 6 Amp 4 Amp 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF37 Switched and Fused Filtered Power Entry Modules For General Purpose Applications 64-65-BSF/64-65-SSF Series Features ■ ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. North American and Metric fuse holders available Fuse holder and double pole power ON/OFF switch provided in a convenient/compact package Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Metal case provides effective EMI shielding Easy access fuse drawer with space for spare fuse Flange-mounted or snap-in styles available for quick mounting Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF39) Specifications Model* Rated Voltage (@ 50/60Hz) Rated Current 64-XXX-020-3-12 64-XXX-020-3-04 64-XXX-020-3-14 64-XXX-020-3-06 250VAC 2A 64-XXX-020-5-12 64-XXX-020-5-04 64-XXX-020-5-14 64-XXX-020-5-06 64-XXX-040-3-12 64-XXX-040-3-04 64-XXX-040-3-14 64-XXX-040-3-06 250VAC 4A 64-XXX-040-5-12 64-XXX-040-5-04 64-XXX-040-5-14 64-XXX-040-5-06 64-XXX-060-3-12 64-XXX-060-3-04 64-XXX-060-3-14 64-XXX-060-3-06 250VAC 6A 64-XXX-060-5-12 64-XXX-060-5-04 64-XXX-060-5-14 64-XXX-060-5-06 65-XXX-020-3-12 65-XXX-020-3-04 65-XXX-020-3-14 65-XXX-020-3-06 125VAC 2A 65-XXX-020-5-12 65-XXX-020-5-04 65-XXX-020-5-14 65-XXX-020-5-06 65-XXX-040-3-12 65-XXX-040-3-04 65-XXX-040-3-14 65-XXX-040-3-06 125VAC 4A 65-XXX-040-5-12 65-XXX-040-5-04 65-XXX-040-5-14 65-XXX-040-5-06 65-XXX-060-3-12 65-XXX-060-3-04 65-XXX-060-3-14 65-XXX-060-3-06 125VAC 6A 65-XXX-060-5-12 65-XXX-060-5-04 65-XXX-060-5-14 65-XXX-060-5-06 Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC B(S) = Bolt-in terminals or (Snap-in terminals) Applications ■ ■ Computers and peripheral equipment Electronic equipment L L CY CX E N N 2200pF Capacitance CX1 0.22uF 0.47uF 0.22uF 3300pF 0.47uF 0.22uF 2200pF 0.47uF 0.22uF 3300pF 0.47uF 0.22uF 0.35mA 2200pF 0.47uF 0.22uF 0.50mA 3300pF 0.47uF 0.22uF 0.20mA 2200pF 0.47uF 0.22uF 0.25mA 3300pF 0.47uF 0.22uF 0.20mA 2200pF 0.47uF 0.22uF 0.25mA 3300pF 0.47uF 0.22uF 0.20mA 2200pF 0.47uF 0.22uF 0.25mA E CY 0.35mA 0.50mA CX R CY 0.35mA ■ Digital equipment Measuring and testing instruments Telecommunications equipment Circuit Diagram Leakage Current (Max.) 0.50mA ■ ■ 3300pF 0.47uF Voltage Drop: 1V max. at rated current Weight: 130g Inlet: Compatible with IEC-320 CX2 Inductance (L1) NONE 0.22uF NONE 10.5mH 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 10.5mH NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF * Substitute BSF or SSF for XXX BSF - Bolt-in switched and fused SSF - Snap-in switched and fused Temperature Rise (Max.) 45°C 45°C 45°C 45°C 45°C 45°C API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF38 Temperature Temperature Characteristics Characteristics 120 Current (%) 100 Switched and Fused Filtered Power Entry Modules For General Purpose Applications 80 60 40 20 0 64/65-SSF Series 64/65-BSF Series Dimensions 1.947 (49.5) 1.101 (28) 20 1.313 (33.4) 1.101 (28) .248 (6.3) 30 40 50 60 70 Ambient Temperature (°C) .248 (6.3) 80 90 1.133 (28.8) 1.514 (38.8) 1.526 (38.8) Fast-on tab #250 t= .031 (0.8) 2.556 (65) 2.556 (65) 2.340 (59.5) 2.348 (59.7) 2.348 (59.7) 2.340 (59.5) Ø.142 (3.6) R .079 (2.0) 2 - .142 (3.6) Hole R .059 (1.5) A t= .031 (0.8) Panel cutout dimension mount from back side 1.573 1.16±.334 0 (40.