Technical Data Sheet for NL1025T
Single-Stage Thermoelectric Module
NOMINAL PERFORMANCE IN NITROGEN
Hot Side Temperature (°C)
Δ Tmax (°C):
Qmax (watts):
Imax (amps):
Vmax (vdc):
AC Resistance (ohms):
PRODUCT FEATURES
27
64
5.2
1.8
4.4
2.1
50
73
5.8
1.8
4.9
--
ORDERING OPTIONS
RoHS EU Compliant
Rated operating temperature of 85°C
Maximum processing temperature of 220°C
Ceramic Material: Aluminum Oxide.
Model Number
NL1025T-01AC
NL1025T-02AC
NL1025T-03AC
NL1025T-05AC
NL1025T-06AC
NL1025T-07AC
Description
Both Surfaces are Metallized
Hot Side Exterior is Metallized
No Metallization
No Metallization, Insulated 7 Inch
Leadwire
No Metallization, RTV Sealed
No Metallization, Insulated 5 Inch
Leadwire
OPERATION CAUTIONS
INSTALLATION
For maximum reliability, storage and operation below
85°C in a non-condensing environment is recommended.
To minimize thermal stress, use linear/proportional
temperature control or a similar method rather than an
ON/OFF method.
Recommended mounting methods: Bonding with thermal
epoxy or soldering with metallized ceramics. For additional
information, please refer to our TEM Installation Guide.
II-VI Marlow – Dallas, TX USA
214-340-4900
877-627-5691
marlow.sales@ii-vi.com
Marlow Industries Europe
GmbH - Germany
+49 (0) 6150 5439 - 403
info@marlow-europe.eu
II-VI Japan Inc.
81 43 297 2693 (tel)
center@ii-vi.co.jp
www.ii-vi.co.jp
MI Form 005-0808 Rev. B
II-VI Singapore Pte., Ltd.
(65) 6481 8215 (tel)
info@ii-vi.com.sg
Marlow Industries China, II-VI
Technologies Beijing
86-10-643 98226
info@iivibj.com
DOC # 102-0298 REV P - PAGE 1 OF 2
www.marlow.com
Hot Side Temperature 27°C
40.0
20.0
0.0
60.0
40.0
20.0
0.0
4.0
Q=0
T=0
2.0
1.0
VOLTAGE (VDC)
5.0
3.0
0.0
0.0
HEAT
LOAD
(WATTS)
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
5.50
80.0
T (C)
60.0
T (C)
Hot Side Temperature 50°C
HEAT
LOAD
(WATTS)
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
80.0
VOLTAGE (VDC)
TYPICAL PERFORMANCE CURVES
ENVIRONMENT: ONE ATMOSPHERE DRY NITROGEN
4.0
3.0
Q=0
T=0
2.0
1.0
0.4
0.8
1.2
CURRENT (AMPS)
1.6
0.0
0.0
2.0
0.4
0.8
1.2
CURRENT (AMPS)
1.6
2.0
MECHANICAL CHARACTERISTICS
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, contact one of our Applications Engineers at 877-627-5691.
All units are in inches and [ ] are in millimeters unless otherwise stated.
For customer support or general questions please contact a local office or visit our website at www.marlow.com.
Marlow reserves the right to make product changes without notice.
MI Form 005-0808 Rev. B
DOC # 102-0298 REV P - PAGE 2 OF 2
www.marlow.com