±0.2) (29.5± 0.5) 0 Thickness of Panel .031 (0.8t) .039 (1.0t) .047 (1.2t) .059 (1.5t) .071 (1.8t) .079 (2.0t) 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 1.573 (40±0.2) 2.273 (57.8) Dimensions in inches (mm) Panel cutout dimension mount from back side 1.16 +.02 -0 (29.5 +0.5 -0 ) A 2.430 (61.8±0.1) 2.446 (62.2±0.1) 2.462 (62.6±0.1) 2.470 (62.8±0.1) 2.473 (62.9±0.1) 2.477 (63.0±0.1) * General Tolerance ± .039 (1.0) * Metal Case 2.399 (61) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 50Ω 1 3 Filter 2 4 50Ω Level Meter Oscillator 50Ω 0.35 mA Leakage Versions 100 80 90 70 80 2 Amp Insertion Loss (dB) Insertion Loss (dB) 50Ω Level Meter 50Ω 64/65-B(S)SF-*-*-02(04,06) 90 60 50 40 4 Amp 30 6 Amp 20 70 60 50 2 Amp 40 4 Amp 30 10 6 Amp 20 0 0.1 0.2 1 0.5 2 5 Frequency (MHz) 10 20 0 0.1 50 0.50 mA Leakage Versions 0.5 1 2 5 Frequency (MHz) 10 20 50 20 50 100 80 90 70 80 Insertion Loss (dB) 2 Amp 60 50 40 4 Amp 30 6 Amp 20 70 60 4 Amp 6 Amp 50 2 Amp 40 30 10 0 0.1 0.2 64/65-B(S)SF-*-*-11(12,14) 90 Insertion Loss (dB) 50Ω 20 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF39 Switched and Fused Filtered Power Entry Modules For Medical or General Purpose Applications 66-67-BSF/66-67-SSF Series Features Tested and found to be IAW VDE 0565 Part 3 Metric and North American fuse holders available Fuse holder and a double pole power ON/OFF switch provides a convenient/compact package ■ Suitable for products that must conform to FCC and FTZ requirements ■ Meets over voltage category II of IEC 664 and complies with IEC 950 ■ Provides susceptibility protection without the leakage current associated with line-to-ground capacitors ■ Designed to meet requirements for non-patient and patient care equipment ■ Metal case provides effective EMI shielding ■ Easy access fuse drawer - space for spare fuse ■ Flange-mounted or snap-in styles available for quick mounting ■ Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF41) ■ ■ Specifications Model* 66-XXX-020-0-12 66-XXX-020-0-04 66-XXX-020-0-14 66-XXX-020-0-06 66-XXX-020-1-12 66-XXX-020-1-04 66-XXX-020-1-14 66-XXX-020-1-06 66-XXX-020-4-12 66-XXX-020-4-04 66-XXX-020-4-14 66-XXX-020-4-06 66-XXX-040-0-12 66-XXX-040-0-04 66-XXX-040-0-14 66-XXX-040-0-06 66-XXX-040-1-12 66-XXX-040-1-04 66-XXX-040-1-14 66-XXX-040-1-06 66-XXX-040-4-12 66-XXX-040-4-04 66-XXX-040-4-14 66-XXX-040-4-06 66-XXX-060-0-12 66-XXX-060-0-04 66-XXX-060-0-14 66-XXX-060-0-06 66-XXX-060-1-12 66-XXX-060-1-04 66-XXX-060-1-14 66-XXX-060-1-06 66-XXX-060-4-12 66-XXX-060-4-04 66-XXX-060-4-14 66-XXX-060-4-06 Rated Rated Leakage Voltage Current Current Capacitance 50/60Hz (Max.) CY CX1 CX2 0.22uF .075mA 330pF 0.47uF 0.22uF 2A .01mA NONE 0.47uF 0.22uF 0.1mA 470pF 0.47uF 0.22uF .075mA 330pF 0.47uF 250 VAC 0.22uF 4A .01mA NONE 0.47uF 0.22uF .01mA 470pF 0.47uF 0.22uF .075mA 330pF 0.47uF 0.22uF 6A .01mA NONE 0.47uF 0.22uF 0.1mA 470pF 0.47uF Temp. Induct. (L1) Applications ■ ■ ■ ■ ■ ■ Digital equipment (including switching power supplies) General purpose filter for susceptibility or high frequency “clean up” applications Circuit Diagram L L CX1 CX2 CY1 E E LOAD L1 R LINE Note: CY1 and CY2 capacitors omitted on 66/67 B(S)F-XXX-1-X Filters CY2 N N Rise (Max.) NONE 0.22uF NONE 0.22uF NONE 0.22uF 10.5mH 40°C NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF 45°C NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF NONE 0.22uF Note: Test Voltage: 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC Voltage Drop: 1V max. at rated current Medical equipment Industrial equipment Telecommunications equipment Measuring and testing instruments Model* 67-XXX-020-0-12 67-XXX-020-0-04 67-XXX-020-0-14 67-XXX-020-0-06 67-XXX-020-1-12 67-XXX-020-1-04 67-XXX-020-1-14 67-XXX-020-1-06 67-XXX-020-4-12 67-XXX-020-4-04 67-XXX-020-4-14 67-XXX-020-4-06 67-XXX-040-0-12 67-XXX-040-0-04 67-XXX-040-0-14 67-XXX-040-0-06 67-XXX-040-1-12 67-XXX-040-1-04 67-XXX-040-1-14 67-XXX-040-1-06 67-XXX-040-4-12 67-XXX-040-4-04 67-XXX-040-4-14 67-XXX-040-4-06 67-XXX-060-0-12 67-XXX-060-0-04 67-XXX-060-0-14 67-XXX-060-0-06 67-XXX-060-1-12 67-XXX-060-1-04 67-XXX-060-1-14 67-XXX-060-1-06 67-XXX-060-4-12 67-XXX-060-4-04 67-XXX-060-4-14 67-XXX-060-4-06 Rated Rated Leakage Voltage Current Current Capacitance 50/60Hz (Max.) CY CX1 CX2 0.22uF 0.04mA 330pF 0.47uF 0.22uF 2A .005mA NONE 0.47uF 0.22uF 0.05mA 470pF 0.47uF 0.22uF 0.04mA 330pF 0.47uF 125 VAC 0.22uF 4A .005mA NONE 0.47uF 0.22uF 0.05mA 470pF 0.47uF 0.22uF 0.04mA 330pF 0.47uF 0.22uF 6A Weight: 130g Inlet: Compatible with IEC-320 B(S) = Bolt-in terminals or (Snap-in terminals) .005mA NONE 0.47uF 0.22uF 0.05mA 470pF 0.47uF Temp. Induct. (L1) Rise (Max.) NONE 0.22uF NONE 0.22uF NONE 0.22uF 10.5mH 40°C NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF 45°C NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF NONE 0.22uF * Substitute BSF or SSF for XXX BSF - Bolt-In Switched and Fused SSF - Snap-In Switched and Fused API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF40 Temperature Characteristics 120 Current (%) 100 Switched and Fused Filtered Power Entry Modules For Medical or General Purpose Applications 80 60 40 20 0 66/67-BSF Series .248 (6.3) 1.313 (33.4) 1.101 (28) 1.526 (38.8) 2.556 (65) .248 (6.3) 2.340 (59.5) Ø.142 (3.6) 2 - .142 (3.6) Hole R .059 (1.5) 2.340 (59.5) 2.348 (59.7) R .079 (2.0) Dimensions in inches (mm) Common Mode 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 80 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 90 60 2 Amp 40 30 2 Amp 50 40 30 4 Amp 6 Amp 10 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 0 0.1 50 90 80 80 70 70 Insertion Loss (dB) 90 60 2 Amp 50 40 30 20 1 2 5 Frequency (MHz) 10 20 50 2 Amp 60 50 40 4 Amp 30 6 Amp 10 10 0 0.1 0.5 20 6 Amp 4 Amp 0.2 0.075 and 0.1 mA Leakage Current 0.075 and 0.1 mA Leakage Current Insertion Loss (dB) 50Ω Level Meter 50Ω 60 20 6 Amp 4 Amp 50Ω 0.01 mA Leakage Current 0.01 mA Leakage Current 90 20 * General Tolerance ± .039 (1.0) * Metal Case Panel cutout dimension mount from back side 1.16 +.02 -0 (29.5 +0.5 -0 ) A 2.430 (61.8±0.1) 2.446 (62.2±0.1) 2.462 (62.6±0.1) 2.470 (62.8±0.1) 2.473 (62.9±0.1) 2.477 (63.0±0.1) Normal Mode 1 3 Filter 2 4 50 Thickness of Panel .031 (0.8t) .039 (1.0t) .047 (1.2t) .059 (1.5t) .071 (1.8t) .079 (2.0t) A 2.399 (61) Oscillator 50Ω 2.273 (57.8) t= .031 (0.8) Panel cutout dimension mount from back side 1.573 1.16 +.02 -0 (40.±0.2) (29.5 +0.5) -0 90 Fast-on tab #250 t= .031 (0.8) 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 1.573 (40±0.2) 80 1.133 (28.8) 1.514 (38.8) 2.556 (65) 2.348 (59.7) 30 40 50 60 70 Ambient Temperature (°C) 66/67-SSF Series Dimensions 1.947 (49.5) 1.101 (28) 20 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF41 Switched and Fused Filtered Power Entry Modules Dual Fuse for European Applications 68-BSF Series Features Dual fuse for European applications Fuse holder and double pole power ON/OFF switch provides a convenient/compact package ■ Suitable for products that must conform to FCC and FTZ requirements ■ Meets over voltage category II of IEC 664 and complies with IEC 950 ■ Metal case provides effective EMI shielding ■ IEC connector meets the safety standards of most certifying agencies ■ Easy access fuse drawer ■ Flange-mounted ■ UL, CSA, and SEMKO approved ■ Designed to be in accordance with VDE 0565, part 3 ■ Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF43) ■ ■ Circuit Diagram FUSE L L L1 CX2 CX1 E CY1 E R1 L2 CY2 N N SW Applications Computers and peripheral equipment Electronic equipment ■ Digital equipment ■ Measuring and testing instruments ■ Telecommunications equipment ■ ■ Specifications Model Rated Voltage (@ 50/60Hz) 68-BSF-020-3-01 Rated Current Leakage Current (Max.) CY1 Capacitance CY2 CX1 2A 68-BSF-020-3-04 68-BSF-040-3-01 250VAC 4A 68-BSF-040-3-04 68-BSF-060-3-01 6A 68-BSF-060-3-04 0.35mA 2200pF 2200pF CX2 0.1uF 0.1uF 0.22uF 0.22uF 0.1uF 0.1uF 0.22uF 0.22uF 0.1uF 0.1uF 0.22uF 0.22uF Inductance (L1) Temperature Rise (Max.) 10.5mH 4.2mH 45°C 1.6mH Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC Voltage Drop: 1V max. at rated current Weight: 130g Inlet: Compatible with IEC-320 B(S) = Bolt-in terminals API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF42 Switched and Fused Filtered Power Entry Modules Dual Fuse for European Applications 68-BSF Series Temperature Characteristics 1.947 (49.5) 1.101 (28) .248 (6.3) 1.526 (38.8) 120 2.556 (65) Current (%) 100 80 2.348 (59.7) 60 2 - .142 (3.6) Hole 20 30 40 50 60 70 Ambient Temperature (°C) 80 Dimensions in inches (mm) 2.399 (61) Normal Mode 1 3 Filter 2 4 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 90 50Ω 50Ω Level Meter 50Ω 100 90 70 80 Insertion Loss (dB) 80 60 50 40 4 Amp 30 2 Amp 6 Amp 20 70 4 Amp 60 50 2 Amp 40 30 10 0 0.1 t= .031 (0.8) 90 Common Mode Oscillator 50Ω R .059 (1.5) Panel cutout dimension mount from back side 1.573 1.16 +.02 -0 (40.±0.2) (29.5 +0.5) -0 0 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 1.573 (40±0.2) 40 20 Insertion Loss (dB) 2.340 (59.5) Ø.142 (3.6) 6 Amp 20 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF43 PCB Power Filters Miniature Printed Circuit Board 61-MPC Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ Miniature general purpose PCB mounted filter Requires minimal PCB real estate space Low cost Designed for two wire cord systems For three wire cord systems, Y capacitors can be attached externally Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF45) Circuit Diagram 3 1 Applications ■ ■ ■ ■ ■ L1 Personal computers and peripherals Digital equipment Measuring instruments and medical equipment TV & VCR monitors and display units Home appliances CX1 CX1 2 Specifications Model Rated Voltage (@ 50/60Hz) 61-MPC-010-1-11 61-MPC-016-1-11 61-MPC-025-1-11 61-MPC-036-1-11 Rated Current Leakage Current (Max.) CX1 4 Capacitance CX2 1A 250VAC 1.6A 2.5A 3.6A Inductance (L1) Temperature Rise (Max.) 11mH 0.1mA 0.1uF 0.1uF 6.0mH 2.4mH 40°C 1.2mH Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 17.5g API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF44 PCB Power Filters Miniature Printed Circuit Board 61-MPC Series 4 3 4 — .031 (.8) .551 (14) 2 1 .767 (19.5) .059 (1.5) 1.239 (31.5) .767 (19.5) .590 (15) .354 (9) Dimensions in inches (mm) Temperature Characteristics Common Mode 1 3 Filter 2 4 Oscillator 50Ω 100 50Ω Level Meter 50Ω 1 3 Filter 2 4 (Test circuit 2) Oscillator 50Ω Current (%) Common mode with Y cap. (Test circuit 1) 120 50Ω Level Meter 50Ω 80 60 40 20 0 0 30 40 50 60 70 80 Ambient Temperature (°C) 90 100 61-MPC 80 Y Cap 2 X 3300pF 70 Insertion Loss (dB) 61-MPC-010-1-11 Normal Mode 60 50 1 3 Filter 2 4 40 (Test circuit 3) 61-MPC-016-1-11 30 61-MPC-025-1-11 Oscillator 50Ω 20 50Ω 50Ω Level Meter 50Ω 61-MPC-036-1-11 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 61-MPC 61-MPC 80 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 61-MPC-010-1-11 50 40 30 61-MPC-016-1-11 20 0.5 1 61-MPC-010-1-11 40 61-MPC-016-1-11 30 61-MPC-025-1-11 20 10 61-MPC-036-1-11 0.2 50 61-MPC-036-1-11 61-MPC-025-1-11 10 0 0.1 60 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF45 Power Entry Modules Bolt-in Right Angle Terminals for PCB Applications 60-BPP Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ ■ Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Solder lug, Fast-on tab styles available (see page PF18) PCB mounting style minimizes space and provides economical installation Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF47) UL approved low leakage version also available Applications ■ ■ ■ ■ Model Rated Voltage (@ 50/60Hz) Rated Current CX E 2 4 Leakage Current (Max.) CY Capacitance 0.35mA 2200pF 0.50mA 3300pF 60-BPP-020-3-2 0.35mA 60-BPP-020-3-4 2200pF Temperature Rise (Max.) 0.022uF 6.0mH 0.022uF 0.022uF 0.047uF 2A 60-BPP-020-5-2 0.50mA 3300pF 2.4mH 30°C 0.022uF 0.047uF 250VAC 60-BPP-030-3-2 0.35mA 2200pF 0.022uF 0.047uF 3A 60-BPP-030-5-2 0.50mA 3300pF 0.047uF 60-BPP-060-3-2 0.022uF 0.35mA 2200pF 0.047uF 6A 60-BPP-060-5-2 60-BPP-060-5-4 0.50mA 3300pF 1.2mH 0.022uF 60-BPP-030-5-4 60-BPP-060-3-4 Inductance (L1) 0.047uF 60-BPP-010-5-4 60-BPP-030-3-4 CX 0.047uF 1A 60-BPP-010-5-2 60-BPP-020-5-4 CY L1 CY 60-BPP-010-3-2 60-BPP-010-3-4 3 1 E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units Specifications Circuit Diagram 0.53mH 45°C 0.022uF 0.047uF Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF46 Power Entry Modules Bolt-in Right Angle Terminals for PCB Applications 60-BPP Series 60-BPP PCB Mounting Type Temperature Characteristics 120 Current (%) 100 .098 (2.5) 1.463 (37.2) 1.967 (50) 1.317 (33.5) 1.573 (40) .885 (22.5) 2- .142 (3.6) 80 .047 (1.2) .232 (5.9) 60 .024 (.6) .5 R4 .865 (22) 40 2- .142 (3.6) 1.573 (40) * General tolerance ± .012 (.3) .142 .059 (3.6) (1.5) .031 (.8) 1.070 (27.2) 1.180 (30) .779 1.180 (19.8) (30) .708 (18) Panel cutout dimensions mounts from backside 20 0 .991 (25.2) .590 (15) 20 30 40 50 60 70 Ambient Temperature (°C) 80 Dimensions in inches (mm) 90 Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 50Ω 50Ω Level Meter 50Ω 60-BPP-010;-020 60-BPP-010;-020 80 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 60-BPP-010-3-X 50 60-BPP-020-3-X 40 30 20 60 60-BPP-010-X-4 50 40 30 60-BPP-020-X-4 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 5 10 20 50 20 50 60-BPP-030;-060 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 60-BPP-030;-060 80 60-BPP-030-3-X 50 40 60-BPP-060-3-X 30 20 10 0 0.1 2 Frequency (MHz) Frequency (MHz) 60 50 40 60-BPP-030-X-4 30 60-BPP-060-X-4 20 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF47 Power Entry Modules High Frequency Attenuation Bolt-in for PCB Applications 60-BHP Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ ■ ■ Ideally suited for products that must conform to FCC part 15 regulations Metal cased filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Solder lug, Fast-on tab styles available (see page PF20) PCB mounting minimizes space and provides economical installation Excellent filtering characteristics for high frequencies Earth coil standard Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF49) Circuit Diagram ■ ■ ■ CX Model Rated Voltage (@ 50/60Hz) Rated Current 60-BHP-010-3-11 CY 2 Leakage Current (Max.) CY Capacitance 2200pF±20% 0.50mA 3300pF±20% 60-BHP-010-5-4 0.35mA 60-BHP-020-3-4 2200pF±20% 0.50mA 3300pF±20% 0.35mA 2200pF±20% 0.1uF±20% 2.4mH 0.50mA 3300pF±20% 60-BHP-030-5-4 30°C 0.1uF±20% 18.3 uH 0.1uF±20% .047uF±20% 3A 60-BHP-030-5-11 1.2mH 0.1uF±20% .047uF±20% 60-BHP-060-3-11 60-BHP-060-5-11 6mH 0.1uF±20% .047uF±20% 250VAC 60-BHP-030-3-11 60-BHP-060-3-4 Temperature Rise (Max.) 0.1uF±20% .047uF±20% 2A 60-BHP-020-5-11 60-BHP-030-3-4 Inductance (L1) (L2) .047uF±20% 60-BHP-020-3-11 60-BHP-020-5-4 CX .047uF±20% 1A 60-BHP-010-5-11 4 L2 0.35mA 60-BHP-010-3-4 E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units Specifications CY L1 Applications ■ 3 1 0.35mA 2200pF±20% 0.1uF±20% .047uF±20% 6A 0.50mA 60-BHP-060-5-4 3300pF±20% 0.53mH 45°C 0.1uF±20% .047uF±20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF48 Power Entry Modules High Frequency Attenuation Bolt-in for PCB Applications 60-BHP Series 60-BHP PCB Mounting Type Temperature Characteristics 120 Current (%) 100 .098 (2.5) 1.967 (50) 1.573 (40) .885 (22.5) .991 (25.2) .590 (15) 2- .142 (3.6) 5 4. 2- .142 (3.6) 1.573 (40) 40 .059 (1.5) .031 (.8) 1.070 (27.2) .024 (.6) R .865 (22) .142 (3.6) .047 (1.2) .232 (5.9) 1.180 (30) 80 60 1.534 (39) 1.389 (35.3) .779 1.180 (19.8) (30) .708 (18) Panel cutout dimensions mounts from backside 20 Dimensions in inches (mm) 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 90 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 60-BHP-XXX-X-11 90 80 Insertion Loss (dB) Insertion Loss (dB) 60-BHP-020-X-11 50 40 60-BHP-030-X-11 30 60-BHP-060-X-11 60-BHP-010-3-11 60 50 60-BHP-020-3-11 40 60-BHP-030-3-11 30 60-BHP-060-3-11 20 10 10 0.2 1 0.5 2 5 10 20 0 0.1 50 60-BHP-XXX-X-4 Frequency (MHz) 90 90 60-BHP-010-X-4 70 Insertion Loss (dB) Insertion Loss (dB) 0.2 0.5 1 60-BHP-XXX-3-4 2 5 10 20 50 Frequency (MHz) 80 80 60-BHP-020-X-4 60 50 40 60-BHP-030-X-4 30 60-BHP-060-X-4 70 60-BHP-010-3-4 60 50 60-BHP-020-3-4 40 60-BHP-030-3-4 30 60-BHP-060-3-4 20 20 10 10 0 0.1 60-BHP-XXX-3-11 70 20 0 0.1 50Ω Level Meter 50Ω 80 60-BHP-010-X-11 70 60 50Ω 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF49
60-BPP-010-5-4
物料型号: - 60-BPR & BPS Series - 60-BPF Series - 60-BHS Series - 60-SPL Series - 60-BPL Series - 60-SPR & SPS Series - 64-65-BFF/64-65-BFS Series - 66/67-BFF(S)-XXX-X Series - 64-65-BSF/64-65-SSF Series - 68-BSF Series - 61-MPC Series - 60-BPP Series - 60-BHP Series

器件简介: 这些电源入口模块适用于需要遵守FCC第15部分规定的产品,提供高性能的金属外壳滤波器,满足IEC 664第二类过电压要求,并符合IEC 950标准。

引脚分配: 文档中未明确提供具体的引脚分配图,但提到了多种安装方式,如螺栓安装、焊接和快接端子等。

参数特性: - 额定电压(@50/60Hz) - 额定电流 - 最大漏电流 - 电容(Cy, Cx) - 电感(L1, L2) - 温度上升(最大值)

功能详解: 这些模块提供了针对高频衰减的过滤特性,适用于数字设备、个人电脑及其外围设备、测量仪器、监控和显示单元等。部分模块还特别适用于医疗设备或需要低漏电流的应用。

应用信息: - 数字设备 - 个人电脑及其外围设备 - 测量仪器 - 监控和显示单元 - 医疗设备 - 工业设备 - 电信设备

封装信息: 提供了多种封装类型,包括螺栓安装、快接端子、焊接端子等,以适应不同的安装需求。还提供了一些特定系列的尺寸信息,如60-BPP系列和60-BHP系列的面板开口尺寸。
60-BPP-010-5-4 价格&库存

很抱歉,暂时无法提供与“60-BPP-010-5-4”相匹配的价格&库存,您可以联系我们找货

免费人工找货